Installation/Operating Instructions

Similar documents
Installation/Operating Instructions

1000 DE BOSS. Installation & Operating Instructions COMMERCIAL FIXTURE READ THESE INSTRUCTIONS BEFORE FIRING UP YOUR BALLAST

Installation/Operating Instructions

Technical Information Guide

8 Light Controller. Instruction Manual. With Light Timer 240 Volts. Product # INNOVATING SINCE 1995

Helios. 24 Light 240 Volt Controller. PRODUCT # Instruction Manual.

Instruction Manual. H.I.D Digital Ballasts 400W 600W 1000W. All our ballasts are compatible with Safe Grow Hydroponic Smart System.

315W CMH COMPLETE GROW LIGHT SYSTEM [ V] USER MANUAL

AC POWER SOURCE PURE SINE WAVE DC-AC INVERTERS OWNER S MANUAL

DC-AC Power Inverter SAM Manual. Please read this manual before installing your inverter

gamma uv Aquarium Ultraviolet Sterilizers

GC SERIES HORTICULTURAL LIGHTING SYSTEM

MAINTENANCE SPECIFICATIONS LEGISLATION WARRANTY

Sylvania 9 Color Changing One Plug Tree Tree ID # T5, Item # V

O W N E R ' S M A N U A L

User s Manual. Automatic Switch-Mode Battery Charger

GC SERIES HORTICULTURAL LIGHTING SYSTEM

BT403. A Geno Technology, Inc. (USA) brand name. BT-300 Power Supply. Cat. No. BT

PURE SINE WAVE DC-AC INVERTERS

COMMERCIAL DE LIGHT SYSTEM INSTALLATION AND TECHNICAL MANUAL

USER MANUAL DOUBLE ENDED LIGHTING SYSTEMS (ALL MODELS) OPEN, ENCLOSED AND SUPER DEEP SYSTEMS

Owner's Manual. For latest instructions please go to

Henny Penny Rotisserie Display Model SCD-6/8 TECHNICAL MANUAL

AC / 65 W M PLEASE READ BEFORE OPERATING THIS EQUIPMENT.

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Chef Bases

Owner's Manual. For latest instructions please go to

WARNINGS, CAUTIONS AND NOTES

SpectroLED 9 PRODUCT GUIDE

ASSEMBLY AND INSTALLATION INSTRUCTIONS

WF-5110R True Sine Wave Inverter

SunPro Complete DE Fixture 1000W HPS

SpectroLED 14 PRODUCT GUIDE. Genaray SpectroLED 14 Guide Page 1

Illustrations on the manual are for installation purposes only. It may not be identical to the fixture purchased.

Drip-n-Gro Dual Top Feed Drip System Instruction Manual

Source Capture Air Purification System

PL900 ILLUMINATOR. Fiber-Lite. Operation Manual. Setup. Fiber Optic Connection A PRODUCT OF DOLAN-JENNER INDUSTRIES. Voltage Selection:

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Glass Door Countertop Refrigerator

OPERATING INSTRUCTIONS

FOR INDOOR/SEASONAL USE ONLY

Installation & Operation Manual Chef Base

Item no Smart AC 200 USB. User s Manual

Submersible Pond Pump with UV 800 Gallons Per Hour

SpectroLED 9 PRODUCT GUIDE. Genaray SpectroLED 9 Guide Page 1

Owner's Manual. mycharge name and logo are registered trademarks of RFA Brands RFA Brands. All Rights Reserved. Patent Pending.

contents Advisory... 3 Acoustics... 4 Installation... 5 Remote Control Function... 11

OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

REMOVAL OF FACTORY GAUGE ULTRA FLHT & FLHX (STREET GLIDE

Owner's Manual. For latest instructions please go to

7.5 FT PRE-LIT ENGLEWOOD PINE TREE

Reach ins, Freeezers & Refrigerators Installation & Operation Manual

16 Inch Hanging Pendant Barn Light

7.5' LED Silver Glitter with Pinecones One Plug Tree V INSTRUCTION MANUAL

WF-5100 Series True Sine Wave Inverters

Swing Arm Magnifying Lamp

ROPE LIGHT ITEM # MODEL #UCL48L. Français p. 8. Español p. 15 ATTACH YOUR RECEIPT HERE. Purchase Date

60 Watt Industrial LED Low Bay Light

READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

OWNER S MANUAL PORTABLE POWER COMPACT & ROBUST

Owner's Manual. 120 Watt DC-AC Inverter Pure Sine Wave PST-12S-12A. Please read this manual before using your inverter

Sawhorse with Chainsaw Holder

WF-5110R True Sine Wave Inverter

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

Operator s Manual. Automatic Electric Jack Leveling. The leveling system shall only be operated under the following conditions:

Powerful & Intelligent Submersible Pumps

READ AND SAVE THESE INSTRUCTIONS. ComfortBreeze UV360-1 SYSTEM 24V Ultra-Violet Air Cleaner. Trion

OCTA FLUORESCENT 7 SOCKET FIXTURE

NANOPAC-300 & 500 Power Supply. Instruction manual NANOPAC-300 & NANOPAC-500

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

1000-Watt Energy Center

Use and Care Guide.

Bottom Loading Water Dispenser

MaxLite LED UTILITY WRAP FIXTURES

Operator Manual For use with WFCO ULTRA III Deckmount Converter WF-9800 Series (model number located on the cover of the unit)

steady cool fluorescent IUF-55 INSTRUCTIONS

Automatic Emergency Light

MCL-30K-TCH. Remove nuts/screws and clamp to remove factory gauges 1 MAN#650336

Pure Sine Wave Inverter GP-HS1500. Owner s Manual

c EDR /11. ShipShape OWNERS MANUAL. [ power foundations ]

IN1001/IN1003 ANALOGUE INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL IN1001/IN1003 ANALOGUE INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL

Operating Instructions

1200+ WITH LVD (LOW VOLTAGE DISCONNECT) USER GUIDE

k EDR /11. S cape OWNERS MANUAL. S cape Platform. Silhouette. Pro-motion. Bronze. [ power foundations ]

User s Manual and Operating Instructions

Questions or Concerns? Please contact us Mon - Fri 9:00AM - 6:00PM PST at (888) or Natural Himalayan Salt Lamp

Transfer Switch TS-50. Owner s Manual

Bulbs are not included. FF-OF4 Octa 4 Socket Fluorescent Fixture INSTRUCTIONS

INSTALLATION INSTRUCTIONS

TBX10A INSTALLATION/OWNER'S MANUAL 10" Sealed Enclosure with Built-in Amplifier

User s Manual. ClipperCreek, Inc. Innovative Infrastructure for Electric and Hybrid Vehicles. Model PCS-15

110 Volt/12 Volt Portable Inflator

Have a Bright Day! Nicholas Harmon President, Verilux, Inc.

HLY-1111 HEAD TEMPERATURE GAUGE

Gavita HortiStar 600 SE EU

DC TO AC POWER INVERTER PWRIC150012W INSTRUCTION MANUAL

Owner s Guide. ca5354

PH21/27 POWERHOUSE Dual Generator Parallel Kit Operating Instructions

LED LARGE WALL PACK (CUTOFF & STANDARD)

ESE Series Cast Iron Sewage Pumps

Transcription:

Installation/Operating Instructions LEC 315 COMMERCIAL ETELLIGENT INCLUDES CONVERTIBLE SMART VOLT DUAL FERRITE POWER CORD easily converts into either a 120 or 208/240 volt 6.5 foot power cord ETELLIGENT CONTROLLER compatible Sun System 1 LEC Ballasts are controller-compatible with signal ports for on /off /dimming functions (Etelligent controller sold separately) Product # 902257 Sun System 1 LEC 315 Commercial Etelligent 120V-240V READ THESE INSTRUCTIONS BEFORE FIRING UP YOUR BALLAST KEEP ORIGINAL PACKAGING all returns need to be in the original packaging in order to avoid product damage during shipping. Any damage to products not in their original packaging will not be covered under warranty. SAFETY FIRST! Failure to observe the following safety warnings may result in serious injury. In addition, failure to observe these safety warnings will result in a waiver of all liabilities and will void all warranties. WARNING If the exterior of the lamp is damaged, replace lamp immediately. When re-lamping, make sure lamp has time to cool before touching. Make sure power cord is connected properly. Disconnect power before re-lamping. DO NOT hang by power or lamp cord. DO NOT make contact with the interior of the socket while power is on. DO NOT operate light systems in wet locations. DO NOT plug system into supply voltage other than what is designated on ballast. DO NOT attempt to rewire or reconfigure your system, it will void warranty and could cause serious safety hazards (i.e. power cord, lamp cord, lamp socket or ballast). Keep away from children.

LEC 315 COMMERCIAL SYSTEM SETUP: 1. Remove the system from the box along with all additional parts. 2. These systems do not require much setup. 3. Carefully insert the proper lamp into the socket making sure you line up the pins correctly then gently twist until the lamp locks in. Please refer to lamping installation instructions on back. 4. Hang the fixture using V-hangers provided. 5. Plug the unit into the proper NEMA configured receptacle or hardwire unit depending on model voltage. lamp base Fig. 1 lamp-holder different pins BULB INSTALLATION: Use gloves or cloth to avoid handling lamp with bare hands. The lamp base has pins with different shapes (Fig. 1). Line up the correct pins with the lamp-holder. Carefully press down and turn 30-45 degrees clockwise until lamp locks in. The lamp-holder will give a snap-in sensation to confirm proper insertion of the lamp. NOTE - Until the lamp has achieved at least 10 hours of operation, the lamp should never be turned off sooner than 2 minutes. This Includes during installation tests. In cases when this has happened you need to wait 1 hour before switching the lamp on again.

SAFETY FIRST! DO NOT alter or modify this unit in any way. It may cause bodily injury or death as this is a high power electrical device. DO NOT submerse in water or splash water on the unit. DO NOT plug or unplug the lamp cord while the ballast is energized. These high performance, high frequency electronic ballasts are extremely efficient. They have a high power factor and high luminous efficacy. It s stable performance creates constant power output even when power fluctuates (power surge). Short circuit protection technology prevents damage to the lamp and other ballasts connected to the same circuit. 1. INSTALLATION PROCEDURE DO NOT alter or modify the electronic ballast in any way. Not only may it damage the unit, it will void the warranty. Lamp power rating must match electronic ballast power rating. Connect Sun System lamp cord with male plug to female receptacle on ballast The 902257 Ballast offers our exclusive Convertible Smart Volt 120/240V Power Cord. 2. SPECIFICATIONS 120, 208 or 240 Volt Power source frequency: 50/60Hz Power Factor (cosø): > 0.97 Ambient Temp: 50 F to 120 F Includes Convertible Smart Volt Dual Ferrite Power Cord that easily converts to either 120 or 208/240 volt power. Crest Factor: < 1.6 Acoustic Resonance: none Total Harmonic Distortion: (THD): < 10.0% 3. NOTES This Sun System LEC Commercial Ettelligent Electronic Ballast is designed to operate 315 Watt Ceramic Metal Halide lamps. This unit offers short-circuit and power fluctuation. Features internal built-in circuit breaker. CONNECT APPROPRIATE AC POWER PLUG HERE 240V WIRING - VERY IMPORTANT! All digital ballasts may malfunction if the 240V circuit has a neutral. The input for the ballast is 2 HOT WIRES and 1 GROUND WIRE. If you are using a light controller ONLY bring a ground wire and two hot leads from your electrical panels. HOT RESTRIKE - The Sun System One features a hot restrike function to protect the lamp and ballast. This function allows the ballast to reignite the lamp once it has cooled. In the event of a power interruption or failed ignition the ballast will wait one minute and attempt to restart the lamp. If the lamp does not ignite at that time it will make four more attempts in five minute intervals. If the ballast has ran though the complete sequence (1 minute -5 minutes -5 minutes -5 minutes -5 minutes) the ballast will go into a locked mode. The ballast will not begin the ignition sequence again until it has been disconnected from power. This can be achieved by unplugging the ballast and plugging it back in or waiting until the next set timer cycle. Do not unplug the ballast until it has completed the full twenty-six minute sequence.

LAMP REPLACEMENT - Be sure to disconnect the power source before changing lamps. Always use a 315 watt Ceramic Metal Halide lamp (ANSI C182/0 or C182). TIMER BOX - If you are connecting a 240 V ballast to a timer box, please make sure that it cuts off both legs when timer is switched off. If you continue to supply 120 V to your ballast when the timer is switched off, it may damage your ballast. ERROR CODES - If the ballast encounters any abnormal conditions the built in self-diagnostic feature will display easily identifiable error codes. Error codes can be identified by the number of flashes made by the green LED marked turbo. 1 Flash = Ballast Protection: This code means that the ballast has gone into a locked mode to protect itself. This may be followed by another code to help troubleshoot the cause. 2 Flash = Bad Lamp/Short Circuit: This code means that the ballast has a bad connection somewhere between the ballast and lamp. Reasons can include a bad lamp, loose lamp, loose lamp cord, a short in the cord or reflector, or a short in the ballast receptacle. 3 Flash = Low Voltage: This code means the power coming from the outlet to your ballast is not sufficient to power the unit. 4 Flash = Over Temperature: this code means the ballast has shut itself off due to overheating (>140 F). 5 Flash = Over Voltage: This code means the power from the outlet to your ballast has exceeded the maximum allowed voltage. 6 Flash = Lamp Fault: incorrect/non compatible lamp will not work with ballast. Lamp is EU standard. ETELLIGENT CONTROLLER KIT COMPATIBLE - This ballast is controller-compatible with Sun System 1 Ballast signal ports for wired control of the on/off/ dimming functions. The Sun System 1 Etelligent Controller Kit #902245 (sold separately), allows up to 400 Sun System 1 ballasts to be daisy-chained together.

TROUBLESHOOTING GUIDE Follow the troubleshooting tips below. If troubleshooting techniques fail, bring ballast back to your place of purchase to request warranty service. POSSIBLE CAUSES LAMP LOOSE IN SOCKETS INCORRECT VOLTAGE DEFECTIVE OR IMPROPER WIRING POOR ELECTRICAL CONNECTIONS INCORRECT LAMP LAMP DAMAGE CORRECTIVE MAINTENANCE Make sure that the lamp is fully inserted into the sockets and that the sockets are in the closed position. Make sure you are using the correct input voltage with ballast. If using incorrect voltage, disconnect the ballast from the power source immediately. Examine wiring to ensure it agrees with wiring diagrams on ballast label. Check connections to see that they are secure. If wiring a 240V ballast, DO NOT use a neutral. The correct wiring is two hot wires and a ground. Check wiring and lamp contact with socket. Make sure the lamp cord is firmly seated in output receptacle. Verify that you are using a 315 Watt CDM lamp. Lamps manufactured according to European or Asian specifications will not provide consistent performance. Investigate possibility of outer bulb damage. Look for broken tubes or loose metal parts. Replace lamp. Part 15 compliance Advisory statement The interference potential of the device or system Maintenance of the system Simple measures that can be taken by the user to correct interference This device complies with Part 18 of the FCC Rules. This product may cause interference to radio equipment and should not be installed near maritime safety communications equipment or other critical navigation or communication equipment operating between 0.45-30 MHz. The interference potential of the device or system is the operating frequency; 110 khz. Unplug the unit, wait 30 seconds, and plug the unit back in. Move the unit away from any radio device. This product contains delicate electronic components. This means that if it is placed near an object that transmits radio signals, it could cause interference. This could be, for example, mobile telephones, walkie talkies, CB radios, remote controls and microwaves. If interference occurs, move such objects away from the appliance. Sun System One LEC 315 Watt 120-240 Volt. Compliant with FCC Part 18 Class A (governs commercial use) and FCC Part 18 Class B (governs residential use) as tested by an independent US testing lab in a true as used configuration. In our case, Northwest EMC or ElectroMagnetic Investigations, Hillsboro OR. This installation guide does not supersede national, state, or local regulations for electrical installations.

TROUBLESHOOTING IF YOUR FIXTURE DOES NOT WORK: 1. CHECK YOUR ELECTRICAL SOURCE: Make sure the unit is plugged in properly and that the breaker is not tripped or fuse blown. 2. CHECK THE LAMP: Make sure the lamp is fully seated in the socket. WARRANTY SERVICE: Please read warranty information firstif after troubleshooting problems the light will still not work, you should return the light to the dealer where you purchased it. They will be able to further evaluate the light and test its various components and quite possibly will be able to identify and/or fix any problems. Often the problem is as simple as a defective lamp. If the dealer is unable to fix the light, they will return it to us for factory repair. Many dealers have loaner fixtures that you may check out until yours is returned (usually not more than 7-10 days).to locate the dealer nearest you, visit our website at www.sunlightsupply.com and complete the Dealer Search. If there are no dealers in your area, you may contact us directly for technical support. If we cannot help you resolve the problem over the phone, we will issue you a RMA # (return merchandise authorization) authorizing you to return the system to us for factory reconditioning (if the unit is under warranty). You will need to provide an email address or fax number so that the Authorization Form may be sent to you. You will need to include this Authorization Form in the packaging when returning your Sun System unit. Also please write the # on the outside of the box.please package the light carefully in its original packaging. If it is damaged in shipment we will not be responsible. Once we receive the light back, we will repair it within 48 hours (business) and return it to you via UPS Ground. If the unit cannot be repaired, a replacement will be sent. If there are no replacements available, a comparable unit will be sent back. IMPORTANT: PROOF OF PURCHASE REQUIRED FOR RETURNS SUN SYSTEM LEC 315 COMMERCIAL FIXTURE = 3 Year WarrantyReturning Units: Please contact your retail store for returns.warranty INFORMATION: Sunlight Supply, Inc. warrants to the original purchaser of this product against defects in material and workmanship under normal use for 1 year on Sun System LEC 315 Commercial fixture. During the warranty period, Sunlight Supply, Inc. will, at our option, and without charge, repair or replace this product if the unit or any of its components fail or malfunction. This warranty is expressly in lieu of all other warranties, expressed or implied, including the warranties of merchantability and fitness for use and of all other obligations or liabilities on the part of the seller. This warranty shall not apply to this product or any part thereof which has been damaged by accident, abuse, misuse, modification, negligence, alteration or misapplication. Sunlight Supply, Inc. makes no warranty whatsoever in respect to accessories or parts not supplied by Sunlight Supply, Inc. This warranty shall apply only to the United States, including Alaska, Hawaii and territories of the United States. NOTE: Sunlight Supply, Inc. is a manufacturer of supplementary lighting systems. All sales offerings to the public are done through a nationwide group of dealers. No sales offerings will be made directly to the general public.

NOTES

NOTES www.sunlightsupply.com 2017 Sunlight Supply, Inc. Vancouver, WA 98660 10/23/2017SD