solenoid technology safety line kec group power of partnership and magnetism

Similar documents
High Power Line. Direct-Acting Solenoids Reversible Solenoids

Locking Line. Electromagnetic Locking Systems

10 Load and Motor Switchgear

System Line. AC Single-Stroke Solenoids

High Power Line. Direct-Acting Solenoids Reversible Solenoids

Locking Line. Electromagnetic Locking Systems

Kendrion magnetises the world. Electromagnetic Solutions for Industrial Applications

System Line. AC Solenoids

Accessories Cable glands

Locking Line. Locking Solenoids

Control Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België

Operating pressure (bar) kv factor (m 3 /h) *3)

Oscillating Line. Electromagnetic vibrating systems

Flow. group *2) G1/4 1, , B G1/ , B /4 NPT , B N/en

Solenoid Operator 0516 / 1216

Solenoid Operator 0513 / 1213

Electronic Modules and Components

MN-06. Standardized valve series 3/2-way acc. to NAMUR, 750 Nl/min (0.762 Cv) Technical data for series. Order code MN HN-142

COMBIBOX. Program Schedule. with an energised to engage single sided clutch without brake... COMBIBOX 09

Proportional Solenoids for Hydraulics G RC Y 037, 045, 063

Thermostats Series 142

EEX Line Spring-applied single-disc brake for potentially explosion hazardous areas

TER. Thermostats for Industrial Applications. Switching range: C to C. Housing material: aluminium. Capillary tube: copper

Specialist Article Kendrion IMS Donaueschingen. Actuators: Solenoid beats Pneumatics

3/2 Way Valve G1/8. Data Sheet No E. Characteristics Symbol Unit Description General Features Spool valve.

Switch to the right partner. Kendrion s magnetic actuators

MN-06. Standardized valve series 3/2-way acc. to NAMUR, 750 Nl/min (0.762 Cv) Technical data for series. Order code MN HN-142

On/Off- Solenoid to RL 94/9/EG (ATEX 95) G HP E Pamphlet

Proportional Solenoid for Hydraulics ATEX + IECEX

Threaded Resistance Thermometers Model TR10-C, with Fabricated Thermowell Model TW35

Explosion and flame-proof cast iron electric motors

3/2-way Rocker Solenoid Valve for pneumatic systems

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Solenoid System. The coil is also in conformity with 94/9/EC ATEX for electrical apparatus of group II, category 3 (Ex na II 3 GD T4 or T5).

On/Off- Solenoid to RL 94/9/EG (ATEX 95) G HP E

Technical Data Sheet

System 8. Solenoid Coils Armature Assemblies Valve Systems. Nass Controls LP Nass Magnet GmbH Precision Controls Kft.

Direct mounting NAMUR solenoid valves for process valve actuators New Revolutionary Design- Worldwide Patents Pending

Our policy is one of continued research and development. We therefore reserve the right

Lifting / Lowering valve type HSV and HZV

Proportional solenoid valve for pneumatic application V PR M

MINING ELECTRIC MOTORS 3KTCR AND 4KTCR

STAINLESS STEEL ARES PNEUMATIC ANGLE-SEAT VALVE

Material pressure (bar) (Cv (US) kv x 1,2 Seat

V82 series - Redundant valve manifold systems - Compact 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

Proportional solenoid valve for pneumatic application V PR M

98025 NAMUR/INLINE 3/2 way poppet valves electromagnetic actuated, indirectly controlled G 1/2, 1/2 NPT or flanged with NAMUR Interface

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Solenoid System KNURLED NUT TOP CORE GUIDE TUBE PLUNGER

Function. Orifice (mm) NBR (Perbunan) 0 EPDM 1 FKM (Viton) 2 FFKM (Kalrez) / O-ring FKM 4

Holtumsweg 13, D Weeze, Tel /9134-0, Fax /1444

Compact enclosures AE

97105 Inline. Ordering information. Technical data. Accessories See page 5

I Ex-Safety switches I

97300 NAMUR 3/2 & 5/2 way spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, NAMUR Interface

Explosion and flame-proof single phase electric motors

Electric Drives. Linear Motion and Assembly Technologies Pneumatics Service. Valves, Series VP15. Technical data

AC Line. Spring-applied single-disc brake A H E00 / E00

MESSKO MTO Oil Level Indicator

For single and double operated actuators. Exhaust air recirculation (3/2 way function)

Accessories for pneumatic stroke and rotary actuators CLASSIC and ELEMENT process valves

Electromagnetically actuated shotbolt lock unit G SC X... B01

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

Explosion-protected surface-mounting Thermostat ATH-Ex Series

Electrical position indicators and combi switchboxes for linear and quarter turn valves

Control and Terminal Box Type A21-**-*****

No more gasping for air. Kendrion s electromagnetic actuators

3-Way Solenoid Valve - Direct Acting

GEMÜ 205 Electrically operated solenoid valve

Operating Instructions for Float Flow Meter / Monitor. Model: SWK

Technical description... 1 Limit switches Mini Dimensions... 8 Power tables Spare part lists... 12

Abox Ex Rated Junction Boxes Explosion-protected enclosures for zones 2 and 22

DC Single-Acting High Performance Solenoids

Climatic proofing Damp heat, constant, to IEC Damp heat, cyclic, to IEC mm

Active Brake Line. Electromagnetic single-surface brake E E00

EJB Enclosures. ATEX II 2 G Ex d IIB+H2 T6...T3 - II 2 D Ex td A21 T85 C C IECEx Ex d IIB+H2 T6...T3 - Ex td A21 T85 C...

9 Control Equipment. Control Unit System Series ConSig 8040

Proportional Solenoids

EXPLOSION PROOF DIRECTIONAL CONTROL VALVE TYPE ED6 SERIE 5X CENELEC STANDARD & ATEX DIRECTIVE

Servo-operated 2/2-way solenoid valves Type EV220A

To order, quote model number from table overleaf, e. g for a DN 25 valve.

Thread Mounted Resistance Thermometers Model TR201, with Fabricated Thermowell

Reed sensor For bypass level indicators Model BLR

5/2 and 5/3 Way Valves

Type Description Order Nº Packing Qty. IP 65 junction box complying with DIN VDE 0606, U i

A product of Coel Motori Srl, Milano, Italy

Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip

26230, NAMUR 3/2 & 5/2 Indirect solenoid actuated spool valves

Thermocouples Model TC10-B, for Additional Thermowell

MINING ELECTRIC MOTORS 3KTCR, 4KTCR, 5KTCR

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

Solenoid valve VDHT standard BSP (British Standard Pipe)

3/2 Directional Control Valves Direct solenoid operated poppet valves Internal thread G1/4, 1/4-18 NPT or flanged with NAMUR interface

Room thermostats type series TRM

Control Panels, Distribution Panels and Components

EExe and EExi terminal boxes in polyester and aluminium for Ex areas

Kämmer Actuators Series 4 Pneumatic and Electropneumatic

Active Brake Line. Electromagnetic single-surface brake E E00

15 mm Pilot Valve. More technical specifications are reported in the following pages. 1

Explosion proof electric motor For Fuel dispensing application. Main characteristic

Transcription:

solenoid technology holding systems for fire kec group protection, ventilation and air power of partnership and magnetism condition safety line

GT 42 R 001.01 GT 42 R 002.01 GT 50 R 001.01 GT 50 R 002.01 GT 63 R 001.01 GT 63 R 002.01 GT 70 R 001.01 GT 70 R 002.01 GT 42 R 090.01 GT 50 R 090.01 GT 63 R 090.01 GT 42 R 091.01 GT 42 R 092.01 GT 50 R 091.01 GT 50 R 092.01 GT 63 R 091.01 GT 63 R 092.01 1 without mounting flange 2 with mouting flange Surface solenoid zinc, galvanized Mounting wall mounting or assembly in any design. Fixing about three threads or threaded hole in the center. Connection flying leads terminal block plug connection DIN 43650 for underplaster installation without interruptor button. Surface solenoid zinc, galvanized Mounting put it in the cast precise opposite to the wing of a door underplaster installation Size Ø42-Ø50 in VP box Size 60 Size Ø63 in VP box Size 70 Connection flying leads for everplaster installation in plastic case with interruptor button. Surface solenoid zinc, galvanized Mounting wall mounting in opposite to the wing of a door Connection 1. through case opening 2. lateral stufting box screwings PG 9 001 002 Type Øa b c d e f g Øh i k L m GT42 42 25 4 26 M4 55 44 4,5 5 30 M5 6 GT50 50 30 4 34 M4 55 44 4,5 5 35 M8 8 GT63 63 30 4 44 M4 75 60 5,5 8 38 M8 8 GT70 70 35 5 56 M4 75 60 5,5 8 43 M8 8 Type Øa b c GT42 42 25 10 GT50 50 30 15 GT63 63 30 15 Type Øa GT42 42 GT50 50 GT63 63

GT 50 R 089.01 GT 50 R 081.01 GT 50 R 080.01 all metal solenoids zinc, galvanized with interruptor button Surface solenoid and distance tube zinc, galvanized Mounting B on the floor and plafond mounting Standard length dimension X: 150, 300, 450 mm reduce until 110 mm possible Mounting A wall mounting Standard length dimension X: 185, 335, 485 mm reduce until 145 mm possible. The magnet head can be rotable from position A to B solenoid zinc, galvanized with plastic base underplaster connection degree of protection according to DIN 40060: device IP 40 Application can be installed in any constructions elements, for wall mounting in dry areas Montage Location = wall opposite the door to be kept open Inquiry Connection box double-pole Combined Specification: solenoid and tube zinc galvanized, magnet mount made of plastic Application where the hight of the magnet may need adjustment to suite side conditions Connection for floor, ceiling and wall installaton Mounting B with interruptor button (wall installation design A ). Design A Design B Design B Design A Length X = 150 mm B = reduce until 125 mm possible Length X+25 = 175 mm A = reduce until 156,5 mm possible

GT 50 R 060.01 GT 63 R 060.01 GT 70 R 060.01 in plastic case with interruptor button release on the right or left Surface solenoid zinc galvanized Mounting floor mounting behind the open door Connection through case opening from the bottom GT 50 R 050.01 (ed 1475/5 D)* GT 70 R 050.01 (ed 1475/7 D)* *VDS finishing observe (3 Watt Version) - note: II 2 G EEx m e II T6 - TÜV 01 ATEX 1778X- Ex- impact cast metal housing approved 24 V DC max. currant 325 ma. Standart with reverse battery protection, degree of protection according to DIN 40050: device IP 54 Surface housing is grey lacquered, solenoid chemically nickel-plated Mounting wall mounting or assembly in any design Connection cable entry PG 16 Operative range category 2 G for explosion proof solenoids with EURONORM an approval chemically nickel-plated armature command Projection x GT 50 R 1/38 GT 70 R 1/22 Germ. LLoyd: Nr.70 319-76 HH for installation an ships or outdoors degree of protection according to DIN 40050: device IP 56 magnet mount made of AI with solenoid diameter 50 or 70 mm, metal terminal box without interruptor button, with reverse battery protection Surface casing is grey lacquered, solenoid zinc galvanized Mounting wall mounting or assembly in any design Connection metal connecting box with 2 lateral stuffing box screwings PG 13,5 x Type Øa b GT50R060 50 3,5 GT63R060 63 3,5 GT70R060 70 8,5 Type Øa x GT50R050 50 14 GT70R050 70 14 Ankertypen GT50 R105-200 GT70 R105-200 GT...R 106-200; GT...R 107-200 correct scale to be in accordance with the performance. GT...R 006-200; GT...R 007-200 with chemically nickel-plated armature-plate. Type Øa GT50R 50 GT70R 70

GT 42 R 005 GT 42 R 006 GT 50 R 005 GT 50 R 006 GT 63 R 005 GT 63 R 006 GT 70 R 005 GT 70 R 006 GT 42 R 007 GT 50 R 007 GT 63 R 007 GT 70 R 007 Flexible armature 005 Application The armature plate is intended to ensure the magnetic contact of solenoid and the door Flexible armature 006 for extrem adjustment 60 Surface armature zinc galvanized Telescopic armature 007 Application now design 005 but armature plate movable with telescopic leding, way of the spring 20 mm The telescopic armature damps by spring force the impact Type Øa b c d Øe f g GT42 45 18 55 44 4,5 5 5 GT50 55 18 55 44 4,5 5 5 GT63 65 23 75 60 5,5 8 7 GT70 75 26 75 60 5,5 8 10 Magnet force in accordance with datasheet only with original armature. Type Øa b c d Øe f g GT42 45 50 55 44 4,5 5 5 GT50 55 50 55 44 4,5 5 5 GT63 65 55 75 60 5,5 8 7 GT70 75 56 75 60 5,5 8 10 Type Øa b c d Øe f g GT42 42 79 55 44 4,5 5 5 GT50 55 79 55 44 4,5 5 5 GT63 65 81 75 60 5,5 8 7 GT70 75 84 75 60 5,5 8 10

Type el. power voltage (DC) holding force N VdS-key* GT 25 R 1,5 Watt 24 107 N - GT 42 R 1,5 Watt 24 300 N 23055 GT 50 R 1,5 Watt 24 490 N 23001 3,0 Watt 24 588 N 23001 5,0 Watt 24 686 N - GT 63 R 1,5 Watt 24 700 N 23049 GT 70 R 1,5 Watt 24 1372 N 23008 3,0 Watt 24 1568 N 23008 5,0 Watt 24 1764 N - * finishing observe protection IP 40 DIN 40050 Y1 Floor mounting Wall mounting X1 Y2 X2 Project work for floor mounting Typ magnet length length with length with mm armature.. R005 armature.. R006 Standard mm mm Y1/Y2 Z Z Serien 60 GT50R060.01 120 108 140 GT70R060.01 120 121 151 Project work for wall mounting Typ length length with length with magnet armature.. R005 armature.. R006 mm mm mm Standard X1 X2 Serien 90 GT50R091.01 38 56 88 GT50R092.01 38 56 88 Serien 89 GT50R089.01 150 118 151 GT50R089.01 300 118 151 GT50R089.01 450 118 151 We can deliver suitable current power unit equipment (VdS permitted). For the explosion proof magnets they must be installed outside of incompatible rooms. According DIN VDE 0580 July 2000 ICS 29.020.53.020.01 (manufacture attestation of conformity). Art. 10 of recommandation 73/23/EWG according CENELEC-Memorandum Nr.3 issue 1990/12. The product should only be used for the range of application. An applicate measure of security and EMV must be safed before initation by the plan. You must accomplish maintenance in frame of prescribeded examination and observe assemmbly direction of the installation instruction. Kendrion Magnettechnik GmbH Werk Donaueschingen August-Fischbach-Straße 1 D-78166 Donaueschingen Tel. +49 (0)771 8009-0 Fax +49 (0)771 8009-634 Serien 89 GT50R089.01 185 203 235 GT50R089.01 335 353 385 GT50R089.01 485 503 535 Kendrion Magnettechnik GmbH Werk Engelswies Fred-Hahn-Straße 33 D-72514 Inzigkofen-Engelswies Tel. +49 (0)7575 208-0 Fax +49 (0)7575 208-190 03/03 Kendrion Magnettechnik GmbH Printed in Germany KMT - 002/0303/2./1/E - MD www.kendrionmt.com info@kendrionmt.com Construction change expected