BAL3000 BAL3000. Fluorescent Emergency Ballast Lumens. Specification Sheet. Emergency Ballast 1/19/2012. Project: Catalog#: Approved by:

Similar documents
UL AND CODE COMPLIANCE

BAL1400 FLUORESCENT EMERGENCY BALLAST Specification-grade One or two-lamp emergency illumination

BAL3000 FLUORESCENT EMERGENCY BALLAST Specification-grade: Up to 3500 lumens One or two-lamp emergency illumination

Installation Instructions

FLUORESCENT EMERGENCY BALLAST Lumens. When using this lighting device safety precautions should be followed at all times

WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE OBSERVED INCLUDING THE FOLLOWING:

BALT5-800 LOW-PROFILE FLUORESCENT EMERGENCY BALLAST

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

3. Please ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.

UFO-RP2 FLUORESCENT BATTERY PACK IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

UFO-RP3 FLUORESCENT BATTERY PACK IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

INSTRUCTION MANUAL. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following:

KT-EMRG-1400-SL /B. 3. Please ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.

SURE-LITES FBP140XLP Instruction Manual

SAVE THESE INSTRUCTIONS

SPECIFICATION SHEET :FH6-DUAL-3000L. Project Type Model # Remarks

Morris Products 53 Carey Road, Queensbury, NY 12804

INSTRUCTION MANUAL. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following:

Installation And Operation Instructions For FHSCP-UNV Series Emergency LED Drivers Models: FHSCP-UNV-5WL, 7.8WL, 10.7WL, 13.

B33 INSTALLATION INSTRUCTIONS ! IMPORTANT SAFEGUARDS!

PSL600 MVOLT SD INSTALLATION INSTRUCTIONS ! IMPORTANT SAFEGUARDS!

Installation and Operation Instructions 10/04/13

IMPORTANT SAFEGUARDS

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR NEW YORK 18 WATT SERIES

Ni - Cd THIS PRODUCT CONTAINS A RECHARGEABLE NICKEL-CADMIUM BATTERY. THE BATTERY MUST BE RECYCLED OR DISPOSED OF PROPERLY.

Installation Instructions Central Battery Units

B30ST ! IMPORTANT SAFEGUARDS! SAVE THESE INSTRUCTIONS. Installation Instructions SELF-TESTING EMERGENCY LIGHTING EQUIPMENT

Cat# DC LED Array Emergency Driver

Ni - Cd THIS PRODUCT CONTAINS A RECHARGEABLE NICKEL-CADMIUM BATTERY. THE BATTERY MUST BE RECYCLED OR DISPOSED OF PROPERLY.

Ni - Cd THIS PRODUCT CONTAINS A RECHARGEABLE NICKEL-CADMIUM BATTERY. THE BATTERY MUST BE RECYCLED OR DISPOSED OF PROPERLY.

Lumencia. LLMPS SERIES Micro Power Systems. Multi-Unit Residential Lighting. Job Name: Type:

Ni - Cd THIS PRODUCT CONTAINS A RECHARGEABLE NICKEL-CADMIUM BATTERY. THE BATTERY MUST BE RECYCLED OR DISPOSED OF PROPERLY.

TRUET5 EXT (DIMMABLE)

Installation Instruction

Sure-Lites. Installation Instructions for the Sure-Lites UX Self Powered Exit Sign with Self Diagnostics. IB505037EN Important Safeguards

SAVE THESE INSTRUCTIONS

A Home Depot Company. Quality Lighting for Every Facility

& EXIT SIGNS. & exit signs

MaxLite LED UTILITY WRAP FIXTURES

Installation Instructions: External-Driver SEP T8 LED Tube Lamp

HIGHBAY RAIL 400W INSTALLATION INSTRUCTIONS

EMIU 720W Mini Inverter

2D products are warranted for one year, the expected life of the ballast and/or Emergency module is 5 years

LUMENTON. including poured concrete. Suitable for installation within 4 feet of ground. Product specifications subject to change without notice.

Doc Ref: WD024/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

AEROBAY INSTALLATION INSTRUCTIONS

3-Wire Control, 220/240 Volt T-8 Linear, T-4 Quad Tube and T-5 Twin Tube Lamps

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE EMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

Sure-Lites LPXC SERIES. Input Voltage Input Power 19 3/4" " /8" /8" 54 13" /2" 191

Self-Testing Industrial Series

R. STAHL Schaltgeräte GmbH Geschäftsbereich Leuchten Nordstraße Weimar, Germany

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE LMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

Lighting Tables for Existing/Base Equipment 4/15/2011

Assembly Instructions Retrofitting

MANUFACTURED IN THE UK

Strip Fixture URS Light Bar Retrofit Installation Instructions Revised:

SPECIFICATION SHEET : FHS2-UNV-36L

Spectron Industrial Series

MHD2/MHDO SERIES MHD2. Marine Heavy Duty Outdoor Non-Metallic Fluorescent CLASS 1 DIVISION 2 FLUORESCENT LIGHT

This Driver Will Operate Constant Current LED Arrays With a Working Voltage Between 11-56VDC And Not Exceeding 20W.

Universal Retrofit System Installation Instructions Revised:

Installation Instructions and User Manual For. 100 Watt Inverter Power System

A R C H I T E C T U R A L LO W L E V E L F LO O D L I G H T S E R I E S

SAVE THESE INSTRUCTIONS

MANUFACTURED IN THE UK

MHD2/MHDO SERIES M H D 2. Marine Heavy Duty Non-Metallic Fluorescent

Explosion Proof Emergency Exit Sign - 90 Minutes Battery Backup - 120/277V - Emergency Lighting Syst

R. STAHL Schaltgeräte GmbH Geschäftsbereich Leuchten Nordstraße Weimar, Germany

EEQ SERIES COMPACT FLUORESCENT EMERGENCY FACTORY SEALED LIGHTING FIXTURES

DHFR Recessed Vertical Fluorescent Downlight General Remodel 4, 5, 6 Aperture

MIRRORLITE RECESSED EMERGENCY LIGHTING

UV16 vandal resistant, wet/damp location emergency lighting

Compact Fluorescent Lampholders

Installation Instructions: Memory-Dimmable SEP T8 Tube Lamps

Installation Instructions: ACCENT SYSTEM

Doc Ref: WD029/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

LED microwave sensor T8 tube light

Compact SE Overview. High-Performance Dimming. Ballast

Installation Instructions & Users Manual IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

ICN2S40N35I Ele Ballast (2) F40T V

IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed including the following:

FHSCP-UNV-10P-L-SD INSTALLATION INSTRUCTIONS

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS!

Installation And Operation Instructions

ELECTRICAL SYSTEM RP-7

Lighting Tables for Existing/Base Equipment 4/15/2011

ELECTRONIC FLUORESCENT BALLASTS

ECO-T LED RECESSED TROFFER USER MANUAL

Linear Tubes Compacts

Class I, Div. II Fluorescent Fixture - Emergency Battery Backup - Corrosion Resistant (Saltwater) -

Idaho Profile System - Trimless

Fixed Head Emergency Lights

Compact Fluorescent Plug-Ins

New York City Approved. emergency lighting

Incentives for Energy Efficient Lighting (Effective August 8, 2015 through December 15, 2015 * )

RSS SERIES R S S. Fluorescent Lighting for Hazardous Locations

Lighting Tables for Existing/Base Equipment 1/1/2014

ELECTRONIC FLUORESCENT BALLASTS

Project. Comments. Prepared by

Transcription:

1/19/2012 Fluorescent 1450-3000 Lumens Works in conjunction with an AC ballast to convert new or existing fluorescent fixtures into unobtrusive emergency lighting Maintains illumination of one or two lamps in the emergency mode for a minimum of 90 minutes Features Provides a minimum of 90 minutes of emergency illumination Can be installed inside, on top or in remote* of the fixture Specification Grade Can be used in both switched and unswitched fixtures UL 924 Listed for damp location UL listed for Retrofit/Field Installation Life safety NFPA 101 NEC/OSHA Meets most state and local codes Electrical Dual Voltage Input 120V/277 VAC, 60Hz Solid-state charger circuit Test Switch/Power Indicator light Temperature Rating (Ambient): 0ºC to 50ºC [32ºF to 122ºF] Maintenance-free, long life, Sealed Nickel Cadmium Battery Maximum battery recharge time: 24 hours Project: Catalog#: Approved by: Lamp Compatibility Compatible with 1-lamp, 2-lamp, 3-lamp and 4-lamp fixtures with many ballast types including standard, rapid-start, slimline, instant-start, dimming and electronic AC ballast consult factory regarding specific applications Compatible with many different lamp types to page 2 or contact customer service for more information NEW! Low Voltage LED Combo Switch! Housing Painted-red steel housing with 2 conduit on one end Dimensions Illumination Operates one or two lamps in the emergency mode for a minimum of 90 minutes please refer to page 2 for more information Provides a maximum initial lumen output of 3000 Lumens 16.3 1.75 5.5 * Conditions apply for remote mounting. Check with the factory for more information.

Lamp Compatibility Data Model No. No. Of BAL650C-2 BAL650C-4 BAL500 BAL700 BAL1400 Lumen Ouput Operated 650 750 500 700 1400 3000 Linear Fluorescent Compact Fluorescent Special Fluorescent T8 T10 T12 4-Pin CFL 4-Pin Long CFL 1 Lamp - 17-40 17-40 40-110 40-110 40-215 2 Lamp - - - 17-40 17-40 17-40 1 Lamp - 17-40 17-40 - - - 2 Lamp - - - 17-40 17-40 17-40 1 Lamp - 17-40 17-40 40-110 40-215 40-215 2 Lamp - - - 17-40 17-40 17-40 1 Lamp - 40-42 13-39 40-42 40-42 - 2 Lamp - 13-39 - 13-39 13-39 13-42 1 Lamp - 40-42 13-39 40-50 40-50 40-55 2 Lamp - 18-40 - 18-40 18-40 18-40 2-Pin CFL 1 Lamp 13-26 - - - - - T9 Circline CFL U-Bent T8 T12 1 Lamp - 20 20-40 - - - 2 Lamp - - - 20-40 20-40 20-40 1 Lamp - 32,40 32,40 - - - 2 Lamp - - - 32,40 32,40 32,40 1 Lamp - 32,40 34,40 - - - 2 Lamp - - - 34,40 34,40 34,40 In applications involving 2, 3, or 4-lamp instant start ballasts, for 2-lamp emergency operation, only 1 lamp will go dim in the test mode. When power is cut off to the fixtures, both lamps will come on (in EM Mode) as they are suppose to.

Installation Instructions When using this lighting device the safety precautions should be followed at all times. PLEASE READ CAREFULLY AND FOLLOW ALL INSTRUCTIONS FOR YOUR OWN SAFETY 1. This device is designed for indoor use. Do not use outdoors. 2. Prior to installation, battery connector must be open to prevent high voltage from being present on our put leads (red & yellow). 3. This device is designed for use with most 17W through 215W single pin or bipin fluorescent lamps, from 2-8. These fluorescent lamps are commonly available on the market. Please use standard, energy saving, HO, VHO, PG17, circline or (4-pin) long compacts with no integral starter. 4. Please ensure the electrical connections conform to the National Electrical Code and local regulations if applicable. 5. To avoid electric shock, please disconnect normal and emergency power supplies and battery connector of the emergency ballast before servicing. 6. This device is designed for factory or field installation in either the ballast channel or on top of the indoor fixtures. Do not install this device near gas or electric heaters. 7. AC power source of 120VAC or 277VAC is required. 8. The battery is sealed, non-maintenance, and is not replaceable in the field. Please contact manufacturer for information on service. Do not attempt to service the battery please. 9. Do not use accessory equipment that is not recommended by manufacturer. Failure to do so may cause unsafe conditions. Servicing should only be performed by qualified service personnel. 10. Do not use the product for other purpose that is the product is NOT designed for.

Specification Sheet Installation Instructions NOTE: All the branch circuit wiring has to be ready as well as an unswitched source of power before the fixture is installed. Confirm that the same branch circuit runs the emergency ballast and the AC ballast. CAUTION: Battery connector has to be opened for preventing high voltage on output leads (red & yellow). Wait until all the installation process is completed and AC is supplying power to the emergency ballast then join the battery connector. 1/2 std. Knockout 7/8 hole w/ conduit connector DIAGRAM 1 1. AC power has to be off before installation. 2. Choose the right wiring diagram to connect the emergency ballast to AC ballast and lamp. 3. Please ensure the electricity connections conform to the National Electrical Code and local regulations if applicable. Follow diagram 1, install the emergency ballast on the top of the fixture or follow diagram 3 to remotely install up to half distance the AC ballast manufacturer recommends install the AC ballast from the lamp or within 50 feet is recommended. (Choose the one in less distance). 4. To install the test switch, it would go through the side of a strip fixture R the ballast channel cover of a troffer. Follow diagram 4 to drill a 1/2 hole and install the test switch. In order to remove AC power from both the emergency ballast and the AC ballast, the test switch has to be connected properly (check diagram 2). 5. Matching violet and brown leads to connect the charging indicator light to the emergency ballast (Check diagram 4). 6. Please search in readily visible location and stock the label with CAUTION: This Unit Has More Than One Power Supply Connection Point. To Reduce The Risk Of Electric Shock, Disconnect Both The Branch Circuit-Breakers Or Fuses And Power Supplies Before Servicing. 7. Do not join the inverter connector until the fixture is completely installed and supply AC power to the emergency ballast. 8. The battery needs to be charged for one hour in order to have shortterm testing on the emergency function. Before having a long-term emergency function testing, the battery in emergency ballast has to be charged for 24 hours. DIAGRAM 3 REMOTE INSTALLATION 2 Conduit with conduit connector provided HOT TEST SWITCH Breaking the Hot (SWITCH Provided) COM HOT TEST SWITCH Breaking the Hot (SWITCH Provided) COM DIAGRAM 2 UNSWITCHED FIXTURE WHITE AC SWITCHED FIXTURE WHITE AC Drill 1/8 holes for mounting screws 120V OR ORANGE 277V EMERGENCY WHITE 120V OR ORANGE 277V EMERGENCY WHITE EMERGENCY JUNCTION BOX Half the distance recommended by the AC ballast manufacturer, or up to 50 feet. Choose the one in less distance. FIXTURE

Installation Instructions TROFFER STYLE FIXTURE Channel Cover Leads to Charging Indicator Light DIAGRAM 4 Indicator Light STRIP SYTLE FIXTURE Fixture Violet (+) Brown (-) Indicator Light Fixture Violet (+) Brown (-) 7/8 Punch 7/8 Bushing Inserted into Channel Cover 1/2 White Bushing 1/2 Punch 5/8 Black Bushing 1/2 White Bushing 5/8 Black Bushing Plastic Tubing (cut to necessary length) 1/2 White Bushing to Hold Charging Indicator Light Fixture Lens Indicator Light (on top) AC (on top) Charging Indicator Light Test Switch Charging Indicator Light Test Switch NOTE: After installing the charging indicator light and test switch, mark each with the appropriate label. OPERATION: THE CHARGING WOULD BE ON TO INDICATE THE BATTERY IS BEING CHARGED WHEN AC POWER IS APPLIED. THIS EMERGENCY WOULD FUNCTION AND OPERATE ONE OR TWO S WHEN THE AC POWER IS FAILED. THE DEVICE OF THIS EMERGENCY WILL OPERATE 17 WATT TO 215 WATT S AT LEAST 90 MINUTES. MAINTENANCE: NOTE: SERVICES SHOULD ONLY BE PERFORMED BY QUALIFIED PERSONNEL. THE EMERGENCY SHOULD BE CHECKED PERIODICALLY TO CONFIRM FUNCTIONING AND THE FOLLOWING SCHEDULE IS RECOMMENDED 1. TO INSPECT THE CHARGING EVERY MONTH AND CONFIRM THAT IS ILLUMINATED. 2. PUSH THE TEST SWITCH FOR 30 SECONDS TO ENSURE THE EMERGENCY IS FUNCTIONING, RECOMMENDED TO PERFORM THIS TEST EVERY 30 DAYS. 3. PERFORMING A LONG-TERM (90 MINUTE BATTERY DISCHARGE) IN EVERY YEAR. ONE OR TWO S SHOULD BE OPERATED FOR NO LESS THAN 90 MINUTES. 4. BEFORE THE BATTER IS REPLACED, DISCONNECT, SWITCHED AC POWER AND UNSWITCHED AC POWER FROM THE FIXTURE. AFTER THE BATTER IS REPLACED, SUPPLY THE AC POWER TO THE FIXTURE AND RECONNECT THE. THE CHARGING SHOULD BE ON AFTER THE BATTER IS REPLACED. IF THE BATTERY NEEDS TO BE REPLACED, CONTACT THE MANUFACTURER.

Lamp Diameter 1, 1-1/4, 1-1/2 (T8, T9, T10, T12) TABLE 1 (FOR ) LONG COMPACT TWIN/QUAD/TRIPLE TWIN/ QUADRUPLE TWIN TUBE COMPACT Base Type SINGLE OR BIPIN 4-PIN (2G11) 4-PIN (G24q, GX24q) 4-PIN (GR10q) Power (Length) Number of Emerg. 17-40W (2-4 ) 40-215W (5-8 ) 18-39W 40-55W 18-42W 16-38W 55W 1 2 1 1 2 1 1 2 1 2 1 Brown Connector CLOSE OPEN OPEN CLOSE OPEN OPEN CLOSE OPEN CLOSE OPEN OPEN 2D Wiring Diagrams - 1 Lamp Operation Note: and AC must be fed from the same branch circuit. Typical Schematics only, may be used with other ballasts, consult the factory for other wiring diagrams. A. One (1) Lamp Rapid Start B. Two (2) Lamp Rapid Start 1 building grounding building grounding WHITE (emergency) WHITE C. Three (3) Lamp Rapid Start D. Four (4) Lamp Rapid Start /WHT /WHT 3 building grounding WHITE YEL/WHT OR YEL/WHT OR 4 3 4 (emergency) building grounding /WHT /WHT /WHT /WHT WHITE NOTE: Use the proper tap cap to unswitched AC lead.

Wiring Diagrams - 1 Lamp Operation Note: and AC must be fed from the same branch circuit. Typical Schematics only, may be used with other ballasts, consult the factory for other wiring diagrams. E. One (1) Lamp Instant Start 1 building grounding F. Two (2) Lamp Instant Start building grounding G. Three (3) Lamp Instant Start WHITE (emergency) H. Four (4) Lamp Instant Start WHITE 3 building grounding or 4 building grounding WHITE 3 WHITE 4 (emergency) I. One (1) 4-Pin Compact Lamp Rapid Start J. Two (2) 4-Pin Compact Lamp Rapid Start 1 building grounding building grounding WHITE = Lamp WHITE

Wiring Diagrams - 1 Lamp Operation Note: and AC must be fed from the same branch circuit. Typical Schematics only, may be used with other ballasts, consult the factory for other wiring diagrams. K. One (1) Lamp Circline Rapid Start 1 CIRCLINE CONNECT LEADS building grounding L. Two (2) Lamp Circline Rapid Start WHITE CIRCLINE CONNECT LEADS building grounding WHITE WHITE WHITE Wiring Diagrams - 2 Lamp Operation M. Two (2) Lamp Rapid Start (emergency) N. Two (2) Lamp Instant Start DO NOT CONNECT LEADS building grounding DO NOT CONNECT LEADS building grounding (emergency) (emergency) O. Three (3) Lamp Rapid Start WHITE (emergency) (emergency) P. Three (3) Lamp Instant Start WHITE /WHT /WHT 3 DO NOT CONNECT LEADS building grounding 3 DO NOT CONNECT LEADS building grounding or (emergency) WHITE (emergency) WHITE

Wiring Diagrams - 2 Lamp Operation Note: and AC must be fed from the same branch circuit. Typical Schematics only, may be used with other ballasts, consult the factory for other wiring diagrams. Q. Four (4) Lamp Rapid Start YEL/WHT OR YEL/WHT OR 4 4 (emergency) DO NOT CONNECT LEADS building grounding /WHT /WHT /WHT /WHT S. One (1) Lamp without AC WHITE R. Four (4) Lamp Instant Start 4 3 4 (emergency) DO NOT CONNECT LEADS building grounding WHITE Wiring Diagrams - Only Fixtures T. Two (2) without AC building grounding CAP DO NOT CONNECT LEADS building grounding CAP (emergency) WHITE U. One (1) 4-Pin Compact Lamp without AC (emergency) WHITE V. Two (2) 4-Pin Compact without AC building grounding CAP DO NOT CONNECT LEADS building grounding CAP WHITE WHITE