RadioTouch Controller for Lights, Sivoia QED Controllable Window Shading System, and Contact Closures and -347 Description The RadioTouch lights, Sivoia QED ultra-quiet controllable window shading system, and contact closure controller is designed to work in conjunction with RadioTouch transmitters that have been addressed to the controller. The controller can be addressed to respond to signals from up to 16 RadioTouch transmitters. The controller has the ability to control Lutron Hi-lume and ECO-10TM s directly. The controller can be connected to a Lutron FDI to dim Lutron Tu-wireTM s, incandescent, magnetic low-voltage, and electronic low-voltage loads. The controller mounts to a standard 4 x 4 inch (120 x 120 mm) junction box or to the knockout of a fluorescent fixture. The controller can directly accept inputs from standard 15 and 24 occupant sensors as well as Lutron s MW-PS-WH and MW- FPS-WH daylight sensors. The controller operates at either 120/277 or 347, depending on the model number. The controller can communicate with Lutron s Sivoia QED ultra-quiet controllable window shading system through a SQ-CCI-8. It also has the ability to provide up to five momentary dry contact closures, and control AC shade and projection screen motors through a group control. CFIGURACIES PEL (Class 2: USA) 6 7 8 9 10 11 12 13 14 15 16 24 P/N 50634 ' 2006 Lutron Electronics Co., Inc. Ratings Model Number oltage Maximum Current Switch Closure Maximums 120 or 277 16 A (20 A breaker) 30 1/3 A -347 347 16 A (20 A breaker) 30 1/3 A
6 7 8 9 10 11 12 13 14 15 16 Dimensions and -347 Features Dimensions are in inches (mm). CFIGURACIES PEL (Class 2: USA) TX 6 7 8 9 10 11 12 13 14 15 16 24 RX 4.0 (100) Mounting P/N 50634 ' 2006 Lutron Electronics Co., Inc. 7.75 (197) 2.5 (63.5) Using two screws, mount the unit to a 4 x 4 inch (120 x 120 mm) junction box or directly to a wall (screws and wall anchors are provided) as shown. Provides direct control of a full circuit of Lutron Hi-lume and ECO-10TM s. Capable of switching 16 A of Lutron s. Provides control of Lutron Tu-wireTM s, incandescent, magnetic low-voltage, and electronic low-voltage loads using an FDI load. operates at 120 or 277 line voltage. -347 operates at 347 line voltage. Each controller can be programmed to accept control information from 16 unique RadioTouch transmitters. Accepts inputs from standard 15 and 24 occupant sensors and provides power to them (not to exceed 30 ma). One required per lighting zone to be controlled. Accepts an input from a Lutron MW-PS-WH or MW-FPS-WH daylight sensor to regulate the electric light based on the presence or absence of sunlight and provides power to the sensor (not to exceed 30 ma). Accepts control signals from RadioTouch transmitters at 418 MHz. Provides a burn-in function to assist in the seasoning of new fluorescent bulbs for 100 hours. Mounts to a standard 4 x 4 inch (120 x 120 mm) junction box or to the knockout of a fluorescent fixture. Provides up to five momentary dry low-voltage contact closures. Communicates with Lutron s Sivoia QED ultraquiet controllable window treatments through contact closure outputs and a SQ-CCI-8 Sivoia QED. Requires a group control to operate AC shades and projection screen motors.
LISTED LISTED 243C 243C Refer Refer to the to the Installers Installers Guide Guide for more for more detailed Consulte Consulte la Guía la Guía de Instaladores de Instaladores para para información información más más detallada. Mexico detallada. 1-888-235-2910 Référer Référer au Guide au Guide d installation d installation pour pour plus plus de de renseignements détaillés. CFIGURACIES CFIGURACIES PWR STAT PROG 100 Hr/100 6 7 8 9 10 11 12 13 14 15 16 6 7 8 24 24 and -347 Power Wiring Diagram (120 ) /Red Red (277/347 ) Cap the wire that is not being used (red or black, depending on voltage) PEL PEL (Class 2: 2: USA) Occ. Com Occ. S ig PS S ig P/N 50634 ' 2006 Lutron Electronics Co., Inc. P/N 50633 2006 Lutron Electronics Co., Inc. Switched (blue) Dimmed (orange) ECO dimming ECO dimming To additional dimming s
CFIGURACIES 6 7 8 9 10 11 12 13 14 15 16 24 Dimmable Zone Controllers and -347 rta-rx-f 4 04.15.09 Lutron olt Ballast and Control Wiring Note: Lamp wires not shown, but must be in place and correct for proper operation. Do not connect more than 40 s to a single controller. (120 ~) /Red Red (277 / 347 ) Cap the wire that is not being used (red or black, depending on voltage) PEL (Class 2: USA) - Gray + Purple P/N 50634 ' 2006 Lutron Electronics Co., Inc. PEL (Class 2: USA) wiring Switched (blue) Gray Purple Gray Purple To additional dimming s Lutron dimming Lutron dimming
CFIGURACIES 6 7 8 9 10 11 12 13 14 15 16 24 CFIGURACIES 6 7 8 9 10 11 12 13 14 15 16 24 Wiring Multiple Dimming Zones and -347 rta-rx-f 5 04.15.09 Danger! Locate and lock the supply breaker in the Off position, or remove the supply fuse before continuing. (120 ) /Red Red (277 / 347 ) Cap the wire that is not being used (red or black, depending on voltage) Switched (blue) Dimmed (orange) Warning! Total load cannot exceed the breaker limit of the distribution panel. Hi-Lume FDB or Eco-10TM Ballast and Control Wiring (Multiple Lighting Zones) To additional lighting zones (120 ) /Red PEL (Class 2: USA) PEL (Class 2: USA) Red (277 / 347 ) Cap the wire that is not being used (red or black, depending on voltage) P/N 50634 ' 2006 Lutron Electronics Co., Inc. P/N 50634 ' 2006 Lutron Electronics Co., Inc. Switched (blue) Dimmed (orange) To additional dimming s To additional dimming s
CFIGURACIES 6 7 8 9 10 11 12 13 14 15 16 24 CFIGURACIES 6 7 8 9 10 11 12 13 14 15 16 24 and -347 Wiring the Controller with an Interface Turn Power Off. When using load s, it may be necessary to adjust the preset light levels prior to use. (See Adjust Preset Levels on page 36 after completing wiring.) Remove the bypass wiring connections previously made. Connect the input feed wires and the output load wires as indicated by the wiring diagrams below. Danger! Locate and lock the supply breaker in the Off position, or remove the supply fuse before continuing. Caution! The FDI-FTU-16A-120, FDI-EL-1000, and FDI-INC-2000 operate on 120 only. Ballast and Control Wiring Using the Tu-Wire Interface (FDI-FTU-16A-120) (120 ) Red (277 / 347 ) /Red PEL (Class 2: USA) P/N 50634 ' 2006 Lutron Electronics Co., Inc. (control input) Blue DO NOT WI RE LIE! To additional dimming s COOPERSBURG, PA USA Dimmed hot output FDI-FTU-16A-120 Tu-Wire Tu-Wire dimming Tu-Wire dimming Ballast and Control Wiring Using the Incandescent/Magnetic Low-oltage Interface (FDI-INC-2000) or Electronic Low-oltage Interface (FDI-EL-1000) (120 ) /Red Red (277 / 347 ) PEL (Class 2: USA) P/N 50634 ' 2006 Lutron Electronics Co., Inc. Blue DO NOT WI RE LIE! COOPERSBURG, P A USA Dimmed hot output FDI-INC-2000 incandescent/ magnetic lowvoltage or FDI-EL-1000 electronic lowvoltage To additional light fixtures Incandescent bulb or low-voltage transformer if ML or EL Incandescent bulb or low-voltage transformer if ML or EL
CFIGURACIES 6 7 8 9 10 11 12 13 14 15 16 6 7 8 9 10 11 12 13 14 15 16 1 2 3 4 COMM COMM COMM COMM COMM COMM COMM COMM OPTIS PR OGRAM STATUS POWER OPEN ALL CLOSE ALL OPEN 4 CLOSE 4 OPEN 3 CLOSE 3 OPEN 2 CLOSE 2 OPEN 1 CLOSE 1 and -347 System Wiring Requirements Review system wiring requirements and ensure proper wires are pulled for hardware installation. Each zone of lighting requires a RadioTouch controller. Notes Observe all local and national electrical codes and safety standards. The maximum total wire length for the load circuit is 250 feet (91 m). Either an AC motor or a Sivoia QED contact closure can be d to a single controller, but not both. Dimmed hot Switched hot Distribution panel (not included) PEL (Class 2: USA) 24 P/N 50634 2006 Lutron Electronics Co., Inc. Line voltage wiring Cap the wire not being used (depending on input voltage) Line voltage wiring PEL (Class 2: USA) wiring #18 AWG (1.0 mm 2 ) Additional for 4-lamp fixtures only Shades Lights 2 Lights 1 To other fluorescent fixtures Tabletop transmitter Line voltage in AC motorized projection screen(s) or AC motorized window treatment(s) Lutron AC motor controller OR RTA- SCI Wallbox transmitter Lutron Sivoia QED contact closure Lutron Sivoia QED shade(s) 18 RTA- RS232 Occupant sensor LUTR Daylight sensor 9 Momentary dry contact closure inputs (from others) RS232 (from others)