Levelling valve

Similar documents
DATA PD SV13.., SV14.. Levelling Valves. Product. Function. Technical Features. Range Overview

Mounting and operating instructions EB 5801 EN. Electric Actuators Type 5801 (Rotary Actuator) Type 5802 (Linear Actuator)

Air Braking Equipment for Towed Vehicles in Accordance with Council Directive 71/320/ EEC

Steering unit LAGZ. Data sheet. Series 2 x

HPB Hydraulic Power Braking System

Fisher 1051 and 1052 Style H and J Sizes 40, 60 and 70 Rotary Actuators

Type 1051 and 1052 Diaphragm Rotary Actuators

Operating instructions FPCC FPFG FPCG FPFX FPAC

Twin Power. Manual. Pneumatic Multiturn actuator in Standard and ATEX design WARNING! WARNING! Mounting. Assembly example

Introduction. Installation. Maintenance. Bill of Materials

INSTALLATION INSTRUCTIONS

Steering unit LAGC. Data sheet

HYDRAULICS. TX420 & & lower. Hydraulic Tandem Pump Removal. 4. Remove the LH side panel (Fig. 0388).

01 09 Installation guidelines Air suspension units GL70 GL70HD GL70L GN Air suspension units GL70 GL70HD GL70L

GROUPCODE NEN : ANSI : STEEL BS : STEEL

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 852 / 0815 / E

TPV Variable Displacement Closed Loop System Axial Piston Pump THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 851 / 0813 / E

Service Bulletin No. 3033

Axial piston variable pump A4VG Series 32. Europe. RE-E Edition: Replaces:

DATA PD BS7... Spring Brakes (Disc), diaphragm/diaphragm. Product. Function. Technical Features

EUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Am Eichamt 8 DE Wertheim. Pump unit GMZ-E

TRW STEERING COLUMN MODELS CA (TILT/TELESCOPIC) AND CT (TILT ONLY) CAM REPLACEMENT KIT

Flow limiter SP/SMB US

DATA PD BR43.. Load Sensing Valve - mechanically controlled. Product. Function. Technical Features. Range Overview

Manual Flushing. I nspection and Service

Axial Piston Variable Pump A4VG

DATA PD LS1..., LS2..., LS3... Lift Axle Valves - Pneumatic. P r o d u c t. Function. Technical Features

Brake System H TX, H2.0TXS [B475]; H TX [B466] Safety Precautions Maintenance and Repair

Axial Piston Fixed Motor A2FNM for Fan Drives and Flywheel Mass

1 of 11 4/11/ :35 AM

Steering unit LAGU. Data sheet

Fisherr 1051 and 1052 Diaphragm Rotary Actuators

Axial piston fixed motor A2FM Series 70 A2FE Series 70

INSTALLATION INSTRUCTIONS. Put this information in the glove box with the vehicle owner's manual. PARTS LIST INSTALLATION

EB EN. Type 3372 Electropneumatic Actuator. Translation of original instructions

Caliper Bushing Inspection & Replacement. DB 22 Serial Number , DB 22 LT Serial Number , Manufactured after May 3rd, 2010

SPARE PARTS LIST RIDERS RIDER 111 B, , , , ,

Axial Piston Variable Pump A2VK

Axial Piston Fixed Pump A17FNO Series 10

CARBURETION. Tank Mount, Horizontal Crankshaft. Vacu-Jet - All

Fisher 1052 Size 20 Diaphragm Rotary Actuator with F and G Mounting Adaptation

88cc Big Bore Kit Install Instructions

INSTALLATION INSTRUCTIONS. Put this information in the glove box with the vehicle owner's manual. INSTALLATION PARTS LIST

Radial piston hydraulic motor Hägglunds CAb

ENGINE TUNE-UP INSPECTION OF ENGINE COOLANT INSPECTION OF ENGINE OIL INSPECTION OF BATTERY. INSPECTION OF AIR FILTER (Paper Filter Type)

Flow limiter SP/SMB10 Dual flow series

FPO 80 FPOC FPOS FPON, FPOS Tank truck vane pump

Excluding vehicles with special bodywork, 4MATIC, sedan with long wheelbase and all types without level control system on the rear axle and

Type 1051 and 1052 Size 33 Diaphragm Rotary Actuator

Axial piston variable pump A10VSO series 32. Americas. RE-A Issue: Replaces:

Mounting and Operating Instructions EB 5868/5869 EN

Rheometer Calibration Fixture Instruction Manual Model 280 & 286

Product Manual. S&S V-100 Ball Valves 2 though 8 Inch Designs. Introduction: Installation:

Rotary inlets for pressurised oil, compressed air

BPW height-adjustable drawbars

Mounting and operating instructions EB EN. Differential Pressure and Temperature Regulator with Flow Limiter Type 2479/2430 K

Removing and installing cylinder head

Service Manual Truck and Trailer Applications. AA1 Automatic Brake Adjusters

Type 1051 and 1052 Diaphragm Rotary Actuators

Version VDL Weweler b.v. Maintenance & Installation Manual

Fisher 1061 Pneumatic Piston Rotary Actuator with Style H & J Mounting Adaptations

REPLACEMENT HINT: 11. REMOVE V RIBBED BELT TENSIONER ASSY (a) Remove the 5 bolts and V ribbed belt tensioner.

Product Description. Product Numbers. Warning/Caution Notations. Required Tools. Wiring. Prerequisites

Variable Displacement Plug-In Motor A6VE

Actuators for air dampers and control valves of oil burners

LKS 160 FOR AIR DAMPERS ON MULTI-STAGE AND MODULATING BURNERS

SPARE PARTS LIST FRONTRIDERS FR2312 MA, , ,

Flow limiter SP/SMB13 for line installation in circulating-oil lubrication systems.

Steering Column Assembly, Douglas Autotech Tilt/Telescoping 46.02

Illustrated Parts List to

D58 Series Brake Instructions

M-B Companies, Inc. 5-10A Walk-Behind Paint Striper Specifications

Axial Piston Variable Pump A10VSO

1180, 1180DT, 1280, 1280DT, 1380, 1380DT, 1580, 1580DT, 1880 & 1880DT

S-ABA Service Manual. Self-Setting Automatic Brake Adjusters

Valtek Auxiliary Handwheels and Limit Stops

Operating Instruction

Installation Instructions : Ford Focus MK3 RS : Page 1 Tools Required: Philips screwdriver, trim removal tool, Torx, 10mm socket

Hydraulic pump HP-1. Type 1. Type 2

Axial piston variable pump A10VSO series 32

DISASSEMBLY. Transmission. 2. Remove the 4 clutch housing bolts. Separate the clutch housing from the transmission.

1993 ACCESSORIES & EQUIPMENT Volkswagen Power Sun Roof. Volkswagen; Corrado SLC, EuroVan, Golf, GTI, Jetta, Passat

Pull out clutch E snap ring and withdraw complete clutch pack of clutch E. 6 HP 26 ZF Getriebe GmbH Saarbrücken CD

Axial piston variable pump A10V(S)O Series 31

Pneumatic Butterfly Valve Pfeiffer Type BR 14b/AT

Axial piston variable pump A4VG Series 40

Mounting and Operating Instructions EB 8135/8136 EN. Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil

Front brakes, servicing

Axial piston variable pump A10VSO Series 31

Axial Piston Variable Pump AA4VG

Unit: mm (in) ITEM STANDARD LIMIT IN. 33 (1.3) EX.

G1/8-3/2-Way Valves - Series K9

Manual Proportional Directional Control Valve (with Pressure Compensation, Multiple Valve Series)

BRAKE SYSTEM Article Text 1996 Toyota RAV4 For Copyright 1998 Mitchell Repair Information Company, LLC Wednesday, September 13, :30PM

Winding technology, pneumatically actuated tension brakes

1, 2, 4, 6, 8, 10 and 12 in. (50, 100, 150, 200, 254, 300 mm) for all models Clevis Ends

Pedal, Assembly, Controls Group 29

A comprehensive range of pneumatic actuators, providing compact, reliable and economical powered operation for all types of quarter-turn valves

26/01/2017 3GR-FSE ENGINE MECHANICAL: ENGINE UNIT: DISASSEMBLY; 2006 MY GS300 [01/ ]

Operating Instructions ROCO Butterfly Valve with SKG Slider-crank Mechanism, with Electric Multi-turn Actuator

Transcription:

Levelling valve 464 006 Application Purpose Maintenance Vehicles with conventionally controlled air-suspension. Control of a constant ride height of the chassis by charging the air-suspension while compressing (loading the vehicle) and by venting when releasing. The height measurement is done via the angle of the lever and linkage connected with the axle. Height limitation: The levelling valves 464 006 100 0, 464 006 101 0 and 464 006 201 0 have an additional 3/2-way valve that closes as of a certain adjustable lever angle and switches to a venting function upon actuating the lever again. This "Height limitation" prevents the vehicle from being raised above a permitted level with the rotary slide valve. Zero point adjustment: The ride height can be adapted to special application conditions of the vehicle with an operating cylinder integrated in the linkage. Special maintenance that extends beyond the legally specified inspections is not required. 1

Installation dimensions 464 006 002 0 Legend 1) Vent 2) Operating range 3) Pressurizing 4) Fixing the valve in end position with 7 bar supply pressure and 3 bar bellows pressure with Ø 3h8 or parallel pin Ø 3h8x 24 DIN 7 Connections 1 Energy supply (Reservoir) 3 Exhaust 21/22 Energy delivery (Air suspension bellows) Port threads M 12x1.5-12 deep 2

Installation dimensions 464 006 100 0 View X Connections 1 Energy supply (Reservoir) 21/22 Energy delivery (Air suspension bellows) 3 Exhaust 12 Energy supply (Supply) 23 Energy delivery (Rotary slide valve) Port threads 1, 21, 22 M 12x1.5-12 deep 12, 23 M 16x1.5 3

Levelling valve 464 006... 0 Linkage 433 401 003 0 The linkage 433 401 003 0 must be ordered separately. Legend α Deflection of the levelling valve lever max. 45. A A is the dimension between axle mounting point and the connection to the levelling valve lever (α-character). L Lever length (at least 150 mm) For adjusting the valve at the vehicle it is decisive which total spring travel the axle permits. Approximate value: The ratio "lever length L / rod length A" should be 1.2 if the closing angle of maximum 45 is not exceeded. The lever length L should be 150 to 295 mm. If a shorter lever has to be used, a higher air consumption of the levelling valve has to be concerned. Installation recommendation and setting information Fasten the levelling valve vertically or horizontally with two M8 bolts on the chassis. The drain must point downwards. To make installation and setting of the lever and linkage easier, you can insert a Ø 3h8 locator pin or a Ø 3h8 x 24 DIN 7 parallel pin into neutral position to position the air-suspension valve shaft (see previous installation dimensions). Install the linkage if the vehicle is positioned at normal level. The linkage has to be aligned vertically. Mount the levelling valve at maximum lever length if possible. You can clamp the lever at the desired length with the hexagon head bolt seated on the fastener for the round bar. Depending on the fitting position various cranks of the lever are possible. 4

By accordingly fixing or turning the lever for 180 the levelling valve can be optionally operated from right or left. Depending on the final installation position - vertical or horizontal - the lever is to be inserted through one of the two bores in the operating shaft which are offset by 90 to one another. The levelling valve 464 006 100 0 is set to a closing able of 30 ±2 in the factory. The setting adjustments lie between 15 and 45. A closing angle of < 15 is not permitted. Note the adjustment data of the vehicle manufacturer when replacing. For adjustment of the closing angle the rubber plug underneath the 3/2- Directional Control Valve has to be removed to adjust the adjusting screw with a Torx T30 screwdriver: Counterclockwise means a reduction of the closing angle, clockwise means an increase. One rotation means an approx. 13 angle change. The following table can be used to define the height increase of the vehicle up to shutting the supply air off to the rotary slide valve as a function of the closing angle and for determining the lever length. After the vehicle has been lowered to its buffers with the help of a rotary slide valve, measure the height of the chassis. Then raise the chassis with the rotary slide valve. If the permissible full suspension travel is achieved before the height limitation of the levelling valve is applied, cancel the raising process and lower the vehicle. Turning the set screw counterclockwise reduces the closing angle and also the suspension travel. If the height limitation sets in before the chassis is at the required hub height, the vehicle has to be lowered slightly as well in this case. Turning the self-locking set screw clockwise increases the closing angle and the suspension travel. Repeat the process until the required suspension travel (equal or less than the maximum suspension travel specified by the axle manufacturer) is achieved. Adjustment values Lever length L [mm] Hub height H [mm] α = 15 α = 20 α = 25 α = 30 α = 35 α = 45 125 32 43 53 62 72 88 150 39 51 63 75 86 106 175 45 60 74 87 100 124 200 52 68 84 100 115 141 225 58 77 95 112 129 159 250 65 85 106 125 143 177 275 71 94 116 137 158 194 295 76 101 125 147 169 209 5

Hub height H [mm] Lever length L [mm] α = 15 α = 20 α = 25 α = 30 α = 35 α = 45 50 193 146 118 100 87 71 60 232 176 142 120 105 85 70 271 205 166 140 122 99 80 309 234 189 160 140 113 90 263 213 180 157 127 100 293 237 200 174 141 110 260 220 192 156 120 284 240 209 170 130 308 260 227 184 140 280 244 198 150 300 262 212 160 279 226 170 297 241 180 255 190 269 200 283 Technical data Order number 464 006 002 0 464 006 100 0 464 006 101 0 464 006 102 0 464 006 201 0 3/2 directional control valve No Yes Yes No Yes Max. operating pressure 13 bar Max. dynamic bellows pressure 15 bar Permissible medium Air Operating temperature range -40 C to +80 C Linkage Round bar Ø 6 mm Nominal width Levelling valve 2x Ø 3 mm Nominal width Shut-off valve Ø 6 mm Weight 0.41 kg 0.51 kg 0.51 kg 0.53 kg 0.70 kg Quickfit connections 5x Ø8x1 5x Ø8x1 For the zero point adjustment on the levelling valve, the following operating cylinders can be used: 421 410 023 0, Hub 25 mm 421 410 054 0, Hub 45 mm 421 411 304 0, Hub 85 mm; with piston rod facing upward, use bellows (Accessories pack 421 411 530 2) 6

Operation With increasing load, the chassis moves down with the levelling valve fastened to it. The connection between the vehicle axle and the levelling valve presses upon the lever (f) and the guide (d) upward via the cam (e) during the process. The tappet seated on the guide opens the inlet valve (b) at the same time. The compressed air fed into the device from the supply reservoir via connection 1 and the check valve (a) can now flow into the levelling bellows via connections 21 and 22. To reduce air consumption to a minimum, grooved windings on the tappet change the crosssection of the air openings in 2 stages according to the size of the lever deflection. The end position of the valve is achieved by means of raising the trailer box resulting from filling the bellows and closing the inlet valve (b) controlled by lever (f). In this position, connections 21 and 22 are connected with one another through a cross flow throttle. The process is reversed upon relieving the load on the vehicle. The vehicle construction is now raised by the suspension bellows that are applied with too much pressure and the lever (f) with the cam (e) and the guide (d) pulled down. This lowers the tappet from its sealed seal on the inlet valve (b) so that the excess air can flow to atmosphere from the suspension bellows via the vent hole (c) of the tappet and the vent openings 3. The resulting lowering of the box moves the lever (f) back to its normal horizontal position. Closing the vent hole (c) by setting the tappet on the inlet valve (b) puts the levelling valve back into its end position. 7