Model VCD-40. Extruded Airfoil Blade Control Damper Narrowline Frame Construction. Application. Ratings. Flange Options.

Similar documents
Model VCD-43 Extruded Airfoil Blade Control Damper

FBV-43. Vertical Face & Bypass Control Damper Ultra Low Leakage Aluminum Frame Construction. Application and Design. Size Limitations.

VCD-43V. Vertical Airfoil Blade Control Damper. Application and Design. Ratings. Size Limitations. Features and Options: Pressure:

Model VCD-34. Low Leakage Insulated Airfoil CONTROL DAMPER. Ratings (See page 3 for specific limitations) Flange Options.

Model VCD-20. Control Damper. Application. 3V Blade. Ratings. Flange Options. Size Limitations. Blade Operation. Features and Options

Model SEVCD-33. Low Leakage Airfoil Control Damper. Application and Design. Ratings (See page 3 for specific limitations) Blade Operation

VCD-23. Low Leakage CONTROL DAMPER

Model VCD-20V. 3V Vertical Control Damper. Application and Design. Ratings (See page 4 for specific limitations) Flange Options.

Baked Enamel, Epoxy, Hi Pro Polyester, Industrial Epoxy, Kynar/Hylar (70%) Permatector. Single or Reverse Flange 8 x 6 (203 x 178)

Model VCD-33. Low Leakage Airfoil CONTROL DAMPER. Flange Options. Blade Operation. Size Limitations

Model VCD-20 3V CONTROL DAMPER

VCD-23 Low Leakage CONTROL DAMPER

VCD-23. Flange Options. Size Limitations

Thermal Isolation Break. Frame Type Channel Quick Connect Single or Reverse Flange Blade Action Parallel Opposed Parallel Opposed Parallel Opposed

Model VCD-18. Ratings. Blade Operation. Size Limitations. Features & Options

Insulated Control Damper. 12 x 7 (305 x 178) 8 x 7 (203 x 178)

Thermal Isolation. Break

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x 305) 5 in. (127mm) Parallel

AMD-33. Air Measuring Station with VCD-33 Control Damper. Application and Design. Features & Control Options

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x in. W x 120 in. H (3658mm x 3048mm) 5 in.

AMD-33 Air Measuring Station with VCD-33 Control Damper

AMD-42V Air Measuring Station with VCD-42V Control Damper

AMD-42 Air Measuring Station with VCD-42 Control Damper

Model FSD-211. Application. Combination Fire Smoke Damper Steel 3V Blades UL 555S Leakage Class I UL /2 Hour Fire Resistance Rating.

AMD-42-TD. Thermal Dispersion Air Measuring Station with VCD-42 Control Damper. Application and Design. Ratings. Features and Control Options

AMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application. Ratings. Features and Options

Model SMD-301. Smoke Damper Steel Airfoil Blades UL 555S Leakage Class I. Application. Ratings. Size Limitations. Features

Model FSD-331. Combination Fire Smoke Dampers. Application. Ratings. Features

SMD-201. Application. Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

Model SSFSD-211. Combination Fire Smoke Damper 304 Stainless Steel 3V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

Model SMD-302M. Modulating Smoke Damper. Application. Steel Airfoil Blades UL 555S Leakage Class II. Ratings. Size Limitations.

Model FSD-212. Combination FIRE SMOKE DAMPERS

Model FSD-331 Combination Fire Smoke Dampers

SMD-201M. Application. Modulating Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

Model DFD-230 Multi-Blade Fire Damper Steel 3V Blades UL555 3 Hour Fire Resistance Rating

Model FSD-211. Combination FIRE SMOKE DAMPERS Steel 3-V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

Model CFSD-211. Corridor Ceiling FIRE SMOKE DAMPER Steel 3V Blades UL 555S Leakage Class I

HCD-135. Industrial Control Damper. Application and Design. Ratings (see page 2 and 3 for specific limitations) Standard Construction.

HCD-230 Industrial Control Damper

TED50XT EXTREME TEMPERATURE THERMALLY EFFICIENT, INSULATED BLADE DAMPER

HVAC Control & Balancing Dampers

WD-200 Series. Model WD-220 Flange Opposite Motor. Model WD-210 Flange on Motor Side. Model WD-200 No Flange. Motorized Backdraft Damper.

HVAC Control & Balancing Dampers

WD-300 Series. Backdraft Damper Vertical Mount - Horizontal Airflow. Application and Design. Ratings. Frame Styles. Size Limitations.

5995 Greenwood Plaza Blvd. Suite 100 Greenwood Village, CO (fax)

Air Measuring Products. AMS Thermal Dispersion Pressure Differential

Air Measuring Products AMD AMS IAQ

SP Standard Profile. In Duct or Flanged to Duct Install Types OPPOSED ACTION PARALLEL ACTION. Extended Rear Flange Install Type

HVAC Control Damper Models VCD and MBD. Selection Construction Performance

Positive Seal Damper Blades with Vinyl Gaskets 2.5" SERIES 3000 SIDE MOUNT - NO FLANGE ORDERING METHOD FOR BACKDRAFT & MOTORIZED BACKDRAFT DAMPERS

CONTROL DAMPERS. Model Model 1370CB. Model 1380CB. Model 1390CB B7

SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS

ID-141x 12-Gauge Hat Channel Industrial Damper

Control Dampers and Fire Dampers. Volume 1 - March Insulated Control Dampers. Non-Insulated Control Dampers. Framing. Accessories.

LOW LEAKAGE VOLUME CONTROL DAMPER

Control Dampers. Leakage Performance. Model FDNB (Opposed Blade) FDQB (Parallel Blade) Galvanized 3V Blade Control Dampers

Series HCD Airfoil Control Damper

CONTROL DAMPERS. Models 1810 & Model Model Model 1370

FSD60, FSD60LP CoMBINAtIoN FIRe AND SMoKe DAMPeR

SafidDampers SPK Description. Standard Construction SPK ( Flange Type )

ARROW INDUSTRIAL PRODUCTS

Dimensional Data Curb Optional Glass Damper Hood. A B C Size (O.D.) Size (O.D.) Qty Size Actuator Qty

DAMPERS FOR COMMERCIAL & INDUSTRIAL APPLICATIONS IN HEATING, VENTILATING & AIR CONDITIONING

FSD36, FSD36LP COMBINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 2

Motorized Fire Dampers

Model DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features

AMCA MEMBER. American Warming and Ventilating. A Mestek Company. Quality Air Control Dampers

BD-1600 Balancing/Zone Control Damper

SafidDampers SPK Standard Construction SPK Description SPK ( Flange Type )

AFL-501. Aluminum FEMA 361 Louver Chevron Blade Application and Design

Model DFD-150. Dynamic Rated Fire Damper 11/2 Hour Fire Resistance Rating. Application. Ratings. Optional Features

DAMPERS WE CONTROL AIR

L O U V E R S & D A M P E R S

SECTION CONTROL DAMPERS

Model DFD-350. Dynamic Rated Fire Damper 3 Hour Fire Resistance Rating. Application. Ratings. Optional Features

CONTROL & BACKDRAFT DAMPERS. Nailor. Industries Inc.

PC-125x Counter-Balanced Backdraft Damper

ARROW UNITED INDUSTRIES

STATIONARY LOUVERS STATIONARY LOUVERS STATIONARY LOUVERS

A. Product Data: For each type of product. TLC ENGINEERING FOR ARCHITECTURE - PROJECT NO AIR DUCT ACCESSORIES

AD-1250 Airflow Measuring Station

FSD60, FSD60LP COMBINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 1

VD-1600 Series Volume Control Dampers

SD-1250 and SD-1600 Series Smoke Dampers

Introduction to Johnson Controls Dampers

CONTROL DAMPERS GENERAL PRODUCT OVERVIEW MODELS 1010 & 1020 LOW LEAKAGE CONTROL DAMPER VEE GROOVE BLADE MODELS 1012 & 1022 STANDARD CONTROL DAMPER

Installation, Operation, and Maintenance Instructions

Blast Protection Damper

VOLUME CONTROL DAMPER

AFG501 ALUMINUM FEMA 361 LOUVER LOUVER TYPE RECOMMENDED SPECIFICATION

Fusible Link (replaceable) Horizontal Mount

When Time is Everything... We Manufacture in Days - Not Weeks!

FSD36, FSD36LP COMBINATION FIRE AND SMOKE DAMPER

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Installation, Operation and Maintenance Manual

Blast Protection Damper

SMOKE DAMPER - CLASS F MODEL BMSD

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

VOLU-probe. Pitot Airflow Traverse Probes. amca. Accurate airflow measurement for demanding applications. CERTIFIED RATInGS

RM-1200 Slim Round Control Damper

Transcription:

Model Application The is a low leakage high performance control damper with extruded aluminum airfoil blades. Blades are completely contained within the frame allowing the damper to be directly mounted to a louver, filter frame, or similar application with no blade interference. Smooth profile extruded aluminum airfoil blades insure the lowest resistance to airflow in HVAC systems with velocities up to 6000 fpm (30.5 m/s) and pressures up to 6 in. wg (1.5 kpa). is IECC (International Energy Conservation Code) compliant with a leakage rating of 3 cfm/ft 2 @ 1in. wg (55 cmh/m 2 @.25 kpa) or less. Ratings Pressures: Up to 6 in. wg (1.5 kpa) - pressure differential Velocity: 3000 to 6000 fpm (15.2-30.5 m/s) Leakage: Class 1A @ 1 in. wg. For more leakage ratings, see page 4. Temperature: Up to 250 F (121 C). Consult Greenheck for higher temperatures. Construction Standard Optional Frame Material Aluminum - Frame Material Thickness Frame Type.125 in. (3.2mm) minimum wall thickness 4 in. x 1 in. (102mm x 25mm) hat channel - Single Flange, Reverse Flange Blade Material Extruded Aluminum - Blade Type Airfoil - Blade Action Opposed Parallel Linkage Axle Bearings Plated steel out of airstream, concealed in jamb Synthetic (acetal) sleeve 304SS 304SS Axle Material Plated steel 304SS Blade Seals TPE Silicone Jamb Seals 304SS - Finish Size Limitations W x H Minimum Size Mill finish Single Section Maximum Size Baked Enamel, Epoxy, Hi Pro Polyester, Industrial Epoxy, Kynar/Hylar (70% Kynar), Anodize Multiple Section Inches 6 x 6 60 x 74 Unlimited mm 152 x 152 1524 x 1880 Unlimited Extruded Airfoil Blade Control Damper Narrowline Frame Construction W* * W and H dimension furnished approximately 1/4 in. (6mm) undersize. Flange Options 4 in. 4 in. Single Flange H* 1 1/2 in. (Typical) Reversed Flange Shown with optional internal mounted actuator. Blade Operation 4 in. 4 in. Parallel Blades Opposed Blades The can be mounted vertically or horizontal. Blades must be horizontal. Installation instructions available at www.greenheck.com.

Data Data This pressure drop testing was conducted in accordance with AMCA Standard 500-D using the three configurations shown. All data has been corrected to represent standard air at a density of.075 lb/ft 3 (1.201 kg/m 3 ). Actual pressure drop found in any HVAC system in a combination of many factors. This pressure drop information along with an analysis of other system influences should be used to estimate actual pressure losses for a damper installed in a given HVAC system. AMCA Test Figures Figure 5.3 illustrates a fully ducted damper. This configuration has the lowest pressure drop of the three test configurations because entrance and exit losses are minimized by straight duct runs upstream and downstream of the damper. Figure 5.2 illustrates a ducted damper exhausting air into an open area. This configuration has a lower pressure drop than Figure 5.5 because entrance losses are minimized by a straight duct run upstream of the damper. Figure 5.5 illustrates a plenum mounted damper. This configuration has the highest pressure drop because of extremely high entrance and exit losses due to the sudden changes of area in the system. 6D Figure 5.3 D 4 (W) (H) 3.14 Figure 5.2 Figure 5.5

R Data AMCA 5.2 12 in. x 12 in. (305mm x 305mm) 24 in. x 24 in. (610mm x 610mm) 36 in. x 36 in. (914mm x 914mm) 500 0.08 500 0.01 500 0.01 1000 0.31 1000 0.05 1000 0.04 1500 0.69 1500 0.11 1500 0.09 2000 1.19 2000 0.19 2000 0.16 2500 1.84 2500 0.30 2500 0.24 3000 2.67 3000 0.43 3000 0.35 3500 3.59 3500 0.58 3500 0.48 4000 4.64 4000 0.76 4000 0.62 12 in. x 48 in. (305mm x 1219mm) 500 0.01 1000 0.05 1500 0.11 2000 0.20 2500 0.30 3000 0.43 3500 0.59 4000 0.77 48 in. x 12 in. (1219mm x 305mm) 500 0.06 1000 0.23 1500 0.52 2000 0.91 2500 1.43 3000 2.05 3500 2.82 4000 3.69 AMCA 5.3 6D 12 in. x 12 in. (305mm x 305mm) 24 in. x 24 in. (610mm x 610mm) 36 in. x 36 in. (914mm x 914mm) 500 0.05 500 0.01 500 0.01 1000 0.20 1000 0.02 1000 0.02 1500 0.45 1500 0.05 1500 0.04 2000 0.76 2000 0.10 2000 0.07 2500 1.19 2500 0.15 2500 0.10 3000 1.70 3000 0.22 3000 0.15 3500 2.29 3500 0.30 3500 0.20 4000 2.97 4000 0.40 4000 0.27 12 in. x 48 in. (305mm x 1219mm) 500 0.01 1000 0.03 1500 0.07 2000 0.12 2500 0.19 3000 0.26 3500 0.36 4000 0.46 48 in. x 12 in. (1219mm x 305mm) 500 0.03 1000 0.13 1500 0.29 2000 0.51 2500 0.81 3000 1.16 3500 1.59 4000 2.09 AMCA 5.5 12 in. x 12 in. (305mm x 305mm) 24 in. x 24 in. (610mm x 610mm) 36 in. x 36 in. (914mm x 914mm) 500 0.1 500 0.03 500 0.03 1000 0.40 1000 0.12 1000 0.11 1500 0.88 1500 0.29 1500 0.26 2000 1.54 2000 0.52 2000 0.46 2500 2.41 2500 0.80 2500 0.72 3000 3.45 3000 1.14 3000 1.04 3500 4.75 3500 1.60 3500 1.43 4000 6.09 4000 2.14 4000 1.87 12 in. x 48 in. (305mm x 1219mm) 500 0.03 1000 0.12 1500 0.27 2000 0.49 2500 0.76 3000 1.11 3500 1.53 4000 2.00 48 in. x 12 in. (1219mm x 305mm) 500 0.08 1000 0.29 1500 0.63 2000 1.12 2500 1.76 3000 2.52 3500 3.40 4000 4.52 Greenheck Fan Corporation certifies that the model shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Programs. The AMCA Certified Ratings Seal applies to air performance ratings only.

Leakage Air leakage is based on operation between 32 F (0 C) and 120 F (49 C). Tested for leakage in accordance with ANSI/AMCA Standard 500-D, Figure 5.5. Tested for air performance in accordance with ANSI/AMCA Standard 500-D, Figures 5.2, 5.3, and 5.5. Torque Data are based on torque of 5.0 in. lb./ft 2 (0.56 N m) applied to close and seat the damper during the test. Maximum Damper Width 1 in. wg (0.25 kpa) 2 in. wg (0.5 kpa) Leakage Class* 3 in. wg (0.75 in. wg) 4 in. wg (1 kpa) 5 in. wg (1.25 kpa) 6 in. wg (1.5 kpa) 36 in. (914mm) 1A 1 1 1 1 1 48 in. (1219mm) 60 in. (1524mm) 1A 1 1 1 2 N/A 1A 2 2 N/A N/A N/A *Leakage Class Definitions The maximum allowable leakage is defined as the following: Leakage Class 1A - 3 cfm/ft 2 @ 1 in. wg (class 1A is only defined at 1 in. wg). Leakage Class 1-4 cfm/ft 2 @ 1 in. wg - 8 cfm/ft 2 @ 4 in. wg - 11 cfm/ft 2 @ 8 in. wg - 12.6 cfm/ft 2 @ 10 in. wg Multi-Section Assemblies Dampers larger than the maximum single section size, will be made up of a multiple of equal size sections. Multiple section dampers can be jackshafted together so that all sections operate together as shown below. Note: Dampers larger than 60 in. x 74 in. (1524mm x 1880mm) are not intended to be structurally self supporting. Additional horizontal bracing is recommended to support the weight of the damper and vertical bracing should be installed as required to hold against system pressure. 74 in. (1880mm) 48 in. (1219mm) 96 in. (2438mm)

Space Envelopes On dampers less than 18 in. (457mm) high, actuators may also require clearances above and/or below the damper frame. B and T dimensions are worst case clearance requirements for some dampers less than 18 in. (457mm) high. All damper sizes under 18 in. (457mm) high do not require these worst case clearances. If space availability above or below the damper is limited, each damper size should be individually evaluated. Damper frame T D Optional Jackshaft B Actuator Type/Model Height T B D Inches (mm) Inches (mm) AFBUP (-S) and >6 to <10 0 12 3 4 6 FSNF Series, Belimo MSxx20 Series, >10 to <18 0 2 6 Honeywell; 33x-2976 Series, Siemens >18 0 0 6 FSLF, LF and TFB Series, >6 to <10 0 3 1 2 6 Belimo >10 0 0 6 MSxx04 & MSxx09 >6 to <9 0 4 3 4 6 Series, Honeywell >9 0 0 6 >6 to <10 0 12 3 4 6 MS75xx Series, >10 to <18 0 7 6 Honeywell >18 0 0 6 >6 to <10 0 7 1 2 6 33x-4551 Series, >10 to <17 0 1 Siemens 2 6 >17 0 0 6 <12 N/A N/A N/A 331-2856, >12 to <18 0 2 Siemens 2 9 >18 0 0 9 This drawing depicts the worse case clearance requirements for an actuator with a jackshaft. 7 3/4 in. (197mm) 3 3/4 in. (95mm) Mounting External - includes extension pin (standoff bracket optional) External kit - actuator and all mounting hardware Internal - blade lever Actuator 5 3/8 in. (136.5mm) 4 in.

Specifications Control dampers meeting the following specifications shall be furnished and installed where shown on plans and/or as describe in schedules. Damper shall consist of: heavy gauge aluminum frame (0.125 in. [3.2mm] thick) with 4 in. (101mm) depth formed into a structural hat channel shape with reinforced corners; airfoil shaped extruded aluminum blades (0.063 in. [1.6mm] thick) with metal blade to blade overlap (seal to seal only contact is not acceptable); blades shall be completely symmetrical relative to their axle pivot point, presenting identical resistance to airflow and operation in either direction through the damper (blades that are nonsymmetrical relative to their axle pivot point or utilize blade stops larger than 1 2 in. [13mm] are unacceptable); 1 2 in. (13mm) dia. plated steel axles turning in synthetic (acetal) sleeve bearings; TPE blade seals; flexible stainless steel jamb seals; and external (out of the airstream) blade to blade linkage. Damper manufacturer s printed application and performance data including pressure, velocity, and temperature limitations shall be submitted for approval showing damper suitable for pressures to 6 in. wg (1.5 kpa), velocities to 6000 fpm (30.5 m/s), and temperatures up to 250 F (121 C). Damper manufacturer s printed performance data showing standard air leakage less than 3 cfm/ft 2 @ 1in. wg (55 cmh/ m 2 @ 0.25 kpa) in either direction through the damper shall be submitted for approval. Damper testing and ratings shall be developed in accordance with the latest edition of AMCA Standard 500-D. Basis of design is model. Copyright 2018 Greenheck Corporation Rev. 19 February 2018