Space Saving. Comprehensive Product Range. Independent Circuit. Reliable & Efficient Rotary Compressor. Z - ODP (Zero Ozone Depletion Potential)
|
|
- Linda Morton
- 6 years ago
- Views:
Transcription
1 MULTI SPLIT SYSTEMS
2 Space Saving Only 1 outdoor is needed to couple with 2 or more indoors. Thus, this has effectively improved the floor space utilisation. The Multi-Split models are especially popular in apartments and condominiums where the floor space is very limited. Comprehensive Product Range Acson offers a very comprehensive range of Multi-Split condensing units, right from System 2 (1 outdoor to 2 indoors) up to System 3. In addition, each of the product range has various cooling/heating capacity combinations. Independent Circuit Each indoor unit has its own individual piping and compressor that runs independently. By this, cooling and heating performance are never compromised when system is running maximum number of indoor units. (applicable for AMSD-A/AR & AMST-A/AR ) Reliable & Efficient Rotary Compressor The reliable rotary compressor, which can efficiently providing an optimum cooling/heating capacity, is being used in the system. Z - ODP (Zero Ozone Depletion Potential) The AMSD and AMST Series are also available using the ozone-friendly refrigerant. Multi Split Schematic AMSD Series: Double Compressor 2-Indoor Split System AMST Series: Triple Compressor 3-Indoor Split System COMP. A A COMP. A A COMP. B B COMP. B B COMP. C C ide Range Of Indoor Coupling Models Acson's Multi-Split systems also include ACC-C and ACK-C for added flexibility. * (Applicable for AMSD-A and AMST-A cooling only models). ACK-C ACC-C
3 Aesthetically Attractive Indoor unit The indoor unit AM-G series comes with a stylish outlook and double louver design which can blend easily into any interior decoration and design. Enhanced with various Indoor Air Quality Features - Effectively Inactivate & Eliminate Various Harmful Airborne Elements 99.9% bacteria free, no more worries Acson is focused on developing new and exciting products to improve everyday living environment of the 21st century. The all-new NanoShield combines powerful sterilizing and deodorizing effect of NanoSilver and Nano-Photocatalyst. Silver is used from the days of Hippocrates (Father of Medicine) as a healing agent and its use has been expanded into anti-bacterial applications ever since. Modern nanotechnology provides through full-infusion onto the filters and larger coated surface area. ith this, deodorizing power is 150 times stronger whereas filtration is 20 times more effective. NanoPhotocatalyst - devocs & deodorization (150 times stronger than high performance activated carbon) NanoSilver -bacteria & germs elimination Pre Filter Negative Ion Generator (Standard) The Ion Generator releases negative ion shower to create a refreshing and clean environment as if you are fallen into the world of nature. Non Thermal Plasma (NTP) Air Sterilizer The NTP will decomposes the Oxygen molecule (O2) into two electrically charged oxygen atoms (O*) with higher energy potential. These O* atoms can neutralize a wide range of odours (i.e. cigarette smoke, household odours and mould odours) into harmless substances (i.e. H2O, CO2 and acid). Its oxidable characteristics also can damage the cell structure of micro-organism (i.e. bacterial, dust mites, germs, mould and yeast), create a climate of clean and healthy air in rooms and indoor spaces. This is an optional specification. Please refer to your local agent/dealer for product with this specification. Easy-To-Use LCD Remote Controller The unique design of G12 handset comes as standard for all AM-G series indoor which includes Real Time Timer Turbo Mode Personalized Setting Control Other Advance Features The indoor unit is also equipped with may advance features such as: 24 Hours Real Time Timer Sleep Mode Auto Control Hydrophilic Slit Fin 3 Speed Fan Control Auto Fan Speed Control Self Diagnosis Features Auto Random Restart
4 MULTI- SPLIT AMSD-A SERIES ITH ALL MOUNTED-R22 HEAT PUMP MODEL NOMINAL HEATING CAPACITY 50HZ NOMINAL POER INPUT- COOLING 50 HZ POER SOURCE NOMINAL POER INPUT- HEATING NOMINAL TOTAL INPUT POER AIR FLO AM10GR AM15GR Btu/h 2 x x Btu/h 2 x x ONE UNIT RUNNING TO UNITS RUNNING ONE UNIT RUNNING TO UNITS RUNNING AM10G AM15G Btu/h 2 x x ONE UNIT RUNNING TO UNITS RUNNING (H/M/L) UNIT EIGHT UNIT EIGHT LO l/s / cfm / / / 345 l/s / cfm / / / 285 l/s / cfm / / / / 34 / / 34 / / 36 / AMSD1010AR 2 x AM10GR AMSD1010A 2 x AM10G / AMSD1015AR AMSD1015A / / / / / / / GAS 2 x 9.52 / 2 x 3/ / 3/ / 1/2 AMSD1515AR 2 x AM15GR 2 x x x x AMSD1515A 2 x AM15G 2 x x / / / / 36 / / x 12.7 / 2 x 1/2 MULTI- SPLIT AMSD-A SERIES ITH ALL MOUNTED-R22 HEAT PUMP MODEL NOMINAL HEATING CAPACITY 50HZ 50 HZ NOMINAL POER INPUT- COOLING NOMINAL POER INPUT- HEATING NOMINAL TOTAL INPUT POER POER SOURCE AIR FLO LO (H/M/L) UNIT EIGHT UNIT EIGHT AMSD1020AR AMSD1520AR AM10GR AM20GR AM15GR AM20GR Btu/h Btu/h ONE UNIT RUNNING TO UNITS RUNNING 3460 ONE UNIT RUNNING TO UNITS RUNNING 3475 AMSD1020A AMSD1520A AM10G AM20G AM15G AM20G Btu/h ONE UNIT RUNNING TO UNITS RUNNING l/s / cfm / / / / 490 l/s / cfm / / / / 410 l/s / cfm / / / / / 34 / / 40 / / 36 / / 40 / / / / / / / / / / / / / / / NOT AVALIALBLE / / / / / / 1/4 GAS 9.52 / 3/ / 5/ / 1/ / 5/8 MMSD2020AR 2 x MM020GR NOT AVALIALBLE AMSD2020A 2 x AM20G / / / / 40 / / / / / / x / 2 x 5/8 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER ITHOUT PRIOR NOTICE. 3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELO : a) COOLING - 27 C DB / 19 C B INDOOR AND 35 C DB / 24 C B OUTDOOR b) HEATING - 20 C DB INDOOR AND 7 C DB / 6 C B OUTDOOR 4) ARE ACCORDING TO JIS C 9612 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 0.8m BELO THE UNIT. S1
5 MULTI-SPLIT AMST-A SERIES ITH ALL MOUNTED-R22 HEAT PUMP MODEL NOMINAL HEATING CAPACITY 50 Hz AMST101010AR AMST151515AR 3 x AM10GR 2 x AM10GR AM15GR AM10GR 2 x AM15GR 3 x AM15GR 2 x AM10GR AM20GR Btu/h 3 x x x x x x x x 3520 Btu/h 3 x x x x x x x x 3220 COOLING HEATING AMST101010A AMST151515A 3 x AM10G 2 x AM10G AM15G AM10G 2 x AM15G 3 x AM15G 2 x AM10G AM20G Btu/h 3 x x x x x x x x x x Hz NOMINAL TOTAL INPUT POER POER SOURCE NOMINAL TOTAL INPUT POER AIR FLO UNIT EIGHT UNIT EIGHT LO (H/M/L) l/s / cfm / / / / / / / / 490 l/s / cfm / / / / / / / / 410 l/s / cfm / / / / / / / / / 34 / / 34 / / 36 / / 34 / / 36 / / 36 / / 34 / / 40 / / / / / / / / / / / / / / / AMST101015AR AMST101015A AMST101515AR AMST101515A / / / x 6.35 / 3 x 1/4 3 x 6.35 / 3 x 1/4 3 x 6.35 / 3 x 1/4 3 x 6.35 / 3 x 1/4 AMST101020AR NOT AVAILABLE AMST101020A 3 x 6.35 / 3 x 1/4 GAS 3 x 9.52 / 3 x 3/8 2 x 9.52 / 2 x 3/ / 1/ / 3/8 2 x 12.7 / 2 x 1/2 3 x 12.7 / 3 x 1/2 2 x 9.52 / 2 x 3/ / 1/ / MULTI-SPLIT AMST-A SERIES ITH ALL MOUNTED-R22 50 Hz NOMINAL TOTAL INPUT POER POER SOURCE AIR FLO UNIT EIGHT LO (H/M/L) UNIT EIGHT 2 x AM10G AM25G AM10G AM15G AM25G 2 x AM15G Btu/h 2 x x l/s / cfm / / / / / / 345 l/s / cfm / / / / / / 285 l/s / cfm / / / / / / / 34 / / 43 / / 34 / / 36 / / 43 / / 36 / / / / / / / / / / / / / / / / / / AMST101025A / x 6.35 / 3 x 1/4 AMST101525A GAS 2 x 9.52 / 2 x 3/ / 5/ / 3/ / 1/ / 5/8 2 x 12.7 / 2 x 1/ / x 6.35 / 3 x 1/4 850 / / / ) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER ITHOUT PRIOR NOTICE. 3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELO : a) COOLING - 27 C DB / 19 C B INDOOR AND 35 C DB / 24 C B OUTDOOR b) HEATING - 20 C DB INDOOR AND 7 C DB / 6 C B OUTDOOR 4) ARE ACCORDING TO JIS C 9612 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 0.8m BELO THE UNIT. AMST151525A / x 6.35 / 3 x 1/4 AM25G / / / / 43 / / / / / / 5/8 S2
6 MULTISPLIT AMSD-A SERIES ITH CEILING CASSETTE 50 Hz NOMINAL TOTAL INPUT POER POER SOURCE FAN AIR FLO ( ) - PANEL EIGHT (UNIT+PANEL) ACK10C ACK10C ACK10C ACK15C ACK15C ACK15C Btu/h NOT AVAILABLE l/s / cfm 194 / / / / (295) / 9.8 (11.6) 250 (295) / 9.8 (11.6) 250 (295) / 9.8 (11.6) kg / ( ) / ( ) / ( ) / / / 13 UNIT EIGHT kg/ lb 63 / / / AMSD1010A AMSD1015A / 1/ / 1/ / 1/4 AMSD1515A 250 (295) / 9.8 (11.6) GAS 9.52 / 3/ / 3/ / 1/ / 1/ / ( ) 6.35 / 1/4 MULTISPLIT AMSD-A SERIES ITH CEILING CASSETTE 50 Hz NOMINAL TOTAL INPUT POER POER SOURCE FAN AIR FLO ACK10C ACK20C ACK15C ACK20C ACK20C ACK20C Btu/h l/s / cfm 194 / / / / ( )-PANEL EIGHT (UNIT+PANEL) UNIT EIGHT kg / ( ) / ( ) / ( ) / ( ) / 17.2 kg / lb AMSD1020A AMSD1520A AMSD2020A (295) / 9.8 (11.6) 632 / / / / / / FITTING 6.35 / 1/ / 1/ / 1/4 GAS 9.52 / 3/ / 5/ / 1/ / 5/8 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER ITHOUT PRIOR NOTICE. 3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELO : a) COOLING - 27 C DB / 19 C B INDOOR AND 35 C DB / 24 C B OUTDOOR b) HEATING - 20 C DB INDOOR AND 7 C DB / 6 C B OUTDOOR 4) ARE ACCORDING TO JIS C 9612 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 0.8m BELO THE UNIT / / ( ) 6.35 / 1/ / 5/8 S3
7 MULTISPLIT AMST-A SERIES ITH CEILING CASSETTE Btu/h 50 HZ NOMINAL TOTAL INPUT POER POER SOURCE FAN AIR FLO ( )-PANEL EIGHT (UNIT+PANEL) UNIT EIGHT GAS l/s / cfm AMST101010A AMST101015A AMST101515A AMST151515A 3 x ACK10C 2 x ACK10C ACK15C ACK10C 2 x ACK15C 3 x ACK15C 2 x ACK10C ACK20C 3 x x x x x x x x x x / (295) / 9.8 (11.6) 250 (295) / 9.8 (11.6) 250 (295) / 9.8 (11.6) 250 (295) / 9.8 (11.6) kg/ lb kg/ lb 212 / / ( ) / ( ) / ( ) / ( ) / ( ) / ( ) / ( ) / ( ) / / / / / / / AMST101020A 250 (295) / 9.8 (11.6) 104 / / 1/ / 1/ / 1/ / 1/ / 1/ / 1/ / 1/ / 1/ / 3/ / 3/ / 1/ / 3/ / 1/ / 1/ / 3/ / 5/8 61 MULTISPLIT AMST-A SERIES ITH CEILING CASSETTE Btu/h 50 HZ NOMINAL TOTAL INPUT POER POER SOURCE FAN AIR FLO ( )-PANEL EIGHT (UNIT+PANEL) l/s / cfm kg/ lb AMST101025A AMST101525A AMST151525A 2 x ACK010C ACK25A ACK10C ACK15C ACK25A 2 x ACK15C ACK25A 2 x x x x / / / / / / / (295) / 9.8 (11.6) 335 (363) / 13.2 (14.3) 250 (295) / 9.8 (11.6) 250 (295) / 9.8 (11.6) 335 (363) / 13.2 (14.3) 250 (295) / 9.8 (11.6) 335 (363) / 13.2 (14.3) 820 (930) / 32.2 (36.6) 820 (930) / 32.2 (36.6) 820 (930) / 32.2 (36.6) 820 (930) / 32.2 (36.6) 820 (930) / 32.2 (36.6) 820 (930) / 32.2 (36.6) / ( ) / ( ) / ( ) / ( ) / ( ) / ( ) / ( ) / UNIT EIGHT kg/ lb 1030 / / / / / GAS 6.35 / 1/ / 3/ / 1/ / 1/ / 3/ / 1/ / 3/ / 3/ / 5/ / 3/ / 1/ / 5/ / 1/ / 5/8 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER ITHOUT PRIOR NOTICE. 3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELO : a) COOLING - 27 C DB / 19 C B INDOOR AND 35 C DB / 24 C B OUTDOOR b) HEATING - 20 C DB INDOOR AND 7 C DB / 6 C B OUTDOOR 4) ARE ACCORDING TO JIS C 9612 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.4m BELO FASCIA. S4
8 MULTISPLIT AMSD-A SERIES ITH CEILING CONCEALED AMSD1010A AMSD1015A AMSD1515A ACC10C ACC10C ACC10C ACC15C ACC15C ACC15C Btu/h HZ NOMINAL TOTAL INPUT POER POER SOURCE 300 / / / / 241 AIR FLO 260 / / / / 208 STD STATIC LO 220 / / / / 170 STATIC PRESSURE H/M/L mm Aq (Pa) 5 / 4 / 3 ( 49 / 39 / 29 ) 270 / / / / 255 LO STATIC AIR FLO 250 / / / / 222 LO 210 / / / / 165 STATIC PRESSURE H/M/L mm Aq (Pa) 2 / 1 / 0.5 ( 20 / 9.8 / 4.9 ) ( H/M/L ) 33 / 30 / / 30 / / 34 / / 34 / / / / / / / / / / / / / EIGHT 17 / / / / / / / 13 EIGHT 63 / / / / 1/ / 1/ / 1/ / 1/4 GAS 9.52 / 3/ / 3/ / 1/ / 1/2 MULTISPLIT AMSD-A SERIES ITH CEILING CONCEALED 50 HZ NOMINAL TOTAL INPUT POER POER SOURCE STD STATIC LO STATIC ACC10C ACC20C ACC15C ACC20C ACC20C ACC20C Btu/h / / / / / / / / 321 LO 220 / / / / 293 STATIC PRESSURE H/M/L mm Aq (Pa) 5 / 4 / 3 ( 49 / 39 / 29 ) 6.5 / 6 / 4 (64 / 58 / 40) 5 / 4 / 3 ( 49 / 39 / 29 ) 6.5 / 6 / 4 (64 / 58 / 40) 270 / / / / / / / / 303 LO 210 / / / / 269 STATIC PRESSURE H/M/L mm Aq (Pa) 2 / 1 / 0.5 ( 20 / 9.8 / 4.9 ) 3 / 2 / 1 ( 29 / 20 / 9.8 ) 2 / 1 / 0.5 ( 20 / 9.8 / 4.9 ) 3 / 2 / 1 ( 29 / 20 / 9.8 ) ( H/M/L ) 33 / 30 / / 36 / / 34 / / 36 / / 36 / 34 EIGHT AIR FLO AIR FLO EIGHT 261 / / / / / / / / / / / / / / / / / 17.2 AMSD1020A / AMSD1520A 632 / / / / FITTING 6.35 / 1/ / 1/ / 1/4 GAS 9.52 / 3/ / 5/ / 1/ / 5/8 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER ITHOUT PRIOR NOTICE. 3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELO : a) COOLING - 27 C DB / 19 C B INDOOR AND 35 C DB / 24 C B OUTDOOR b) HEATING - 20 C DB INDOOR AND 7 C DB / 6 C B OUTDOOR 4) ARE ACCORDING TO JIS B 8616 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.5m BELO THE CENTER OF THE UNIT. TESTED ITH 2m DUCT LENGTH AT THE AIR DISCHARGE OUTLET AND 1m DUCT LENGTH AT THE AIR RETURN INLET AMSD2020A / / / / 6 / 4 (64 / 58 / 40) 650 / / / / 2 / 1 ( 29 / 20 / 9.8 ) 261 / / / / / / 1/ / 5/8 S5
9 MULTISPLIT AMST-A SERIES ITH CEILING CONCEALED Btu/h 50 HZ NOMINAL TOTAL INPUT POER POER SOURCE STD STATIC LO STATIC LO STATIC PRESSURE H/M/L LO STATIC PRESSURE H/M/L ( H/M/L ) EIGHT EIGHT AIR FLO AIR FLO GAS mm Aq (Pa) mm Aq (Pa) AMST101010A AMST101015A AMST101515A AMST151515A AMST101020A 3 x ACC10C 2 x ACC10C ACC15C ACC10C 2 x ACC15C 3 x ACC15C 2 x ACC10C ACC20C 3 x x x x x x x x x x / / / / / / / / / / / / / / / / / / / / / / / / / 4 / 3 ( 49 / 39 / 29 ) 6.5 / 6 / 4 (64 / 58 / 40) 270 / / / / / / / / / / / / / / / / / / / / / / / / / 1 / 0.5 ( 20 / 9.8 / 4.9 ) 3 / 2 / 1 ( 29 / 20 / 9.8 ) 33 / 30 / / 30 / / 34 / / 30 / / 34 / / 34 / / 30 / / 36 / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / 1/ / 1/ / 1/ / 1/ / 1/ / 1/ / 1/ / 1/ / 3/ / 3/ / 1/ / 3/ / 1/ / 1/ / 3/ / 5/8 MULTISPLIT AMST-A SERIES ITH CEILING CONCEALED Btu/h 50 HZ NOMINAL TOTAL INPUT POER POER SOURCE STD STATIC LO STATIC EIGHT AIR FLO LO STATIC PRESSURE H/M/L AIR FLO LO STATIC PRESSURE H/M/L ( H/M/L ) EIGHT GAS mm Aq (Pa) mm Aq (Pa) AMST101025A AMST101525A AMST151525A ACC10C x 2 ACC25C ACC10C ACC15C ACC25C ACC15C x 2 ACC25C 2 x x x x / / / / / / / / / / / / / / / / / / / / / / 4 / 3 ( 49 / 39 / 29 ) 5.5 / 4 / 3 (55 / 39 / 29) 5 / 4 / 3 ( 49 / 39 / 29 ) 5.5 / 4 / 3 (55 / 39 / 29) 5 / 4 / 3 ( 49 / 39 / 29 ) 5.5 / 4 / 3 (55 / 39 / 29) 270 / / / / / / / / / / / / / / / / / / / / / / 1 / 0.5 ( 20 / 9.8 / 4.9 ) 3 / 2 / 1 ( 29 / 20 / 9.8 ) 2 / 1 / 0.5 ( 20 / 9.8 / 4.9 ) 3 / 2 / 1 ( 29 / 20 / 9.8 ) 2 / 1 / 0.5 ( 20 / 9.8 / 4.9 ) 3 / 2 / 1 ( 29 / 20 / 9.8 ) 33 / 30 / / 39 / / 30 / / 34 / / 39 / / 34 / / 39 / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / / 1/ / 3/ / 1/ / 1/ / 3/ / 1/ / 3/ / 3/ / 5/ / 3/ / 1/ / 5/ / 1/ / 5/8 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER ITHOUT PRIOR NOTICE. 3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELO : a) COOLING - 27 C DB / 19 C B INDOOR AND 35 C DB / 24 C B OUTDOOR b) HEATING - 20 C DB INDOOR AND 7 C DB / 6 C B OUTDOOR 4) ARE ACCORDING TO JIS B 8616 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1.5m BELO THE CENTER OF THE UNIT. TESTED ITH 2m DUCT LENGTH AT THE AIR DISCHARGE OUTLET AND 1m DUCT LENGTH AT THE AIR RETURN INLET. S6
10 MULTI-SPLIT A4MSD-A SERIES ITH ALL MOUNTED - R407C HEATPUMP MODEL NOMINAL HEATING CAPACITY 50HZ 50 HZ NOMINAL POER INPUT- COOLING NOMINAL POER INPUT- HEATING NOMINAL TOTAL INPUT POER POER SOURCE AIR FLO UNIT EIGHT AM 10GR AM 15GR Btu/h 2 x x Btu/h 2 x x ONE UNIT RUNNING TO UNITS RUNNING ONE UNIT RUNNING TO UNITS RUNNING (H/M/L) AM 10G AM 15G Btu/h 2 x x ONE UNIT RUNNING TO UNITS RUNNING LO l/s / cfm / / / 345 l/s / cfm / / / 285 l/s / cfm / / / / 34 / / 34 / / 36 / 29 A4MSD1010AR 2 x AM 10GR A4MSD1015AR 260 / / / / / 25.4 UNIT EIGHT 840 / / / / / / GAS 2 x 9.52 / 2 x 3/ / 3/ / 1/ A4MSD1010A 2 x AM 10G 260 / / / A4MSD1015A A4MSD1515AR 2 x AM 15GR 2 x x x x A4MSD1515A 2 x AM 15G 2 x x / / / / 36 / / / / / / / / x 12.7 / 2 x 1/2 MULTI-SPLIT A4MST-A SERIES ITH ALL MOUNTED - R407C HEATPUMP MODEL NOMINAL HEATING CAPACITY 50 Hz NOMINAL TOTAL INPUT POER A4MST101010AR A4MST101015AR A4MST101515AR A4MST151515AR 3 x AM 10GR 2 x AM 10GR AM 15GR AM 10GR 2 x AM 15GR 3 x AM 15GR Btu/h 3 x x x x x x x x 3520 Btu/h 3 x x x x x x x x 3220 COOLING HEATING A4MST101010A A4MST101015A A4MST101515A A4MST151515A 3 x AM 10G 2 x AM 10G AM 15G AM 10G 2 x AM 15G 3 x AM 15G Btu/h 3 x x x x x x x x Hz NOMINAL TOTAL INPUT POER POER SOURCE AIR FLO LO (H/M/L) l/s / cfm / / / / / / 345 l/s / cfm / / / / / / 285 l/s / cfm / / / / / / / 34 / / 34 / / 36 / / 34 / / 36 / / 36 / / / / / / / / / / / / / 7.8 UNIT EIGHT / / / / / / / / / / / / 17.2 UNIT EIGHT 97 / / / / x 6.35 / 3 x 1/4 3 x 6.35 / 3 x 1/4 3 x 6.35 / 3 x 1/4 3 x 6.35 / 3 x 1/4 GAS 3 x 9.52 / 3 x 3/8 2 x 9.52 / 2 x 3/ / 1/ / 3/8 2 x 12.7 / 2 x 1/2 3 x 12.7 / 3 x 1/2 1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER ITHOUT PRIOR NOTICE. 3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELO : a) COOLING - 27 C DB / 19 C B INDOOR AND 35 C DB / 24 C B OUTDOOR b) HEATING - 20 C DB INDOOR AND 7 C DB / 6 C B OUTDOOR 4) ARE ACCORDING TO JIS C 9612 STANDARD. POSITION OF THE MEASUREMENT POINT IS 1m IN FRONT AND 0.8m BELO THE UNIT. S7
11 2007 Acson International AP - AMS
Aesthetically Attractive Indoor unit. Enhanced with various Indoor Air Quality Features. Negative Ion Generator (Standard)
MULTI SPLIT SYSTEMS Space Saving Only 1 outdoor is needed to couple with 2 or more indoors. Thus, this has effectively improved the floor space utilisation. The Multi-Split models are especially popular
More informationMulti Split Systems AP - MMS - 06A
Multi Split Systems P - MMS - 06 Space Saving Only 1 outdoor is needed to couple with 2 or more indoors. Thus, this has effectively improved the floor space utilisation. The Multi- Split models are especially
More informationInverter Series [ INVERTER ] All Product Brochure
Inverter Series [ INVERTER ] All Product Brochure About Acson International ith products available in more than 55 countries spread across 7 continents around the world, Acson is truly international. Backed
More informationCEILING CONCEALED SPLIT SYSTEM C SERIES
CEILING CONCEALED SPLIT SYSTEM C SERIES Microprocessor Controlled ith the microprocessor controlling the operation, the ACC model can offer comfortable room conditions according to the needs of the user.
More informationAll Product Catalogue
All Product Catalogue AP-MIY-12 Products manufactured in an ISO certified facility. This document contains the most current product information as of this printing. For the most up-to-date product information,
More informationResidential range. When technology meets comfort
Residential range When technology meets comfort Index Inverter technology 4 Indoor air quality 6 Design and control 8 Matching tables 10 Super Daiseikai 11 Suzumi 12 GKHP Fixed speed indoor units 13 Multi-split
More informationHitachi Multizone Heat Pump Air Conditioning
Cooling 1.5 13.2 Heating 1.5 14.4 Hitachi Heat Pump Air Conditioning Giving you complete control Zone control that s fast, efficient and clean Imagine being able to rapidly adjust the comfort levels in
More informationHELV NEUE BD CN 90% 51pts
HELV NEUE BD CN 90% 51pts CONTURA FG HIGH-WALL Mini-split Air Conditioners High-Wall Series 9,000-28,000 Btu/h (New) MCW and MWW Series 50/60Hz R22/R410A CONTURA FG HIGH-WALL New Look, New Experience TRANE
More informationMSP Duct S Specifications
MSP Duct S Specifications Model Name AM022FNMDEH AM028FNMDEH AM036HNMPKH AM045HNMPKH AM056HNMPKH Capacity *2) 2.2 2.8 3.6 4.5 5.6 *3) 2.5 3.2 4.0 5.0 6.3 Perfomance (Total) *5) kw 1.8 2.3 2.9 3.7 4.6 VRF
More informationAIR HANDLING UNITS YSE
IR DIG UITS YSE YSE Series ir andling Units YORK YSE Series ir andling Units are designed to provide a comfortable environment for factories, warehouses, office and stores etc. The coils can be used to
More informationCeiling Concealed Series FDMRN-AV1K. 50Hz. Preliminary
Ceiling Concealed Series FDMRN-AV1K 50Hz Nomenclature Main Benefits Engineering and Physical Data Electrical Data Capacity Tables Outline and Dimensions Electrical Connection Refrigerant Piping Nomenclature
More informationR410A TECHNICAL MANUAL. Inverter Single Split Series Air Conditioner. FTK-J, FTXN-J Series. Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2
R410A TECHNICAL MANUAL Inverter Single Split Series Air Conditioner FTK-J, FTXN-J Series Cooling only & Heatpump [50Hz] TM-5WMY-J-ST-A2 Table of Contents Table of Contents Nomenclature...1 Indoor...1 Outdoor...1
More informationR22 TECHNICAL MANUAL. Split Unit Air Conditioner Ceiling Cassette C & E Series FF-C, FHC-E, FFY-C, FHYC-E. Cooling only & Heatpump [50Hz]
R22 TECHNICAL MANUAL Split Unit Air Conditioner Ceiling Cassette C & E Series FF-C, FHC-E, FFY-C, FHYC-E Cooling only & Heatpump [50Hz] Table of Contents Table of Contents Nomenclature...1 Indoor...1
More informationConcealed Ducted Split Series R22
Concealed Ducted Split Series R22 24-60 MBH Ducted Split with Hermetic Compressor Tropical 50 Hz For more technical information please visit Table of Contents INTRODUCTION 2 NOMENCLATURE 2 UNIT RATING
More informationDC INVERTER DUCTED AIR CONDITIONERS
DC INVERTER DUCTED AIR CONDITIONERS DC Inverter Ducted Air Conditioners Technology. With over 5% of revenue invested in research and development programs, Hitachi has developed world leading technologies
More information50 Hz AIR - COOLED SPLIT SYSTEM. Products That Perform...By People Who Care AIR CONDITIONERS WITH SCROLL COMPRESSORS
R FORM NO: MS0305F Products That Perform...By People Who Care AIR - COOLED SPLIT SYSTEM AIR CONDITIONERS WITH SCROLL COMPRESSORS 50 Hz COOLING CAPACITY- 60 MBH TO 1360 MBH ACCS SERIES HEB-D, EB-D SERIES
More informationSplit. Air Conditioning Technical Data FTXC-A > FTXC25AV1B > FTXC35AV1B > FTXC50AV1B > FTXC60AV1B
Split Air Conditioning Technical Data FTXC-A > FTXC25AV1B > FTXC35AV1B > FTXC50AV1B > FTXC60AV1B Indoor Unit FTXC-A TABLE OF CONTENTS FTXC-A 1 Features.............................................................
More informationIndoor Console. Slim Design This is only 199mm thick, the slimmest on the market. Its slim design easily integrates the unit into your décor.
Indoor Console Slim Design This is only 199mm thick, the slimmest on the market. Its slim design easily integrates the unit into your décor. Black Display Functional art, the touch screen display is elegant
More informationFDYMP-D, FDP-D, FGP-D, FDYP-E, FGYP-E
R407C TECHNICAL MANUAL Split Systems Air Conditioner Ducted Blower D & E Series FDMP-D, FDYMP-D, FDP-D, FGP-D, FDYP-E, FGYP-E series Cooling only & Heatpump [50Hz] Table of Contents Table of Contents
More informationFFQN-C, FCRN-E, FFRN-C
R410A TECHNICAL MANUAL Split Unit Air Conditioner Ceiling Cassette C & E Series FCQN-E, FFQN-C, FCRN-E, FFRN-C Cooling only & Heatpump [50Hz] DAIKIN_FFRN.indb i 12/27/2012 9:28:06 AM DAIKIN_FFRN.indb ii
More informationFan Coil Unit Product Catalogue
AP-FCU-1 Chilled ater PRODUCT SYSTM all Mounted Cassette Ducted Fan Coil Unit Product Catalogue Products manufactured in an ISO certified facility. This document contains the most current product information
More informationLG Multi Split Air Conditioners
AUS-MUF111 New South Wales / Head Office 2 Wonderland Drive EASTERN CREEK NSW 266 PH : 02-8805-4000 FAX : 02-8805- Queensland 23 Terrace Place MURARRIE QLD 4 PH : 0-8-000 FAX : 0--41 Victoria 3 John Deere
More informationVRF. Technical Data Book. Ceiling for America (R410A, 60Hz, HP) Model : AM***FNCDCH***
VRF Technical Data Book Ceiling for America (R410A, 60Hz, HP) Model : AM***FNCDCH*** History Version Modification Date Remark Ver.1.0 Release Ceiling for America (R410A, 60Hz, HP) 15.11.04 - 1 Nomenclature
More informationV33B High Efficiency 360 Cassette Indoor Models - 60HZ
PRODUCT SPECIFICATIONS Low-sound, high efficiency cassette, encased in galvanized steel offers 360 airflow for immediate, equal distribution of wide-range cooling and heating. Cassette has motor-driven
More informationStylus 4G. Mini Split Air Conditioners. Stylus 4G Series Convertible Type 12,000-60,000 Btu/h MCX / MWX SERIES 50 Hz R22 / R410a
Stylus 4G Mini Split Air Conditioners Stylus 4G Series Convertible Type 12,000-60,000 Btu/h MCX / MWX SERIES 50 Hz R22 / R410a Stylus 4G Comfort Solutions Trane proudly presents the Stylus 4G air conditioners
More informationDuctless Split Systems
Ductless Split s Right Product for the Right Application Ductless Split s Right Product for the Right Application 1:1 2:1 to 5:1 High Wall High Wall, Cassette, Underceiling 2:1 to 5:1 High Wall Up to 23.0
More informationChiller, Close control and Water terminals. Air Conditioning. Light Commercial, Commercial and Industrial
Chiller, Close control and Water terminals Air Conditioning Light Commercial, Commercial and Industrial Water Terminals 133 Water Terminals Fan coils & Cassette Centrifugal fan-coil SYSCOIL Ductable fan-coil
More informationTECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS
Version.MDT-2016.T3.103 TECHNICAL GUIDE R410a SPLIT SYSTEM 1.5 to 5.0 NOMINAL TONS FEATURES AND BENEFITS COMPRESSOR: Compressors are protected with internal temperature and current overloads. An internal
More informationDuctless Split Systems
Ductless Split s Right Product for the Right Application September 2014 Ductless Split s Right Product for the Right Application Single-Zone s Multi-Zone s (up to five rooms) High Wall High Wall, Cassette,
More informationDuctless Split Systems
Ductless Split s Right Product for the Right Application Ductless Split s Right Product for the Right Application 1:1 2:1 to 5:1 9-24K High Walls 18-24/6/42/60K High Walls, Cassette, Underceiling 2:1 to
More informationVHIA High-Static Ducted Indoor Units - 60HZ
PRODUCT SPECIFICATIONS Compact design for limited space requirements. Installs out of sight between the drop ceiling and ceiling slab with ducted distribution to the indoor space. All models have three-stage
More informationProduct Catalog. Variable Refrigerant Flow (VRF) VRF-PRC026A-EN. Mid-Static Concealed (Ducted) Indoor Units. November 2015
Product Catalog Variable Refrigerant Flow (VRF) Mid-Static Concealed (Ducted) Indoor Units Indoor Unit Model number: 4TVD****C***** November 2015 VRF-PRC026A-EN Introduction Trane variable refrigerant
More informationMODEL FF50 CEILING FAN
MODEL FF50 CEILING FAN SPECIFICATION SHEET Simple installation dependability make this odor moisture removing fan a real value. Matte white polymeric blends well with any decor Torsion spring grill mounting
More informationINVERTER DUCTED SYSTEMS
INVERTER DUCTED SYSTEMS What you ll find inside: DC Twin-Rotary Compressor Inverter Ducted advantages Controllers Product specifications Energy Efficient Powerful Operation Flexible Application 1 About
More informationSINGLE. Technical Data Book. 4Way Cassette S for Nordic (R410A, 50Hz) Model : AC***JN4CEH/EU (ODU: AC***JXSC*H/EU)
SINGLE Technical Data Book 4Way Cassette S for Nordic (R4A, 5Hz) Model : AC***JN4CEH/EU (ODU: AC***JXSC*H/EU) History Version Modification Date Remark Ver.1. Released SINGLE for Nordic TDB 15.3.. Ver.1.1
More informationYCZ HIGH WALL RESIDENTIAL MULTISPLIT DUO/TRIO/QUATTRO/CINCO
YCZ RESIDENTIAL MULTISPLIT DUO/TRIO/QUATTRO/CINCO q Multi line available in four capacities from 5.2 up to 10.5 kw. q DC Inverter and sine wave compressor drive technology. q Match with high wall, ducted,
More informationBosch BOVA Split System Heat Pump
Bosch BOVA Split System Heat Pump Condensing Units Up to 18 SEER 2-3-4-5 Ton Capacity R410A Product Specifications 2 Bosch IDS BOVA Product Specifications Data subject to change 06.2016 Bosch Thermotechnology
More informationBosch BOVA Split System Heat Pump
Bosch BOVA Split System Heat Pump Condensing Units Up to 18 SEER 2-3-4-5 Ton Capacity R410A Product Specifications 2 Bosch IDS BOVA Product Specifications Data subject to change 03.2018 Bosch Thermotechnology
More informationPREMIUM INVERTER DUCTED AIR CONDITIONING
PREMIUM INVERTER DUCTED AIR CONDITIONING PANASONIC LEADS THE WAY Ducted Air Conditioning Specialists With more than 30 years of experience, exporting to more than 120 countries around the world, Panasonic
More informationIt is a kind of fan coil unit that is connected to the chillers to realize cooling/heating for civil or residential use.
Concealed Ceiling It is a kind of fan coil unit that is connected to the chillers to realize cooling/heating for civil or residential use. Inner groove copper ashable filter Quiet function Multi fan speed
More information40KQV. Direct expansion split system Inverter Cassette. Nominal Cooling capacity: 4,85-12,40 kw Nominal Heating capacity: 5,10-13,00 kw
LLOYD'S REGISTER QUALITY ASSURANCE Direct expansion split system Inverter Cassette I S O 9 00 1 40KQV Nominal Cooling capacity: 4,85-12,40 kw Nominal Heating capacity: 5,10-13,00 kw 40KQV cassette belongs
More informationV33A Standard/High Efficiency 360 Cassette Indoor Models - 60HZ
PRODUCT SPECIFICATIONS Low-sound, standard or high efficiency cassette, encased in galvanized steel offers 360 airflow for immediate, equal distribution of wide-range cooling and heating. Cassette has
More informationSi Series Model CE Residential Geothermal Heat Pump
Si Series Model CE Engineering Submittal Sheet Overview and Certifications Standard Features, Factory Installed Options, and Field Installed Accessories Standard Features CE Model 025-071 5 Models: 025,
More informationAll Product Catalogue
All Product Catalogue AP-MIY-10 Products manufactured in an ISO certified facility. This document contains the most current product information as of this printing. For the most up-to-date product information,
More informationPH120. Rooftop Packaged. R410a Refrigerant PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C
PH120 R410a Refrigerant Rooftop Packaged INDOOR COIL ENTERING AIR TEMP 0 c DB WB 21 23 25 27 29 31 PERFORMANCE DATA OUTDOOR COIL ENTERING TEMPERATURE 0 C 30 35 40 45 Cap Cap Cap Cap 17 115.3 70.7 11.5
More informationRESIDENTIAL & LIGHT COMMERCIAL AIR CONDITIONERS 2015 / 2016 EVERY BUILDING MATTERS
RESIDENTIAL & LIGHT COMMERCIAL AIR CONDITIONERS 2015 / 2016 EVERY BUILDING MATTERS A Better Life, A Better World As we move towards our Centenary in 2018, our new brand slogan encapsulates Panasonic s
More informationtechnical sales guide - 60Hz Ducted Split Units HIGH AMBIENT OPERATION 52 UPTO
technical sales guide - 60Hz Taurus R Ducted Split Units UPTO HIGH AMBIENT OPERATION 52 O C Page CONTENTS Nomenclature.. 2 Description. 3 Features.. 3 Product Data. 4 Condensing Unit Cooling Performance
More informationPACKAGE UNIT PCA340U TECHNICAL SELECTION DATA. -10 o C UNIT FEATURES SPECIFICATION SUMMARY UNIT OPTIONS CONTROL OPTIONS UNIT COMPLIANCE.
TECHNICAL SELECTION DATA PACKAGE UNIT + o C -10 o C 3 THREE PHASE SCROLL TWO STAGE CENTRIFUGAL LOUVRE LIANT SCROLL RESSOR AXIAL UNIT FEATURES SPECIFICATION SUMMARY Scroll Compressor Multiple Speed Outdoor
More informationTechnical Service Manual. TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph
Technical Service Manual TVR LX Systems Medium Static Pressure Duct Units with DC Fan Motor 220-240V/50-60Hz/1ph August 20 Medium Static Pressure Duct Unit With DC Fan Motor 1. Features...2 2. Specifications...4
More informationCOMMERCIAL // HEATING AND COOLING SYSTEMS EVERY OFFICE MATTERS
2010 COMMERCIAL // HEATING AND COOLING SYSTEMS EVERY OFFICE MATTERS COMMERCIAL WELCOME TO COMMERCIAL RANGE Welcome to Commercial range. Welcome to healthier air. A range which confi rms its commitment
More informationPerformance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW
R410a Refrigerant SHS1 Split Ducted Model INDOOR COIL ENTERING AIR TEMP DB WB 21 23 2 27 29 31 Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE 30 3 40 4 17 14.0 9.1 9.8 13.2 8.8 9.0 12. 8. 12.9
More informationSuperior Performance in Extreme Temperature Submittal Data: SAP09HP230V1A
Superior Performance in Extreme Temperature Submittal Data: 9,000 BTU/H Wall Mounted Heat- Pump System Job Name Location Date Purchaser Engineer Submitted To For Unit Designation Schedule No. GENERAL FEATURES
More informationCool with the sun and save 60% of your power
Cool with the sun and save 60% of your power Saves up to 60% of your electrical power Same prices as non solar systems (incl. panel!) Top technology with attractive indoor units Heat pump for cooling and
More informationVWMB Wall-Mounted Non-Ducted Indoor Models - 60HZ
PRODUCT SPECIFICATIONS VARIABLE REFRIGERANT FLOW SYSTEMS VRF VWMB Wall-Mounted Non-Ducted Indoor Models - 60HZ Bulletin No. 210712 March 2018 Low-sound, three-speed Wall Mount with LED display offers three
More informationMultizone Multi Split systems
19 Multizone Multi Split systems Features and Benefits 2 Room 3 Room 4 Room 5 Room 6 Room RAM-36NP2A RAM-53NP2A RAM-53NP3A RAM-68NP3A RAM-70NP4A RAM-90NP5A RAM-130NP6A Nominal Cooling Capacity (kw) 3.6
More informationProduct Data. FS3QX Slim Line Ducted Fan Coil With Plenum Sizes 018 thru 060 SLIM LINE DUCTED FAN COIL WITH PLENUM ON/OFF DISPLAY TEMP
FS3QX Slim Line Ducted Fan Coil With Plenum Sizes 018 thru 060 Product Data A114 SLIM LINE DUCTED FAN COIL WITH PLENUM Installation Ease S Factory installed 24 volt transformer and relay S High and low
More informationBAC / BHC Product Specifications
COMMERCIAL AIR HANDLERS (3 PHASE) 6 to 20 TON / Product Specifications REFRIGERATION CIRCUIT Standard factory-installed thermostatic expansion valves (TXVs) on units; units include TXVs and check valves
More informationLow Static Pressure Duct(V shape evaporator)
Low Static Pressure Duct (V shape evaporator) 1. Features... 116 2. Specifications... 118 3. Dimensions... 121 4. Service Spaces... 123 5. Piping Diagrams... 124 7.Fan Performance... 126 8.Capacity Tables...
More informationGCL Technical Manual. Split System Air Conditioner GCL TAC 640. Electronic Control. Air Conditioners
GCL 513-2651-5 Technical Manual Split System Air Conditioner GCL 3-55 TAC 64 Electronic Control Air Conditioners Contents A. Preface... 1-2 TRODUCTION... 1-2 1. GALAXY LE GENERAL DESCRIPTION... 1-3 1.1
More informationVMDA Concealed Medium Static Ducted Indoor Models - 60HZ
VARIABLE REFRIGERANT FLOW SYSTEMS VRF VMDA Concealed Medium Static Ducted Indoor Models - 60HZ PRODUCT ECIFICATIONS Slim, compact design for limited space requirements. Installs out of sight between the
More informationGPC14H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER
Cooling Capacity: 24,000-57,500 BTU/H H 2- to 5-Ton Packaged Air Conditioner Up to 14 SEER Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 5 Airflow Data... 18 Heater Kit
More informationHi-Wall Inverter Split System. Efficient, effective and comfortable cooling and heating where you need it
Hi-Wall Inverter Split System Efficient, effective and comfortable cooling and heating where you need it The Convenient Solution Feature Packed The Brivis Hi-Wall Inverter Split System has a pleasing,
More informationManufacturer reserves the right to change these specifications at any time without incurring obligation. Btuh (kw) SEER SHR EER
UNHA-T2CA-T3CA-T4CA Universal Air Handler Multi-Zone Only Rev. 1.0 [07/07] JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE: UNIT
More informationGPC14H. 2- to 5-Ton Packaged Air Conditioner 14 SEER. Cooling Capacity: 24,000-57,500 BTU/H
H Cooling Capacity: 24,000-57,500 BTU/H 2- to 5-Ton Packaged Air Conditioner 14 SEER Contents Nomenclature... 2 Product Specifications... 3 Expanded Cooling Data... 4 Airflow Data... 16 Heater Kit Specifications...
More informationPRK PREVIEW. System. OZONE FRIENDLY R-407C Series. Inverter Heat Pump Series Heat Recovery Series PLUS Series (Heat Pump)
PRK 00-04 PREVIEW System OZONE FRIENDLY R-407C Series Inverter Heat Pump Series Heat Recovery Series PLUS Series (Heat Pump) 3DUW#4 2XWGRRU#8QLWV 111111111111111111111111111111111111111111111111111111111111111111111
More informationVersion Modification Date Remark
Version Modification Date Remark Products 1 Nomenclature... 2 Line-up... 3 Accessory... 1 Nomenclature 1-1. Nomenclature Model name AM RVX 45 1 HF TN T4 FD EE EH / EU 1 (Buyer) Classification AM DVM
More informationVMDB Concealed Medium Static Ducted Indoor Models - 60HZ
VARIABLE REFRIGERANT FLOW SYSTEMS VRF VMDB Concealed Medium Static Ducted Indoor Models - 60HZ PRODUCT ECIFICATIONS Bulletin No. 210711 March 2018 Slim, compact design for limited space requirements. Installs
More informationUnique solutions FLEXY MATCH FLEXY MATCH FLEXY MATCH R410A FLUID AUTO AUTO CLEAN/DRY SLEEP MODE LOW BATTERY INDICATION WIRED CONTROL OPTION
2013 Catalogue Monosplit DCI HJD Unique solutions FLEXY MATCH ADVANCED CONTROL OPTIONS HIGH WALL MONO & PREMIUM MULTI FLEXY MATCH STERIONIZER q High wall line available in capacities 2.5 up to 7.5 kw.
More informationHi-Wall Inverter Split System. Cooling and heating, exactly where and when you need it
Hi-Wall Inverter Split System Cooling and heating, exactly where and when you need it Save on Running Costs 2.6kW & 3.2kW 4.2kW & 5.0kW 7.0kW & 8.0kW High Efficiency Along with running cost savings due
More informationRooftop Packaged Air Conditioners
Catalog Rooftop Packaged Air Conditioners Models: MRT 055 A/AR MRT 060 A/AR MRT 080 A/AR MRT 100 A/AR MRT 120 A/AR MRT 150 A/AR MRT 200 A/AR MRT 250 A/AR MRT 300 A/AR MRT 360 A/AR MRT 420 A/AR M4RT M4RT
More informationHBC SERIES-PSC MOTOR HBCX SERIES-ECM MOTOR
PRODUCT SPECIFICATIONS *HBC(X) *PHBC(X) *RHBC(X) *CHBC(X) Chilled Water/Hot Water 2-pipe/4-Pipe HBC SERIES- HBCX SERIES-ECM MOTOR Ceiling Concealed Horizontal -1 CFM Ceiling Concealed Ceiling Recessed
More informationET4BE Series R-410A High Efficiency Heat Pump 14 SEER Residential System 1 1/2 5 Ton Capacity
TECHNICAL SPECIFICATIONS ET4BE Series R-410A High Efficiency Heat Pump 14 SEER Residential System 1 1/2 5 Ton Capacity ET4BE Series now offers the choice of a heat pump that uses a more efficient and environmentally
More informationTechnical Service Manual. TVR LX Systems Low Static Pressure Duct Units with DC Fan Motor V/50-60Hz/1ph
Technical Service Manual TVR LX Systems Low Static Pressure Duct Units with DC Fan Motor 220-240V/50-60Hz/1ph August 2015 1. Features...2 2. Specifications...3 3. Dimensions...7 4.Service Spaces...8 5.Piping
More informationJT4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 14 SEER Residential System Ton Capacity WARRANTY
TECHNICAL SPECIFICATIONS JT4BE Series R-410A High Efficiency Heat Pump 14 SEER Residential System 1.5 5 Ton Capacity The JT4BE Series now offers the choice of a heat pump that uses a more efficient and
More informationAmendment Sheet. Code : ADB-FR Date : Superceded : nil REFRIGERANT CIRCUIT DIAGRAM
mendment Sheet Code : DB-FR-007-0001 Date : 18-0-008 Superceded : nil REFRIGERNT CIRCUIT DIGRM GENERL DT HETPUMP (R) NOMINL COOLING CPCITY NOMINL HETING CPCITY NOMINL TOTL INPUT POER (COOLING) NOMINL TOTL
More informationDuctless Systems. Right product for the right application. Fall 2015 Edition
Ductless Systems Right product for the right application Fall 2015 Edition Right Product for the Right Application Single Zone - Residential Single Zone - Light Commercial Multi-Zone RAV-**KRT System High
More informationAFFORDABLE DUCTLESS SOLUTIONS FROM AMERISTAR
AFFORDABLE DUCTLESS SOLUTIONS FROM AMERISTAR Cost-effective solutions for single-zone and multi-zone ductless applications Whether providing options for single-zone or multi-zone applications, these units
More informationDUCTED AIR CONDITIONING YEAR ROUND COMFORT FOR YOUR HOME
DUCTED AIR CONDITIONING YEAR ROUND COMFORT FOR YOUR HOME PANASONIC LEADS THE WAY Ducted Air Conditioning Specialists With more than 30 years of experience, exporting to more than 120 countries around the
More informationVRF. Technical Data Book. Duct S for Europe (R410, 50Hz)
VRF Technical Data Book Duct S for Europe (R410, 50Hz) Version Modification Date Remark Ver.1.0 Release VRF DVM S IDU Duct S for Europe (R410A, 50Hz) TDB 14.09.22 Ver.1.1 External Pressure Minimum data
More informationLG MULTI SPLIT SYSTEM
50Hz LG MULTI SPLIT SYSTEM Unlike traditional multitype units, it is a nextgeneration multitype airconditioner designed to be installed under any circumstance. LG Multi Split System Why? LG Multi World
More informationBAC / BHC SERIES 6 to 20 Ton Air Handlers
/ SERIES 6 to 20 Ton Air Handlers COMMERCIAL SPLIT SYSTEM AIR HANDLER FEATURES CONSTRUCTION Die-formed galvanizedsteel casingsprovide durabilityand structuralintegrity. HIGH STATIC DESIGN High static design
More informationVT4BE Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 14 SEER Residential System Ton Capacity WARRANTY
TECHNICAL SPECIFICATIONS VT4BE Series R-410A High Efficiency Heat Pump 14 SEER Residential System 1.5 5 Ton Capacity The VT4BE Series now offers the choice of a heat pump that uses a more efficient and
More informationBAC / BHC SERIES 6 to 20 Ton Air Handlers
/ SERIES 6 to 20 Ton Air Handlers COMMERCIAL SPLIT SYSTEM AIR HANDLER FEATURES CONSTRUCTION Die-formed galvanizedsteel casingsprovide durabilityand structuralintegrity. HIGH STATIC DESIGN High static design
More informationHitachi Inverter Wall Split Air Conditioning
Cooling Capacity 2.5kW - 8.0kW Heating Capacity 3.2kW - 9.0kW Hitachi Air Conditioning Giving you complete control Water-cooled Units Hitachi and Temperzone: Combining to offer Australia and New Zealand
More informationEngineering Data Book
40VMH High Static Duct Indoor Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without
More informationtechnical data air conditioning systems Round Flow Cassette FXFQ-P9VEB
technical data Round Flow Cassette FXFQ-P9VEB air conditioning systems technical data Round Flow Cassette FXFQ-P9VEB air conditioning systems TABLE OF CONTENTS FXFQ-P9VEB 1 Specifications.......................................................
More informationCAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE
COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 20 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE Single stage cooling capacity control on all 0 241 models Two stage cooling capacity control on
More informationMODEL FF/FFC CEILING AND INLINE/CABINET VENTILATORS
MODEL FF/FFC CEILING AND INLINE/CABINET VENTILATORS APPLICATION The extremely quiet FF and FFC ventilators are used to exhaust air from a variety of commercial and institutional applications, such as restrooms,
More informationSplit-Sky Air FDYP-B7 Concealed Ceiling Unit
TECHNICAL DATA Split-Sky Air FDYP-B7 Concealed Ceiling Unit Split Sky Air ISO14001 assures an effective environmental management system in order to help protect human health and the environment from the
More informationPerformance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW
R410a Refrigerant SHS25 Split Ducted Model INDOOR COIL ENTERING AIR TEMP DB WB 21 2 25 27 29 1 Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE 0 5 40 45 17 2.4 1.8 11. 22.2 1.4 11.9 21.1 12.9 12.2
More informationMVAM2241T MVAM2801T MVAM3351T MVAM4001T MVAM4501T MVAM5041T MVAM5601T MVAM6151T. 2-pipe system Golden Fin 3-pipe system MVA_CS - MVA_C - MVA_CB
MV Multisplit reversible Heat Pumps Variable refrigerant flow system (VRF) ooling apacity from 12,1kW to 246kW Heating apacity from 14,0kW to 276kW For systems with 2 and 3 pipes OUTDOOR UNITS MVS MVM
More informationPerformance Data OUTDOOR COIL ENTERING AIR TEMPERATURE C 30 C 35 C 40 C 45 C LWB C. Sens Cap KW
R410a Refrigerant SHS35 Split Ducted Model INDOOR COIL ENTERING AIR TEMP DB WB 21 23 25 27 29 31 Performance Data OUTDOOR COIL ENTERING AIR TEMPERATURE 30 35 40 45 17 34.1 21.1 11.4 32.5 20.4 11.7 30.8
More informationJT4BD Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. R-410A High Efficiency Heat Pump 13 SEER Residential System Ton Capacity WARRANTY
TECHNICAL SPECIFICATIONS JT4BD Series R-410A High Efficiency Heat Pump 13 SEER Residential System 1.5 5 Ton Capacity The JT4BD Series now offers the choice of a heat pump that uses a more efficient and
More informationmodular multi intelligent, environmental and versatile
modular multi intelligent, environmental and versatile system overview 2-pipe R407C heat pump VRF system From 8 to 46 HP in one piping system (19 steps) Active leak detection system option Up to 40 indoor
More informationEngineering Data Book
40VMM Medium Static Duct Indoor Unit for Variable Refrigerant Flow (VRF) Systems Engineering Data Book Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without
More informationSSZ14 PRODUCT SPECIFICATIONS 14 SEER HIGH-EFFICIENCY, R-410A SPLIT SYSTEM HEAT PUMP 1½ TO 5 TON
HIGH-EFFICIENCY, R-410A SPLIT SYSTEM HEAT PUMP The Goodman uses the environmentally friendly refrigerant R-410A and features operating sound levels that are among the best in the heating and cooling industry.
More informationNow there s a sleek new profile in heat pumps
New RELEASE Now there s a sleek new profile in heat pumps The Mitsubishi Electric Designer Series has been awarded the if Product Design award for its simple and elegant design. The clean, flat surfaces
More informationair handling units YAH
air handling units YAH Air Handing Units YAH Series YORK YAH series ceiling-mounted air handling units are terminal points of central air-conditioning systems. They are designed for fresh air units or
More informationVT4BF-KA/B Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. Ultra High Efficiency Heat Pump 16 SEER Residential System 2-5 Ton Capacity
TECHNICAL SPECIFICATIONS VT4BF-KA/B Series Ultra High Efficiency Heat Pump 16 SEER Residential System 2-5 Ton The VT4BF-KA/B series now offers the choice of a heat pump that uses a more efficient and environmentally
More informationPA95 12 SEER FEATURES 2 THRU 4 TON SINGLE PACKAGE
PACKAGE AIR CONDITIONER PA95 12 SEER C 2 THRU 4 TON SINGLE PACKAGE FEATURES CONSTRUCTED FOR DURABILITY All panels made from galvanized steel pre--coated inside and out -- using a polyester top coat, on
More information