HVAC Control & Balancing Dampers

Size: px
Start display at page:

Download "HVAC Control & Balancing Dampers"

Transcription

1 HVAC Control & Balancing Dampers Models VCD, MBD and RBD Selection Construction Performance H* W* August

2 HVAC Control and Balancing Dampers Commercial Control Dampers are used in buildings to regulate the flow of air in a HVAC system. They can be used in intake, exhaust, or mixed air applications. There are two categories of control dampers: Balancing Commercial Control Balancing Manual balancing dampers are control dampers that regulate the flow of air but are not intended to be used in applications as a positive shut off or for automatic control. These dampers are shipped with manual hand quadrants that can be locked in place. There are four balancing damper models available: MBD-10/10M is a single blade MBD-15 is a multi-blade MBDR-50 is a round blade Remote balancing dampers offer the same function as a manual balancing damper plus the added benefit of controlling the damper remotely at a diffuser or wall plate. These remote balancing dampers are ideal for applications where it is difficult to gain access to manually adjust the dampers to balance airflow. The EZ Balance remote control operates the damper motor by connecting to the wall, ceiling, or diffuser mounted RJ11 connector. There are two remote balancing damper models available: RBD-10 (single blade) RBDR-50 (round blade) MBD-10 Single blade * shown with optional standoff bracket MBD-15 Multi-blade Meets SMACNA recommended construction requirements MBDR-50 Round blade RBD-10 Single blade * Actuator shipped as a kit for field installation RBDR-50 Round blade Factory-mounted actuator 2

3 Manual and Remote Balancing Dampers A wide variety of accessories are available for the RBD and RBDR series. They include: Diffuser connector Wall plates with ports Round wall/ceiling plate with single port Single gang outlet box EZ Balance handheld remote kit Plenum and non-plenum rated cables Cable connectors Quick Selection Chart MBD-10 MBD-10M MBD-15 MBDR-50 RBD-10 RBDR-50 Single Blade X X X Blade Profile 3V X Round X X Material Galvanized X X X X X X 20 (1) X X Frame Gauge 18 (1.3) X X X 16 (1.5) X Bearings Synthetic X X X X Bronze O Axles Steel X X X Linkage Material Steel X Manual Quadrant X X X X 1-1/2 in. Standoff Bracket O O X O Actuator 2 in. Standoff Bracket O O O O Remote Powered 9 Volt Actuator X X Sizing Inches (mm) X = Standard Minimum Maximum Single Section Maximum Multi-Section O = Optional 6 x 4 (152 x 102) 36 x 12 (914 x 305) 8 x 4 (203 x 102) 36 x 12 (914 x 305) x 6 (152 x 152) 48 x 60 (1219 x 1524) 96 x 96 (2438 x 2438) 4 (102) 24 (610) 6 x 4 (152 x 102) 36 x 12 (914 x 305) EZ Balance handheld remote kit 4 (102) 24 (610) Pressure RBD-10 RBDR-50 MBD-10/10M MBD-15 MBDR Feet per Minute (maximum) RBD-10 RBDR-50 MBD-10/10M MBD-15 MBDR Inches wg (maximum) 3

4 Volume Control Dampers VCD Series Commercial Control Commercial control dampers regulate the flow of air in the same manner as manual balancing dampers, in addition, they can be used as a positive shutoff or for automatic control. There are three types of commercial control dampers available: Volume control VCD series Insulated control ICD series Air measuring control - AMD series Blade Manual Quadrant Kit Bearing Shaft Extension Jamb Seal Axle Blade Seal Frame Linkage Variable Symmetric Blade Design (VSB) Part of Greenheck s unique approach to damper construction, Variable Symmetric Blade design (VSB), uses two principles to increase damper performance. First, all damper blades are symmetric about their axis. Second, any combination of 4, 5, 6, and 7 in. (102, 127, 152, and 178mm) blade widths are used in a single damper. These two features are part of Greenheck s standard construction and provide the following advantages: Free Area Free Area Increases Mounting Flexibility - Symmetrical blades have identical operating characteristics regardless of airflow direction. This allows a Greenheck control damper to be mounted in either direction of flow, an advantage when installing with space constraints. Increases Free Area - Traditional damper designs with a single blade width require oversized blade stops, limiting free area when the blades are open (Figure 1). Greenheck is able to reduce height or eliminate blade stops, which maximizes free area and increases damper performance (Figure 2). Reduces Actuator Torque - If an unsymmetrical blade closes against airflow, a large amount of torque is needed because the air distribution is unbalanced. Greenheck s VSB design balances airflow on each side of a symmetrical blade, reducing the torque required to operate the damper. The use of symmetrical blades has allowed Greenheck to reduce the sizes and quantities of actuators used on dampers (Figure 3). Competitor Airflow works against actuator Actuator Torque Unbalanced Blade Requires Higher Torque Greenheck with low profile frame Figure 1 Figure 2 Figure 3 Airflow works against actuator Airflow works with actuator Actuator Torque Balanced Blade Requires Less Torque 4

5 Design and Construction Features Blades 3V blades are fabricated from a single thickness of 16 ga. (1.5mm) galvanized or stainless steel incorporating three longitudinal V-Type grooves running the full length of the blade to increase strength. This blade is standard on models VCD-15, 18, 20, 20V, 23, 23V, and SEVCD-23, designed for low to medium velocity and pressure applications. Airfoil blades are constructed of double-skin galvanized steel, stainless steel, or heavy-gauge extruded aluminum. This blade design results in lower resistance to airflow and increased strength that is typically used in high pressure systems. Airfoil blades are standard on models VCD-33, 33V, 34, 40, 42, 42V, 43, 43V and SEVCD-33. 3V Blade Steel Airfoil Blade Aluminum Airfoil Blade Parallel Versus Opposed Blade Operation Greenheck control dampers are offered with either parallel or opposed blades. Each style has distinguishing characteristics in regard to the type of operation required. Parallel blade operation - This configuration requires the damper blades to rotate in the same direction, parallel to one another. Parallel blade orientation is typically used when the damper operates in two positions, open or closed. Opposed blade operation - Adjacent damper blades rotate opposite one another under opposed blade configuration. Opposed blade configuration is typically used on dampers that modulate airflow. Parallel Blades Opposed Blades Frame Greenheck control dampers utilize a 5 in. x 1 in. (127mm x 25mm) hat channel frame made of 16 ga. (1.5mm) steel, 16 ga. (1.5mm) stainless steel, or in. (3mm) aluminum. Each frame is built with four separate pieces of material and joined by our Tog-L-Loc process resulting in the following advantages: Rigid frame - When two pieces of 16 ga. (1.5mm) steel are joined by the Tog-L-Loc system, the joint has an equivalent thickness of 10 ga. (3.5mm) steel. Increased corrosion resistance - High temperatures from welding remove the galvanized finish from damper frames. The Tog-L-Loc process does not use heat, so Greenheck damper frames have greater corrosion resistance by retaining the galvanized coating. Tog-L-Loc Reinforced Corner Optimal free area - On dampers that are 17 in. (432mm) high or less, Greenheck uses a low profile top and bottom frame section to maximize free area. Square frame - Many damper manufacturers construct each frame from a single piece of sheet metal, formed into shape by bending at three corners and spot welding in one. This type of construction can produce weak corners that are not necessarily 90º, resulting in a frame that is out-of-square. Symptoms of out-of-square frames include blades that do not close properly and reduced leakage performance. Using four separate frame components (top, bottom, and two sides), Greenheck s Tog-L-Loc process results in four sturdy, 90º joints. This ensures that each Greenheck damper is square and provides optimum performance in the field. There are five frame options available: Channel Frame (standard) Single Flange Single Reverse Flange Double Flange Quick Connect (VCD-43, -43V; ICD Series) Standard Frame Single Flange (actuator side) Single Reverse Flange (opposite actuator) Double Flange Quick Connect 5

6 Design and Construction Features Frame Options The channel frame style allows a damper to be insert mounted into an opening without being concerned about the linkage sticking out past the frame. The single and single reverse flange frame can be insert mounted or directly mounted to the wall, mating surface or bulkhead. The quick connect frame design is extruded to match up to a TDC, TDF, or Ductmate connection to allow the damper to be cleated to the ductwork. This illustration depicts how to mount a damper into a plenum wall. Linkage Traditional damper linkages are found in the airstream, adding to the pressure drop of the damper blades and frame. Greenheck control dampers have blade linkage concealed in the frame to prevent additional pressure drop and unwanted noise. With standard plated steel construction (stainless steel optional), the linkage is engineered to accurately control each and every blade without need for adjustment. No Top or Bottom Greenheck s standard control dampers are designed for installation in any position with the blades horizontal. The damper can be turned over so the actuator is on the left or right side. Optional vertical blade models can be turned with the actuator at the top or bottom. Standard Vertical Blade Multi-Section Dampers Each of Greenheck s VCD control dampers have a maximum size for a single damper section or panel. These sections vary from 48 in. wide x 60 in. high (1219mm x 1524mm) to 60 in. wide x 74 in. high (1524mm x 1880mm). Dampers larger than a single section will be made up of equal size sections which, depending upon model and size, may be shipped as a single complete assembly or as separate sections for field assembly. Multi-section damper assemblies are supplied with a coupler or factory installed jackshaft so all sections operate together. Factory Installed Jackshaft Coupled (concealed between frames) Damper assemblies (larger than one section) are not designed to be structurally self-supporting. Additional horizontal bracing is recommended for support. Vertical bracing should be installed if required to hold against system pressure. 6

7 Options and Accessories QR Codes Greenheck has added QR (Quick Response) codes to the labels on commercial control and air measuring dampers. When you scan the QR code with your smartphone, it will link to based on the model. Paint Finishes A wide variety of paint finishes are available including: Anodize Industrial Epoxy Baked Enamel Kynar /Hylar Epoxy Permatector Hi Pro Polyester See color charts on for standard color offering. Factory Sleeve Option Greenheck control dampers are available with factory furnished sleeves in lengths up to 48 in. (1219mm). Sleeves are constructed out of 10 through 20 ga. (3.25 through 0.91 mm) galvanized steel. When dampers are installed in factory sleeves, the A dimension specifies the location of damper within the sleeve. Sleeve A Damper Location CL Damper Frame L Damper D* D* + 2 in. sq. Transitions Greenheck control dampers can be supplied with the appropriate transition option in applications where dampers require installation in round or oval openings. Rectangular dampers are constructed zero, 1 inch (25mm), or 2 (51mm) larger than the transition dimensions and installed in a factory sleeve. The sleeve is transitioned at each end to the appropriate round, oval, or rectangular size. Type O Type R Type C Transition options available Security Bars When security becomes an issue, Greenheck offers optional factory-installed security bars. Security bars are factory welded into a 10 ga. (3.5mm) sleeve. Open Close Indicator - OCI The OCI contains two single pole, single throw switches used to indicate damper blade position. The switches provide positive open and closed signals when used in conjunction with remote indicator lights. Switches are physically linked to a damper blade and therefore give a true representation of the damper s position. 7

8 Wide Range of Actuators Greenheck has a wide range of manual, electric, and pneumatic actuators for use with control dampers. Actuators can be installed at the factory or shipped loose with the necessary linkage and brackets required for mounting. Each damper and actuator is cycle tested in our factory before the final product is shipped, ensuring Greenheck quality and trouble free operation in the field. Manual Hand Quadrant See Figure 5 Location Internal or External Figure 5 Manual Quadrant Electric Actuator Checklist See Figures 6 & 7 Power Supply 24 VDC, 24 VAC, 120 VAC, and 240 VAC Frequency Operation Spring Return (spring will drive damper to original starting point) Power Open or Power Closed Operating Mode Two position (damper position is open or closed) Modulating (damper position determined by modulating control signal) Floating (damper can be stopped anywhere between open and closed) Fail Direction (for spring return only) Open or Closed Location Internal or External Control Signal (for modulating only) 0-10 VDC, 2-10 VDC or 4-20 madc NEMA Enclosure 1, 3, 4, 4X, or 7 (specify one per application) Accessories Auxiliary Switches Transformers Greenheck s most commonly used electric actuator manufacturers are Honeywell, Belimo, and Siemens. Contact your Greenheck representative for other options. Figure 6 Electric External Mount Figure 7 Electric Internal Mount Pneumatic Actuator Checklist See Figure 8 Power Supply 20 psi Operation Spring Return (spring will drive damper to original starting point) Operating Mode Two Position (damper position is open or closed) Modulating (damper position determined by modulating pressure signal) Fail Direction (for spring return only) Open or Closed Location Internal or External Control Signal (for modulating only) 3-15 psi Accessories Solenoid Valves or Positioners Greenheck s most commonly used pneumatic actuator manufacturers are Siemens and Invensys. Contact your Greenheck representative for other options. Figure 8 Pneumatic 8

9 Damper Performance Testing Criteria Pressure drop testing was conducted in accordance with AMCA Standard 500-D using the three configurations shown. All data has been corrected to represent standard air at a density of.075 lb/ft 3 (1.2 kg/m 3 ). Actual pressure drop found in an HVAC system is a combination of many factors. This pressure drop information, along with an analysis of other system influences should be used to estimate actual pressure losses for a damper installed in an HVAC system. Figure 5.3 Illustrates a fully ducted damper. This configuration has the lowest pressure drop of the three test configurations because entrance and exit losses are minimized by straight duct runs upstream and downstream of the damper. Figure 5.2 Illustrates a ducted damper exhausting air into an open area. This configuration has a lower pressure drop than Figure 5.5 because entrance losses are minimized by a straight duct run upstream of the damper. Figure 5.5 Illustrates a plenum mounted damper. This configuration has the highest pressure drop because of high entrance and exit losses due to the sudden changes of area in the system. 5D 6D Figure 5.3 5D Figure 5.2 Figure 5.5 D= 4 (W) (H) 3.14 D = Duct length W = Damper width H = Damper height Greenheck Fan Corporation certifies that the model AMD-23 and 33, VCD-15, 20 and VCD-40 shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Programs. The AMCA Certified Ratings Seal applies to Air Performance ratings only. Greenheck Fan Corporation certifies that the model VCD-18, 23, 33, 34, 43, SEVCD-23 and 33 shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Programs. The AMCA Certified Ratings Seal applies to Air Leakage and Air Performance ratings. Greenheck Fan Corporation certifies that the model ICD-44 and ICD-45 shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Programs. The AMCA Certified Ratings Seal applies to Air Leakage, Air Performance and Energy Efficiency ratings. 9

10 Pressure Drop Data VCD-15, 18, 20, 23 Galvanized 3V blade Economic VCD-15 and VCD-18 Blade and jamb seals VCD-18 and 23 SEVCD stainless steel 3V blade 316 stainless steel construction Blade and jamb seals 12x12 24x24 36x36 12x48 48x12 AMCA figure VCD-20V and 23V Vertical 3V blade Blade and jamb seals VCD-23V 12x12 24x24 36x36 12x48 48x12 AMCA figure VCD-33 and 34 Galvanized airfoil blade Insulated airfoil VCD-34 Blade and jamb seals SEVCD stainless steel airfoil blade 316 stainless steel construction Blade and jamb seals 12x12 24x24 36x36 12x48 48x12 AMCA figure

11 Pressure Drop Data VCD-33V Vertical galvanized airfoil blade Blade and jamb seals 12x12 24x24 36x36 12x48 48x12 AMCA figure VCD-40 Extruded aluminum airfoil blade Blades contained within the frame Blade and jamb seals 12x12 24x24 36x36 12x48 48x12 AMCA figure VCD-42 Extruded aluminum airfoil blade Galvanized frame Blade and jamb seals 12x12 24x24 36x36 12x48 48x12 AMCA figure

12 Pressure Drop Data VCD-42V Vertical extruded aluminum airfoil blade Galvanized frame Blade and jamb seals 12x12 24x24 36x36 12x48 48x12 AMCA figure VCD-43 Extruded aluminum airfoil blade Aluminum frame Blade and jamb seals 12x12 24x24 36x36 12x48 48x12 AMCA figure VCD-43V Vertical extruded aluminum airfoil blade Aluminum frame Blade and jamb seals 12x12 24x24 36x36 12x48 48x12 AMCA figure

13 Pressure Drop Data VCDR-50 and 53 Insert type round single blade Blade seals VCDR AMCA figure VCDRM-50 and 53 Insert type round multi-blade Blade seals VCDRM AMCA figure Pressure Drop Comparison Greenheck compared the AMCA licensed pressure drop data of a VCD in. wide x 12 in. high (305mm x 305mm) versus a competitor s equivalent 12 in. wide x 12 in. high (305mm x 305mm) damper. Both dampers were installed in an identical system which drew 2000 ft./min of airflow through them. The results were dramatic! AMCA Licensed Pressure Drop Data 10.0 Pressure Drop (in. wg) in. wg 0.08 in. wg Competitor Greenheck VCD ,000 2,000 10,000 (ft./min) AMCA Figure in. x 12 in. Fabricated Airfoil Damper 13

14 Air Leakage Performance Three common code energy standards that pertain to dampers are: ASHRAE Standard Energy Standard for Buildings except Low-Rise Residential Buildings California Title 24 IECC - International Energy Conservation Code Here are the primary requirements for dampers based on each standard: ASHRAE Standard 90.1 (2010 edition) states that maximum damper leakage at 1 in. wg for a : non-motorized damper is 20 cfm/ft 2 or motorized damper is 4 cfm/ft 2. ( See Table from ASHRAE Standard 90.1) California Title 24 (2013 edition, section ) states that the dampers shall be certified in accordance with AMCA Publication 511 to have a maximum leakage of 10 cfm/ft 2 at 1 in. wg. The dampers have been tested and are able to open and close against the rated airflow and pressure of the system after 60,000 damper opening and closing cycles. IECC (2012, section C ) that outdoor air supply and exhaust opening be supplied with Class 1A motorized dampers with a maximum leakage rate of 4 cfm/ft 2 at 1 in. wg when tested in accordance with AMCA 500D. Greenheck s volume control dampers meets the requirements of ASHRAE, California Title 24 and IECC. Air Leakage Data Air leakage is based on operation between 32 and 120 F (0 and 49 C). Tested for leakage in accordance with ANSI/AMCA Standard 500-D, Figure 5.5. Tested for air performance in accordance with ANSI/AMCA Standard 500-D, Figures 5.2, 5.3 and 5.5. Torque Data is based on a torque of 5.0 in-lb/ft² (0.56 N m) applied to close and seat the damper during the test. VCD-18 Leakage Class* Maximum Damper Width 1 in. wg (0.25 kpa) 2 in. wg (0.5 kpa) 48 in. (1219mm) 1A 1 VCD-23, SEVCD-23 Leakage Class* Maximum Damper Width 1 in. wg (0.25 kpa) 4 in. wg (1 kpa) 5 in. wg (1.2 kpa) 48 in. (1219mm) 1A 1 1 VCD-43 Maximum Damper Width 1 in. wg (0.25 kpa) 4 in. wg (1 kpa) Leakage Class* 8 in. wg (2 kpa) 10 in. wg (2.5 kpa) 60 in. (1524mm) 1A Torque Data is based on a torque of 7.0 in-lb/ft² (0.79 N m) applied to close and seat the damper during the test. VCD-33, 34 SEVCD-33 Maximum Damper Width 1 in. wg (0.25 kpa) 4 in. wg (1 kpa) Leakage Class* 8 in. wg (2 kpa) 10 in. wg (2.5 kpa) 60 in. (1524mm) 1A

15 Specialty Control Dampers *Leakage Class Definitions The maximum allowable leakage is defined by AMCA as the following: Leakage Class 1A - 3 cfm/ft 1 in. wg (Class 1A is only defined at 1 in. wg). Leakage Class 1-4 cfm/ft 1 in. wg - 8 cfm/ft 4 in. wg - 11 cfm/ft 8 in. wg cfm/ft 10 in. wg Model Maximum Leakage cfm/sq. ft. (cmh/sq.m) 1 in. wg (.25 4 in.wg (1 kpa) VCD-23V, 43V Class 1A Class 1 VCD-40 Class 1A Class 1 VCD-33, 42, 42V Class 1A Class 1 VCDR-53 Class 1 Class 1 VCDRM-53 Class 1 Class 1 Greenheck Fan Corporation certifies that the model VCD-18, 23, 33, 34, 43, SEVCD-23 and 33 shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Programs. The AMCA Certified Ratings Seal applies to Air Leakage and Air Performance ratings. Greenheck Fan Corporation certifies that the model ICD-44 and ICD-45 shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Programs. The AMCA Certified Ratings Seal applies to Air Leakage, Air Performance and Energy Efficiency ratings. Specialty Control Dampers Damper/Louver in a Common Sleeve Greenheck can provide a damper and louver in a common sleeve for applications requiring single unit assembly. This assembly makes it convenient for installing in the field as one unit instead of dealing with multiple units (consult factory for more information). HEIGHT DAMPER SLEEV LOUVER Face & Bypass Dampers The face and bypass dampers are used in applications where two dampers are connected together allowing one damper to open while the other damper closes. The FBH-43 is horizontal style (side-by-side). The FBV-43 is vertical style (stacked) DAMPER LOCATION SLEEVE LENGTH LEFT SIDE OF SLEEVE ELEVATION FBH FBV 15

16 Specialty Control Dampers ICD - Insulated Control Damper Greenheck s ICD dampers were developed for applications where it is necessary to minimize the thermal transfer and reduce condensation. ICD series dampers meet Class 1A leakage of less than 3 cfm/sq. 1 in. wg (55 cmh/m kpa). ICD series dampers can be used in applications down to -70 F (-56 C) and up to 200 F (93 C) for: Cold food storage warehouses Buildings/warehouse Rooftop intake or exhaust AMCA Certified Energy Efficiency Performance A damper s Thermal Efficiency Ratio (E) is a comparison of the thermal performance of the tested damper with a standard reference damper. A damper that is twice as efficient as the reference damper would have an E of 100%. Cross section of thermally broken frame and blade ICD-44 ICD-45 Maximum - ft/min (m/s) 4000 (20.3) 4000 (20.3) Maximum Pressure - in. wg (kpa) 8 (2) 8 (2) Thermal Efficiency Ratio (E) 593% 941% Temperature Range - F (C ) -70 to 200 (-56 to 93) -70 to 200 (-56 to 93) Frame Insulated Thermally Broken Aluminum - X Aluminum X - Channel X O Frame Type Quick Connect O X Reverse Flange O O Single Flange O O Blade Action Parallel O O Opposed X X Blade Type Insulated Thermally Broken X X Blade Material Extruded Aluminum Airfoil X X Blade Seal Silicone X X Jamb Seal Stainless Steel X - Silicone O X X = Standard O = Optiona Air Measuring Products Airflow measuring products are used to accurately measure and control air. Applications include meeting the minimum outdoor air requirements of ASHRAE Standard 62 or California Title 24 by providing accurate monitoring and control of outside air. Why is outside air measurement important? There are many significant benefits to monitoring outside air volumes. First, by measuring the amount of outside air coming into a building, you can be assured the building is in compliance with all applicable indoor air quality codes including ASHRAE Standard 62 and California Title 24. Meeting these minimum requirements reduces indoor airborne viruses and bacteria which can lead to Sick Building Syndrome. Studies have shown that inhabitants in buildings that are under ventilated suffer from reduced productivity levels. AMS 16

17 Specialty Control Dampers The second major advantage to monitoring outside air volumes is it eliminates costly over ventilation. In addition to increased energy costs associated with heating and cooling of outside air, over ventilation causes an increase in humidity that can result in mold development. The AMS is an accurate airflow measuring station that is furnished with a properly sized pressure transducer that outputs a 0-10 VDC signal proportional to cfm. The AMS is compatible with a field-supplied controller or a factory-supplied LON controller (sold separately). AMD series dampers were developed as an accurate low cost alternative to typical air measuring products. The AMD series comes standard with a modulating actuator and a properly sized pressure transducer that outputs a 0-10 VDC signal proportional to cfm. Many control contractors like to use their own controllers. A large label on every AMD damper shows the controls contractor everything needed to program their own controller. Field-supplied controllers can use the transducer s signal along with the flow formula (provided) to regulate a modulating actuator to the target set point. A factory-supplied controller is also available. The AMD series is also available with a factorysupplied LON controller that accepts a target flow set point as an input (either analog or digital) and outputs a 0-10 VDC signal proportional to the airflow that can be used to position a damper. Quick Selection Chart ft/min (m/s) Temperature Range F ( C) Factory Calibration Required AMD-42 featuring an extruded airfoil blade control blade AMS AMD-23 AMD-33 AMD-42 AMD-42V 2000 (10.2) -20 to 180 (-29 to 82 ) 2000 (10.2) -20 to 180 (-29 to 82 ) 2000 (10.2) -20 to 180 (-29 to 82 ) 2000 (10.2) -20 to 180 (-29 to 82 ) AMD-42V featuring an extruded airfoil vertical blade control damper 2000 (10.2) -20 to 180 (-29 to 82 ) Accuracy 5% 5% 5% 5% 5% Measures Airflow Regulates Airflow Volume Factory-Supplied Transducer Factory-Supplied Controller Airflow Straightener Blade Action Parallel Unit Depth in. (mm) 8 (203) 12 (305) 12 (305) 12 (305) 12 (305) Maximum Size 60 x 48 (1524 x 1219) 144 x 148 (3658 x 3759) AMD-23 featuring a 3V blade control damper 144 x 148 (3658 x 3759) 144 x 148 (3658 x 3759) 74 x 60 (1880 x 1524) Quick Build Program AMD-33 featuring a fabricated airfoil blade control damper 17

18 Volume Control Dampers Quick Selection Chart Blade Profile Frame Material Blade Material Frame Gauge Blade Seals Jamb Seals Bearings Axles Linkage Material Accessories Sizing (mm) Ratings 18 X = Standard O = Optional Single Blade VCD-15 VCD-18 VCD-20 VCD-20V VCD-23 VCD-23V VCD-33 VCD-33V VCD-34 VCD-40 3V X X X X 3V-Vertical Blade X X Airfoil-Vertical Blade Airfoil-Insulated Airfoil X X Galvanized X X X X X X X X X 304 Stainless Steel O O O O O O O 316 Stainless Steel Aluminum Galvanized X X X X X X X X X 304 Stainless Steel O O O O O O O 316 Stainless Steel Aluminum X X X X X X X X X 12 O O O O O O O Aluminum.125 (3.2) TPE X X X X X X X Silicone O O O O O O 304 Stainless Steel X X X X X X X 316 Stainless Steel Synthetic X X X X X X X X X X Bronze O O O O O O O O O O 304 Stainless Steel O O O O O O O O O O 316 Stainless Steel Steel X X X X X X X X X X 304 Stainless Steel O O O O O O O O 316 Stainless Steel Steel X X X X X X X X X X 304 Stainless Steel O O O O O O O O 316 Stainless Steel Sleeves O O O O O O O O O Transitions O O O O O O O O O Actuators* O O O O O O O O O O Flanges** O O O O O O O O Retaining Angles O O O O O O O O O O Security Bars O O O O O O Minimum Size Maximum Single Section Size Maximum Multi- Section Size Max. ft/min (m/s) Max. Pressure in. wg (kpa) 48x60 (1219x1524) 72x60 (1829x1524) 1500 (7.6) 2 (.5) 48x60 (1219x1524) 72x60 (1829x1524) 1500 (7.6) 2 (.5) 48x74 (1219x1880) Unlimited 3000 (15.2) 5 (1.2) * Actuators include manual, 24V, 120V, 240V, and pneumatic. ** Flanges include single, single reverse, and double flange. *** The inside of the blade is not painted on airfoil blade dampers. 74x48 (1880x1219) 148x96 (3759x2438) 3000 (15.2) 5 (1.2) 48x74 (1219x1880) Unlimited 3000 (15.2) 5 (1.2) 74x48 (1880x1219) 148x96 (3759x2438) 3000 (15.2) 5 (1.2) 60x74 (1524x1880) Unlimited 4000 (20.3) 10 (2.5) X 74x60 (1880x1524) 148x96 (3759x2438) 4000 (20.3) 10 (2.5) X 60x74 (1524x1880) Unlimited 4000 (20.3) 10 (2.5) X X 60x74 (1524x1880) Unlimited 6000 (30.5) 6 (1.5)

19 Volume Control Dampers Quick Selection Chart Blade Profile Frame Material Blade Material Frame Gauge Blade Seals Jamb Seals Bearings Axles Linkage Material Accessories Sizing (mm) Ratings X = Standard O = Optional VCD-42 VCD-42V VCD-43 VCD-43V SEVCD-23 SEVCD-33 VCDR-50 VCDR-53 VCDRM-50 VCDRM-53 Single Blade X X 3V X X X 3V-Vertical Blade Airfoil X X X Airfoil-Vertical Blade X X Airfoil-Insulated Galvanized X X X X X X 304 Stainless Steel O O O O 316 Stainless Steel X X Aluminum X X Galvanized X X X X 304 Stainless Steel O O O O 316 Stainless Steel X X Aluminum X X X X 20 X X 16 X X X X O O 14 O O X X 12 O O 10 O O Aluminum.125 (3.2).125 (3.2) EPDM X Vinyl TPE X X X X X X Silicone O O O O O O O 304 Stainless Steel X X X X X 316 Stainless Steel X X Synthetic X X X X Bronze O O O O X X X X 304 Stainless Steel O O O O O O O O 316 Stainless Steel X X Steel X X X X X X X X 304 Stainless Steel O O O O O O O O 316 Stainless Steel X X Steel X X X X X X 304 Stainless Steel O O O O O O 316 Stainless Steel X X Sleeves O O O O O O Transitions O O O O Actuators* O O O O O O O O O O Flanges** O O O O O O Retaining Angles O O O O Security Bars O Minimum Size Maximum Single Section Size Maximum Multi- Section Size Max. ft/min (m/s) Max. Pressure in. wg (kpa) 60x74 (1524x1880) Unlimited 6000 (30.5) 6 (1.5) 74x60 (1880x1524) 148x96 (3759x2438) 6000 (30.5) 6 (1.5) 60x74 (1524x1880) 288 x 222 (7315 x 5639) 6000 (30.5) 10 (2.5) * Actuators include manual, 24V, 120V, 240V, and pneumatic. ** Flanges include single, single reverse, and double flange. *** The inside of the blade is not painted on airfoil blade dampers. 74x60 (1880x1524) 148x96 (3759x2438) 6000 (30.5) 6 (1.5) 48x74 (1219x1880) 60x74 (1524x1880) 4 (102) 24 (610) 4 (102) 24 (610) 10 (254) 36 (914) 10 (254) 36 (914) Unlimited Unlimited NA NA NA NA 3000 (15.2) 5 (1.2) 4000 (20.3) 10 (2.5) 3000 (15.2) 4 (1) 3000 (15.2) 4 (1) 2500 (12.7) 5 (1.2) 2500 (12.7) 5 (1.2) 19

20 Drive Arrangement Definition Each damper is given a drive arrangement code to help describe the construction of the damper. The following breaks down what each number and letter represents. 22-2FEL Number of sections wide 2 Number of sections high 3 Number of actuators or manual quadrants 4 Who supplies the actuators or manual quadrants F - Factory C - Customer Supplied (field mounted) 5 Actuator or manual quadrant mounting E - External I - Internal B - Both internal and external 6 Actuator or manual quadrant location L - Left-hand drive R - Right-hand drive B - Both right and left 7 Number of jackshafts Jackshaft Actuator or Manual Quadrant Damper Width Damper Height Enjoy Greenheck s extraordinary service, before, during and after the sale. Greenheck offers added value to our wide selection of top performing, energy-efficient products by providing several unique Greenheck service programs. Our Quick Delivery Program ensures shipment of our in-stock products within 24 hours of placing your order. Our Quick Build made-to-order products can be produced in or 15-day production cycles, depending upon their complexity. Greenheck s free Computer Aided Product Selection program (CAPS), rated by many as the best in the industry, helps you conveniently and efficiently select the right products for the challenge at hand. Greenheck has been Green for a long time! Our energy-saving products and ongoing corporate commitment to sustainability can help you qualify for LEED credits. Our 3D service allows you to download at no charge lightweight, easy-to-use AutoDesk Revit 3D drawings for many of our ventilation products. Find out more about these special Greenheck services at greenheck.com Our Commitment As a result of our commitment to continuous improvement, Greenheck reserves the right to change specifications without notice. Specific Greenheck product warranties are located on greenheck.com within the product area tabs and in the Library under Warranties. Prepared to Support Green Building Efforts P.O. Box 410 Schofield, WI Phone (715) greenheck.com 00.DMP.1004 R xx Copyright 2013 Greenheck Fan Corp.

HVAC Control & Balancing Dampers

HVAC Control & Balancing Dampers HVAC Control & Balancing Dampers Models VCD, MBD and RBD Selection Construction Performance H* W* 1June 2017 Design and Construction Features Bearing Shaft Extension Jamb Seal Commercial Control Dampers

More information

Air Measuring Products AMD AMS IAQ

Air Measuring Products AMD AMS IAQ Air Measuring Products AMD AMS IAQ January 1 2012 Air Measuring Products Why is outside air measurement important? There are many significant benefits to monitoring outside air volumes. By measuring the

More information

HVAC Control Damper Models VCD and MBD. Selection Construction Performance

HVAC Control Damper Models VCD and MBD. Selection Construction Performance HVAC Control Damper Models VCD and MBD Selection Construction Performance November 2006 HVAC Control and Manual Balancing Dampers Greenheck HVAC control dampers bring the same quality engineering and manufacturing

More information

Air Measuring Products. AMS Thermal Dispersion Pressure Differential

Air Measuring Products. AMS Thermal Dispersion Pressure Differential Air Measuring Products AMS Thermal Dispersion Pressure Differential August 2014 1 Airflow Measuring Technologies Greenheck airflow measuring products are available with either differential pressure based

More information

AMD-33 Air Measuring Station with VCD-33 Control Damper

AMD-33 Air Measuring Station with VCD-33 Control Damper Application and Design Construction Standard Optional Frame Material Galvanized Steel - Frame Material Thickness 16 ga. (1.5mm) 12 ga. (2.7mm) Frame Type 5 in. x 1 in. hat channel - Blade Material Galvanized

More information

VCD-23. Flange Options. Size Limitations

VCD-23. Flange Options. Size Limitations Application and Design The series is a ruggedly built low leakage control damper intended for application in low to medium pressure and velocity systems. A wide range of electric and pneumatic actuators

More information

AMD-33. Air Measuring Station with VCD-33 Control Damper. Application and Design. Features & Control Options

AMD-33. Air Measuring Station with VCD-33 Control Damper. Application and Design. Features & Control Options Application and Design The combines the functionality of an accurate airflow measuring station and a low leakage control damper into one compact assembly that both measures and regulates airflow volumes

More information

AMD-42V Air Measuring Station with VCD-42V Control Damper

AMD-42V Air Measuring Station with VCD-42V Control Damper Application and Design Construction Standard Optional Frame Material Galvanized Steel - Frame Material Thickness 16 ga. (1.5mm) 12 ga. (2.7mm) 14 ga. (2mm) Frame Type 5 in. x 1 in. hat channel - Blade

More information

AMD-42 Air Measuring Station with VCD-42 Control Damper

AMD-42 Air Measuring Station with VCD-42 Control Damper Application and Design W x H Construction Standard Optional Frame Material Galvanized Steel - Frame Material Thickness External Minimum Size 16 ga. (1.5mm) Internal Single Section Maximum Size Multiple

More information

Model VCD-34. Low Leakage Insulated Airfoil CONTROL DAMPER. Ratings (See page 3 for specific limitations) Flange Options.

Model VCD-34. Low Leakage Insulated Airfoil CONTROL DAMPER. Ratings (See page 3 for specific limitations) Flange Options. Application and Design The Series is a ruggedly built low leakage control damper with thermally insulated blades. The is intended for application in medium pressure and velocity systems. This model also

More information

Baked Enamel, Epoxy, Hi Pro Polyester, Industrial Epoxy, Kynar/Hylar (70%) Permatector. Single or Reverse Flange 8 x 6 (203 x 178)

Baked Enamel, Epoxy, Hi Pro Polyester, Industrial Epoxy, Kynar/Hylar (70%) Permatector. Single or Reverse Flange 8 x 6 (203 x 178) Application and Design The is an extremely low leakage damper designed to meet the highest standards established for commercial control dampers. The is intended for application in medium to high pressure

More information

Model VCD-40. Extruded Airfoil Blade Control Damper Narrowline Frame Construction. Application. Ratings. Flange Options.

Model VCD-40. Extruded Airfoil Blade Control Damper Narrowline Frame Construction. Application. Ratings. Flange Options. Model Application The is a low leakage high performance control damper with extruded aluminum airfoil blades. Blades are completely contained within the frame allowing the damper to be directly mounted

More information

VCD-23. Low Leakage CONTROL DAMPER

VCD-23. Low Leakage CONTROL DAMPER Application and Design The series is a ruggedly built low leakage control damper intended for application in low to medium pressure and velocity systems. A wide range of electric and pneumatic actuators

More information

Model SEVCD-33. Low Leakage Airfoil Control Damper. Application and Design. Ratings (See page 3 for specific limitations) Blade Operation

Model SEVCD-33. Low Leakage Airfoil Control Damper. Application and Design. Ratings (See page 3 for specific limitations) Blade Operation Application and Design The is a severe environment 316SS ultra low leakage control damper with rugged stainless steel airfoil blades designed to meet the highest standards established for commercial control

More information

Thermal Isolation Break. Frame Type Channel Quick Connect Single or Reverse Flange Blade Action Parallel Opposed Parallel Opposed Parallel Opposed

Thermal Isolation Break. Frame Type Channel Quick Connect Single or Reverse Flange Blade Action Parallel Opposed Parallel Opposed Parallel Opposed Application The is a low leakage thermally insulated damper with extruded airfoil blades. features broken blade which minimized the transfer of thermal energy and reduce condensation. It s also IECC (International

More information

Model VCD-20. Control Damper. Application. 3V Blade. Ratings. Flange Options. Size Limitations. Blade Operation. Features and Options

Model VCD-20. Control Damper. Application. 3V Blade. Ratings. Flange Options. Size Limitations. Blade Operation. Features and Options Application The series is a general purpose control damper for applications as an automatic control or manual balancing damper with low to medium pressure and velocity systems. A wide range of electric

More information

FBV-43. Vertical Face & Bypass Control Damper Ultra Low Leakage Aluminum Frame Construction. Application and Design. Size Limitations.

FBV-43. Vertical Face & Bypass Control Damper Ultra Low Leakage Aluminum Frame Construction. Application and Design. Size Limitations. Application and Design The is a vertical style face and bypass low leakage damper. This model is intended for application in medium to high pressure and velocity systems. Smooth profile extruded aluminum

More information

Model VCD-43 Extruded Airfoil Blade Control Damper

Model VCD-43 Extruded Airfoil Blade Control Damper Application and Design The is an extremely low leakage damper designed to meet the highest standards established for commercial control dampers. The is intended for application in medium to high pressure

More information

Thermal Isolation. Break

Thermal Isolation. Break Application and Design The is a low leakage thermally insulated damper with extruded airfoil blades. features thermally broken frame and blade will minimize the transfer of thermal energy and reduces condensation.it

More information

AMD-42-TD. Thermal Dispersion Air Measuring Station with VCD-42 Control Damper. Application and Design. Ratings. Features and Control Options

AMD-42-TD. Thermal Dispersion Air Measuring Station with VCD-42 Control Damper. Application and Design. Ratings. Features and Control Options Application and Design Thermal Dispersion Air Measuring Station with VCD-42 Control Damper The combines the functionality of a highly accurate thermal dispersion airflow measuring station and a low leakage

More information

VCD-43V. Vertical Airfoil Blade Control Damper. Application and Design. Ratings. Size Limitations. Features and Options: Pressure:

VCD-43V. Vertical Airfoil Blade Control Damper. Application and Design. Ratings. Size Limitations. Features and Options: Pressure: Application and Design is a low leakage damper with vertical blade orientation designed to meet the highest standards established for commercial control dampers. The is intended for application in medium

More information

AMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application. Ratings. Features and Options

AMD-23-TD. Thermal Dispersion Air Measuring Station with VCD-23 Control Damper. Application. Ratings. Features and Options Application Thermal Dispersion Air Measuring Station with VCD-23 Control Damper The combines the functionality of a highly accurate thermal dispersion airflow measuring station and a low leakage control

More information

Insulated Control Damper. 12 x 7 (305 x 178) 8 x 7 (203 x 178)

Insulated Control Damper. 12 x 7 (305 x 178) 8 x 7 (203 x 178) R Application and Design The is a low leakage thermally insulated damper with extruded airfoil blades. features thermally broken blade to eliminate the transfer of heat or cold penetration and reduced

More information

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x 305) 5 in. (127mm) Parallel

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x 305) 5 in. (127mm) Parallel Application and Design The is a low leakage thermally insulated damper with extruded airfoil blades. features thermally broken frame and blade to eliminate the transfer of heat or cold penetration and

More information

Model VCD-33. Low Leakage Airfoil CONTROL DAMPER. Flange Options. Blade Operation. Size Limitations

Model VCD-33. Low Leakage Airfoil CONTROL DAMPER. Flange Options. Blade Operation. Size Limitations Application and Design The series is an ultra low leakage damper with rugged steel airfoil blades designed to meet the highest standards established for commercial control dampers. The airfoil shape reduces

More information

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x in. W x 120 in. H (3658mm x 3048mm) 5 in.

Insulated Control Damper. 1/2 in. (13mm) 1/2 in. (13mm) 12 x 12 (305 x 305) 8 x 12 (203 x in. W x 120 in. H (3658mm x 3048mm) 5 in. R Application and Design The is a low leakage thermally insulated damper with extruded airfoil blades. features thermally broken frame and blade to eliminate the transfer of heat or cold penetration and

More information

VCD-23 Low Leakage CONTROL DAMPER

VCD-23 Low Leakage CONTROL DAMPER Application and Design The series is a ruggedly built low leakage control damper intended for application in low to medium pressure and velocity systems. A wide range of electric actuators are available.

More information

Model VCD-18. Ratings. Blade Operation. Size Limitations. Features & Options

Model VCD-18. Ratings. Blade Operation. Size Limitations. Features & Options Application and Design The series is a general purpose, low leakage control damper intended for application in low pressure and velocity systems. atings Pressure: 2 in. wg (.5 kpa) - pressure differential.

More information

Model VCD-20V. 3V Vertical Control Damper. Application and Design. Ratings (See page 4 for specific limitations) Flange Options.

Model VCD-20V. 3V Vertical Control Damper. Application and Design. Ratings (See page 4 for specific limitations) Flange Options. Application and Design The series is a vertical blade general purpose damper for application as an automatic control or manual balancing damper. This model is intended for application in low to medium

More information

Model VCD-20 3V CONTROL DAMPER

Model VCD-20 3V CONTROL DAMPER R Application and Design The series is a ruggedly built general purpose damper for application as an automatic control or manual balancing damper. This model is intended for application in low to medium

More information

Model SMD-302M. Modulating Smoke Damper. Application. Steel Airfoil Blades UL 555S Leakage Class II. Ratings. Size Limitations.

Model SMD-302M. Modulating Smoke Damper. Application. Steel Airfoil Blades UL 555S Leakage Class II. Ratings. Size Limitations. Model Application The is a leakage rated modulating smoke damper with airfoil blades for operational closure in emergency smoke control situations. This model serves the function of both a control damper

More information

HCD-135. Industrial Control Damper. Application and Design. Ratings (see page 2 and 3 for specific limitations) Standard Construction.

HCD-135. Industrial Control Damper. Application and Design. Ratings (see page 2 and 3 for specific limitations) Standard Construction. Application and Design Model is a heavy duty industrial control damper with a flanged frame. It is designed to control airflow and provide shut off in HVAC or industrial process control systems. A variety

More information

Model FSD-211. Application. Combination Fire Smoke Damper Steel 3V Blades UL 555S Leakage Class I UL /2 Hour Fire Resistance Rating.

Model FSD-211. Application. Combination Fire Smoke Damper Steel 3V Blades UL 555S Leakage Class I UL /2 Hour Fire Resistance Rating. Application Model is a combination fire smoke damper with 3V style blades. This model is designed for operation and dynamic closure in emergency fire smoke situations. It is rated for airflow and leakage

More information

Model SMD-301. Smoke Damper Steel Airfoil Blades UL 555S Leakage Class I. Application. Ratings. Size Limitations. Features

Model SMD-301. Smoke Damper Steel Airfoil Blades UL 555S Leakage Class I. Application. Ratings. Size Limitations. Features Model Application The is a leakage rated smoke damper with airfoil blades for operational closure in emergency smoke control situations. This model serves the function of both a control damper and smoke

More information

Model FSD-331. Combination Fire Smoke Dampers. Application. Ratings. Features

Model FSD-331. Combination Fire Smoke Dampers. Application. Ratings. Features Application Model is a high performance combination fire smoke damper with Class I leakage. High strength airfoil blades ensure the lowest resistance to airflow in HVAC systems with velocities to 4000

More information

Model CFSD-211. Corridor Ceiling FIRE SMOKE DAMPER Steel 3V Blades UL 555S Leakage Class I

Model CFSD-211. Corridor Ceiling FIRE SMOKE DAMPER Steel 3V Blades UL 555S Leakage Class I Application and Design Model is a combination fire smoke damper that is UL classified to protect corridor ceiling penetrations as required by the Uniform Building Code. This model s operational ratings

More information

HCD-230 Industrial Control Damper

HCD-230 Industrial Control Damper Application and Design Model is a heavy duty industrial control damper with a flanged frame. It is designed to control airflow and provide shut off in HVAC or industrial process control systems. A variety

More information

Model FSD-331 Combination Fire Smoke Dampers

Model FSD-331 Combination Fire Smoke Dampers R APPLICATION Model is a high performance combination fire smoke damper with class I leakage. High strength airfoil blades ensure the lowest resistance to airflow in HVAC systems with velocities to 4000

More information

SMD-201M. Application. Modulating Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

SMD-201M. Application. Modulating Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations. Application Model is a leakage rated modulating smoke damper with 3V style blades. The has been qualified to 2,000 fpm (10.2 m/s) and 6 in. wg (1.5 kpa) for operational closure in emergency smoke control

More information

SMD-201. Application. Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations.

SMD-201. Application. Smoke Dampers Steel 3V Blades UL 555S Leakage Class I. Ratings. Operational Rating. Size Limitations. Application Model is a leakage rated smoke damper with 3V style blades. The has been qualified to 2,000 fpm (10.2 m/s) and 6 in. wg (1.5 kpa) for operational closure in emergency smoke control situations.

More information

Model DFD-230 Multi-Blade Fire Damper Steel 3V Blades UL555 3 Hour Fire Resistance Rating

Model DFD-230 Multi-Blade Fire Damper Steel 3V Blades UL555 3 Hour Fire Resistance Rating Application Model is a multi-blade fire damper with 3V style blades. The has been qualified to 4000 fpm (20.3 m/s) and 10 in. wg (2.5 kpa) for dynamic closure in emergency fire situations. Model may be

More information

Model SSFSD-211. Combination Fire Smoke Damper 304 Stainless Steel 3V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

Model SSFSD-211. Combination Fire Smoke Damper 304 Stainless Steel 3V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating R Model Application Model is a 304SS combination fire smoke damper with 3V style blades. The is qualified to 2,000 fpm (10.2 m/s) and 6 in. wg (1.5 kpa). This damper may be installed vertically (with blades

More information

Model FSD-211. Combination FIRE SMOKE DAMPERS Steel 3-V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating

Model FSD-211. Combination FIRE SMOKE DAMPERS Steel 3-V Blades UL 555S Leakage Class I UL Hour Fire Resistance Rating R APPLICATION Model FSD-211 is a combination fire smoke damper with 3V style blades. The FSD-211 has been qualified to 2000 fpm (10.2 m/s) and 6 in. wg (1.5 kpa) for operation and dynamic closure in emergency

More information

Model FSD-212. Combination FIRE SMOKE DAMPERS

Model FSD-212. Combination FIRE SMOKE DAMPERS R APPLICATION Model is a combination fire smoke damper with 3V style blades. The has been qualified to 2000 fpm (10.2 m/s) and 6 in. wg (1.5 kpa) for operation and dynamic closure in emergency fire smoke

More information

TED50XT EXTREME TEMPERATURE THERMALLY EFFICIENT, INSULATED BLADE DAMPER

TED50XT EXTREME TEMPERATURE THERMALLY EFFICIENT, INSULATED BLADE DAMPER 3900 Dr. Greaves Rd. Kansas City, MO 64030 (816) 761-7476 FAX (816) 765-8955 APPLICATION Ruskin model TED50XT is a low leak, thermally efficient damper with insulated extruded aluminum blades specially

More information

5995 Greenwood Plaza Blvd. Suite 100 Greenwood Village, CO (fax)

5995 Greenwood Plaza Blvd. Suite 100 Greenwood Village, CO (fax) TO: Legacy Mechanical Inc 1455 So Platte River Dr Denver CO 80223 5995 Greenwood Plaza Blvd. Suite 100 Greenwood Village, CO 80111-4710 303-571-5377 303-629-7467 (fax) PROJECT: JCS - Columbine High School

More information

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile Centrifugal Cabinet s BCF Belt Drive Low-Profile November 204 BCF Centrifugal Cabinet Contents Standard Construction Features... 3 Options and Accessories... 4 Filter and Mixing Box Data... 5 Typical Installations...

More information

Qualified for installation in wood joist ceiling construction. CRD-1WT. Fire Dampers. Model

Qualified for installation in wood joist ceiling construction. CRD-1WT. Fire Dampers. Model Life Safety Products Life Safety Products Life safety dampers are intended to protect openings in walls and/or partitions to prevent the spread of fire and/or smoke. The four types are: Ceiling Radiation

More information

WD-200 Series. Model WD-220 Flange Opposite Motor. Model WD-210 Flange on Motor Side. Model WD-200 No Flange. Motorized Backdraft Damper.

WD-200 Series. Model WD-220 Flange Opposite Motor. Model WD-210 Flange on Motor Side. Model WD-200 No Flange. Motorized Backdraft Damper. Application The WD200 series are electrically motorized backdraft dampers that open when energized and spring return close when deenergized. The WD200 series are for horizontal or vertical mounting. Primary

More information

Tube Axial Inline Fans

Tube Axial Inline Fans Tube Axial Inline Fans Models TDI & TBI-CA Level 3 with Cast Aluminum Propeller Direct & Belt Drive Clean Air or Fume Exhaust July 2011 Features Tube Axial Inline Fans Greenheck s tube axial fans are the

More information

SECTION CONTROL DAMPERS

SECTION CONTROL DAMPERS SECTION 23 09 13.43 - CONTROL DAMPERS PART I - GENERAL 1.1 SECTION INCLUDES A. Airfoil Dampers, Heavy Duty Galvanized Steel B. Thermally Insulated Dampers, Heavy Duty Galvanized Steel C. Airfoil Dampers,

More information

Positive Seal Damper Blades with Vinyl Gaskets 2.5" SERIES 3000 SIDE MOUNT - NO FLANGE ORDERING METHOD FOR BACKDRAFT & MOTORIZED BACKDRAFT DAMPERS

Positive Seal Damper Blades with Vinyl Gaskets 2.5 SERIES 3000 SIDE MOUNT - NO FLANGE ORDERING METHOD FOR BACKDRAFT & MOTORIZED BACKDRAFT DAMPERS BACKDRAFT DAMPERS BLADE OPTION: SR: 0.016-0.020 roll formed aluminum with vinyl gasket - used with fan motors under 1 HP SE: 0.05 extruded aluminum with vinyl gasket - used with fan motors over 1 HP Positive

More information

Installation, Operation, and Maintenance Instructions

Installation, Operation, and Maintenance Instructions Document Number 463384 VCD, FBH & FBV MODELS Vertical and Horizontal Mount Installation, Operation, and Maintenance Instructions This manual is the property of the owner, and is required for future maintenance.

More information

Control Dampers and Fire Dampers. Volume 1 - March Insulated Control Dampers. Non-Insulated Control Dampers. Framing. Accessories.

Control Dampers and Fire Dampers. Volume 1 - March Insulated Control Dampers. Non-Insulated Control Dampers. Framing. Accessories. Insulated Control Dampers 2 Volume 1 - March 2010 6 Non-Insulated Control Dampers 8 Framing Accessories 9 Jack Shaft Steel Control Dampers Fire Dampers 10 11 Control Dampers and Fire Dampers 3900 Insulated

More information

Series HCD Airfoil Control Damper

Series HCD Airfoil Control Damper Series HCD Airfoil Control Damper Model: HCD-1 The Holyoake HCD-1 is a precisely made volume and pressure control device with extremely low leakage when closed, (in the range of 0.003m 3 /s at 100 Pa).

More information

DAMPERS FOR COMMERCIAL & INDUSTRIAL APPLICATIONS IN HEATING, VENTILATING & AIR CONDITIONING

DAMPERS FOR COMMERCIAL & INDUSTRIAL APPLICATIONS IN HEATING, VENTILATING & AIR CONDITIONING PUB. NO. 732-3 DAMPERS FOR COMMERCIAL & INDUSTRIAL APPLICATIONS IN HEATING, VENTILATING & AIR CONDITIONING The most widely used dampers in commercial HVAC applications Control Dampers - Extruded Aluminum

More information

SP Standard Profile. In Duct or Flanged to Duct Install Types OPPOSED ACTION PARALLEL ACTION. Extended Rear Flange Install Type

SP Standard Profile. In Duct or Flanged to Duct Install Types OPPOSED ACTION PARALLEL ACTION. Extended Rear Flange Install Type 1 SUBMITTAL DATA Series 1000 Air-Foil Control Damper SP Standard Profile 2" 50.8 mm In Duct or Flanged to Duct Install Types 4" 101.6 mm 6.4" 162.6 mm blades fully open 1" 25.4 mm Extended Rear Flange

More information

Document number AMS & AMD Damper Series for Honeywell Spyder Controller Installation, Operation, and Maintenance Instructions

Document number AMS & AMD Damper Series for Honeywell Spyder Controller Installation, Operation, and Maintenance Instructions Document number 480938 AMS & AMD Damper Series for Honeywell Spyder Controller Installation, Operation, and Maintenance Instructions Use this manual when AMS and AMD series dampers were purchased prior

More information

BD-1600 Balancing/Zone Control Damper

BD-1600 Balancing/Zone Control Damper BD-1600 Balancing/Zone Control Damper Product Bulletin Code No. LIT-12012355 Issued September 2016 Refer to the QuickLIT website for the most up-to-date version of this document. The BD-1600 Balancing/Zone

More information

WD-300 Series. Backdraft Damper Vertical Mount - Horizontal Airflow. Application and Design. Ratings. Frame Styles. Size Limitations.

WD-300 Series. Backdraft Damper Vertical Mount - Horizontal Airflow. Application and Design. Ratings. Frame Styles. Size Limitations. Application and Design The WD300 series dampers are designed to prevent reverse airflow in horizontal exhaust applications. The WD300 features a pressure sensitive blade design that opens and remains open

More information

Introduction to Johnson Controls Dampers

Introduction to Johnson Controls Dampers Damper and Actuator Product Guide 268.1 Damper Engineering Section Product Bulletin Issue Date 1297 Introduction to Johnson Controls Dampers For over 100 years, Johnson Controls has been the industry leader

More information

Laboratory Exhaust Systems

Laboratory Exhaust Systems Laboratory Exhaust Systems Vektor -HS, Vektor -MS and Vektor -CS with Variable Geometry Nozzle September 017 Vektor -HS, Vektor -MS and Vektor -CS Greenheck s Variable Geometry Nozzle exhaust systems allow

More information

SD-1250 and SD-1600 Series Smoke Dampers

SD-1250 and SD-1600 Series Smoke Dampers SD-1250 and SD-1600 Series Smoke Dampers Product Bulletin Code No. LIT-1201592 Issued January 30, 2014 Supersedes October 14, 2013 Johnson Controls provides a leakage-rated damper for life safety smoke

More information

Air Quality Solutions

Air Quality Solutions Air Quality Solutions Installation & Maintenance Manual Model: IAQ50X Air Measuring Station Indoor Air Quality Damper II-IAQ50X-818/Replaces II-IAQ50X-612 ALL STATED SPECIFICATIONS ARE SUBJECT TO CHANGE

More information

FOR USE IN SOLUTION AIR HANDLING UNITS

FOR USE IN SOLUTION AIR HANDLING UNITS AMS-60 AIRFLOW MONITORING DEVICE APPLICATION GUIDE Supersedes: NOTHING Form 102.20-AG1 (303) FOR USE IN SOLUTION AIR HANDLING UNITS GENERAL The YORK AMS-60 is an airflow monitoring device which combines

More information

Laboratory Exhaust Systems

Laboratory Exhaust Systems Laboratory Exhaust Systems Vektor -MH and Vektor -MD Mixed Flow High Plume and High Plume Dilution Blower August 2013 Vektor-MH High Plume and High Plume Dilution Blower Greenheck s Vektor-MH high plume

More information

Laboratory Exhaust Systems

Laboratory Exhaust Systems Laboratory Exhaust Systems Vektor -CH and Vektor -CD Centrifugal High Plume and High Plume Dilution Exhaust System July 2015 Vektor-CH High Plume and Vektor-CD High Plume Dilution Exhaust System Greenheck

More information

CONTROL DAMPERS. Models 1810 & Model Model Model 1370

CONTROL DAMPERS. Models 1810 & Model Model Model 1370 CONTROL DAMPERS CONTROL DAMPERS MODELS 1810 & 1820 MANUAL ALANCING DAMPERS STEEL Models 1810 and 1820 have been engineering and designed for manual balancing applications in low to medium pressure and

More information

Life Safety Dampers. Fire Combination Fire Smoke Smoke Ceiling Radiation

Life Safety Dampers. Fire Combination Fire Smoke Smoke Ceiling Radiation Life Safety Fire Combination Fire Smoke Smoke Ceiling Radiation June 2018 Table of Contents Introduction......................................... 3- Fire....................................... 5-19 Application...................................................

More information

AMCA MEMBER. American Warming and Ventilating. A Mestek Company. Quality Air Control Dampers

AMCA MEMBER. American Warming and Ventilating. A Mestek Company. Quality Air Control Dampers AMCA MEMBER American Warming and Ventilating A Mestek Company Quality Air Control Dampers Over a century of dedication to quality products and customer satisfaction has enabled American Warming and Ventilating

More information

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved Centrifugal Roof Supply Fans Models and Forward Curved April 2008 Centrifugal Filtered Roof Supply Fan When you buy a Greenheck model or, you receive a fan with the industry s best performance and durability

More information

Centrifugal Cabinet Fans Model BCF Belt Drive Low-Profile

Centrifugal Cabinet Fans Model BCF Belt Drive Low-Profile Centrifugal Cabinet s BCF Belt Drive Low-Profile May 2007 BCF Belt Drive Cabinet s Greenheck belt drive low-profile cabinet fans, BCF, are designed for efficiency and reliability in supply, exhaust or

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Document 461338 SMOKE DAMPERS SMD-XXX, SMD-XXXEF, SMD-XXXM, SMD-XXXV, SESMD-XXX, SSSMD-XXX, SMDR-XXX, SESMDR-XXX, and SSSMDR-XXX Series Leakage Rated Smoke Dampers Vertical and Horizontal Mount Installation,

More information

Mancoolers Models MCY, MCB, MCP

Mancoolers Models MCY, MCB, MCP Mancoolers s MCY, MCB, MCP October 2007 Mancoolers Greenheck MC Mancooler fans are direct drive, tube axial fans designed for applications where localized air direction and circulation are required. Mancoolers

More information

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved Centrifugal Roof Supply Fans Models and Forward Curved B U I L D I N G V A L U E I N A I R. April 2008 Centrifugal Filtered Roof Supply Fan When you buy a Greenheck model or, you receive a fan with the

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Document 483509 VCD, FBH & FBV Models Vertical and Horizontal Mount Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting

More information

Sidewall Propeller Fans Direct Drive. Exhaust / Supply

Sidewall Propeller Fans Direct Drive. Exhaust / Supply Sidewall Propeller Fans Direct Drive / February 2009 Sidewall Propeller Fans Greenheck s sidewall propeller fan line is the ideal choice for factory and warehouse applications where high volumes of air

More information

AD-1250 Airflow Measuring Station

AD-1250 Airflow Measuring Station AD-1250 Airflow Measuring Station Product Bulletin Code No. LIT-12011472 Issued March 2016 Refer to the QuickLIT website for the most up-to-date version of this document. The AD-1250 Airflow Measuring

More information

Centrifugal Inline Fans Models SQ-M and BSQ-M. Direct and Belt Drive

Centrifugal Inline Fans Models SQ-M and BSQ-M. Direct and Belt Drive Centrifugal Inline s Models SQ-M and BSQ-M Direct and Belt Drive July 2010 Centrifugal Inline Duct s Greenheck's model SQ-M and BSQ-M centrifugal square inline fans feature a unique combination of installation

More information

ARROW INDUSTRIAL PRODUCTS

ARROW INDUSTRIAL PRODUCTS IP-2R ARROW INDUSTRIAL PRODUCTS For Applications in Industrial, Power Plant & Commercial Projects ARROW UNITED INDUSTRIES ARROW UNITED INDUSTRIES has specialized in the manufacturing of air control products

More information

LOW LEAKAGE VOLUME CONTROL DAMPER

LOW LEAKAGE VOLUME CONTROL DAMPER LOW LEAKAGE VOLUME CONTROL DAMPER On Time Delivery According to Standard Customization Quality Cooperation LOW LEAKAGE VCD CATALOG REV 00 APRIL 2018 2017_04_08 ABOUT US Sharqawi Air distribution systems

More information

Dimensional Data Curb Optional Glass Damper Hood. A B C Size (O.D.) Size (O.D.) Qty Size Actuator Qty

Dimensional Data Curb Optional Glass Damper Hood. A B C Size (O.D.) Size (O.D.) Qty Size Actuator Qty Submittal Data Model PELV-100 Penthouse Elevator Vented Hood Application and Design The PELV-100 Penthouse Elevator Vented Hood is a gravity ventilator penthouse with an 18" x 18" gasketed access door

More information

FSD36, FSD36LP COMBINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 2

FSD36, FSD36LP COMBINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 2 3900 Dr. Greaves Rd. Kansas City, MO 64030 (816) 761-7476 FAX (816) 765-8955 FSD36, FSD36LP COMINATION FIRE AND SMOKE DAMPER 1 1 /2 HOUR UL555 RATED, UL555S LEAKAGE CLASS 2 APPLICATION Ruskin FSD36 Series

More information

FSD60, FSD60LP CoMBINAtIoN FIRe AND SMoKe DAMPeR

FSD60, FSD60LP CoMBINAtIoN FIRe AND SMoKe DAMPeR 3900 Dr. Greaves Rd. Kansas City, MO 64030 (816) 761-7476 FAX (816) 765-8955 FSD60, FSD60LP CoMINAtIoN FIRe AND SMoKe DAMPeR 1 1 /2 HoUR UL555 RAteD, UL555S LeAKAge CLASS 1 APPLICAtIoN Ruskin FSD60 Series

More information

Centrifugal Cabinet Fans Model BDF. Belt Drive Duct Fan

Centrifugal Cabinet Fans Model BDF. Belt Drive Duct Fan Centrifugal Cabinet s BDF Belt Drive Duct July 007 BDF Belt Drive Duct s Greenheck s Belt Drive Duct s, BDF, provide the industry s best performance and durability. BDF is carefully engineered for efficiency

More information

ID-141x 12-Gauge Hat Channel Industrial Damper

ID-141x 12-Gauge Hat Channel Industrial Damper ID-141x 12-Gauge Hat Channel Industrial Damper Product Bulletin Code No. LIT-12011355 Issued June 12, 2013 Supersedes March 13, 2012 Since 1905, Johnson Controls has developed and refined air control products

More information

B. Fabricate in accordance with ASHRAE handbooks and SMACNA duct manuals. A. Submit in accordance with Division-1 and Section

B. Fabricate in accordance with ASHRAE handbooks and SMACNA duct manuals. A. Submit in accordance with Division-1 and Section SECTION 15910 DUCT ACCESSORIES PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of Contract including General and Supplementary Conditions, Division-1 Specification Sections,

More information

High Performance Axial Fans

High Performance Axial Fans High Performance Axial Fans Model RA Standard and High Temperature High Efficiencies Low Sound January 2014 High Performance Axial Fans Greenheck s model RA, high performance, direct-driven axial fans,

More information

CFSD Series. Product Description

CFSD Series. Product Description COMBINATION FIRE AND SMOKE DAMPER 1-1/2 HR LEAKAGE RESISTANCE CLASS II 250 O F FILE NO: R22165 Product Description Combination Fire / Smoke dampers provide an automatic means of localizing areas of smoke

More information

MOTORIZED VOLUME DAMPER

MOTORIZED VOLUME DAMPER MOTORIZED VOLUME DAMPER 1 a perfect partner in performance... Our Product Ranges Dampers 1 Fire Dampers 2 Fire / Smoke Dampers 3 Volume Control Dampers 4 Motorized Control Dampers 5 Pressure Relief Dampers

More information

VOLUME CONTROL & SHUT OFF DAMPERS SERIES 400

VOLUME CONTROL & SHUT OFF DAMPERS SERIES 400 SERIES 400 Series 900 Volume Control And Shut Off Dampers: Series 900 balancing and shut off dampers have been designed, engineered and tested, with smooth efficient operation as an important consideration.

More information

SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS

SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS SMOKE DAMPERS 96 97 SD SERIES SD for Use in Dynamic Systems Types Galvanized Steel Construction as Standard.. Sleeve Type, Model: SD - 0-00. Circular Type, Model: SD - 50-00. Oval Type, Model: SD - 60-00

More information

CONTROL DAMPERS. Model Model 1370CB. Model 1380CB. Model 1390CB B7

CONTROL DAMPERS. Model Model 1370CB. Model 1380CB. Model 1390CB B7 CONTROL DAMPERS MODEL 1380 HIGH PERFORMANCE ACKDRAFT DAMPER EXTRUDED ALUMINUM HEAVY DUTY Model 1380 is a high performance extruded aluminum gravity operated backdraft damper for use in medium to heavy

More information

RD-2000 Round Control Dampers

RD-2000 Round Control Dampers RD-000 Round Control Dampers Product Bulletin Code No. LIT-8105 Issued February 5, 010 Supersedes July, 009 Johnson Controls provides top-quality, low-leakage RD-000 Round Control Dampers for use in Heating,

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Installation, Operation and Maintenance Manual Document 483514 SMOKE DAMPERS SMD-XXX and SMDR-XXX Series Leakage Rated Smoke Dampers Vertical and Horizontal Mount Please read and save these instructions

More information

Centrifugal Inline Fans

Centrifugal Inline Fans Centrifugal Inline Fans Models SQ-M and SQ-M Direct and elt Drive UILDING VLUE IN IR. February January 2018 2017 Models SQ-M & SQ-M Centrifugal Square Inline Duct Fans Designed for indoor and outdoor clean

More information

Product Data. Features/Benefits. 35K Bypass Terminal. 110 to 4400 cfm

Product Data. Features/Benefits. 35K Bypass Terminal. 110 to 4400 cfm Product Data 35K Bypass Terminal 110 to 4400 cfm Carrier s 35K Series bypass terminals offer: 20-gage, galvanized steel casing construction 1/2-in. thick, dual density fiberglass insulation meeting NFPA

More information

CCS Zone/Bypass Damper Assembly

CCS Zone/Bypass Damper Assembly Code No. LIT-1900539 Issued July 15, 2011 UZR-xx-x, UBR-xx-x, UZD-0xxX0xx-x, UBD-0xxX0xx-x CCS Zone/Bypass Damper Assembly Description The Commercial Comfort System (CCS) Zone/Bypass Damper are zone control

More information

Propeller Hooded Roof Fans

Propeller Hooded Roof Fans Propeller Hooded Roof Fans Series A - Model AE and AS Exhaust and Supply Fans August 8 Model AE and AS Propeller Fans Greenheck s models AE (axial exhaust) and AS (axial supply) spun aluminum direct drive

More information

SafidDampers SPK Standard Construction SPK Description SPK ( Flange Type )

SafidDampers SPK Standard Construction SPK Description SPK ( Flange Type ) ( Flange Type ) SPK 30-100 Standard Construction FRAME: 160mm x 30mm x 1.5mm (16 Ga.) galvanized steel formed channel for flange connection. BLADES: 250mm max. width, 1.5mm (16 Ga.) galvanized steel. FINISH:

More information