GEMÜ 539 esydrive Motorized globe valve

Similar documents
GEMÜ 549 esydrive Motorized globe valve

GEMÜ 649 esydrive Motorized diaphragm valve

Globe Control Valve, Metal

Globe Valve, Metal. Sectional view

Angle Seat Globe Control Valve, Metal

Angle Seat Globe Control Valve, Metal

Angle Seat Globe Control Valve, Metal

Globe Valve, Metal. Sectional drawing

GEMÜ R680 Motorized diaphragm valve

Angle Seat Globe Control Valve, Metal

GEMÜ 205 Electrically operated solenoid valve

Angle Seat Globe Valve, Metal

Angle Seat Globe Valve, Metal

Diaphragm Valve, Metal

710, 717, 723. Ball Valve, Plastic

Control Valve, Metal. Options Versions according to ATEX for manual and pneumatic operation on request

Angle Seat Globe Valve, Metal

Diaphragm Valve, Metal

Diaphragm Valve, Metal

600, 630. Diaphragm Valve, Plastic

R690. Diaphragm Valve, Plastic

Diaphragm Valve, Plastic

Diaphragm Valve, Metal

550 Connection code 80 / Valve body material code C2. Angle Seat Globe Valve, Metal

N086, N186, N786. Pressure retaining valve, Plastic

653, 654. Diaphragm Valve, Metal

R677. Diaphragm Valve, Plastic

611, 671. Diaphragm Valve, Metal

611, 671. Diaphragm Valve, Metal

Diaphragm Valve, Metal

Diaphragm Valve, Metal

Butterfly Valve, Metal

Intelligent Positioner

Diaphragm Valve, Plastic

Diaphragm Valve, Plastic

555 Connection code 80 / Valve body material code C2. Angle Seat Globe Valve, Metal Aseptic

Diaphragm Valve, Plastic

SilverLine S647, S660, S670. Diaphragm Valves, Plastic/Metal

Diaphragm Valve, Metal

Diaphragm Valve, Metal

Diaphragm valve, Plastic

Diaphragm Valve, Metal

Control Valve, Plastic/Metal

Diaphragm Valve, Plastic

650TL. Diaphragm Valve, Metal. Special version "TL"

410, 417, 423. Butterfly valve, Plastic

Control valve BioStar control

Intelligent Positioner

Full Bore Diaphragm Valve, Metal

790, 791, 797, 798. Ball valve, metal

Diaphragm Valve, Metal

K715, 711, 728, 751. Ball Valve, Stainless steel

650TL. Diaphragm Valve, Metal. Special version "TL"

Diaphragm Valve, Plastic 2/2 way, motorized

Flowmeter, Plastic 805 / 807 / 815 / / 825 / 832 / 835. Sectional drawing

Butterfly valve, Metal

Solenoid Valve, Plastic

GEMÜ 710 Pneumatically operated ball valve

/ 855 / 857 / 861 / / 870 / 875 / 880 / 885. Variable Area Flowmeter, Plastic

Intelligent Positioner

Flowmeter, Plastic 855 / 857 / 865 / / 875 / 880 / 885

Diaphragm Valve, Plastic

Tank Bottom Valve, Metal

Butterfly valves Plastic and Metal

CATALOG. 2/2 - Way Angle Seat Valves SMART IN FLOW CONTROL.

GEMÜ 717 Manually operated ball valve

Flow-rate curves for diaphragm valves Type 2730 plastic, 2731 forged, 2731 cast, 2731 GP cold formed pipe valve body

Angle Seat Globe Valve, Metal

2/2-way Globe Control Valve with stainless steel design for media up to +185ºC, DN

Ball Valve, Metal - Sanitary

2/2-way Quarter-Turn Ball Valve in stainless steel with pneumatic rotary actuator, DN 10-50

Globe Valve System for continuous control. Type 8802/2301 electro-pneumatically operated globe valve + = TWO YEAR WARRANTY on this valve system

2/2-way ball valve with electric rotary actuator, ball valve in plastic, DN 10-50

2/2 way Globe Control Valve, threaded connection, 3/8" 3"

2/2-way ball valve with electric rotary actuator, ball valve in plastic, DN 10-50

0322, 0324, Pilot Solenoid Valve, Plastic

2/2-way Globe Valve for media up to +180 C, DN

2/2-way Globe Control Valve, threaded port connection, DN 10-65

2/2 way Globe Control Valve, flange connection, 1/2" 4"

Butterfly valves Plastic and Metal

BR 10a Control and Shut-off Butterfly valve

2/2-way Angle-Seat Valve for medium up to +180 C, threaded port connection, DN 15-65

ARI-STEVI 450 / 451 (DN15-150) Control valve - 3-way-form (mixing/diverting valve) (optional with screwed seat ring)

ARI-STEVI 450 / 451 Pneumatic actuator ARI-DP 32-34T. Electric actuator ARI-PREMIO 2,2-25 kn ARI-PREMIO-Plus 2G 2,2-25 kn

ARI-STEVI 450 / 451 (DN15-150) Control valve - 3-way-form (mixing/diverting valve) (optional with screwed seat ring)

ARI-STEVI 448 / 449 (DN15-100) Control valve in straightway form with screwed seat ring With pneumatic and electric actuators

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

ARI-STEVI 423 / 463 Pneumatic actuator ARI-DP 34-34T. Electric actuator ARI-PREMIO 5-25 kn ARI-PREMIO-Plus 2G 5-25 kn

2/2-way Angle-Seat Control Valve with stainless steel design for media up to +185ºC, DN15-65

ARI-STEVI 423 / 463 (DN ) Control valve - 3-way-form (mixing/diverting valve) (optional with screwed seat ring)

Electromotive process valve - 2-way angle-seat control valve

with pneumatic actuator Pneumatic process valve, Y-pattern DN ARI-STEVI AS 350 Pneumatic actuator - with screwed sockets

Data Sheet T EN

Electromotive process valve 2-way globe control valve

2/2-way ball valve with electric rotary actuator, ball valve in stainless steel, DN 10-65

ARI-STEVI 470 / 471 (DN15-150)

2/2-way Angle Seat Valve, manually operated, for media up to +180 C

Electromotive process valve - 2-way globe control valve

2/2-way Diaphragm Valve with stainless steel design, weld end or clamp connection, DN 8-25

ARI-STEVI 440 / 441 DVGW type approval

Transcription:

esydrive Motorized globe valve Features Linear or modified equal-percentage control characteristics High flow rates Force and speed are variably adjustable Extensive diagnostic facilities Operable via web interface esy-web Integral optical position indicator and LED high visibility display Standard gland packing suitable for vacuum up to 20 mbar (abs.) Description The 2/2-way globe valve has a hollow shaft actuator and is electrically operated. The esydrive hollow shaft actuator can be operated as an OPEN/CLOSE actuator or as an actuator with integrated positioner or process controller. The valve spindle is sealed by a self-adjusting gland packing providing low maintenance and reliable valve spindle sealing even after a long service life. A wiper ring fitted in front of the gland packing protects the seal against contamination and damage. An integral optical and electrical position indicator is standard. Technical specifications Nominal sizes: DN 40 to 100 Media temperature: -10 to 180 C* Ambient temperature: -10 to 60 C Operating pressure: 0 to 20 bar* Connections: Flange Valve body materials: 1.4408 EN-GJS-400-18-LT *depending on version and/or operating parameters further information webcode: GW-539

Availability Availability Availability of valve bodies Connection code 1) Material DN 40 DN 50 DN 65 DN 80 DN 100 code 2) 8 37 - X X X X 90 X X X X X 10 37 X - - - - 11 37 - - - - - 39 37 X X X X X 90 X X X X X 48 37 X X - - - 1) Connection Code 8: Flanges EN 1092, PN 16, form B, length EN 558 series 1, ISO 5752, basic series 1 Code 10: Flanges EN 1092, PN 25, form B, length EN 558 series 1, ISO 5752, basic series 1 Code 11: Flanges EN 1092, PN 40, form B, length EN 558 series 1, ISO 5752, basic series 1 Code 39: Flanges ANSI Class 125/150 RF, length EN 558 series 1, ISO 5752, basic series 1 Code 48: Flanges JIS 20K, length EN 558 series 10, ASME/ANSI B16.10 table 1, column 16, DN 50 drilled to JIS 10K 2) Valve body material Code 37: 1.4408, investment casting Code 90: EN-GJS-400-18-LT (GGG 40.3) 2 / 18

Product description Product description Kv value diagram Kv-Werte [%] 100 90 80 70 60 50 40 30 20 10 linear Kv-Werte [%] 100 90 80 70 60 50 40 30 20 10 gleichprozentig modifiziert 0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100 Hub [%] Hub [%] The adjacent diagram shows the approximative curve of the Kv value characteristic. The characteristic may deviate depending on valve body, nominal size, regulating cone and valve stroke. Regulating cone/regulating cage Regulating cone Regulating cage Regulating cone DN 40-50 Regulating cage DN 65-100 3 / 18

Order data Order data Order codes The order data provide an overview of standard configurations. Please check the availability before ordering. Other configurations available on request. 1 Type Code Globe valve, electrically operated, electro-mechanical hollow shaft actuator, esydrive 539 2 DN Code DN 40 40 DN 50 50 DN 65 65 DN 80 80 DN 100 100 3 Body configuration Code 2/2-way body 4 Connection Code Flanges EN 1092, PN 16, form B, length EN 558 series 1, ISO 5752, basic series 1 Flanges EN 1092, PN 25, form B, length EN 558 series 1, ISO 5752, basic series 1 Flanges EN 1092, PN 40, form B, length EN 558 series 1, ISO 5752, basic series 1 Flanges ANSI Class 125/150 RF, length EN 558 series 1, ISO 5752, basic series 1 Flanges JIS 20K, length EN 558 series 10, ASME/ANSI B16.10 table 1, column 16, DN 50 drilled to JIS 10K D 8 10 11 39 48 5 Valve body material Code 1.4408, investment casting 37 EN-GJS-400-18-LT (GGG 40.3) 90 6 Seat seal Code PTFE 5 PTFE, glass reinforced 5G 7 Voltage/frequency Code 24 V DC C1 8 Control module Code OPEN/CLOSE, positioner and process controller 9 Regulating cone Code Please find the number of the regulating cone (R- No.) for the linear or equal-percentage modified regulating cone in the Kv value table. L0 R. 10 Actuator version Code Actuator size 2 2 A Order example Order option Code Description 1 Type 539 Globe valve, electrically operated, electro-mechanical hollow shaft actuator, esydrive 2 DN 40 DN 40 3 Body configuration D 2/2-way body 4 Connection 10 Flanges EN 1092, PN 25, form B, length EN 558 series 1, ISO 5752, basic series 1 4 / 18

Order data Order option Code Description 5 Valve body material 37 1.4408, investment casting 6 Seat seal 5 PTFE 7 Voltage/frequency C1 24 V DC 8 Control module L0 OPEN/CLOSE, positioner and process controller 9 Regulating cone RS916 60 m³/h - mod.eq 10 Actuator version 2 A Actuator size 2 5 / 18

Technical data Technical data Medium Working medium: Max. permissible viscosity: Corrosive, inert, gaseous and liquid media which have no negative impact on the physical and chemical properties of the body and seal material. 600 mm²/s (cst) Other versions for lower/higher temperatures and higher viscosities on request. Temperature Media temperature: -10 to 180 C Ambient temperature: -10 to 60 C Pressure Operating pressure Other ambient temperatures on request DN 40 DN 50 DN 65 DN 80 DN 100 0-20 0-20 0-12 0-8 0-4 Pressures in bar All pressures are gauge pressures. Higher operating pressures on request Leakage rate Open-closed valve Seat seal Standard Test procedure Leakage rate Test medium Metal DIN EN 12266-1 P12 F Air PTFE, FPM, EPDM DIN EN 12266-1 P12 A Air Control valve Seat seal Standard Test procedure Leakage class Test medium Metal DIN EN 60534-4 1 IV Air PTFE, FPM, EPDM DIN EN 60534-4 1 VI Air 6 / 18

Technical data Kv values Open-closed valve Connection code 1) Material code 2) DN 40 8, 10, 11, 39, 48 37 35 50 90 127 200 DN 50 DN 65 DN 80 DN 100 Kv values in m³/h Kv values determined in accordance with DIN EN 60534. The Kv value specifications refer to the largest actuator for the respective nominal size. The Kv values for other product configurations (e.g. other connections or body materials) may differ. 1) Connection Code 8: Flanges EN 1092, PN 16, form B, length EN 558 series 1, ISO 5752, basic series 1 Code 10: Flanges EN 1092, PN 25, form B, length EN 558 series 1, ISO 5752, basic series 1 Code 11: Flanges EN 1092, PN 40, form B, length EN 558 series 1, ISO 5752, basic series 1 Code 39: Flanges ANSI Class 125/150 RF, length EN 558 series 1, ISO 5752, basic series 1 Code 48: Flanges JIS 20K, length EN 558 series 10, ASME/ANSI B16.10 table 1, column 16, DN 50 drilled to JIS 10K 2) Valve body material Code 37: 1.4408, investment casting Control valve Nominal size Kv value Actuator size Linear Equal-percentage Kv values in m³/h DN 40 25.0 2 A RS784 RS794 DN 50 40.0 2 A RS785 RS795 DN 65 80.0 2 A - RS796 DN 80 100.0 2 A - RS798 DN 100 160.0 2 A - RS799 Mechanical data Protection class: IP 65 acc. to EN 60529 Actuator weight: Operating time: Actuator size 2A 9.5 kg Adjustable, max. 4 mm/s 7 / 18

Technical data Electrical data Supply voltage Actuator size 2 Voltage Uv = 24 V DC ± 10% Current consumption Max. 5 A Rating 120 W Duty cycle Continuous duty Reverse battery protection Yes Analogue input signals Set value Input signal: Input type: Input resistance: Accuracy/linearity: Temperature drift: Resolution: Reverse battery protection: Overload proof: 0/4 20 ma/0 5/10 V DC (selectable using software) Passive 250 Ω ±0.3% of full flow ±0.1%/10 K 12 bit No Yes (up to ± 24 V DC) Process actual value Input signal: Input type: Input resistance: Accuracy/linearity: Temperature drift: Resolution: Reverse battery protection: Overload proof: 0/4 20 ma/0 5/10 V DC (selectable using software) Passive 250 Ω ±0.3% of full flow ±0.1%/10 K 12 bit No Yes (up to ± 24 V DC) 8 / 18

Technical data Digital input signals Digital inputs: 3 Function: Voltage: Logic level "1": Logic level "2": Input current: Can be selected via software 24 V DC >14 V DC < 8 V DC Typically 2.5 ma DC (at 24 V DC) Analogue output signals Actual value Output signal: Output type: Accuracy: Temperature drift: Load resistor: Resolution: Overload proof: Short-circuit proof: 0/4 20 ma/0 5/10 V DC (selectable using software) Active (AD5412) ±1% of full flow ±0.1%/10 K 750 Ω 10 bit Yes (up to ± 24 V DC) Yes Digital output signals Switching outputs 1 and 2 Version: Switch rating: 2x SPDT potential-free 125 V AC / 2 A 48 V DC / 2 A Switch points: Adjustable 0 100% Switching output 3 Function: Type of contact: Switching voltage: Switching current: Drop voltage: Overload proof: Short-circuit proof: Pull down resistance: Signal fault Push-Pull Supply voltage 0.1 A Max. 2.5 V DC at 0.1 A Yes (up to ± 24 V DC) Yes 120 kω Communication Interface: Function: IP address: Subnet screen: Ethernet Parametrisation via web browser 192.168.2.1 alterable via web browser 255.255.252.0 alterable via web browser 9 / 18

Technical data The actuator and the PC must be in the same network to use the web server. The IP address of the actuator is entered in the web browser and the actuator can then be parametrised. In order to use more than one actuator, a definitive IP address must be assigned to each actuator in the same network. Electrical connections Connection X1 7-pin plug, Binder, type 693 5 6 1 4 3 2 Pin Signal name Pin 1 Uv, 24 V DC supply voltage Pin 2 Uv GND Pin 3 Relay output K1, common Pin 4 Relay output K1, make contact Pin 5 Relay output K2, common Pin 6 Relay output K2, make contact Pin PE Function earth Connection X2 5-pin M12 built-in socket, D-coded 2 1 5 3 4 Pin Signal name Pin 1 Tx + (Ethernet) Pin 2 Rx + (Ethernet) Pin 3 Tx - (Ethernet) Pin 4 Rx - (Ethernet) Pin 5 Shield Connection X3 8-pin M12 plug, A-coded 10 / 18

Technical data 2 3 4 8 5 1 7 6 Pin Signal name Pin 1 I + set value input Pin 2 I set value input Pin 3 I + actual value output Pin 4 GND (actual value output, digital input 1 3, error message output) Pin 5 Error message output 24 V DC Pin 6 Digital input 1 Pin 7 Digital input 3 Pin 8 Digital input 2 Connection X4 4-pin M12 built-in socket, A-coded 1 2 4 3 Pin Signal name Pin 1 UV, 24 V DC actual value supply Pin 2 n. c. Pin 3 X -, process actual value input Pin 4 X+, process actual value input Pin 5 n. c. Product compliance Foodstuff Regulation (EC) No. 1935/2004* Regulation (EC) No. 10/2011* FDA* *depending on version and/or operating parameters European Union Pressure Equipment Directive: Machinery Directive 2006/42/EC EMC Directive 2014/30/EC 11 / 18

Dimensions Dimensions Actuator dimensions B1 B2 ØB A1 CT B3 SW 1 DN 40 DN 50 DN 65 DN 80 DN 100 A1 121,0 121,0 121,0 121,0 121,0 øb 129,0 129,0 129,0 129,0 129,0 B1 157,0 157,0 157,0 157,0 157,0 B2 224,0 224,0 224,0 224,0 224,0 B3 304,0 304,0 304,0 304,0 304,0 SW1 60,0 55,0 75,0 75,0 75,0 CT 471,0 479,0 502,0 522,0 543,0 Dimensions in mm 12 / 18

Dimensions Body dimensions Flanges DN 40-50 L k D FTF Connection Material DN 40 DN 50 code 2) code 1) FTF 8 37-230,0 90 200,0 230,0 10, 11 37 200,0-39 37, 90 200,0 230,0 48 37 165,0 203,0 ød 8 37-165,0 90 150,0 165,0 10, 11 37 150,0-39 37, 90 125,0 150,0 48 37 140,0 155,0 øk 8 37-125,0 90 110,0 125,0 10, 11 37 110,0-39 37, 90 98,4 120,7 48 37 105,0 120,0 øl 8 37-18,0 90 18,0 18,0 10, 11 37 18,0-39 37, 90 15,9 19,0 48 37 19,0 19,0 1) Connection Code 8: Flanges EN 1092, PN 16, form B, length EN 558 series 1, ISO 5752, basic series 1 Code 10: Flanges EN 1092, PN 25, form B, length EN 558 series 1, ISO 5752, basic series 1 Code 11: Flanges EN 1092, PN 40, form B, length EN 558 series 1, ISO 5752, basic series 1 Code 39: Flanges ANSI Class 125/150 RF, length EN 558 series 1, ISO 5752, basic series 1 Code 48: Flanges JIS 20K, length EN 558 series 10, ASME/ANSI B16.10 table 1, column 16, DN 50 drilled to JIS 10K 2) Valve body material Code 37: 1.4408, investment casting Code 90: EN-GJS-400-18-LT (GGG 40.3) Dimensions in mm 13 / 18

Dimensions Flanges DN 65-100 K D L FTF Connection Material DN 65 DN 80 DN 100 code 2) code 1) FTF 8, 39 37, 90 290,0 310,0 350,0 ød 8 185,0 200,0 220,0 39 180,0 190,0 230,0 øk 8 145,0 160,0 180,0 39 139,7 152,4 190,5 øl 8 18,0 18,0 18,0 39 19,0 19,0 19,0 Dimensions in mm 1) Connection Code 8: Flanges EN 1092, PN 16, form B, length EN 558 series 1, ISO 5752, basic series 1 Code 39: Flanges ANSI Class 125/150 RF, length EN 558 series 1, ISO 5752, basic series 1 2) Valve body material Code 37: 1.4408, investment casting Code 90: EN-GJS-400-18-LT (GGG 40.3) 14 / 18

Accessories Accessories GEMÜ 1218 GEMÜ 1218 is a connector (cable socket/cable plug), 7-pin. Straight and/or 90 angled plug type. Various materials available for the fixing nut. Ordering information Connection X1 supply voltage, relay outputs GEMÜ 1218 Binder connector Binder plug Mating connector for 468/ esydrive Terminal compartment/ screws, 7-pin Terminal compartment/ screws, 7-pin, 90 88220649 88377714 15 / 18

Accessories GEMÜ 1219 Cable socket / cable plug M12 The GEMÜ 1219 is a connector (cable socket / cable plug) M12, 5-pin. Straight and/or 90 angled plug type. Defined cable length or with threaded connection without cable. Various materials available for the fixing nut. Ordering information Connection X2 - network connection M12 cable plug, straight, 4-pin GEMÜ 1219 Ethernet/M12 cable Fitted with a 1 metre cable set Fitted with a 4 metre cable set Fitted with a 15 metre cable set Connection X3 analogue/digital inputs and outputs M12 cable socket, straight, 8-pin M12 cable socket, angled, 8-pin Without cable dia. 6-8 mm Fitted with a 2 metre cable set, PVC/grey Fitted with a 5 metre cable set, PVC/grey Without cable dia. 6-8 mm Fitted with a 5 metre cable set, PUR black cable Connection X4 actual value supply, actual value input M12 cable plug, straight, 5-pin M12 cable plug, angled, 5-pin Ethernet RJ45 88450499 88450500 88450502 88304829 88475143 88475147 88422823 88374574 Without cable PG7 Nickel-plated brass 88208641 Fitted with a 2 metre cable set, PUR black cable Fitted with a 2 metre cable set, PUR black cable Without cable dia. 6-8 mm Fitted with a 2 metre cable set, PUR black cable Fitted with a 2 metre cable set, PUR black cable 5 x 0.34, nickel-plated brass 5 x 0.34, nickel-plated brass 88208643 88208644 Nickel-plated brass 88208645 5 x 0.34, nickel-plated brass 5 x 0.34, nickel-plated brass 88208649 88208650 16 / 18

Specification sheet for designing regulating cones for globe valves Project (customer) Date Contact person Calculation number (GEMÜ) Telephone E-Mail Technical requirements Medium 1) Requirement characteristic 1st operating point maximum flow 2nd operating point medium flow 3rd operating point minimum flow Media temperature 4) Inlet pressure Outlet pressure 2, 3) Flow rate in [m³/h] for liquids Gases 6) in [kg/h] for steam Type Required valve DN Valve body / Actuator Regulating cone Max. operating pressure Ambient temperature 5) Max. media temperature Connection Body material Seat seal PTFE Other Control function NC (normally closed) DA (double acting) Control pressure min max Characteristic linear modifi ed equal-percentage Other Double acting (normally open) 1) Liquid or gas? For media other than water or air, it is necessary to give data for the density and viscosity (with unit of measurement) of the medium. Otherwise we will assume data for standard conditions. 2) For steam especially, the minimum or maximum flow rate should be assigned to the appropriate inlet or outlet pressure. The temperature of the medium should also be taken into account. 3) GEMÜ recommends a positioning ratio of 1 : 10 (e.g. minimum flow rate is 10 m³/h and the maximum flow rate is 100 m³/h). Please note that the valve only controls reliably from a flow of about 10% of the max. Kv value on account of the valve opening behaviour. Other positioning ratios are possible on request or in the selection of standard regulating cones, see overleaf. 4) The media temperature range must be specified for steam applications. T = 20 C is assumed unless specified otherwise. 5) This data is not absolutely necessary. A room temperature of 20 C is assumed unless specified otherwise. 6) Basis: standard conditions 0 C, 1013.25 mbar. If conditions differ, please specify them. Globe Valves I Specifi cation sheet 1

Subject to alteration 10.2017 88524484 GEMÜ Gebr. Müller Apparatebau GmbH & Co. KG Fritz-Müller-Straße 6-8 74653 Ingelfingen-Criesbach, Germany Tel. +49 (0)7940 123-0 info@gemue.de