GP Dimming Panels. GRAFIK Systems SPECIFICATION SUBMITTAL
|
|
- Florence Watts
- 6 years ago
- Views:
Transcription
1 rev gp-a GP3/4 Mini Panels GP8-4 Standard-Size Panels DESCRIPTION Provide power and dimming for up to 44 load circuits. Control any light source, including full-conduction non-dim. Models available for: 00-7V, 0-40V (non CE), 30V (CE), and 77V. 3 to 44 circuits. Different feed types and breakers. work with: GRX-4000 Control Units GRAFIK 5000 and 6000 Systems LP Dimming Panels XP SoftswitchTM Panels DMX5 dimming systems via the LINKTM option. Get a Panel Fast! LISA (Lutron Integrated System Advantage) Program ships standard Panels 3 to 5 working days from receipt of approved drawings. GP36 Large-Size Panels GP48-44 Large-Size Panels
2 rev gp-a SPECIFICATIONS Standards UL Listed (Reference: UL File 407). Complies with ISO-9000, CSA, NOM, or CE (where appropriate). Power Input power: 00-7V, 0-40V (non CE), 30V (CE), and 77V. All voltages 50/60Hz, phase-to-neutral. Branch Breakers: UL-rated thermal magnetic. Protected by bypass jumpers. AIC ratings: 00-7V 0, V V (CE) 5,000 77V 4,000 Lighting strike protection: Meets ANSI/IEEE standard Can withstand voltage surges of up to 6000V and current surges of up to 3000A. 0-year power failure memory: Automatically restores lighting to scene selected prior to power interruption. Sources/Load Types Operates these sources with a smooth continuous Square Law dimming curve or on a full conduction non-dim basis: Incandescent (Halogen)/Tungsten Magnetic Low Voltage Transformer Electronic Low Voltage Transformer Lutron Electronic Fluorescent Dimming Ballasts Magnetic Fluorescent Lamp Ballasts Operates HID sources on a full conduction non-dim basis. Reverse-phase control transformers require an ELVI Power Interface. Check phase with transformer manufacturer. Dimming Cards 6A continuous rating. UL-listed specifically for each light source. RTISSTM filter circuit technology compensates for incoming line voltage variations: No visible flicker with +/-% change in RMS voltage/cycle and +/-% Hz change in frequency/second. Arcless-relay air gap-off switches (one per load circuit): Ensure open load circuits when off function selected from Wallstations or Control Units. Eliminate arcing at mechanical contacts when loads are switched. Filter chokes Provide a rise time of at least: 350µSec as measured 0-90% of load current waveform at 50% dimmer capacity 55µSec as measured 0-00% of load current waveform at 50% dimmer capacity 400µSec as measured 0-90% of load current waveform at 00% dimmer capacity 600µSec as measured 0-00% of load current waveform at 00% dimmer capacity All measurements are recorded at a 90 degree conduction angle. At no point in the waveform can the rise time slope exceed a rate of 300mA per µsec. WHAT A MODEL NUMBER TELLS YOU Standard Prefix for GP Dimming Panels Feed Type for Ø, W 3 for Ø, 3W 4 for 3Ø, 4W Branch Breaker Number of amps Internal: Prewired by Lutron. System communications: Low-voltage Class (PELV) wiring connects Dimming Panels to other components. Line (mains) voltage: Feed, load, and control circuit wiring only. No other wiring or assembly required. Setup selector electronically assigns circuits to zones and sources. Permits reassignment of zones and sources without rewiring. Physical Design Enclosure: NEMA-Type, IP-0 protection; #6 U.S. Gauge Steel. Indoors only. Weight: pounds (4-590kg). Mounting: Surface mount only. Allow space for ventilating. Environment/Heat Dissipation Patented, ribbed aluminum heat sink base cools Panel by convection. No fans F (0-40 C). Relative humidity less than 90% non-condensing. Region Suffix no code for 00-7V AU for 0-40V CE for 30V JA for 00V G P I S A U C G P - Number of Load s Voltage 0 for for non CE 30 for CE 77 Panel Breaker ML for Main Lugs Only Mxx for Main Breaker with xx = breaker size in amps IS for Isolator Switch Custom Panel Suffix shows that this Panel includes special options
3 rev gp-3a GP3/4 MINI MODELS Only standard Panels listed. Consult Lutron for options. 00-7V Power GP 3 GP 4 MODELS AVAILABLE FOR... NUMBER OF MAXIMUM PANEL FEED/BRANCH CIRCUITS FEED TYPE FEED CIRCUIT BREAKERS Ø, W 45A 5A 60A 0A Ø, 3W 3Ø, 4W 30A 40A 5A 0A 5A 0A 5A 0A Feed 0A 5A Through 0A 0A 77V Power GP 3 GP 4 MODELS AVAILABLE FOR... NUMBER OF MAXIMUM PANEL FEED/BRANCH CIRCUITS FEED TYPE FEED CIRCUIT BREAKERS Ø, W 60A 3Ø, 4W 0A Feed Through 0A 0A 0A 30V (CE) Power GP 3 GP 4 MODELS AVAILABLE FOR... NUMBER OF MAXIMUM PANEL FEED/BRANCH CIRCUITS FEED TYPE FEED CIRCUIT BREAKERS Ø, W 30A 3Ø, 4W 0A Feed Through 0A 0A 0A 0-40V (non CE) Power GP 3 GP 4 MODELS AVAILABLE FOR... NUMBER OF MAXIMUM PANEL FEED/BRANCH CIRCUITS FEED TYPE FEED CIRCUIT BREAKERS Ø, W 48A 3Ø, 4W 6A Feed Through 0/6A, 5/A continuous load rating. Breakers located in distribution panel supplied by others. 6A 6A 6A WIRE SIZES GP 3 Feed Power (Hot/Live) wires connect directly to Branch Breakers: 00-7V 77V 0-40V 30V (CE) #4 AWG (.0mm ) to #0 AWG (4.0mm ) #8 AWG (.0mm ) to #4 AWG (5mm ) 30V (CE) MAINS CE Panels are listed as appliances. Distribution Panel must provide a main circuit breaker that does not exceed Panel Rating. Neutral wire connects to Neutral Lug: #4 AWG (.0mm ) to #8 AWG (6.0mm ) GP 4 Feed Through Power (Hot/Live) and Neutral connect to Terminal Blocks #4 AWG (.0mm ) to #0 AWG (4.0mm ) GP 3/4 Load Connect to Terminal Blocks #4 AWG (.0mm ) to #0 AWG (4.0mm )
4 rev gp-7a DIMENSIONS FOR GP3/4 MINI PANELS Top View 5 /8" (30mm) 3 5/8" (9mm) 6 /4" (60mm) 5/8" (4mm) Class (PELV) Left Side View Front View 9 5/8" (44mm) 3/6" (8mm) Right Side View 5 /4" (30mm) 8" (457mm) 9 /" (495mm) /8" (537mm) /8" (9mm) /8" (9mm) 3/4" (70mm) " (79mm) Bottom View Keyhole accepts a maximum of /4" (6mm) mounting bolt. #0 M6 recommended. 3/4" (70mm) Load 3/4" (70mm) /" (38mm) 5 /" (40mm) /" (38mm) Feed
5 rev gp-a MOUNTING FOR GP3/4 MINI PANELS Surface mount indoors. Panel generates heat! Mount only where ambient temperature is 3-04 F (0-40 C). This equipment is air-cooled. Do not block vents or you will void the warranty. Leave " (3cm) clearances above, below, and in front of Panel. No clearance necessary on sides. Reinforce wall structure for weight and local codes. GP3/4 Front View Class (PELV) GP3/4 Side View " (3cm) minimum top and front PANEL MAXIMUM WEIGHT BTUs/HOUR (WITHOUT PACKAGING) GP3/ lbs (4kg) Terminal Blocks for Load s Branch Breakers Mount Panels where audible noise is acceptable. (Panels hum slightly and internal relays click.) Mount Panels so line (mains) voltage wiring is at least 6 feet (.8m) from sound or electronic equipment and wiring. Mount Panel within 7 of true vertical. Load Feed Raceway " (3cm) minimum Maximum Feed and Wire Sizes Consult Overview page. Water damages Panels! Install Panels in a location where they won't get wet.
6 rev gp-6a GP3 MINI WIRING OVERVIEW Control Typical Load Bypass Jumpers! Do Not Remove DH SH H DH SH H DH 3 SH 3 H 3 Branch Breakers Dimmed Hot/Live Neutral Load Terminal Block () #4 AWG (.0mm ) to #0 AWG (4.0mm ) () #4 AWG (.0mm ) to #0 AWG (4.0mm ) Neutral Lug Feed Tips! You wire the GP3 Mini similar to wiring a lighting Distribution Panel. You run feed and load wiring. No other wiring or assembly required. You can use the GP3 Mini to provide temporary lighting. Wire all loads. Do not remove the bypass jumpers that protect the Dimming Modules. Use Branch Breakers to switch lights on and off. Neutral 00-7V #4 AWG (.0mm ) to #/0 AWG (70mm ) 0-40V #4 AWG (.0mm ) to 30V (CE) #8 AWG (6.0mm ) Power (Hot/Live) 00-7V #4 AWG (.0mm ) to #0 AWG (4.0mm ) 0-40V #8 AWG (.0mm ) to 30V (CE) #4 AWG (5mm )
7 rev gp-0a V AND 77V LOAD CIRCUITS (GP3-44) All Load Types except Lutron Hi-lume or Eco-0TM (ECO-Series) Fluorescent Dimming Ballasts GP Dimming Panel N Neutral (White) Use Dimmed Hot (DH) for all loads including Non-Dim. Use Switched Hot (SH) only with Lutron Fluorescent Dimming Ballasts. Dimmed Hot (Orange) DH SH H Load All Load #4 AWG (.0mm ) to #0 AWG (4.0mm ) Bypass Jumper! Do Not Remove Load Terminals Lutron Hi-lume or Eco-0 (ECO-Series) Fluorescent Dimming Ballasts GP Dimming Panel Where Neutral is Located Consult Overview page for the type of panel your working on. N Neutral (White) Red Load Dimmed Hot (Orange) Switched Hot (Black) Hi-Lume or Eco-0 (ECO) Ballast Red Blue Blue DH SH H Ground Load Terminals Load s with Emergency Battery Pack GP Dimming Panel Consult Lutron for approved manufacturers of emergency ballasts. Lutron Hi-lume -lamp, 0VAC Dimming Ballast shown. Wire colors may vary depending on emergency ballast manufacturer. N Neutral (White) Dimmed Hot (Orange) Switched Hot (Black) Dimming Ballast Blue Blue Red Red Blue Blue/White Yellow Yellow/Black Red Emergency Ballast To Unswitched AC Black (77V) Orange (0V) White To Neutral DH SH H Yellow Lamp Lamp (Emergency) Battery Connector Indicator Light Load Terminals
8 rev gp-3a LOW-VOLTAGE CLASS (PELV) WIRING (ALL MODELS) Pull low-voltage type Class wiring for system communications. Must be daisy-chained! Must run separately from line (mains) voltage. Series 4000 GRAFIK Eye The Class (PELV) wiring link for system communications must be less than 000 feet (600m). Dimming Panel Control Unit Control Interface Wallstations Panel-to-Panel wiring Include one extra #8AWG (.0mm ). Used as a sense line for emergency (essential) lighting. Class (PELV) wiring link has: Two # AWG (.5mm ) conductors for control wiring. One shielded, twisted pair #8 AWG (.0mm ) for data link. GRAFIK 5000/6000 Systems Class (PELV) wiring links for system communications can be up to 4000 feet (00m): Use the -RPTR Interface and GRX-CBL-46L cable for links between 000 feet (600m) and 4000 feet (00m). Wire as shown for links 000 feet (600m) and less. Dimming Panel Processor Panel Control Unit Control Interface Wallstations Power Panel Link Panel-to-Panel wiring Include one extra #8AWG (.0mm ). Used as a sense line for emergency (essential) lighting. User Interface Link to PC Wallstation Links Each Class (PELV) has: Two # AWG (.5mm ) conductors for control wiring. One shielded, twisted pair #8 AWG (.0mm ) for data link. If you use Lutron cable, you can use smaller-gauge wires. If a Class (PELV) wiring link is less than 500 feet (50m), you can use GRX-CBL-346S: - Two #8AWG (.0mm ) for control wiring. - One twisted, shielded pair #AWG (.65mm ) for data link. - No sense line included - add your own #8AWG (.0mm ). If a Class (PELV) wiring link is 500 to 000 feet (50 to 600m), you can use GRX-CBL-46L: - Two #AWG (.5mm ) for control wiring. - One twisted, shielded pair #AWG (.65mm ) for data link. - One #8AWG (.0mm ) for sense line between Panels. Lutron has also approved smaller-gauge cable from Belden, Liberty, Alpha, and Signature. Ask for Lutron GRAFIK Eye Cable.
9 rev gp-4a CLASS (PELV) PANEL-TO-PANEL WIRING (ALL MODELS) To additional Power Panels 3,4 5 Control () # AWG (.5mm ) : Common : 4VFW Shield/ Data Link () shielded, twisted pair #8 AWG (.0mm ) 3: 4: () #8 AWG (.0mm ) 5: Sense Line Shield/ 3,4 To Lighting Controls or Processors 3 4 D D 5 Common +4VFW Sense Data A OK Power Data B OK Link A Link B 3 4 D 5 C D SELECT CIRCUIT Common Common +4VFW Sense Data A OK Power Data B OK Link A Link B 3 4 D 5 C D SELECT CIRCUIT Common Dimming Panel Dimming Panel Notes:. Emergency Power: The additional #8 AWG (.0mm ) wire is a sense line from terminal 5 of another Panel. This sense line allows an Emergency (Essential) Lighting Panel to sense when Normal (Non-Essential) power is lost. If more than one Emergency Lighting Panel needs to sense off a specific Normal Panel. You may have to run a dedicated wire between each pair of Normal (Non-Essential) and Emergency (Essential) panels.. Shield/: Connect shielding as shown. Do not connect to Ground (Earth) or Selector. Connect the bare drain wires and cut off the outside shield. CLASS (PELV) TERMINAL CONNECTIONS Each low-voltage Class (PELV) terminal can accept only two #8 AWG (.0mm ) wires. Two # AWG (.5mm ) conductors won't fit. Connect as shown. (4) # AWG (.5mm ) 3 4 D 5 Common 4VFW Data A OK Sense 3 4 D 5 SELECT CIRCUIT A Link Power Link B Comm C Data B OK D
10 rev gp-5a OPTIONS Consult Lutron for ordering information, model numbers, and ship times. Dimensions and wiring may change based on options chosen. OPTION DESCRIPTION APPLICATION Custom Main Lutron custom sizes Panels main breakers to meet job s Jobs with special load requirements. Breakers load requirements. Double Lug Sets Allows Panels to handle up to 5A feeds. You want a single feed but need multiple. Delta Power Allows Panels to accept Delta power feeds (phase-to-phase). Areas that have Delta Power. Available for 40V only. Limited to 0A, -pole circuits. Branch Protection Branch Breakers have higher AIC ratings than those on standard Panels. Panels can also have circuit breakers with special ratings such as: GFI (Ground Fault Interrupt) ELB (Earth Leakage Breaker) RCD (Residual Device). Lutron Allows Panels to operate fluorescent ballasts that meet Jobs with fluorescent ballasts that Ten Volt Module IEC 99 standards for 0-0V control including: require 0-0V, PWM, or DSI control. (TVM) Lutron s TVE ballasts 0-0V neon PWM fluorescent Tridonic DSI (Digital Serial Interface). The TVM can sink or source 5OmA (typically 5-50 ballasts) on each circuit. MRI Allows Panels to dim DC (direct current) lighting in MRI facilities or sound studios where Magnetic Resonance Imaging (MRI) facilities. standard lighting control equipment won t work because of RFI and EMI. Locking Covers Prevents accidental tripping of circuit breakers. Adds an Ideal for service corridors and public areas. additional.5 (57.mm) to the front of Panel. Available for GP8-GP4 only Link Allows a DMX5 theatrical console to operate When you need to control architectural Dimming Panels load circuits. lighting from a DMX5 theatrical console. Allows a GRAFIK Eye 4000 System to handle 8 zone When you need to mix architectural and (two links of 64 zones). theatrical lighting. Allows two GRAFIK Eye 4000 Systems to share When you have multiple systems but not the same Dimming Panel. enough space to hang Panels.
GP Dimming Panels 230 Volt (CE)
GAFIK Systems 30 Volt (CE) gp- 03.0.04 GP3/4 Mini Panels GP8-4 Standard-Size Panels provide power and dimming for up to 4 load circuits and control any light source, including full-conduction non-dim.
More informationLP Dimming Panels. GRAFIK Systems
GAFIK Systems lp-1 12.8.03 are ideal for projects with many small loads. Each panel provides power and dimming for up to 32 dimming legs. Features Work directly with incandescent, magnetic low voltage,
More informationGP Dimming Panels 230 Volt (CE)
30 Volt (CE).3.08 GP3/4 Mini Panels GP8-4 Standard-Size Panels provide power and dimming for up to 4 load circuits and control any light source, including full-conduction non-dim. Models available with:
More informationLCP128T Spec Grade Dimming System
LCP128T Spec Grade Dimming System 369-642a 1 06.04.12 System Overview LCP128T is a combination dimming and switching system that provides a complete lighting control solution. The system consists of panels
More information3-Wire Fluorescent Power Module
369355 Rev B 1 09.02.11 Description Provides capability for a zone on a GRAFIK EyeR control unit (or other product) to dim fluorescent lights that have Lutron Hi-lumeR and Eco-10R (Eco Series) line-voltage
More informationPhase-Adaptive Power Module with 3-Wire Fluorescent Input
369-358c 1 03.19.12 Description When connected to a 20 A circuit breaker, provides capacity on a 3-wire fluorescent dimmer for a full 16 A load of lighting. May be used to dim incandescent, halogen, electronic
More informationPhase-Adaptive Power Module
GAFIK Eye papm-1 3.12.08 Description Provides capability for a zone on a GAFIK Eye control unit (or other product) to dim a fully loaded circuit of lighting. May be used to control incandescent, electronic
More informationPhase-Adaptive Power Module
Phase-Adaptive Power Module Provides dimming control for 1 zone of a full 16 A lighting load. May be used to dim incandescent, halogen, electronic low-voltage, magnetic low-voltage, neon/cold cathode.
More informationDIN Power Module - Phase Adaptive
DI Power Module ow Capacity Phase Adaptive DI Power Module - Phase Adaptive 369849d 1 07.29.16 The Phase Adaptive Power Module family is a group of modular products for the control of lighting loads. This
More informationWired Vareo Local Lighting Controls
Wired Vareo Local Lighting Controls 8 Series Local Lighting Controls D48 Bus Architectural-Style L o c a l l i g h t i n g c o n t r o l s Wired Vareo local lighting controls function much like standard
More informationAdaptive Power Module
N QS Zones 0,5 N m 0-10 V- All Others 50 ma Z096 230 V~ 50/60 z 50 ma Up www.lutron.com +44.(0)20.7680.4481 1,2 N m 8 mm ains Only Outputs 230 V~ 10 AX each 1 2 3 4 Adaptive odule omeworks QS Phase Adaptive
More informationDIN Rail Power Module
800 W ax 500 W ax 500 W ax 500 W ax i Temp 230 V~ 50 / 60 z 10 A www.lutron.com +44.(0)20.7702.0657 DIN Rail odule omeworksr QS Phase Adaptive Fixture Controller DIN Rail odule The DIN Rail odule family
More informationAdaptive Power Module
N QS Zones 0,5 N m 0-10 V- All Others 50 ma Z096 230 V~ 50/60 z 50 ma Up www.lutron.com +44.(0)20.7680.4481 1,2 N m 8 mm ains Only Outputs 230 V~ 10 AX each 1 2 3 4 Adaptive odule omeworks QS Phase Adaptive
More informationWired Maestro Local Controls
Wired Maestro Local Controls 4 Series / 8 Series Local Controls H48 Bus Designer-Style L O C A L c o n t r o l s Wired Maestro local controls function much like standard dimmers and switches, but can be
More informationSwitching Power Module
369357d 1 06.20.13 Description Provides capability for a zone on a GRAFIK EyeR control unit (or other product) to switch a fully loaded circuit of lighting. May be used to switch incandescent, electronic
More informationEcoSystemR Multiple Control Input Ballasts
EcoR Multiple Control s 369454h 1 09.15.14 Digital electronic dimming ballasts maximize the benefits of a lighting management system. EcoR s offer 100% to 10% dimming; ideal for use where saving energy,
More informationEcoSystem Multiple Control Input Ballasts
Eco Multiple Control s Eco s 1 06.25.10 Digital electronic dimming ballasts maximize the benefi ts of a lighting management system. Eco s offer 100% to 10% dimming; ideal for use where saving energy, increasing
More informationEcoSystem Multiple Control Input Ballasts
Eco Five Control Digital Dimming s Eco Multiple Control s 369454l 1 09.02.16 Digital electronic dimming ballasts maximize the benefits of a lighting management system. Eco s offer 100% to 10% dimming;
More informationHi-lume LED Overview. LED Dimming Driver Hi-lume LED Architectural Dimming
Hi-lume LED Overview Hi-lume LED 1 12.11.9 Hi-lume LED is a high-performance, constant current driver that provides energy-efficient dimming for LED lighting. With industry-leading full-range % to 1% dimming,
More informationEcoSystem Dimming Power Module for 3-wire Lutron Dimming Ballasts. EcoSystem One-Line. EcoSystem C5-BMJ-16A. EcoSystem Dimming Module
Dimming Power Module for 3-wire Lutron Dimming Ballasts The Lutron dimming power module allows integration of Lutron 3-wire phase controlled dimming ballasts into Lutron bus supplies (Eco-10 and Hi-lume
More informationControls. CONTROLS AND ACCESSORIES PRODUCT FAMILY FEATURES DIMMERS DIMENSIONS SPECIFICATION SERIES STANDARD FEATURES
SPECIFICATION SUBMITTAL s The contractor s choice in rugged, linear slide dimmers. www.lutron.com/nova CONTROLS AND ACCESSORIES Slide-to-Off s Preset s Select light level with slider; slide down to off
More informationSAVE THESE INSTRUCTIONS
READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be
More informationUser Manual JS-ICON. 624 ARCH Dimmer Rack. JOHNSON SYSTEMS INC. Spring
User Manual JS-ICON 624 ARCH Dimmer Rack JOHNSON SYSTEMS INC. Spring 2007 2002161 Table of Contents JS-ICON 624 DMX JS-ICON 624 CC 6-2.4kW Dimming Strip JS-ICON 624 ND 6-2.4kW Relay Strip Introduction...3
More informationEcosystem 5 Percent 3-Wire and Ecosystem Digital Link Controlled T4 Compact, 1 Lamp, Ballast Factor Of 0.95, K-Can, Studded, 26/32W
3804 South Street 75964-7263, TX Nacogdoches Phone: 936-569-7941 Fax: 936-560-4685 EC3DT4MWKU1S 26/32W T4 1LMP Ba Lutron Catalog Number Manufacturer Description Weight per unit Product Category EC3DT4MWKU1S
More informationALD Dimmer Enclosures
ALD Enclosures FEATURES Attractive crinkle black finish. er Connection Power Supply Neutral Taps Modules (not included) Cooling Fans Dimming Electronics (not included) Available in 2 sizes: ALD6 (6 dimmer
More informationFluorescent (non-capacitive) Metal Halide 10A. 2 Any load circuit can be connected to any phase.
Installation Instructions Please Leave for Occupant HP-2, HP-4, & HP-6 Dimming Module 120/277VAC, 60Hz Description Dimming Module HP-2 2000W/VA 16A@120/277V 60Hz Listed Industrial Equipment 243C Dimming
More informationMaestro Wireless Dimmers and Switches
Maestro Wireless Dimmers and The Maestro Wireless solution incorporates Maestro Wireless load controls, wireless sensors, and wireless remote controls, which provide a system that delivers energy savings,
More information3-Wire Control, 220/240 Volt T-8 Linear, T-4 Quad Tube and T-5 Twin Tube Lamps
3-Wire Control, 220/240 Volt T-8 Linear, rev hi-220-240-1b 1.10.02 2.38 w (60mm) x 1.50 h (38mm) x 9.50 l (241mm) HOT DIMMED HOT NEUTRAL Hi-lume Power Control Dimming Ballast Lamps DESCRIPTION Continuous,
More informationGRX-TVI Ten Volt Interface
Lutron Power Interfaces Ten Volt Interface 369247e 1 07.07.16 Features 100-277 V~ forward, reverse, and center phase control input capability Provides control and switching capabilities to switch and dim
More informationGRX-TVI Ten Volt Interface
Lutron Power Interfaces Ten Volt Interface 36947d 07.07.4 Features 00-77 V~ forward, reverse, and center phase control input capability Provides control and switching capabilities to switch and dim current
More informationInstallation & User Instructions
Installation & User Instructions 16/25A Digital Dimmer (416/425) INTRODUCTION The 416 and 425 are Digital Dimmers capable of dimming a single channel with total loads of up to 16A and 25A respectively.
More informationGRX-TVI Ten Volt Interface
Lutron Power Interfaces Ten Volt Interface 369247c 1 09.17.13 Features 100-277 V~ forward, reverse, and center phase control input capability Provides 0-10 V- control and switching capabilities to switch
More informationA.C.E.S. Series ACES 3 & 6 MODULE PANELS. System Manual. Touch-Plate Lighting Controls. ACES 3 & 6 Module System Manual
Touch-Plate Lighting Controls ACES 3 & 6 Module System Manual A.C.E.S. Series ACES 3 & 6 MODULE PANELS System Manual Touch-Plate Lighting Controls 1830 Wayne Trace Fort Wayne, IN 46803 Phone: 260-424-4323
More information3-Wire Control, 120, 277 Volt T5 Twin Tube Compact Lamps, T4 Quad Tube and T4 Triple Tube
3-Wire Control, 120, 277 Volt, T4 Quad Tube and T4 Triple Tube rev hi-compact-1a 3.7.01 2.38 w (60mm) x 1.50 h (38mm) x 9.50 l (241mm) T4 - One Lamp 3.00 w (76mm) x 1.00 h (25mm) x4.90 l (124mm) T4 - Two
More informationHomeWorksR QS Wired MaestroR Architectural Local Controls
HomeWorks QS Wired Maestro local controls function much like standard dimmers and switches, but can be controlled as part of a lighting control system. Local lighting controls are useful in locations where
More informationUser s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual
User s Manual ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual ii ACS550-CC Packaged Drive with Bypass ACS550 Drive Manuals GENERAL MANUALS ACS550-01/U1 Drives User's
More informationResidential Systems Control of LED Lighting (120V)
Residential Systems Control of LED Lighting (120V) 1.0 Overview Light Emitting Diode (LED) lighting is becoming more prevalent in the marketplace and is often being implemented in residences in place of
More informationUser s Manual. ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual
User s Manual ACS550-CC Packaged Drive with Bypass Supplement for ACS550-01/U1 Drives User s Manual ii ACS550-CC Packaged Drive with Bypass ACS550 Drive Manuals GENERAL MANUALS ACS550-01/U1 Drives User's
More informationPD-Series Ground Fault Circuit Protection
PD-Series Ground Fault Circuit Protection SmartGuard is an equipment ground fault protection device that functions as a standard high-quality Carling hydraulic/ magnetic circuit breaker, offering customized
More informationInstallation Instructions
ADFE-A Three-Wire Fluorescent Multi-way Architectural Dimmer SPECIFICATIONS Dimming slider On/Off switch Label slot Voltage...2VAC, Hz Maximum Load Rating... A Minimum Load Rating....33A Narrow Dimmer:
More informationSAVE THESE INSTRUCTIONS
READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION IMPORTANT SAFEGUARDS! When using electrical equipment, basic safety precautions should always be
More informationUser s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual
User s Manual ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual ii ACH550-CC/CD Packaged Drive with Classic Bypass ACH550 Drive Manuals GENERAL MANUALS ACH550-UH
More informationINSTALLATION. **Microprocessor Status LED:
INSTALLATION VANTAGECONTROLS.COM VANTAGE INSTALL GUIDES 1061 South 800 East Orem, Utah 84097 Telephone 801 229 2800 Fax 801 224 0355 Standard Dimmer Module MODEL: SDM12-EM Overview The SDM12 dimmer module
More informationMaestro Wireless Dimmers and Switches
Maestro Wireless Dimmers and Switches The Maestro Wireless solution incorporates Maestro Wireless load controls, wireless sensors, and wireless remote controls, which provide a system that delivers energy
More informationInstallation Instructions Please Read Before Installing. Overview. Important Notes. Designer-Style Maestro Remotes HD-RD, -RS 120/127 V ~, 50/60 Hz
Installation Instructions Please Read Before Installing Overview The HD-RD and the HD-RS Switch are for use with HomeWorks Maestro s and Switches. Up to nine HD-RD s may be used with a HomeWorks Wired
More informationSO-SVCN- - GRAFIK Systems Sivoia QEDTM Controller
N- - Sivoia QEDTM Controller N-WH-E01 Color and Finish Codes LEDs I-WH- (Insert version) Engraving so-svc-1 10.20.07 Description Provides programming and control of one group of Sivoia QEDTM Window Treatments.
More informationTVE Overview. Lighting Management Dimming. Fluorescent Dimming Ballasts
TVE Overview Eco-0TM TVETM 0% TVE () 02.9.04 The (Eco-0) TVE is a 0% fluorescent dimming ballast for applications using a 0-0V control. TVE ballasts are also designed to work seamlessly with 0-0V lighting
More informationUser s Manual. ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual
User s Manual ACH550-CC/CD Packaged Drive with Classic Bypass Supplement for ACH550-UH HVAC User s Manual ii ACH550-CC/CD Packaged Drive with Classic Bypass ACH550 Drive Manuals GENERAL MANUALS ACH550-UH
More informationAT30 SERIES BATTERY CHARGER
STANDARD FEATURES 5 YEAR WARRANTY 5 Year Product Warranty Universal main control board operates in any AT Series charger Alarm assembly with local LEDs and summary relay contact for AC Failure, DC Failure,
More informationAF09... AF30 3-pole Contactors up to 20 HP / 480 VAC
AF0... AF0 -pole Contactors up to 20 HP / 480 VAC Contactors and Overload Relays Overview...2 AF0... AF0 -pole Contactors Ordering Details...4 Main Technical Data...20 DC Circuit switching...2 Main Accessory
More informationUser Manual. Solar Charge Controller 3KW
User Manual Solar Charge Controller 3KW 1 CONTENTS 1 ABOUT THIS MANUAL... 3 1.1 Purpose... 3 1.2 Scope... 3 1.3 SAFETY INSTRUCTIONS... 3 2 INTRODUCTION... 4 2.1 Features... 4 2.2 Product Overview... 5
More informationHi-lume Overview. EcoSystem Hi-lume 1% Architectural Dimming
cosystem Hi-lume % rchitectural imming Hi-lume Overview 369-398c 06.04. Hi-lume architectural electronic dimming ballasts are designed to meet the most demanding lighting requirements. y providing industry
More informationPowerLogic High Density Metering System 4-Meter Enclosure Installation Guide
PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide 7002-0289-00 Instruction Bulletin HAZARD CATEGORIES AND SPECIAL SYMBOLS Read these instructions carefully and look at the equipment
More informationTECHNICAL DATA SHEET KVA UPS Systemss
Återförsäljare: Tre Röda AB TillingeHagby 7-745 94 ENKÖPING Tel: 08-560 200 22 e-post: info@treroda.nu http: www.treroda.nu When the INSIDE is important make the OUTSIDE Cannon TECHNICAL DATA SHEET 400-500-600-800
More informationTECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)
TECHNICAL DATA SHEET INFINITY 3300 10 15 20 kva 3Ph(in) 3Ph(out) GENERAL INFORMATION POWER - kva 10 15 20 UPS typology ON LINE Double conversion ACTIVE stand by-operation (Optional) Nominal output power
More informationSeries KTU7 UL489 Molded Case Circuit Breakers
Series KTU7 UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s KTU7 series of UL Molded Case Circuit Breakers are UL489 and CE listed
More informationSeries KTU7 UL489 Molded Case Circuit Breakers
Series UL489 Molded Case Circuit Breakers Versatile, convenient and space saving for a variety of applications Sprecher+Schuh s series of UL are UL489 and CE listed for global applications. The current
More informationCompact SE Overview. High-Performance Dimming. Ballast
Compact SE Overview CompactSE 01.10.10 For designs requiring the energy savings and aesthetic appeal of dimmed T4 compact fluorescent or T5 twin-tube lamps, Compact SE dimming ballasts are your solution.
More informationHomeWorks QS Designer RF Maestro Local Controls
HomeWorks QS RF Maestro local controls function much like standard dimmers and switches, but can be controlled as part of a lighting control system. Local lighting controls are useful in locations where
More information4000 Series Slider Control Units GRXSLD 4103/4104/4106/4108 CAUTION! Description. System Specifications. Installation Instructions Occupant Copy
Installation Instructions Occupant Copy 4000 Series Slider Control Units GRXSLD 4103/4104/4106/4108 CAUTION! The GRXSLD Control Units are designed for residential or commercial applications indoor use
More informationPB-Series. GFCI/ELCI & Panel Seal
PB-Series GFCI/ELCI & Panel Seal The PB-Series utilizes the hydraulic magnetic principle which provides precise operation and performance even when exposed to extremely hot and/or cold application environments.
More informationIndustry Compliance The cabinet and modules are Listed to applicable UL Standards and requirements by Underwriters Laboratories Inc.
Power Switching Introduction CRESTRON GREEN LIGHT power switching cabinets come pre-configured with GLXP modules already installed. The cabinets only require installation and wiring of feed and load circuits.
More informationApplication Description
-14 Type, Intelligent Technologies (IT.) Soft Starters February 2007 Contents Description Page Type, Intelligent Technologies (IT.) Soft Starters Product Description....... -14 Application Description....
More informationINTRODUCING THE NEW MINI INVERTERS BY READY-LITE
INTRODUCING THE NEW MINI INVERTERS BY READY-LITE RELIABILITY THROUGH TECHNOLOGY FOR ECONOMICAL, RELIABLE POWER IN AN EMERGENCY, DEPEND ON MINI INVERTERS LED technology in emergency lighting systems has
More informationJBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER
JBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER JBE LED Dimming Controller for 110V* & 220V/ 240V AC LED Systems Thank you for purchasing high quality
More informationTOPAZ 24 DIMMER RACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT A)
TOPAZ 24 DIMMER RACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT-29132-1A) Contractor: Please read these instructions before starting installation. After installation, please forward this guide to the
More informationRadioRA 2 Maestro Local Controls
RadioRA 2 Maestro local controls function much like standard dimmers and switches, but can be controlled as part of a lighting control system. Local lighting controls are useful in locations where single
More informationMTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation
MTE SERIES RLW World REACTORS USER MANUAL PART NO. INSTR 030 REL. 090529 2009 MTE Corporation IMPORTANT USER INFORMATION NOTICE MTE Series RLW Line/Load Reactors are components designed to improve the
More informationM T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation
M T E C o r p o r a t i o n MATRIX FILTER SERIES B 380-415 Volts, 50HZ USER MANUAL PART NO. INSTR - 015 REL. 060628 2006 MTE Corporation IMPORTANT USER INFORMATION NOTICE The MTE Corporation Matrix Filter
More informationCONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS
LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS I. SCOPE a. This specification describes the necessary requirements for the design, fabrication, and operation of automatically switched, low
More informationTOPAZ 12 WALL PACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT A)
TOPAZ 12 WALL PACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT-29499-1A) Contractor: Please read these instructions before starting installation. After installation, please forward this guide to the user
More informationD2LC Series. Circuit Breaker Panelboards for Harsh and Hazardous Environments
D2LC Series Circuit Breaker Panelboards for Harsh and Hazardous Environments IBUTI TR HA ON DIS KILLARK Z LO C Type 4X Gasket Stainless Steel Tri-Lead Cover Bolts Spare Sealed Wires Termination at Terminal
More informationPRODUCTS: POWER SUPPLY
PRODUCTS: POWER SUPPLY Impact Lighting Inc. All rights reserved. Impact Lighting Inc. Reserves the right to change specifications without notice. 138 POWER SUPPLY 15W AC-DC [12V/1.25A] UNIVERSAL POWER
More informationDocument: PRODSPEC-140 Revision: G DCN No Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger
Document: PRODSPEC-140 Revision: G DCN No. 106512 Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger 1. GENERAL DESCRIPTION 1.1 General Description Fully regulated, constant voltage,
More informationACC Series Power Conditioner OPERATION & INSTALLATION MANUAL
ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL PHASETEC digital power conditioners are designed to safely operate electrical equipment in the harshest power quality environments. With a wide
More informationUser Manual Solar Charge Controller 3KW
User Manual Solar Charge Controller 3KW Version: 1.3 CONTENTS 1 ABOUT THIS MANUAL... 1 1.1 Purpose... 1 1.2 Scope... 1 1.3 SAFETY INSTRUCTIONS... 1 2 INTRODUCTION... 2 2.1 Features... 2 2.2 Product Overview...
More informationFIELD CONNECTIONS FOR YK CHILLER (STYLE G) OPTIVIEW CONTROL CENTER WITH REMOTE MEDIUM VOLTAGE SSS
Supersedes: 160.75-PW2 (508) Form 160.75-PW2 (311) FIELD CONNECTIONS FOR YK CHILLER (STYLE G) OPTIVIEW CONTROL CENTER WITH REMOTE MEDIUM VOLTAGE SSS WIRING DIAGRAM CONTRACTOR ORDER NO. YORK CONTRACT NO.
More information50 Hz Mini/Micro Computer Regulator (MCR) Series Installation and Operation Manual
Operating & Service Instructions Sola Minicomputer Regulators UL White Card Listed Power Supply Classification CSA Certified Transformer Classification General Description and Specifications The Sola Micro/Minicomputer
More informationM T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation
M T E C o r p o r a t i o n MATRIX FILTER SERIES B 380-415 Volts, 50HZ USER MANUAL PART NO. INSTR - 015 REL. 040709 2003 MTE Corporation IMPORTANT USER INFORMATION NOTICE The MTE Corporation Matrix Filter
More informationAF09... AF30 3-pole Contactors up to 25 HP / 600 VAC
AF09... AF0 -pole Contactors up to 25 HP / 600 VAC Contactors and Overload Relays Overview.../0 AF09... AF0 -pole Contactors.../2 Main Technical Data.../8 Main Accessory Fitting Details.../2 Main Accessory.../24
More informationFLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER
FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER INSTALLATION AND MAINTENANCE INSTRUCTIONS Risk of electric shock: Motor terminals may still be live if the impeller is rotating, even when
More informationIlluminator Series CR NEMA 3R
Illuminator Series CR NEMA 3R GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION For 3.0, 4.0, 5.0, 6.5, 8.0kVA / kw Series CR - Single Phase Uninterruptible Power System This description contains all the
More informationElegance Electrician s Installation Guide
Elegance Electrician s Installation Guide CentraLite Systems, Inc. 6420 Wall St. Mobile, AL 36695 Phone: 877-466-5483 Fax: 251-607-9119 2003-2005 CentraLite Systems, Inc. Revised 10/20/2005 ELECTRICIAN
More informationSTOREDGE TM. SolarEdge Single Phase StorEdge TM Solutions for North America SolarEdge StorEdge Solutions Benefits:
SolarEdge Single Phase StorEdge TM Solutions for North America 12-25 STOREDGE TM SolarEdge StorEdge Solutions Benefits: More Energy - DC-coupled architecture stores PV power directly to the battery without
More informationDemand Switch NEFA20 Plus. Installation Guide. Please read this entire guide before beginning the installation!
Demand Switch NEFA20 Plus Installation Guide Please read this entire guide before beginning the installation! Supplied Parts Protective Covers DIN Mounting Rail NEFA20 Plus Mounting Rail Spacer Warning
More informationREFERENCE MANUAL FORM: MX-TRM-E REL REV MTE
Matrix APAX 380V-415V 50Hz TECHNICAL REFERENCE MANUAL FORM: MX-TRM-E REL. September 2014 REV. 002 2014 MTE Corporation WARNING High Voltage! Only a qualified electrician can carry out the electrical installation
More informationDycon D2430 EN54-4 Fire Alarm Power Supply Series
Dycon D2430 EN54-4 Fire Alarm Power Supply Series Technical Description Installation and Operating Manual Construction Product Regulation 0359-CPR-00434 Page 1 of 14 Contents 1. General... 3 1.1 Product
More informationRental Power QSB7 series engine
Specification sheet Rental Power QSB7 series engine 150 kva 200 kva 50 Hz 135 kw 180 kw 60 Hz Description This Cummins commercial generator set is a fully integrated power generation system, providing
More informationOTEC Transfer switch open transition
Specification sheet OTEC Transfer switch open transition 40 1200 amp Description OTEC transfer switches are designed for operation and switching of electrical loads between primary power and Standby generator
More informationWiring Diagram Index. Find product, model #, and wiring diagram # Then find wiring diagrams on pgs
Wiring Diagram Index Find product, model #, and wiring diagram # Then find wiring diagrams on pgs.06-7 Architectural Diagram # Accessories NTR-5-6 NTR-5-GFCI- 7 NTR-5-IG-OR- 6 NTR-0-6 NTR-0-GFCI- 7 NTR-0-IG-OR-
More informationAurora Single Phase Emergency Lighting Inverters
Aurora Single Phase Emergency Lighting Inverters True Sine Wave On-Line Single Phase Emergency Lighting Inverters AURORA Series Emergency Lighting AC Inverters are among the most reliable systems available
More informationLP-2500/2600. Installation and Setup Guide. Lighting Control Panels. Revision 3.1 July 1999
/2600 Lighting Control Panels Installation and Setup Guide Revision 3. July 999 Phone:770-429-3043 http://www.triateklighting.com sales@triateklighting.com Installation Guide /2600 Lighting Panels Table
More informationIGLOO IGLOO EASY INSTRUCTION MANUAL
ENGLISH EASY C695 C698 INSTRUCTION MANUAL Congratulations on choosing a Clay Paky product! We thank you for your custom. Please note that this product, as all the others in the rich Clay Paky range, has
More informationEmergency lighting units PC COMBO
T5 PC, 220 240 V 50/60 Hz Linear fluorescent lamps Product description Combination of electronic ballast and emergency lighting unit For T5 fluorescent lamps Low-profile casing (21 x 30 mm cross-section)
More informationRELIABILITY THROUGH TECHNOLOGY
INTRODUCING THE NEW MINI INVERTERS BY LUMACELL RELIABILITY THROUGH TECHNOLOGY MAXIMIZE EFFICIENCY AND RELIABILITY WITH MINI INVERTER EMERGENCY POWER As LED technology increases the efficacy of emergency
More informationAdvantage-D. Operating Instructions and Maintenance Manual. Central Vacuum Systems (Expandable/Modular Models) (Ver.
Advantage-D Series 3 Central Vacuum Systems (Expandable/Modular Models) (Ver. 8/05) Operating Instructions and Maintenance Manual DESCRIPTION The Becker Advantage-D and Advantage-L central vacuum systems
More informationRadioRA 2 Maestro Local Controls
RadioRA Maestro local controls function much like standard dimmers and switches, but can be controlled as part of a lighting control system. Local lighting controls are useful in locations where single
More informationP-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant
P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant Applications Protection and control of electrical equipment and circuits
More informationVive Maestro Wireless Dimmers and Switches
Vive Maestro Wireless Dimmers and Switches The Maestro Wireless solution incorporates Maestro Wireless load controls, wireless sensors, and wireless remote controls, which provide a system that delivers
More informationAIS 5000 UPS kva 480 V. Installation Manual
AIS 5000 UPS 10-100 kva 480 V Installation Manual IMPORTANT! THIS DOCUMENT CONTAINS IMPORTANT SAFETY INSTRUCTIONS - PLEASE SAVE THESE INSTRUCTIONS! Contents Safety...1 IMPORTANT SAFETY INSTRUCTIONS - SAVE
More information