ELECTRIC ACTUATOR AND CONTROLLER FOR AKRON BUTTERFLY VALVES INSTALLATION INSTRUCTIONS

Similar documents
STYLE 3462 FORESTRY BUMPER MONITOR INSTALLATION, OPERATING and MAINTENANCE INSTRUCTIONS

( Versions Available)

STYLE 5148 MERCURYMASTER OSCILLATING NOZZLE INSTALLATION, OPERATING, AND MAINTENANCE INSTRUCTIONS

STYLE 5148 MERCURYMASTER OSCILLATING NOZZLE INSTALLATION, OPERATING, AND MAINTENANCE INSTRUCTIONS

STYLE 3463 FireFox. With Position Feedback Potentiometer

: 1250 gpm in the deck mode : 800 gpm while operating in the ground base - Dual Inlet : 1000 gpm while operating in the ground base - Single Inlet

STYLE 3491 Severe Duty Electric Mining Water Cannon INSTALLATION, AND OPERATING INSTRUCTIONS

The following is intended to provide the basic instructions for installation, operating and maintenance of the Severe Duty Monitor.

Severe Duty Water Cannon Styles 3491 & 3492 Electric & Hydraulic

Severe Duty Water Cannon Styles 3491 & 3492 Electric & Hydraulic

STYLE 3440 DECKMASTER ELECTRIC MONITOR INSTALLATION, OPERATING, AND MAINTENANCE INSTRUCTIONS

STYLE 624, 638 QUICK-ATTACK FOAM TUBE INSTALLATION, OPERATING, AND MAINTENANCE INSTRUCTIONS

STYLE 9300 FLOW/PRESSURE METER INSTALLATION & OPERATING INSTRUCTIONS

3061, 3096, 3126 foam systems gpm Installation Instructions

STYLE 3440 DECKMASTER ELECTRIC MONITOR WITH POSITION FEEDBACK INSTALLATION, OPERATING, AND MAINTENANCE INSTRUCTIONS

Maximum Flow: 600 GPM (3800 LPM) Portable Base 1250 GPM (4800 LPM) Direct Mount. Maximum Pressure: 200 PSI (1380 Kpa, 13.8 BARS)

Product Ratings Electrical Specifications

3061, 3096, 3126 FOAM SYSTEMS GPM INSTALLATION INSTRUCTIONS

BC Brake Caliper. (i) MEX (55) QRO (442) MTY (81) DIST. AUTORIZADO

USER MANUAL. NEMA 48C Flange Mounted, Enclosed, Clutch Brake. FMCBE Model 500 FORM NO. L A (i)

DAP-625S and DAP-875S

Elgin Hydraulic Clutch-Brake ECB-240, Product Number FORM NO. L F FORM NO. L F-0704

150 PSI ILLUMINATED DASH PANEL GAUGE KIT

Amarr SuperFlex. Installation Instructions and Owner's Manual. Entrematic 165 Carriage Court Winston Salem, NC

Watts Series CSM-91. Grooved/Flanged Flow Measurement/Balancing Valves. Installation and Operating Instructions. Table of Contents. 1.

EZ-IN Series Turbine Flowmeter

Single Post Caliper Brake VC500

Ford Mustang Rear Decklid Spoiler Kit. Installation Instructions

Spring-Engaged/Hydraulically-Released BD Caliper Brake. (i) MTY (81) QRO (442) MEX (55)

Web Volume Control Model WV220

2013 Mustang Chin Splitter

DeZURIK 2 20" BOS BUTTERFLY VALVES

ROUSH FUEL SYSTEM UPGRADE CURRENT FORD MUSTANG 5.0L

3061, 3096, 3126 foam systems gpm Installation Instructions

Straight-Bore Clutch LSCC-32, 44, 54

Easytork Solenoid Valve IOM

Mustang Billet Aluminum Pedal Cover Kit P/N R (Manual) and R (Automatic) Installation Instructions

MEX (55) QRO (442) Web Controls

Single Leg AM / CM 20, 24 and 30. Installation

LUBRICATOR GUN INSTRUCTIONS-PARTS LIST. 10,000 psi (700 bar) Maximum Delivery Pressure. Detachable-type

ONBOARD AIR HOOKUP KIT

UNIVERSAL CUSTOMIZABLE MUD FLAP INSTALLATION INSTRUCTIONS

PPM EO-100 TM. Operation Manual

MG12K24T60V4 Mechanical Grapple

Installation & Operators Manual

Pro Shot Grease Dispense Valve

Mustang Billet Rear Lower Control Arm Kit

HIPSTER'S ALUMINUM POWERGLIDE TRANSBRAKE (P/N: 12748A) CAUTION

Giant Hydraulic Disc Brake System

Single-Position Detent Clutch DC Series. (i) MTY (81) MEX (55) QRO (442)

Model HPX60 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

OPW Installation and Maintenance Instructions OPW Series Primary and Secondary Bucket Replacement Instructions

Attachment Solutions. Superlift System. Operators Manual

FCB-450, LCB-600, MCB-800

Users Manual Certified Series Direct Drive Pump 1-7 LPM

Liquid Turbine Flowmeter

Owner s Manual & Safety Instructions

GETZ EQUIPMENT INNOVATORS PART NO.: 3G59419 MODEL: BV 101 P PNEUMATIC BELT VISE WITH EXTENDED BELT & ROLLER

HALLMARK INDUSTRIES INC

DCD Dual Cartridge Dispenser Operation Manual

Two-way cable interlock kit for Magnum fixed circuit breakers

A Member of the. Integrated Metering Technologies

ROUSH Front Splitter Kit

RT404-FLEX II ROTARY TABLE OPERATING MANUAL

IV STANDS. Assembly, Usage and Maintenance INSTRUCTION MANUAL

INSTRUCTIONS AND SERVICE MANUAL WITH PARTS LIST

Through-Shaft Clutch-Brake LSCB-32HT, LSCB-32HT, LSCB-44, LSCB-44HT, LSCB-54HT FORM NO. L D-0606 MEX (55) QRO (442)

A Member of the. Integrated Metering Technologies

HBC-20 - LED HIGH BAY

MODEL 5120 Tire Repair Station

Model NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

Before installing your Roush Performance Product(s), read through the entire installation procedure and check to make sure all items are present.

Before installing your Roush Performance Product(s), read through the entire installation procedure and check to make sure all items are present.

ROUSH Short Throw Shifter Kit

Installation Instructions

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

22004 INSTALLATION INSTRUCTIONS INSTALLATION 07-UP JEEP JK 2/4 DOOR REAR COILOVER CONVERSION SYSTEM COMPONENTS INCLUDED HARDWARE INCLUDED

Interior Digital Load Scale 202-DDG-01. Installation and Operation Manual Please read carefully before installation

Model 700 Microarray Oven

4000SS. For other repair kits and service parts, send for Ames Repair Parts Price List, PL-A-RP-BPD.

We greatly appreciate your business and promise to work hard to provide you with the highest level of service at all times.

Kompensator External Low Voltage Heating Cable System

SERIES 9000 Double Offset HP Butterfly Valves

Read this entire manual before operation begins.

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

TALCO FIRE SYSTEMS. LSF Start-Up Instructions. 1) IMPORTANT: Inspect the unit for damage. Report any damage to the freight carrier immediately.

INSTALLATION, OPERATION & MAINTENANCE MANUAL

DeZURIK 24 and Larger BHP High Performance Butterfly Valves WITH (FB) FYRE-BLOCK SEAT

2013+ Focus ST Focus ROUSH Exhaust Kit

Patient Care Facility

INSTALLATION INSTRUCTIONS SECURITY SHUTTER MODEL 523

Series 957, 957N, 957Z, 957RPDA, 957NRPDA, 957ZRPDA

User s Manual and Operating Instructions

KEYSTONE SERIES 320 BUTTERFLY VALVES INSTALLATION AND MAINTENANCE INSTRUCTIONS

Installation Manual DIAPHRAGM WELL TANK

CRD610 Automatic Fitting Inserter

OPERATING MANUAL READ INSTRUCTIONS THOROUGHLY BEFORE OPERATING CH-5 & CH-5AL CHEETAH BEAD SEATER CH-10 & CH-10AL CHEETAH BEAD SEATER

Owner s Manual GLASSLINED PUMP TANK

Interior Digital Load Scale 202-DDG-02. Installation and Operation Manual Please read carefully before installation

BOLT-ON AND WELD-ON FLUSH FLOOR SLIDEOUT SYSTEMS OPERATION AND SERVICE MANUAL

Transcription:

ELECTRIC ACTUATOR AND CONTROLLER FOR AKRON BUTTERFLY VALVES INSTALLATION INSTRUCTIONS The electric actuator and controller is designed to operate current model Akron Style 7940, 7945, 7950 and 7960 Butterfly Valves up to 250 psi working pressure. These instructions are prepared to accommodate conversion of current design values now in service using manual handle, handwheel or pneumatic operators. I. CONVERSION OF MANUAL HANDLE (Figure 1) A. Remove handle bolt (pc. 1). B. Remove washer and handle (pcs 2 & 3). C. Remove notched throttle plate and bolts (pcs 4 & 5). D. Enlarge four (4) bolt holes in mounting flange with 15 32 drill. E. See Section IV for installation instructions. II. CONVERSION OF HANDWHEEL OPERATOR (Figure 1) A. Remove four (4) bolts (pcs. 5) through mounting flange and lift handwheel operator (pc. 6) off. B. Enlarge four (4) bolt holes in mounting flange with 15 32 drill. C. See Section iv for installation instructions. III. CONVERSION OF AIR ACTUATOR (Figure 1) A. Remove three (3) bolts (pcs. 5) through mounting flange and lift air actuator (pc.7) off. B. Enlarge four (4) bolt holes in mounting flange with 15 32 drill. C. See Section IV for installation instructions. IV. INSTALLATION OF ELECTRIC VALVE ACTUATOR (Figure 2) A. Position actuator as shown in Fig. 2, View A. B. Remove cover by removing four (4) allen head screws with 3 32 Allen wrench. C. Verify gear sector is in same position as shown. If it is not, use a 7 16 socket wrench to position correctly by turning shaft. D. Replace cover. E. Set butterfly disc in fully open position. F. Mount actuator on 5 8 square shaft positioning the four (4) studs through holes on mounting flange (Fig 2, View B). Actuator may be mounted in one of four positions. G. Place lock washer and nuts onto protruding studs and tighten alternately. H. Proceed to Section V for control installation. 110011

V. MASTER CONTROLLER INSTALLATION NOTE: This controller may only be used with Akron Electric Valve Actuator. Do not attempt to use it with other actuators or damage will occur. This new design controller may be used with all 4 through 6 butterfly valves and actuator must be marked on gear housing, 64:1.! CAUTION: Always disconnect all wiring and cables from the valve controller before electric arc welding at any point on apparatus. Failure to do so will result in damage to the controller. A. Select the mounting location on the control panel for the controller. The controller is mounted from the outside of the panel and will need a clear space behind the mounting position of 2.5 inches. The dimensions of the panel cutouts for the controller housing and mounting screws are shown on the attached template (Figure 3). If not already made, these holes should be cut at this time.! WARNING: The controller is a sealed unit and should not be disassembled. Disassembly will damage the seal. This can result in the controller malfunctioning. B. Attach the controller to the panel using the four screws provided. C. Connect the 12 volt electrical system of the apparatus to the controller. Use the proper wire gauge when connecting the controller to the power hook-up. Depending on the distance of the controller from the power source, the following wire gauge size is recommended. 6 feet or less - 16 AWG or heavier 10 feet or less - 14 AWG or heavier 15 feet or less - 12 AWG or heavier 25 feet or less - 10 AWG or heavier NOTE: Any intermediate connections or loads between controller and power source can impact operation of the controller. It is recommended that direct runs be used for all connections. Do not splice. Use good weatherproof connections. (Controller supplied with Weatherpack connector.) A minimum of 11.5 volts is required under full load (28 amps). Typical current draw is 2 to 4 amps during normal travel; however, when the mechanical stop is contacted current draw can reach 28 amps. This will activate the red and green lights on the controller. For maximum performance, engine should always be running when operating the valves. CAUTION: Exercise caution when working with the truck electrical system. Disconnect cable from truck battery postiive tgerminal before connecting power to controller. See truck manual for additional information. NOTE: It is essential taht the connections must be watertight to prevent water from wicking up the wires into the controller. Therefore, the unit is provided with a weatherpack connector, (See Figure 2) which we recommend using. The information for mating connector is provided in Figure 2. D. Attach provided 10 foot wiring harness to valve motor and controller. (One additional wiring harness may be added to a maximum of 20 feet.) Typically, a master controller is the main link between the power source and the motor/actuator. Never use more than 20 feet of wiring harness between them. Never splice a wiring harness or connect through collector (slip) rings, as voltage drop will be increased. Never install master controller in a position requiring power wire to connect through collector (slip) rings. Distances beyond 20 feet will require an auxiliary (or dual) controller. These controllers, Page 2

(connected to the master controller) can operate up to 370 feet away from the master control. Also, the auxiliary cable can be spliced to connect through turret collector (slip) rings on aerial devices. NOTE: All splices must be well sealed to prevent water from wicking through the wires into the controller. E. Once installation is complete, operate the controller Open/Close switches through a complete cycle to ascertain that the valve is operating properly and to calibrate the valve position readout. VI. AUXILIARY CONTROLLER INSTALLATION NOTE: The auxiliary controller may only be used with Akron Master Controller. Auxiliary controller to be installed at desired at desired location following same mounting instructions as master controller. It is recommended that if a customer wants to separate the auxiliary control from the master control a great distance (i.e., aerial basket, etc.), the auxiliary must be the control package the farthest distance away. The master control must be closest to the power supply, and the valve. The 6 wire connecting cable between the master and auxiliary should be spooled, if required, and no smaller than 18 AWG per strand. This will allow a separation of up to 370 feet between the master and auxiliary control package. If a dual control package is used on an aerial, it is also recommended that the Brad Harrison receptacles be used to make the connection through the turret slip rings. A 10 1 2 foot connector cable from the auxiliary controller is to be connected to the mating 6 inch cable on master controller. If additional length is needed, extensions are available. 11 foot - P/N 7820-0101, 35 foot - P/N 7820-0100, 125 foot - P/N 7820-0103. VII. OPERATING INSTRUCTIONS The electrically actuated valve is operated by the momentary Open/Close switches, (Figure 4 & 5) of the controller mounted on the apparatus control panel. The controller features a lighted display indicating when the valve is fully open (Green), in a throttling position (Yellow) or fully closed (Red). TO OPEN VALVE - Push the OPEN valve button, hold the button until the valve attains the desired position, then release the button. TO CLOSE VALVE - Push the CLOSE valve button, hold the button until the valve attains the desire position then release. AUXILIARY CONTROLLERS Both master and auxiliary controllers operate using the same procedure. However, master controller will override any auxiliary operations. MANUAL VALVE OPERATION - If the valve fails to oeprate during use, disconnect the electrical connector on the valve. With a 7 16 wrench, turn the hex head (Figure 6A) on the end of the motor Page 3

drive shaft, to open or close the valve. DANGER - Always disconnect the electrical connector on the valve when the gear cover is removed. KEEP FINGERS AWAY FROM THE MOVING GEARS!! WARNINGS Not recommended for use flowing salt water. After use with foam, flush with fresh water. For use by trained firefighting personnel ONLY. Charge all lines slowly to facilitate a controlled water pressure build up during start up. For firefighting use ONLY. For use with water or standard firefighting foams ONLY. Replace any tags or bands that are worn or damaged and cannot be easily read. Your Butterfly Valve should be inspected prior to and after each use, to ensure it is in good operating condition. Periodically, an unanticipated incident may occur where the Butterfly Valve is used in a manner that is inconsistent with standard operating practices and those listed in IFSTA. A partial list of potential misuse follows: 1. Operating above maximum rated pressure and flow. 2. Not draining, and allowing water to freeze inside the valve. 3. Prolonged exposures to temperatures above +130 degrees F, or below -25 degrees F. 4. Operating in a corrosive environment. 5. Other misuse that might be unique to your specific firefighting environment. Also, there are many tell tale signs that indicate Butterfly Valve repairs are in order, such as: 1. Controls that are either inoperable or difficult to operate. 2. Excessive wear. 3. Water leaks. If any of the above situations are encountered, the Butterfly Valve should be taken out of service and repaired, plus tested by qualified valve technicians, prior to placing it back into service. USE ONLY AKRON BRASS CERTIFIED REPLACEMENT PARTS Butterfly Valves contain plastic and rubber components. The components can be damaged if cleaned with industrial strength cleaners and solvents. Always use warm water and a mild detergent when cleaning the valve s rubber and plastic components. The Butterfly Valve is configured for optimum performance. Do not alter in any manner. The Electric Butterfly Valve Actuator has been developed for use on Akron Brass Butterfly Valves. Do not attempt to install this electric operator on any other product other than those sold and approved by Akron Brass. Akron Brass valve actuator must be used in conjunction with the Akron Brass push button/indicator controller. They are a matched pair. Do not attempt to use either the actuator or the controller in any installation independently. Page 4

FIGURE 1 Page 5

FIGURE 2 Page 6

FIGURE 3 Page 7

FIREFIGHTING EQUIPMENT 6 Inches 4 1/4 Sq. OPENED THROTTLED CLOSED 3 5/8 OPEN CLOSE MASTER CONTROLLER FIGURE 4 2 15/16 To Valve B A Mating Connector Specifications 12015792 Tower (1) 12124580 Terminal Sleeve (2) 12010293 (2) 4 1/4 Sq. FIREFIGHTING EQUIPMENT OPENED THROTTLED CLOSED 10 1/2 Feet 3 5/8 OPEN CLOSE AUXILIARY CONTROLLER FIGURE 5 2 15/16 FIGURE 6 PHONE: 330.264.5678 or 800.228.1161 I FAX: 330.264.2944 or 800.531.7335 I www.akronbrass.com Available in Canada through AKRON MANUFACTURING COMPANY PHONE: 519.773.8431 I FAX: 519.773.3794 AB-693 (REV. 05/01) ISO 9001 REGISTERED COMPANY WARRANTY AND DISCLAIMER: We warrant Akron Brass products for a period of five (5) years after purchase against defects in materials or workmanship. Akron Brass will repair or replace product which fails to satisfy this warranty. Repair or replacement shall be at the discretion of Akron Brass. Products must be promptly returned to Akron Brass for warranty service. We will not be responsible for: wear and tear; any improper installation, use, maintenance or storage; negligence of the owner or user; repair or modification after delivery; damage; failure to follow our instructions or recommendations; or anything else beyond our control. WE MAKE NO WARRANTIES, EXPRESS OR IMPLIED, OTHER THAN THOSE INCLUDED IN THIS WARRANTY STATEMENT, AND WE DISCLAIM ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. Further, we will not be responsible for any consequential, incidental or indirect damages (including, but not limited to, any loss of profits) from any cause whatsoever. No person has authority to change this warranty. Premier Farnell Corporation. 2000 All rights reserved. No portion of this can be reproduced without the express written consent of Premier Farnell Corporation.