Working from 0 bar up Short switching times Suited for fine vacuum down to 1,33 10-3 mbar Assembled oil and grease-free For a.c. solenoid systems with integrated rectifier (40 to 60 Hz) These solenoid valves are ATEX and FM, CSA, XP approved Technical data Medium: Neutral gaseous and liquid fluids Operating pressure: 0 to 18 bar Flow direction: Fixed Mounting position: Optional, preferably with solenoid on top Fluid temperature: -25 to +80 NBR (Perbunan) -10 to +120 FPM (Viton)* -40 to +140 EPDM -10 to +180 FFPM (Kalrez) * For water +90 Ambient temperature: Depending on solenoid system -25, -40 to +55, +80, +100 Consult our Technical Service for use below +2 Materials Housing: brass Seal: NBR (Perbunan) Inner parts: brass, steel 1.4104/430F Alternative models with low power consumption for higher temperatures for outdoor application For fluid temperatures from -40 to +180 Seat seals FKM, EPDM, FFKM For contaminated fluids installation of an upstream filter is recommended. group Port size Function Orifice (mm) Operating pressure (bar) 13B G1/4 Universal 2 0... 10 0,12 0,32 1 9600210xxxx***** 13D G1/4 NC 2 0... 18 0,12 0,52 1 9603240xxxx***** 13CG1/4 NC 3 0... 6 0,20 0,32 1 9600320xxxx***** 13D G1/4 NC 3 0... 14 0,20 0,52 1 9600340xxxx***** 16CG1/4 NC 4 0... 8 0,35 0,52 2 9601430xxxx***** 16D G1/4 NC4 0... 10 0,35 0,52 1 9601440xxxx***** 16D G1/4 NC 5 0... 7 0,45 0,52 2 9601540xxxx***** 13B G1/4 NO 2 0... 9 0,10 0,50 3 9602210xxxx***** 13D G1/4 NO 3 0... 9 0,16 0,70 3 9602340xxxx***** 16D G1/4 NO 4 0... 6 0,30 0,70 3 9602440xxxx***** 13B 1/4 NPT Universal 2 0... 10 0,12 0,32 1 9603210xxxx***** 13C1/4 NPT NC 3 0... 6 0,20 0,32 1 9603320xxxx***** 13D 1/4 NPT NC 3 0... 14 0,20 0,52 1 9603340xxxx***** 16C1/4 NPT NC 4 0... 8 0,35 0,52 2 9604430xxxx***** 13B 1/4 NPT NO 2 0... 9 0,10 0,50 3 9605210xxxx***** 13D 1/4 NPT NO 3 0... 9 0,16 0,70 3 9605340xxxx***** 16D 1/4 NPT NO 4 0... 6 0,30 0,70 3 9605440xxxx***** xxxx Insert solenoid codes from table below. ***** Insert voltage codes from table below * Cv (US) Ÿ kv x 1,2 Options selector Material Seat seal Substitute NBR (Perbunan) 0 EPDM 1 FKM (Viton) 2 FFKM (Kalrez) / O-ring FKM 4 s See solenoid tables Accessories Substitute kv value m 3 /h* 960XXX Cable glands EEx e, EEx d (ATEX), Ms nickel plated brass Drawing no. Other voltages on request Substitute 02400 24 V a.c. 02450 110 V a.c. 11050 23050 Connectors EEx e 0588819 (for solenoid 42xx /46xx M20 x 1,5) 0570275 EEx d 0588851 (for solenoid 46xx M20 x 1,5) EEx d, EEx e 0588925 (for solenoid 46xx 1/2-14 NPT) 104 www.norgren.com/fc/en104
actuators 13B 8,0 331 IP 65-25... +60 DIN EN 175301-803 0,15 8 1 0246 7) 9,2 40 IP 65-25... +60 DIN EN 175301-803 0,16 9 7 3206 7) 8,0 331 II3G EEx na II T4-20... +60 DIN EN 175301-803 0,16 8 1 3216 II3D IP 65 T 110Form A with special screw 9,2 40 II3G EEx na II T4-20... +60 DIN EN 175301-803 0,16 9 6 3218 II3D IP 65 T 110Form A with special screw 6,9 289 II2G EEx m II T4-20... +60 3 m cable 0,40 12 4 0292 II2D T 110 1) 8,7 34 II2G EEx m II T4-20... +60 3 m cable 0,40 12 7 0293 II2D T 110 2) 3,9 162 II2G EEx me II T4 T6: -40...+55 M20 x 1,5 6) 0,50 13 4 4210 8) II2D T4: -40... +80 T 110 2) 5,3 23 II2G EEx me II T6/T4 T6: -40...+55 M20 x 1,5 6) 0,50 13 7 4211 8) II2D T4: -40... +80 T 130 2) 3,9 162 II2G EEx md IIC T6: -40...+55 1/2-14 NPT 6) 0,80 14 4 4610 8) II2D T6/T4 T4: -40... +80 EEx me II T6/T4 5,3 23 II2G EEx md IICT6: 1/2-14 NPT 6) 0,80 14 7 4611 8) II2D T6/T4-40...+55 T6/T4-40... +80 3,9 162 II2G EEx md IICT6: M20 x 1,5 6) 0,80 14 7 4612 8) II2D T6/T4-40...+55 T6/T4-40... +80 5,3 23 II2G EEx md IICT6: M20 x 1,5 6) 0,80 14 7 4613 8) II2D T6/T4-40...+55 T6/T4-40... +80 5,3 23 Div. 1 and 2-20... +60 Flying leads 450 mm 0,50 15 1 3722 CI.II, Gr.E-G, 4,4X, 6,6P, 5,3 23 Div. 1 and 2-20... +60 Flying leads 450 mm 0,50 15 5 3723 CI.II, Gr.E-G, 4,4X, 6,6P, 1) Category II 2 GD, EC-Type Examination Certificate KEMA 02 ATEX 1347X 6) Connector/cable gland not supplied, see Accessories table s and circuit s, see 105
actuators 13C 106 1) Category II 2 GD, EC-Type Examination Certificate KEMA 02 ATEX 1347X 6) Connector/cable gland not supplied, see Accessories table 12,1 15,0 504 68 IP 65-25... +60 DIN EN 175301-803 0,117 8 1 0200 7) 9,2 40 IP 65-25... +60 DIN EN 175301-803 0,160 8 5 3206 7) 11,3 49 IP 65-25... +60 DIN EN 175301-803 0,160 9 6 3204 7) 12,1 504 II3G EEx na II T4 T4: DIN EN 175301-803 0,127 9 1 3217 II3D IP 65-20... +60 Form A with special screw T 130 11,3 49 II3G EEx na II T4 T4: DIN EN 175301-803 0,170 8 6 3219 II3D IP 65-20... +50 Form A with special screw T 120 10,7 446 II2G EEx m II T4 T4: 3 m cable 0,400 12 4 0290 II2D -20... +50 T 110 1) 12,4 54 II2G EEx m II T4 T4: 3 m cable 0,400 12 7 0291 II2D -20... +50 T 110 1) 8,9 369 II2G 2) EEx me II T5: M20 x 1,5 6) 0,500 13 4 4220 8) T4: T 130 2) -40... +65 10,0 43 II2G EEx me II T5: M20 x 1,5 6) 0,500 13 4 4221 8) T4: T 130 2) -40... +65 8,9 369 II2G EEx md IICT6: 1/2-14 NPT 6) 0,800 14 4 4620 8), 10,0 43 II2G EEx md IICT6: 1/2-14 NPT 6) 0,800 14 7 4621 8), 8,9 369 II2G EEx md IICT6: M20 x 1,5 6) 0,800 14 4 4622 8) ) 10,0 43 II2G EEx md IICT6: M20 x 1,5 6) 0,800 14 7 4623 8) 8,9 369 Div 1 and 2-20... +60 Flying leads 450 mm 0,500 15 1 3724 CI.I, Gr. A-D, 9,5 41 Div 1 and 2-20... +60 Flying leads 450 mm 0,500 15 5 3725 CI.I, Gr. A-D, s and circuit s, see
actuators 13D 6) Connector/cable gland not supplied, see 'Accessories' table 16,9 703 IP 65-25... +60 DIN EN 175301-803 0,270 10 1 0700 7) 17,3 75 IP 65-25... +60 DIN EN 175301-803 0,320 11 6 3703 7) 11,4 475 II2G EEx me II T5: M20 x 1,5 6) 0,500 13 4 4230 8) T4: T 130 2) -40... +50 15,2 66 II2G EEx me II T5: M20 x 1,5 6) 0,500 13 7 4231 8) T4: T 130 2) -40... +50 11,4 475 II2G EEx md IIC T5: 1/2 x 14 NPT 6) 0,800 14 4 4630 8) 15,2 66 II2G EEx md IIC T5: 1/2 x 14 NPT 6) 0,800 14 7 4631 8) 11,4 475 II2G EEx md IIC T5: 1/2 x 14 NPT 6) 0,800 14 4 4632 8) ) 15,2 66 II2G EEx md IIC T5: M20 x 1,5 6) 0,800 14 7 4633 8) 13,6 567 Div 1 and 2-20... +60 Flying leads 450 mm 0,500 15 1 3726 15,7 68 Div 1 and 2-20... +60 Flying leads 450 mm 0,500 15 5 3727 s and circuit s, see 107
actuators 16C 6,8 284 IP 65-25... +60 DIN EN 175301-803 0,300 10 1 0827 7) 10,6 46 IP 65-25... +60 DIN EN 175301-803 0,350 11 6 3805 7) 10,6 46 II3G EEx na II T4 T4: DIN EN 175301-803 - 11 6 3818 II3D IP 65 T 110-20... +60 Form A, with special screw 8,9 369 II2G EEx me II T5: M20 x 1,5 6) 0,500 13 4 4270 8) T4: T 130 2) -40... +65 10,0 43 II2G EEx me II T5: M20 x 1,5 6) 0,500 13 7 4271 8) T4: T 130 2) -40... +65 8,9 369 II2G EEx md IIC T6: 1/2-14 NPT 6) 0,800 14 4 4670 8) 10,0 43 II2G EEx md IIC T6: 1/2-14 NPT 6) 0,800 14 7 4671 8) 8,9 369 II2G EEx md IIC T6: M20 x 1,5 6) 0,800 14 4 4672 8) 10,0 43 II2G EEx md IIC T6: M20 x 1,5 6) 0,800 14 7 4673 8) 8,9 369 Div 1 and 2-20... +60 Flying leads 450 mm 0,500 15 1 3824 9,5 41 Div 1 and 2-20... +60 Flying leads 450 mm 0,500 15 5 3825 s and circuit s, see 6) Connector/cable gland not supplied, see 'Accessories' table 108
actuators 16D 16,9 703 IP 65-25... +60 DIN EN 175301-803 0,260 10 1 0800 7) 17,3 75 IP 65-25... +60 DIN EN 175301-803 0,350 11 6 3803 7) 16,9 703 II3G EEx na II T4 T4: DIN EN 175301-803 0,270 10 1 3817 II3D IP 65 T 130-20... +60 Form A, with special screw 17,3 75 II3G EEx na II T4 T4: DIN EN 175301-803 0,360 11 6 3819 II3D IP 65 T 120-20... +50 Form A, with special screw 11,4 475 II2G EEx me II T5: M20 x 1,5 6) 0,500 13 4 4280 8) T4: T 130 2) -40... +50 15,2 66 II2G EEx me II T5: M20 x 1,5 6) 0,500 13 7 4281 8) T4: T 130 2) -40... +50 11,4 475 II2G EEx md IIC T5: 1/2 x 14 NPT 6) 0,800 14 4 4680 8) 15,2 66 II2G EEx md IIC T5: 1/2 x 14 NPT 6) 0,800 14 7 4681* 8) 11,4 475 II2G EEx md IIC T5: M20 x 1,5 6) 0,800 14 4 4682 8) T6/T4-40... +50 15,2 66 II2G EEx md IIC T5: M20 x 1,5 6) 0,800 14 7 4683 8) T6/T4-40... +50 13,6 567 Div 1 and 2-20... +60 Flying leads 450 mm 0,500 15 1 3826 15,7 68 Div 1 and 2-20... +60 Flying leads 450 mm 0,500 15 5 3827 s and circuit s, see 6) Connector/cable gland not supplied, see 'Accessories' table 109
1 2 3 1 Connector can be rotated 4 x 90 2 Ø 13 (with spacer tube) 110