ALLOY 825 SHEATHED, MINERAL INSULATED, FIRE-RATED WIRING CABLE

Similar documents
COPPER SHEATHED, MINERAL INSULATED FIRE-RATED WIRING CABLE

MI Heating Cable. HDPE jacketed, copper sheathed MI cable. For surface snow melting in concrete, asphalt, and pavers. MI Heating Cable Configuration

XMI-L STAINLESS STEEL, LOW TEMPERATURE SHEATH CONSTANT WATTAGE MINERAL INSULATED HEATING CABLES

Product Overview. Application

QUICKTERM TERMINATION KIT

STAINLESS STEEL, LOW TEMPERATURE SHEATH CONSTANT WATTAGE MINERAL INSULATED HEATING CABLES

MI HEATING CABLE COPPER AND HDPE JACKETED COPPER SHEATHED MI CABLE. For commercial and industrial applications. Heating cable construction

MI HEATING CABLE COPPER AND HDPE JACKETED COPPER SHEATHED MI CABLE. For heat loss replacement, floor heating and radiant space heating

Power-Limiting Cables

Heating Cable. Construction

SPC-P Smart Power Connection with Temperature Monitoring Transmitter Pipe Mounted Installation Instructions

C A HEATING CABLE GLAND KIT INSTALLATION INSTRUCTIONS

Thermocouples W A T L O W

Heating Cable. Construction

Corflex. Continuous Corrugated Aluminum Sheathed PL, MC and MV Industrial Cables. Introduction Applications... 3

Mineral Insulated Resistance Thermometers (RTD)

EMK-XP ElectroMelt Power Connection and End Seal Kit Installation Instructions

CIVACON GROUND VERIFICATION RACK MONITOR SYSTEM and ASSOCIATED EQUIPMENT

C A Heating Cable Gland Kit Installation Instructions

PVC SHEATH FLAME RETARDANT CABLE TO IEC60332

HPS EnduraCoil. Cast Resin Transformer

JBS-100-STB Single Entry Power Connection with Junction Box Installation Instructions

FR-3S Fire Resistant Cables

C-L-X Aluminum Sheath Type IEC

600/1000V XLPE Insulated, LSZH Sheathed, Armoured Power Cables (2-5 Cores)

PROBABLY THE BEST FLEXIBLE BAR IN THE WORLD

PRODUCTS COMMERCIAL BUILDING WIRE & CABLE

Tubeskin thermocouple assembly Model TC59-W

Battery Performance Specifications

SEALSAFE PRODUCTS CONDUIT AND CABLE PRODUCTS. for HARSH AND HAZARDOUS ENVIRONMENTS. Certificate ANZEx

Pyrohalon. Cables, halogen-free, fire-retardant. Pyrohalon PLUS Fire-resistant cables, halogen-free, fire-retardant

JBM-100-STB NEMA 4X-rated connection kit Installation Instructions

MIQ MINERAL INSULATED HEATING CABLE INSTALLATION INSTRUCTIONS

Control switch/load disconnect switch Series 8008

600/1000V XLPE Insulated, PVC Sheathed, Armoured Power Cables (2-5 Cores)

MC122IG 12/2 WG MC Solid-Isolated Ground, Steel Armor. Features. Material, Color, and Finish. Dimensions and Weight.

BS6724 SWA/LSZH Cable IEC /1000V

XMI Mineral Insulated Heating Cables

Introduction. Nexans wire and cable. Contact us for all your wire and cable needs

AccuTru ExL Furnace Tubeskin Thermocouples

Insulation Colours: Orange (Standard) Natural Natural. Sheath Colours: Orange (Standard) Orange (Standard) Bedding: Black

Technical Data Sheet Unshielded (YY) PVC Control Cable

Explosion-proof Solenoids ATEX. II 2 G / II 2 D EEx dm IIC T4, T5, T6. Catalogue 8735/GB. Maximum photo

Load and Motor Switches, Load-Break Switches Series 8549

Generator Set Applications FT-10 Network Control Communications Module (CCM-G) Kit

PRODUCT INFORMATION MULTI-STANDARD SC 2.1. U.I. Lapp GmbH

Gexol. Gexol. World Class Oil & Gas Cables. The Global Cable Solutions Company


Engineering Information. Solenoid Valves Principles of Operation. Solenoid Valves. Direct Acting Valves (Figures 1A, 1B)

SECTORFLEX CABLE CATALOGUE

Compact temperature switch Model TCS

ÖLFLEX CLASSIC 110 H Info Benefits

Hot Runner Thermocouples Model TC46

ARMOR-GRIP Suspension: Double

GMS8/GDS8/GHS8 Multi-Position, Multi-Speed Gas Furnaces

JBS-100-A, A6 SINGLE ENTRY POWER CONNECTION WITH JUNCTION BOX INSTALLATION INSTRUCTIONS

Quick Connection Panel (QCP) Installation Guide

PROTEC. Screened Wiring Cable. Updated to meet new requirements of BS 8436:2011 BASEC approved.

NEC 2011 Code Changes

Easier! Faster! Safer!

SPECIFICATION S VR 1(4) HALOGEN FREE POWER AND CONTROL CABLE FOR MARINE APPLICATIONS LM-HF 0,6/1 kv and TEMAR PHFX-U 0,6/1 kv APPLICATI

GTZ 25 / 40 / 55. TECHNICAL DATA General features. Category of use: AC51, AC53a

grounded in service wired to innovate STABILOY Type XHHW-2 and USE-2/RHH/RHW-2

2016 Photovoltaic Solar System Plan Review List

LBD-Series. Radiator-Cooled Load Bank. Description

Compact pressure switch Model PCS

Unarmoured Single-Core Cables to BS6883

Control Cable Type T/N 600/1000 volts DRILMAR 90 Polyvinyl Chloride/Nylon Insulated Drilling Rig and Marine Cable

ÖLFLEX CLASSIC 135 CH -halogen-free control cable, HFFR, flexible and screened for various applications, U 0 /U: 300/500V

PDU Input Power Cord. Before installation. Specifications

N2XSEFGbY 3 x (25-300) mm² 3.6/6 kv

Tubeskin thermocouple assembly Model TC59-V

CORFLEX. Continuous Corrugated and Welded, Impervious Aluminum Sheathed PL, MC and VFD Industrial Cables. Introduction Applications...

Variable Frequency Drive (VFD) Cable Solutions

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

SPECIAL CABLES TEMPERATURE MEASUREMENT HARNESSING S ULTRA CONTINUOUSLY FLEXIBLE WITH HIGHEST FIRE PROTECTION

Cable resistance thermometer Model TR40

A LOOK INSIDE MODEL 7 TECHNOLOGY IN ACTION 70 Series LEVERLESS LIMIT SWITCH GO Switch 70 Series end sensing switches use three permanent magnets and p

Type MMV-WP Medium Voltage Wind Power Cable

DC400 Dispensing Cutoff System

Compact differential pressure switch Models DC, DCC

NEC 2014 Code Changes

POWER GENERATION SWITCH RATED ELECTRICAL CONNECTORS FOR INDUSTRY. hyconelec.co.za MARECHAL TECHNOLOGY

AMENDMENT ELECTRIC SERVICE MANUAL 2014

Sub-D Connector. Concentrated wiringd Connector for Manifold type. Lead-Out Direction of cable is selectable. Suitable for PISCO's Solenoid Valves.

LSZH Fire Resistant Cables

600/1000V XLPE Insulated PVC Sheathed Power Cables (Multicore)

TYPE 7700D/7700W DOUBLE OPPOSED CARTRIDGE MIXER SEAL

Load and Motor Switches, Load-Break Switches Series 8544

Figure 1 Figure 2 Double Acting Actuator Spring Return Actuator

M High Performance Power Transmission Couplings

Section 3 Index Furnace Tube Skin Thermocouples

PERFORMANCE SPECIFICATIONS

Easy-to-Install General-Purpose Cartridge Seal EZ-1

SHIELD-FLEX EMI / RFI Shielded Conduit

254 Series Convector. Standard Construction Features

METAL BELLOWS CARTRIDGE SEAL. Operating Conditions

Technical Data Sheet Unshielded (YY) PVC Control Cable

Convector. Standard Construction Features

FR-N1X1G1. Low voltage - Energy, cabling, signalling and control

Transcription:

PYOTENAX SYSTEM 2000 ALLOY 825 SHEATHED, MINEAL INSULATED, FIE-ATED IING CALE Cable construction Seamless Alloy 825 metal sheath Magnesium oxide (MgO) insulation Solid nickel-clad copper conductors PODUCT OVEVIE Pyrotenax fire-rated mineral insulated (MI) wiring cables facilitate the controlled shutdown of critical processes and systems in the event of a hydrocarbon flash fire in both nonhazardous and hazardous locations. Using the electrical test procedure described in UL2196, System 2000 MI cable maintains electrical circuit integrity for 30 minutes during exposure to the UL 1709 fire test. The UL 1709 test, referenced in API 2218, replicates an intense hydrocarbon fire, reaching 2000 F (1093 C) in 5 minutes when subjected to a heat flux of 65,000 TU/ft2 hr (200 k/ m2) in an enclosed furnace. System 2000 wiring cable is constructed with an Alloy 825 sheath and nickel-clad copper conductors that allow continuous exposure temperatures to 1238 F (670 C) and withstand rapid-rise temperature excursions to 2000 F (1093 C). In addition, the sheath provides durability in areas where corrosives may be present and the nickel-clad copper conductors permit higher current ratings compared with nickel conductors. MI cable is made of inorganic materials and provides zero smoke generation, zero fuel contribution, and zero flame spread. Highly compacted MgO insulation prevents the flow and transmission of explosive gases through the wiring cables. System 2000 MI cable may be used for power, control, and communication wiring in the following environments: Petrochemical to protect critical systems in the event of a hydrocarbon flash fire Petrochemical and mining in hazardous areas to provide a gas path block Manufacturing in areas of extreme heat, around furnaces, etc. Tunnels and confined spaces MI cables do not burn; no smoke generated Nuclear and fossil fuel power generation plants for wiring to equipment where heat or radiation may be of concern Pulp and paper where corrosives are present 1 / 5

System 2000 wiring cable is typically supplied as a factory-assembled Duoterm unit complete with terminations at each end, allowing for immediate installation in the field. In hazardous areas, the simplified installation of MI cable means that conduit systems and explosion proof seals are not required; simply connect the cable directly to the equipment or junction box. Pyrotenax System 2000 meets the requirements of national electrical codes. For additional information on factory-assembled Duoterm units or bulk cable and field installed terminations, contact your Pentair Industrial Heat Tracing Solutions representative or call (800) 545-6258. CALE CONSTUCTION Sheath Alloy 825 Insulation Magnesium oxide (MgO) Conductor type Nickel-clad copper Insulation voltage rating 600 V Conductor size 16 AG 2 AG (Physical conductor size is larger due to nickel cladding; see Table below) Number of conductors 1, 2, 3, 4, or 7 standard (Contact Pentair Industrial Heat Tracing Solutions for custom configurations) CALE TEMPEATUE ATING Continuous exposure temperature Maximum exposure temperature 1238 F (670 C) 2000 F (1093 C) Typical factory-terminated Duoterm wiring cable unit Epoxy to metal seal Tail A Gland fitting Tail 12 in (300 mm) tails ire cable route length Overall length 12 in (300 mm) tails TEMINATION CONSTUCTION Gland fitting Stainless steel Potting material Epoxy resin Tails Standard tail length 12 in (300 mm) (Please specify if longer tail lengths are required) Maximum exposure temperature 1 Nonhazardous Hazardous High temperature insulated 248 F (120 C); 392 F (200 C) optional 248 F (120 C); 302 F (150 C) optional stranded wire PVC sleeving 220 F (105 C) 220 F (105 C) Size 2 16 AG - 1 AG 1 For factory-assembled Duoterm units, high temperature insulated stranded wire tails are standard unless otherwise noted in table below. For field installed terminations, solid wire tails with PVC sleeving is standard. 2 For field installed terminations, tail size is the same size as the physical conductor size (see Table below). Arrangement of tails at one end Standard Tail Color Code O r Y l l lack Y Yellow hite r rown ed O Orange l lue 2 / 5 EN-PyrotenaxSystem2000-DS-H57049 09/15 INDUSTIAL HEAT TACING SOLUTIONS

600 V IING CALE SPECIFICATIONS Cable reference number Conductor size (AG) Allowable ampacity NEC 75 C/90 C (A) Allowable ampacity CEC, 75 C/90 C (A) Nominal coil length3 [ft / (m)] Nominal weight [lb/1000 ft / (kg/km)] NPT gland size (in) Physical conductor size (AG) Single conductor 253-14 / 1NC825 14 7 30 / 35 30 / 35 1967 / (600) 111 / (165) 1/2 13 286-12 / 1NC825 12 7 35 / 40 35 / 40 1547 / (471) 146 / (217) 1/2 11 319-10 / 1NC825 10 7 50 / 55 50 / 55 1253 / (382) 189 / (281) 1/2 9 355-8 / 1NC825 8 70 / 80 70 / 80 1018 / (310) 241 / (359) 1/2 7 387-6 / 1NC825 6 95 / 105 95 / 105 868 / (265) 306 / (455) 1/2 5 434-4 / 1NC825 4 4 125 / 140 125 / 140 700 / (213) 409 / (609) 3/4 3 480-3 / 1NC825 3 5 145 / 165 145 / 165 574 / (175) 505 / (751) 3/4 2 527-2 / 1NC825 2 5 170 / 190 170 / 190 477 / (146) 615 / (915) 3/4 1 Two conductor 418-14 / 2NC825 14 7 20 / 25 20 / 25 718 / (219) 297 / (442) 3/4 13 465-12 / 2NC825 12 7 25 / 30 25 / 30 582 / (177) 376 / (559) 3/4 11 527-10 / 2NC825 10 7 35 / 40 35 / 40 455 / (139) 493 / (733) 3/4 9 590-8 / 2NC825 8 50 / 55 50 / 55 364 / (111) 631 / (939) 1 7 Three conductor 418-16 / 3NC825 16 / 18 / 718 / (219) 296 / (440) 3/4 15 465-14 / 3NC825 14 7 20 / 25 20 / 25 581 / (177) 374 / (556) 3/4 13 496-12 / 3NC825 12 7 25 / 30 25 / 30 515 / (157) 441 / (656) 3/4 11 543-10 / 3NC825 10 7 35 / 40 35 / 40 431 / (132) 543 / (808) 3/4 9 637-8 / 3NC825 8 50 / 55 50 / 55 316 / (96) 768 /(1145) 1 7 Four conductor 496-14 / 4NC825 14 7 20 6 / 25 6 20 6 / 25 6 512 / (156) 432 / (643) 3/4 13 527-12 / 4NC825 12 7 25 6 / 30 6 25 6 / 30 6 457 / (139) 505 / (751) 3/4 11 590-10 / 4NC825 10 7 35 6 / 40 6 35 6 / 40 6 367 / (112) 651 / (969) 1 9 684-8 / 4NC825 8 50 6 / 55 6 50 6 / 55 6 274 / (84) 901 /(1341) 1 7 Seven conductor 590-14 / 7NC825 14 7 20 6 / 25 6 20 6 / 25 6 364 / (111) 629 / (936) 1 13 637-12 / 7NC825 12 7 25 6 / 30 6 25 6 / 30 6 315 / (96) 760 /(1131) 1 11 3 For longer lengths, please contact Pentair Industrial Heat Tracing Solutions. 4 For factory assembled Duoterm units, tail is stranded wire with PVC sleeving. 5 For factory assembled Duoterm units, tail is solid wire with PVC sleeving and is same size as Physical conductor size. 6 ased on 3 conductors supplying current to the load; other conductor(s) used as neutral or for control signal. Derating factors apply if 4 or more conductors are used as current-carrying conductors. 7 For 14 AG, 12 AG and 10 AG, refer to appropriate sections of NEC and CEC governing conductor overcurrent protection limitations. Note: To obtain cable diameter: use first three digits in the cable reference number and move decimal point three places to the left; result is cable diameter in inches. Example: cable reference 637-12/7NC825 is 0.637" diameter. 3 / 5

APPOVALS ulk Cable Factory-Assembled Duoterm Units and Field Installed Termination Kits Hazardous Locations Class I, Div. 1 and 2, Groups A,, C, D Class II, Div. 1 and 2, Groups E, F, G Class III, Div. 1 and 2 Hazardous Locations Class I, Div. 1 and 2, Groups A,, C, D Class II, Div. 1 and 2, Groups E, F, G Class III, Div. 1 and 2 American ureau of Shipping Type Approved American ureau of Shipping Type Approved Additional Performance Information for MI Cable Passes IEC 60331 flame test modified to 1100 C (2000 F) for 3 hours (normally 750 C or 830 C) with mechanical shock every 5 minutes. Passes customer specified rapid rise open flame test for 45 minutes at 1100 C (2000 F). Note: Caution should be exercised when comparing open flame tests with enclosed furnace tests as the heat flux conditions are very different. 4 / 5 EN-PyrotenaxSystem2000-DS-H57049 09/15 INDUSTIAL HEAT TACING SOLUTIONS

.PENTAITHEMAL.COM NOTH AMEICA Tel: +1.800.545.6258 Fax: +1.800.527.5703 Tel: +1.650.216.1526 Fax: +1.650.474.7711 EUOPE, MIDDLE EAST, AFICA Tel: +32.16.213.511 Fax: +32.16.213.603 ASIA PACIFIC Tel: +86.21.2412.1688 Fax: +86.21.5426.2917 cn. LATIN AMEICA Tel: +1.713.868.4800 Fax: +1.713.868.2333 Pentair, Pyrotenax, System 2000, and Duoterm are owned by Pentair or its global affiliates. All other trademarks are the property of their respective owners. Pentair reserves the right to change specifications without prior notice. 2002 2015 Pentair. 5 / 5