SERVO-DRIVE The opening support system for more freedom of motion for TANDEMBOX plus BLUMOTION www.blum.com
Our interpretation of perfect motion 2
Easy opening, silent and effortless closing SERVO-DRIVE is an electrical drive opening support system for drawers and pull-outs. By combining this feature with BLUMOTION, for silent and effortless closing action, we have created new levels of motion quality. Kitchen customers will be amazed by the ease of use, quality and freedom of motion. Contents 4 SERVO-DRIVE at a glance 5 Different applications 6 9 10 11 11 Standard cabinet with horzontal or vertical cross members Planning horizontal cross member Planning vertical cross member Assembly horizontal cross member Assembly vertical cross member 12 15 17 Larder unit Planning Assembly 1 21 22 Sink unit Planning Assembly 24 27 27 Cabinet with individual pull-out - Bracket profile horizontal Planning - Bracket profile horizontal Assembly - Bracket profile horizontal 2 31 31 Cabinet with individual pull-out - Upper attachment bracket Planning - Upper attachment bracket Assembly - Upper attachment bracket 34 37 37 3 3 40 42 44 Waste bin drawer Planning Assembly Information Applications assembly Blum transformer Cabling Drive unit 46 Order specification 3
SERVO-DRIVE at a glance Create more freedom of motion with SERVO-DRIVE SERVO-DRIVE is the new opening support system for drawers and pull-outs that we are certain will inspire your customers. A light touch on the front or a light pull of the handle, drawers and pull-outs will open effortlessly, regardless of where you touch the front. With the integrated BLUMOTION system, pull-outs will re-close silently and gracefully. Advantages for the kitchen users: Automatic opening with just a light touch or pull No fixed connection to the drive system Silent and effortless closing thanks to BLUMOTION SERVO-DRIVE won the red dot best of the best design award for its unique design. Everything at hand Whether heavy or light, wide or narrow pull-outs the gentle opening support always remains the same. SERVO-DRIVE users always have the final say as to when the drawer stops or closes. Whether handle-less or with handle: SERVO-DRIVE turns every kitchen into the place to be. Your customers will be inspired. 4
Different applications 5
Standard cabinet with horizontal or vertical cross members 6
7
Standard cabinet with horizontal or vertical cross member 2 3 5 1 10 4 9 6 7
Planning - Horizontal cross member Basic element "horizontal cross member" cabinet dimensions KB LW LT Cabinet width Inner cabinet width Internal cabinet depth NL X Y Runner system nominal length Drilling position Min. space requirement Drilling distance base/cross bar Using this assembly position for the bracket profile, both inner pull-out elements as well as those with overlay fronts can be opened by pushing and pulling. For this application situation, the following general dimensions apply: Space requirement and drilling position for all application situations Chipboard back X Y NL + 19 min LT = NL + 33 SERVO-DRIVE can also be used if there is less space available. At the assembly position below for the bracket profile, inner pull-out elements can only be opened by pulling (not by pushing). Min. space requirement and drilling position Chipboard back X Y NL + 16 min LT = NL + 30 Position of drive unit LH PL Internal cabinet height Profile length Related information Drilling Pattern base Front Assembly: Position of Blum distance bumper Bracket profile for cutting to size Cabling 3 3 3 42 9
Standard cabinet with horizontal or vertical cross member Planning - Vertical cross member Basic element "vertical cross member" cabinet dimensions KB LW LT Cabinet width Inner cabinet width Internal cabinet depth NL X Y Runner system nominal length Drilling position Min. space requirement Drilling distance base/cross bar Using this assembly position for the bracket profile, both inner pull-out elements as well as those with overlay fronts can be opened by pushing and pulling. For this application situation, the following general dimensions apply: Space requirement and drilling position for all application situations X Y Chipboard back NL + 19 LT = NL + 34 SERVO-DRIVE can also be used if there is less space available. At the assembly position below for the bracket profile, inner pull-out elements can only be opened by pulling (not by pushing). Min. space requirement and drilling position Chipboard back X Y NL + 16 LT = NL + 31 Related information Drilling Pattern base Front Assembly: Position of Blum distance bumper Bracket profile for cutting to size Cabling 3 3 3 42 10
Assembly - Horizontal cross member Attach bracket profile Horizontal cross member Related information Insert bracket profile and/or communications cable Install drive unit 39 44 Assembly - Vertical cross member Attach bracket profile Vertical cross member Related information Insert bracket profile and/or communications cable Install drive unit 39 44 11
Larder unit 12
13
Larder unit 2 3a 4 3 5 2 4 3 5 2 6 7 14
Planning - Upper bracket profile with vertical cross member "Upper bracket profile" larder unit Drilling distance base/cross bar NL LT Runner system nominal length Internal cabinet depth Using this assembly position for the bracket profile, both inner pull-out elements as well as those with overlay fronts can be opened by pushing and pulling. For this application situation, the following general dimensions apply: X Y NL + 19 LT = NL + 34 X Y Drilling position Min. space requirement SERVO-DRIVE can also be used if there is less space available. At the assembly position below for the bracket profile, inner pull-out elements can only be opened by pulling (not by pushing). Chipboard back X Y NL + 16 LT = NL + 31 Planning - Lower bracket profile with horizontal cross member Lower bracket profile larder unit Drilling distance base/cross bar NL LT Runner system nominal length Internal cabinet depth Using this assembly position for the bracket profile, both inner pull-out elements as well as those with overlay fronts can be opened by pushing and pulling. For this application situation, the following general dimensions apply: Chipboard back SERVO-DRIVE can also be used if there is less space available. At the assembly position below for the bracket profile, inner pull-out elements can only be opened by pulling (not by pushing). X NL + 19 Y min LT = NL + 33 X Drilling position X Y Y Min. space requirement Chipboard back NL + 16 min LT = NL + 30 15
Larder unit Planning Position of drive unit All back heights except N LH PL Internal cabinet height Profile length Related information Drilling Pattern base Front Assembly: Position of Blum distance bumper Bracket profile for cutting to size 3 3 3 16
Assembly Install bracket profile attachment Attach upper bracket profile 17
Sink unit 1
19
Sink unit 13 5 11 9 14 15 5 1 6 7 20
Planning Basic element (1) Cross member position (1) (2) Cabinet width 900 mm and higher (1) Space requirements in cabinet Attachment bracket 1 tier Cross member (1) Cross member drilling pattern Attachment bracket 1 tier Plan view: * measured from cabinet front edge Chipboard back Chipboard back X 176.5 Drilling depth mm (2) Base drilling pattern Attachment bracket 2 tier Alternative: Drilling pattern for MINIPRESS and PRO-CENTER Related information Cabling 42 Basic element (2) Space requirements in cabinet Attachment bracket 2 tier Base (1) Steel back * measured from cabinet front edge Chipboard back (2) 21
Sink unit Planning (2) Drilling distances base Cabinet width 900 mm and higher Using this assembly position for the attachment bracket, both inner pull-out elements as well as those with overlay fronts can be opened by pushing and pulling. For this application situation, the following general dimensions apply: Space requirement and drilling position for all application situations Chipboard back X NL + 19 min LT = NL + 33 Y SERVO-DRIVE can also be used if there is less space available. At the assembly position below for the attachment bracket, inner pull-out elements can only be opened by pulling (not by pushing). Min. space requirement and drilling position Chipboard back X NL + 16 min LT = NL + 30 Y LT Internal cabinet depth X Drilling position NL Runner system nominal length Y Min. space requirement Related information Front assembly: Position of Blum distance bumper 3 22
Assembly Sink cabinet Drive unit Attachment bracket 2 tier A 2nd drive unit can also be installed (optional). Attachment bracket 1 tier Related information Installation of drive unit to attachment bracket 44 23
Cabinet with individual pull-out element Bracket profile horizontal 24
25
Cabinet with individual pull-out element Bracket profile horizontal 16 5 16a 17 1 16 6 7 26
Planning - Bracket profile horizontal Space requirements in cabinet Using this assembly position for the bracket profile, both inner pull-out elements as well as those with overlay fronts can be opened by pushing and pulling. For this application situation, the following general dimensions apply: Space requirement and drilling position for all application situations Chipboard back X NL - 9 Y min LT = NL + 37 * 55.5 for back height N SERVO-DRIVE can also be used if there is less space available. At the assembly position below for the bracket profile, inner pull-out elements can only be opened by pulling (not by pushing). ** 23.5 for back height N Chipboard screws and system screws can be used Min. space requirement and drilling position X Chipboard back NL - 12 Y min LT = NL + 34 NL Runner system nominal length LT Internal cabinet depth Related information X Y Drilling position Min. space requirement Cabling Front Assembly: Position of Blum distance bumper Bracket profile for cutting to size 42 3 3 Bracket profile for cutting to size Position of the drive unit on the bracket profile Cutting dimensions for the bracket profile horizontal LW Internal width Assembly - Bracket profile horizontal Install bracket profile attachment Install bracket profile horizontal in bracket profile attachment Chipboard screws and system screws can be used 27
Cabinet with individual pull-out element - Upper attachment bracket 2
29
Cabinet with individual pull-out element Upper attachment bracket 1 5 1 6 7 30
Planning - Upper attachment bracket Space requirements in cabinet Using this assembly position for the upper attachment bracket, both inner pull-out elements as well as those with overlay fronts can be opened by pushing and pulling. For this application situation, the following general dimensions apply: Space requirement and drilling position for all application situations X Y Chipboard back NL - 1 min LT = NL + 33.5 SERVO-DRIVE can also be used if there is less space available. At the assembly position below for the upper attachment bracket, inner pull-out elements can only be opened by pulling (not by pushing). X Y Min. space requirement and drilling position Chipboard back NL - 4 min LT = NL + 30.5 NL LT X Y Runner system nominal length Internal cabinet depth Drilling position Min. space requirement Related information Front Assembly: Position of Blum distance bumper Cabling 3 42 31
Cabinet with individual pull-out element Planning - Upper attachment bracket Position of drive unit Assembly - Upper attachment bracket Run cable Screw on attachment bracket 32
Assembly - Upper attachment bracket Install drive unit to adapter 33
Waste bin drawer 34
35
SERVO-DRIVE set for the waste bin drawer 13 1 9 11 5 15 36
Planning (1) Space requirements in cabinet Attachment bracket 1 tier (2) Drilling distances base Chipboard back Cabinet width 900 mm and higher (2) Base drilling pattern Attachment bracket 2 tier Using this assembly position for the attachment bracket, both inner pull-out elements as well as those with overlay fronts can be opened by pushing and pulling. For this application situation, the following general dimensions apply: Space requirement and drilling position for all application situations X Y Chipboard back NL + 19 min LT = NL + 33 SERVO-DRIVE can also be used if there is less space available. At the assembly position below for the attachment bracket, inner pull-out elements can only be opened by pulling (not by pushing). Min. space requirement and drilling position Chipboard back X Y NL + 16 min LT = NL + 30 LT Internal cabinet depth X Drilling position NL Runner system nominal length Y Min. space requirement Alternative: Drilling pattern for MINIPRESS and PRO-CENTER Related information Front assembly: Position of Blum distance bumper Cabling 3 42 Assembly Refer to Sink cabinet - Drive unit Installation of drive unit to attachment bracket 23 44 37
Information - Application planning Applicable to all applications except Larder unit Front assembly: Position of Blum distance bumper The Blum distance bumper creates and maintains the required trigger path of 2 mm. When using a 65 kg runner, always attach 4 Blum distance bumpers. Use front stabilisation for optimal triggering for front heights > 300 mm. FA FH Front overlay Front height Applicable to Standard cabinet with horizontal or vertical cross members Drilling pattern base Bracket profile for cutting to size Lower cabling Back cabling Alternative: Drilling pattern for MINIPRESS and PRO-CENTER PL = LH - 10 mm LH PL Internal cabinet height Profile length Related information Cabling xx 3
Information - Application assembly Applicable to Standard cabinet with horizontal or vertical cross members Insert bracket profile cable and/or communications cable into the bracket profile Equip bracket profile Bracket profile with both cables 1 bracket profile cable (for power supply) 2 communications cables 39
Information - Blum transformer Two types of fixing Base fixing Wall fixing 10 10 9 12 7 11 6 6 7 Assembly Transformer unit housing for base fixing Pull-out stop Transformer unit housing for wall fixing Pull-out stop 40
Information - Blum transformer Recommended distance Space requirement + safety distance for transformer unit housing Note: Maintain a 30 mm safety distance from the bottom edge (base fixing) and/or front edge (wall fixing) and side edges of transformer unit housing to the neighbouring elements to allow for air circulation; otherwise, there is a risk that the Blum transformer could overheat. Base fixing Wall fixing Removal Blum transformer removal - Base fixing Blum transformer removal - Wall fixing 41
Information - Cabling Only 1 Blum transformer can be connected to each distribution cable Standard cabinet lower cabling cable diagram Larder unit cable diagram 5 9 13 5 9 10 10 11 6 7 6 7 5 Transformer unit housing for base fixing Transformer unit housing for wall fixing Standard cabinet back cabling cable diagram 7 13 6 5 9 5 10 9 13 7 6 7 11 6 Transformer unit housing for base fixing Transformer unit housing for wall fixing Lower cabling Back cabling Do not damage piercing tips 42
Information - Cabling Only 1 Blum transformer can be connected to each distribution cable Sink pull-out cable diagram Lower cabling 5 5 9 13 5 5 11 13 10 7 7 6 9 6 Transformer unit housing for base fixing Transformer unit housing for wall fixing Bracket profile horizontal cable diagram Lower cabling 7 6 Upper attachment bracket cable diagram Lower cabling 7 6 Connecting node assembly Do not damage piercing tips 43
Information - Drive unit Installation Drive unit installation Drive unit adjustment Selector switch Mode (1) Multiple: when set to Multiple, drive units move simultaneously Single: only one drive unit moves (default setting) Selector switch Power (2) Half: for short nominal lengths (270 300 mm) pull-out only moves a short distance Full: default setting Operating mode display (LED) (3) Drive unit selector switches Lever extension The drive unit comes with the lever extension. The lever extension must be removed for a cabinet width of 300 320 mm in combination with a steel back and for a cabinet width up to 300 mm in combination with a chipboard back. Removal Assembly Lever guide The lever guidance must be attached and secured with screws for cabinet widths 275 320 mm if being used with a chipboard back. Synchronisation cable 44
Information - Drive unit Removal Drive unit removal from bracket profile Drive unit removal from attachment bracket Drive unit removal from bracket profile horizontal Drive unit removal from upper attachment bracket 45
Order specification Distance bumper Article No. Description Transformer unit housing Article No. Assembly type 993.030.01 Ø mm Z10NG000 Base fixing Bracket profile Article No. Description Z10NG100 Wall fixing Z10D01E2.01 Z10T1170A Upper attachment Excluding cable length: 1170 mm Synchronisation cable Article No. Description Z10K120S For synchronisation of 2 drive units Flex cord Article No. Size Z10D01E1 Lower attachment Z10M200B Length: 2 m Drive unit Article No. Z10A3000.01 Lever guide Article No. Z10A3H00 Colour Dust grey Description For cabinet widths 275-320 mm in combination with a chipboard back Connecting node Article No. Description Attachment bracket 1 tier Article No. Description For individual Z10D7101 drawers with 1 drive unit Attachment bracket 2 tier Article No. Description Z10D7201 For heavy drawers with 2 drive units Bracket profile for individual pull-out Article No. Description Z10D5210 Left/ and right Z10V1000 To be pierced into the cable Z10D5210 Adapter for bracket profile horizontal Cable end protector Article No. Material Z10K000 Distribution cable Article No. Description Z10K600A Nylon For cutting to size Length: 6 m Blum transformer Article No. Description Z10NE050.01 100 watt Bracket profile horizontal Article No. Description Z10T1143B For cabinet widths 275-1.200 mm Upper attachment bracket Article No. Description With pre-mounted Z10D6252 adapter for the drive unit Cable clip Article No. Z10K0009 Description Self-adhesive 46
47
Blum Fittings For the lifetime of your kitchen Blum South East Asia Pte. Ltd. 150 Ubi Avenue 4 #02-00 Ubi Biz-Hub Singapore 4025 Tel.: (65) 6547 1760 Fax: (65) 6547 1761 Email: info.sg@blum.com 4