High Pressure, Subplate Mounted Directional Control Valves

Similar documents
High Pressure, Subplate Mounted Directional Control Valves

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

Directional Control Valves. General Description. Operation. Features

Directional Control Valves. Features. Application. Operation

Directional Control Valves Series D81V. General Description. Operation. Features. Specifications

Directional Control Valves. Application. Features. Operation. D3W Solenoid Operated Conduit Cavity Style. D3W Solenoid Operated Hirschmann (DIN) Style

Directional Control Valves. General Description. Operation. Features

Directional Control Valves. Application. Features. Operation

Directional Control Valves. General Description. Operation. Features

Hydraulics 1. Directional Control Valves Series D1M. Features. Application. Operation. D1MW Solenoid Operated Free Lead Wire

Directional Control Valves. Application. Features. Operation.

Directional Control Valves. Application. Features. Operation

Operation. D1VW Solenoid Operated Plug-In Conduit Box Style

Pilot Operated Directional Valves

Operation. D1VW Solenoid Operated Plug-In Conduit Box Style

Operation. D1VW Solenoid Operated Plug-In Conduit Box Style

D07 & D08. Series 35 Solenoid Valves D07 D Friendship Drive, Magnolia, TX Tel.: Fax:

Directional Control Valves. Features. Application. Operation

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Directional Controls

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Directional Control Valves

Directional Controls

Bar 35 PSI 500. Pressure Drop L/M GPM. Flow

Directional Control Valves. Features. Application. Operation

Operation. D3W Solenoid Operated Conduit Box Style. D3W Solenoid Operated Hirschmann (DIN) Style

p max (see table of performances) Q max (see table of performances) MD1K MD1KD bar

Directional Controls

IFP DG08 SOLENOID CONTROLLED PILOT OPERATED DIRECTIONAL VALVE SIZE NG22/CETOP08

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Industrial Hydraulic Valves. Directional Control, Pressure Control, Sandwich, Subplates & Manifolds, Accessories. Catalog HY /US

Série D3 Válvula Direcional CETOP 5 e NG 10. Catálogo HY /US

Directional control valves NG6...NG32 D03...D10 6

45 lpm. Part Number Spool Qty Max Flow Max Pressure Ports. 45 lpm. Relief Valve Standard Bar Range Power Beyong Plug included in every kit

Pilot Operated Directional Valves

YOULI HYDRAULIC INDUSTRIAL CO.,LTD.

YOULI HYDRAULIC INDUSTRIAL CO.,LTD.

Monobloc and Sectional Directional Control Valves

IFP DG07 SOLENOID CONTROLLED PILOT OPERATED DIRECTIONAL VALVE SIZE NG-16 / CETOP-07

DFE10. solenoid control monoblock valve. Ordering codes. Description example : Diverter valve DFE10/3 A 18 ES - W VDC - SAE - <CVN>

DIRECTIONAL VES. Components For The Control Of A Wide Range Of Operating Flows And Pressures

CTSN-4 Content Sectional Directional Control Valves

YOULI HYDRAULIC INDUSTRIAL CO.,LTD.

Bankable Control Valves

Part Number Spool Qty Max Flow Max Pressure Ports. 80 lpm

YOULI HYDRAULIC INDUSTRIAL CO.,LTD.

MB-4 Chapters Monoblock Directional Control Valves

Directional Control Valves. General Description. Features. Specifications

EManually Operated Directional Valves

Directional Control Valves Series D111VW. General Description. Features. Performance Curves

Directional Controls

Rexroth Hydraulics. Servo directional valve of 4-way design Type 4WS.2EM RE /03.99

MB-2 Chapters Monoblock Directional Control Valves

ANTI-SHOCK DIRECTIONAL CONTROL VALVES

Directional Control Valves

Monobloc and Sectional Directional Control Valves

Proportional Directional Valve System

MDT. Monoblock directional control valves MDT - Directional control valve

Hydro M t HYDRAULIC VALVES SN-4.

4/2- and 4/3-Way Proportional Directional Control Valve Direct Operated, Model 4 WRA (Series 1X) PSI (315 bar) H/A 1768

"G" SERIES SHOCKLESS TYPE SOLENOID OPERATED DIRECTIONAL VALVES G-DSG-01/03 (1/8, 3/8) "G" SERIES SHOCKLESS TYPE

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

Solenoid valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm)

Solenoid Valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) A-1.

Accessories. Subplates and Connection Plates for Four-Port Directional Valves. Vickers. ISO 4401, 02/03/05/07/08 General Description.

Solenoid directional valves type DPHI, DPHE, DPHER two stage, ISO 4401 size 10, 16, 25 and 32

Functional Symbols and Application Notes

D03 FluiDyne Valves. ENGINEERING DATA

Direct Operated Proportional DC Valves

SECTION TITLE HEC2003/2004 SERIES SERVO VALVE SYSTEM ACCESSORIES KEY FEATURES

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

EManually Operated Directional Valves

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

RA / Accumulator unloading valve, pilot operated, Model DA 6 V.., series 4X. Ordering details DA 6 V 4X. Preferred models 1/8.

Directional Control Valve Series 4D01 (DENISON)

Proportional Valves. Proportional Directional and Throttle Valves Solenoid Operated

High Response Type Proportional Electro-Hydraulic Directional and Flow Control Valves

COMPACT CATALOG MONOBLOCK DIRECTIONAL CONTROL VALVES

VSD10M DIRECTIONAL CONTROL VALVES SOLENOID ACTUATED, PILOT OPERATED

Directional Control Valves

High Pressure, High Flow Rate Modular Valves

280 Series Stainless Steel Rotary Direction Control Valve For hydraulics in a harsh environment.

These valves may be used to manually shift the spool position and change the direction of oil flow *2 1.8

Pilot Operated Directional Valves

Monobloc and Sectional Directional Control Valves

D05 Directional Control Valves

Open center control block in mono block design MO-16, 22, 32

Monobloc and Sectional Directional Control Valves

Type : V20 Nominal Flow : 80 LPM Maximum Flow : 135 LPM (36 GPM) Max. Pressure : 350 Bar (5000 psi) Medium : Mineral Oil

Proportional Valves. Proportional Two-Stage Directional Valves

Transcription:

ENGINEERING SECIFICIONS High ressure, Subplate Mounted Directional Control Valves MODEL H03 5 gpm (19 L/min) nominal 10 000 psi (700 bar) H03 valves are rated for 5 gpm (19 L/min) nominal flow at pressures to 10 000 psi (700 bar). Flows to 15 gpm (57 L/min) are possible with some models (See ypical Valve erformance, pages 3-). hese high performance valves operate reliably at pressures double that of conventional subplate mounted valves. he reliable sliding-spool valves provide true four-way control in a simple compact package. SMOOH, RECISE SHIFING Spool travel is exceptionally smooth because of a four-land spool design. dditional outboard lands provide greater support than two-land designs. alancing grooves provide precise centering, reducing silt buildup. Close tolerances assure accurate land sequencing and low leakage. RELILE VLVE SELING apered o-ring counterbores reduce leakage, by assuring seal retention in rapid cycling operation. Hightorque mounting prevents weepage. H03 Valve With Optional lug-in-erminal Solenoids SOLENOID DVNGES Solenoid models are quiet and weather-tight for extra-long life. Wet armature design eliminates dynamic seals and increases the available shifting forces. Static o-rings prevent external leakage. Weather-ight Solenoids MNUL OVERRIDE Solenoid override pins are made from corrosion-resistant brass for trouble-free operation. Convenient hand-actuated override, available as an option, provides solenoid override without the use of tools. LUG-IN ERMINL SOLENOIDS Optional solenoid plugs simplify electrical connections during installation and servicing. hese integral three-terminal, bi-polar plugs fit DIN Connector Standard 36 (Hirschmann GDM 9). Hand-ctuated Override LEVER-OERED MODELS Lever operated valves offer superior handle position flexibility. Choose from eight different locations to put the handle where it is best for operator convenience.

Valve Specifications and pplication Data SECIFICIONS Special Mounting lthough similar to standard NF D03 (CEO 3) valves in size, H03 valves require a special mounting pattern. Refer to page 5. Rated ressure 10 000 psi (700 bar) Rated Flow 5 gpm (19 L/min) nominal; See ypical Valve erformance, page 3. ank ort ressure (Maximum) Manual Operated Models: 3000 psi (210 bar); Solenoid ctuated Models: Standard, 1000 psi (70 bar) dynamic, 3000 psi (210 bar) static; High ressure Option (H), 3000 psi (210 bar) dynamic, 00 psi (3 bar) static; Hydraulic and air actuated models: Standard, 10 SI (105 bar); Response ime (Full Stroke) Solenoid Energized:.C., 12 ms; D.C., ms Spring Returned:.C., 15 ms; D.C., ms Solenoids vailable with.c. or D.C. solenoids. For electrical options refer to ypical Model Code on page 8. For complete installation details on these options, refer to ulletin VES. Electrical Connections Standard Wiring ox with leads; Optional erminal Strip, Cable Grip or in Connector (N.F... standard 3.5-29-1980;.N.S.I. standard 93,55M-1981); Optional lug-in-erminal Solenoids fit DIN Connector Standard 36 (Hirschmann GDM 9) Explosion roof (EW Option) Solenoids with special enclosures are approved by UL and CS for use in hazardous locations. UL Classification: Class I, Group C, D; Class II, Group E, F, G CS and UL Recognized (C Option) Solenoid coils are printed with the symbol: (CS and UL Recognized) C vailable with 115/DF coils only. For other voltages, contact the Dynex sales department. ELECRICL D Solenoid Code ➀ Input Voltage (Volts) Frequency (Hz) Inrush Current (mps) Holding Current (mps) Holding ower (Watts) 115/DF 110.C. 1.65.7 0 (Dual Frequency) 115.C. 60 1.55.0 230/DF 2.C..86.22 1 (Dual Frequency) 230.C. 60.80.18 1 60/DF 0.C..1 23 600 (Dual Frequency) 60.C. 60.0.10 21 600 12 VDC 12 D.C. 2.33 2.33 28 5.1 2 VDC 2 D.C. 1.17 1.17 28.6 115/60 EW 115.C. 60 1.90. 23 33.5 ➀ Ordering Codes shown are for standard wire leads with wiring box. lug-in-erminal solenoids (Hirschmann GDM 9) are also available; see ypical Model Code on page 8. MNUL OERED MODELS Lever operated models offer handle position flexibility with four positions on either port end or port end of valve. In-the-field changes are easy, by removing the bracket assembly and rotating the handle to the desired position. o specify position, see the installation drawing on page 7 and refer to ypical Model Code on page 8. LICION D Flow ctuating attern Operating actuator opens flow path to port ( ). Operating actuator opens flow path to port ( ). Models with Code 6 operators, which are actuator centered, are the exception. Spring-centered or spring-offset models are spring positioned unless actuated continuously. Valves with detented operation can be actuated momentarily (minimum electrical signal duration, ms) to shift and hold the spool in that position. Mounting osition Unrestricted for all models. Standard Seals ll valves use fluorocarbon (Viton or Fluorel ) o-rings, providing greater fluid compatibility and improved temperature range performance. Fluid Recommendations to 10 SUS (7 to 323 cst) viscosity; - to 0 F (-29 to 93 C) temperature range. Filtration Five micron or better is recommended for this high pressure valve. Coil Resistance (Ohms ± 10%) Fine filtration is especially critical for sliding spool valves held in one position for long periods, subjected to high system pressures. Silting may cause spool sticking and improper shifting. o further prevent this occurrence, valves should be cycled periodically. Differential Cylinder Circuits High differential flows in cylinder circuits can cause any hydraulic valve to malfunction. Contact the Dynex sales department for a review of applications with differential flows ( versus, or versus ) above 6.6 gpm (25 L/min). ressure Surges Consistent with standard practice, the system should be protected from pressure surges. With a common tank line serving multiple valves, shifting of any spool valve can be affected by surges of oil. separate line to tank, or to another low pressure line, is recommended. his is particularly critical with detented models. 2

Selecting Spools and Internal Operators SOOL SELECION he table at right shows the most common spools. Refer to ypical Model Code on page 8 for a complete listing of spool types. Lever actuated models, with Code 1 or Code 2 internal operators, use ype 0 or ype 1 spools. ll other models with Code 1 or Code 2 internal operators use ype or ype 21 spools. ype 0 and ype 1 spools provide the same function, but are not interchangeable with ype or ype 21 spools. INERNL OERORS he table shows available internal operators with flow symbols. Note the following exceptions: Code 3 operators in models with lever actuators provide three position, detented operation. With Code and Code 6 operators, flow can be reversed with the R option. For example, with R in the model code, a Code operator with a ype 0 spool will direct flow to port ( ) in the actuated position. INERNL OERORS Operator Code 1 2 3 5 6 7 ctuator, Operation Single ctuator, wo osition Single ctuator, wo osition Spool ypes FLOW CCIY SOLENOID MODELS Non- ctuated 0, Offset 1, 21 03 Offset 0, Offset 1, 21 03 Offset Operator Function ctuated Double ctuator, ll Detented in or wo osition ypes ctuated ositions Single ctuator, wo osition 0, 1, 3 011 Spring Centered Spring Centered Double ctuator, ll Spring or hree osition ypes Centered Single ctuator, wo osition 0, 1,3 011 Spring Offset Spring Offset Centered Centered Single ctuator, Detented in or 0 or 1 wo osition ctuated ositions Function Symbol ypical Valve erformance SOLENOID MODELS he curves at right show typical flow capacity for each spool type. he letters in the Flow Curve Reference table identify the appropriate curve. For example, in the table under spool ype 0, curve L is called out for models with Code 5 internal operators and D.C. solenoids. Looking at the curves, L indicates a maximum capacity of 15 gpm (57 L/min) at pressures to 10 000 psi (700 bar). RESSURE Operator Code R 700 600 0 00 300 0 100 0 SI 10000 8000 6000 000 00 U.S. GM L/MIN 2 10 FLOW CURVE REFERENCE 6 8 10 12 1 16 C D E G F 30 FLOW H J K L 1 ll ypes K L 2 ll ypes K L 3 ll ypes L 5 Solenoid ype Spool ype 0 1 21 3 011 2 2R 32 32R 36 03.C. E L L L G C C D H D.C. & EW L L L L G G G L L L L.C. E L L L G C C D H D.C. & EW L L L L G G G L L L L 6 ll ypes L L L L F F F L L L J 0 60 3

LEVER OERED MODELS Most manual models are rated for 15 gpm (57 L/min) maximum. he exceptions are models with internal operators and spool types shown in the table below. FLOW LIMIIONS Operator Code Spool ype Maximum Flow gpm L/min 0 7.0 26 1 1 8.0 ➀ 30 ➀ 03 7.0 26 0 7.0 26 2 1 8.0 ➀ 30 ➀ 03 7.0 26 1 8.0 ➀ 30 ➀ 3 011 7.5 28 2 or 2R 7.5 28 5 1 8.0 ➀ 30 ➀ 7 1 8.0 ➀ 30 ➀ ➀ 8 gpm (30 L/min) at 10 000 psi (700 bar). Flow capacity increases with reduced pressure; i.e., 11 gpm (1 L/min) at 00 psi (10 bar). ILO OERED MODELS he maximum flow for pilot operated models is dependent on pilot pressure. Generally, the maximum flow for most pilot operated valves is 8 gpm (30 L/min). When using a ype 011 spool (tandem center), the maximum flow rating is 6 gpm (23 L/min). Minimum ilot ressure he table at right shows the minimum pressure required to shift the spool at a nominal flow of 5 gpm (19 L/min). hese values are based on zero tank pressure. For hydraulic piloted models, as back pressure increases above zero, the minimum pilot pressure must be increased equally. Maximum ilot ressure Hydraulic, 3000 psi (210 bar); ir, 0 psi (1 bar) Volume Maximum required to shift spool full stroke: Hydraulic, 0.01 in 3 (0,23 cm 3 ); ir, 0.2 in 3 (3,61 cm 3 ) MINIMUM ILO RESSURE Series Spool ype ilot ressure at 5 gpm (19 L/min) psi bar 0 or 215 1,8 1 or 21 215 1,8 3 215 1,8 6800 Series 215 1,8 Hydraulic 011 360 2,8 iloted 2 or 2R 360 2,8 32 or 32R 260 17,9 36 260 17,9 03 215 1,8 0 or 35 2, 1 or 21 28 1,9 3 35 2, 6900 Series 35 2, ir 011 3, iloted 2 or 2R 3, 32 or 32R 0 2,8 36 35 2, 03 35 2, Determining Valve Efficiency RESSURE DRO he curves at right indicate pressure drop for all H03 valves, except manual operated (see page 5 for those curves). hese curves show resistance to flow for specific flow paths and various spool types. he Flow Curve Reference table identifies the proper curve. Maximum flow capacity depends on valve actuator, internal operator, spool type and other application factors. Refer to ypical Valve erformance on page 3. N EXMLE In the table under spool ype 1, curve D is called out to determine the pressure drop for. Looking at the curves, D indicates a drop of about 65 psi at 5 gpm (,5 bar at 19 L/min). o determine total loop drop, the individual pressure drops for and (or and ) must be added. RESSURE DRO ( ) LL MODELS EXCE LEVER CUED RESSURE R 32 28 2 16 12 8 0 SI 00 3 300 2 0 1 100 U.S. GM L/MIN 2 6 8 10 12 1 16 10 30 FLOW 0 C D E F ➀ hese curves indicate efficiency for various spool types. For maximum flow capacity refer to curves on page 3. FLOW CURVE REFERENCE Flow Spool ype ath 0 1 21 3 011 2 2R 32 32R 36 03 D E D C C C D E D C C C E E G G H E E E E E E E E E G G H E E E E E E E D D 60 G H

LEVER CUED MODELS he curves at right indicate pressure drop for lever actuated H03 valves. hese curves show resistance to flow for specific flow paths and various spool types. he Flow Curve Reference table identifies the proper curve. Maximum flow capacity depends on valve actuator, internal operator, spool type and other application factors. Refer to the Flow Limitations table on page. N EXMLE In the table under spool ype 1, curve C is called out to determine the pressure drop for. Looking at the curves, C indicates a drop of about 60 psi at 5 gpm (,1 bar at 19 L/min). o determine total loop drop, the individual pressure drops for and (or and ) must be added. RESSURE DRO ( ) LEVER CUED MODELS RESSURE C D R SI E 32 F 28 2 16 00 3 300 2 G 12 0 8 1 100 0 U.S. GM 2 6 8 10 12 1 16 L/MIN 10 30 0 60 FLOW FLOW CURVE REFERENCE Flow Spool ype ath 0 1 3 011 2 2R 32 32R 36 03 C C C C F G G F D D D F F F F G G F D D D F F F Installation and Dimensions SECIL VLVE MOUNING he mounting surface drawing shows the minimum flush or raised surface required for this special pattern. Mounting face must be flat within 0.000 inch/.0 inches (0,010 mm/102 mm) with a surface finish of 32 microinch (0,80 µm). ort o-rings are included with all valves. Mounting bolts must be ordered separately;.2- UNC hreaded x 0.75 inch (19 mm), Grade 8 or better; four required. Recommended mounting torque is 12 lb ft (16 N m) maximum..16 (,1);.16 (,1) DEE MINIMUM LOCING IN HOLE 32 (,80).000/.0 (,010/102) (,5).23 (5,9) 3 ORS.2 (6,35) 1 OR 2.00 (,8) (0,9).75 (12,07).8 (21,) 1.213 (30,81).19 (,8) 1.2 1.093 (31,75).157 (27,77) (3,99).625 (15,88).25 (6,) Minimum Mounting Surface, Special H03 attern.2 U.N.C. 2 HREDED.3 (10,9) DEE MINIMUM, MG. HOLES 5

SULE ND OL KIS Subplates are available for mounting H03 pattern valves, with a choice of S..E. or ritish Standard ipe (.S..) ports, or ports which fit utoclave or utech fittings. Mounting bolts are supplied with kit. When ordering together, valves are not mounted on subplates. KI R NUMERS art Number Description SO29-SE-6 Side orts, S..E. No. 6 SO29-S-6 Side orts,.s.. No. 6 SO30.8125-16 U.N.-2 hreaded ➀ 11-K ().2- UNC (olt Kit) hreaded x 0.75 Inches (19 mm) 108113 For mounting EW models on (Spacer late) side-ported subplate/manifolds. For use with above spacer: 11-KE ().2- UNC (olt Kit) hreaded x 1. Inches (38 mm) ➀ High pressure port fits utoclave Medium ressure, utech M/ or equivalent fitting. SOLENOID MODEL DIMENSIONS Dimensions are shown, at right, for both.c. and D.C. solenoids; D.C. configuration shown printed in gray. Overall length of single solenoid configuration (not shown) is 6.78 inches (172,2 mm),.c.; and 7.39 inches (187,7 mm), D.C. Single Solenoid:.C., 3. lb (1,5 kg); D.C., 3.9 lb (1,8 kg) Double Solenoid:.C.,.0 lb (1,8 kg); D.C., 5.3 lb (2, kg).33 (8,71) WI H. (12,7) COUNERORE x (9,) DEE, 2 SULE MG. HOLES.2 U.N.C. 2 HREDED.3 (10,9) DEE MINIMUM, MG. HOLES (0,9) MNUL CUOR IN 1.213 (30,81).75 (12,06).16 (,1).16 (,1) DEE MINIMUM LOCING IN HOLE 2.7 (69,6).38 (9,7) GRI 3.73 (9,7).88 (22,) (9,) (,) CLERNCE O REMOVE COIL 1.68 (2,7) (.C.) 2.30 (58,) (D.C.).625 (15,88) Subplate SO29-SE-6 or SO29-S-6 or SO30 SOL. FOR YE 0, 1, 3,, 03, 32, 32R, 36 ( OR 21 FOR CODE 1 OR 2 OEROR) SOOLS; SOL. FOR YE 011, 2, 2R SOOLS 1.88 (7,8).9 (23,9) 2.75 (69,8) [SO30 ONLY] 2. (63,5) 1.875 (7,62).68 (11,89).68 (11,89) 1.2 (31,75).31 (7,9) (,) Y. 2 LCES 2.875 (73,02) 3..8 (88,9) (21,).31 (7,9).2- U.N.C. HREDED x.75 (19,0) LONG MG. OLS, REQUIRED; ORQUE: 12 L F (16,3 N M) MXIMUM (3,3) 1.25 (31,8) Y. 2 LCES.62 (15,7) Y. LCES 5.00 (127,0).92 (23,) 8.5 (.C. SOLENOID) (216,9) 9.77 (D.C. SOLENOID) (28,2) 60 Series, Double Solenoid Models 1. (38,1), ND ORS (3) NO. 6 S..E. (MODEL SO29-SE-6), NO. 6.S.. (MODEL SO29-S-6), OR.8125-16 U.N.C. 2 HREDED, FIS UOCLVE MEDIUM RESSURE, UECH M/, OR EQUIVLEN(MODEL SO30). 0 1 N..., SNDRD ELECRIC ENRY, 1 ECH SIDE.125 (3,18) LOCING IN 32 (,80).000/.0 (,010/102) OR NO. 6 S..E. (MODELS SO29-SE-6 ND SO30), NO. 6.S.. (MODEL SO29-S-6) 2.51 (63,8) (.C.) 3.12 (79,2) (D.C.) SOL. FOR YE 0, 1, 3,, 03, 32, 32R, 36 ( OR 21 FOR CODE 1 OR 2 OEROR) SOOLS; SOL. FOR YE 011, 2, 2R SOOLS EXLOSION ROOF SOLENOIDS Solenoids with special enclosures are approved by UL and CS for use in hazardous locations (available.c. only). Overall length of single solenoid model (not shown) is 8.23 inches (9,0 mm). Note that spacer plate (No. 108113) is required when valves are mounted on manifolds, side outlet subplates or when used as a pilot valve. Valves can be mounted without removing nameplate. Openings in plate provide access to mounting holes in valve body. Single Solenoid: 8.3 lb (3,8 kg); Double Solenoid: 1.0 lb (6, kg) 5.88 (22,) (,) CLERNCE O REMOVE COIL 1/2 INCH N... SND. ELECRIC ENRY, 360 ROLE WIH OOM OULE SULE 2.88 (73.2) (9,) 1 (28,7) GRI SOLENOID OSIION LIMI WIH SIDE OULE SULE 3.25 (82,6) MNUL CUOR IN 3.72 (170,7) 1.69 (2,9) SOL. FOR YE 0, 1, 3,, 03, 32, 32R, 36 ( OR 21 FOR CODE 1 OR 2 OEROR) SOOLS SOL. FOR YE 011, 2, 2R SOOLS SCER NO. 108113 1.63 (1,) (3,3).2- U.N.C. HREDED x 1. (38,1) LONG MG. OLS, REQUIRED, ORQUE: 12 L F (16,3 N M) MXIMUM GROUNDWIRE (2) Y. #18 WG (GREEN INSULION) ROX 18 (57) LONG NOE: KEE IR G EWEEN SOLENOID ND VLVE ODY CLEN.125 (3,18) LOCING IN 12. (317,5) 60 Series, Double EW Solenoid Models LEDWIRES () Y. #18 WG, ROX 18 (57) LONG SOL. FOR YE 0, 1, 3,, 03, 32, 32R, 36 ( OR 21 FOR CODE 1 OR 2 OEROR) SOOLS SOL. FOR YE 011, 2, 2R SOOLS.75 (19,0).92 (23,).9 (11,0) 6

MNUL OERED MODELS Manual models are lever actuated, with handle located in a choice of four positions on either port or port end of valve. HNDLE OSIION FOR O FOR YE 0, 1, 3,, 03, 32, 32R, 36 SOOL; O FOR YE 011, 2, 2R SOOL 1.5 1.5 HNDLE OSIION FOR O FOR YE 0, 1, 3,, 03, 32, 32R, 36 SOOL; O FOR YE 011, 2, 2R SOOL Valves can be mounted without removing nameplate. Openings in plate provide access to mounting holes in valve body. o specify handle position, see the drawing below and refer to ypical Model Code on page 8. 3.2 lb (1,5 kg) HNDLE OSIION FOR O FOR YE 0, 1, 3,, 03, 32, 32R, 36 SOOL O FOR YE 011, 2, 2R SOOL 2.09 (53,1).38 (9,7) GRI 1. (36,6).9 (23,9) 5.5 (138,) 9 or 9 12 or 12 3 or 3.125 (3,18) LOCING IN (3,3).03 (102,) 5.21 (132,3) 5.83 (18,1) WIH HNDLE OFFSE (9,).88 (22,) (,).2- U.N.C.HREDED x.75 (19,0) LONG MG. OLS, REQUIRED, ORQUE: 12 L F (16,3 N M) MXIMUM 6 or 6 Handle osition Viewed from ort or ort End of Valve 6100 Series, Manual Lever Operated Models HYDRULIC ILOED MODELS Single and double actuator models are available. Overall length of single actuator configuration (not shown) is 5.25 inches (133, mm). Valves can be mounted without removing nameplate. Openings in plate provide access to mounting holes in valve body. Refer to page for required shifting pressure and volume. Single ctuator: 2.5 lb (1,1 kg); Double ctuator: 2.8 lb (1,3 kg) ILO FOR YE 0, 1, 3,, 03, 32, 32R, 36, ( OR 21 FOR CODE 1 OR 2 OEROR) SOOLS; ILO FOR YE 011, 2, 2R SOOLS.87 (22,1) HEX.2- U.N.C. HREDED X.75 (19,0) LONG MG. OLS, REQUIRED, ORQUE: 12 L F (16,3 N M) MXIMUM 6.7 (16,3) 1.7 (37,3) (3,3) 125 (3,18) LOCING IN.92 (23,) ILO OR (2) NO. S..E. O-RING SR. HR'D. 2.09 (53,1).9 (23,9) 6800 Series, Double Hydraulic iloted Models ILO FOR YE 0, 1, 3,, 03, 32, 32R, 36, ( OR 21 FOR CODE 1 OR 2 OEROR) SOOLS; ILO FOR YE 011, 2, 2R SOOLS (9,) (,5).38 (9,7) GRI.87 (22,1) IR ILOED MODELS Single and double actuator models are available. Overall length of single actuator configuration (not shown) is 5.56 inches (11,2 mm). Valves can be mounted without removing nameplate. Openings in plate provide access to mounting holes in valve body. Refer to page for required shifting pressure and volume. Single ctuator: 2.3 lb (1,0 kg); Double ctuator: 2.5 lb (1,1 kg) ILO FOR YE 0, 1, 3,, 03, 32, 32R, 36, ( OR 21 FOR CODE 1 OR 2 OEROR) SOOLS ILO FOR YE 011, 2, 2R SOOLS 1.25 (31,8) HEX (3,3).2- U.N.C. HREDED x.75 (19,0) LONG MG. OLS, REQUIRED, ORQUE: 12 L F (16,3 N M) MXIMUM 7.09 (180,1).92 (23,) 1.78 (5,2) 125 (3,18) LOCING IN 6900 Series, Double ir iloted Models 2.09 (53,1).9 (23,9) ILO FOR YE 0, 1, 3,, 03, 32, 32R, 36, ( OR 21 FOR CODE 1 OR 2 OEROR) SOOLS ILO FOR YE 011, 2, 2R SOOLS ILO OR (2) 1/8 INCH N... (9,) (,5).38 (9,7) GRI.87 (22,1) 7

6 5 0 H03 115/DF R * SL Valve ype 6 Subplate Mounted Directional Control H03 Valve Size High ressure, 10 000 psi (700 bar), Special Mounting attern Reverse Flow Operator (Code and 6 Only) R Code : wo osition; Spring Centered, ctuator Offset ( ) Code 6: wo osition; Spring Offset ( ), ctuator Centered Design Number ctuator 1 Manual Lever 5 Solenoid Operated 8 Hydraulic iloted 9 ir iloted Internal Operator 1 wo osition; Spring Offset ( ), ctuator Offset ( ) ➀ 2 wo osition; Spring Offset ( ), ctuator Offset ( ) ➀ 3 wo osition; ctuator Offset, Detented for Non-Manual ctuators hree osition; Detented for Manual Lever wo osition; Spring Centered, ctuator Offset ( ) ➁ 5 hree osition; Spring Centered, ctuator Offset 6 wo osition; Spring Offset, ctuator Centered ➁ 7 Manual Lever Only: wo osition, Detented ➀ Only available with ype and ype 21 spools (except manual lever models). ➁ Not available with Manual Lever Operated valves. Spools 0, ➀ 2 ➁ 1, 21 ➀ 2R ➁ 3 ➁ 32 ➁ ➁ 32R ➁ 011 ➁➃ 36 ➁ 03 ➂ ➀ Code 1 or Code 2 operators (non-lever actuated models) use ype or ype 21 spools. hese spools provide the same function, but are not interchangeable with ype 0 or 1 spools. ➁ Not available with Code 1, Code 2, or Code 3 Internal Operators (except manual lever models). ➂ Not available with Code 1 or Code 2 Internal Operators (except manual lever models). ➃ Open crossover. C M CG SL H SNDRD SOLENOIDS: 2/DF Dual Frequency, 2/60, 2/ 115/DF Dual Frequency, 115/60, 110/ 230/DF Dual Frequency, 230/60, 2/ 60/DF Dual Frequency, 60/60, 0/ 12VDC Direct Current, 12 Volts 2VDC Direct Current, 2 Volts 12VDC EW Explosion roof Solenoids 2VDC EW Explosion roof Solenoids 115/60 EW Explosion roof Solenoids 110/ EW Explosion roof Solenoids 2/ EW Explosion roof Solenoids Lever osition (Manual Models Only) 12 12 o clock position, on port end of valve 9 9 o clock position, on port end of valve 6 6 o clock position, on port end of valve 3 3 o clock position, on port end of valve 12 12 o clock position, on port end of valve 9 9 o clock position, on port end of valve 6 6 o clock position, on port end of valve 3 3 o clock position, on port end of valve Options (Solenoid Models Only) CS and UL Recognized Coils (Etched with Symbol) ➀ Hand ctuated Manual Override ➁ erminal Strip ➁➂ Cable Grip, for 3/8 to 7/16 inch (9,5 to 11,1 mm) O.D. machine tool cable ➁➂ Solenoid Lights (vailable 115/DF.C. Only) ➁➂ High ressure ank ort 2300 SI (160 bar) maximum.c. models 3000 SI (210 bar) maximum D.C. models H3 3-pin Connector, for single solenoid models, on port end of valve ➁➂➃ H3 3-pin Connector, for single solenoid models, on port end of valve ➁➂➃ H5 5-pin Connector, for single or double solenoid models, on port end of valve ➁➂➃ H5 5-pin Connector, for single or double solenoid models, on port end of valve ➁➂➃ ➀ vailable with 115/DF solenoids only. For other voltages, consult the Dynex sales department. ➁ Option not available with EW solenoid models. ➂ Option not available with lug-in-erminal solenoid models. ➃ NF standard 9-1980; NSI standard 93.55M-1981. Electrical Solenoid Options For Other Voltages, Consult the Dynex Sales Department ➀ Fits DIN Connector Standard 36 (Hirschmann GDM 9) LUG-IN ERMINL SOLENOIDS: ➀ 115/HC Dual Frequency, 115/60, 110/ 230/HC Dual Frequency, 230/60, 2/ 12/HDC Direct Current, 12 Volts 2/HDC Direct Current, 2 Volts US Headquarters Dynex/Rivett Inc. 770 Capitol Drive ewaukee, WI 53072 el: (1) 691-2222 FX: 1-691-0312 E-mail: sales@dynexhydraulics.com Web Site: www.dynexhydraulics.com ower Units & Systems Dynex/Rivett Inc. 5 Nickerson Road shland, M 01721 el: (8) 881-5110 FX: 8-881-689 European Sales Dynex/Rivett Inc. Unit C5 Steel Close, Little End Road, Eaton Socon, Huntingdon, Cambs. E19 3JH United Kingdom el: + (0) 180 213980 FX: + (0) 180 05662 Copyright Dynex/Rivett Inc. rinted in U.S.. ulletin VES.H03-E099