WARNING! READ BEFORE INSTALLATION

Similar documents
m WARNING! READ m BEFORE INSTALLATION

Product Specification A1000i Loop Powered/4-20mA Submersible Level Transmitter/Transducer

Product Specification A1000i Loop Powered/4-20mA Submersible Level Transmitter/Transducer

Installation, Operation and Maintenance Instructions Output Range Part Number Input psi bar Impedance Output Range

EG Series Installation Manual

LIMIT SWITCH Hawkeye - HX Magnetic Solid State Proximity Sensors Installation, Maintenance and Operating Instructions (HX )

PXT-K Series. Pressure Transmitters Section 05

FAIRCHILD T8001 SERIES STANDARD RANGE MINIATURE TWO-WIRE, P/I PRESSURE TRANSDUCER. Installation, Operation and Maintenance Instructions

Miniature I/P, E/P Transducer

Installation Manual OPEN. For Corrosive Service. The ONYX integrates electronic sensors and pneumatic valving into a vapor tight enclosure.

FAIRCHILD T5200 SERIES ELECTRO-PNEUMATIC TRANSDUCER Installation, Operation and Maintenance Instructions

Miniature I/P, E/P Transducer for Electronic Air Pressure Control

Fisher i2p 100 Electro Pneumatic Transducer

Miniature I/P, E/P Transducer for Electronic Air Pressure Control

V200 Series Positioners

MODEL K WIRE INDICATING PRESSURE TRANSMITTER INTRINSICALLY SAFE VERSION OPERATION AND INSTRUCTION MANUAL

% # ) Intrinsically Safe & Non-Incendive Field Wiring Valves Aluminum, Brass, or Stainless Steel Bodies 1/4" to 1" NPT

Fisher 546 Electro Pneumatic Transducer

Type 500X. Electropneumatic Transducer (I/P, E/P) Installation, Operation and Maintenance Instructions. Ordering Information.

LTX RF LEVEL SENSOR. Instruction Manual

Type Installation, Operation and Maintenance Instructions. Ordering Information. Contents CA20 -

Features. Flexibility

Type Type 1001 Transducers. I/P & E/P Transducers

Ex Instruction manual. Rotamass Coriolis mass flow meter. IM 01U10X03-00EN-R, 1st edition, Rev FM-1

Low Power. 1.4 W Low Power Solenoid Valves. Brass or Stainless Steel Bodies 1/4" to 1" NPT. Features

Maximum Line Resistance vs. Length of Wire Max. Loop Resistance. Max. Wire Run 18AWG 7x26 Stranded (ft)

Kimray reserves the right to modify or improve the designs or specifications of such products at any time without prior notice Kimray Inc.

P200 P/I Transducer. Installation, Operation, and Maintenance Instructions INTRODUCTION

Rosemount Product Data Sheet , Rev GA Catalog FIELDBUS PROTOCOL. Hazardous Locations Certifications

EZ-LIGHT K30L and K50L Intrinsically Safe Indicators

The T5220 Series Electro-Pneumatic Transducer converts a DC current or voltage input signal to a directly proportional pneumatic output.

METAL VAREA-METER STRAIGHT THROUGH TYPE ROTAMETER

Certificate of Compliance

Fisher 646 Electro Pneumatic Transducer

Fisher 646 Electro Pneumatic Transducer

NIFW % # ) Air and Inert Gas Non-Incendive Field Wiring Valves 2/2 3/2 4/2 5/2 5/3 SERIES. Brass, Aluminum, or Stainless Steel Bodies 1/4" to 1" NPT

Figure 1: WPR2 Dimensions and Hardware

534HS Pressure Transmitter

TripMate User Guide. Magnetic Shut-Off Switch. Plunger Arrival Sensor

Mid-West Instrument. Series 700 "Wet/Wet" Installation and Operating Instructions. Differential Pressure Transmitter

AST44LP Intrinsically Safe Low Pressure Transducers / Transmitters

AUTOMATION. Operator s Manual. RPM Series Float Level Sensors. Rev. E, 08/16 Doc Automation Products Group, Inc.

% # ) Air and Inert Gas Intrinsically Safe Valves 2/2 3/2 4/2 5/2 5/3 SERIES. Brass, Aluminum, or Stainless Steel Bodies 1/4" to 1" NPT

T-1001 TYPE 1001 I/P & E/P TRANSDUCERS

InVue Electronic Flowmeter, Model NT4400

Type 80 Wafer and Type 81 Bolt-Thru Isolation Rings. Installation, Maintenance and Safety Instructions

Type 2000 Transducer Product Instructions

Fisher 3660 and 3661 Positioners

Series Level-Trol Electronic Liquid Level Transmitters

Optic Level Switch LO10 Series Owner s Manual

SATRON VT Pressure Transmitter

I/P CONVERTER INSTRUCTION MANUAL (E)IM-TE100/00-R5

Metal Particle Detector

PIT, PIF & PIX Pressure-to-Current Transmitters

Intrinsically safe presure transmitters for hazardous environments Type MBS 4201, MBS 4251, MBS 4701 and MBS Technical brochure

Type Type I/P & E/P Transducers

Electropneumatic Transducer (I/P, E/P)

L E V E L P L U S M - S E R I E S ANALOG

Fisher 3610J and 3620J Positioners and 3622 Electro Pneumatic Converter

1100 Series Piston Type Differential Pressure Gauges

Low Flow Transmitter EJX115A and EJA115E

SPANS AND RANGES. Lower Range Limits 150 in. H 2 O ( 38 kpa) 800 in. H 2 O ( 200 kpa)

AMETEK MODEL 88 SERIES ELECTRONIC PRESSURE TRANSMITTER

Valve model number description

PIT, PIF & PIX. Features. Pressure-to-Current Transmitters

SETRA Operating Instructions Series DPT 230 Pressure Transducers

Rosemount 3051CFA Annubar Flowmeter

Type E-10, E-11 Hazardous Area Explosion-proof Transmitters

Certificate of Compliance

PRESSURE BENCH OPERATING INSTRUCTIONS

Fisher 3710 and 3720 Positioners and 3722 Electro Pneumatic Converter

SATRON VDt Differential Pressure Transmitter

Certificate of Compliance

Type I/P & E/P Transducers

Ultrasonic Two-Wire Point Level Control

FAIRCHILD T5220 SERIES ELECTRO-PNEUMATIC TRANSDUCER Installation, Operation and Maintenance Instructions

Smart Pressure Transmitter

Model 8800C Vortex Flowmeter

ABB Instrumentation. 50T Series Transmitters Model 54G/A gauge/absolute pressure transmitter for sanitary use. Specification sheet

PT-500 Analog Output Series User Manual

Fisher i2p-100 Electro Pneumatic Transducer

199.9 µa to A *, mv (AC or DC) * Accessory Shunts Available For Higher Current Ranges.

ABB MEASUREMENT & ANALYTICS DATA SHEET. AV1 and AV2 Characterizable pneumatic and electro-pneumatic positioners

BTE2000 / PTE2000 Series Precision stainless steel pressure transmitters

Fisher 3582 and 3582i Positioners, 582i Electro-Pneumatic Converter, and 3583 Valve Stem Position Transmitters

Fisher 3582 and 3582i Positioners, 582i Electro Pneumatic Converter, and 3583 Valve Stem Position Transmitter

Fisher 646 Electro Pneumatic Transducer

Maximum 20 ma, 24 VDC 825 ohms (see section 3.3) Supply voltage dependence

User s Manual Model EJA110A, EJA120A and EJA130A Differential Pressure Transmitters

Fisher FIELDVUE DVC6000f Digital Valve

PEAKTRONICS DMC-101 ADDITIONAL FEATURES. DC Motor Controller, 5A DMC-101

TECHNICAL BULLETIN. Logix 510si Series Digital Positioner. Experience In Motion FCD LGENTB /09

Valve Positioners Series 760P/E Valve Positioners

Rosemount 3300HT/3300HTVP/3400HT/ 3400HTVP/3500P/3500VP

Instructions-Installation 3A4409C EN. See page 3 for model part numbers and approvals information.

TEK-B AR 3110A. Differential Pressure Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys PRESSURE

I/A Series Intelligent Differential Pressure Transmitters

Mobrey MLT100. Displacer Level Transmitter. Product Data Sheet February 2015 IP119, Rev CA. Level, contents or interface measurement transmitter

REMOTE MOUNT SOLENOID DRIVER (0-5 VDC/0-20 ma/10k Potentiometer Input)

Fisher 3610J and 3620J Positioners and 3622 Electro Pneumatic Converter

Transcription:

A4 INTRINSICALLY SAFE & NON-INCENDIVE RATED PRESSURE TRANSMITTER INSTRUCTION SHEET WARNING! READ BEFORE INSTALLATION 1. GENERAL: A failure resulting in injury or damage may be caused by excessive overpressure, excessive vibration or pressure pulsation, excessive instrument temperature, corrosion of the pressure containing parts, or other misuse. Consult Ashcroft Inc., Stratford, Connecticut, USA before installing if there are any questions or concerns. 2. OVERPRESSURE: Pressure spikes in excess of the rated overpressure capability of the transducer may cause irreversible electrical and/or mechanical damage to the pressure measuring and containing elements. Fluid hammer and surges can destroy any pressure transducer and must always be avoided. A pressure snubber should be installed to eliminate the damaging hammer effects. Fluid hammer occurs when a liquid flow is suddenly stopped, as with quick closing solenoid valves. Surges occur when flow is suddenly begun, as when a pump is turned on at full power or a valve is quickly opened. Liquid surges are particularly damaging to pressure transducers if the pipe is originally empty. To avoid damaging surges, fluid lines should remain full (if possible), pumps should be brought up to power slowly, and valves opened slowly. To avoid damage from both fluid hammer and surges, a surge chamber should be installed. Symptoms of fluid hammer and surge's damaging effects: Pressure transducer exhibits an output at zero pressure (large zero offset). Pressure transducer output remains constant regardless of pressure In severe cases, there will be no output. FREEZING: Prohibit freezing of media in pressure port. Unit should be drained (mount in vertical position with electrical termination upward) to prevent possible overpressure damage from frozen media. 3. STATIC ELECTRICAL CHARGES: Any electrical device may be susceptible to damage when exposed to static electrical charges. To avoid damage to the transducer observe the following: Operator/installer should follow the proper ESD (electrostatic discharge) protection procedures before handling the pressure transducer. Ground the body of the transducer BEFORE making any electrical connections When disconnecting, remove the ground LAST! Note: The shield and drain wire in the cable (if supplied) is not connected to the transducer body, and is not a suitable ground. 4. HAZARDOUS AREA SPECIFIC GUIDELINES 1. Do not open unit when energized. 2. Do not diconnect equipment unless area is known to be non-hazardous. Ashcroft A4 Pressure Transmitter, Typical Dimensions and Construction* Enclosure Option S Enclosure Option W.50 Cable style electrical termination.887 (22.5).887 (22.5) Conduit style electrical termination 4.45 3.065 1.06 DIA. 4.78 (121) 3.065 (78) 1.06 (27) DIA. 4.78 (121) 3.065 (78) 1.06 (27) DIA..885 1.06 Hex. Common For All Pressure Fittings Threaded Male Process Connection.675 (17).885 (22) 1.06 (27) Hex. Common For All Pressure Fittings *Dimensions and construction details may vary based on product specified. 2016 Ashcroft Inc. All rights reserved. 250 East Main Street, Stratford, CT 06614 USA Tel: 203-378-8281, Fax: 203-385-0402 www.ashcroft.com

INSTALLATION NOTES Voc OR Vt 30VDC Isc OR It 100mA Ca 0.053uF Ccable La 0.364uH Lcable 1. THE INTRINSIC SAFETY ENTITY CONCEPT ALLOWS THE INTER- CONNECTION OF TWO INTRINSICALLY SAFE DEVICES FM APPROVED WITH ENTITY PARAMETERS NOT SPECIFICALLY EXAMINED IN COMBINATION AS A SYSTEM WHEN: Uo OR Voc OR V t Vmax, Io OR Isc OR It Imax, Ca OR Co Ci Ccable, La OR Lo Li Lcable, Po Pi. 2. THE NONINCENDIVE FIELD WIRING CONCEPT ALLOWS INTER- CONNECTION OF NONINCENDING FIELD WIRING APPARATUS WITH ASSOCIATED NONINCENDIVE FIELD APPARATUS USING ANY OF THE WIRING METHODS PERMITTED FOR NON3HAZ- ARDOUS (UNCLASSIFIED) LOCATIONS WHEN: Uo OR Voc OR Vt Vmax, Io OR Isc OR It Imax, Ca OR Co Ccable, La OR Lo Li Lcable, Po Pi. 3. FOR DIVISION 1 INSTALLATIONS, THE CONFIGURATION OF ASSOCIATED APPARATUS SHALL BE FM APPROVED UNDER ENTITY CONCEPT. 4. FOR DIVISION 2 INSTALLATIONS USING NONINCENDIVE FIELD WIRING CONCEPTS THE ASSOCIATED APPARATUS SHALL BE FM APPROVED UNDER THE ENTITY CONCEPT OR NONINCENDIVE FIELD WIRING CONCEPT. 4.3 FM INSTALLATION GUIDELINES INSTALLATION FOR FM INTRINSICALLY SAFE CLASS 1, GROUPS A, B, C & D & CLASS ll, GROUPS E, F & G & CLASS lll 5. FOR DIVISION 2 INSTALLATIONS THE ASSOCIATED APPARATUS IS NOT REQUIRED TO BE FM APPROVED UNDER ENTITY CON- CEPT OR NONINCENDIVE FIELD WIRING CONCEPT IF THE A2X(4-20mA) & A4 SERIES PRESSURE TRANSDUCER IS INSTALLED IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE (ANSI/NFPA 70) FOR DIVISION 2 WIRING METHODS EXCLUDING NONINCENDIVE FIELD WIRING. 6. CONTROL EQUIPMENT CONNECTED TO THE ASSOCIATED APPA- RATUS SHALL NOT USE OR GENERATE MORE THAN 250VRMS OR VDC. 7. DIVISION 1 INSTALLATIONS SHOULD BE IN ACCORDANCE WITH ANSI/ISA RP12.06.01, ``INSTALLATION OF INTRINSICALLY SAFE SYSTEMS FOR HAZARDOUS (CLASSIFIED) LOCATIONS'' AND THE NATIONAL ELECTRICAL CODE (ANSI/NFPA 70). 8. ASSOCIATED APPARATUS MANUFACTURERS INSTALLATION DRAWING SHALL BE FOLLOWED WHEN INSTALLING THIS EQUIPMENT. 9. RUN SHIELDED INTERCONNECTION CABLE WITH SHIELD CON- NECTED TO FM APPROVED ASSOCIATED APPARATUS GROUND. 10. WARNING DO NOT OPEN WHEN ENERGIZED. 11. WARNING DO NOT DISCONNECT EQUIPMENT UNLESS AREA IS KNOWN TO BE NON-HAZARDOUS. HAZARDOUS (CLASSIFIED) AREA CLASS I, DIVISION 1 & 2, GROUPS A, B, C, & D; CLASS II, DIVISION 1 & 2, GROUPS E, F & G, CLASS III NON-HAZARDOUS (UNCLASSIFIED) AREA 24 VDC (1-5 V ) 24 VDC (1-5 V ) 2016 Ashcroft Inc. All rights reserved. 250 East Main Street, Stratford, CT 06614 USA Tel: 203-378-8281, Fax: 203-385-0402 www.ashcroft.com

4.4 CSA INSTALLATION GUIDELINES INSTALLATION FOR CSA INTRINSICALLY SAFE CLASS 1, GROUPS A, B, C & D & CLASS ll, GROUPS E, F & G & CLASS lli INSTALLATION NOTES: Vmax 30VDC Imax 100mA Ci = 0.053uF Li = 0.364uH 1. THE INTRINSIC SAFETY ENTITY CONCEPT ALLOWS THE INTER- CONNECTION OF TWO INTRINSICALLY SAFE DEVICES CSA CER- TIFIED WITH ENTITY PARAMETERS NOT SPECIFICALLY EXAM- INED IN COMBINATION AS A SYSTEM WHEN: Uo OR Voc Vmax, Io OR Isc Imax, Ca OR Co Ci Ccable, La OR Lo Li Lcable, Po Pi. 2. THE NONINCENDIVE FIELD WIRING CONCEPT ALLOWS INTER- CONNECTION OF NONINCENDING FIELD WIRING APPARATUS WITH ASSOCIATED NONINCENDIVE FIELD APPARATUS USING ANY OF THE WIRING METHODS PERMITTED FOR NON3HAZ- ARDOUS (UNCLASSIFIED) LOCATIONS WHEN: Uo OR Voc Vmax, Io OR Isc Imax, Ca OR Co Ccable, La OR Lo Li Lcable, Po Pi. 3. FOR DIVISION 1 INSTALLATIONS, THE CONFIGURATION OF ASSOCIATED APPARATUS SHALL BE CSA CERTIFIED UNDER ENTITY CONCEPT. 4. FOR DIVISION 2 INSTALLATIONS USING NONINCENDIVE FIELD WIRING CONCEPTS THE ASSOCIATED APPARATUS SHALL BE CSA CERTIFIED UNDER THE ENTITY CONCEPT OR NONINCEN- DIVE FIELD WIRING CONCEPT. 5. FOR DIVISION 2 INSTALLATIONS THE ASSOCIATED APPARATUS IS NOT REQUIRED TO BE CSA CERTIFIED UNDER ENTITY CON- CEPT OR NONINCENDIVE FIELD WIRING CONCEPT IF THEA2X (4-20mA) & A4 SERIES PRESSURE TRANSDUCER IS INSTALLED IN ACCORDANCE WITH THE CANADIAN ELECTRICAL CODE (CEC, CAN/CSA3C22.1) FOR DIVISION 2 WIRING METHODS EXCLUD- ING NONINCENDIVE FIELD WIRING. 6. CONTROL EQUIPMENT CONNECTED TO THE ASSOCIATED APPA- RATUS SHALL NOT USE OR GENERATE MORE THAN 250VRMS OR VDC. 7. ASSOCIATED APPARATUS MANUFACTURERS INSTALLATION DRAWING SHALL BE FOLLOWED WHEN INSTALLING THIS EQUIPMENT. 8. RUN SHIELDED INTERCONNECTION CABLE WITH SHIELD CON- NECTED TO FM APPROVED ASSOCIATED APPARATUS GROUND. 9. WARNING SUBSTITUTION OF COMPONENETS MAY IMPAIR INTRINSIC SAFETY 10. WARNING TO PREVENT IGNITION OF FLAMMABLE OR COM- BUSTIBLE ATMOSPHERES, DISCONNECT POWER BEFORE SERVICING. HAZARDOUS (CLASSIFIED) AREA CLASS I, DIVISION 1 & 2, GROUPS A, B, C, & D; CLASS II, DIVISION 1 & 2, GROUPS E, F & G, CLASS III NON-HAZARDOUS (UNCLASSIFIED) AREA 24 VDC (1-5 V ) 24 VDC (1-5 V ) 2011 Ashcroft Inc. All rights reserved. 250 East Main Street, Stratford, CT 06614 USA Tel: 203-378-8281, Fax: 203-385-0402 www.ashcroft.com

A4 INTRINSICALLY SAFE & NON-INCENDIVE RATED PRESSURE TRANSMITTER INSTRUCTION SHEET Mounting The A4 transmitter requires no special mounting hardware, and can be mounted in any plane with negligible position error. Although the unit can withstand normal vibration without damage or significant output effects, it is always good practice to mount the transducer where there is minimum vibration. For units with NPT type pressure fittings apply Teflon tape or an equivalent sealant to the threads before installing. When tightening, apply a wrench to the hex wrench flats located just above the pressure fitting. DO NOT tighten by using a pipe wrench on the housing. Power Supply Power Supply Voltage Output Signal Min Max 4-20mA* 12V** 30V * Refer to Ashcroft drawing #825A022 for supply voltage and load limit. ** The minimum voltage at the terminals is 12Vdc. However, the minimum supply voltage should be calculated using the following graph and formula. Loop Resistance (Ohms) 1000 Loop Supply Voltage vs. Loop Resistance 800 600 400 200 0 10 30 Vdc max for Intrinsically Safe Installations Operating Region 20 30 Loop Supply Voltage (Vdc) Vmin = 12 (.022A x RL) (includes a 10% safety factor) RL = RS RW RL = Loop Resistance (ohms) RS = Sense Resistance (ohms) RW = Wire Resistance (ohms) Noise For minimum noise susceptibility, avoid running the transducer s cable in a conduit that contains high current AC power cables. Where possible avoid running the cable near inductive equipment. Shielded Cable Units with shielded cable electrical termination, connect the drain wire to the guard terminal on the read out device or measuring instrument, if available. In all other cases connect to the ground or to the power supply negative terminal. Vent Tube (Cable Termination Only) The cable has a clear Teflon vent tube required at pressure ranges below 500 psi to provide atmospheric reference. The open end should be placed in a dry area. A4 Wiring Diagrams POWER SUPPLY METER OR OTHER DEVICE PIN 1 PIN 2 () () 4-20mA TRANSDUCER A4 transducer has internal transient protection: for safety, limit line-toground voltage to 36 Vdc max. Zero and Span Adjustment Instructions below apply to the particular configurations noted. While Zero adjustment is not normally necessary, it may be desirable to trim out any offset in the system. However, proper Span calibration requires a pressure standard three to five times more accurate than the accuracy of the transducer, and there may also be interaction of Span on Zero. A4 configurations with enclosure S offer Zero and Span potentiometer access. Access to Z and S pots via the top (electrical termination end) of the unit is standard on all S enclosure units with 4-20mA output. Access is gained by removing the black threaded cap, once removed you will see the pots indicated by Z and S respectively as shown below. Using a small trim pot tool, you can adjust zero ±10% of full scale and span ±10% of full scale..062 Z S Z S Z and S pots Recalibration Instructions: 1. Apply 0% full scale pressure. 2. Adjust the output using the zero adjust trim pot. 3. Apply 100% full scale pressure. 4. Adjust the output using the span adjustment trim pot. 5. Repeat steps 1 through 4 as necessary. HAZARDOUS AREA CERTIFICATIONS Intrinsically Safe (applies to 4-20mA) FM/CSA: Intrinsic Safety: Class I, II and III Div.1 and 2, Groups A, B, C, D, F and G per entity requirements see Ashcroft drawing # 825A022 Non-Incendive: Class I, II and III Div. 2, Groups A, B, C, D, F and G, no barriers needed 2011 Ashcroft Inc. All rights reserved. 250 East Main Street, Stratford, CT 06614 USA Tel: 203-378-8281, Fax: 203-385-0402 www.ashcroft.com

A4 INTRINSICALLY SAFE & NON-INCENDIVE RATED PRESSURE TRANSMITTER INSTRUCTION SHEET Pin # Voltage Current Output Output A () Power () Power B () Output None C Field Gnd. Field Gnd. D (-) Power (-) Power Wire Voltage Current Color Output Output Red () Power () Power White () Output None Black (-) Power (-) Power Green Field Grd. Field Grd. Bare Drain Wire Drain Wire C B 1.062 PROCESS FITTING (REF.) 1.000 1.062 D A.600.830 (4) PIN BENDIX STYLE SHELL SIZE 8 (B4), (H1), (L1), (P2) PIGTAIL CONDUIT - 1/2 NPT MALE (C1), (P7) S FOR WELDED HOUSINGS ONLY Pin Voltage Current Mating No. Output Output Cable Color 1 () Power () Power Red 2 () Output None White 3 Field Gnd. Field Gnd. Green 4 (-) Power (-) Power Black Pin Voltage Current Mating No. Output Output Cable Color 1 () Power () Power Red 2 (-) Power (-) Power Black 3 () Output None White GND Field Gnd. Field Gnd. Green Pin Voltage Current Mating No. Output Output Cable Color A () Power () Power Red B () Output None White C Field Gnd. Field Gnd. Geen D (-) Power (-) Power Black Wire Voltage Current Color Output Output Red () Power () Power White () Output None Black (-) Power (-) Power Green Field Gnd. Field Gnd. Bare Drain Wire Drain Wire 3 2 Key 3 Gnd. 1 C B 4 1 2 D A.71.18.64.65.50 M12 (EW), (E0), (E1), (E2) DIN 43650-A (CD), (DN), (D0), (D1), (D2) (4) PIN BENDIX STYLE SHELL SIZE 8 (B4), (H1), (L1), (P2) PIGTAIL PLASTIC MOLDED (F2), (P1) 2011 Ashcroft Inc. All rights reserved. 250 East Main Street, Stratford, CT 06614 USA Tel: 203-378-8281, Fax: 203-385-0402 www.ashcroft.com

2011 Ashcroft Inc. All rights reserved. 250 East Main Street, Stratford, CT 06614 USA Tel: 203-378-8281, Fax: 203-385-0402 www.ashcroft.com Ashcroft Inc. 250 East Main Street Stratford, CT 06614-5145 USA Tel: 203-378-8281 Fax: 203-385-0402 email: info@ashcroft.com www.ashcroft.com