Safety switches with solenoid and separate actuator

Size: px
Start display at page:

Download "Safety switches with solenoid and separate actuator"

Transcription

1 4D Safety switches with and separate Selection diagram VF KEYF0 VF KEYF VF KEYF VF KEYF8 ACTUATORS DD DE D5D D6D D7D D7E locked with locked with De-energized Energized WORKING PRINCIPE locked with De-energized. With lock release device. locked with De-energized. With lock release device and anti-panic release push button. locked with De-energized. With anti-panic release push button. locked with Energized. With anti-panic release push button. SIGNAING ED A B C Z two green ED red and green ED freely orange and green ED without ED switched-on by the linkable freely linkable power supply CONTACT BOCKS 60A 60B 60C 60D 60E 60F 60G 60H 60I NO+NC NC 3NC NO+NC NO+NC NO+NC NC 3NC NO+NC NO+NC NC NC NC NO NC NO 60 60M 60N 60P 60R 60S 60T 60U 60V NO+NC NO+NC NO+NC NC NO+NC NC NC NC NC NO NO 3NC NO+NC NO+NC NO CONDUIT ENTRIES SOENOID SUPPY VOTAGE 4 V AC/DC 0 V AC 30 V AC Vac/dc (-0%... +5%) 0 Vac (-5%... +0%) 30 Vac (-5%... +0%) V DC Vdc (-5%... +0%) Threaded conduit entries M0 (standard) With M3 metal connector assembled and wired K95 poles from bottom K96 poles from right K97 poles from left page 4/59 General Catalog

2 Code structure Attention! The feasibility of a code number does not mean the effective availability of a product. Please contact our sales office. article options FG 60ADD0A-P30F0GK95 A Integrated contact blocks Solenoid operated Actuator operated 60A NO+NC NO+NC 60B NC NO+NC 60C 3NC NC 60D NO+NC NC 60E NO+NC NC 60F NO+NC NO 60G NC NC 60H / 60I 3NC NO 60 NO+NC NC 60M NO+NC NO 60N NO+NC NO 60P NC 3NC 60R NO+NC / 60S NC NC+NO 60T NC NC+NO 60U / 60V NC NO Working principle DD locked with de-energized DE locked with energized D5D D6D D7D D7E locked with de-energized. With lock release device. locked with de-energized. With lock release device and anti-panic release push button. locked with de-energized. With anti-panic release push button. locked with energized. With anti-panic release push button. Solenoid supply voltage 0 4 Vac/DC (-0%... +5%) 0 Vac (-5%... +0%) 30 Vac (-5%... +0%) 3 Vdc (-5%... +0%) Signalling ED A B C Z Contacts type silver contacts (standard) G silver contacts gold plated µm Actuators without F0 with straight F with right-angled F with with rubber mountings F8 with universal Release button length Wall thickness length max 5 mm (standard) P30 Wall thickness length max 30 mm P Wall thickness length max mm P60 Wall thickness length max 60 mm PRG two green ED switched-on by the power supply red and green ED freely linkable orange and green ED freely linkable without ED Preinstalled connectors no connectors (standard) K95 K96 K97 Adjustable for wall thickness length from 60 mm to 500 mm with M3 metal connector assembled and wired, poles from bottom with M3 metal connector assembled and wired, poles from right with M3 metal connector assembled and wired, poles from left B A B C D E 3 3A 3B 3C 4 4A 4B 4C 4D 4E 4F 4G 4H 5 6 General Catalog page 4/60

3 4D Safety switches with and separate Housing Metal housing, coated with baked epoxy powder. Three conduit entries M0 Protection degree: IP67 according to EN 6059 (electrical contacts) Patent pending Main features Actuator holding force 500 N 0 contact blocks with 4 contacts Metal housing, three conduit entries M0 Protection degree IP67 Version with lock release device and emergency release push button 4 stainless steel s Rotating head and devices and not detachable Signalling ED Working with energized or de-energized Markings and quality marks: General data Safety parameters: see page 6/3 Ambient temperature: from -5 C to +60 C Max operating frequency: 600 operations cycles /hour Mechanical endurance: million of operations cycles Max actuating speed: 0,5 m/s Min. actuating speed: mm/s Max holding force: 500 N Maximum force before the breaking in accordance with GS-ET-9: 800 N Maximum holding force in accordance with GS-ET-9: 50 N Max backlash of the : 4,5 mm Actuator extraction force: 30 N Driving torque for installation: see pages 6/-6/0 () One operation cycle means two movements, one to close and one to open contacts, as foreseen by EN standard.. Cross section of the conductors (flexible copper wire) Contact blocks: min. x 0,34 mm ( x AWG ) max. x,5 mm ( x AWG 6) In conformity with standards: IEC , EN , IEC 6004-, EN 6004-, EN 088, EN ISO 00-, EN ISO 00-, IEC 6059, EN 6059, EN , EN , NFC 63-, VDE , VDE 03, CENEEC EN 5003, BG-GS-ET-5. Approvals: IEC , U 508 In conformity with requirements requested by: ow Voltage Directive 006/95/EC, Machinery Directive 006/4/EC and Electromagnetic Compatibility 004/08/EC. Positive contact opening in conformity with standards: IEC , EN , VDE Approval IMQ: Approval U: CA E3787 Solenoid Solenoid duty cycle: Solenoid protection V: Solenoid protection 4 V: Solenoid protection 0 V: Solenoid protection 30 V: Solenoid power: 00% ED fuse A type gg fuse 0,5 A type gg fuse 35 ma, delayed type fuse 35 ma, delayed type 9 VA If not expressly indicated in this chapter, for the right installation and the correct utilization of all articles see requirements indicated from page 6/ to page 6/0. Electrical data Utilization categories without connector Thermal current (Ith): 0 A Rated insulation voltage (Ui): 0 Vac 300 Vdc Conditional shot circuit current: 000 A according to EN Protection against short circuits: fuse 0 A 500 V type gg Pollution degree: 3 Alternate current: AC5 ( Hz) Ue (V) Ie (A) Direct current: DC3 Ue (V) Ie (A) 3 0,7 0,4 with poles M3 connector Thermal current (Ith): 8 A Rated insulation voltage (Ui): 50 Vac 300 Vdc Protection against short circuits: fuse 8 A 500 V type gg Pollution degree: 3 Alternate current: AC5 ( Hz) Ue (V) 0 50 Ie (A) 6 5 Direct current: DC3 Ue (V) Ie (A) 3 0,7 0,4 page 4/6 General Catalog

4 Data type approved by IMQ Rated insulation voltage (Ui): 0 Vac Thermal current (Ith): 0 A Protection against short circuits: fuse 0 A 500 V type am Protection degree: IP67 MV terminals (screw clamps) Pollution degree 3 Utilization category: AC5 Operation voltage (Ue): 0 Vac (50 Hz) Operation current (Ie): 3 A Forms of the contact element: X+X+X+X, Y+Y+Y+Y, X+Y+Y+Y, X+X+Y+Y, X+X+X+Y Positive opening of contacts on contact block 60A, 60B, 60C, 60D, 60E, 60F, 60G, 60H, 60I, 60, 60M, 60N, 60P, 60R, 60S, 60T, 60U, 60V In conformity with standards: EN , EN and subsequent modifications and completions, fundamental requirements of the ow Voltage Directive 006/95/CE and subsequent modifications and completions. Please contact our technical service for the list of approved products. Do imits not use of where utilization dust and dirt may penetrate in any way into the head and deposit there, in particular where metal dust, concrete or chemicals are spread. Do not use where explosive or inflammable gas is present. Use Atex products in environments with explosion hazard (see page /37) Data type approved by U Utilization categories A300 (70 VA, Vac) Q300 (69 VA, 5-50 Vdc) Data of the housing type, 4X indoor use only,, 3 In conformity with standard: U 508 Please contact our technical service for the list of approved products. A B A B C D E 3 3A 3B 3C 4 4A 4B 4C 4D 4E 4F 4G 4H 5 6 General Catalog page 4/6

5 4D Safety switches with and separate These switches are used on machines where the hazardous conditions remain for a while, even after the machines has been switched off, for example because of mechanical inertia of pulleys, saw disks, parts under pressure or with high temperatures. They can also be used when it is necessary to control machine guards allowing the opening of protections only under specific conditions. Actuator holding force The strong interlocking system guarantees a maximum holding force of 500 N. Actuating regulation zone This switch has a wide backlash of the into the head (4,5 mm) to avoid that door gaskets keep in traction the on the. With closed door, check that the doesn t knock straight against the head of the switch; it must be in the adjustment zone (0,5 5 mm) 0, mm Rotating heads and devices The head can be quickly rotated on each of the 4 sides of the switch by unfastening the four fixing screws. Also the lock release device and the release button can be rotated in 90 steps; this enables the switch to assume 3 different configurations. 4 poles contact block Innovative 4 poles contact block, available in different contacts configurations to monitor the or the (patented). The contact block is supplied with no-loosing screws and self-lifting plates Release device with rotating lock The auxiliary release device with rotating lock is used to allow the maintenance or the entry into the machinery to authorized personnel only. Rotating the key, will make the same action of the, that is move contacts and release the. The device can be rotated allowing the installation of the safety switch inside the machinery and making the release device accessible outside the protection. In this way, the switch is more protected against possible tampering and the external side/surface of the machinery remains pleasant. Emergency release push button This device is used when the safety switch controls hazardous areas where operators may physically enter with all their body. The release button, oriented towards inside the machinery, allows the exit of the operator accidentally trapped also in case of possible black-out. Pushing the button, it will be actuated the same function of the auxiliary release device. To reset the switch, restore the button to the initial position. The emergency button can be rotated, available with different lengths and it is fixed to the switch by a screw, so to allow the installation of the switch inside or outside the guards. ock release device and emergency push button This device performs the two above mentioned functions at the same time. Also in this case the device can be rotated and the release button can be ordered with different lengths. The activation of the button has the priority on the lock, that is with the closed lock is possible to activate the button and unlock the switch. To reset the switch is necessary to restore lock and button to their initial position. Not detachable head and devices The head and the release devices can be rotated but they are not detachable to each other. In such a way the switch is safer because the installer do not have to worry about the assembly of various components and there is a lower probability of damages (loss of small parts, dirt penetration, etc.) Signalling ED type A In the version with signalling ED type A, two green ED are switched-on directly by the power supply. Wiring is not necessary. A Signalling ED type B In the version with signalling ED type B, two ED connection wires are available, one green and one red. Through suitable connections to the contact block, it is possible to control the different s of the switch. A A A page 4/63 General Catalog

6 Working conditions The working principle of these safety switches allows three different working s: A : with the inserted and blocked by the B : with the inserted but not blocked C : with the extracted All or some of these s may be controlled through the positive opening contacts of the internal contact block. In detail, contact blocks that have electric contacts marked with the symbol of the ( ) are switched in the transition between the A and B, while the electric contacts marked with the symbol of the ( ) are switched between B and C: Working principle It is also possible to choose between two working principles for the locking: Working principle D: Actuator blocked with de-energized. Actuator release is obtained by power supply to the (see example of working cycle steps). Working principle E: Actuator blocked with energized. The unlock of the is obtained by power-off to the. It is advisable to use this version under special conditions because a blackout will allow the immediate opening of the protection. Product versatility This series of products includes many technical solutions that results in easier installation and working: Four different types of stainless steel s, suitable to be fixed in several positions and with insertion radius arc equal to or over 80 mm. Swinging head, in 90 steps, with two entries for easy installation of the switch. Heads D5, D6 and D7 are provided with release devices that can be rotated independently to the entry side. All parts of heads are rotating but not detachable from the body, in order to avoid any tampering or wrong assembling during the installation. To extract the inserted but not blocked, a 30 N force is necessary, that avoids the guard opening because of vibrations or impacts. Extremely heavy mechanical system of locking, able to support traction forces up to 500 N. When is locked, it can still move a little (4,5 mm), to avoid that door gaskets keep in traction the on the. Housing with three conduit entries for an easier installation or connection in series. Electronic control of the power supply, which allow a wide tolerance on supply voltage. This technical solution resolves the problems that may derive from not stable power supply (machine distance from main transformers, tension variation between night/day hours), allowing also a low power Two orthogonal entries Auxiliary release device Working principle D only Head rotates in 90 increments Head and housing made of metal sealable with rotating lock with release push button Signalling ED (optional) 4 contacts with double interruption with release push button and with rotating lock Three cables entries consumption and consequently enlarging the working temperatures range of the switch. No-loosing screws contact blocks, fingers protection, contacts with double interruption, high contact reliability. Version with signalling ED connected to the power supply or freely linked by the installer. ED are externally visible through the housing cover. Release device Versions with D working principle are supplied with a sealable auxiliary release device used by technicians during the installation or to access the machine in case of black-out. Head D: The auxiliary release device is actuated by screwing to the end the safety dowel and rotating the device by 80. The arrow on the switch cover indicates the auxiliary release device. After the release, put in the start position and reposition the safety dowel. To avoid improper use of the auxiliary release device during the usual machine working cycle, it has to be sealed with some drops of paint or by lead sealing. Head D5: The auxiliary release device is composed of a lock with double key supplied on issue. Head D7: The auxiliary release device is composed of a mushroom-head push button with no panic functions. This device must be rotated towards the inner and dangerous side of the machine so that an operator entrapped could activate it, release the switch and go out of the area. To restore the switch, reset the push button. This device cannot be used for functions of emergency stop of the machine. Head D6: This head has contemporaneously functions of heads D5 and D7. The release occurs always, any of two devices is activated (push button or lock). Gate monitoring These switches alone cannot protect operators or maintenance men where they may physically enter with all their body in the hazardous area, because an involuntary closing of the protection behind them could allow the restart of the machine. If the authorization to the machine restart is completely granted by these switches, it must be foresee a system to avoid that risk, as for example the pad lockable device to lock the entry, item VF KB at page 4/70 or a safety handle with padlocks as for example VF AP-PB-00P (page 4/93). A B A B C D E 3 3A 3B 3C 4 4A 4B 4C 4D 4E 4F 4G 4H 5 6 General Catalog page 4/64

7 4D Safety switches with and separate Example of working cycle steps with FG 60ADD0A-F (switch with working principle D) STOP GUARD UNOCKING COMMAND OPENING OF THE GUARD When the switch is in C, energized or de-energized the do not influence the contacts position. Step Step Step 3 Step 4 Step 5a Step 5b A A A B C C Machine working Machine slowing down Machine stopped Machine stopped Machine stopped Machine stopped Actuator locked Actuator locked Actuator locked Actuator unlocked Actuator extracted Actuator extracted START GUARD OCKING COSING OF THE GUARD The GUARD COSING with de-energized brings the switch back in B and then in A in quick sequence. Application examples on machinery guards page 4/65 General Catalog

8 Contacts position in switch s Operation A Working principle D locked with de-energized B C A Working principle E locked with energized B Actuator Inserted and locked Inserted and unlocked Extracted Inserted and locked Inserted and unlocked Extracted Solenoid De-energized Energized - Energized De-energized - C A B FG 60A NO+NC controlled by the NO+NC controlled by the FG 60B NC controlled by the NO+NC controlled by the FG 60C 3NC controlled by the NC controlled by the FG 60D NO+NC controlled by the NC controlled by the FG 60E NO+NC controlled by the NC controlled by the FG 60F NO+NC controlled by the NO controlled by the FG 60G NC controlled by the NC controlled by the FG 60H controlled by the FG 60I 3NC controlled by the NO controlled by the FG 60 NO+NC controlled by the NC controlled by the FG 60M NO+NC controlled by the NO controlled by the FG 60N NO+NC controlled by the NO controlled by the FG 60P NC controlled by the 3NC controlled by the FG 60R NO+NC controlled by the FG 60S NC controlled by the NO+NC controlled by the FG 60T NC controlled by the NO+NC controlled by the FG 60U controlled by the FG 60V NC controlled by the NO controlled by the A B C D E 3 3A 3B 3C 4 4A 4B 4C 4D 4E 4F 4G 4H 5 6 General Catalog page 4/66

9 4D Safety switches with and separate Dimensional drawings Contacts type: = slow action Switch with D working principle with sealable auxiliary release device, supplied without.3 Switch with E working principle, supplied without.3 Switch with D working principle with lock release device, supplied without.3 Contact blocks A 60B 60C 60D 60E 60F 60G 60H 60I 60 60M 60N 60P 60R 60S 60T 60U 60V Min. force Travel diagrams FG 60ADD0A NO+NC NO+NC FG 60BDD0A NC NO+NC FG 60CDD0A 3NC NC FG 60DDD0A NO+NC NC FG 60EDD0A NO+NC NC FG 60FDD0A NO+NC NO FG 60GDD0A NC NC FG 60HDD0A / FG 60IDD0A 3NC NO FG 60DD0A NO+NC NC FG 60MDD0A NO+NC NO FG 60NDD0A NO+NC NO FG 60PDD0A NC 3NC FG 60RDD0A NO+NC / FG 60SDD0A NC NO+NC FG 60TDD0A NC NO+NC FG 60UDD0A FG 60VDD0A NC NO 30 N (60 N ) page 4/68 - group FG 60ADE0A NO+NC NO+NC FG 60BDE0A NC NO+NC FG 60CDE0A 3NC NC FG 60DDE0A NO+NC NC FG 60EDE0A NO+NC NC FG 60FDE0A NO+NC NO FG 60GDE0A NC NC FG 60HDE0A / FG 60IDE0A 3NC NO FG 60DE0A NO+NC NC FG 60MDE0A NO+NC NO FG 60NDE0A NO+NC NO FG 60PDE0A NC 3NC FG 60RDE0A NO+NC / FG 60SDE0A NC NO+NC FG 60TDE0A NC NO+NC FG 60UDE0A FG 60VDE0A NC NO 30 N (60 N ) page 4/68 - group FG 60AD5D0A NO+NC NO+NC FG 60BD5D0A NC NO+NC FG 60CD5D0A 3NC NC FG 60DD5D0A NO+NC NC FG 60ED5D0A NO+NC NC FG 60FD5D0A NO+NC NO FG 60GD5D0A NC NC FG 60HD5D0A / FG 60ID5D0A 3NC NO FG 60D5D0A NO+NC NC FG 60MD5D0A NO+NC NO FG 60ND5D0A NO+NC NO FG 60PD5D0A NC 3NC FG 60RD5D0A NO+NC / FG 60SD5D0A NC NO+NC FG 60TD5D0A NC NO+NC FG 60UD5D0A FG 60VD5D0A NC NO 30 N (60 N ) page 4/68 - group How to read travel diagrams Contacts controlled by the Contacts controlled by the NC opening and NO closing Positive opening travel NC opening NO closing Max travel Closed contact Open contact Example diagram All measures in the diagrams are in mm IMPORTANT: NC contact has to be considered with inserted and locked. In safety applications it is necessary to activate the switch at least up to the positive opening point indicated in the diagrams with the symbol. Operate the switch at least with the positive opening force, indicated between brackets, below each article, next the value of minimum force. Accessories See page 5/ All measures in the drawings are in mm page 4/67 General Catalog

10 Contacts type: = slow action Switch with D working principle, with lock release device and release push button, supplied without Ø38 Ø7 Switch with D working principle, with release push button, supplied without Ø Ø Switch with E working principle, with release push button, supplied without Ø Ø A B max A B Contact blocks C 60A 60B 60C 60D 60E 60F 60G 60H 60I 60 60M 60N 60P 60R 60S 60T 60U 60V Min. force Travel diagrams 60A NO+NC 60B NO+3NC FG 60AD6D0A NO+NC NO+NC FG 60BD6D0A NC NO+NC FG 60CD6D0A 3NC NC FG 60DD6D0A NO+NC NC FG 60ED6D0A NO+NC NC FG 60FD6D0A NO+NC NO FG 60GD6D0A NC NC FG 60HD6D0A / FG 60ID6D0A 3NC NO FG 60D6D0A NO+NC NC FG 60MD6D0A NO+NC NO FG 60ND6D0A NO+NC NO FG 60PD6D0A NC 3NC FG 60RD6D0A NO+NC / FG 60SD6D0A NC NO+NC FG 60TD6D0A NC NO+NC FG 60UD6D0A FG 60VD6D0A NC NO 30 N (60 N ) page 4/68 - group Travel diagrams table Contact blocks 0 60C D NO+3NC E NO+3NC 0 60F NO+NC Group Contact blocks FG 60AD7D0A NO+NC NO+NC FG 60BD7D0A NC NO+NC FG 60CD7D0A 3NC NC FG 60DD7D0A NO+NC NC FG 60ED7D0A NO+NC NC FG 60FD7D0A NO+NC NO FG 60GD7D0A NC NC FG 60HD7D0A / FG 60ID7D0A 3NC NO FG 60D7D0A NO+NC NC FG 60MD7D0A NO+NC NO FG 60ND7D0A NO+NC NO FG 60PD7D0A NC 3NC FG 60RD7D0A NO+NC / FG 60SD7D0A NC NO+NC FG 60TD7D0A NC NO+NC FG 60UD7D0A FG 60VD7D0A NC NO 60G 0 60H I NO+3NC 0 60 NO+3NC 0 60M 3NO+NC N 3NO+NC 0 30 N (60 N ) page 4/68 - group Group FG 60AD7E0A NO+NC NO+NC FG 60BD7E0A NC NO+NC FG 60CD7E0A 3NC NC FG 60DD7E0A NO+NC NC FG 60ED7E0A NO+NC NC FG 60FD7E0A NO+NC NO FG 60GD7E0A NC NC FG 60HD7E0A / FG 60ID7E0A 3NC NO FG 60D7E0A NO+NC NC FG 60MD7E0A NO+NC NO FG 60ND7E0A NO+NC NO FG 60PD7E0A NC 3NC FG 60RD7E0A NO+NC / FG 60SD7E0A NC NO+NC FG 60TD7E0A NC NO+NC FG 60UD7E0A FG 60VD7E0A NC NO Contact blocks 60P R NO+NC 60S NO+NC 60T NO+3NC 60U 30 N (60 N ) page 4/68 - group V NO+NC 0 Group D E 3 3A 3B 3C 4 4A 4B 4C 4D 4E 4F 4G 4H 5 6 Items with code on the green background are available in stock General Catalog page 4/68

11 4D Safety switches with and separate Stainless steel s IMPORTANT: These s must be used with FG series only (e.g. FG 60ADD0A) VF KEYF0 Straight VF KEYF R R 0.5 R 0 VF KEYF Actuator with rubber mountings 9,5 0 9,5 5, R 300 R 0 50,5 8,6 Ø , 3,5 7 Right-angled R R 0.5 R 0 R 0 Universal VF KEYF8 VF KEYF8 Universal R M IMPORTANT: These s must be used with FG series only (e.g. FG 60ADD0A) R 80 R 80 Joined and two directions adjustable for doors with reduced dimensions. The has two couples of fixing holes and it is possible to rotate the -working plan (see picture). For inaccurate doors inside outside Accessories See page 5/ page 4/69 General Catalog

12 Accessories for sealing Pliers, steel wire and lead seals used to seal the auxiliary release device. VF FSPB-00 VF FSPB-0 VF FSFI-0 VF FSFI-0 VF FSPZ Set of 00 lead seals Set of 0 lead seals 0 m steel wire roll 0 m steel wire roll Plier without logo A B A B Accessories C VF KB Actuator entry locking device VF KA37 Set of locking keys D Padlockable device to lock the entry in order to prevent from the accidental closing of the door behind operators while they are inside the machine. To be used only with FG series. Extra copy of the locking keys to be purchased if further keys are needed (standard supply units). All switches keys have the same code. Other codes on request. E 3 3A 3B 3C 4 4A 4B 4C 4D 4E 4F 4G 4H 5 6 Items with code on the green background are available in stock General Catalog page 4/70

13 4D Safety switches with and separate Other release button lengths MIN 5 MAX Ø 38 Ø 38 Ø 38 Ø38 Ø 7 Ø7 Ø 7 Ø7 30 max MAX 60 MAX 60 MIN 500 MAX P30 -P -P60 -PRG Wall thickness length from 5 to 30 mm Wall thickness length from 30 to mm Wall thickness length from to 60 mm Wall thickness length mm - Avoid torsion and bending on the release button bar. - Use a bushing or a tube with 8±0,5 mm diameter as a guide inside the wall. - The M0 threaded bar has to be inserted into the guide in order to avoid its bending. The M0 threaded bar is not supplied with the device. - To guarantee the device correct operation, keep a distance of 0 to 5 mm between the wall and the release button. - Keep clean the release push button slipping area. The guide bushing or tube must be cleaned inside, since dirt or chemical products could compromise the device operation. Safety modules Pizzato Elettrica s.r.l. offers its customers a wide range of safety modules maded considering the typical problems about the control of the safety switches and their real use conditions. There are available safety modules with instantaneous or delayed contacts suitable for type 0 (immediate stop) or type (monitored stop) emergency circuits. Safety switches with series FG could be connected to safety modules in order to obtain safety circuits up to Pe in accordance with EN ISO For any technical information or wiring diagram please contact our technical staff. /+ F F F F F K STOP START K K K A Y Y 7 A S S S3 S33 S Safety timer module CS FS-0 Safety module CS AR-08 A 8 Safety switch A S S S K K A N/- A M FG 60ADD0A page 4/7 General Catalog

14 Notes A B A B C D E 3 3A 3B 3C 4 4A 4B 4C 4D 4E 4F 4G 4H 5 6 General Catalog page 4/7

Safety switches with solenoid and separate actuator

Safety switches with solenoid and separate actuator Safety switches with and separate Selection diagram ACTUATORS VF KEYF20 VF KEYF21 VF KEYF22 VF KEYF28 D1D D1E D5D D6D D7D D7E locked with energized locked with de-energized locked with de-energized with

More information

Safety switches with solenoid and separate actuator

Safety switches with solenoid and separate actuator 4 Safety switches with and separate Selection diagram VF KEYF20 VF KEYF21 VF KEYF22 VF KEYF28 CTUTORS HED TYPE ND WORKING PRINCIPE D locked with de-energized E locked with energized SIGNING ED B Z two

More information

Safety switches with solenoid and separate actuator

Safety switches with solenoid and separate actuator 4 Safety switches with solenoid and separate Selection diagram VF KEYF20 VF KEYF VF KEYF22 VF KEYF28 CTUTORS D1D locked with De-energized solenoid WORKING PRINCIPLE D1E locked with Energized solenoid D5D

More information

Safety switches with solenoid and separate actuator

Safety switches with solenoid and separate actuator Safety switches with solenoid and separate actuator These switches are used on machines where the hazardous conditions remain for a while, even after the machines have been switched off, for example because

More information

Safety switches with solenoid and separate actuator

Safety switches with solenoid and separate actuator Safety switches with solenoid and separate actuator These switches are used on machines where the hazardous conditions remain for a while, even after the machines have been switched off, for example because

More information

Safety switches for hinged doors

Safety switches for hinged doors 4C Safety switches for hinged doors Selection diagram CONTACT BLOCKS 18 7 9 20 overlapped 1NO+ FD FL FC 21 22 33 34 2NO+1NC 3NC CONDUIT ENTRIES Threaded conduit entries (standard) With cable gland assembled

More information

Safety switches for hinged doors

Safety switches for hinged doors 4 Safety switches for hinged doors Selection diagram FR FM FX FZ FK 5 18 7 9 snap action overlapped CONTACT BLOCKS 20 21 22 33 34 1NO+ CONDUIT ENTRIES Threaded conduit entries (standard) With cable gland

More information

Position switches FC series

Position switches FC series A Position switches FC series Selection diagram 0 08 8 9 0 0 0 Ø 8 mm Ø, mm external rubber stainless steel stainless steel fiber glass rod gasket sphere sphere 6 adjustable lever safety adjustable lever

More information

Safety switches with separate actuator

Safety switches with separate actuator Safety switches with separate actuator Selection diagram VF KEYD VF KEYD1 VF KEYD VF KEYD VF KEYD5 ACTUATORS VF KEYD6 VF KEYD7 VF KEYD8 VF KEYD10 VF KEYD11 FR FX FK FW 5 6 7 11 1 14 NC NC slow action slow

More information

Position switches FR series

Position switches FR series Position switches FR series Selection diagram 0 A 08 0-0 A A 0 A external rubber gasket external rubber gasket for electrical panels external rubber gasket external rubber gasket external rubber gasket

More information

Position switches FD series

Position switches FD series Position switches FD series Selection diagram 01 08 11 18 19 02 04 05 Ø 8 mm Ø, mm external rubber stainless steel stainless steel fibber glass rod gasket sphere sphere 51 52 5 56 41 42 adjustable lever

More information

Safety switches with separate actuator

Safety switches with separate actuator Safety switches with separate actuator Selection diagram VF KEYD VF KEYD1 VF KEYD VF KEYD VF KEYD5 VF KEYD6 VF KEYD7 VF KEYD8 VF KEYD10 VF KEYD11 ACTUATORS CONTACT BLOCKS FR FX FK FW 5 6 7 11 1 14 NC NC

More information

Single foot switches PX and PA series

Single foot switches PX and PA series A Single foot switches PX and PA series Selection diagram CARRYING ROD See page /10 ADDITIONAL METAL PROTECTION OPEN PROTECTIONS CLOSED PROTECTIONS PA PA 2 CONTACT BLOCKS COMBINATIONS 01 02 1NO+1NC snap

More information

Safety switches with solenoid and separate actuator

Safety switches with solenoid and separate actuator Safety switches with and separate These switches are used on machines where the hazardous conditions remain for a while, even after the machines have been switched off, for example because of mechanical

More information

Prewired position switches FF series

Prewired position switches FF series 2 Prewired position switches FF series Distributed buy Selection diagram 01 08 10 11 1 15 1 02 external rubber gasket external rubber gasket 1 52 54 55 56 5 ACTUATORS adjustable lever safety adjustable

More information

Position switches FR series

Position switches FR series Position switches FR series Selection diagram 01 A1 08 14 01-7 0 A 05 A5 external rubber gasket external rubber gasket for electrical panels external rubber gasket external rubber gasket 0 1 5 34 50 33

More information

Rope safety switches with reset for emergency stop

Rope safety switches with reset for emergency stop Rope safety switches with reset for emergency stop Description and technical data hese rope operated safety switches are installed on machines or conveyor belts, to activate the emergency stop of the machine

More information

Prewired position switches FF series

Prewired position switches FF series 2 Prewired position switches FF series Selection diagram 01 08 10 11 1 15 1 02 external rubber gasket external rubber gasket 1 52 54 55 56 5 ACTUATORS adjustable lever safety adjustable lever 41 45 46

More information

Switches with manual reset

Switches with manual reset Switches with manual reset Selection diagram 01-W 02-W 05-W 0-W -W -H0W 16-W 16-H0W Ø mm roller Ø mm roller Ø mm roller Ø mm roller 0-W 1-W 51-W 52-W 5-W 55-W -W adjustable lever safety adjustable lever

More information

Safety rope switches with reset for emergency stop

Safety rope switches with reset for emergency stop Safety rope switches with reset for emergency stop Selection diagram 8 8 83 ACTUATORS ACTUATORS CONTACT BLOCKS 18 9 21 1NO+ FP FD FL FC 22 33 34 LED signalling light CONDUIT ENTRIES For other available

More information

Safety rope switch with reset for emergency stop

Safety rope switch with reset for emergency stop Safety rope switch with reset for emergency stop Selection diagram 8 8 83 ACTUATORS ACTUATORS CONTACT BLOCKS 18 9 21 1NO+,, FP FD FL FC 22 33 34,, CONDUIT ENTRIES Threaded conduit entries (standard) With

More information

LR-LX-LK-LW Safety Switches with separate actuator

LR-LX-LK-LW Safety Switches with separate actuator LR-LX-LK-LW Safety Switches with separate actuator Technopolymer housing, from one to three conduit entries Protection degree IP67 15 contact blocks available 8 stainless steel actuators available Versions

More information

Microswitches MK series

Microswitches MK series D Microswitches MK series Introduction Microswitches of MK series have been developed in order to add new features to traditional and tested microswitches of Pizzato Elettrica (cross-reference at page

More information

Single foot switches PX and PA series

Single foot switches PX and PA series Single foot switches PX and PA series Technical data Housing Made of polymer glass-reinforced shock-proof thermoplastic resin with double insulation Bedplate with non-skid rubber feet. Actuation force:

More information

Safety switches for hinges

Safety switches for hinges Safety switches for hinges Selection diagram ACTUATORS L L6 L9 L16 FR FM FX FZ FK CONTACT BLOCKS 6 7 9 14 18 snap action 1NO+1N, make before break, shifted, close 21 4 66 NC 2NO+ 1NO+ CONDUIT ENTRIES Threaded

More information

Microswitches M series

Microswitches M series Microswitches M series Technical data Housing Made of glass-reinforced polymer, self-extinguishing, shock-proof thermoplastic resin. Protection degree: IP40 (with protection art. VF C0) IP0 (with protection

More information

Microswitches MK series

Microswitches MK series Microswitches MK series Microswitches of MK series have been developed in order to add new features to traditional and tested microswitches of Pizzato Elettrica. These products have been designed with

More information

FL series position switches

FL series position switches FL series position switches Selection diagram 0 08 0 9 0 0 0 Ball Ø. External rubber Ball Ø 8 mm, mm, stainless Glass fibre rod gasket stainless steel steel Adjustable lever Adjustable safety lever Bistable

More information

Safety rope switch without reset for simple stop

Safety rope switch without reset for simple stop afety rope switch without reset for simple stop election diagram FP 4-M2 FD 4-M2 FL 4-M2 FR 4-M2 FM 4-M2 FX 4-M2 FZ 4-M2 ACTUATOR 9 ACTUATOR 9 0 CONTACT BLOCK 1 9 21 1NO+ FP FD FL FC 33 34 CONDUIT ENTRIE

More information

LK Position Switches TECHNICAL DATASHEET.

LK Position Switches TECHNICAL DATASHEET. LK Position Switches Technopolymer housing, one conduit entry Protection degree IP6 according to EN 60529 contact blocks available 46 actuators available Versions with stainless steel external parts Versions

More information

Single foot switches - PX and PA series

Single foot switches - PX and PA series Single foot switches - PX and PA series Description The PX and PA foot switches are traditional products of Pizzato Elettrica that have recorded a continuous growth and success in the market. Modified

More information

Switches in conformity with ATEX directive

Switches in conformity with ATEX directive Switches in conformity with ATX directive 2/3 General Catalog -2 Technical concepts page 2/39 Position switches FD series page 2/4 Category Zone PL Approvals 2G Gb Mb II 2G x ia IIC T6 Gb I x ia I Mb Article

More information

Switches in conformity with ATEX directive

Switches in conformity with ATEX directive Switches in conformity with ATX directive 2/3 General Catalog 3-4 Technical concepts page 2/39 Position switches FD series page 2/4 Category Zone PL Approvals 2G Gb Mb II 2G x ia IIC T6 Gb I x ia I Mb

More information

Microswitches MK Series

Microswitches MK Series General purpose microswitches for heavier duty applications High precision snap action mechanism 16A 250V AC resistive rating (I th ) Wide range of actuator styles Screw terminals with self lifting plate

More information

Safety handles P-KUBE line

Safety handles P-KUBE line Safety handles -KUE line Introduction To apply safety switches on machinery guards it is necessary to confront with practical issues relating to ease of installation, precise mechanical movements of the

More information

D4DL. Guard Lock Safety-door Switch. Ordering Information. Model Number Legend Switches D4DL- -

D4DL. Guard Lock Safety-door Switch. Ordering Information. Model Number Legend Switches D4DL- - Guard Lock Safety-door Switch Polymer housing, IP65, and slow-action contacts with positive opening. 2 versions Mechanical lock/solenoid release Solenoid lock/mechanical release Rotatable operating head

More information

SFS-UFS Single Foot Switches

SFS-UFS Single Foot Switches SFS-UFS Single Foot Switches Technopolymer housing, shock proof Protection degree IP53 or IP65 13 contact blocks available Various auxiliary devices available UFS Series SFS Series Options & Ordering Codes

More information

D4DL. Guard Lock Safety-door Switch. Model Number Structure

D4DL. Guard Lock Safety-door Switch. Model Number Structure Guard Lock Safety-door Switch Two new types added to series: Mechanical-lock models that lock automatically when the Operation Key is inserted, and solenoid-lock models that lock when voltage is applied

More information

AZM 161SK 12/12RKED/TU 024

AZM 161SK 12/12RKED/TU 024 10.06.2016 10:17:13h Datasheet AZM 161SK 12/12RKED/TU 024 Solenoid interlock / AZM 161 Thermoplastic enclosure Double insulated Interlock with protection against incorrect locking. 130 mm x 90 mm x 30

More information

Technical data. Standards: IEC/EN ; EN ISO ; EN 1088; BG-GS-ET-19

Technical data. Standards: IEC/EN ; EN ISO ; EN 1088; BG-GS-ET-19 1 echnical data echnical data, 1 0 3 1 104 7 90 Interlock with protection against incorrect locking hermoplastic enclosure contacts Manual release, emergency exit or emergency release Long life Double

More information

Ordering details. Approval. Classification. Global Properties :18:33h. Solenoid interlock / AZM 161

Ordering details. Approval. Classification. Global Properties :18:33h. Solenoid interlock / AZM 161 10.06.2016 10:18:33h Datasheet AZM 161SK 12/12RKED/TU 110/230 Solenoid interlock / AZM 161 Thermoplastic enclosure Double insulated Interlock with protection against incorrect locking. 130 mm x 90 mm x

More information

SERIES AZM170. Solenoid-Latching Machine Guard Safety Interlock Switch. Features & Benefits. Description. Typical Applications

SERIES AZM170. Solenoid-Latching Machine Guard Safety Interlock Switch. Features & Benefits. Description. Typical Applications SERIES AZM170 Description The AZM170 Series is designed for machines/work cells where access to a hazardous work area must be controlled until safe conditions exist. Their solenoid-latching feature permits

More information

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure.

D4BL. Protective Doors Are Locked Until Machines Completely Stop Operating. Guard Lock Safety-door Switch. Model Number Structure. Guard Lock Safety-door Switch Protective Doors Are Locked Until Machines Completely Stop Operating A mechanical lock is applied automatically when the Operation Key is inserted. A high level of safety

More information

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

For full product information, visit  Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. Safety Interlock Switches D4JL D4JL For full product information, visit www.sti.com. Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. uard Lock Safety-Door Switch Holding

More information

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

For full product information, visit  Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. Courtesy of CMA/Flodyne/Hydradyne Motion Control Hydraulic Pneumatic Electrical Mechanical (00) 6-0 www.cmafh.com Safety Interlock Switches DSL-N Super Small Class 6-Contact uard Lock Safety-Door Switch

More information

D4DL. Ordering Information. Compact Guard-locking Interlock Safety Door Switch. Model Number Legend Switches D4DL- -

D4DL. Ordering Information. Compact Guard-locking Interlock Safety Door Switch. Model Number Legend Switches D4DL- - Compact Guard-locking Interlock Safety Door Switch Polymer housing, IP65, and slow-action contacts with positive opening. 2 versions Mechanical lock/solenoid release Solenoid lock/mechanical release Rotatable

More information

SG-B1 SERIES / SG-A1 SERIES

SG-B1 SERIES / SG-A1 SERIES 643 Door with Solenoid Interlock / Door Ultra-slim SG-B1 SERIES / SG-A1 SERIES Related Information General terms and conditions... F-7 General precautions... P.1501 PHOTO PHOTO Conforming to Machine &

More information

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from

Application Support. Product Information. Omron STI. Support Engineers are available at our USA headquarters from Omron STI Application Support Thank you for your interest in Omron STI products. Please contact Omron STI with your application questions. Support Engineers are available at our USA headquarters from 4:00

More information

Solenoid interlocks AZM 170 range. 98 Schmersal 22 8,2 60. ø4,2. ø Pg 11

Solenoid interlocks AZM 170 range. 98 Schmersal 22 8,2 60. ø4,2. ø Pg 11 2.4 AZM 170 range Features Thermoplastic enclosure Compact design Manual release Long life Double insulated X High holding force 1,000 N N latching force Cut clamp termination Actuation on de-energisation

More information

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information Safety-door Switch Safety-door Switch s Special Operation Key Directly Pulls Apart the Contacts from Each Other and Contributes to the Safety of the Production Site Conforms to EN (TÜV) standards corresponding

More information

For full product information, visit Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page.

For full product information, visit  Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. Safety Interlock Switches D4S-N D4SN For full product information, visit www.sti.com. Use the SpeedSpec Code or scan the QR Code for quick access to the specific web page. Slim Safety Door Switches with

More information

ZB0050 / ZB0051 ZB0070 / ZB0071

ZB0050 / ZB0051 ZB0070 / ZB0071 Operating instructions Safety Rope Emergency Stop Switches UK ZB0050 / ZB0051 ZB0070 / ZB0071 7390877 / 02 08/2013 Contents 1 Safety instructions...3 2 Installation / set-up...4 2.1 Applications...4 2.2

More information

Safety door-handle system STS

Safety door-handle system STS Safety door-handle system STS Full body access ha Safety door-handle system STS EN 1037 Features The safety door-handle system is suitable for all types of safety guards. Safety switches and solenoid interlocks

More information

XCS Safety Interlock Selection

XCS Safety Interlock Selection Steven Engineering-2 Ryan Way-South San Francisco, CA 980-6370-Main Office:(650)588-9200-Outside Local Area:(800)258-9200-www.stevenengineering.com Selection Plastic, Double, Turret Head c, Type, locking

More information

panasonic.net/id/pidsx/global Solve issues related to machine safety and other safety measures with a safety door switch with key!

panasonic.net/id/pidsx/global Solve issues related to machine safety and other safety measures with a safety door switch with key! 655 Door with Key SERIES Related Information General terms and conditions... F-7 General precautions... P.50 PHOTO PHOTO Conforming to Machine & EMC Directives Recognition Certified MEASURE ITY panasonic.net/id/pidsx/global

More information

Safety Limit Switch

Safety Limit Switch Safety Limit Switch D4B-@N CSM_D4B-_N_DS_E_5_1 Snap-action contact with certified direct operation certification. Maintenance, seal, and resistance to shock increased and direct mechanism added. Three-conduit

More information

Solenoid interlocks AZM 161 range Schmersal. a 5,5. Pg11/M16x1,5

Solenoid interlocks AZM 161 range Schmersal. a 5,5. Pg11/M16x1,5 .1 AZM 11 range Features Thermoplastic enclosure Manual and emergency release Long life Double insulated X High holding force, N N latching force Wiring compartment Actuation on de-energisation or energisation

More information

HS5E Miniature Interlock Switches with Solenoid

HS5E Miniature Interlock Switches with Solenoid Small interlock switch with four poles and solenoid. Ideal for applications in small spaces. Compact body. 3 40 46 mm. Four-pole internal switches. Gold-plated contacts. Spring lock and solenoid lock types

More information

Operation Key D4BS - K Head Mounting Direction F: Four mounting directions possible (front-side mounting at shipping)

Operation Key D4BS - K Head Mounting Direction F: Four mounting directions possible (front-side mounting at shipping) Safety-door Switch D4BS The Special Activates a Direct Opening Mechanism to Open the Contacts and Shut Off Control Circuits when Protective Doors Are Opened on Machine Tools or Other Equipment CSM_D4BS_DS_E_6_1

More information

Door Interlock Switches

Door Interlock Switches HSE Series HSE Series Miniature Solenoid Locking Switches Overview X Series E-Stops HSE features: World s smallest 4 contact solenoid interlock switch. (3 x x 46 mm) Four contacts Gold-plated contacts

More information

D4SL. Safety Interlock Switches. Compact 6-Contact Guard Lock Safety-Door Switch NEW! Specifications. Standards and EC Directives

D4SL. Safety Interlock Switches. Compact 6-Contact Guard Lock Safety-Door Switch NEW! Specifications. Standards and EC Directives Safety Interlock Switches DSL Compact -Contact uard Lock Safety-Door Switch Two types are available: a connector type that reduces wiring time and a detachable terminal block type. Robust and durable metal

More information

Manual Reset Limit Switch

Manual Reset Limit Switch Manual Reset Limit Switch A Series of Pull-reset Models Available Ideal for elevators (EN81), escalators (EN115), and conveyors. Positive opening mechanism insulation approved by TÜV and BIA. and double

More information

HS1L Interlock Switches with Solenoid

HS1L Interlock Switches with Solenoid HS1L Interlock Switches with Solenoid 3000N locking strength (largest in class)! * Suitable for large and heavy doors. Same actuator as HS1E (actuator retention force 3000N) Six contacts in a compact housing

More information

F E - Electromagnetic Safety Switch With Separated Actuator. 1 Code Construction. Casing: P: Plastic casing

F E - Electromagnetic Safety Switch With Separated Actuator. 1 Code Construction. Casing: P: Plastic casing Electromagnetic Safety Switch With Separated 1 Code Construction F E - Casing: P: Plastic casing Cable inlet: 5: 3 x (M20x1) Type of FEP: E: Electrical block ( b with excited ) M: Mechanical block ( b

More information

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases Circuit Breakers M4 Page Circuit-Breakers M4 2 for motor protection Auxiliary contacts 3 Signalling switch Auxiliary releases Insulated 3-pole busbar system 4 Terminal block DIN-rail adapters 5 Busbar

More information

GKR/GKL Series Dual Entry Solenoid Key Operated Safety Interlock Switch

GKR/GKL Series Dual Entry Solenoid Key Operated Safety Interlock Switch Series Dual Entry Solenoid Key Operated Safety Interlock Switch FEATURES Solenoid power to lock or power to unlock Side or top key entry Separate switches for key position and solenoid status Available

More information

An Investment in Plant Floor Safety. 802C Safety Cable Pull Switches 802E Hinge Safety Interlock Switches 802F Safety Interlock Switches

An Investment in Plant Floor Safety. 802C Safety Cable Pull Switches 802E Hinge Safety Interlock Switches 802F Safety Interlock Switches An Investment in Plant Floor Safety 802C Safety Cable Pull Switches 802E Hinge Safety Interlock Switches 802F Safety Interlock Switches Notes 2 802C Cable Pull Safety Switches Safety and Application Safety

More information

D4JL/D4JL-SK40 CSM_D4JL_D4JL-SK40_DS_E_10_2

D4JL/D4JL-SK40 CSM_D4JL_D4JL-SK40_DS_E_10_2 Guard Lock Safety-door Switch/Slide key D4JL/D4JL-SK40 CSM_D4JL_D4JL-SK40_DS_E_10_2 Holding Force of 3,000 N Two safety circuits and two monitor contacts provide an array of monitoring patterns. Standard

More information

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content

Operating instructions Solenoid interlock AZM 161../.. 1. About this document. Content Solenoid interlock AZM 11../.. 1. About this document Operating instructions.............pages 1 to ranslation of the original operating instructions 1.1 Function his operating instructions manual provides

More information

Safety Interlock Switches

Safety Interlock Switches Safety Interlock Switches D4BL D4BL uard Lock Safety-Door Switch Release protective cover locks using controller signals or pushbutton switches after the cutting tool stops moving due to inertia A mechanical

More information

D4JL/D4JL-SK40. Guard Lock Safety-door Switch/Slide key

D4JL/D4JL-SK40. Guard Lock Safety-door Switch/Slide key Guard Lock Safety-door Switch/Slide key D4JL/D4JL-SK40 C38I-E-02 Holding Force of 3,000 N Two safety circuits and two monitor contacts provide an array of monitoring patterns. Standard gold-clad contacts

More information

Limit Switch D4D- N. Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark

Limit Switch D4D- N. Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark Limit Switch Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark Features positive opening mechanism (NC contacts only) that opens contacts, thus preventing faulty

More information

Door Interlock Switches

Door Interlock Switches HS5B Series HS5B Series Miniature Interlock Switch HS5B features: mm x mm x 9mm Compact Housing Available with Contact Confi gurations (NO + NC or NC) Flexible Installation: By turning the head of the

More information

Datasheet - TV8S /20Z Safety switch for hinged guards / Hinge safety switch / TV8S 521

Datasheet - TV8S /20Z Safety switch for hinged guards / Hinge safety switch / TV8S 521 Datasheet - TV8S 521-02/20Z Safety switch for hinged guards / Hinge safety switch / TV8S 521 Metal enclosure Good resistance to oil and petroleum spirit Mounting independent of hinge 92 mm x 81,5 mm x

More information

Cable length. 3: 3 m. 4: Adjustable mounting (vertical) 4: 3NC (slow action) 5: 5 m. (Slow-action) Horizontal 1 m D4GS-N1R D4GS-N2R D4GS-N3R D4GS-N4R

Cable length. 3: 3 m. 4: Adjustable mounting (vertical) 4: 3NC (slow action) 5: 5 m. (Slow-action) Horizontal 1 m D4GS-N1R D4GS-N2R D4GS-N3R D4GS-N4R Slim Safety-Door Switch Industry s Smallest Safety-Door Switch (with 3 Contacts) for Use in Space-Confined Areas Slim body design (85 x 30 x 17 mm) suitable for small door applications 2-contact and 3-contact

More information

Solenoid interlocks AZM 415 range. 134 Schmersal 29,5 6,5 24,7. 8,6 Pg 13,5 46,5 24,5

Solenoid interlocks AZM 415 range. 134 Schmersal 29,5 6,5 24,7. 8,6 Pg 13,5 46,5 24,5 2.22 415 range Features Metal enclosure Two switches in one enclosure Problem-free opening of stressed doors by means of bell-crank system Robust design Long life High holding force 3,500 N Adjustable

More information

D4BS CSM_D4BS_DS_E_8_4

D4BS CSM_D4BS_DS_E_8_4 Safety-door Switch CSM DS_E_8_4 The Special Activates a Direct Opening Mechanism to Open the Contacts and Shut Off Control Circuits when Protective Doors Are Opened on Machine Tools or Other Equipment

More information

Solenoid interlocks AZM 190 range. 128 Schmersal ,3 4,5 M20 17,5 23,5

Solenoid interlocks AZM 190 range. 128 Schmersal ,3 4,5 M20 17,5 23,5 2.19 AZM 19 range 13 44 32 2,3 3 1 Features Voltage variants Approvals Thermoplastic enclosure Manual / Emergency release Long life Actuation on de-energisation or energisation Slim design, particularly

More information

D4BL. Guard Lock Safety-door Switch

D4BL. Guard Lock Safety-door Switch Guard Lock Safety-door Switch D4BL CSM_D4BL_DS_E_5_1 Release Protective Cover Locks Using Controller Signals or Pushbutton Switches after the Cutting Tool Stops Moving Due to Inertia A mechanical lock

More information

SIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A

SIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A Non-fusible disconnect switches SIRCO UL98 Non-fusible switches standards UL and CSA sirco-ul_022_b_1_cat The solution for > Power distribution sirco_093_b_1_cat SIRCO 3 x 200 A Strong points > Reliability

More information

HS6B Series Subminiature Interlock Switch

HS6B Series Subminiature Interlock Switch HS6B Series Subminiature Interlock Switch HS6B features: Only 78 x 30 x 15mm Allows highest level of safety by having 3 contacts: dual load contacts + monitoring contact (ISO13849-1, EN954-1) Two actuator

More information

CAUTION CM-SE CM-S21 CM-S41

CAUTION CM-SE CM-S21 CM-S41 CAUTION Safety, Technology & Innovation CM Series Operating Instructions for, CM-S21,, CM-S11, CMS31 CM Series Safety System This information is designed to help suitably qualified personnel install and

More information

2NC (slow-action) Direct. Model. opening

2NC (slow-action) Direct. Model. opening Small Safety Limit Switch CSM DS_E_3_1 Smallest Class of Safety Limit Switches in the World Note: Contact your sales representative for details on models with safety standard certification. The world's

More information

D4GL. Environment-friendly Switch with Direct Opening Contacts. Guard Lock Safety-door Switch. Model Number Structure

D4GL. Environment-friendly Switch with Direct Opening Contacts. Guard Lock Safety-door Switch. Model Number Structure Guard Lock Safety-door Switch Environment-friendly Switch with Direct Opening Contacts Contains no harmful substances, such as lead or cadmium, reducing the burden on the environment. Slim safety-door

More information

Technical data. Standards: IEC/EN EN 574 EN 418. powder-coated Protection class: IP 65. Cable section: max. 1.5 mm V I the :

Technical data. Standards: IEC/EN EN 574 EN 418. powder-coated Protection class: IP 65. Cable section: max. 1.5 mm V I the : 55 Two-hand control panels SEP System components 460 240 190 30 Standards: IEC/EN 60947-5-5 EN 574 EN 418 cast aluminium, powder-coated Protection class: IP 65 Cable section: max. 1.5 mm 2 U i : 440 V

More information

Safety Products. Safety Products. HS5E Series. HS5E Series Miniature Solenoid Locking Switch

Safety Products. Safety Products. HS5E Series. HS5E Series Miniature Solenoid Locking Switch HS5E Series HS5E Series Miniature Solenoid Locking Switch HS5E Key features include: World s smallest 4 contact solenoid interlock switch. (35 40 46 mm.) Four contacts. Gold-plated contacts. Spring lock

More information

Protection Equipment

Protection Equipment Protection Equipment Price Groups 101, 102, 121, 131, 143 /2 Introduction Motor Starter Protectors/ Circuit Breakers SIRIUS 3RV2 Motor Starter Protectors up to 40 A new /7 General data /13 For motor protection

More information

HS5D Miniature Interlock Switches

HS5D Miniature Interlock Switches Head removal detection for safer performance. Head removal detection function turns OFF the main circuit (-) when the head of the is removed. The is the same size as contact interlock switches (HS5B).

More information

IDEM Solenoid Interlock Safety Switches

IDEM Solenoid Interlock Safety Switches KLP/KLM/KL3-SS Series Housing Solenoid locking, tongue (key) interlock operated Power to unlock 90 degree adjustable head One (KLP) or three (KLM, KL3-SS) 1/2 in. female NPT conduit opening 30mm mounting

More information

HS5D Miniature Interlock Switches

HS5D Miniature Interlock Switches HS5D Miniature Interlock Switches Head Removal Detection Function for Safer Performance Clearwater Tech - Phone: 8094.04 - Fax: 8.368.04 - Web: www.clrwtr.com - Email: info@clrwtr.com New Generation Miniature

More information

D4GS-N CSM_D4GS-N_DS_E_7_2

D4GS-N CSM_D4GS-N_DS_E_7_2 Slim Safety Door Switch D4GS-N CSM_D4GS-N_DS_E_7_2 Slim Safety Door Switches with IP67 Rating Slim design with a width of only 17 mm (three-contact models). Reversible design allowing either front or rear

More information

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A ATyS d M Remotely operated Transfer Switching Equipment Transfer switches new The solution for > Applications with an external ATS/AMF controller > Building Management Systems (BMS) atys-md_002_b_1_cat

More information

Safety Switches NP GP TP. More than safety.

Safety Switches NP GP TP. More than safety. Safety Switches NP GP TP More than safety. Safety More than safety. Emil Euchner, the company s founder and inventor of the multiple limit switch, circa 1928. Around the world the Swabian specialists in

More information

Standard Interlock Safety Switches

Standard Interlock Safety Switches Subminiature Only 78 x 30 x 1m Two actuator entrances provide flexibility for installation options Integrated molded cable reduces wiring time IP67 (IEC60529) Direct Opening Action Actuators comply with

More information

Machine & Process Safeguarding Solution Selection Guide

Machine & Process Safeguarding Solution Selection Guide Machine & Process Safeguarding Solution Selection Guide 2015-2016»» Expert Area»» Light Curtains»» Laser Scanners»» Programmable Safety Systems»» Mats and Edges»» Door Switches»» Emergency Stop Devices»»

More information

Safety-door Switch. Ordering Information

Safety-door Switch. Ordering Information Safety-door Switch Safety-door Switch s Special Operation Key Positively Pulls Apart the Contacts from Each Other and Contributes to the Safety of the Production Site Special Operation Key prevents mis-operation.

More information

Btdin RCBO 6000A up to 63A (2P)

Btdin RCBO 6000A up to 63A (2P) Index Pages 1. Descripton... 2 2. Product range... 2 3. Overall dimensions... 2 4. Fixing Connection... 3 5. Generl characteristics.... 4-29 6. Compliance - Approvals... 30 7. Curves... 30-34 8.Auxiliaries-

More information

Operating instructions Solenoid interlock EX-AZM About this document. Content

Operating instructions Solenoid interlock EX-AZM About this document. Content EX-AZM 161 1. About this document Operating instructions.............pages 1 to 6 Translation of the original operating instructions 1.1 Function This operating instructions manual provides all the information

More information

Components for safety applications

Components for safety applications pages / and /35 page /36 Double insulated, turret head, types CS-PA, CS-TA and CS-TE Cable entries tapped M16 x 1.5 Without locking of actuator 1 -pole N/C + N/O CS-PA59 -pole N/O + N/C CS-PA69 -pole N/C

More information

D4DL. Locking Safety-Door Switch. Compact, Locking Safety Door Switch with Dual Key Entry. H Two types in the series: Mechanical-lock

D4DL. Locking Safety-Door Switch. Compact, Locking Safety Door Switch with Dual Key Entry. H Two types in the series: Mechanical-lock Locking Safety-Door Switch Compact, Locking Safety Door Switch with Dual Key Entry H Two types in the series: Mechanical-lock models that lock automatically when the Operation Key is inserted, and solenoid-lock