Safety switches for hinged doors

Similar documents
Safety switches for hinged doors

Position switches FC series

Position switches FD series

Position switches FR series

Safety switches for hinges

Position switches FR series

Safety rope switch with reset for emergency stop

Safety rope switches with reset for emergency stop

FL series position switches

Safety switches with separate actuator

Safety rope switch without reset for simple stop

Safety switches with separate actuator

Single foot switches PX and PA series

Rope safety switches with reset for emergency stop

Switches with manual reset

Prewired position switches FF series

Microswitches M series

Safety switches with solenoid and separate actuator

Prewired position switches FF series

LK Position Switches TECHNICAL DATASHEET.

Safety switches with solenoid and separate actuator

Single foot switches PX and PA series

LR-LX-LK-LW Safety Switches with separate actuator

Microswitches MK series

SFS-UFS Single Foot Switches

Microswitches MK series

Microswitches MK Series

Switches in conformity with ATEX directive

Switches in conformity with ATEX directive

Safety switches with solenoid and separate actuator

Single foot switches - PX and PA series

Safety switches with solenoid and separate actuator

Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66

Safety Limit Switches

Safety switches with solenoid and separate actuator

Limit Switches - Safety Type Plastic Body IP65 and Metal Body IP66

Safety switches with solenoid and separate actuator

Limit Switches - Limit Type (PS21L) Metal Body IP66

Miniaturized limit switches

Limit Switches - Limit Type Plastic Body IP65

Pre wired limit switches

Limit Switch - Prewired Type Metal Body

Limit Switches - Limit Type Plastic Body IP65

F E - Electromagnetic Safety Switch With Separated Actuator. 1 Code Construction. Casing: P: Plastic casing

Limit switches. 7 Page 71. Presentation. OsiSense XC Basic Compact design, plastic, with reset knob, types XCNR and XCNTR. b XCNR.

Limit Switches - Limit Type (PS31L) Plastic Body IP65

Selection diagram. Actuators. Body. Contact blocks. Cable entry A A S1 B B 13. Thermoplastic

Limit Switches - Limit Type (PS42L) Plastic Body IP65

Double insulated, types XCK-P and XCK-T. With head for linear movement (plunger) operators

Comepi S.r.l. reserves the right to modify its products and to change any details in this pubblication at any time without prior notice.

AF40... AF96 3-pole contactors Technical data

Limit switches 3. Page 92. Page 92

Safety Limit Switch

D4B- N. Safety Interlock Switches. Safety Limit Switch. Specifications. Standards and EC Directives. Certified Standard Ratings D4BN

Selection diagram. Actuators. Bodies. Contact blocks. Cable entry AB BB CB. Thermoplastic

Selection diagram. Actuators. Body. Contact blocks. Cable entry A A S1 B B 13. Thermoplastic

Automation - Lift - Handling System - Atex

PRODUCT SPECIFICATION. Foot Switches. Series.

XCKJ390559H29EX limit switch XCKJ - round rod Ø 6 mm - 2NC + NO - ATEX/IECEx

LS Series Limit Switches. Short Form Catalogue AC1300 ABB

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

Limit switches. Presentation. OsiSense XC Special For hoisting and material handling applications, type XCR. b XCR

Recommended use With its standard enclosure, the ENM2 limit switch can be used universally in all industrial and safety applications.

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

Metal limit switches are made of zinc alloy and have a degree of protection of IP67 and NEMA Type 4, 4X.

Limit switches. 6 Thermoplastic roller lever 1 direction of actuation SEN TRONIC AG. Presentation

Safety switches with solenoid and separate actuator

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

Installation and Operating Instructions

SG-B1 SERIES / SG-A1 SERIES

Selection diagram. Actuators. Body. Contact blocks. Cable entry A A S1 B B 13. Thermoplastic

XACA871 pendant control station XAC-A - 8 pushbuttons

HS5D Miniature Interlock Switches

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

Pendant control stations 6

YFC. Limit switch. Ex d. 24 operating head types

Standard Interlock Safety Switches

Operation Key D4BS - K Head Mounting Direction F: Four mounting directions possible (front-side mounting at shipping)

Solenoid interlocks AZM 170 range. 98 Schmersal 22 8,2 60. ø4,2. ø Pg 11

Compact plastic limit switches with positive opening mechanism

FOOT SWITCHES

XCKP2145P16 limit switch XCKP - th.plastic roller lever var.length - 1NC+1NO - snap - M16

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

Technical data. Standards: IEC/EN BG-GS-ET-15

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

Hinged Safety Door Switch

Manual Reset Limit Switch

Compact plastic limit switches with positive opening mechanism

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

Limit Switch D4D- N. Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660

S840, S845, S846 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D40.en

XACA871 pendant control station XAC-A - 8 pushbuttons

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.

NH DIN Dual Indication Fuse Links

Solenoid interlocks AZM 190 range. 128 Schmersal ,3 4,5 M20 17,5 23,5

Industrial Contactors CTX 3 3P 185A - 800A

Technical data. Standards: IEC/EN ; EN ISO ; EN 1088; BG-GS-ET-19

Position Switches Series 8074/2

Transcription:

4C Safety switches for hinged doors Selection diagram CONTACT BLOCKS 18 7 9 20 overlapped 1NO+ FD FL FC 21 22 33 34 2NO+1NC 3NC CONDUIT ENTRIES Threaded conduit entries (standard) With cable gland assembled With M12 metal connector assembled and wired page 4/37

Code structure Attention! The feasibility of a code number does not mean the effective availability of a product. Please contact our sales office. 1 Housing FD metal housing, one conduit entry FL metal housing, three conduit entries Contact blocks 18, 7, overlapped 9, 20 1NO+, 21 3NC, 22 2NO+1NC, 33, 34, article FD 189-GM2K0 Contacts type silver contacts (standard) G silver contacts gold plated 1 µm options Preinstalled cable gland or connectors no cable gland or connector (standard) K21 with assembled cable gland suitable for Ø to Ø 12 mm cables range...... K0 with poles M12 metal connector...... For the complete list of all combinations, please contact our technical office. Threaded conduit entry PG 13, (standard) M2 M20x1, 1A 1B 2 2A 2B 2C 2D 2E 3 3A 3B Housing FC metal housing, one conduit entry Contact blocks 33, 34, article options FC 339-M1K22 Preinstalled cable gland no cable gland (standard) K22 K2 Threaded conduit entry PG 11 (standard) M1 M1x1, with assembled cable gland suitable for Ø to Ø 10 mm cables range with assembled cable gland suitable for Ø 3 to Ø 7 mm cables range 3C 4 4A 4B 4C 4D 4E 4F 4G 4H page 4/38

4C Safety switches for hinged doors Technical data Housing Housing type FD, FL and FC made of metal, coated with baked epoxy powder. Stainless steel actuator. FD, FC series one conduit entry FL series three conduit entries Protection degree: IP7 according to EN 029 Main data Metal housing, from one to three conduit entries Protection degree IP7 8 contact blocks available M12 assembled connector versions Silver contacts gold plated versions Markings and quality marks: Approval IMQ: EG0 (FD-FL-FC series) Approval UL: E131787 Approval CCC: 200701030230000 (FD-FL-FC series) Approval EZU: 101011 General data Safety parameters: see page /32 Ambient temperature: from -2 C to +80 C Version for operation in ambient temperature from -40 C to +80 C on request Max operating frequency: 300 operations cycles 1 /hour Mechanical endurance: 1 million of operations cycles 1 Max actuating speed: 180 /s Min. actuating speed: 2 /s Driving torque for installation: see pages /1-/10 (1) One operation cycle means two movements, one to close and one to open contacts, as foreseen by EN 0947- -1 standard.. Cross section of the conductors (flexible copper wire) Contact blocks 20, 21, 22, 33, 34: min. 1 x 0,34 mm 2 (1 x AWG 22) max. 2 x 1, mm 2 (2 x AWG 1) Contact blocks 7, 9, 18: min. 1 x 0, mm 2 (1 x AWG 20) max. 2 x 2, mm 2 (2 x AWG 14) In conformity with standards: IEC 0947--1, EN 0947--1, IEC 0204-1, EN 0204-1, EN 1088, EN ISO 12100-1, EN ISO 12100-2, IEC 029, EN 029, NFC 3-140, VDE 00-200, VDE 0113, CENELEC EN 0013. Approvals: IEC 0947--1, UL 08, GB14048.-2001 In conformity with requirements requested by: Low Voltage Directive 200/9/EC, Machinery Directive 200/42/EC and Electromagnetic Compatibility 2004/108/EC. Positive contact opening in conformity with standards: IEC 0947--1, EN 0947--1, VDE 00-20. If not expressly indicated in this chapter, for the right installation and the correct utilization of all articles see requirements indicated from page /1 to page /10. Electrical data Utilization categories without connector with poles M12 connector Thermal current (Ith): 10 A Rated insulation voltage (Ui): 00 Vac 00 Vdc 400 Vac 00 Vdc for contact blocks 20, 21, 22, 33, 34 Conditional shot circuit current: 1000 A according to EN 0947--1 Protection against short circuits: fuse 10 A 00 V type am Pollution degree: 3 Thermal current (Ith): 4 A Rated insulation voltage (Ui): 20 Vac 300 Vdc Protection against short circuits: fuse 4 A 00 V type gg Pollution degree: 3 Alternate current: AC1 (0...0 Hz) Ue (V) 20 400 00 Ie (A) 4 1 Direct current: DC13 Ue (V) 24 12 20 Ie (A) 1,1 0,4 Alternate current: AC1 (0...0 Hz) Ue (V) 24 120 20 Ie (A) 4 4 4 Direct current: DC13 Ue (V) 24 12 20 Ie (A) 4 1,1 0,4 with 8 poles M12 connector Thermal current (Ith): 2 A Rated insulation voltage (Ui): 30 Vac 3 Vdc Protection against short circuits: fuse 2 A 00 V type gg Pollution degree: 3 Alternate current: AC1 (0...0 Hz) Ue (V) 24 Ie (A) 2 Direct current: DC13 Ue (V) 24 Ie (A) 2 page 4/39

Description These safety switches have been designed to control gates or guards which protect against hazardous parts of the machines. They are very sensitive and positively open the contacts after few degrees of rotation, sending an immediate stop signal. The head may rotate in 90 steps, allowing its installation in a great variety of positions. The metal housing and the stainless steel actuator allow this switch to be used even in hard environments where sedimented powder or dirty could block working of safety switches with separated actuator. 1 1A 1B Rotating heads Installation examples Data type approved by IMQ, CCC and EZU Rated insulation voltage (Ui): 00 Vac 400 Vac for contact blocks 20, 21, 22, 33, 34 Thermal current (Ith): 10 A Protection against short circuits: fuse 10 A 00 V type am Protection degree: IP7 MV terminals (screw clamps) Pollution degree 3 Utilization category: AC1 Operation voltage (Ue): 400 Vac (0 Hz) Operation current (Ie): 3 A Forms of the contact element: Zb, Y+Y, Y+Y+X, Y+Y+Y, Y+X+X Positive opening of contacts on contact block 7, 9, 18, 20, 21, 22, 33, 34 In conformity with standards: EN0947-1, EN 0947--1 and subsequent modifications and completions, fundamental requirements of the Low Voltage Directive 200/9/CE and subsequent modifications and completions. Data type approved by UL Removing the four fastening screws, in all switches, it is possible to rotate the head in 90 steps. Utilization categories Q300 (9 VA, 12-20 Vdc) A00 (720 VA, 120-00 Vac) Data of the housing type 1, 4X indoor use only, 12, 13 For all contact blocks use 0 or 7 C copper (Cu) conductor and wire size No. 12-14 AWG. Terminal tightening torque of 7,1 lb in (0.8 Nm). In conformity with standard: UL 08 Please contact our technical service for the list of approved products. 2 2A 2B 2C 2D 2E 3 3A 3B 3C 4 4A 4B 4C 4D 4E 4F 4G 4H Please contact our technical service for the list of approved products. page 4/40

4C Safety switches for hinged doors Dimensional drawings Contacts type: L = LO = overlapped Contact blocks 18 L 104.3 0 2 12.8 FD 189. 30 40 0 metal housing metal housing metal housing.3 Ø14 Ø10 M4.3x7.3 9 3.2 78. 13 22 27.3 30 1 30 94.8 12.8 2 7 FL 189.2x.2 18 M4 Ø14 Ø10 3.2 8. 13 22 29.2 40 1 33 0 9 12.8 81.8 44 2 30 40 M4 Ø14 Ø10. 3.2 8. 13 22 28.7 28. 14. 33 7 LO FD 79 FL 79 0 11 1 0 11 1 9 L FD 99 FL 99 10 0 10 0 20 L FD 209 1NO+ 0 9 FL 209 1NO+ 0 9 21 L FD 219 3NC FL 219 3NC 22 L FD 229 2NO+1NC FL 229 2NO+1NC 33 L FD 339 FL 339 FC 339 34 L FD 349 FL 349 FC 349 Min. force 0,1 Nm (0,4 Nm ) 0,1 Nm (0,4 Nm ) 0,1 Nm (0,4 Nm ) How to read travel diagrams NC opening Example diagram Positive opening travel Max travel Closed contact 0 9 11-12 All measures in the diagrams are in degrees IMPORTANT: In safety applications it is necessary to activate the switch at least up to the positive opening point indicated in the diagrams with the symbol. Operate the switch at least with the positive opening force, indicated between brackets, below each article, next the value of minimum force. 23-24 Open contact NO closing Accessories See page /1 All measures in the drawings are in mm page 4/41

Regulation of intervention point 1 Temporary shaft locking (dowel provided). Verify the operating point according to EN 294, adjust the operating point again if necessary Switch locking (pin provided). 1A 1B 2 2A 2B 2C 2D 2E 3 3A 3B 3C 4 4A 4B 4C 4D 4E 4F 4G 4H page 4/42