Model Specifications V400S V400D Sensor Code Sensor Diameter 7/16 (11mm) 7/8 (22mm) 1-3/8 (35mm) 7/8 (22mm) 1-3/8 (35mm) Accuracy

Similar documents
V200S. ±1% of flow rate; up to +/-0.5% if calibrated ANSI Class* 600# 150# 150# 600# 600# Drive Rods Single Double (150mm-1050mm)

V550 Spring Lock Flanged Connection with Packing Gland

Regular Models. V150 Spring Lock Threaded Components

V400D VERIS Verabar (Double Rod) Installation and Maintenance Manual

V500 and V510 VERIS Verabar Installation and Maintenance Manual

V200D VERIS Verabar (Double Rod) Installation and Maintenance Manual

VERIS FLOW MEASUREMENT GROUP

VERIS VERABAR VELOCITY AVERAGING FLOW SENSORS TRUE PERFORMANCE IN FLOW MEASUREMENT

VERIS FLOW MEASUREMENT GROUP

V150 VERIS Verabar Installation and Maintenance Manual

Accutubes. Accuracy True double averaging design +1% of rate accuracy +0.1% repeatability Tested and certified by independent flow labs

Verabar Velocity Averaging Flow Sensors. True Performance in Flow Measurement


KB Series self averaging pitot flowmeter for gas, liquids and steam flows

Averaging Pitot Tube Flowmeter Catalogue ED IN AUSTRALIA

Rosemount 3051CFA Annubar Flowmeter

Rosemount 1195 Integral Orifice Primary Element

User Guide IM/TORBAR-EN Rev. D. Averaging pitot tubes

Instrument Manifolds. V, VB, and VL Series. 2-, 3-, and 5-valve instrument manifolds

Rosemount 485 Annubar Pak-Lok Assembly

Manifold and Isolation Valve Mounting System for Direct Mounting DP Transmitters

Rosemount 285 Annubar Primary Element Series

Mid-West Instrument FLOW MEASUREMENT PRODUCTS PRECISION FLOW TEST KITS VERABAR FLOW SENSORS

ABB MEASUREMENT & ANALYTICS DATA SHEET. FPD350 Torbar Averaging pitot tubes

ORIFICE PLATE flow meters

FPD350 Torbar Averaging pitot tubes

Toroidal Conductivity Sensor

OAKLEAF INVESTMENT HOLDINGS 52 (Pty) ltd

F-2700 SERIES INSERTION VORTEX FLOW METER

IFOA Integral Flow Orifice Assembly

Instrument Manifold Systems

Table of Contents. Section 5: Installation Installation Procedure Pipe Preparation... S.l Accelabar Installation

Rosemount TM 222 Toroidal Flow-Through Conductivity Sensor. Instruction Manual LIQ-MAN-222 Rev.D June 2017

Rosemount 3051 Pressure Transmitter

PRESSURE GAUGES DIAL THERMOMETERS PRESSURE & TEMP. SWITCHES PRESSURE & TEMP. TRANSMITTERS PIPES, PIPE FITTINGS & FLANGES

3. MECHANICAL SEALS GROUP 3.1 MECHANICAL SEALS 3.2 FLUSHING PLANS

FICHA TÉCNICA DE PRODUTO

Micro Motion Model D and DL Coriolis Flow and Density Meters

Rosemount 3051T In-Line Pressure Transmitter

Engineered for control from tap to transmitter

Rosemount DP Flowmeters and Primary Elements

F-1500 SERIES INSERTION TURBINE FLOW METER

Armstrong In-Line and Insertion Vortex Flow Meters

VF Series High-Pressure, High-Temperature Butterfly Valves

Technical Manual MSI Hydraulic Adjustable Choke

Armstrong Double Duty 6 Steam Trap/Pump Combination Installation and Maintenance

Description of Bolt Torque Tables

Rosemount DP Flowmeters and Primary Elements

Datasheet Rev.3 Feb 2015 Venturi tube

Type 8510 and 8510B Eccentric Disc Control Valves (EMA)

Annubar Flowmeter Series

F-2600 SERIES INLINE VORTEX FLOW METER

Valves and manifolds

DRAWING INDEX 1 07/01/2013. Company Project Project Number Location Revision Date

87A-200 Series. Stainless Steel ANSI Class 150 Flanged Full Port Ball Valve - 1/2 through 1 STANDARD FEATURES STANDARDS COMPLIANCE

Thermowell For sanitary applications Model TW61, for orbital welding

310 Wafer high performance butterfly valve 312 Lugged high performance butterfly valve

CONSTRUCTION MATERIAL 2 HOW TO ORDER 2 DESIGN FEATURES 3 PRODUCTS INDEX 4

PRESSURES TO 740 PSIG (51 BARG) TEMPERATURES TO 800 F (427 C) MODELS. 300Y Series Ordering Code. Add l Inlet Size Model Body Dash Perf Mesh Require-

F-2700 SERIES INSERTION VORTEX FLOW METER

KDM ARMORED FLOW METER & SWITCH

Powers Controls TT 184 Temperature Transmitters

Features/Benefits INSTALL IT & FORGET IT FEATURES & BENEFITS

ANDERSON GREENWOOD M4AP/M4TP STATIC PRESSURE MANIFOLDS

KEYSTONE FIGURES 310/312 K-LOK BUTTERFLY VALVES

VORTEX IN-LINE FLOW METERS

Carbon Steel ANSI Class 150 Flanged Full Port Ball Valve -

Thermowell For sanitary applications Model TW61, for orbital welding

Rosemount DP Flowmeters and Primary Elements

Thermowell For sanitary applications Model TW61, for orbital welding

Rosemount 485 Annubar Threaded Flo-Tap Assembly

Rosemount 285 Annubar Pak-Lok Assembly

Variable Area Flowmeters Ori-Flowrator TM Meters

310 Wafer high performance butterfly valve 312 Lugged high performance butterfly valve

Vortex In Line Flow Meter

INSTALLATION INSTRUCTIONS 3-POSITION GATE VALVES SIZES Read All Instructions Prior To Installation

Meter, PD Series, K12-S1, S3, S5, S6 and S7

Keystone Figures 310/312 K-LOK Butterfly Valves

MANIFOLDS VALVE. Mfg & Exp. : Valves & Fittings. A Trusted Name in Valves and Fittings ISO 9001:2008 COMPANY. Catalogue No.

Model CO Compact Orifice for use with Foxboro Differential Pressure Transmitters

Orifice Flange Union Assembly and Orifice Run Installation and Operation Manual

Multivariable Vortex Flow Meter

Product Data Sheet , Rev GA Catalog Content

Industrial Pt100 RTD's

mass flowmeter for compressed air

Smith Meter PD Meter Meter, PD Series, K12- S1, S3, S5, S6, and S7

McCannalok HIGH PERFORMANCE BUTTERFLY VALVE OPERATION AND MAINTENANCE MANUAL. The High Performance Company

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

Thermowell For sanitary applications Model TW61, for orbital welding

ANDERSON GREENWOOD SERIES 500 PILOT OPERATED SAFETY RELIEF VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

High Lift Flange Weld/Test Plug (3/4"-8") - Technical Specifications

Signet 2517 Brass Paddlewheel Flow Sensor * *

RCM. Direct Reading Flowmeter. for Liquids or Gases

Promass Q for the process industry

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.

Rosemount 3051 Pressure Transmitter

Anderson Greenwood M4TL Liquid Level Manifolds

SECTION METERS AND GAGES FOR HVAC PIPING

Series W&T Pneumatic Control Valve Type RVG Globe valve and angle valve

Digital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series

Transcription:

VERIS Verabar Hot Tap Models V400 Screw Drive Flanged Components The Most Accurate and Reliable Technology for Measuring Gas, Liquid and Steam Developed from aerospace technology, the VERIS Verabar averaging pitot flow sensor provides unsurpassed accuracy and reliability. With its solid, one-piece construction and bullet shape, the VERIS Verabar makes flow measurement leak resistant and precise. The unique sensor shape reduces drag and flow induced vibration. The location of the low-pressure ports significantly reduces the potential for clogging and improves signal stability. V400S V400D Pipe Connection Flanged V400 Hot Tap Mounting Type Flanged ball or gate access valves Features and Benefits Applications Special Designs - Consult Factory Installation, insertion & retraction without system shutdown Economical single threaded rod for most applications Two threaded rods for high pressures Synchro drive simultaneously rotates both rods (double rod drives only) Patented, anti-seize orbital bearing aligns threaded rods and eliminates galling Can mount to existing flanges or valves Air Natural gas Water (raw, cooling, feedwater) Hydrocarbon liquids and gases Hazardous fluids Steam Custom mounting, lengths, materials, instrument connections, etc. Short straight run Temperature Pressure Limits (ANSI Class)* 275 psig @ 100 F (19 bar @ 38 C) 80 psig @ 800 F (5.5 bar @ 426 C) 1440 psig @ 100 F (99.3 bar @ 38 C) 825 psig @ 800 F (56.9 bar @ 426 C) Model Specifications V400S V400D 05 10 15 10 15 Diameter 7/16 (11mm) 7/8 (22mm) 1-3/8 (35mm) 7/8 (22mm) 1-3/8 (35mm) Accuracy * DIN and JIS flanges available. Consult factory. ±1% of flow rate; up to +/-0.5% if calibrated ANSI Class* s Single Double Pipe Size 2-6 (50mm-150mm) 6-42 (150mm-1050mm) 12-60 (300mm-1500mm) 6-42 (150mm-1050mm) 12-60 (300mm-1500mm) Instrument Connection 1/2 NPT or Direct Mount 1/2 NPT or Direct Mount Components Furnished Weld coupling, weld neck flange, access valve, gaskets, studs & nuts Flange Size 1 1-1/2 2 1-1/2 2

VERIS Verabar Hot Tap Models 1. Enter Pipe Dimensions or Duct Dimensions H W ID Wall Dimension Verabar spans (H) or (W) Pipe Size Sch Pipe ID and Wall Pipe Material Height (H) Width (W) Wall Duct Material Synchro-Drive (Option SYN) Synchro-Drive Description Designed for pressures greater than ANSI Class, Synchro-Drive is equipped with two drive rods that are coupled together by a protected chain drive system. Turning either drive nut simultaneously rotates both rods. Drive Nut Drive Chain 2. Pipe or Duct Orientation (Check one box) Protective Chain Shroud Anti-Seize Orbital Bearing (H) Horizontal (V) Vertical 3. Enter Flow Conditions Short Straight Run Consult Factory Synchro-Drive Benefits *U.S. Patent 5,410,920 95% faster and easier insertion and retraction. Equal load distribution over both rods maintains sensor alignment and eliminates binding. Fluid Name: Maximum Nominal Minimum Units Flow Rate All Fluids Gas Liquid Steam Pressure @ Flow Temperature @ Flow Specific Gravity, or Molecular Weight Specific Gravity VeraCalc Program can calculate Density from Temperature and Pressure 4. Select Model from Page 3 Use the Ordering Information table on Page 3 to determine your model number. 5. Flow Calculation All VERIS Verabar applications require a flow calculation to verify the DP, pressure and temperature limits, structural limits and to size the transmitter. VeraCalc is for use by representatives and end users. It is easy to operate and includes steam tables. 2 Designs, materials, weights and performance ratings are approximate and subject to change without notice.visit armstronginternational.com for up-to-date information.

Drive Nut Instrument Head Plate Packing Bolts Packing Gland Jam Nut Access Nipple Stop Nut Cover Tube Access Valve Mounting Flange V400S (Single Rod) Plate Instrument Head Drive Nut Packing Bolts Jam Nut Stop Nut Packing Gland Access Nipple Cover Tube Access Valve Mounting Flange V400D (Double Rod) 3

Model Hot Tap Screw Drive V400S Single Rod, Insert/Retract, General Purpose (05 Class, 10 and 15 Class ) V400D Double Rod, Insert/Retract, Higher Pressures ( max.) (10 and 15 only) Pipe Size and Schedule or Exact ID and Wall Thickness Pipe Size Range 05 2 to 6 (50mm to 150mm) 10 6 to 42 (150mm to 1050mm) 15 12 to 60 (300mm to 1500mm) Pipe Orientation H V Horizontal Vertical Instrument Connections (Select Remote or Direct Mount) (Transmitter sold separately) Remote Mount Transmitter (1/2 NPT) Direct Mount Transmitter (Flanged 450 F/232 C Max.) Parallel Regular RTD* Valve Transmount Mass Transmount* Manifold RTD P R D T F G M Instrument Valves (Opt.) Manifolds (Optional) Remote Mount Direct Mount Needle Gate 3-Valve 5-Valve 1/2 NPT 1/2 NPT Soft Seat Hard Seat Soft Seat C2NC() C2NS() C2GC() C2GS() F3SC() F3() F3HC() F3HS() F5SC() F5() Hard Seat F5HC() F5HS() Optional Mounting Assembly Select Valve Type, Material & ANSI Class (Includes valve, WN flange, weld coupling, spiral-wound gaskets, studs & nuts) Ball Valve Flange (Valve Size) 05 (1 ) 10 (1-1/2 ) 15 (2 ) B4CF15 B4SF15 B6CF15 B6SF15 B8CF15 B8SF15 B4CF30 B4SF30 B6CF30 B6SF30 B8CF30 B8SF30 Gate Valve Flange (Valve Size) 05 (1 ) 10 (1-1/2 ) 15 (2 ) G4CF15 G4SF15 G6CF15 G6SF15 G8CF15 G8SF15 G4CF30 G4SF30 G4CF60 G4SF60 G6CF30 G6SF30 G6CF60 G6SF60 G8CF30 G8SF30 G8CF60 G8SF60 Material & ANSI Class Material & ANSI Class SYN WPS Options Synchronized Two Rod Drive System (Available for V400D-10 and V400D-15 sensors only) Wetted Components (Furnished with weld coupling, flanges & access nipple). Must be ordered with access valve. V400D 8 sch40 10 H R C2NC G6CF30 Typical Model Number 4 * For high pressure (>500psig) or high temperature (>500 F), remote mount RTD in a thermowell is preferred. Assuming adequate heat dissipation for transmitter. Designs, materials, weights and performance ratings are approximate and subject to change without notice.visit armstronginternational.com for up-to-date information.

Instrument Head () See options on ordering information page. VERIS Flow Measurement Group armstronginternational.com/veris VERIS Verabar V400 Single & Double Rod, Flanged DATE: 09/20/01 DWG. No. SUB-3939 Scale: NTS Rev: A Page 1 of 1 Armstrong VERIS Flow Measurement Group 6315 Monarch Park Pl, Niwot, CO 80503 - USA Phone: 303-652-8550 Fax: 303-652-8552 armstronginternational.com 1636-EN Printed in U.S.A. - 8/24/16 2016 Armstrong International, Inc.