Models CMXC-SB, PMXC-SB, and WMXC Series Installation Manual for Optional Fixture Mounts

Similar documents
Commander Rotating Light Models and 371L-120 Installation and Maintenance Manual

model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

BMRX Series ROTARY LEVEL CONTROL

AIR CHAMP PRODUCTS. User Manual. Sheave & Pilot Mount Clutch-Brake Model BCB-275 FORM NO. L F-0414 FORM NO. L F-0414

HR-20P Pneumatically Controlled Pressure Regulator

SPC Series. Digital Scale. Operation Manual

Electrostatic Fieldmeter

FADE Series Wall Axial Fans

MaxLite LED Linear HighBay Fixtures

INSTRUCTIONS SMOKE BLOWER WITH HONDA ENGINE PART NUMBER

2000 Series Flameproof Xenon and Fluorescent Beacons Installation and Service Instructions

UniTorq UTQ Quarter-Turn Actuator Installation and Operation Manual

30100 Module Installation Guide L

HATCHGRIP Installation Instructions/Operation and Maintenance Manual

HP190SL Series Slimline Radon Fans

(L 70 ) 3000K / 4000K / 5000K 12 50,000 50, K / 4000K / 5000K 15 50, K / 4000K / 5000K 18 50,000

AIR CHAMP PRODUCTS. User Manual. BW Clutch or Brake Sheave, Pilot and Coupling Mount FORM NO. L U-1209 FORM NO.

OPERATOR S MANUAL with Parts List & Warranty. For Model 100SP Topdresser

15100 Module Installation Guide Mercedes EPA07 w/dpf

Open Display Merchandiser Installation and Operation Manual Please read this manual completely before attempting to install or operate this equipment!

Installation / Operation Instructions Sunnex ORION Series Exam Lights

CBC-160-1N and CBC-160-2N Clutch/Brake Controls

Mercedes MBE 906/ L & 7.2L Engine Module. Part # Installation Instructions

BMRX Series Rotary Level Indicator

ROLLER GRILL Instruction Manual Model #8223, 8224, Part No Revised:March 2008

INSTALLATION AND SERVICE INSTRUCTIONS FOR 2000 SERIES FLAMEPROOF XENON AND FLUORESCENT BEACONS

DeZURIK AFR3 Filter Regulator Used on Pneumatic Cylinder Actuators

MaxLite LED Enclosed & Sealed Jelly Jars

Installation & Operation Manual. Electrak 100 Series / Electromechanical Linear Actuator

Type Flexair Pneumatic Pressure Control Valves

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY

OPERATING INSTRUCTIONS PLEASE READ CAREFULLY

Installation Instructions

430B SERIES HORIZONTAL SPLIT CASE PUMP

20250 Module Installation Guide

INSTALLATION/OWNER'S MANUAL DP " Woofer in Enclosure

5 BBL Hybrid Brewhouse

Parts Manual Vermeer/ McLaughlin Mud System 230P

STAINLESS STEEL FORGED FITTINGS 3000lb 304/304L & 316/316L Forged Stainless Steel Fittings Product Specifications

Installation Instructions

Installation Instructions

Manufacturing Facility is ISO9001:2000. Welded Steel Pipe Conform to ASTM A53. Threads Conform to ASME B1.20.1

Power. On Your Terms.

VERTICAL AND HORIZONTAL SPLIT CASE FIRE PUMPS

A48 / A48B (base plate) BATTERY CHARGER

FR1118- P10. User s Manual

DWS404 DWS524 DWS654 DWS684 DWS694. DWS SERIES INSTALLATION/OWNER'S MANUAL Car Audio Speakers

Four-Position Gang Charger for SAFEMTX Li-ION Battery Packs

Parts Manual Vermeer/ McLaughlin Mud System 230P

GM 6.6L Duramax. Up to 90HP Gain. AgDieselSolutions.com

MaxLite LED UTILITY WRAP FIXTURES

Hot Dog Roller Grills Instruction Manual Model #8023, Model #8024 and Model #8025 Model #8023SL, Model #8024SL and Model #8025SL

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH

8" - 12" Hydraulic Steel Squeeze Off Tool

Model 90 Twin Control Unit

Warranty Information North America

DeZURIK 2-24 (50-600mm) KGN-RSB BI-DIRECTIONAL CAST STAINLESS STEEL KNIFE GATE VALVES

1000-LB. MOTORCYCLE LIFT TABLE OWNER S MANUAL

TABLE OF CONTENTS GENERAL SPECIFICATIONS... 3 SAFETY SUMMARY INTRODUCTION INSTALLATION Location and Mounting Input

10 Year Limited Warranty

JD2800 Module Installation Guide

Linear Actuator. Installation Manual. warranty installation parts list. Linear Actuator Installation Manual Page 1

INSTALLATION & OPERATING INSTRUCTIONS: REVOLUTION SPINEBOARD ATTACHMENT WARNING

Electric Pilot System

AIR CHAMP PRODUCTS. User Manual. DAP-625S and DAP-875S FORM NO. L D-0914

Cummins N14 Celect & Celect Plus Engine Module. For Agricultural Applications Only. Part # 31200

Operation and Maintenance Manual for Multipurpose Actuators. 120 VAC Actuator 12 VDC Actuator 12 VDC Actuator

Gen 2 Electrically Released Motor Brake Module for EM-MBFB and EUM-MBFB

Cincinnati, OH USA

Stainless Steel Pilot Piston Solenoid Valve 2MS Series for High Temperature & High Pressure

Installation Instructions

User Manual Breeze Revision 01.2 September 2018 Tempest Lighting, Inc.

Battery Charger Retrofit Kit Q-DCCHG1 for DC Cabinet Retrofit Manual

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

DUSTTRAK AEROSOL MONITOR SOLAR POWER KIT MODEL

INSTRUCTION MANUAL FOR PC63 CAGE

AT Clutch Major Service Sizes 25, 55, 115

DeZURIK KUL KNIFE GATE VALVES

Installation Instructions. Application List Dodge 24V PLEASE READ ALL INSTRUCTIONS BEFORE INSTALLATION

Installation Instructions

Installation Manual Stand-Alone Dispenser Pan Sensor

Installation Guide Document N Cleanroom Mirrors Copyright 2016 Terra Universal Inc. All rights reserved. Revised November 2016

DeZURIK 2 20" BOS BUTTERFLY VALVES

1800,1900 MODELS VERTICAL AND HORIZONTAL SPLIT CASE FIRE PUMPS

Spare Parts, Instruction and Maintenance Manual for SPANCO Model 301 Jib Cranes

Female Plug. connecting to Fuel Quantity

DeZURIK 2-24 (50-600mm) KGC ES or HD KNIFE GATE VALVES

HBC-20 - LED HIGH BAY

Emergency Response Trailer 14

CU6703 Module Installation Guide

Warner Electric UNIBRAKE Motor Brakes

Accu-Meter Oil Pump. Instruction Manual. Model #2114. Cincinnati, OH USA. Part No Revised June 1996

INSTALLATION AND MAINTENANCE MANUAL FORM #PM-126 REV A 12/09

Operating Instructions for PAC800 Battery Charger

AIR CHAMP PRODUCTS. FCB-450, LCB-600, MCB-800 Clutch-Brakes FORM NO. L F-0914

Color Wheel Instruction Manual Model #7767

OPERATOR S AND PARTS MANUAL PALLET FORKS. Part Number: MODEL NUMBER: Rev. 4

REDI-LINE. Rugged, Reliable, DC to AC Power Conversion ELECTRIC GENERATORS USER'S GUIDE. KARAM A.L.

Manual Transfer Switch

900 SERIES SPLIT CASE FIRE PUMP REPAIR PARTS INDEX

Transcription:

Models CMXC-SB, PMXC-SB, and WMXC Series Installation Manual for Optional Fixture Mounts 25500050A REV. A 413 Printed in U.S.A.

Warranty Seller warrants all goods for five years on parts and 2-1/2 years on labor, under the following conditions and exceptions: Seller warrants that all goods of Seller's manufacture will conform to any descriptions thereof for specifications which are expressly made a part of this sales contract and at the time of sale by Seller such goods shall be commercially free from defects in material or workmanship. Seller reserves the right at the Seller s discretion to Repair and Return or Replace any item deemed defective during the warranty period. This warranty does not cover travel expenses, the cost of specialized equipment for gaining access to the product, or labor charges for removal and reinstallation of the product. This warranty shall be ineffective and shall not apply to goods that have been subjected to misuse, neglect, accident, damage, improper maintenance, or to goods altered or repaired by anyone other than Seller or its authorized representative, or if five years have elapsed from the date of shipment of the goods by Seller with the following exceptions: lamps and strobe tubes are not covered under this warranty. Outdoor warning sirens and controllers manufactured by Federal Warning Systems are warranteed for two years on parts and one year on labor. No agent, employee, representative or distributor of Seller has any authority to bind the Seller to any representation, affirmation, or warranty concerning the goods and any such representation, affirmation or warranty shall not be deemed to have become a part of the basics of the sales contract and shall be unenforceable. THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES OR MERCHANTABILITY, FITNESS FOR PURPOSE AND OF ANY OTHER TYPE, WHETHER EXPRESS OR IMPLIED. These warranties shall not apply unless Seller shall be given reasonable opportunity to investigate all claims for allegedly defective goods. Upon Seller's instruction a sample only of allegedly defective goods shall be returned to Seller for its inspection and approval. The basis of all claims for alleged defects in the goods not discoverable upon reasonable inspection thereof pursuant to paragraph 8 hereof must be fully explained in writing and received by Seller within thirty days after Buyer learns of the defect or such claim shall be deemed waived. Industrial Systems 2645 Federal Signal Drive University Park, IL 60484-3167 Tel: +1 708-534-4756 +1 877 289 3246 Fax: 708-534-4852 Email: elp@federalsignal.com www.federalsignal-indust.com

Contents Safety Messages to Installers... 5 Overview of the Fixture Mounts... 6 Installing the CMXC-SB Ceiling Mount... 6 Installing the PMXC-SB Pendant Mount... 7 Wiring the DC Beacon to the CMXC-SB and PMXC-SB... 8 Wiring the AC Beacon to the CMXC-SB and PMXC-SB... 9 Installing the WMXC-Series Wall Mount... 10 Wiring the Non-supervised DC Beacon to the WMXC-SB... 10 Wiring the Supervised DC Beacon to the WMXC-4 and WMXC-4R 11 Connecting the AC Beacon to the WMXC-SB... 12 Figures Figure 1 Model CMXC-SB ceiling mount...6 Figure 2 Model PMXC-SB pendant mount...7 Figure 3 Model WMXC-SB wall mount...10 3

4 2013 Federal Signal Corporation

Safety Messages to Installers It is important to follow all instructions shipped with this product. This device is to be installed by a trained electrician who is thoroughly familiar with the National Electric Code/Canadian Electric Code and will follow the NEC/CEC Guidelines as well as local codes. The selection of mounting location for the device, its controls and the routing of the wiring is to be accomplished under the direction of the facilities engineer and the safety engineer. In addition, listed below are some other important safety instructions and precautions you should follow: Read and understand all instructions before installing or operating this equipment. Never alter the unit in any manner. Safety in hazardous locations may be endangered if additional openings or other alterations are made in units specifically designed for use in these locations. After installation, ensure that all screws are properly tightened. After installation, test the light system to ensure that it is operating properly. After testing is complete, provide a copy of this instruction sheet to all operating personnel. Establish a procedure to routinely check the light installation for integrity and proper operation. Failure to follow all safety precautions and instructions may result in property damage, serious injury, or death. 5

Overview of the Fixture Mounts The optional fixture mounts are designed to replace the original pendant mount on the explosion-proof light housing. Wiring must comply with Article 500 of the National Electrical Code and the local authority having jurisdiction. For Marine applications, all wiring, including supply wire, must be stranded wire and meet USCG (CFR46) Sections (110-113.) Installing the CMXC-SB Ceiling Mount To install the ceiling mount on the support surface: 1. See Figure 1. Secure the ceiling mount to the support surface using the four external mounting slots. 2. Remove the terminal block from the ceiling mount by removing the two screws securing it to the fixture. 3. For instructions on wiring the beacon, see page 8 for the DC beacon or page 9 for the AC beacon. Figure 1 Model CMXC-SB ceiling mount THE CMXC-SB IS NOT SUITABLE FOR USE WITH THROUGH-BRANCH CIRCUIT CONDUCTORS. EXTERNAL MOUNTING SLOTS (4) CLOSE-UP PLUG TERMINAL- BLOCK SCREW (2) TERMINAL BLOCK 290A7243 6

Installing the PMXC-SB Pendant Mount To install the pendant mount on 3/4-inch pipe: 1. Ensure that the mating threads are clean. 2. Thread the pendant mount onto the 3/4-inch pipe and secure it with the setscrew. 3. Remove the terminal block from the ceiling mount by removing the two screws securing it to the fixture. 4. For instructions on wiring the beacon, see page 8 for the DC beacon or page 9 for the AC beacon. Figure 2 Model PMXC-SB pendant mount TERMINAL BLOCK TERMINAL BLOCK SCREW (2) 7

Wiring the DC Beacon to the CMXC-SB and PMXC-SB The CMXC-SB is not suitable for use with through-branch circuit conductors. SHOCK HAZARD To avoid electrical shock hazards, do not connect the light to the supply circuit when power is applied. REVERSE POLARITY/MISWIRING DC strobe units are polarity- and voltage-sensitive and may be damaged by an incorrect electrical hookup. When connecting the 24 Vdc strobe unit to the voltage supply lines, polarity must be observed. In addition, damage will result if the voltage rating of the particular model is exceeded. See the figures on pages 6 and 7. To wire the DC beacon to the fixture terminal block: 1. Connect the positive (+) power source wire to the terminal block screw marked L+. 2. Connect the negative ( ) power source wire to the terminal block screw marked N. 3. If required by local building codes, connect the earth ground wire to the green screw in the fixture mount. 4. Place the terminal block in the fixture mount and secure it with the mounting screws. 5. Plug unused conduit entries with the provided close-up plugs. 6. To prevent galling and ease future maintenance, ensure that the fixture mount threads are clean and lubricated. 7. Thread the fixture clockwise into the fixture mount and hand tighten it securely. 8

Wiring the AC Beacon to the CMXC-SB and PMXC-SB The CMXC-SB is not suitable for use with through-branch circuit conductors. SHOCK HAZARD To avoid electrical shock hazards, do not connect the light to the supply circuit when power is applied. To reduce shock hazards during maintenance POLARITY MUST BE OBSERVED when connecting AC units to the power source. See the figures on pages 6 and 7. To wire the AC beacon to the fixture terminal block: 1. Connect the phase (hot) power source wire to the terminal block screw marked L+. 2. Connect the common (neutral) power source wire to the terminal block screw marked N. 3. If required by local building codes, connect the earth ground wire to the green screw in the fixture mount. 4. Place the terminal block in the fixture mount and secure it with the mounting screws. 5. Plug unused conduit entries with the provided close-up plugs. 6. To prevent galling and ease future maintenance, ensure that the threads on the fixture mount are clean and lubricated. 7. Thread the fixture clockwise into the fixture mount and hand tighten it securely. 9

Installing the WMXC-Series Wall Mount To install the wall mount fixture on the support surface: 1. See Figure 3. Secure the wall mount to the support surface using the two external mounting holes. 2. Use wire nuts to connect power and ground as described in the next sections. Figure 3 Model WMXC-SB wall mount INSPECTION HOLE CLOSE-UP PLUG Wiring the Non-supervised DC Beacon to the WMXC-SB SHOCK HAZARD To avoid electrical shock hazards, do not connect the light to the supply circuit when power is applied. REVERSE POLARITY/MISWIRING DC strobe units are polarity- and voltage-sensitive and may be damaged by an incorrect electrical hookup. When connecting the 24 Vdc strobe unit to the voltage supply lines, polarity must be observed. In addition, damage will result if the voltage rating of the particular model is exceeded. 10

To wire the non-supervised DC beacon to the fixture terminal block: 1. Connect the positive (+) power source to the black wire. 2. Connect the negative ( ) power source to the white wire. 3. If required by local building codes, connect the green/yellow wire to earth ground. 4. To prevent galling and ease future maintenance, ensure that the fixture mount threads are clean and lubricated. 5. Thread the fixture clockwise into the fixture mount and hand tighten it securely. Wiring the Supervised DC Beacon to the WMXC-4 and WMXC-4R SHOCK HAZARD To avoid electrical shock hazards, do not connect the light to the supply circuit when power is applied. REVERSE POLARITY/MISWIRING DC strobe units are polarity- and voltage-sensitive and may be damaged by an incorrect electrical hookup. When connecting the 24 Vdc strobe unit to the voltage supply lines, polarity must be observed. In addition, damage will result if the voltage rating of the particular model is exceeded. The Models WMXC-4 and WMCX-4R wall mounts have five leads: two red, two black, and one green/yellow. To wire the supervised DC beacon to the fixture terminal block for electrical supervision: 1. Connect one red (+) lead to the positive side of the incoming power source. 2. Connect the other red (+) lead to the positive side of the outgoing power source. 11

3. Connect one black ( ) lead to the negative side of the incoming power source. 4. Connect the other black ( ) lead to the negative side of the outgoing power source. 5. If required by local building codes, connect the green/yellow lead to earth ground. 6. To prevent galling and ease future maintenance, ensure that the fixture mount threads are clean and lubricated. 7. Thread the fixture clockwise into the fixture mount and hand tighten it securely. Connecting the AC Beacon to the WMXC-SB SHOCK HAZARD To avoid electrical shock hazards, do not connect the light to the supply circuit when power is applied. To reduce shock hazards during maintenance POLARITY MUST BE OBSERVED when connecting AC units to the power source. See Figure 3 on page 10. To wire the AC beacon to the fixture terminal block: 1. Connect the phase (hot) power source wire to the black wire. 2. Connect the common (neutral) power source to the white wire. 3. If required by local building codes, connect the earth ground wire to the green/yellow wire. 4. Push the wires into the inspection hole Plug unused conduit openings and the inspection hole with the provided close-up plugs. 5. To prevent galling and ease future maintenance, ensure that the fixture mount threads are clean and lubricated. 6. Thread the fixture clockwise into the fixture mount and hand tighten it securely. 12