Not to be distributed outside of FM Approvals and its affiliates except by Customer

Similar documents
Not to be distributed outside of FM Approvals and its affiliates except by Customer APPROVAL REPORT. Model A-FS-CM-SP Skylight Skyco Skylights

Not to be distributed outside of FM Approvals and its affiliates except by Customer APPROVAL REPORT. Skylight. VELUX America LLC

DIVISION: OPENINGS SECTION: UNIT SKYLIGHTS REPORT HOLDER: VELUX AMERICA LLC POST OFFICE 5001 GREENWOOD, SOUTH CAROLINA 29648

Equivalency Evaluation to 2010 FBC

Product Evaluation Report

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued May 1, Legacy report on the 1997 Uniform Building Code

TEST REPORT. Report No.: G Rendered to: VELUX America LLC Greenwood, South Carolina

ESR ICC Evaluation Service, Inc. Issued December 1, 2006 This report is subject to re-examination in one year.

AAMA/WDMA/CSA 101/I.S.2/A TEST REPORT. Rendered to: MASTER WINDOW SYSTEMS, INC.

DASMA DASMA

AFG501 ALUMINUM FEMA 361 LOUVER LOUVER TYPE RECOMMENDED SPECIFICATION

GENERATOR SHELTER IMPACT TEST REPORT (.08 Material)

SINGLE SLIDING WINDOW 1000 SERIES 4-1/2" FRAME SINGLE SLIDER LIFT OUT

TEST REPORT. Report No.: G Rendered to: SKYCO SKYLIGHTS Costa Mesa, California

TEST REPORT. Rendered to: HOMELAND VINYL PRODUCTS, INC. For: PVC Guardrail System Utilizing New Nylon/PVC Rail Mounting Bracket

APIB Test Specification No. 10 Skylights SWISS HAIL IMPACT PROTECTION REGISTER HSR / 10-15de Version 1.04

SFI SPECIFICATION 15.4 EFFECTIVE: JULY 20, 2010 * PRODUCT: Top Fuel and Funny Car Drag Race Drive Beadlock Wheels

SFI SPECIFICATION 27.1 EFFECTIVE: OCTOBER 11, 2006 *

CONSTRUCTION CONSULTING LABORATORY, INTERNATIONAL

Equivalency Evaluation to 2010 FBC

CLASSIFICATION NOTES. Type Testing Procedure for. Crankcase Explosion Relief Valves

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: GLASSCRAFT DOOR COMPANY Houston, Texas

AGREEMENT. (Revision 2, including the amendments entered into force on 16 October 1995) Addendum 102: Regulation No. 103

A. This Section includes the following types of sectional overhead doors:

SFI SPECIFICATION 32.1 EFFECTIVE: MARCH 24, 2009 *

AlumaView AV200. A. Section Metal Fabrications: Miscellaneous for steel supports.

E/ECE/324/Rev.2/Add.112/Rev.3/Amend.6 E/ECE/TRANS/505/Rev.2/Add.112/Rev.3/Amend.6

SFI SPECIFICATION 1.3 EFFECTIVE: MAY 23, 2000 * PRODUCT: Nitro-Methane Drag Race Multiple Disc Clutch Assemblies

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: GLASSCRAFT DOOR COMPANY Houston, Texas

William R. Heiden III, P.E.

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: GLASSCRAFT DOOR COMPANY Houston, Texas

DIVISION: OPENINGS SECTION: UNIT SKYLIGHTS REPORT HOLDER: NATURAL LIGHT ENERGY SYSTEMS

UNITED STATES COAST GUARD OCEAN ENGINEERING DIVISION WASHINGTON, D.C. JANUARY 2011 SPECIFICATION FOR THE MANUFACTURE

REPORT NUMBER: MID-001 ORIGINAL ISSUE DATE: Sept 27, 2013 REVISED DATE: NA

continuous mounting flange intended for direct attachment to roofing substrate.

Modification Record of Product Specification

SFI SPECIFICATION 28.1 EFFECTIVE: AUGUST 25, 2017 *

IEA SHC Task 27: Accelerated Aging of IG units: North American Test Methods

AAMA/WDMA/CSA 101/I.S.2/A440-08

Approval Standard. for. Explosionproof Electrical Equipment General Requirements

E/ECE/324/Rev.1/Add.57/Rev.3 E/ECE/TRANS/505/Rev.1/Add.57/Rev.3

BS EN :2006. Windows and doors Product standard, performance characteristics. A Report To: Mila Hardware Ltd. Document Reference:

SAVING ENERGY SEAMLESSLY FULLY ENCAPSULATED SKYLIGHT

ALPHA 70K TMA (Truck Mounted Attenuator) GENERAL SPECIFICATIONS

SFI SPECIFICATION 1.1 EFFECTIVE: NOVEMBER 9, 2001 *

TÜV NEDERLAND P.O. Box AC Best - The Netherlands De Waal 21C PH Best - The Netherlands +31 (0) (0)

DETAIL SPECIFICATION SHEET

Doc:TED 11(794)W 1 September 2012 Draft Standard Automotive Vehicles - Windscreen Wiping System for 3 Wheeler Vehicles - Specification

Safe-Stop TMA (Truck Mounted Attenuator) GENERAL SPECIFICATIONS

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR PAVEMENT RIDE QUALITY (MEAN ROUGHNESS INDEX ACCEPTANCE CRITERIA)

Originally Issued: 09/26/2012 Revised: 09/29/2017 Valid Through: 09/30/2018

STATE OF NORTH CAROLINA D DEPARTMENT OF ADMINISTRATION MARCH 20, 1995 PURCHASE AND CONTRACT DIVISION 7125-LM-2C November 9, 1989

Code Compliance Research Report CCRR-0258

Reg Consolidated to Supplement 2 (Revision 3 Amendment 2)Replacement Brake Linings

Reference Number: SMS-4211-L1, Rev 0 Date: May 2, 2018

SFI SPECIFICATION 1.2 EFFECTIVE: FEBRUARY 9, 2006* PRODUCT: Multiple Disc Clutch Assemblies for Vehicles with Naturally Aspirated Engines

SFI SPECIFICATION 35.2 EFFECTIVE: DECEMBER 29, 2014 *

E/ECE/324/Rev.2/Add.123/Amend.1 E/ECE/TRANS/505/Rev.2/Add.123/Amend.1

Urban Wildfire Interface: Exterior Wall Wildfire Testing

PRODUCT EVALUATION REPORT

AIRTEK, INC. (dba CATCO) "THREE WAY PLUS OXIDATION CATALYTIC CONVERTER SERIES 44000"

GENERAL SPECIFICATION

SteelForm S-24C SECTIONAL OVERHEAD DOORS

SFI SPECIFICATION 4.2 EFFECTIVE: OCTOBER 26, 1994*

KEEP FOR FUTURE REFERENCE DC VACUUM BACK-UP SYSTEM READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT

SFI SPECIFICATION 28.3 EFFECTIVE: APRIL 21, 2014 *

E/ECE/324/Rev.2/Add.102/Rev.1 E/ECE/TRANS/505/Rev.2/Add.102/Rev.1

SFI SPECIFICATION 7.2 EFFECTIVE: DECEMBER 15, 2006 *

Hydrogen Station Equipment Performance Device (HyStEP Device) Specification

SFI SPECIFICATION 34.1 EFFECTIVE: January 13, 2017*

Submittal Requirements for Product Evaluation - Doors

SFI SPECIFICATION 35.1 EFFECTIVE: AUGUST 26, 2008 *

CREEK Technical Services, LLC

CERTIFICATE OF COMPLIANCE

AAMA/WDMA/CSA 101/I.S.2/A440-08

ThermaSeal TM220 SECTIONAL OVERHEAD DOORS

Report No: Test of: Reversible aluminium/timber window. Tested to: BS :2009 Performance of windows & doors Part 2: Operation & strength

SFI SPECIFICATION 39.2 EFFECTIVE: August 25, 2017 *

CRASH TEST REPORT FOR PERIMETER BARRIERS AND GATES TESTED TO SD-STD-02.01, REVISION A, MARCH Anti-Ram Bollards

CRASH TEST REPORT FOR PERIMETER BARRIERS AND GATES TESTED TO SD-STD-02.01, REVISION A, MARCH Anti-Ram Bollards

E/ECE/324/Rev.2/Add.108/Rev.1/Amend.3 E/ECE/TRANS/505/Rev.2/Add.108/Rev.1/Amend.3

4.28±0.05V 2.4±0.1V. W :29.0mm T :11.1mm

UNITED STATES DEPARTMENT OF AGRICULTURE FOREST SERVICE STANDARD FOR SPARK ARRESTERS FOR INTERNAL COMBUSTION ENGINES

Roof Hatches Smoke Vents /BAB BuyLine 0898

Purpose. Revised Service

CREEK Technical Services, LLC

SFI SPECIFICATION 15.2 EFFECTIVE: MAY 1, 2008 *

Apr11 Rev A

ECE/RCTE/CONF/4/Add.1/Rev.2

SFI SPECIFICATION 3.2A EFFECTIVE: APRIL 20, 2018 *

E/ECE/324/Add.5/Rev.6/Amend.2 E/ECE/TRANS/505/Add.5/Rev.6/Amend.2

Certificate of Compliance

LISTING REPORT/INSPECTION PROCEDURE

TM MANUFACTURERS

American National Standard

*Friedman Research Corporation, 1508-B Ferguson Lane, Austin, TX ** Center for Injury Research, Santa Barbara, CA, 93109

SECTION SECTIONAL OVERHEAD DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

Model Description Vac. Max rating Pedestal Only: 36 Utility Pedestal W/O Disconnect General Duty Series:

ROOF HATCHES. Over 45 years of proven performance in Standard & Custom Designed Hatches SINCE 1965 NOW WITH R-20 INSULATED ROOF HATCHES!

Transcription:

Not to be distributed outside of FM Approvals and its affiliates except by Customer APPROVAL REPORT APPROVAL OF TUFFLITE TRIARCH MODEL ALT-CM- 1-PC AND TUFFLITE TRIARCH MODEL ALT-CM-2-CPC SKYLIGHTS PER FM APPROVAL STANDARD 4431 SKYLIGHTS Prepared for: Bristol Fiberlite Industries Inc dba Bristolite Skylights 401 E Goetz Ave Santa Ana, CA 92707 United States Class: 4431 Date of Approval: 11/26/2012 Authorized by: Cynthia E. Frank, AVP, Group Manager, Materials FM Approvals 1151 Boston Providence Turnpike P.O. Box 9102 Norwood, MA 02062 1 of 7

APPROVAL OF TUFFLITE TRIARCH MODEL ALT-CM-1-PC AND TUFFLITE TRIARCH MODEL ALT-CM-2-CPC SKYLIGHTS PER FM APPROVAL STANDARD 4431 SKYLIGHTS from Bristol Fiberlite Industries Inc dba Bristolite Skylights 401 E Goetz Ave Santa Ana, CA 92707 United States I INTRODUCTION 1.1 Bristolite Skylights submitted their TUFFLITE TRIARCH Model ALT-CM-1-PC and Model ALT-CM-2-CPC skylights to determine if they meet the Approval requirements of the Standard listed below for skylights. Bristolite Skylights examined in this report are of an aluminum frame construction with polycarbonate and acrylic domed lenses. 1.2 This report may be reproduced only in its entirety and without modification. 1.3 Standard: Title Class Number Date Approval Standard for Skylights 4431 September, 2006 1.4 Examination included Spread of Flame Test for Skylights from an Exterior Ignition Source, Simulated Hail Resistance Test Using Freezer Ice Balls and UV Testing, Simulated Impact Tests for Skylights and Simulated Wind Uplift Resistance Test for Skylights. 1.5 As a fabricator of an Approved product, the Bristolite Skylights facility is audited on a regular basis to determine that sufficient quality controls are being used to assure continued production equivalent to that originally Approved. 1.6 Tests show that the Bristolite Skylights TUFFLITE TRIARCH Model ALT-CM-1-PC and Model ALT-CM-2-CPC skylights meet the Approval requirements of the Standard listed above for skylights. 1.7 Listings: The product will be listed in the Approval Guide, an online resource of FM Approvals. II DESCRIPTION Bristolite Skylights TUFFLITE TRIARCH Model ALT-CM-1-PC and Model ALT-CM-2-CPC skylights are available in sizes up to 4 ft (1.2 m) by 8 ft (2.4 m) and 5 ft (1.5 m) by 6 ft (1.8 m). The skylights are produced with a Type 6063-T6 aluminum frame that is secured to a 1.5 in. (38 mm) thick wood curb and are available in single dome (Model ALT-CM-1-PC) or double dome (Model ALT-CM-2-CPC) units. Model ALT-CM-1-PC skylights are fabricated with single domed lenses formed out of minimum 0.118 in. (3.0 mm) thick polycarbonate sheet material and Page 2 of 9

Model ALT-CM-2-CPC skylights are fabricated with an additional inner dome formed out of minimum 0.098 in. (2.5 mm) thick clear acrylic sheet material. III EXAMINATIONS AND TESTS 3.1 Samples were submitted for examination and testing as follows: 3.1.1 Tests conducted were as required by the Standard listed in paragraph 1.3 above. 3.1.2 Production of the Bristolite Skylights TUFFLITE Model ALT-CM-1-PC and Model ALT-CM- 2-CPC skylight samples were witnessed by a representative of FM Approvals on February 15, 2012 at the Bristolite Skylights production facility in Santa Ana, California, USA. All data is on file at FM Approvals under Project ID 3044352 along with other documents and correspondence applicable to this program. 3.2 Spread of Flame Tests from an Exterior Ignition Source 3.2.1 The fire tests from an exterior ignition source were conducted in accordance with a modified version of ASTM E108 Spread of Flame Tests, as documented in the Approval Standard referenced in section 1.3. Testing was completed using the FM Approvals ASTM E108 Spread of Flame Test Apparatus. 3.2.1.1 The wind velocity over the top of the standard panel was adjusted to 12 ± 0.5 mph (5.3 ± 0.2 m/s). 3.2.1.2 Flame exposure: The flame was adjusted to 1400 ± 50 F (760 ± 28 C) for Class A. The flame temperature was measured by a thermocouple located 1 in. (25.4 mm) above the surface of the standard panel and 1/2 in. (13 mm) toward the flame source from the lower edge of the standard panel. The flame was applied to each test panel for 10 minutes. 3.2.1.3 During and after the application of the flame, each panel was observed for the distance of maximum flame spread, flaming of melting particles and other damage. 3.2.2 Two test samples were prepared. The components and sequence of installation were as follows: Samples 1 and 2: Samples 3: Bristolite Skylights TUFFLITE Model 4896 ALT-CM-1-PC (single skin) skylight measuring 4 ft (1.2 m) by 8 ft (2.4 m) with 0.118 in. (3.0 mm) thick polycarbonate dome, secured to a metal test frame Bristolite Skylights TUFFLITE Model 4896 ALT-CM-2-CPC (double skin) skylight measuring 4 ft (1.2 m) by 8 ft (2.4 m) with 0.118 in. (3.0 mm) thick polycarbonate outer dome and 0.098 in. (2.5 mm) thick inner acrylic dome, secured to a metal test frame 3.2.3 The results of the Spread of Flame Tests from an Exterior Ignition Source were as follows: Sample No. Slope Maximum Flame Spread Rating 1 1 in 12 No Ignition Class A Page 3 of 9

2 1 in 12 No Ignition Class A 3 1 in 12 No Ignition Class A Melting and sagging of the samples was observed. The melted material was not glowing or flaming nor did it come in contact with the floor. The samples were permanently deformed during testing. 3.3 Simulated Hail Resistance Tests Using Freezer Ice Balls 3.3.1 Tests were conducted using the FM Approvals Freezer Ice Ball Simulated Hail Damage Test Apparatus to evaluate the ability of the skylight glazing materials to withstand a hailstorm without developing any through openings. 3.3.1.1 Two samples of the test material were submitted for testing. The first sample of the material was designated as Sample A and was conditioned at 40 F ±5 F (4 C ±3 C) for a period of not less than 48 hours immediately prior to the test. 3.3.1.2 The second sample of the material was designated as Sample B and was conditioned (weathered) for 1000 hours in the FM Approvals Ultraviolet Weatherometer prior to conditioning at 40 F ±5 F (4 C ±3 C) for a period of not less than 48 hours immediately prior to the test. 3.3.1.3 Each sample was tested within five (5) minutes of being removed from the 40 F ±5 F (4 C ±3 C) conditioning box. 3.3.2 For the severe hail damage tests, a 2.0 in. (51 mm) diameter frozen ice ball with a nominal weight of 0.1385 lbs (62.9 g), +10/-0% was projected at each test sample at a nominal speed of 76.1 mph, +10/-0% in order to impact the sample with a nominal kinetic energy of 26.8 ft-lbs (36.4 J), +10/-0%. This procedure was repeated 10 times within a 12 in. (305 mm) diameter location on each of the test samples. After each impact the sample was inspected for any through openings. 3.3.3 Two 13 in. x 13 in. (330 mm x 330 mm) samples were prepared. The results were as follows: Sample ID Sample Material Result A 0.118 in. (3.0 mm) thick Polycarbonate Dome Material Pass B 0.118 in. (3.0 mm) thick Polycarbonate Dome Material Pass 3.4 FM Approvals Simulated Impact Tests 3.4.1 Tests were conducted using the FM Approvals Simulated Impact Test Apparatus to evaluate the ability of the skylight to resist simulated impacts without damage. 3.4.1.1 A cylindrical canvas bag impactor with a diameter of 12 in. (305 mm) and filled with dry sand to a total assembly weight of 100 lbs (45.5 kg) ± 4 oz. (113.4 g) was dropped from a height of 4 ft (1.2 m) above the highest surface of the test panel. 3.4.1.2 The profile being considered for Approval was subjected to two (2) separate impacts from the impactor. The first impact was located within a 12 in. (305 mm) diameter circle located at the test specimen s center point. The second impact was located within 12 in. (305 mm) from the end support. Page 4 of 9

3.4.1.3 There must be no through openings through which a 4 in. (102 mm) diameter sphere can pass. The dome shall not become dislodged from the curb or drop out. 3.4.2 One sample, with the largest dome area for which Approval is sought, was prepared. Sample: Result: Bristolite Skylights TUFFLITE Model 4896 ALT-CM-1-PC measuring 4 ft (1.2 m) by 8 ft (2.4 m), with 0.118 in. (3.0 mm) thick single skin Polycarbonate dome. No damage to the sample was observed after either impact. 3.5 FM Approvals 5 by 9 ft (1.5 by 2.7 m) Simulated Wind Uplift Pressure Test 3.5.1 The test was conducted using the FM Approvals Uplift Pressure Test Apparatus to evaluate the ability of the skylight to resist a minimum simulated wind uplift pressure of 60 psf (2.9 kpa) without failure of the assembly. 3.5.1.1 The simulated wind uplift pressure test utilized a 5 ft. (1.5 m) long by 9 ft. (2.7 m) wide by 2 in. (51 mm) deep steel pressure vessel arranged to apply air pressure at pre-established standard rates to the underside of the test sample which formed the top of the pressure vessel. The vessel was pressurized with compressed air. 3.5.1.2 A net pressure of 30 psf (1.4 kpa) was applied to the test sample and maintained for 1 minute. The pressure was increased to 45 psf (2.2 kpa), then to 60 psf (2.9 kpa) and held for 1 minute at each increment. The pressure was increased in increments of 15 psf (0.7 kpa) every minute until failure occurred. 3.5.2 One 5 by 9 ft. (1.5 by 2.7 m) test sample was prepared. The components, sequence of installation and test result are as follows: Sample No: Result: Polyethylene sheet, 6 mil (0.006 in., 0.25 mm) thickness, loose laid over the FM Approvals Wind Uplift Frame. Bristolite Skylights TUFFLITE Model 4896 ALT-CM-1-PC measuring 4 ft (1.2 m) by 8 ft (2.4 m) with aluminum frame secured to minimum 1.5 in. (38 mm) thick wood curb framing with #10 self tapping stainless steel screws secured through all four sides of the aluminum frame and spaced maximum 6 in. o.c. (152 mm). The sample withstood a pressure of 150 psf (7.2 kpa) for 1 minute as required by the test standard and meets the criteria for a rating of 150 psf (7.2 kpa). The sample failed during the incremental pressure increase to 165 psf (7.9 kpa) due to fastener withdrawal from the aluminum frame material. IV MARKING 4.1 The manufacturer shall mark each skylight unit with the manufacturer's name and product trade name. In addition, the skylight unit must be marked with the Approval Mark of FM Approvals. 4.2 Markings denoting Approval by FM Approvals shall by applied by the manufacturer only within Page 5 of 9

and on the premises of manufacturing locations that are under the FM Approvals Facilities and Procedures Audit program. 4.3 The manufacturer agrees that use of the FM Approvals name or Approval Mark is subject to the conditions and limitations of the Approval by FM Approvals. Such conditions and limitations must be included in all references to Approval by FM Approvals. V FACILITIES AND PROCEDURES AUDITS The Bristolite Skylights manufacturing location in Santa Ana, California is subject to periodic audit inspections to determine that the quality and uniformity of the materials have been maintained and will provide the same level of performance as originally FM Approved. The facilities and quality control procedures in place have been found to be satisfactory to manufacture product identical to that examined and tested as described in this report. VI MANUFACTURER'S RESPONSIBILITIES 6.1 To assure compliance with his procedures in the field, the manufacturer shall supply to the roofer such necessary instruction or assistance required to produce the desired performance achieved in the tests. 6.2 The manufacturer shall notify FM Approvals of any planned change in the FM Approved product, prior to general sale or distribution, using Form 797, FM Approved Product Revision Report. VII DOCUMENTATION The following document describes the product and is used for conducting follow-up audits. Document Issue Description Bristolite Skylights TUFFLITE TRIARCH Model ALT-CM-1-PC and Model ALT-CM-2-CPC Skylights November, 2012 Facilities and Procedures Audit Manual VIII CONCLUSIONS 8.1 The test results from this program indicate that Bristolite Skylights TUFFLITE TRIARCH Model ALT-CM-1-PC and Model ALT-CM-2-CPC skylights meet the requirements of FM Approvals Standard 4431, Approval Standard for Skylight as indicated below. 8.1.2 Bristolite Skylights TUFFLITE TRIARCH Model ALT-CM-1-PC and Model ALT-CM-2-CPC skylights are provided in sizes 4 ft (1.2 m) by 8 ft (2.4 m) and 5 ft (1.5 m) by 6 ft (1.8 m). Model ALT-CM-1-PC skylights are fabricated with single domed lenses formed out of minimum 0.118 in. (3.0 mm) thick polycarbonate sheet material. Model ALT-CM-2-CPC skylights are fabricated with an additional inner dome formed out of minimum 0.098 in. (2.5 mm) thick clear acrylic sheet material. Page 6 of 9

8.2 Bristolite Skylights TUFFLITE TRIARCH Model ALT-CM-1-PC and Model ALT-CM-2-CPC skylights described above meet the FM Approvals requirements for a 150 psf (7.2 kpa) wind uplift rating when secured to minimum 1.5 in. (38 mm) thick wood curb framing, with #10 self tapping stainless steel screws. Fasteners are secured through all four sides of the aluminum frame and spaced maximum 6 in. o.c. (152 mm). 8.3 Bristolite Skylights TUFFLITE TRIARCH Model ALT-CM-1-PC and Model ALT-CM-2-CPC skylights meet the FM Approvals requirements for a Severe Hail (SH) rating as tested with 2.0 in. (51 mm) diameter frozen ice balls. 8.4 Bristolite Skylights TUFFLITE TRIARCH Model ALT-CM-1-PC and Model ALT-CM-2-CPC skylights meet the criteria for a Spread of Flame Fire rating of Class A at a maximum slope of 1 in 12. 8.4.1 Fire tests indicate that if a sprinkler is installed directly under a TUFFLITE TRIARCH Model ALT-CM-1-PC and Model ALT-CM-2-CPC skylight, steps shall be taken to prevent the skylight from interfering with the sprinkler s operation. 8.5 Since an authorized Master Agreement exists, Approval is effective as of the date of this report. 8.6 Once Approval is effective, the above skylights will be listed in the Approval Guide, an online resource of FM Approvals. TESTING SUPERVISED BY: M. P. DeSousa PROJECT DATA RECORD: Project I.D. # 3044352 ORIGINAL TEST DATA: PDR for Project I.D. # 3044352 ATTACHMENTS: Appendix A (1 page), Appendix B (1 page) REPORT BY: REPORT REVIEWED BY: Michael P. DeSousa Engineer - Materials Group Jill E. Norcott, PE Technical Team Manager - Materials Group Page 7 of 9

Appendix A Page 8 of 9

Appendix B Page 9 of 9