CEILING CONCEALED SPLIT SYSTEM C SERIES

Similar documents
Space Saving. Comprehensive Product Range. Independent Circuit. Reliable & Efficient Rotary Compressor. Z - ODP (Zero Ozone Depletion Potential)

All Product Catalogue

Ceiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432K VRF HEAT PUMP

R410A TECHNICAL MANUAL. Inverter Single Split Series Air Conditioner. FTK-J, FTXN-J Series. Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2

All Product Catalogue

FDYMP-D, FDP-D, FGP-D, FDYP-E, FGYP-E

Low Static Pressure Duct(V shape evaporator)

TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS

DC INVERTER DUCTED AIR CONDITIONERS

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

modular multi intelligent, environmental and versatile

Models: 12 and 18. Models: 24 to 60

Driving and Connecting Globally. Fan Coil Unit. Model : PHW-K Size : 510CMH~2720CMH. Made in Taiwan

Others ( 50Hz areas ) ADVANCED SUBJECT DATE: Sep 12 PRODUCT NEWS Launching of new RPI-(2.0~6.0)FSN4E ducted indoor units series.

DUCTED INDOOR UNIT ENGINEERING MANUAL

Aesthetically Attractive Indoor unit. Enhanced with various Indoor Air Quality Features. Negative Ion Generator (Standard)

Compact Four-way Cassette Type

It is a kind of fan coil unit that is connected to the chillers to realize cooling/heating for civil or residential use.

Hitachi Multizone Heat Pump Air Conditioning

M1 TYPE SLIM VARIABLE STATIC PRESSURE HIDE AWAY CONCEALED DUCT

Four-Way Ceiling Cassette

Stylus 4G. Mini Split Air Conditioners. Stylus 4G Series Convertible Type 12,000-60,000 Btu/h MCX / MWX SERIES 50 Hz R22 / R410a

FFQN-C, FCRN-E, FFRN-C

INVERTER DUCTED SYSTEMS

R22 TECHNICAL MANUAL. Split Unit Air Conditioner Ceiling Cassette C & E Series FF-C, FHC-E, FFY-C, FHYC-E. Cooling only & Heatpump [50Hz]

Low Static Pressure Duct (V shape evaporator)

Rooftop Packaged Air Conditioners

PREMIUM INVERTER DUCTED AIR CONDITIONING

High Static Pressure Duct Fan Coil Unit

Landmark Rooftop Packaged Units

V33B High Efficiency 360 Cassette Indoor Models - 60HZ

WALL MOUNTED type SPLIT TYPE ROOM AIR CONDITIONER. Models

VMDA Concealed Medium Static Ducted Indoor Models - 60HZ

Model RAS-25YHA2 RAS-35YHA3 RAS-50YHA2 RAS-60YHA2 RAS-70YHA2 RAS-80YHA2

Digital Inverter 4 series

Concealed Ducted Split Series R22

Indoor Console. Slim Design This is only 199mm thick, the slimmest on the market. Its slim design easily integrates the unit into your décor.

VMDB Concealed Medium Static Ducted Indoor Models - 60HZ

Inverter Series [ INVERTER ] All Product Brochure

Technical Service Manual. TVR LX Systems Low Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph

STELLAR PLUS SPLIT-SYSTEM HEAT PUMPS EFH SERIES SEER. MODELS E*FH018 THRU E*FH060 Nominal Capacity: 18 thru 60 MBH DESCRIPTION FEATURES

SINGLE. Technical Data Book. 4Way Cassette S for Nordic (R410A, 50Hz) Model : AC***JN4CEH/EU (ODU: AC***JXSC*H/EU)

VHIA High-Static Ducted Indoor Units - 60HZ

Technical Support Division GD CHIGO HEATING & VENTILATION EQUIPMENT CO., LTD.

RESIDENTIAL & LIGHT COMMERCIAL AIR CONDITIONERS 2015 / 2016 EVERY BUILDING MATTERS

Amendment Sheet. Code : ADB-FR Date : Superceded : nil REFRIGERANT CIRCUIT DIAGRAM

Guide Specifications. General. Casing. Coil/Drain pan. Fan/Motor

HELV NEUE BD CN 90% 51pts

RCE13. Product Specifications. 13 SEER Electric / Electric Residential Packaged Unit. Refrigerant System. Cabinet Construction. Blower.

Service manual MIV V4+ Indoor units

Q7RE Series Single Packaged Heat Pump, Single Phase

PACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.

FULL DC INVERTER SYSTEMS INDIVIDUAL AND MODULAR CONSTRUCTION FLEXIBLE COMBINATIONS AIR CONDITIONING COMMERCIAL AIR CONDITIONERS SDV4 2014

technical data air conditioning systems Round Flow Cassette FXFQ-P9VEB

Engineering Data Book

AHN 064 to 304 EHN/CHN 064 to 304

LG Multi Split Air Conditioners

SPLIT TYPE ROOM AIR CONDITIONER WALL MOUNTED TYPE

VRF. Technical Data Book. Ceiling for America (R410A, 60Hz, HP) Model : AM***FNCDCH***

Four steps static pressure set-up Easy to combine with different types of air diffusers R22 & R407c replacement technology

VWMB Wall-Mounted Non-Ducted Indoor Models - 60HZ

Q7RE Series Single Packaged Heat Pump, Single Phase

DC INVERTER VRF SYSTEMS C-VRF

Technical Service Manual. TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph

13 SEER Light Commercial 3 Phase

RPGE13. Product Specifications. 13 SEER Gas / Electric Residential Packaged Unit. Refrigerant System. Heat Exchanger. Cabinet Construction.

RPHP13. Product Specifications. 13 SEER Heat Pump Residential Packaged Unit. Refrigerant System. Cabinet Construction. Blower. Controls.

Fan Coil Unit Product Catalogue

VRF. Technical Data Book. Duct S for Europe (R410, 50Hz)

AIR CONDITIONING Managing condensate

Multizone Multi Split systems

Ductless Split Systems

PRPDF14 PRODUCT SPECIFICATIONS 14 SEER DUAL FUEL PACKAGED UNIT REFRIGERANT SYSTEM HEAT EXCHANGER CABINET CONSTRUCTION ACCESSORIES WARRANTY BLOWER

40KQV. Direct expansion split system Inverter Cassette. Nominal Cooling capacity: 4,85-12,40 kw Nominal Heating capacity: 5,10-13,00 kw

Four-way Cassette Type

Split-Sky Air FDYP-B7 Concealed Ceiling Unit

13 SEER. Light Commercial 3 Phase Packaged Heat Pump. RHP13 Features and Benefits. Refrigerant System. Cabinet Construction. Blower.

PHCD-Series. Catalog

PCXAU1601. VRV AHU System STANDARD SERIES AHUR-CAVJ/DAVJ/DABVJ OUTDOOR AIR SERIES AHUR-CALJ/DALJ/DABLJ. Heat Pump 50/60 Hz R-410A

Contents. Carrier China

(Thin) (Ultrathin) Suspended Air-handling Unit

Technical Service Manual

Ductless Split Systems

V33A Standard/High Efficiency 360 Cassette Indoor Models - 60HZ

PRPHP14 PRODUCT SPECIFICATIONS 14 SEER HEAT PUMP PACKAGED UNIT REFRIGERANT SYSTEM CABINET CONSTRUCTION BLOWER CONTROLS INSTALLATION ACCESSORIES

From domestic to commercial applications you ll find the detail you need to pinpoint which ActronAir system is most appropriate for your needs.

indoor air quality and energy saving TECHNICAL DATA HRE-TOP EC VENTILATION UNIT WITH HEAT RECOVERY FOR COMMERCIAL AND INDUSTRIAL BUILDINGS

Chilled Water Vertical Fan Coils

COMMERCIAL // HEATING AND COOLING SYSTEMS EVERY OFFICE MATTERS

GQ5RD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Single Packaged Heat Pump, Single Phase 13 SEER, R-410A, WARRANTY

Product Brochure 2018

Product Data. CC5A, CD5A Heating/Cooling Coil. Sizes A018 thru W060 COMMON FEATURES

MODEL: DCT 35 INV-Si DCT 50 INV-Si DCT 70 INV-Si DCT 100 INV-Si DCT 140 INV-Si DCT 170 INV-Si

Air Conditioning Technical Data FXDQ-A3 > FXDQ15A3VEB > FXDQ20A3VEB > FXDQ25A3VEB > FXDQ32A3VEB > FXDQ40A3VEB > FXDQ50A3VEB > FXDQ63A3VEB

PRAC14 PRODUCT SPECIFICATIONS

2010 Duct-Free Splits Line Card

Ductless Systems. Right product for the right application. Fall 2015 Edition

ODYSSEY Product Catalogue Light Commercial Split System 5-20 Tons TTA/TTH/TWE Models 50 Hz

High Wall Type ( 2 Series )

Transcription:

CEILING CONCEALED SPLIT SYSTEM C SERIES

Microprocessor Controlled ith the microprocessor controlling the operation, the ACC model can offer comfortable room conditions according to the needs of the user. In addition, its control algorithms can provide protection to components of the air conditioning unit against any faults. Auto Random Restart During occasion of power failure, the unit will automatically restart according to the last setting condition when power resumed. Option is provided to cancel this feature. Double Protection Drainage System The primary drain pan is designed with high thermal insulation material and moulded in gradient for better condensate water drainage. The extra secondary drain pan built in to the standard unit offers extra protection against possible water leaking problems. Primary Drain Pan Polysterene (Ps) ith Height Impact Polystyrene (Hips) Cover Secondary Drain Pan ith Insulation FEATURES Flexibility In System Design The unit offers fan motor that can operate up to 4 speeds (Models A5CC 28C & above only), thus provide choices of external static pressure for designing ducting system. In addition, a range of ACCC model with optional specification of low external static pressure is also provided to cater for short duct application. Please refer to the technical specification of ACC model. Self Diagnosis Features The microprocessor provides the possibility to detect and to diagnose any faults that occur in the system. Faults are displayed as error code in the wired controller. This will ease the troubleshooting process. Duct Accessories (Optional) A set duct accessories specifically designed to fit and to suit the ACCC model is being created. Thus offers a one stop solution to installing the unit. * Available for ACC 1025 C/CR only Flexible Round Duct (field supply) Discharge Adaptor Square Grille Assembly c/w Adaptor Secondary Drain Pan with Insulation Ceiling Concealed Unit Square Return Grille Assembly c/w Adaptor & Filter Primary Drain Pan ACC Return Assembly Bracket c/w Adaptor Flexible Round Duct (field supply)

NIM Able The ACC range of product is able to communicate with the versatile NIM networking control module and offers the opportunity of one centralized control for a system of multiple indoor units in a building. Choices Of ired And ireless Controller SLM 3 AC5300 ireless Controller (Optional) Netare III Controller (Optional) Standard units come with a simple and user friendly SLM 3. An optional specification of ACCC series is also available that comes with Netware III, which offers wide range of control features that includes 7 days and 24 hours timer settings, self diagnosis error code display and more. In addition, an innovative and compact wireless controller (credit card size), AC5300, provides wireless command to the SLM 3 & NETARE III. R410A Refrigerant In line with Montreal Protocol A5CC series utilise the new R410A refrigerant. 50%R32 50%R125 Better Air Distribution The conditioned air can be effectively distributed to the room through the ducting and this ensures a pleasant environment for comfortable living. Multiple rooms can be cooled together at the same time by using just one unit of fan coil.

CEILING CONCEALED ACCC SERIES R22 HEAT PUMP MODEL NOMINAL COOLING CAPACITY NOMINAL HEATING CAPACITY ACC 10CR ACC 15CR ACC 20CR ACC 25CR ALC 10CR ALC 15CR ALC 18CR ALC 20CR ALC 25CR 12300 12000 18000 18500 19000 19800 23500 24000 3600 3515 5280 5420 5570 5800 6890 7030 NOMINAL TOTAL INPUT POER COOLING 900 1267 1910 1895 2616 (STANDARD) HEATING 894 1062 1750 1845 2536 NOMINAL TOTAL INPUT POER COOLING 894 1256 1894 1879 2589 (LO STATIC) HEATING 784 1051 1734 1829 2509 EER (STANDARD) / 3.17 2.94 2.87 3.05 COP (STANDARD) / 3.63 3.44 3.23 3.27 2.83 EER (LO STATIC) / 3.15 2.91 2.81 2.99 COP (LO STATIC) / 3.59 3.40 3.16 3.20 2.84 NOMINAL CAPACITY ACC 10C ACC 15C ACC 20C ACC 25C ALC 10C ALC 15C ALC 18C ALC 20C ALC 25C 12300 18000 19000 23500 3600 5280 5570 6890 NOMINAL TOTAL INPUT POER (STANDARD) 900 1267 1910 1895 2616 NOMINAL TOTAL INPUT POER (LO STATIC) 894 1256 1894 1879 2589 EER (STANDARD) / 3.17 2.94 2.87 3.05 EER (LO STATIC) / 3.15 2.91 2.81 2.99 POER SOURCE V/Ph/Hz 220 240 / 1 / 50 220 240 / 1 / 50 220 240 / 1 / 50 220 240 / 1 / 50 HIGH 142 / 300 241 / 510 316 / 670 382 / 810 AIR FLO MEDIUM 123 / 260 208 / 440 302 / 640 359 / 760 LO 104 / 220 170 / 360 278 / 590 288 / 610 HIGH 142 / 300 255 / 540 307 / 650 307 / 650 363 / 770 AIR FLO MEDIUM 118 / 250 222 / 470 303 / 640 303 / 640 340 / 720 (LO STATIC) LO 99 / 210 165 / 350 269 / 570 269 / 570 274 / 580 EXTERNAL STATIC PRESSURE (H/M/L) 49 / 39 / 29 49 / 39 / 20 69 / 65 / 42 41 / 31 / 18 (0.20 / 0.16 / 0.12) (0.20 / 0.16 / 0.08) (0.28 / 0.26 / 0.17) (0.16 / 0.12 / 0.07) EXTERNAL STATIC PRESSURE (LO STATIC, H/M/L) 20 / 9.8 / 4.9 (0.08 / 0.04 / 0.02) 29 / 20 / 9.8 (0.12 / 0.08 / 0.04) 25 / 15 / 5 (0.10 / 0.06 / 0.02) SOUND PRESSURE LEVEL (H/M/L) dba 33 / 30 / 26 37 / 34 / 29 38 / 36 / 34 38 / 36 / 34 40 / 39 / 36 HEIGHT 261 / 10.28 261 / 10.28 261 / 10.28 261 / 10.28 IDTH 765 / 30.12 905 / 35.63 1065 / 41.93 1200 / 47.24 411 / 16.18 411 / 16.18 411 / 16.18 411 / 16.18 EIGHT kg/lb 17 / 37.5 21 / 46.3 22 / 48.5 22 / 48.5 25 / 55.1 SOUND PRESSURE LEVEL dba 46 49 51 51 52 HEIGHT 540 / 21.3 654 / 25.7 756 / 29.8 IDTH 700 / 27.6 855 / 33.7 855 / 33.7 250 / 9.8 328 / 12.9 328 / 12.9 UNIT EIGHT kg/lb 32 / 70.5 57 / 125.7 59 / 130.1 62 / 136.7 LIQUID 6.35 / 1/4 6.35 / 1/4 6.35 / 1/4 6.35 / 1/4 9.52 / 3/8 GAS 9.52 / 3/8 12.70 / 1/2 15.88 / 5/8 15.88 / 5/8 HEAT PUMP MODEL NOMINAL COOLING CAPACITY NOMINAL HEATING CAPACITY 60HZ NOMINAL TOTAL INPUT POER (STANDARD) 1Ø <3Ø> NOMINAL TOTAL INPUT POER (LO STATIC) 1Ø <3Ø> EER (STANDARD) 1Ø <3Ø> COP (STANDARD) 1Ø <3Ø> EER (LO STATIC) 1Ø <3Ø> COP (LO STATIC) 1Ø <3Ø> NOMINAL TOTAL INPUT POER 1Ø <3Ø> EER 1Ø <3Ø> COP 1Ø <3Ø> NOMINAL CAPACITY 60HZ NOMINAL TOTAL INPUT POER (STANDARD) 1Ø <3Ø> NOMINAL TOTAL INPUT POER (LO STATIC) 1Ø <3Ø> EER (STANDARD) 1Ø <3Ø> EER (LO STATIC) 1Ø <3Ø> NOMINAL TOTAL INPUT POER 1Ø <3Ø> EER 1Ø <3Ø> POER SOURCE 1Ø <3Ø> AIR FLO AIR FLO (LO STATIC) ACC 28CR ACC 30CR ALC 28CR ALC 30CR ALC 28CR ALC 30CR 27000 30000 28000 30000 7913 8792 8602 8792 28000 30000 29000 30000 8206 8792 8499 8792 COOLING 2942 3090 <3070> 2997 3145 <3125> HEATING 2507 3060 <3040> 2562 3115 <3095> COOLING 3124 3116 <3096> HEATING 2700 3086 <3066> / 2.64 2.94 <2.86> 3.09 3.00 <3.02> / 3.23 2.97 <2.99> 3.62 3.03 <3.06> / 2.67 2.87 <2.89> / 3.21 2.90 <2.92> COOLING 2580 2620 HEATING 3082 3490 / 3.41 3.36 / 2.85 2.52 ACC 28C ACC 30C ALC 28C ALC 30C ALC 28C ALC 30C 27000 28000 28000 29000 7913 8206 8602 8493 2942 2821 <2981> 3153 2799 < 2855 > 3124 2770 <2826> / 2.64 3.01 <2.85> 3.09 3.29 < 3.22 > / 2.67 3.13 <3.06> 3292 3720 / 2.49 2.28 V/Ph/Hz 220 240 / 1 / 50 <380 415 / 3 / 50> SUPER HIGH 401 / 850 425 / 900 HIGH 382 / 810 392 / 830 MEDIUM 363 / 770 359 / 760 LO 335 / 710 335 / 710 SUPER HIGH 444 / 940 HIGH 415 / 880 MEDIUM 373 / 790 LO 349 / 740 EXTERNAL STATIC PRESSURE (H/M/L) 98 / 78 / 68 / 59 (0.39 / 0.31 / 0.28 / 0.24) 206 / 167 / 127 / 88 (0.83 / 0.67 / 0.51 / 0.35) EXTERNAL STATIC PRESSURE (LO STATIC, H/M/L) 49 / 39 / 29 / 20 (0.20 / 0.16 / 0.12 / 0.08) SOUND PRESSURE LEVEL (H/M/L) dba 44 / 41 / 38 / 34 49 / 46 / 42 / 38 HEIGHT 285 / 11.22 IDTH 1007 / 39.65 929 / 36.57 600 / 23.62 541 / 21.30 EIGHT kg/lb 38 / 83.8 39 / 86.0 SOUND PRESSURE LEVEL dba 54 58 54 58 HEIGHT 756 / 29.8 756 / 29.8 IDTH 855 / 33.7 855 / 33.7 328 / 12.9 400 / 15.75 328 / 12.9 400 / 15.75 UNIT EIGHT kg/lb 65 / 143.3 95 / 209.4 68 / 149.9 95 / 209.4 LIQUID GAS 9.52 / 3/8 9.52 / 3/8 15.88 / 5/8 15.88 / 5/8 ACC 38CR ALC 35CR ALC 40CR 35000 38000 10257 11137 36000 38500 10550 11280 3572 3766 <3736> 3303 3476 <3436> 3.38 3.19 <3.21> 3.48 3.52 <3.55> 3130 3787 3.56 2.98 ACC 38C ALC 35C ALC 40C 35000 35000 10257 10257 3443 3706 < 3656 > 3.23 2.99 < 3.03 > 4087 2.51 727 / 1540 694 / 1470 670 / 1420 637 / 1350 137 / 118 / 108 / 88 (0.55 / 0.47 / 0.43 / 0.35) 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER ITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151. 3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELO : a) COOLING 27 C DB / 19 C B INDOOR AND 35 C DB / 24 C B OUTDOOR b) HEATING 20 C DB INDOOR AND 7 C DB / 6 C B OUTDOOR 4) SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS B 8616 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.5m BELO THE CENTER OF THE UNIT. TESTED ITH 2m DUCT LENGTH AT THE AIR DISCHARGE OUTLET AND 1m DUCT LENGTH AT THE AIR RETURN INLET. 5) EER/COP CALCULATION IS BASED ON EFFECTIVE POER INPUT AS PER ISO 5151. 55 / 51 / 48 / 45 305 / 12.01 1302 / 51.26 638 / 25.12 41 / 90.4 58 58 400 / 15.75 95 / 209.4 100 / 220.5 9.52 / 3/8 19.05 / 3/4

CEILING CONCEALED ACCC SERIES R22 HEAT PUMP MODEL NOMINAL COOLING CAPACITY NOMINAL HEATING CAPACITY ACC 40CR ACC 50CR ACC 60CR ALC 35CR ALC 40CR ALC 50CR ALC 61CR 33500 35000 40000 40000 50000 53000 56000 56000 9818 10257 11723 11723 14654 15533 16410 16410 NOMINAL TOTAL INPUT POER COOLING 3265 3728 <3698> <5047> <6010> (STANDARD) 1Ø <3Ø> HEATING 3265 3438 <3408> <4447> <4980> NOMINAL TOTAL INPUT POER COOLING 3210 3673 <3643> 4956 5884 (LO STATIC) 1Ø <3Ø> HEATING 3210 3183 <3153> 4356 4854 EER (STANDARD) 1Ø <3Ø> / 3.30 3.41 <3.44> <3.11> <2.91> COP (STANDARD) 1Ø <3Ø> / 3.45 3.73 <3.76> <3.78> <3.57> EER (LO STATIC) 1Ø <3Ø> / 3.12 3.25 <3.28> 3.03 2.85 COP (LO STATIC) 1Ø <3Ø> / 3.26 3.53 <3.57> 3.67 3.46 NOMINAL TOTAL INPUT POER COOLING 3100 4160 5550 1Ø <3Ø> HEATING 3800 4623 5937 EER 1Ø <3Ø> / 3.78 3.52 2.96 COP 1Ø <3Ø> / 3.09 3.36 2.76 NOMINAL CAPACITY ACC 40C ACC 50C ACC 60C ALC 35C ALC 40C ALC 50C ALC 61C 33500 38500 47000 56000 9811 11276 13765 16410 NOMINAL TOTAL INPUT POER (STANDARD) 1Ø <3Ø> 3405 3555 < 3505 > < 4974 > < 6006 > NOMINAL TOTAL INPUT POER (LO STATIC) 1Ø <3Ø> 3350 3500 <3450> 4883 5880 EER (STANDARD) 1Ø <3Ø> / 3.16 3.46 < 3.51 > < 2.97 > <2.92> EER (LO STATIC) 1Ø <3Ø> / 2.99 3.28 <3.33> < 2.9 > < 2.85 > NOMINAL TOTAL INPUT POER 1Ø <3Ø> 4110 5233 6837 EER 1Ø <3Ø> / 2.74 2.63 2.40 POER SOURCE 1Ø <3Ø> SUPER HIGH V/Ph/Hz 519 / 1100 220 240 / 1 / 50 <380 415 / 3 / 50> 750 / 1590 779 / 1650 AIR FLO HIGH 500 / 1060 651 / 1380 722 / 1530 MEDIUM 467 / 990 604 / 1280 675 / 1430 AIR FLO (LO STATIC) LO SUPER HIGH HIGH MEDIUM LO 425 / 900 562 / 1190 500 / 1060 472 / 1000 458 / 970 571 / 1210 713 / 1510 628 / 1330 618 / 1310 599 / 1270 609 / 1290 802 / 1700 765 / 1620 717 / 1520 693 / 1470 60 HZ 60 HZ EXTERNAL STATIC PRESSURE (H/M/L) EXTERNAL STATIC PRESSURE (LO STATIC, H/M/L) 206 / 176 / 127 / 93 (0.83 / 0.71 / 0.51 / 0.37) 49 / 39 / 29 / 20 (0.20 / 0.16 / 0.12 / 0.08) SOUND PRESSURE LEVEL (H/M/L) dba 51 / 49 / 45 / 41 53 / 52 / 50 / 47 55 / 53 / 50 / 47 EIGHT HEIGHT IDTH kg/lb 1045 / 41.14 541 / 21.30 42 / 92.6 1299 / 51.14 541 / 21.30 54 / 119.1 1499 / 59.02 541 / 21.30 62 / 163.7 SOUND PRESSURE LEVEL dba 58 58 58 61 HEIGHT IDTH 400 / 15.75 400 / 15.75 460 / 18.1 UNIT EIGHT kg/lb 95 / 209.4 100 / 220.5 105 / 231.49 108 / 238.10 LIQUID 9.52 / 3/8 9.52 / 3/8 12.70 / 1/2 GAS 19.05 / 3/4 19.05 / 3/4 19.05 / 3/4 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER ITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151. 3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELO : a) COOLING 27 C DB / 19 C B INDOOR AND 35 C DB / 24 C B OUTDOOR b) HEATING 20 C DB INDOOR AND 7 C DB / 6 C B OUTDOOR 4) SOUND PRESSURE LEVEL ARE MEASURED IN AN ANECHOIC CHAMBER, ACCORDING TO JIS B 8616 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.5m BELO THE CENTER OF THE UNIT. 176 / 157 / 137 / 108 (0.71 / 0.63 / 0.55 / 0.43) 78 / 59 / 39 / 20 (0.31 / 0.24 / 0.16 / 0.08) 176 / 157 / 137 / 98 (0.71 / 0.63 / 0.55 / 0.39) 69 / 49 / 29 / 20 (0.28 / 0.20 / 0.12 / 0.08)

CEILING CONCEALED A5CCC SERIES R410A HEATPUMP MODEL NOMINAL COOLING CAPACITY 1Ø <3Ø> NOMINAL HEATING CAPACITY 1Ø <3Ø> A5CC 10CR A5CC 15CR 12500 12000 A5CC 20CR 18000 <18000> 18500 <18500> A5CC 25CR 21000 <22860> 22000 <23200> A5LC 10CR A5LC 15CR 3660 3520 A5LC 20CR 5280 <5280> 5420 <5420> A5LC 25CR 6155 <6700> 6450 <6800> NOMINAL TOTAL INPUT POER COOLING 961 1297 1757 <1791> 2003 <2274> 1Ø <3Ø> HEATING 813 1147 1597 <1561> 1953 <2167> EER 1Ø <3Ø> / 2.96 2.91 3.13 <3.07> 3.15 <3.02> COP 1Ø <3Ø> / 3.52 3.18 3.55 <3.64> 3.39 <3.22> A5CC 25C A5LC 25C NOMINAL CAPACITY 1Ø <3Ø> A5CC 10C A5CC 15C A5CC 20C A5LC 10C A5LC 15C A5LC 20C 12500 18000 <18000> 3660 5280 <5280> 961 1297 1757 <1791> / 2.96 2.91 3.13 <3.07> 21000 <22860> 6155 <6700> NOMINAL TOTAL INPUT POER 1Ø <3Ø> 2003 <2274> EER 1Ø <3Ø> 3.15 <3.02> POER SOURCE 1Ø <3Ø> V/Ph/Hz 220 240 / 1 / 50 220240/1/50 <380415/3/50> HIGH 142 / 300 241 / 510 330 / 700 345 / 730 AIR FLO MEDIUM 123 / 260 208 / 440 321 / 680 340 / 720 LO 104 / 220 170 / 360 293 / 620 274 / 580 EXTERNAL STATIC PRESSURE (H/M/L) 49 / 39 / 29 (0.20 / 0.16 / 0.12) 49 / 39 / 20 (0.20 / 0.16 / 0.08) 64 / 58 / 34 (0.30 / 0.20 / 0.10) 55 / 39 / 29 (0.20 / 0.20 / 0.10) SOUND PRESSURE LEVEL (H/M/L) dba 33 / 30 / 26 37 / 34 / 29 38 / 36 / 34 40 / 39 / 36 HEIGHT 261 / 10.28 261 / 10.28 261 / 10.28 261 / 10.28 IDTH 765 / 30.12 905 / 35.63 1065 / 41.93 1200 / 47.24 411 / 16.18 411 / 16.18 411 / 16.18 411 / 16.18 EIGHT kg/lb 17 / 37.5 21 / 46.3 22 / 48.5 25 / 55.1 SOUND PRESSURE LEVEL dba 46 49 52 52 HEIGHT 540 / 21.3 654 / 25.7 756 / 29.8 IDTH 700 / 27.6 855 / 33.7 855 / 33.7 250 / 9.8 328 / 12.9 328 / 12.9 UNIT EIGHT kg/lb 32 / 70.5 59 / 130.1 62 / 136.7 LIQUID 6.35 / 1/4 6.35 / 1/4 6.35 / 1/4 6.35 / 1/4 GAS 9.52 / 3/8 12.70 / 1/2 12.70 / 1/2 15.88 / 5/8 HEATPUMP MODEL NOMINAL COOLING CAPACITY 1Ø <3Ø> NOMINAL HEATING CAPACITY 1Ø <3Ø> A5CC 28CR 26000 <27000> 26000 <28000> A5CC 38CR 32000 <33000> 34000 <36000> <39000> <42000> A5CC 50CR <48000> <49000> A5CC 60CR <54500> <57000> A5LC 28CR 7620 <7910> 7620 <8210> A5LC 35CR 9380 <9670> 9960 <10550> A5LC 40CR <11430> <12310> A5LC 50CR <14070> <14360> A5LC 61CR <15970> <16710> NOMINAL TOTAL INPUT POER COOLING 2892 <2876> 3287 <3427> <4173> <5115> <5765> 1Ø <3Ø> HEATING 2429 <2528> 2987 <3137> <4203> <4535> <5685> EER 1Ø <3Ø> / 2.73 <2.85> 3.07 <3.03> <2.88> <2.94> <2.98> COP 1Ø <3Ø> / 3.27 <3.38> 3.62 <3.64> <3.08> <3.42> <3.16> NOMINAL CAPACITY 1Ø <3Ø> A5CC 28C A5CC 38C A5CC 50C A5CC 60C A5LC 28C A5LC 35C A5LC 40C A5LC 50C A5LC 61C 26000 <27000> 32000 <33000> <39000> <48000> <54500> 7620 <7910> 9380 <9670> <11430> <14070> <15970> NOMINAL TOTAL INPUT POER 1Ø <3Ø> 2892 <2876> 3287 <3427> <4173> <5115> <5765> EER 1Ø <3Ø> / 2.73 <2.85> 3.07 <3.03> <2.88> <2.94> <2.98> POER SOURCE 1Ø <3Ø> V/Ph/Hz 220240/1/50 <380415/3/50> SUPER HIGH 401 / 850 604 / 1280 675 / 1430 812 / 1720 AIR FLO HIGH 382 / 810 547 / 1160 623 / 1320 732 / 1550 MEDIUM 363 / 770 496 / 1050 580 / 1230 632 / 1340 LO 335 / 710 434 / 920 533 / 1130 552 / 1170 EXTERNAL STATIC PRESSURE (SH/H/M/L) 98 / 78 / 68 / 59 (0.39 / 0.31 / 0.28 / 0.24) 118 / 96 / 78 / 61 (0.47 / 0.39 / 0.31 / 0.24) 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER ITHOUT PRIOR NOTICE. 2) ALL UNITS ARE BEING TESTED AND COMPLY TO ISO 5151. 3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELO : a) COOLING 27 C DB / 19 C B INDOOR AND 35 C DB / 24 C B OUTDOOR b) HEATING 20 C DB INDOOR AND 7 C DB / 6 C B OUTDOOR 4) SOUND PRESSURE LEVEL ARE ACCORDING TO JIS B 8616 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.5m BELO THE CENTER OF THE UNIT. TESTED ITH 2m DUCT LENGTH AT THE AIR DISCHARGE OUTLET AND 1m DUCT LENGTH AT THE AIR RETURN INLET. 5) EER/COP CALCULATION IS BASED ON EFFECTIVE POER INPUT AS PER ISO 5151. 147 / 126 / 109 / 92 147 / 120 / 90 / 69 (0.59 / 0.50 / 0.44 / 0.37) (0.59 / 0.48 / 0.36 / 0.28) SOUND PRESSURE LEVEL (SH/H/M/L) dba 44 / 41 / 38 / 34 52 / 49 / 48 / 45 54 / 53 / 52 / 51 54 / 52 / 50 / 46 HEIGHT 285 / 11.22 305 / 12.0 378 / 14.9 378 / 14.9 IDTH 1007 / 39.65 1302 / 51.3 1299 / 51.1 1499 / 59.0 600 / 23.62 638 / 25.1 541 / 21.3 541 / 21.3 EIGHT kg/lb 38 / 84 41 / 90 54 / 119 62 / 137 SOUND PRESSURE LEVEL dba 54 58 68 65 HEIGHT 756 / 29.8 IDTH 855 / 33.7 328 / 12.9 400 / 15.75 400 / 15.75 460 / 18.1 UNIT EIGHT kg/lb 68 / 149.9 95 / 209.4 100 / 220.5 105 / 231.5 108 / 238.1 LIQUID 9.52 / 3/8 9.52 / 3/8 9.52 / 3/8 9.52 / 3/8 GAS 15.88 / 5/8 15.88 / 5/8 15.88 / 5/8 19.05 / 3/4 2009 Acson International APACCC09 www.acsoninternational.com