Elbtalwerk GmbH. Universität Karlsruhe Elektrotechnisches Institut. Switched Reluctance Motor. Compact High-torque Electric Motor. Current.

Similar documents
Technical Guide No. 7. Dimensioning of a Drive system

EXPERIMENTAL VERIFICATION OF INDUCED VOLTAGE SELF- EXCITATION OF A SWITCHED RELUCTANCE GENERATOR

CHAPTER 3 DESIGN OF THE LIMITED ANGLE BRUSHLESS TORQUE MOTOR

Unit Protection System for Pumped-Storage Power Stations

Synchronous Motor Drives

Technical Explanation for Inverters

Part- A Objective Questions (10X1=10 Marks)

Doubly fed electric machine

Quantum Series Size 17, 23, 34 and 56 Brushless Servo Motors Frameless and Housed Engineering Guide

SECTION 4 ELECTRIC MOTORS UNIT 17: TYPES OF ELECTRIC MOTORS UNIT OBJECTIVES UNIT OBJECTIVES 3/21/2012

EEE3441 Electrical Machines Department of Electrical Engineering. Lecture. Introduction to Electrical Machines

Single Phase Induction Motors

The Advantages of Linear Direct Drives

9. Examples of hydro energy conversion

COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING QUESTION BANK SUBJECT CODE & NAME : EE 1001 SPECIAL ELECTRICAL MACHINES

Prepared By: Ahmad Firdaus Bin Ahmad Zaidi

Planning and Commissioning Guideline for NORD IE4 Motors with NORD Frequency Inverters

Electromagnetic clutches and brakes INTORQ and INTORQ

COMBIBOX. Program Schedule. Design. COMBIBOX clutch-brake-combination type 10 / 09 / 06. Attachments

Chapter 3.2: Electric Motors

INTRODUCTION. I.1 - Historical review.

Sensorless Brushless DC-Servomotors

CHAPTER 4 MODELING OF PERMANENT MAGNET SYNCHRONOUS GENERATOR BASED WIND ENERGY CONVERSION SYSTEM

EC Motors, the extended arm of automotive electronics

Full Voltage Starting (Number of Starts):

Electromagnetic tooth clutch Type 546

QUESTION BANK SPECIAL ELECTRICAL MACHINES

Demag KB conical-rotor brake motors. Drives with unique principle

Código de rotor bloqueado Rotor bloqueado, Letra de código. Rotor bloqueado, Letra de código

Step Motor Lower-Loss Technology An Update

Permanent-magnet synchronous motors

Lower-Loss Technology

CHAPTER THREE DC MOTOR OVERVIEW AND MATHEMATICAL MODEL

MANTECH ELECTRONICS. Stepper Motors. Basics on Stepper Motors I. STEPPER MOTOR SYSTEMS OVERVIEW 2. STEPPING MOTORS

Aspects of Permanent Magnet Machine Design

Measuring equipment for the development of efficient drive trains using sensor telemetry in the 200 C range

COMPARING SLOTTED vs. SLOTLESS BRUSHLESS DC MOTORS

DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING

Planning and Commissioning Guideline for NORD IE4 Synchronous Motors with NORD Frequency Inverters

Asynchronous generators

Data Sheet. Size 1 and 2 Stepper Motors. 7.5 stepper motors Size 1 (RS stock no ) Size 2 (RS stock no ) Data Pack B

Lab Electrical Power Engineering I

Asynchronous and synchronous motors for SINAMICS S120 1PL6 asynchronous motors Forced ventilation, IP23 degree of protection

R13 SET - 1. b) Describe different braking methods employed for electrical motors. [8M]

AC Synchronous Reluctance motors

PAC TRAINING PUMP MOTORS

Catalog Mars Low voltage Brake motors

PHY 152 (ELECTRICITY AND MAGNETISM)

Mechatronics and Electrical Drives

10. Starting Method for Induction Motors

Introduction. 1/2 Overview 1/3 Benefits 1/3 Application. 1/3 Order No. code. 1/4 Protection strategy

Synchronous motors. Main spindle motors for SINAMICS S120 1FE1 standard type built-in motors Water cooling. 6/86 Siemens NC /2008

COMBIBOX Program Schedule. Design. COMBIBOX Clutch-brake-combination type 10 / 09 / 06. Attachments input

COMBIBOX. Program Schedule. with an energised to engage single sided clutch without brake... COMBIBOX 09

Step Motor. Mechatronics Device Report Yisheng Zhang 04/02/03. What Is A Step Motor?

Permanent magnet brakes. Safety from the market leader. PM Line High Torque Line

Design of Brushless Permanent-Magnet Machines. J.R. Hendershot Jr. T.J.E. Miller

2. Draw the speed-torque characteristics of dc shunt motor and series motor. (May2013) (May 2014)

Electric Machines CHARLES A. GROSS. Aubum University Auburn, Alabama, U.S.A. LßP) CRC Press Vv* / Taylor & Francis Croup. Boca Raton London New York

DESIGN OF COMPACT PERMANENT-MAGNET SYNCHRONOUS MOTORS WITH CONCENTRATED WINDINGS

A.C. Motor for Railway. Auxiliary Application

AC dynamometer parameter download

Chapter 5: DC Motors. 9/18/2003 Electromechanical Dynamics 1

Linear Drive with Ball Screw Drive Series OSP-E..SB

General Purpose Permanent Magnet Motor Drive without Speed and Position Sensor

POWER SUPPLY FOR ASYNCHRONOUS MOTORS

DHANALAKSHMI SRINIVASAN COLLEGE OF ENGINEERING AND TECHNOLOGY MAMALLAPURAM, CHENNAI

CHAPTER 5 FAULT AND HARMONIC ANALYSIS USING PV ARRAY BASED STATCOM

Synchronous Generators I. Spring 2013

gear reduction. motor model number is determined by the following: O: Single 1: Double Motor Characteristics (1-99) Construction

Electrical Machines -II

The instantaneous torque is pulsating. The average value of the torque is

Linear Actuator with Ball Screw Series OSP-E..S. Contents Description Overview Technical Data Dimensions 89

CPLS Asynchronous motors for variable frequency. 95 Nm to 2900 Nm

QMOT Motor QSH4218 Manual 42mm QMOT motor family

1/7. The series hybrid permits the internal combustion engine to operate at optimal speed for any given power requirement.

Principles of Electrical Engineering

Linear Drive with Toothed Belt Series OSP-E..B. Contents Description Overview Technical Data Dimensions Order Instructions 46

Synchronous Generators I. EE 340 Spring 2011

ECEg439:-Electrical Machine II

Motors- Basic principles. Expertise, performance, innovation

Tips & Technology For Bosch business partners

St.MARTIN S ENGINEERING COLLEGE Dhulapally, Secunderabad

Question Bank ( ODD)

SINAMICS SM150. 4/2 Overview. 4/2 Benefits. 4/2 Design. 4/6 Function. 4/8 Selection and ordering data. 4/8 Options

Technology Trends in emotor Components for Automotive Applications. Mateo Primorac , Miba AG

BHARAT ALUMINIUM COMPANY LTD. SPECIFICATIONS FOR SYNCHRONOUS GENERATOR GENERAL Make : Jinan Power Equipment Factory Type : WX2

9.9 Light Chopper Drive Motor

DEPARTMENT OF EI ELECTRICAL MACHINE ASSIGNMENT 1

Asynchronous motors. 5 Asynchronous motors 5/2 Type overview and rated data 5/4 Technical definitions 5/4 Encoder systems

HBI 22. Integrated Three-phase Synchronous Drive

INTRODUCTION Principle

DYNEO VARIABLE SPEED DRIVES Unidrive SP variable speed drives LSRPM - PLSRPM permanent magnet synchronous motors

Permanent Magnet Synchronous Motor. High Efficiency Industrial Motors

ELG4125: Flexible AC Transmission Systems (FACTS)

hofer powertrain GmbH

AXIAL FLUX PERMANENT MAGNET BRUSHLESS MACHINES

QMOT STEPPER MOTORS MOTORS

The D series CONTENTS. the single-cylinder diesel engine with revolutionary technology 4. -SILENT PACK environmentally friendly perspectives 5

The right twist for your machine. Torque motors 1FW6

Transcription:

Elbtalwerk GmbH Switched Reluctance Motor Compact High-torque Electric Motor Current B1 Winding A1 D4 C1 C4 Pole D1 Rotation B4 A2 Rotor tooth Shaft A4 B2 Field line D3 C2 C3 D2 Stator A3 B3 Cooling air duct Universität Karlsruhe Elektrotechnisches Institut

Applications The switched reluctance motor is suitable for use in variable-speed and positioning drive units. Depending on the converter design two-quadrant or four-quadrant operation is possible. Advantages of this motor over other drives: above-average continuous torque in the base speed range extraordinary acceleration capability low maintenance high holding torque even over extended periods high overload capability small dimensions high operating safety after failure of one or several motor phases excellent efficiency over wide speed range ruggedness negligible rotor temperature rise in lower speed range. Switched reluctance drives are beneficial for applications where one or several of these properties are required. Owing to the optimum cross-section chosen, the noise emission of the switched reluctance motor developed by us is non-critical at any operating points in the lower speed range. Maximum speeds: As the rotor of the switched reluctance motor has no winding and no permanent magnets, it may be subjected to high radial forces which makes the motor ideal for high-speed applications. Since the hysteresis loss rises as the speed increases, low-pole reluctance motors are the best choice for these applications. 2

Operating principle The operating principle of the switched reluctance motor is quite easy: A rotatable iron rod or the iron teeth of a machine rotor aligns itself with the magnetic field generated by the electric current flowing in a stator pole. By a continuous travelling, or rotation, of the magnetic field the iron rod or rotor is forced to co-rotate. If this rotor has several teeth, its shape is comparable with a long-streched-out toothed wheel. The term reluctance stands for the magnetic resistance such a rotor offers to the electromagnetic field. The magnetic field is generated and caused to rotate by the stator pole windings and an electronic power component upstream of the motor. The electronic component, which is a power or frequency converter, serves the adjustment of the speed and torque of the switched reluctance motor. Switched reluctance motors can be designed in the wide range from miniature motors to largescale units. Model drives Two switched reluctance motors of a rated power output of 18.5 kw and 23.5 kw, respectively, and a speed of 1,5 rpm were designed, optimized and tested at the Electrical Engineering Institute of the University of Karlsruhe. The converter was directly connected to a 4V/5Hz three-phase system. Below some results obtained in the tests of these motors will be looked into in more detail; they exemplify the performance of the switched reluctance motors. The operating principle and cross-section of the newly developed switched reluctance motor are shown on the cover sheet. The motor has 16 salient stator poles and 12 rotor teeth. 3

Low moment of inertia - high dynamic performance Owing to the mass-free gaps between the teeth on the outer surface of the rotor, the switched reluctance motor has a very low moment of inertia. The rotor consists only of the laminated core and the shaft, i.e. it has no winding and no permanent magnets. Table 1 compares the moments of inertia of a standard asynchronous motor, a three-phase asynchronous machine optimized for highly dynamic applications, and a switched reluctance motor. The advantages of the latter over the other machines are obvious. As to the nominal working point, insulation class and cooling system, the technical data of the three motors are comparable. Switched Reluctance Asynchronous Motor Asynchronous Motor Motor (optimized size) (standard) MFR 132.5 ACHA 132.5 Moment of.883 kgm 2.15 kgm 2.15 kgm 2 inertia 59% 7% 1% Table 1: Moments of inertia Better utilization at low speeds The iron losses of switched reluctance motors, unlike those of asynchronous motors, make up a conciderable portion of the total losses. However, the iron losses drop heavily as the speed is reduced. This effect is made use of to increase the rms currents in the pole windings and to obtain a high permissible continuous torque in the lower speed range. Moreover, operating the machine at low speeds results in low rotor iron losses - consequently, the rotor temperature rise remains low. In asynchronous motors, the stator and rotor winding losses make up the largest portion of the total losses which remain almost constant from standstill to rated speed if the torque is assumed to be constant. This explains why asynchronous 4

motors, when operated in continuous duty, must not be subjected to a torque higher than the nominal torque until the rated speed is reached. Field weakening operation begins for all three motors when the rated speed is exceeded. In Figure 1, the maximum permissible continuous torque, referred to the moment of inertia, is shown in the speed range from above to 1,5 r.p.m. for the use of insulation class F. Figure 1 characterizes the acceleration capability and the utilization of the machines in continuous duty. The two reluctance motors differ only in the quality of the electric sheet steel used. In continuous duty, the maximum permissible holding torque of the 18.5 kw reluctance motor amounts to 145% of the rated torque when the motor is at rest. As soon as the rotor starts to rotate, however, all pole windings are subjected to the same thermal loads, and the continuous torque may be 19% of the rated torque at low speeds. For dynamic transient processes in the base speed range, the motors may be subjected to two to three times the rated torque. Continuous torque / moment of inertia [Nm/kgm 2 ] 25 225 2 175 15 125 1 75 5 25 switched reluctance motor MFR 132.5 (18.5 kw) switched reluctance motor MFR 132.5 (23.5 kw) asynchronus motor ACHA 132.5, optimized (22 kw) asynchronus motor, standard (22 kw) 25 5 75 1 125 15 Speed [r.p.m.] Figure 1 Permissible continuous torque referred to the moment of inertia for use of insulation class F (measured) 5

The curves and values for the type ACHA 132.5 asynchronous machines are those of the manufacturer s data sheet [1]. The unit volume, size, outer dimensions and core assembly length of the optimized asynchronous motor ACHA 132.5 are identical with those of the switched reluctance motor MFR 132.5. Much better efficiency at speeds below rated speed At the nominal working point, the efficiency of the switched reluctance motor is that common for a three-phase motor of this performance class. In the lower speed range, however, the efficiency of the reluctance motor drops insignificantly (Figure 2). With the motor at nominal torque, the efficiency raises to above 8% as from 3 r.p.m., and gradually increases further to approx. 9% until rated speed is reached - another advantage of this kind of drive. At the nominal working point, the efficiency of the 23.5 kw switched reluctance motor is 91.1%. Efficiency [%] 1 9 8 7 6 5 4 3 2 1 25 5 75 1 125 15 Speed [r.p.m.] Figure 2 Efficiency of the 18.5 kw switched reluctance motor at nominal torque and variable speed (measured) 6

Variable-speed drives The speed control circuit of the switched reluctance motor has been designed as is common in the field, and has been optimized to compensate speed variations. A ramp-function generator ensures that an overshooting of the actual speed is almost entirely compensated when a setpoint step-change occurs. Figure 3 shows the response to setpoint changes during acceleration to rated speed. The drive accelerates at a torque of approx. 17 Nm. The inertia of the driven machine used for the measurements is five times that of the reluctance motor. The resultant acceleration time is 63 ms. Speed [r.p.m.] 15 n act n ramp-function gen. 1 5 n ramp-function n act 1 2 3 4 5 6 7 8 9 1 Time [ms] Figure 3 Acceleration from standstill to rated speed J total =.54 kgm 2 (measured) 7

Figure 4 shows the disturbance behaviour of the implemented speed control circuit as verified in measurements. At a load step-change from 1 Nm to 11 Nm, the speed remains within a tolerance band of 3%. After 25 ms the speed has returned to its stationary value of 1, rpm. The rate of load torque rise is given by the coupled DC machine. Speed [r.p.m] 12 1 8 6 4 2 1 2 3 4 5 6 7 8 Time [ms] Figure 4 Speed behaviour after a torque rise of 1 Nm J total =.54 kgm 2 (measured) 8

Use for positioning purposes Among the tasks electric motors are used for are also positioning tasks, e.g. the positioning of workpieces and tools, the displacing of machine parts or the hoisting of cages. Basically, switched reluctance motors can also be used for such applications. Figure 5 shows the transient response following a 18 change of position. The rotor rotates through 18, and the required setpoint value is reached after approx. 6 ms. With many positioning tasks, such as position changes in machine tools, an overshooting of the end position is impermissible. The position control parameters have been chosen so as to meet this requirement. Position [ ] 15 1 5 Torque [Nm] 1-1 Speed [r.p.m] 2 1 1 2 3 4 5 Time [ms] Figure 5 Change of position through 18 J total =.54 kgm 2 (measured) 9

High operating safety after phase failure The switched reluctance motor is characterized by a high operating safety after the failure of one or several motor phases. When such a failure occurs, the motor continues to run under load, and it can be accelerated or braked (Figure 6). However, the torque and speed fluctuations occurring are of a measurable magnitude, and the start-up of the motor is no longer ensured. Despite this drawback, the driven machine, or process under way, can be set back into a safe state in many an application. Speed [r.p.m] 45 4 35 3 25 n ramp-function gen. 2 15 n act. 1 5 1 2 3 4 5 6 7 8 9 1 Time [ms] Figure 6 Change of speed upon failure of two motor phases M load = 5 Nm, J total =.54 kgm 2 (measured) Here, too, the ramp-function generator prevents the speed setpoint step-change from being directly injected to the setpoint/actual-value comparator of the speed controller. 1

Mains compatibility of model drive The line current converter is a three-phase transistorized converter. Line current control has been optimized so that the drive, when in steady-state operation, draws energy from, or feeds energy to, the three-phase system at cos ϕ =1 and a power factor of approx. 1. This means a sine-wave line current and coincidence of the current and voltage phase angles - or, in brief, good compability of the drive with the mains. Figure 7 shows the voltage and current of a phase upon a load change of the reluctance motor from approx. 18 kw generator operation to 18 kw motor operation. The line current converter allows four-quadrant operation and thus highly dynamic drive solutions to be implemented. If the converter is used for the main drive of a group of drives, for example, it may be additionally employed for compensating the reactive power of the auxiliary drives. For reluctance drives less demanding in terms of dynamics and mains compatibility, rectifier bridges with smoothing and commutating reactors are used as line current converters. 4 Line-to-neutral [V] 3 2 1-1 -2-3 -4.1.2.3.4.5.6.7.8.9.1 4 Phase current [A] 3 2 1-1 -2-3 -4.1.2.3.4.5.6.7.8.9.1 Time [s] Figure 7 Line voltage and line current upon load change from 18 kw generator operation to 18 kw motor operation (measured) 11

Reference: [1] Data sheet, three-phase main drives, Elbtalwerk GmbH Author: J. Wolff University of Karlsruhe Elektrotechnisches Institut Kaiserstrasse 12 D-76128 Karlsruhe Germany Manufacturer: Elbtalwerk GmbH Fritz-Schreiter-Strasse 31 D-1259 Dresden Germany phon: (+49 351) 2425 fax: (+49 351) 242555 12