Energy Profile Installation Instructions

Similar documents
Touch Sensor 2 plus Installation Instructions

1 Safety instructions

1 Safety instructions. 2 Device components. Dimmer push-button/2-way low voltage. Order No. : Operating instructions

Power enhancement for the dimmers contained in the reference list (see section Technical

Operating Instructions Electronic transformers for lowvoltage halogen lamps

1 Safety instructions. 2 Intended use. 3 Product characteristics. 4 Operation. System Universal LED dimming insert Standard

Operating Instructions. Tronic Dimmer

Drive Unit e-drive1. Installation instructions 04/2014. English translation of the original German installation instructions

1 Safety instructions. 2 Device components. System Blind control insert with auxiliary input

Eazipole Cordless. Installation & Set Up Instructions. Electric Blinds & Curtains

Operating Instructions 2-channel pushbutton interface 4-channel pushbutton interface

NAPOLI WIRE PANELS. Epoxy-coated on galvanized core Ral 6005 green, Ral 9005 black or Ral 7016 anthracite Mesh 100 x 55 mm Wire Ø 3,8/4,0 mm. Art.

PRSalpha Air Drill (Double Valve)

System 2000 DRA automatic stairway lighting, Impulse insert. 1 Safety instructions. 2 Device components

ROOF. design: Laura Andreini

Installation manual ASTER AUTOMATION FOR SWING GATES 11_16

Installation Manual. AutoSteer. Gleaner Combine. AutoGuide 2 Steer Ready. Supported Models A66 A76 R66 R76 S67 S77 PN: A

lights and gypsum units from one source.

TECHNICAL MANUAL PERGOLAS

Consists of. Date:17/02/2011 Page 1/8

Drive unit. Installing/removing ebike components. Tool: Allen key size 8. ISIS crank-puller. Spider-Tool. Lever (e.g.

OSRAM GmbH Hellabrunner Str. 1 D Munich Tel.: +49 (0) Fax: +49 (0)

STAND FOOT - STAND TUBE

Mahindra Pikup (2009 Production Onwards)

H15P. Toyota Hilux A-DECK Dual Cab

Installation Guide Rollerdor RD55 Econ Roller Garage Door

1 Product Description System Layout Safety Instructions Intended Use Installation... 3

PROJECTOR LIFT MODEL SIH-300 INSTALLATION MANUAL

TESLA MODEL S REAR UNDER SPOILER & DIFFUSER SYSTEM

CONTENT VIPP LAMPS : TIMELESS ILLUMINATION 4-5 IMPORTANT SAFETY INSTRUCTIONS 6-8 VIPP521 TABLE LAMP VIPP522 WALL LAMP 16-23

2x 10W LED Slimline Floodlight Twin Flood

Installation Instructions : Ford Focus MK3 RS : Page 1 Tools Required: Philips screwdriver, trim removal tool, Torx, 10mm socket

Removing and installing trim panel

OFFICE PARTITIONS. Data Port Openings. Use cable tie bracket to dress data cables under panels. STEP 1

Audi S4 SMIC Installation. B5 Audi S4 Side Mount Intercooler installation

Linear Luminaire with LED

Rondelec Armoire de trottoir

DIGITAL NET. MULTI-BEAM OPTICAL BARRIER OPTICAL OR BY WIRE SYNCHRONISM COMPLETE DIGITAL CONTROL with AGC 10 1 METRE 2 STRAIGHT OR 4 CROSSED BEAMS

OPERATIONS MANUAL. Mini Centrifuge Model MCF Certified

Light Source Replacement

Assembling the Front Panel

1 Product Description Check of the supplied Parts Notes Intended Use Current Collector... 3

Standard. Industrial Storage Technology

STEEL Prisma Architectural Design

Multipole Conductor Rail MultiLine Program 0831

High-pressure switch for gas, air, flue gases and combustion products GW A4/2 HP

basic quattro No /

Ram 1500 Crew Cab A Ram 2500/3500 Crew Cab A

Eazidraw Cordless. Installation & Set Up Instructions. Electric Blinds & Curtains

KH E, KH E

EN Operating manual. Motorised zone valve. Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3


Assembly instructions. Veranda sunblind VZ510. art.nr

MEKO OPENER FOR RACK-DRIVEN SLIDING MOTOR

Siemens Drives & PLCs

I n s t a llat ion & O p e r atin g In s truc t ions

FLOODLIGHT unit IMPORTANT WARNING! RRAC055/RRAC059. INSTALL TIME: 30 mins

Aluminium sliding gate

RCA PLUG KIT P/N APPLICATION BEFORE YOU BEGIN KIT CONTENTS. Verify accessory fitment at Polaris.com.

Linear Luminaire for Fluorescent Lamps

INSTALLATION I N S T R U C T I O N S

Sectional and Tilting Door Opener

EASY GLASS MAX THE STRONGEST GLASS RAILING EVER

LB - LIGHTING BUSWAY 25-40A

SITRANS F Coriolis Flowmeters SITRANS FCS400 sensor Quick Start

Bow Extension Cylinders

ACROBAT SWING STAND MODEL

Mounting and Operating Instructions EB 5868/5869 EN

GPS AutoSteer System Installation Manual

Luxa. Wide range. Luxa has many options so it is suitable for any type of installation: Emergency light fittings

Getting started with

BMW E61 Hydraulic Pump replacement instructions

MODEL BA735QC. Instruction Manual. Qwik Change Extension Arm

Empty enclosures IEC 62208

varioflex 19 network & server cabinets, 600, 800 mm width - 600, 800, 1000 mm depth

A c c e s s o r i e s

E5 5 th Wheel Hitch Assembly

King Dome. user manual

Swing Piston Compressors and Vacuum Pumps

Pressure switch for gas, GW 500 A4 GW 500 A4/2

LED LIGHT BAR INSTRUCTION MANUAL 4WD ACCESSORIES W 2

The specialist for fastening technology. Post holders NEW. to our product range

INSTALLATION MANUAL SPECTRUM BRAKE CONTROL

NOTE: PERFORM THE PARKING BRAKE CABLE INSPECTION ON BOTH RIGHT AND LEFT REAR PARKING BRAKE CABLES.

INSTRUCTIONS FOR OUTDOOR WALL LANTERN, MODEL LPT-1032

I N S T A L L A T I O N G U I D E

GTK 80. Technical data

Installation manual. English. mystrike OPENER FOR RACK-DRIVEN SLIDING MOTOR

Energy Supply Systems

AIM LED LIGHT (wall mount)

1. Seat 6. Side cover 11. Fuel pump retainer. 4. Mud guard 9. Fuel pump gasket : Do not reuse.

CABINETS AND ENCLOSURES. XL³ 400 and XL³ 800 GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Standard. Manual Shopfitting and Storage Systems

High-pressure switch for gas, air, flue gases and combustion products GW A4/2 HP

Exchange of rollers from the XTS-Mover

LU27 Series Quick Start

Direct drive electronic position indicators

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

Please pay attention to all Cautions and Notes within these instructions.

MK7 GTI Electronic Folding Mirror Conversion

Transcription:

Order no.:1341 xx / 1347 xx with lighting element Order no.:1342 xx / 1348 xx Light Profile Order no.:1343 xx Light Profile, small Order no.:1344 xx Description The is made from painted aluminium and designed for outdoor use in domestic applications to provide electrical power and area or orientation lighting. Various types of connectors and switches can also be integrated into s, such as telephone and loudspeaker sockets or light switches. Gira s are available in four different models in the colours pure white, anthracite grey and aluminium: with three SCHUKO socket outlets Order no. 1341 26/27/28 with three socket outlets with earthing pin Order no. 1347 26/27/28 with a lighting element with empty unit and two SCHUKO socket outlets Order no. 1342 26/27/28 with empty unit and two socket outlets with earthing pin Order no. 1348 26/27/28 Light Profile (height: 769 mm) Order no. 1343 26/27/28 Small Light Profile (height: 491 mm) Order no. 1344 26/27/28 Construction The basic construction of an with lighting element is illustrated here: (1) top cover (2) lighting element with light panel (3) connection unit with TX_44 switch plate (4) profile (5) profile base 1/06 Page 1 of 7

1 2 i Maintenance instructions Please clean your using only soapy water or a solvent-free, non-foaming cleaning agent. 3 4 5 installation i Condensation opening Before installing the, open the condensation exit on the bottom of the profile base. To do so, break out the tab for the opening and remove any rough edges using a file. The can be fitted with just one screw. Depending on the conditions of the underlying surface, there are two different options for anchoring the to the ground. 1/06 Page 2 of 7

Using a soil tube 2. Feed the lead-in cables (i.e. power cables and telephone or loudspeaker cables) through the tube. 3. Fill the excavated hole with concrete and place the tube upright in the hole. 4. Feed the lead-in cables through the profile base. 5. Fasten the profile base to the tube using the provided hexalon-head screw. 6. Connect the wiring. 7. Connect the earth lead of the to the earth terminal on the profile base. 8. Place the on the profile base and fasten it in place using the three Allen screws. Positioning the soil tube When cementing the soil tube in place, bear in mind the desired position of the. The can be rotated around the axis of the soil tube by up to 20 degrees to adjust its orientation. Direct screw fitting On a firm underlying surface, such as brick, concrete or asphalt, the can be installed directly on the ground.. On loose or soft subsoil, such as a flower bed or lawn, install the using a soil tube. Please proceed as follows: 1. Dig a hole (of approximately 50 cm) at the location where you wish to install the profile. Please proceed as follows: 1. Drill a hole where you want to install the profile and insert the supplied plug. 2. Feed the lead-in cables (mains power cable and telephone or loudspeaker cable, if applicable) throu- 1/06 Page 3 of 7

gh the profile base. 3. Fasten the profile base to the ground using the provided hexagon-head screw. 4. Connect the. 5. Connect the earth wire of the to the earth terminal on the profile base. 6. Place the on the profile base and fasten it using the three Allen screws. Connecting the wiring Note! The installation and assembly of electrical equipment may only be performed by a qualified electrician. The 's lighting element and socket outlets are pre-wired up to the connection terminals. Proceed as follows to connect the to the mains circuit: 1. Remove the terminal box from the bottom opening of the and open it. 2. The connection of the terminals depends on the model. L N For s with connection unit, connect the power cable for the socket outlets to the L/N/ terminals. For s with a lighting element, the lighting is connected via the /N/ terminals. 3. The free and unlabeled terminals can be used for wiring the empty unit. 4. Close the terminal box and slide it back into the. 5. Connect the earth lead to the earth terminal on the profile base. Installing and replacing lamps A Compact fluorescent lamp with E27 socket is used in the as a light source. More information about suitable lamps can be found in the Specifications. In order to install or replace the lamp, please proceed as follows: 1. Remove the screws from the top cover and remove the top cover from the profile. 2. Pull the light panel upwards, sliding it out of the profile. 3. Place the lamp in the fitting. 4. Place the light panel by sliding it in the profile from the top (pay attention to 'TOP FRONT' indication). 5. Place the top cover and fasten with the screws. i Lamp diameter Compact fluorescent lamps with a base diameter of up to 52 mm can be used in the. If a slats element is used, the maximum base diameter is reduced to 48 mm! 1/06 Page 4 of 7

Installation of slats element An optional slats element can be used in order to focus the lighting element on objects or paths. To fit the slats element and the accompanying transparent light panel, please proceed as follows: 1. Remove the screws from the top cover and remove the top cover from the profile. 2. Pull the light panel upwards, sliding it out of the profile. 3. Place the transparent panel by sliding it in the profile from the top (pay attention to the 'TOP FRONT' indication). 4. Fit the slats element: with the slats directed upward for object lighting, for example. with the slats directed downward for path lighting, for example. 5. Place the top cover and fasten it with the screws. i Transparent panel / light panel The slats element can be used with either a transparent panel or a satinised light panel. Empty connection units s with lighting elements have one empty unit that can be individually fitted. This empty unit is provided with an intermediate plate and spring cover suitable for integrating System 55 base elements. 1/06 Page 5 of 7

1. 2. Please proceed as follows to fit a new base element: 1. Remove the Torx screws securing the threefold switch plate and remove the switch plate by inserting the tip of a screwdriver under the lower corner and levering up the switch plate. 2. Remove the intermediate plate with spring cover. 3. Using a screwdriver, prise the blind panel free of the empty unit. Remove the screws from the wall socket's base elements and remove the base elements. 4. Remove the frame base. 5. Replace the blind panel supporting ring with a new built-in base element. 6. Position the frame base. 7. Install the base elements and tighten with screws if necessary. 8. Fit the intermediate plates with spring cover. 9. Click the switch plate firmly into place and insert he Torx screws. i Integration of System 55 base elements Certain System 55 base elements require a different intermediate plate and spring cover from the TX_44 range. An overview of which base elements can be combined with which intermediate plates is provided in the Gira catalogue. 3. 1/06 Page 6 of 7

Specifications Dimensions (W x H x D): Profile base: 229 x 10 x 155 mm Small profile: 142 x 491 x 75 mm Large profile: 142 x 769 x 75 mm Protection: IP 44 with covers closed Connections: Screw clamps, 1 x 4 mm 2 or 2 x 2.5 mm 2 Lamp: Compact fluorescent lamp with E27 socket (TC-DSE, TC-TSE) Power: 21 W max. Socket diameter:52 mm max. 48 mm max. (if slats element is used) e.g.: RADIUM Ralux RX-Q, RX-QS. RX-E, OSRAM Dulux EL, PHILIPS PLE-L Lighting range Large Light Profile, satinised light panel, 20 W lamp. Small Light Profile, satinised light panel, 20 W lamp. i Caution: switch-on peak current When using observers or Automatic switches, please remember that compact fluorescent lamps have relatively high switch-on peak currents. Acceptance of guarantee We accept the guarantee in accordance with the corresponding legal provisions. Please return the unit postage paid to our central service department giving a brief description of the fault: Gira Giersiepen GmbH & Co. KG Service Center Dahlienstrasse 12 D-42477 Radevormwald The CE sign is a free trade sign addressed exclusively to the authorities and does not include any warranty of any properties. Gira Giersiepen GmbH & Co. KG Postfach 1220 D-42461 Radevormwald Telefon: +49 / 21 95 / 602-0 Telefax: +49 / 21 95 / 602-339 Internet: www.gira.de 1/06 Page 7 of 7