Development of Advanced HIII Abaqus dummies

Similar documents
New Side Impact Dummy Developments

Methodologies and Examples for Efficient Short and Long Duration Integrated Occupant-Vehicle Crash Simulation

THUMS User Community

Pre impact Braking Influence on the Standard Seat belted and Motorized Seat belted Occupants in Frontal Collisions based on Anthropometric Test Dummy

Overview of LSTC s LS-DYNA Anthropomorphic Models

Abaqus Technology Brief. Prediction of B-Pillar Failure in Automobile Bodies

Wheelchair Transportation Principles I: Biomechanics of Injury

THOR Specification and Certification Version 1.0 November 2018 TB 026

An Evaluation of Active Knee Bolsters

Full Width Test ECE-R 94 Evaluation of test data Proposal for injury criteria Way forward

Virtual human body model for fast safety assessment

Abaqus Technology Brief. Abaqus BioRID-II Crash Dummy Model

Simulation of Structural Latches in an Automotive Seat System Using LS-DYNA

STUDY ON CAR-TO-CAR FRONTAL OFFSET IMPACT WITH VEHICLE COMPATIBILITY

ARE SMALL FEMALES MORE VULNERABLE TO LOWER NECK INJURIES WHEN SEATED SUFFICIENTLY AWAY FROM THE STEERING WHEEL IN A FRONTAL CRASH?

THOR Mod Kit Update May Human Injury and Applied Biomechanics Research Divisions

Injury Risk and Seating Position for Fifth-Percentile Female Drivers Crash Tests with 1990 and 1992 Lincoln Town Cars. Michael R. Powell David S.

The THUMS User Community Harmonisation of THUMS in Different Crash Codes

Service Bulletin A

Potential Effects of Deceleration Pulse Variations on Injury Measures Computed in Aircraft Seat HIC Analysis Testing

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Humanetics is now shipping all ATDs for use in the U.S. NCAP at SBL-A and also offers upgrade kits for previously delivered dummies.

CRABI 12-Month Old Infant Dummy

Humanetics Innovative Solutions, Inc. Hybrid-III 95th Large Male Dummy H. Brand Harmonized Parts Catalog

WorldSID 50 th Update

Using the Abaqus BioRID-II Dummy to support the development of a Front Seat Structure during rear low speed crashes - Whiplash

Development of a Finite Element Model of a Motorcycle

FINITE ELEMENT METHOD IN CAR COMPATIBILITY PHENOMENA

Study on the Influence of Seat Adjustment on Occupant Head Injury Based on MADYMO

EFFECTIVENESS OF COUNTERMEASURES IN RESPONSE TO FMVSS 201 UPPER INTERIOR HEAD IMPACT PROTECTION

Australian Pole Side Impact Research 2010

JARI Research Activities for Traffic Safety

SLED TEST PROCEDURE FOR ASSESSING KNEE IMPACT AREAS

REPORT NUMBER: 214P-MGA SAFETY COMPLIANCE TESTING FOR FMVSS 214 DYNAMIC SIDE IMPACT PROTECTION RIGID POLE

ABSTRACT INTRODUCTION

Hybrid III 95th Large Male Full Assembly

ISO INTERNATIONAL STANDARD

REPORT NUMBER: 214P-MGA SAFETY COMPLIANCE TESTING FOR FMVSS 214 DYNAMIC SIDE IMPACT PROTECTION RIGID POLE

Accelerating the Development of Expandable Liner Hanger Systems using Abaqus

Crash test facility simulates frontal, rear-end and side collision with acceleration pulses of up to 65 g and 85 km/h (53 mph)

REPORT NUMBER: 214P-MGA SAFETY COMPLIANCE TESTING FOR FMVSS 214 DYNAMIC SIDE IMPACT PROTECTION RIGID POLE

SURFACE VEHICLE RECOMMENDED PRACTICE

Development and Validation of a Finite Element Model of an Energy-absorbing Guardrail End Terminal

Real World Accident Reconstruction with the Total Human Model for Safety (THUMS) in Pam-Crash

Post Crash Fire and Blunt Force Fatal Injuries in U.S. Registered, Type Certificated Rotorcraft

Frontalaufprall im Verbraucherschutz Frontal Impact In Consumer Test Programms

Research on Chest Injury Criteria

Simulation and Validation of FMVSS 207/210 Using LS-DYNA

Crash Simulation in Pedestrian Protection

Crashworthiness Simulation of Automobiles with ABAQUS/Explicit

Technical Product Sheet

SIMULATION OF A BACKREST MOMENT TEST FOR AN AUTOMOTIVE FRONT SEAT USING NONLINEAR CONTACT FINITE ELEMENT ANALYSIS

EMBARGOED NEWS RELEASE

Side Impact Protection. Technical perfection, automotive passion.

CAE Analysis of Passenger Airbag Bursting through Instrumental Panel Based on Corpuscular Particle Method

Road vehicles Design and performance specifications for the WorldSID 50th percentile male side impact dummy Part 2: Mechanical subsystems

Full Vehicle Durability Prediction Using Co-simulation Between Implicit & Explicit Finite Element Solvers

Application and CAE Simulation of Over Molded Short and Continuous Fiber Thermoplastic Composites: Part II

Migration of Crash Simulation Software at BMW

EUROPEAN NEW CAR ASSESSMENT PROGRAMME (Euro NCAP) ASSESSMENT PROTOCOL ADULT OCCUPANT PROTECTION

Lateral Protection Device

Simulation of proposed FMVSS 202 using LS-DYNA Implicit

Using ABAQUS in tire development process

Rear Impact Dummies. Z. Jerry Wang, PhD, Chief Engineer Eric Jacuzzi, Project Engineer

White Paper. Compartmentalization and the Motorcoach

Brand Harmonized Parts Catalog. Humanetics Innovative Solutions, Inc. BioRID II Rear Impact Male Dummy ARA-001-H

Effectiveness of ECP Brakes in Reducing the Risks Associated with HHFT Trains

Simulation of Occupant Posture Changes due to Evasive Manoeuvres and Injury Predictions in Vehicle Frontal and Side Collisions.

Side Impact and Ease of Use Comparison between ISOFIX and LATCH. CLEPA Presentation to GRSP, Informal Document GRSP Geneva, May 2004

Study concerning the loads over driver's chests in car crashes with cars of the same or different generation

EUROPEAN NEW CAR ASSESSMENT PROGRAMME (Euro NCAP)

THE INFLUENCE OF THE SAFETY BELT ON THE DECISIVE INJURY ASSESSMENT VALUES IN THE NEW US-NCAP

VIBRATIONAL ANALYSIS OF A MULTIBODY VIRTUAL DUMMY FOR CAR AND MOTORCYCLE USERS

Humanetics Innovative Solutions, Inc. EuroSID-2re Male Side Impact Dummy H. Brand Harmonized Parts Catalog

HEAD AND NECK INJURY POTENTIAL IN INVERTED IMPACT TESTS

FULL FRONTAL COLLISION SAFETY PERFORMANCE TEST PROCEDURE

Development of a Simplified Finite Element Approach for Investigation of Heavy Truck Occupant Protection in Frontal Impacts and Rollover Scenarios

Folksam bicycle helmets for children test report 2017

Crashworthiness Analysis with Abaqus

Abaqus Technology Brief. Automobile Roof Crush Analysis with Abaqus

REDUCING RIB DEFLECTION IN THE IIHS TEST BY PRELOADING THE PELVIS INDEPENDENT OF INTRUSION

Multibody Dynamics Simulations with Abaqus from SIMULIA

This paper details the development of the latest potential updates to the FMVSS No. 213 seat assembly 4 including the assembly s geometry,

Technical Note on the EuroSID-2 with Rib Extensions (ES-2re)

A Thesis by. Amirmasoud Moghaddami. Bachelor of Science, University of Kansas, 2015

Non-Linear Implicit Analysis of Roll over Protective Structure OSHA STANDARD (PART )

Skid against Curb simulation using Abaqus/Explicit

Automotive Seat Modeling and Simulation for Occupant Safety using Dynamic Sled Testing

Safer Vehicle Design. TRIPP IIT Delhi

Development and Component Validation of a Generic Vehicle Front Buck for Pedestrian Impact Evaluation

Development of a 2015 Mid-Size Sedan Vehicle Model

Benchmark Study on the AIRBAG_PARTICLE Method for Out-Of-Position Applications

CLIENT PROJECT REPORT

INFLUENCE OF BUMPER DESIGN TO LOWER LEG IMPACT RESPONSE

Vehicle Seat Bottom Cushion Clip Force Study for FMVSS No. 207 Requirements

Finite Element Modeling and Analysis of Crash Safe Composite Lighting Columns, Contact-Impact Problem

POLICY POSITION ON THE PEDESTRIAN PROTECTION REGULATION

ADVANCED RESTRAINT SY S STEM (ARS) Y Stephen Summers St NHTSA Ve NHTSA V hi hhicle S Saf t e y t R Resear R h c 1

FMVSS208 Simulation using Finite Element Methods

54 rd Meeting Informal Group on Child Restraint Systems Booster Seat Width Development. 27 th October2015

Transcription:

Visit the SIMULIA Resource Center for more customer examples. Development of Advanced HIII Abaqus dummies W. Li, J. Rasico, F. Zhu, M. Li, R. Kant, B. Aljundi First Technology Safety System Inc. Abstract: Hybrid III dummies are among the most frequently used dummies in both industry and academia for vehicle crash safety. Abaqus is one of most widely applied finite element codes in the world. To meet the needs of crash safety analysis and to exploit the potential of the Abaqus/Explicit code, a family of HIII dummies, including HII 50th male, 5th female and 95th male dummies, were developed at FTSS in collaboration with Simulia and BMW. This paper describes in detail the development of the HIII dummies with specific reference to the HIII 50th dummy. Firstly correct material models based on material test data are verified. Secondly variety of FTSS standard (certification-based) and non-standard finite element validation tests at component level, i.e. head drop, neck pendulum, lumbar spine, knee slider, knee impact and single rib tests, and at full dummy level, such as thorax pendulum, sled seatbelt and sled airbag tests, were accomplished. In addition, a suite of extra test, developed by the Partnership for Dummy Technology and Biomechanics (PDB), was integrated into the dummy development to enhance the fidelity and robustness of the dummy performances. Those tests include head impact (forehead and cheek), thorax impacts, tibia tests and foot and shoe tests. Based on these series of stringent validation tests, a family of HIII dummies have been successfully developed, which greatly facilitates virtual vehicle development and design process of the occupant safety in the automotive industry. Keywords: Dummy, Anthropomorphic Test Devices (ATD), Occupant protection, vehicle crash safety, Finite element Analysis 1. Introduction Since 2001, fatalities due to traffic accidents have been identified as the leading cause of death for people age 2 through 34 years old in the United States [R. Subramanian, 2003, 2005, 2006, and 2007]. Among all traffic fatalities, nearly 40% resulted from front impact accidents. The front impact therefore becomes one of the key crash safety areas targeted by both automobile manufacturers (OEMs) and academic researchers. Front impact dummies have been playing very important roles in front impact analysis for over two decades. Advances in processing power and explicit solver code capability in the last decade has created the possibility for detailed finite element dummy models to deliver timely high quality injury predictions for safety engineers, expanding what had previously been the realm of the fast running multi-body approach. In the past, safety-related relied heavily on a multi-body approximation of dummy mechanics and injury prediction. With the progress in biomechanics and the onset of much more stringent front impact safety regulations, the demands for better performance predictions in front impact safety analysis/development are constantly increasing. Finite element (FE) dummies like the Abaqus HIII series are the right tools to meet these demands. Advances in computer technologies make the 2008 Abaqus Users Conference 1 Visit the SIMULIA Resource Center for more customer examples.

application of the FE dummies affordable in front impact simulations, in terms of financial cost and efficiency. Dyna 3D, Pamcrash and Radioss have been used by most OEMs and suppliers worldwide in their crash safety development and analysis. In recent years, as one of most widely applied FE codes, Abaqus/Explicit has gained application in the crash safety area. First Technology Safety System has developed SID-IIs, ES2, ES2_RE FE Abaqus dummies and HIII 5th, 50th and 95th Abaqus ballast dummies in last few years. To meet the needs of the front crash safety analysis and to exploit the potential of the Abaqus/Explicit code, a family of HIII dummies, including HII 50th male, 5th female and 95th male Abaqus dummies, have been developed at FTSS in collaboration with Simulia and BMW. The FE HIII Abaqus dummies developed by FTSS are shown in Figure 1. Figure 1 Hybrid III 5th, 50th, 95th FE Abaqus dummy models The procedure for developing an FE dummy consists of a few key steps. To ensure the dummy performs well in terms of bio-fidelity and robustness, the first step is to obtain correct dummy geometry data so that the FE dummies will resemble in their physical counterparts. FTSS dummy geometries were obtained from the engineering drawings for the machined parts and from 3D scans for some other parts with complicated geometries and for deformable vinyl and foam parts. A series stringent FE validation tests at different level have then to be conducted, from material level, component level to finally full dummy level. 2. Tests at Material Level Developing accurate material models is a fundamental requirement for achieving good dummy behavior. Key drivers of the dummy performance include flesh components, i.e. hyperelastic polyurethane and elastomer foam fleshes, vinyl skins and rubber neck and lumbar spine. A wide range of testing applications is used in developing material models for Abaqus dummy models. The type of material and known behavior characteristics help in deciding the appropriate material testing. For example, foams with rate sensitivity may utilize multiple compression load cases at 2 2008 Abaqus Users Conference

varied speeds to capture this behavior. In such a test, as illustrated in Figure 2, the drop head acceleration is used as a performance measure. Marlow model is used in Abaqus for modeling the vinyl skins in the dummy development. The Marlow model is a firstinvariant hyperelastic material model and its main strength is in that with a dependence on the first-invariant, it does not need curvefitting procedures and can exactly reproduce the test data and performs quite well in other modes of deformation. [Abaqus v6.7, 2007]. Figure 2 Ensolite foam 3-speed test model Figure 3a shows the calibration of the Marlow model to the corresponding physical sample test. All foam materials in the dummies are modeled with the Abaqus rate sensitive foam material model [Abaqus v6.7, 2007]. Figure 3b, c and d illustrate the modeling results of the foam with the model, which exhibit excellent correlations. Rate = 100 S -1 Rate = 100 S -1 Rate = 100 S -1 Test rate_10 Test rate_100 rate_10 rate_100 Rate = 10 S -1 Test rat e_10 Test rate_100 rate_10 rate_100 Rate = 10 S -1 Test rate_10 Test rate_100 rate_10 rate_100 Rate = 10 S -1 Rate = 100 S -1 Test rate_10 Test rate_100 rate_10 rate_100 Rate = 10 S -1 a. b. c. d. Figure 3 Material validations: a. vinyl, b. Pelvis foam, c. Jacket foam, d. Abdomen foam 3. Tests at Component Level FTSS Tests During the dummy development, a series validation tests at component level are performed. These include the following tests: head drop, knee impact, knee slider, single rib, lumbar spine pendulum, neck pendulum (extension & flexion), abdomen foam, single rib, thorax drop, hip joint rotation range of motion, knee impact and knee slider [SAE, 1998]. The following sections present test results for some of these tests. 3.1 Head Drop Test Head injury criteria (HIC) is one of the most important dummy numbers in all related safety regulations, which is an acceleration based parameter. To ensure that the dummy can capture 2008 Abaqus Users Conference 3

acceleration responses accurately, a head drop test is conducted at two different impact velocities, i.e. at two different drop heights, 376 mm and 505 mm. This test assesses the forehead response to frontal impact with hard surface. The plots in Figure 4 show excellent correlation between the and the tests. Test hi gh Test l ow high low head Rigid plate Figure 4. Head drop test results. 3.2 Knee Impact Test In the knee impact test, the knee assembly is fixed at the end of the femur bone and an impactor with a mass of 5.0 kg impacts the knee at a velocity of 2.1 m/s, as shown in Figure 5. The impact force defined as the product of the impactor mass and its acceleration, and is recorded. A fair good correlation is achieved as illustrated in Figure 5. Test Figure 5a. Knee impact results Figure 5b. model 3.3 Knee Slider Impact Test This test is to characterize the knee slider properties. To transfer impact energy into the knee slider assembly, a load distribution bracket is required. A test probe with a mass of 12.0 kg impacts the bracket at a velocity of 2.75 m/s. The knee slider displacement and the femur force are recorded and compared with those of the physical test. The comparison, depicted in Figure 6, appears very good. 4 2008 Abaqus Users Conference

Test Figure 6a. Knee slider test results Figure 6b. model 3.4 Single Rib Drop Test To facilitate the calibration of the rib damping material, a special drop impact test is designed as plotted in Figure 7. The drop head is released at two different heights to achieve two different impact velocities respectively. The rib deflection and impactor acceleration are recorded. The comparison of the model correlates with those of the physical test quite well. Test - hi gh - high Test - l ow - low Figure 7a. Single rib test results Figure 7b. model 3.5 Lumbar Spine Test As an important load path between the upper and lower torso of the dummy, the performance of the lumbar spine plays a determining role in whole dummy performances, especially in unstrained impact scenario. In this test, the lumbar spine assembly is attached at one end of a pendulum and the pendulum is pin-fixed at the other end. A rigid block is fixed at the other end of the spine. The pendulum is then released at a height, which enables the spine to arrive at a specific impact velocity when it hits the honeycomb stopper. Figure 8 displays the test results and the FE model. 2008 Abaqus Users Conference 5

striker Test Lumbar spine Figure 8a. Lumbar spine test results Figure 8b. and FE model 3.6 Neck Pendulum Tests In this test, the head-neck assembly is fixed at the end of a pendulum and the other end of the pendulum is pin-fixed so that the pendulum and the head-neck assembly can rotate around the pin point. During the test, the pendulum is released and fall freely from two different heights to obtain a high and a low impact velocity respectively for the extension test and for the flexion test. The neck moment and shear force, and the neck rotation are monitored. It can be seen that the performances of the neck are very similar to those of the physical tests, as shown in Figure 9 for the extension tests and Figure 10 for the flexion tests. Test high high Test low low Figure 9a. Neck pendulum extension test results Figure 9b. model 6 2008 Abaqus Users Conference

Test high high Test low low Figure 10a. Neck pendulum flexion test results Figure 10b. model 3.7 Thorax Drop Test The thorax is the most complicated component in the H350 dummy model. The thorax drop tests with a circular drop head simulate the performances of the assembled thorax box under variety of loadings. The mass of the circular drop head is constant and the drop height varies at 4 different levels. This induces a chest deflection of 20 mm, 30 mm, 40 mm and 60 mm respectively. While in the thorax drop tests with a square drop head, both mass and drop height of the drop head changes, which forces the thorax box deform at different deformation rates. Very good correlations are provided in Figure 11 and Figure 12. Test 7.0 m/ s 7.0 m/ s Test 4.7 m/ s 4.7 m/ s Test 3.7 m/s 3.7 m/ s Test 2.2 m/ s 2.2 m/ s Test 7.0 m/ s 7.0 m/ s Test 6.0 m/ s 6.0 m/ s Test 5.0 m/ s 5.0 m/ s Figure 11. Thorax drop test (circular head) Figure 12. Thorax drop test (square head) 4. PDB Tests The partnership for Dummy Technology and Biomechanics (PDB) is a Germany organization, consisting of 5 automobile manufacturers. To assess and optimize dummy performances for vehicle safety, special tests were designed for dummy validations. The PDB tests related to HIII 2008 Abaqus Users Conference 7

dummies are divided into four groups: head impact tests, neck impact tests, thorax impact tests and tibia, foot/shoe impact tests. 4.1 Head Impact Tests The PDB head impact test consists of two different tests. In both PDB head impact tests, the headneck assembly is fixed at lower end of the neck. The first one is called cheek impact where the impactor hits the cheek of the head-neck model and the second forehead impact where the impactor targets the forehead of the model. Figure 13 and Figure 14 show head acceleration correlation between the and the corresponding physical tests for both validation tests, at a satisfactory agreement level. Test 3 Test 3 Fig.13. Cheek impact test Figure 14. Forehead impact test 4.2 Neck Impact Tests There are two different PDB neck impact tests, namely 2D and 3D tests. In both tests, the head-neck assembly is fixed at the skull back plate. For the 2D test, two fork-like loading devices are attached to the lower end of the neck in orthogonal directions. For the 3D test, three such loading devices are attached to the neck, which are perpendicular to each other. During the tests, the neck is undergoing 2D loading for the 2D test, and 3D loading for the 3D test. The upper neck loadcell is monitored and the outputs of the loadcell are correlated to those of the physical tests. Figure 15 and Figure 16 present a fairly good correlation for the 2D and 3D tests respectively. Figure 15 2D neck impact test 8 2008 Abaqus Users Conference

Test 3 Figure 16a. 3D neck impact: results, Figure 16b. model 4.3 Thorax Impact Tests The PDB thorax impact tests, as shown in Figure 17, can be cataloged as two groups of tests. The first one has 5 tests, which simulate seatbelt loadings at different locations of the front thorax. The second one has two tests, which imitate steering wheel loadings on the front thorax of dummies in two different sitting positions. The tests are designed to validate chest deflection for the dummy simulation models. The loading for the thorax impact test is applied with a prescribed displacement at a specific velocity level. Figure 18 and Figure 19 shows the reasonably good correlation results for the sternum central tests with/without jackets respectively. Figure 17. Thorax impact test models Test 3 Test 3 Figure 18. Sternum central impact/ without jacket Figure 19. Sternum central impact/ with jacket 2008 Abaqus Users Conference 9

4.4 Tibia and Foot/Shoe Tests There are three tests for the tibia test where the impactor hits the tibia at 3 different positions with a prescribed displacement and five for the foot/shoe test where the impactor impacts the foot (with or without shoes) at different locations and from different directions, as shown in Figure 20a. The simulation results for the upper and lower tibia loadcells have been plotted in Figure 20b where the impactor strikes at the middle of the tibia. Figure 20a. Tibia, foot/shoe test models Figure 20b. IP2a impact test results 5. Tests at Full Dummy Level After all validation tests at component levels are completed, three full dummy tests need to be conducted: thorax pendulum test, sled seatbelt test and sled airbag test. 5.1 Thorax Pendulum Impact Test In this standard thorax pendulum test, a pendulum impactor with a mass of 23.4 kg strikes the dummy in the thorax at a velocity of 6.7 m/s, as shown in Figure 21a. Figure 21b demonstrates very good correlation of the chest deflection and impactor force against those of the physical test. Figure 21a. Thorax pendulum impact model Figure 21b. Thorax pendulum test results 10 2008 Abaqus Users Conference

5.2 Sled Seatbelt Test As shown in Figure 22a, in the sled seatbelt test, the dummy is sitting on a rigid seat, which in turn is fixed on the sled. The dummy is restrained by a shoulder belt and a lap belt. A sled velocity pulse is applied, which represents a 30 mph front impact. Figure 23b illustrates correlations of the head, chest, pelvis acceleration and chest deflection of the dummy to those of the physical test. A comparison of the belt forces with the test belt forces are provided in Figure 23c. In general, the correlations for this test are satisfactory. Figure 22a. Sled seatbelt model Figure 22b. Sled seatbelt test results Figure 22c. Sled seatbelt test results 5.3 Sled Airbag Test Similar to the sled seatbelt test, in the sled airbag test model, the dummy is sitting on a rigid seat, which in turn rests on the sled, but without seatbelt restraint. Instead there is an unfolded airbag in front of the dummy on the steering wheel, as shown in Figure 23a. The loading for this test is the same as that applied in the sled seatbelt test. Figure 23b shows a reasonably good comparison of the head, chest and pelvis accelerations and the chest deflection against those of the real test. 2008 Abaqus Users Conference 11

Figure 23a. Sled airbag test model Test Figure 23b. Sled airbag test results 6. Model Summary Thin parts are modeled with 3-node and/or 4-node shell elements S3(S3R), S4R and some thin parts are modeled with continuum shell elements, SC6R and SC8R, which are better in coping with bending situation with only one layer of the elements than the shell elements. All block parts are modeled with 3D solid elements, C3D4, C3D6 and C3D8R. For the above mentioned elements, only linear, reduced integration elements are available in Abaqus/Explicit. The cable parts are modeled with the truss elements, T3D2. All loadcells are modeled with connector elements of type CARTESIAN and CARDAN. The revolute joints are model with the connector element of type HINGE and the spherical joints are simulated with the connector element of type JOIN and CARDAN. All accelerometers are built with the connector elements of type ACCELEROMETER. There are total 64300 nodes and 58444 elements in H350 dummy model. Table 1 lists a mass comparison of different dummy parts between the dummy and the physical dummy for H350. The dummy instrumentation is tabled in Table 2. 12 2008 Abaqus Users Conference

Table.1 Mass comparison Table 2. Dummy instrumentation Mass, kg Assembly Location Instrumentation Connector Element Physical dummy Abaqus dummy Head Accelerometer (1) ACCELEROMETER Head assembly 4.54±0.05 4.522 Loadcell - upper (1) CARTESIAN, CARDAN Neck Neck assembly 1.54±0.05 1.366 Loadcell - lower (1) CARTESIAN, CARDAN Upper torso with jacket 17.19±0.36 16.65 Accelerometers (3) ACCELEROMETER Lower torso assembly 23.04±0.36 23.87 Thorax Loadcell (1) CARTESIAN, CARDAN Upper leg assembly, left 5.99±0.09 6.772 Rotational meter (1) CARDAN Upper leg assembly, right Lumbar spine Loadcell (1) CARTESIAN, CARDAN 5.99±0.09 6.772 Pelvis Accelerometers (3) ACCELEROMETER Low leg assembly, left 5.44±0.14 6.066 Loadcells - Left (2) CARTESIAN, CARDAN Low leg assembly, right 5.44±0.14 6.065 Upper legs Loadcells - Right (2) CARTESIAN, CARDAN Upper arm assembly, left 2.00±0.05 1.979 Loadcells - Left (2) CARTESIAN, CARDAN Upper arm assembly, right Lower legs 2.00±0.05 1.977 Loadcells - Right (2) CARTESIAN, CARDAN Lower arm/hand, left 2.27±0.09 2.365 Loadcells - Left (2) CARTESIAN, CARDAN Knee Lower arm/hand, right 2.27±0.09 2.365 Loadcells - Right (2) CARTESIAN, CARDAN Total dummy weight 77.70±1.18 77.65 Foot 2 Accelerometers ACCELEROMETER 7. Conclusions An Abaqus family of HIII dummies has been successfully developed following a rigorous development procedure. This procedure includes a series of stringent validation tests, ranging from material level, component level to full dummy level. Based on the validation results for the H350 dummy shown in this paper, the dummies are capable enough to be used in front impact analysis for the purpose of vehicle/occupant safety, though there is room for further improvement. All three HIII dummies have been successfully used in the automobile industry. 8. ACKNOWLEDGEMENT The authors feel grateful to BMW, Simulia and the PDB for their continuous help and corporations throughout the projects. 9. REFERENCES 1. Rajesh Subramanian, Motor Vehicle Traffic Crashes as a Leading Cause of Death in the United States, 2003/2004/2005, Research Note, NCSA, DOT HS 809 695, Dec. 2003, June, 2005, March, 206, March 2007. 2. Abaqus v6.7 Users Manuals; 3. SAE Engineering Aid 23, User s manual for the 50th Percentile Male Hybrid III Test Dummy, June, 1998. Notes: All curves in this paper are normalized. 2008 Abaqus Users Conference 13 Visit the SIMULIA Resource Center for more customer examples.