Models ADMAG AXF and ADMAG CA Sanitary 3A Compliant Integral and Remote Magnetic Flowmeters

Similar documents
Models ADMAG AXF and ADMAG CA Sanitary 3A Compliant Integral and Remote Magnetic Flowmeters

EGM5300C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

ISTEC MAGNETIC METERS

Abridged Specifications: 10D1477 Electrodeless Sensor with 50XM1000 Transmitter

PMG MAGNETIC FLOWMETER

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet

EGM1100C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

Electromagnetic Flowmeters. Product Overview.

RCM - Direct Reading Flowmeters

Magnetic Inductive Flowmeter EP / UMF2 (B)

Smart Electromagnetic Flowmeter Detector for Sanitary use

Detector (for water measurement applications)

OM004, OM006 & OM008 Oval Gear Meter

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

SHENITECH, LLC

User s Manual. Model MLD Loop Powered Process Indicator IM 61A01A01-01E-A IM 61A01A01-01E-A. 4th Edition

MagneW Neo+ Two-wire Electromagnetic Flowmeter Integral type TIIS Explosion-protected Apparatus

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

F-2700 SERIES INSERTION VORTEX FLOW METER

General Specifications

EPS / UMF2. Magnetic Inductive Flowmeter for Conductive Liquids

F-2600 SERIES INLINE VORTEX FLOW METER

F6700 ELECTROMAGNETIC METER

User's Manual Models SE100MJ/NJ and SE200MJ/NJ Integral Type Magnetic Flowmeter

Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids

imag 4700 SERIES FLANGED MAGMETER

Electro-Magnetic Flowmeters Sensors MagMaster MFE

The Polaris MA1 is the first liquid flow meter offered by Magnetrol, expanding the already diverse level and flow measurement portfolio that has been

User s Manual. Model MLA & MLD Loop Powered Process Indicators. Model MLD (Digital) Model MLA (Analog)

Appendix. Clearance. Skewed profiles. Application Schematics

Electromagnetic Flowmeter for Partially-filled Pipes

FIELD DEVICES - FLOW PSS 1-6F9 A. Product Specifications

F-2700 SERIES INSERTION VORTEX FLOW METER

F-1500 SERIES INSERTION TURBINE FLOW METER

Hydro-Flow 2200 Fixed Insertion Vortex Flow Meter

유량계전문제조업체. Electro Magnetic FLOWMETER

Rosemount 8750WB Magnetic Flowmeter System

G2 Industrial Grade Meters

ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products Rev PK KMS501W & KMS502F- TW. Electromagnetic TRADEWASTE Flowmeters FEATURES:

F-2500 SERIES VORTEX METER

Full Profile Insertion

Field IT Electro-Magnetic Flowmeters Sensors

Instruction Manual. Model SC4A 19mm Conductivity Sensors. IM 12D7J4-E-E 6th edition YOKOGAWA

UL6300 SONICMAX. Ultrasonic Clamp-on Flowmeter OUTLINE FEATURES STANDARD SPECIFICATION. Common specification

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951)

HG5 Series. Metal Tube Rotameter CATALOG MAIN FEATURES TECHNICAL PARAMETERS

Digital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series. Bulletin 01F06A02-00E.

Water Solutions For Global Needs

ABB Instrumentation. MagMaster MFE Series Electromagnetic Sensors. Specifications. MagMaster - bringing unsurpassed flowmetering performance

EM101 LOW FLOW MAGNETIC FLOWMETER INSTRUCTIONS

Product Data Sheet 2012 Rev 5 FLOWMETRIX SA SAFMAG Electromagnetic Flowmeter Doc Date

F-2600 SERIES INLINE VORTEX FLOW METER

Electromagnetic flowmeter EMKO E

OM SERIES OVAL GEAR METERS. OM SERIES Oval Gear Meters

User s Manual. AXF Series Magnetic Flowmeter Installation Manual IM 01E20A01-01EN IM 01E20A01-01EN. Contents

OMP POSITIVE DISPLACEMENT FLOWMETERS

Vortex Flowmeter. digitalyewflo. Vortex Flowmeter. Series. Bulletin 01F06A02-00E.

Level Sensor with G1/2" Thread Hygienic

Level Sensor with M12 Thread Hygienic

Electromagnetic Flow Meter Owner s Manual HARDWARE

PanaFlow MV80. In-line Multivariable Flowmeter for Mass, Temperature, and Pressure. GE Sensing. Applications. Key Benefits

... PureLine PQ. Technical Specification. PureLine PQ (Disinfection) Models PQ PQ UV Chamber. Cabinet

Instructions EM 101 Low Flow Electromagnetic Flow Meters

MASSMAX 1000 Series Straight twin tube Coriolis Mass Flowmeter

DW PADDLE-BELLOWS FLOWMETER & SWITCH

UniMag DT Series Electromagnetic Flow Tubes

Hydro-Flow Model 2200 Fixed Insertion Vortex Flowmeter Installation and Operation Manual

SITRANS F M flow sensors 711/A and 711/911E

Magnetic-Inductive Flow Meter FMI

RCM. Direct Reading Flowmeter. for Liquids or Gases

Hydro-Flow Model 3100 Retractable Insertion Vortex Flowmeter Installation and Operation Manual

OMP Positive Displacement Flowmeters

Electronic pressure transmitter with gauge display Rotatable display with numeric indication

DW PADDLE-BELLOWS FLOWMETER & SWITCH

Micro Motion T-Series Straight-Tube Mass Flow and Density Meters. Product Data Sheet PS July 2001

Continuous level sensor NSK

SITRANS F M. Flow sensor MAG 1100 F 3/59

General Specifications

OPTIFLUX 6000 Technical Datasheet

Dosimag. Technical Information. Electromagnetic volume flow measuring system for filling applications

Technical Information

VIM20 Vortex Insertion Flowmeter

RTD Elements c/w tails.

Magnetic Inductive Flow

Digital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series

Flow Measurement SITRANS F M

QUALITY INDUSTRIAL FLOWMETERS

Magnetic-Inductive flow Meter fmi

E M F. Description. Principle of Operation. Introduction for EMF Series of Electromagnetic Flowmeters

Hydro-Flow Model 3100

DW PADDLE-BELLOWS FLOWMETER & SWITCH

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

Product Data Sheet , Rev GA Catalog Content

OPTISWITCH 4000/5000. Vibration level switches for liquids

Coriolis Flow Solutions for a Global Marketplace

Multivariable Vortex Flow Meter

Flow Measurement SITRANS F M

VersaFlow Mag 3000 Electromagnetic Flow Sensor Technical Datasheet. Specification

2100 Turbine Flow Sensor

Ultrasonic Flowmeter. M-1500 Plus Non-invasive Inline DSP Ultrasonic Flowmeter. Operating Principle. Features

Transcription:

General Specifications Models and ADMAG CA Sanitary 3A Compliant Integral and Remote Magnetic Flowmeters ADMAG and ADMAG CA 3A & FDA compliant magnetic flowmeters are dependable and reliable instruments designed to meet strict sanitary requirements. The entire ADMAG family of flowmeters is capable of measuring a wide range of fluids. All meters provide a 4-20 ma DC signal and a pulse or alarm output. 3A & FDA compliance is available in both PFA and ceramic lined meters, making the meters applicable for numerous applications. Yokogawa Corporation of America offers 3A compliant meters with butt weld and Triclamp connections. Additional features and detailed specifications of each individual model can be found in the General Specification sheets referred to below. FEATURES Available with BRAIN or HART communication function. Available for use with AC or DC power supply. Multifunctional microprocessor-based electronics. Available with accuracy to 0.35% of reading. 3A & FDA compliant ceramic flowmeters with Tri-clamp fittings. 3A & FDA compliant PFA flowmeters with Tri-clamp or butt weld process connections. Ceramic liners finished to a 20 µ inch Ra or better polish. Dual frequency excitation. Available with integral or remote-mounted electronics. Multiple outputs: 4-20 ma, pulse, alarm or status control. ADMAG CA 3A & FDA compliant ceramic flowmeter with Tri-clamp fittings. 99.9% Alumina Ceramic liners manufactured to a finish of less than 20 µ inch Ra. Ultra-low conductivity measurement to 0.01 µs/cm Non-wetted electrodes eliminate electrode leakage and electrode fouling: i.e. slurry noise Multiple outputs: 4-20 ma, pulse, or alarm & ADMAG CA SELECTION GUIDE Features and Functions ADMAG ADMAG AXF Integral Electronics A A Remote Electronics A N PFA liner w/tri-clamp connections A N Ceramic liner with Tri-Clamp Connections A A Explosionproof N A Status Contact Input A N Status and Alarm Contacts A N Empty Pipe Detection A N A: Available N: Not Available CA Electrodeless Design N A HART Communication A N BRAIN communication A A Fluid conductivity < 1µS/cm N A Yokogawa Corporation of America 2 Dart Road, Newnan, GA 30265-1040, USA Phone 770.253.7000 Fax 770.254.0928 URL: www.yokogawa.com/us 7th edition, March 2013

2 STANDARD SPECIFICATIONS FLOW TUBE PFA lined with Tri-clamp or butt weld end connections (Sizes 1-4 ) Non-wetted parts material Flow tube housing: 304 stainless steel Terminal box/converter housing: Aluminum alloy Wetted parts material Liner: PFA Teflon Electrodes: 316L stainless steel* Gasket: EPDM rubber Adapter (Tri-clamp/butt weld): 316L stainless steel* * Polished to a finish of 20 µinch Ra or better Ceramic-lined with Tri-clamp connections (Sizes 0.2-4 ) Non-wetted parts material Flow tube housing: SUS329 stainless steel Terminal box/converter housing: Aluminum alloy Wetted parts material Liner: Polished alumina ceramic (99.9%)* Electrode: Platinum-alumina cermet Gasket: FDA compliant PTFE Adapter (Tri-clamp): 316 stainless steel* * Polished to a finish of 20 µinch Ra or better Refer to document GS 01E20D01-01E-A for detailed product specifications MAGNETIC FLOW CONVERTERS Model AXFA14 (integral or remote) Model AXFA11 (remote only) Output Signal Current output: 4-20 madc (load resistance 0-750 ohms) Pulse/Alarm or status: Transistor contact output rated 30 VDC, 200 ma) Status Contact Output Functions (software selectable) Multi-ranging Forward and reverse flow measurement Totalization switch 0% signal lock Flow upper/lower limit alarms Instantaneous Flow Rate/Totalizer Display Three line LCD indicator with backlit, full dot matrix display Infrared switches permit programming through the glass Communication BRAIN or HART communication signal superimposed on the 4-20 madc signal Electrical Connection ANSI 1/2 NPT female Protection IP67, NEMA 4X Mounting AXFA14: 2 pipe AXFA11: 2 pipe, panel or surface mounting Size inch (mm) 0.2 (5) 0.4 (10) 0.5 (15) 1.0 (25) 1.5 (40) 2.0 (50) 3.0 (80) 4.0 (100) Adjustable Range in Min 0 to 0.03 0 to 0.13 0 to 0.20 0 to 0.80 0 to 1.8 0 to 3.21 0 to 7.23 0 to 12.85 GPM Max 0 to 3 0 to 12 0 to 28 0 to 77 0 to 198 0 to 311 0 to 796 0 to 1244 Refer to documents GS 01E20C02-01E-A (AXFA14) and GS 01E20C01-01E-A (AXFA11) for detailed product specifications ADMAG CA FLOW TUBE Adjustable Range in Min 0 to 0.007 0 to 0.03 0 to 0.06 0 to 0.18 0 to 0.45 0 to 0.71 0 to 1.81 0 to 2.83 m 3 /h Ceramic lined with Tri-clamp connections (Sizes 0.5-4 ) Non-wetted parts material Flow tube housing: 304 stainless steel Terminal box/converter housing: Aluminum alloy Wetted parts material Liner: Polished alumina ceramic (99.9%)* Gasket: FDA compliant PTFE Adapter (Tri-clamp): 316 stainless steel* Max 0 to 0.7 0 to 3 0 to 6 0 to 18 0 to 45 0 to 71 0 to 181 0 to 283 Electrode construction Electrode plates mounted outside the ceramic metering tube (non-wetted) * Polished to a finish of 20 minch Ra or better

3 ADMAG CA MAGNETIC FLOW CONVERTER (integral mount only) Output Signal Current output: 4-20 madc (load resistance 0 to 750 ohms) Pulse/Alarm: Transistor contact output (contact rating 30 VDC, 200mA) Instantaneous Flow Rate Display Functions Seven-digit backlit LCD displays flow rate in engineering units or percent of span Totalizer Display Functions Totalized volume in any engineering unit can be displayed by setting a totalizing factor Wiring Connection ANSI 1/2 14 NPT female Construction General purpose and FM/CSA approved types: NEMA 4X, watertight and corrosion resistant HOW TO ORDER 1. Refer to the selection guide above and select the desired model ( or ADMAG CA) that meets your application requirements. 2. Refer to the appropriate general specification sheet for your model (see STANDARD SPECIFICATIONS section above) and build the base model number. 3. Complete the model number by adding the correct suffix code, when applicable, as shown below. Ceramic lined flowtube with Tri-clamp connection: Suffix Code: /YF268 ADMAG CA Ceramic lined with Tri-clamp connection: Suffix Code: /YF268 Refer to document GS 01E08B01-00E for detailed product specifications Size inch (mm) 0.5 (15) 1.0 (25) 1.5 (40) 2.0 (50) 3.0 (80) 4.0 (100) Adjustable Range in GPM Min Max 0 to 1 0 to 28 0 to 4 0 to 77 0 to 9 0 to 198 0 to 16 0 to 311 0 to 36 0 to 796 0 to 64 0 to 1244 Adjustable Range in m 3 /h Min Max 0 to 0.3 0 to 6 0 to 0.9 0 to 18 0 to 2.3 0 to 45 0 to 3.5 0 to 71 0 to 9.1 0 to 181 0 to 14.1 0 to 283

4 PFA lined with Tri-clamp connection (1.0"-4") Integral and remote style

5 PFA lined with butt weld connection (1.0"-4") Integral and remote style

6 Ceramic lined with Tri-clamp connection (0.2" and 0.4") Integral and remote style Suffix code: /YF268 Unit : mm (approx. inch) 3(0.12) Tri-clamp not shown in this view Dimensions A/B/C/D are in mm (in) FLOWMETER SIZE A DIA B DIA C DIA D DIA F CLAMP SIZE 0.2" 8 (0.31) 7.74 (0.30) 22.0 (0.87) 18.75 (0.74) 9.40 (0.37) 0.4" 9.4 (0.37) 9.40 (0.37) 25.0 (0.98) 22.5 (0.89) 3/4" 15.75 (0.62) 22.10 (0.87)

7 Model Remote flowtube Integral flowmeter Remote flowtube Integral flowmeter Size code Size Lining code Face-to-face length Ceramic lined with Tri-clamp connection (0.5") Integral and remote style Suffix code: /YF268 015 15(0.5) C 193.3(7.6) Height H1 144(5.67) Max. Height Hr 268(10.55) Max. Height 0 L -3 *2 Outside dia. ød 44(1.73) Hi 306(12.03) 49(1.93) Hi 73(2.87) 154(6.06) Hr 70(2.76) H1 Ground Terminal (M4) ø86(3.38) 48 (1.89) L 3(0.12) Unit : mm (approx. inch) Integral Flowmeter Remote Flowtube 197(7.76)* 1 Ground Terminal (M4) 66* 1 51.5 51.5 28(1.1) (2.6) (2.03) (2.03) 111(4.37) ø128(5.04) 4- ø6.2(0.24) ød (ød) 72 (2.83) 58 (2.28) F26.EPS *1: When indicator code N is selected, subtract 12 mm (0.47 inch) from the value in the figure. Tri-clamp not shown in this view METER SIZE "I" TUBE SIZE "F" TRICLAMP "L" ADAPTER LENGTH "X" TRANSITION "B" BORE I.D. "R" RATING "FD" "FT" THICKNES "BC" BOLT CIRCLE "N" NUMBER OF HOLES "H" HOLE "G" STEP 1/2" 3/4" 0.984" 2.25" 0.590" 0.825" ANSI 1/2"-150# 3.50" 0.38" 2.38" 4 0.62" 1.32"

8 Ceramic lined with Tri-clamp connection (1-4") Integral and remote style Suffix Code: /YF268 Model Size code Size Lining code Integral Flowmeter 154(6.06) Remote Flowtube Ground Terminal (M4) ø Unit : mm (approx. inch) Integral Flowmeter Remote Flowtube Ground Terminal (M4) 197(7.76)* 2 * 1 51.5 28(1.1) 111(4.37) Remote flowtube Integral flowmeter Face-to-face length Outside dia. Height L ød H1 Hi 128(5.04) H1 Remote flowtube Max. Height Hr Integral flowmeter Max. Height Hi *1: When indicator code N is selected, subtract 12 mm (0.47 inch) from the value in the figure. L Tri-clamp not shown in this view F27.EPS METER SIZE CA "I" TUBE SIZE "F" TRICLAMP "L" ADAPTER LENGTH "X" TRANSITION "B" BORE I.D. "R" RATING "FD" "FT" THICKNES "BC" BOLT CIRCLE "N" NUMBER OF HOLES "H" HOLE "G" STEP 1" 1" 1.984" 2.25" 0.984" 0.870" ANSI 1" - 150# 4.25" 0.50" 3.12" 4 0.62" 1.99" 1-1/2" 1-1/2" 1.984" 2.25" 1.575" 1.370" ANSI 1-1/2" - 150# 5.00" 0.63" 3.88" 4 0.62" 2.70" 2" 2" 2.516" 2.50" 2.047" 1.870" ANSI 2" - 150# 6.00" 0.69" 4.75" 4 0.75" 3.25" 3" 3" 3.579" 2.5-" 3.189" 2.870" ANSI 3" - 150# 7.50" 0.88" 6.00" 4 0.75" 4.41" 4" 4" 4.682" 2.50" 3.858" 3.834" ANSI 4" - 150# 9.00" 0.88" 7.50" 8 0.75" 5.28"

ADMAG CA Ceramic lined with Tri-clamp connection (1/2") Integral version only Suffix Code: /YF268 9 METER SIZE CA "I" TUBE SIZE "F" TRICLAMP "L" ADAPTER LENGTH "X" TRANSITION "B" BORE I.D. "R" RATING "FD" "FT" THICKNES "BC" BOLT CIRCLE "N" NUMBER OF HOLES "H" HOLE "G" STEP 1/2" 3/4" 0.984" 2.25" 0.590" 0.825" ANSI 1/2"-150# 3.50" 0.38" 2.38" 4 0.62" 1.32"

10 ADMAG CA Ceramic lined with Tri-clamp (1-4 ) Integral version only Suffix Code: /YF268 METER SIZE CA "I" TUBE SIZE "F" TRICLAMP "L" ADAPTER LENGTH "X" TRANSITION "B" BORE I.D. "R" RATING "FD" "FT" THICKNES "BC" BOLT CIRCLE "N" NUMBER OF HOLES "H" HOLE "G" STEP 1" 1" 1.984" 2.25" 0.984" 0.870" ANSI 1" - 150# 4.25" 0.50" 3.12" 4 0.62" 1.99" 1-1/2" 1-1/2" 1.984" 2.25" 1.575" 1.370" ANSI 1-1/2" - 150# 5.00" 0.63" 3.88" 4 0.62" 2.70" 2" 2" 2.516" 2.50" 2.047" 1.870" ANSI 2" - 150# 6.00" 0.69" 4.75" 4 0.75" 3.25" 3" 3" 3.579" 2.5-" 3.189" 2.870" ANSI 3" - 150# 7.50" 0.88" 6.00" 4 0.75" 4.41" 4" 4" 4.682" 2.50" 3.858" 3.834" ANSI 4" - 150# 9.00" 0.88" 7.50" 8 0.75" 5.28"