Solenoid drive. Operating instructions

Similar documents
Holtumsweg 13, D Weeze, Tel /9134-0, Fax /1444

Technical Data. Dimensions

Ex m Solenoid Operator Type 0519

ILED Dorado. User Manual

Solenoid Operator 0516 / 1216

Solenoid coil for control in potentially explosive areas Type BZ

Solenoid Operator 0513 / 1213

Installation and Operational Instructions for ROBA-stop Holding Brake Type _._

Mechanical Operating Instructions

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Softstarter SAS SAS 11PUST, 22PUST Assembly- and Commissioning Instructions

2/2 Solenoid Cartridge Valve, Size 6

Installation and Operating Instructions

Installation and Operating Instructions for ROBA-stop -Positioning Brake Type 80_.41_._ Sizes 3 11

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

INSTRUCTION MANUAL (ATEX / IECEx)

Installation and Operational Instructions for ROBATIC -clutch Types _.0 and _.0 Sizes 3 7

Installation and Operational Instructions for ROBATIC -clutch Type and Type Sizes 3 9

PTB 14 ATEX 2023 X, EPS 16 ATEX 1046 X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

PTB 14 ATEX 2023 X, IECEx PTB X. Operating Instructions. Solenoid coil Type AC10 Magnetspule Typ AC10 Bobine magnétique Type AC10

GuaRdboX - Gd series IOM (Installation, Operation & Maintenance Manual) 0100-ENG rev.4

Installation and Operating Instructions

These operating instructions apply for: NCX 380 NCZ 300 NCX 480 NCZ 370 NCX 580 L NCZ 480 NCX 660 K NCZ 560 NCZ 660 NCZ 800

FLUDEX - thermal switching equipment. Operating instructions BA en 04/2012. FLENDER couplings

3/2 and 4/2 directional seat valves with solenoid actuation

Operating Manual (Edition 04/2004) sinamics. Braking Module / Braking Resistor SINAMICS G130

EPS 16 ATEX 1072 X, IECEx EPS X. Operating Instructions. Solenoid coil Type AC19 Magnetspule Typ AC19 Bobine magnétique Type AC19

Segurança. Segurança. PSB Heating System Cold applied connection technology. Compulsório. Compulsório. Operation Manual and Installation Instructions

OPERATING INSTRUCTIONS

INSTRUCTION MANUAL (ATEX / IECEx)

10 Load and Motor Switchgear

Technical Data Sheet

p max (see table of performances) Q max (see table of performances) bar Maximum flow l/min see par

ELECTROMAGNETIC DISC BRAKES H2SP SERIES WITH CONSTANT BRAKING TORQUE

Operating Instructions

Installation and Operational Instructions for ROBA-stop -tacho brake Type 83_.41_._ and ROBA-stop -tacho peak load brake Type _.

ILED Aquarius Illuminated Windsock. User Manual

Operating Instructions for Roll-Up Door Operators / MDF

EX T... AT. Sensors with switching function. Identification II 2 G Ex db eb mb IIC PTZ 16 ATEX 0024

HYDRONIC LIFT SOLUTION FOR A3 AMENDMENT

Body: Seat disc: Anod. aluminium body NBR. Connection / Orifice Flow factors Temperature values ( C)

DEVICE STATE/BYPASSED FAILURE OVERLOAD

Robots. KUKA Roboter GmbH KR 500 FORTEC. With F and C Variants Specification. Issued: Version: Spez KR 500 FORTEC V3

DC Single-Acting High Performance Solenoids

10 Load and Motor Switchgear

Directional Control Valve Series D1VW

3/2 Way Valve G1/8. Data Sheet No E. Characteristics Symbol Unit Description General Features Spool valve.

Miniature Circuit-Breakers (MCBs)

Mounting and Operating Instructions EB 8111/8112 EN. Valve Series V2001 Globe Valve Type 3321

Control and Terminal Box Type A21-**-*****

Solenoid coils VACF Type codes

SIRIUS 3RU2 Thermal Overload Relays

Braking Devices BR 230/ Assembly- and Commissioning Instructions

Solenoid System KNURLED NUT TOP CORE GUIDE TUBE PLUNGER

Explosion-proof Solenoids ATEX. II 2 G / II 2 D EEx dm IIC T4, T5, T6. Catalogue 8735/GB. Maximum photo

INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement.

Wilo-Control SC-Fire Jockey

Installation manual wall-mounted distributor

HIGH VOLTAGE TEF 1060 HV ENCLOSURE WITH A-BLOCK SOLUTIONS USER MANUAL

Chapter 2: Directional Control Valves

Junction box for EKL light

Solenoid Valves Type 3963

Operating Instructions

Installation and Operational Instructions for ROBA -D Couplings Type 91_. _

Installation manual portable distributors

Operating Instructions

Type AK-Ex FOR LOW-LEAKAGE SHUT-OFF OF VOLUME FLOWS IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX)

Appendix: Operation of Explosion- Protected Motors acc. to ATEX 100a

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

Operating instructions Solenoid interlock EX-AZM About this document. Content

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

Installation and Operating Instructions for ROBA-stop -silenzio Type 896._3_. Sizes

3RG4 BERO Inductive Proximity Switches

Solenoid System. The coil is also in conformity with 94/9/EC ATEX for electrical apparatus of group II, category 3 (Ex na II 3 GD T4 or T5).

Instruction Manual. Ex-Time 40 / 50

Unified requirements for systems with voltages above 1 kv up to 15 kv

Mounting and Operating Instructions EB 5868/5869 EN

Segurança. Segurança. MSB/HSB Heating System. Compulsório. Compulsório. Operation Manual/Installation Instructions. Cold applied connection technology

EPS 16 ATEX 1111X, IECEx EPS X. Operating Instructions. Solenoid coil Type ACP016 Magnetspule Typ ACP016 Bobine magnétique Type ACP016

Operation & Maintenance Manual

Mounting and Operating Instructions EB 8227 EN. Pneumatic Control Valve Type 3331/BR 31a Special version Type 3331/3278. Type 3331 Butterfly Valve

DC-PMM/24V Power Management Modul für Positionier-Motor POSMO A Power Management Module for Positioning Motor POSMO A

IQL Helios Area-/Streetlight. User Manual

15 mm Pilot Valve. More technical specifications are reported in the following pages. 1

Operating Instructions for Float Flow Meter / Monitor. Model: SWK

Control Panels, Distribution Panels and Components

ATEX instruction APP S 674 pumps APP S , APP S and APP S

UV- TECHNOLOGY. Technical Documentation ELC N6 / ELC N8 / ELC N10

Table of contents NLE 2 x 36 W T8, 230 V, 4 Ah, 1.5 h 4

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

Volute Casing Centrifugal Pumps in In-line Design with Magnetic Drive. Series CNI-M

ATS22D88Q soft starter-ats22-control 220V-power 230V (22kW)/ V(45kW)

EPS 16 ATEX 1121 X, IECEx EPS X Solenoid coil Type 06xx Magnetspule Typ 06xx Bobine magnétique Type 06xx. Operating Instructions

Operating and Installation Manual Shut-off damper Type AK-Ex with control components T0* and P50

Electromagnetic Flow Monitor magphant

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

KR 30, 60-4 KS; KR 60 L16-2 KS

Operating Instructions. Angle Seat Control Valve. Type 7020

Installation Instructions

ATEX/IECEx Coil Manual Type 200 and 300 Series Coils for EH70 Series Solenoid Valves Issue , Released December 13, 2017

Transcription:

Operating instructions (translation) Explosion protection The explosion protection is an option and is indicated by an Ex type plate on the solenoid actuator. The solenoid actuators and integrated solenoid valve controllers conform to explosion protection type "na" category II3G and can be used in zones in which explosive gas, vapour, mist or air mixtures may occur, i.e. in explosion zone 2. The electrical and thermal parameters of the separate variants can be obtained from the respective type plates. The explosion protection applies to operation of the device. For installation, maintenance or repairs, it is imperative that the relevant explosion protection regulations, especially EN 6007914 (VDE 0165 T1), are observed. The electrical installation work must be carried out by, or under the supervision of, a skilled electrician, with additional observance of the relevant national regulations (VDE 0100 in Germany). Prior to installation, the constraints of the device marking must be compared against the envisaged operating conditions to ensure operation is as intended. Basics Valve solenoid actuator combinations are supplied fully assembled and tested as standard. When replacing or changing solenoid actuators, care should be taken that the combination with a UNI valve is approved and the magnet is properly secured to the valve (permissible tightening torque, for example). The devicespecific serial number for unequivocal identification and the year of build can be obtained from the type plate. Solenoid actuators are electrotechnical components that are inoperative without the associated valve and also may not be operated for themselves alone! For outdoor installations always use solenoid actuators with a IP65 rating and a rain cover. Any solenoid actuators showing signs of damage are not to be installed and must be replaced. If the solenoid actuators are subject to external loads of an exceptional kind, additional protective measures are to be taken by the operator, if required. Any undefined or unsuitable changes to the device may negatively influence the explosion protection and in the worst case even render it totally ineffective. UNI devices shall accept no liability for any loss or damage (to the device/over and above this) which have been brought about by change(s) to the device. The same applies for claims under the warranty. Description of the device The solenoid actuator (pot magnet) is used as an actuating unit for valves. Constructionally the actuator consists of a magnet housing (tube, base, magnetic disk and lid), a coil and electronics. Depending on the version, the solenoid actuator may be operated with DC or AC voltage. The version that runs off AC voltage has a builtin rectifier. Therefore when energised, direct current flows through the coils of all types. The solenoid actuators of type MG have a conventional coil with a winding and resulting average sustained pickup forces with average current consumption in continuous operation. The solenoid actuators of type MG A.. and MG A..C on the other hand have two windings on their coil body. One pickup and one holding winding. The TS / RKS builtin valve controller (rudimentary in " A " actuators) switches over after a defined time from the higher pickup power to the lesser holding winding power. In this way, very high pickup forces can be achieved shortterm with simultaneous low current consumption in sustained (holding) operation. Seite 1/ 14 TM 4021 220.100.818

Special condition for safe use 1. Since temperatures higher than 70 C occur at the cable entry and higher than 80 C at the core junction, this equipment must be additionally marked with the higher temperature (label at the cable entry). Only a heatresistant cable may be connected. 2. The solenoid actuators need to be protected against the dangerous consequences of short circuits, earth faults and overloads. A lineside fuse appropriate to the rated current (max. 3xIB acc. to IEC 6012721) is to chosen. A lineside motor circuit breaker with shortcircuit and thermal instantaneous tripping is to be adjusted for the rated current. If the magnet has very low rated currents, fusing with the lowest current value in keeping with the stated IEC standard is sufficient. Protective devices must be of the kind that prevents automatic reconnection under fault conditions. The fusing rated voltage must match or exceed the specified nominal voltage of the solenoid actuator. The breaking capacity of the fuse link must match or exceed the maximum shortcircuit current expected at the place of installation (usually 1500 A). 3. When a silicon (or silicon containing) connection lead is used or if the connecting lead is not scratch proof respectively, this has to be protected from mechanical damage (e.g. inetrrupted tube system with edge protection). 4. A maximum permissible ripple of 20% is valid for all magnets of dcdesign. Electrical connection The diameter range / clamping range of the cable gland must be noted and adhered to. The connection thread of the cable gland amounts up to 30 Watt M16x1,5, from 40 Watt M20 x 1,5.Where a flexible connecting line is used, insulated wireend sleeves with plastic collars conforming to DIN 46228 part 4 are to be used. The voltage supply at the solenoid actuator must lie within the range 15% to +10%. The appropriate circuit diagram can be obtained from the connection diagrams at the end of these operating instructions. To guarantee an IP65 degree of protection, the magnetic housing lid must be refitted carefully. Versions supplied with a connecting cable ex works are ready for use, i.e. the connection compartment does not need to be opened again. The capacitors in the solenoid valve control TS800C must be discharged by an expert. CEIdentification The Council of the European Community passed common directives for the free movement of goods within the European Community, which determine the minimum requirements for safety and health protection. The CEidentification confirms, that the products correspond to the EC directives, i.e. are in agreement with the relevant, especially harmonized standards. Note concerning directive 2014/34/EU (explosion protection directive ATEX 95): The solenoid drives (MG..Xn, MG..A..Xn, MG..A..C..Xn) fulfil the relevant requirements of directive 2014/34/EU; therefore they have the CEidentification as per annex X of the directive. The declaration of conformity is included. Note concerning directive 2014/30/EU (EMVDirective): The solenoid drives fulfil the requirements of the specification to be applied of the product families concerning the industrial sector as well as the sectors of private housing, business and trading, as well as of small businesses. On using of AC and DCvariants the user must provide a suitable mains filter (e.g. Xcapacitor 47 nf) at the mains entrance to attenuate the physically caused linerelated turnoff current of the solenoid. In the sense of the EMVdirectives solenoid drives with driving elements for valves are not regarded as independently operable appliances and are only processed further by expert companies, or respectively installed into a machine. They must not be started up until it was determined that the machine, or respectively, the complete line, corresponds to the regulations of the EMVdirectives. Seite 2/ 14 TM 4021 220.100.818

Note concerning directive 2014/35/EU (LowVoltage Directive): The solenoid drives (MG.., MG..A.., MG..A..C..) were developed, designed and produced in accordance with the standard Electromagnetic Appliances DIN EDV 0580. Thus they will also fulfil the requirements of the low voltage guidelines, which apply to rated voltages from 50 to 1000V AC and from 75 to 1500V DC. Operation 100% ED are permitted even in case of the most unfavourable ambient conditions permissible. Danger! During operation the solenoid drive may get hot. Don t touch, danger of injuries! During operation it must be guaranteed, that neither the maximum permitted ambient temperature or of the fluid nor the load limit (excess voltage) will be exceeded. If necessary the solenoid drive is to be protected against overcharging. All solenoid drives are wired with a varistor. To avoid induced voltage, which may cause damage of the line, the user must provide protective measures in case of necessity which go beyond the installed varistor. Dismounting of the solenoid drive Stop the solenoid drive and cut off voltage supply. Danger! During operation the solenoid drive may get hot. Don t touch, danger of injuries! MG 0801, 38 Unscrew and remove hexagonal nut (901). Completely remove solenoid drive ( 800) from the upper part of housing (106). Seite 3/ 14 TM 4021 220.100.818

MG 004 008 MG 010 020 Unscrew hexagonal head screw (900) and remove it including insulating bush (401*). Remove cover of solenoid housing (105*) from solenoid housing (1). Loosen and remove connecting bolt (501). volume control butterfly valve Loosen protective cap (505) and remove including oring (4*). Remove cover of solenoid housing (105*) from solenoid housing (1). Unscrew and remove hexagonal nut (901). Pos. Item Description 1 Solenoid housing 106 Upper part of housing 500 Magnet plate 501 Connecting bolt 701 Cable gland 702 Solenoid 714 Mains outlet 800 900 Hexagonal head screw 901 Hexagonal nut 1004 Casting compound Seite 4/ 14 TM 4021 220.100.818

Subsequently the solenoid housing (1) will be completely dismounted from the upper part (106) of the solenoid valve together with magnet plate (500) and coil (702). Remove magnet plate (500) and coil (702) from the solenoid housing (1). Notice! Before assembly or if the sealing elements are damaged, with solenoid actuator MG004 MG020 (solenoid housing cover (105*), insulating housing (401*) and flat gasket (402*)), or with solenoid actuator volume control butterfly valve (solenoid housing cover (105**), Oring (4**) and flat gasket (402**)), replace if necessary. Assembly will be done in reverse order Screw torques of the connecting bolt (501) and the hexagonal head screw (900) Screw torque Item 501 + 900 Thread size 4,6 Nm M6 11 Nm M8 22 Nm M10 62 Nm M14 MG... / MG...Xn Typ MG... P W 24 110 125 Nominal current A* 220 230 240 110 VAC 38 18 0,08 0801 16 1,5 004 10 0,4 0,09 0,05 0,04 0,04 0,09 0,04 0053 15 0,6 0,1 0,07 0,07 0,06 0,1 0,07 0082 30 1,3 0,3 0,1 0,1 0,1 0,3 0,1 010 40 1,7 0,4 0,2 0,2 0,2 0,4 0,2 012 50 2,1 0,5 0,2 0,2 0,2 0,5 0,22 014 70 2,9 0,6 0,3 0,3 0,3 0,6 0,3 016 90 3,8 0,8 0,7 0,4 0,4 0,4 0,8 0,4 018 125 5,2 1,1 1,0 0,6 0,5 0,5 1,1 0,5 019 160 6,7 1,5 1,3 0,7 0,7 0,7 1,5 0,7 230 VAC 020 175 12,5 1,6 0,8 0,8 0,7 1,6 1,3 *Amb.temp. 20 C at 100% duty cycle stationary warmed up (Amb.temp. 20 C at 0% duty cycle switch on moment / values x factor 1,25) Seite 5/ 14 TM 4021 220.100.818

MG...A / MG...A...Xn with integrated control TS900, TS1500 Typ MG..A.. P W Nominal current A* TS 900 TS 1500 24 110 220 230 240 110 VAC 230 VAC 016A 720/70 30/2,9 6,5/0,6 3,3/0,3 3,1/0,3 3,0/0,3 6,5/0,6 3,1/0,3 018A1 900/70 38/2,9 8,2/0,6 4,1/0,3 3,9/0,3 3,8/0,3 8,2/0,6 3,9/0,3 018A2 1200/70 11/0,6 5,5/0,3 5,2/0,3 5,0/0,3 11/0,6 5,2/0,3 019A1 1200/120 11/1,1 5,5/0,6 5,2/0,5 5,0/0,5 11/1,1 5,2/0,5 019A2 1500/90 14/0,8 6,8/0,4 6,5/0,4 6,3/0,4 14/0,8 6,5/0,4 019A5.3 400/20 17/0,9 3,6/0,2 1,8/0,09 1,7/0,09 1,7/0,08 3,6/0,2 1,7/0,09 019A5.4 400/50 17/2,1 3,6/0,5 1,8/0,23 1,7/0,2 1,7/0,2 3,6/0,5 1,7/0,22 *Amb.temp. 20 C at 100% duty cycle stationary warmed up (Amb.temp. 20 C at 0% duty cycle switch on moment / values x factor 1,25) MG...A5 / MG...A5...Xn With integrated control TS200 Typ MG... P W Nominal current A * 24 230 VAC 010A5 200/20 8,3/0,8 1,2/0,9 012A5 200/20 8,3/0,8 1,2/0,9 014A5 200/20 8,3/0,8 1,2/0,9 016A5 200/20 8,3/0,8 1,2/0,9 018A5 200/20 8,3/0,8 1,2/0,9 019A5 200/20 8,3/0,8 1,2/0,9 * Amb.temp. 20 C at 0% duty cycle switch on moment Switching Frequenzy: switchings / hour MG 1000 004 020 20 016A 020A 600 010A5 019A5 20 016A5C6, 019A5C6 ; 016A5.2C6, 019A5.2C9 Soelnoid valve control Solenoid valvce control TS 200 TS 800 TS 900 / 1500 RKS 51500 / 54000 max. switching capacity Watt 200 800 900/1500 1500/4000 Switch over time Sec. 1,5 40(*) 3 3 For opening delay Sec. 10 10 (*) Charging time Seite 6/ 14 TM 4021 220.100.818

Solenoid dirve MG...A with mounted control: RKS 54000 MG...A...Xn With category II3G, only permitted outside the ex zone (installation of RKS(*) separate from valve in switch cabinet) Typ MG..A.. P W Nominal current A* 24 230 VAC RKS 51500 / 54000 MG...A with mounted control: RKS 51500 MG...A...Xn With category II3G, only permitted outside the ex zone (installation of RKS(*) separate from valve in switch cabinet) Typ P Nominal current A* 019A3 4000/100 17,4/0,4 019AA3.1 3000/160 13/0,7 020A1 2000/100 8,7/0,4 020A2 3000/125 13/0,5 020A3 4000/132 17,4/0,6 MG..A.. W 24 125 018A2 1200/70 50/2,9 019A1 1200/120 50/5 019A2 1500/90 63/3,8 019A5 200/20 1,6/0,16 As per request of customer valve control RKS 51500 / 54000 for installation into switching cabinet *Amb.temp. 20 C at 100% duty cycle stationary warmed up (Amb.temp. 20 C at 0% duty cycle switch on moment / values x factor 1,25) MG...A...C With mounted control TS800C MG...A...C...Xn With category II3G, only permitted outside the ex zone (installation of RKS(*) separate from valve in switch cabinet) Typ MG..A..C P W I Nominal A* 24 Charging time sec. 16A5C6 48/20 2 40 19A5C6 48/20 2 40 16A5.2C6 72/50 3 40 19A5.2C9 72/50 3 50 RKS(*) Relais combination control; *Amb.Temp. 20 C at 0% duty cycle switch on moment. Seite 7/ 14 TM 4021 220.100.818

Standard solenoid drive IP 54 Standard solenoid drive IP 65* * compound filled with casting resin. with Harting plug HAN 7D / 8D optionally available Seite 8/ 14 TM 4021 220.100.818

Xn version IP 54 and IP 65** In accordance with DIN EN 600790, as well as the inner earth connection, version type Xn solenoid actuators have an additional outer earth connection, with a conducting connection between them. The outer earth connection is suitable for connecting a maximum of two equipotential bonding conductors, each with a cross section of up to 6mm². Minimum crosssectional area of earthing conductors Crosssectional area of the phase conductor of the installation, S mm² S 16 Minimum crosssectional area of the associated protective conductor, S mm² 16 < S 35 16 S > 35 S 0,5 S Protective conductor connection The solenoid actuator must always be integrated in the equipotential bonding. A connecting facility is available for this purpose in the vicinity of the magnetic coil connecting terminal. NOTICE! The solenoid drive must additionally be earthed via the external earthing connection on the housing. ** encapsulated with cast resin up to the terminal strip Dimensions Solenoid MG... A B ØC D E Weight in kg IP 54 IP 65 004 100 60 80 152 1,6 1,7 005 100 60 80 152 1,6 1,7 008 120 73 102 163 3,2 3,5 010 (A) 159 88 127 176 6,0 7,0 012 (A) 159 97 127 176 6,6 7,2 014 (A) 201 120 153 189 10,5 11,7 016 (A) 201 134 153 152 189 11,7 12,5 018 (A) 223 152 191 171 208 19,0 22,2 019 (A) 223 152 191 171 208 21,3 24,5 020 (A) 256 182 230 227 36,3 40,0 Seite 9/ 14 TM 4021 220.100.818

Rainproof cover standard series MG Rainproof cover explosion protection series for MG Xn version Sight ØE F MG..(A).., MG..Xn.. Sight ØE F MG..(A).., MG..Xn.. 1 170 50 004, 005 3 260 64 014(A), 016(A) 2 220 56 008, 010(A), 012(A) 4 370 50 018(A), 019(A), 020(A) Anschlussplan mit Kabelverschraubung DIN EN 50262 als standard & Xn Ausführung für Ex Version erhältlich Design Design VAC Solenoid drive MG... 004 0053 0082 010 012 014 016 018 019 020 010A5 012A5 014A5 016A 016A5 018A1 24 01 04 018A2 05 018A5 04 019A1 019A2 05 110 01 04 125 01 05 220 240 01 04 24 110 02 04 240 019A3 05 05 05 05 019A5 019A5.3 04 04 04 04 04 019A5.4 020A1 020A2 020A3 05 05 05 05 02 04 05 AP 01 AP 02 AP 04 AP 05 Seite 10/ 14 TM 4021 220.100.818

Connection plan with pinandsocket connector as per DIN EN 175301 8 (not available in Xn version) Solenoid Design Design VAC drive 24 110 125 220 240 24 110 240 MG... 38 06 06 0801 004 0053 0082 010 012 08 08 08 08 06 06 014 016 018 019 020 010A5 012A5 014A5 016A 016A5 016A5C6 016A5.2C6 07 018A1 018A2 09(*) 018A5 019A1 019A2 09(*) 09(*) 09(*) 019A3 09(*) 09(*) 09(*) 019A5 019A5C6 07 019A5.2C9 019A5.3 09(*) 019A5.4 020A1 020A2 09(*) 09(*) 09(*) 020A3 AP 08 AP 09 AP AP 06 AP 07 AP 09* * Installation of switching cabine Seite 11/ 14 TM 4021 220.100.818

Connection plan with pinandsocket connector as per DIN EN 175301801 / DIN 43652 (not available in Xn version) DIN EN 175301801 Solenoid drive MG... 004 0053 0082 010 012 014 016 018 019 020 010A5 012A5 014A5 016A 016A5 016A5C6 016A5.2C6 24 08 07 018A1 018A2 09(*) 018A5 019A1 09(*) 019A2 Design 110 08 125 08 09(*) 09(*) 220240 08 24 110 019A3 09(*) 019A5 019A5C6 07 019A5.2C9 019A5.3 09(*) 019A5.4 020A1 020A2 09(*) 020A3 AP 08 AP 10 Design VAC 010 240 010 09(*) DIN 43652 AP AP 07 AP 09 AP 09* * Installation of switching cabine Seite 12/ 14 TM 4021 220.100.818

Seite 13/ 14 TM 4021 220.100.818

Seite 14/ 14 TM 4021 220.100.818