Vickers Pressure Relief Solenoid Operated, Two-Stage Directional Control Valve DG5S4-02 Flows to 115 l/min (30 USgpm) Pressure to 210 bar (3000 psi)

Directional Valves. Pilot Operated Directional Valves. Vickers. Service Data

(F*) - DG5V -10- * - (R) - (B) - **(L) - (**) - (X) - (*) - (E) - (T) - (*) - (V)M - (S*) - * ** * * (L) - (*) ** - (***) (EN***)

Hand-operated Hydraulic Control Valve 4- way 2-position 4 Ports

LOAD SENSE SECTIONS. Series 20. Directional Control Valves NEED NEW PIC VALVES STANDARD FEATURES SPECIFICATIONS

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

HY-SPEC CATALOGUE - HYDRAULIC VALVES. Hydraulic Valves. Visit our website Catalogue

3/8 & 1/2 NPT. 4-Way - 5 Ported - 2 Position - Type 2 Use on all 4 Way - 2 Position applications

Spreader Valves SPR-2FFL12, SPR-2FFLC12 & SPR-2FFLW86

SECTIONAL BODY. Model SV. Directional Control Valves VALVES STANDARD FEATURES SPECIFICATIONS. Parallel or Series Circuit Construction ...

INSTALLATION DIMENSIONS

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported

PRESSURE CONTROLS TECNORD

Large Electronically Adjustable Proportional Pressure Compensated Flow Control Engineering & Manufacturing Solutions

Cartridge Valves Technical Information. Spreader Valves. Spreader Valves SCHEMATIC MODEL PRESSURE FLOW* WEIGHT SPR-2FFL12 SPR-2FFLC12 SPR-2FFLW86

Mini 1. Compact High Flow 3-Way and 4-Way Pneumatic Directional Control Valves

GPM PSI LPM BAR MODEL CAVITY PAGE IF-S3A special IF-S3D special IG-S4A special 198

4-Way Directional Control Valve With Hydraulic Kick Out

SV SOLENOID OPERATED

Monoblock Directional Control Valve PMB22TSTSAB PMB23TSTSTSLB PMB21TDLB

LOGIC POPPET VALVES AND CARTRIDGE MANIFOLD SYSTEMS

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

36EFC. Series & EFC Valve Package

Directional Control Valves Series D81V. General Description. Operation. Features. Specifications

Note: For use with hydraulic fluids other than those listed above, please consult Yuken representative in advance.

Directional Control Valves. General Description. Operation. Features

1 HYDRAULIC POWER UNITS

LOGIC POPPET VALVES AND CARTRIDGE MANIFOLD SYSTEMS

and RD5000 or by the Utility section in the Series 20 valves. 7. The internal pilot pressure is used to initiate the spool shift when a solenoid is en

Directional Controls

Série D3 Válvula Direcional CETOP 5 e NG 10. Catálogo HY /US

CLS100 Proportional Load Sensing Mobile Valve

Available manual, pneumatic, and hydraulic spool control kits.

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in

Manifold Specifications Stacking Type

Directional Control Valves Series D111VW. General Description. Features. Performance Curves

Service and Parts Manual. Minimum Filtration Required:

4-Way Directional Control With Pressure Compensated Flow Control PSDCF120M64LF Specifications:

Catalog HY /NA. Catalog HY /NA. Parker Hannifin Corporation Hydraulic Pump Division Marysville, Ohio USA

STC Solenoid Valve List Price

D07 & D08. Series 35 Solenoid Valves D07 D Friendship Drive, Magnolia, TX Tel.: Fax:

Solenoid Valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm) A-1.

Pilot Operated Directional Control Valves Series D31DW, D41VW - D111VW

Port Flow Rate/ Function Series Actuators Page Number Size Factor

Directional Control Valves. General Description. Features. Specifications

VSD10M DIRECTIONAL CONTROL VALVES SOLENOID ACTUATED, PILOT OPERATED

5 Port Pilot Operated Solenoid Valve Metal Seal, Plug-in/Non Plug-in. Flow characteristics (1) 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

Manifold Specifications

P.T.O. INSTALLATION 1 2 For manual shift transmissions, drain transmission fluid. For automatic transmissions, do NOT drain transmission fluid. Remove

Proportional Directional Control Cartridge Valves: PSV10-34 & PSV12-34

Directional Control Valves. Features. Application. Operation

3/8 & 1/2 NPT. with 3/8 and 1/2 NPT ports for 4 Way - 2 & 3 Position see Pg locate counterbores in body to control static squeeze on seals.

GENERAL PURPOSE. 3 Port 1/8 Pilot Valves Two Hands Safety Valve BC 1/4 Body Ported Valves : Mechanically Operated...

Pump Safety Block Model DBA... / DBAW, Series 1X

Pilot-Operated Directional Control Valves Series D3 - D11

Service Data Vickers. Directional Controls. Pilot Operated Directional Control Valves DG5S4-10**-*-*-53 I-3624-S. Revised 9/1/86

Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI

CLS180 Proportional Load Sensing Mobile Valve

Chapter 10: Valves for Pipe Mounting

DMH085** Series will be available January 1, Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO.

Power Units and Valves

Pilot Operated Directional Control Valves Series D31DW, D31NW, D*1VW

SOLENOID VALVES NFPA D03 NFPA D05 D03 & D05 SERIES 35- SOLENOID VALVES. Features. Internal Structure NFPA SIZE: D03 & D05

Directional Controls. Solenoid Controlled Pilot Operated Directional Valve. Vickers DF5S4(L)-16*A/B/C/N-(*)-(E)*-53. Service Data I 3622-S

Easytork Solenoid Valve IOM

Solenoid valves. Poppet and Spool type solenoid actuated valves for applications up to 350 bar (5000 psi) and 227 L/min (60 USgpm)

Directional Controls

DIRECTIONAL CONTROL (LD) DIRECTIONAL AND FLOW CONTROL (LD) SOLENOID OPERATED DIRECTIONAL

Nomenclature... xi Hydraulic Laws, Theorems, and Equations...xii

BW0511FP. ByWire Elements BW0511FP Flow Sharing Element Interface IBW0511

RPE3-04. Functional Description HA /2010. Directional Control Valves Solenoid Operated. Replaces HA /2007

DC Series. 4-Way Directional Control Valve With Or Without Flow Control PDC16T4PBS PDCF16TM454LF

MP18 Stacking Valve System Technical Information Manual

PACKED SPOOL 4-WAY DIRECTIONAL CONTROL VALVE.

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

Post-Compensated Proportional Valve CV2000LS

Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI

EFC. Electronically Adjustable Proportional Pressure Compensated Flow Control

Directional Controls

Modular Unit 6MB HYDRANOR MODULAR UNIT 6MB GENERAL DESCRIPTION. 6MB-200-**-2C General Arrangement. Rev

Monobloc and Sectional Directional Control Valves

Full Range Pressure Compensating Variable Flow Control

29 158/ Proportional Pressure Relief Valve Models DBE and ZDBE, Series 1X. Ordering code DBE 6 1X G24 1/ PSI (315 bar)

Chapter 6: Check Valves

PVX-11 VANE PUMPS. See pages 12 thru 14 for PVX-11 dimensions. VARIABLE DISPLACEMENT, PRESSURE COMPENSATED PERFORMANCE SPECIFICATIONS

DRV2-080 Adjustable, Direct-Acting Relief Valve

Grommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

Subplates (AP) and multi-station subplates

Lesson 5: Directional Control Valves

Contents. Directional Control Valve 2 Series CV Unibody. Page 3-4. General Information. Page 5. Technical data. Page 6. Performance Curves

5 Port Solenoid Valve

Proportional Valves. Proportional solenoid valves for pressure and flow control

Solenoid directional valves type DPHI, DPHU

Pressure Control Valves Series R. General Description. Specifications. Flow Data

FOR COMPRESSED AIR OR GAS SERVICE

directional lever control valves

ANTI-SHOCK DIRECTIONAL CONTROL VALVES

Service Data Vickers. Directional Valves. Wet Armature Solenoid Operated Directional Control Valves DG4V4-01, 1* /EN/0799/S

Transcription:

PRODUCT INFORMATION FAQ s Directional Control Valves General....... Page 2 Directional Control Valves Electric....... Page 4 Directional Control Valves Options....... Page 6 Directional Control Valves Mounting...... Page 7 Modular Control Valves.................. Page 8 Vane Pumps........................... Page 9 Carol Stream, IL 60188 Page 1 www.northmanfp.com

Directional Control Valves General What certifications do Northman valves have? We hold certifications for both CSA and CE, as well as ISO 9001. What is the seal material in the directional control valves? Buna N is standard. Viton seals are available. The circuit schematic for the spring offset and detent valves look similar to the spring centered schematics. What is the difference? The spring offset and detent valves are actually two-position valves where the valve spool travels from end-to-end passing through the center configuration. The three-position spring centered valves can stop in the center position. The solid vs. the broken box lines intend to indicate this. Do all spool designs in a valve series have the same flow and pressure ratings? No. The spool type will affect flow and pressure ratings. For example, the commonly used closed center spool, C2, for the G02 series is rated for 16.8 GPM, while the commonly used tandem spool, C6, is rated for 10.7 GPM. Check the detailed technical information in the catalog for ratings. Other than spool designs, are there other factors affecting the flow rating of valves? Yes. In some cases the type of electric supply affects the flow rating of valves. Check the detailed technical information in the catalog for ratings. Do the manually operated (hand lever) valves come with an integral relief valve? No. These are of the industrial valve design rather than the mobile type design where that feature is sometimes available. When I call about the larger G04, G06 and G10 series of pilot operated valves, what do I need to know about the part numbering system? There are actually two valves making up the pilot operated valve - the main slave valve that controls the directional flow of the oil in the system, and the smaller pilot valve that provides the hydraulic pressure to shift the main valve. The main valve has a number in the form of HPD-G06-, or HPD-G08-, or HPD-G10-, and the pilot valve has the number in the form of SWH-G02-. Together, they create a single functioning valve with the catalog part number in the form of SW-G06-, or SW-G08-, or SW- G10. It is only the complete valve part number that is stamped on the valve nameplate. If you need to identify or replace just the pilot valve, mention that when you supply us with the part number of your valve and we can reference the unique part number for just the pilot valve. Carol Stream, IL 60188 Page 2 www.northmanfp.com

What pilot valves are mounted on the main slave valves in the bigger pilot operated G04, G06 and G10 valve series? These bigger piggyback valves all use our G02 series as the pilot valve. The G04, G06 and G10 piggyback valves do not come with an integral pilot pressure check valve with the open center spool designs. How do I get sufficient pilot pressure to shift the valve if my valve has the open center spool configuration (C3, C5, C6, C60)? Use the external pilot option ( -E ). Pressure to the X port on the manifold or subplate from another source in your system will shift the valve. (See the pressure specifications in the catalog for the acceptable pressure range.) If the valve must be internally piloted in your system, then install a back pressure check valve in the tank line. (See the pressure specifications in the catalog for the acceptable pressure range.) The valve must be externally drained with this method. Can I field change the pilot configuration of my piggyback valves? Yes, both the pilot pressure and drain configurations can be independently converted between internal and external designs. See the instructional sheets on our website. Can the larger piggyback valves be outfitted with a pilot choke? Yes. The larger slave and pilot valve combinations in the G04, G06 and G10 sizes are all piloted by the SWH-G02 series valve. A meter-out modular flow control valve (MT-02W-K) can be sandwiched between the main slave valve and the pilot valve to control the rate of the pilot valve spool shift. What series directional control valve is the PB option (Push Button for the manual overrides) available on? The SWH-G02 series. What is the PT port thread designation I see on some of the valves in the catalog? The PT port thread is for an ISO designation (ISO 7/1) for tapered threads that are equivalent to DIN 2999, BSP Tr, JIS B0203, R 1/8 and R ¼ Keg, Etc. The PT thread is similar to NPT, but not interchangeable. Because the PT thread is seldom used in the US and it could be mistakenly identified as an NPT thread, it is not offered on the Northman products stocked at the North American facility. Carol Stream, IL 60188 Page 3 www.northmanfp.com

Directional Control Valves Electric What electric connections are available in AC? -10: Junction Box with1/2 NPT conduit connection, indicating light -20: Hirschman DIN connector, indicating light What electric connections are available in DC? -10: Junction Box with1/2 NPT conduit connection, indicating light -20: Hirschman DIN connector, indicating light -31: Lead wire, 11.75 long -41: Dual spades, SAE J858A In AC valves, what is the Rectified option? This is an AC voltage option. When the voltage is specified as R110, R120, R220, R240 (instead of A110, A120, A220, A240), the AC power supplied to the valve is converted to DC power. AC current is more readily available and AC solenoids have faster cycle times, but AC solenoids have a natural tendency to audibly click and under certain circumstances can emit a hum. Specifying the rectified option provides a DC operation to the incoming AC power. Can I change the solenoids on my valve so I can have a different voltage? Yes and No. You can order a replacement solenoid coil of a different AC or DC voltage, but there are limitations on interchange. The valve core is originally matched to an AC current or to a DC current. Therefore, you can replace an original AC solenoid with one of a different voltage. Likewise for the DC voltage. However, you cannot change from an AC to a DC voltage or from a DC to an AC voltage in the field by just replacing the solenoid coil. The core must be changed as well It must be remembered that the rectified AC coil has a DC solenoid core, so its interchange is with other rectified AC coils or with DC coils, not with a standard AC coil. And in reverse, a DC coil may be replaced with another DC coil or with an AC rectified coil, but not with a standard AC coil. Why do I need to know if my junction box has straight or diagonal terminals? This is only necessary if you are replacing the terminals in the G02 size valve. There were two different manufacturing designs used. Functionally they are the same. Are the directional control valves surge protected? Our valves come standard with electrical surge control. There is also a low surge voltage option ( LS) in the G02 and G03 series. The LS increases the drop-out time when the incoming electric signal is removed. This helps protect against solenoid drop-out if there is a momentarily drop in the incoming current. Carol Stream, IL 60188 Page 4 www.northmanfp.com

Directional Control Valves Electric (Cont.) Can the above LS option be added in the field? Yes. If you are converting a valve with the DIN connector, you will simply replace the DIN connector. If the valve has a junction box connection, replace the terminal blocks in the junction block. (Note: if the valve is the G02 size, you must specify which of the two types of terminals your valve has - straight or diagonal.) Are explosion proof coils available? They are not an option at this time. If I lose electric power, can I shift my valve? Yes. Manual overrides are standard. The spool can be shifted by depressing the pin in the end of the solenoid core. Carol Stream, IL 60188 Page 5 www.northmanfp.com

Directional Control Valves Options What is the Hydraulic Shockless ( M) option? The shockless valve option (sometimes referred to as soft shift ) is available in the G02 and G03 series valves only. A specially designed and machined spool minimizes an abrupt change in the flow condition at flow cut-off thus reducing the shock or bang in many hydraulic systems. Although technically the hydraulic shockless option can be specified for all voltages in the G02 and G03 series, it is more effective in the DC and rectified AC voltages. Is the Hydraulic Shockless ( M) option available on all valves? Yes, but it is commonly specified for DC coils or rectified AC coils for the maximum effect of shock dampening. It is available only in the G02 and G03 series. Spool types are limited to spring styles C2, C4, and B3 in the G02 series and to spring styles C2, C3, C4, C6, B2, and B3 in the G03 series. What is the Stroke Adjustment option? This is available for the G04 and G06 series only. The options are A, B, or AB (the ends controlling the ports). The stroke travel of the main valve spool from full stroke to the end of the valve may be adjusted in to limit the stroke. If the stroke adjustment is selected, there is an additional K option available that adds an adjusting knob to the valve end for ease in making the adjustment. Carol Stream, IL 60188 Page 6 www.northmanfp.com

Directional Control Valves Mounting How do I match a bolt kit to my directional control valve? You don t have to. The proper bolt kit comes supplied with every subplate mounted valve. However, if you are mounting modular valves in the stack of the G02 and G03 series valves, you must use a longer bolt kit and order it as a separate item. See the catalog for sizing and ordering information. Can I mount my valve in any attitude? It is recommended that all valves be mounted with the spool in the horizontal plane. It is required that valves without a spring, including detented models, be mounted with the spool in the horizontal plane. Carol Stream, IL 60188 Page 7 www.northmanfp.com

Modular Control Valves What is the seal material in the modular control valves? Buna N is standard. What directional control valve series are the modular control valves available for? The G02 and the G03 series. How do I mount my modular control valves? They are mounted in a sandwich stack between the directional control valve and the subplate or manifold. Do they come with mounting bolt kits? No. The bolt kits must be ordered separately. The length required depends on the number of modular valves mounted. See the catalog for sizing and ordering information. Are there any special considerations when mounting the modular valves? If two or more modular valves are mounted and one of them is a pilot-operated check valve modular valve, it must be mounted immediately under the directional control valve. In addition, the directional control valve must have the C4 Float Center Spool for the stack to function properly because the check valve pilots must be vented in order for the checks to be fully seated. Carol Stream, IL 60188 Page 8 www.northmanfp.com

Vane Pumps Can my cartridge kit for my vane pump be installed as either a left-hand or a right-hand rotation? No. The cartridge kit must be ordered as either a left-hand or right-hand. What is the difference between the industrial vane pump and the mobile vane pump? The industrial vane pump s 12 vane design gives it a low noise rating for industrial machinery applications. The mobile pump s 10 vane design well suits it for the higher pressure and speed demands of mobile applications. Both models use the same pump housing. Why is there a weep hole in the housing of some vane pumps and not others? The weep hole is used in the VQ series mobile pump and not in the V series industrial pump. If a housing with a weep hole is used for an industrial application, the weep hole may be plugged. What is the purpose of the weep hole in the VQ mobile series? The VQ pump is shipped with an extra shaft seal. The seal is installed at assembly when the pump is mounted to a PTO (power-take-off). The weep hole is then located between the two seals so that if there is leakage the fluid can be checked to see if it came from the PTO or the pump. Carol Stream, IL 60188 Page 9 www.northmanfp.com