Electric pump EP-1. Electric pump with 1.9 kg reservoir:

Similar documents
Hydraulic pump HP-1. Type 1. Type 2

Electric Pump EP-1. Electric pump EP-1 with steel reservoir and pump element PE-120 V with manometer:

Pump elements. Pump elements. Pump elements PE 60 / PE 120 / PE 170 (with pressure limiting valve)

Central lubrication pump PICO

Progressive distributor MX-F

Progressive Central Lubrication Systems

Progressive distributor SXE-2

EUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Am Eichamt 8 DE Wertheim. Pump aggregate. Drive: Use:

Table of contents. Table of contents. Overview of progressive distributor Distributor bridge without outlet...

Progressive distributor SX-1

Hydraulic Pump. General description. Hydraulic circuit diagram

Motor-driven pump unit GSJB

ELECTRIC GREASE AND OIL PUMPS ILC-MAX

EUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Am Eichamt 8 DE Wertheim. Pump unit GMZ-E

LUBRICATION PUMP UCF CENTRAL LUBRICATION

PICO-tronic Integrated Electronic Control Systems

Electric barrel pump EFP-1 and EFPM-2 General, Fields of application und types of systems

TriboTec LUBRICATION PUMP VEG

Injection oilers, micro pumps for minimal quantity metering

Manually or pneumatically actuated piston pumps

Single-Line Centralized Lubrication Systems

Manually or pneumatically actuated Piston pumps

Product description Electric Lubrication pump Dynamis Maxx APPLICATION PRODUCT CHARACTERISTICS ADVANTAGES

LUBRICATION SYSTEMS PRELIMINARY WE MEASURE OUR SUCCESS BY YOUR UP-TIME SINCE 1927

For high-viscosity oils and fluid grease of NLGI grades 000, 00 For use in SKF MonoFlex single-line centralized lubrication systems

Special lubrication systems

Injection oilers, micro pumps

Injection Oilers, Micro Pumps

Models CHASSIS LUBE ELECTRIC GREASE PUMP Series "C" - Q3. MAY FORM Section

EUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Am Eichamt 8 DE Wertheim. Piston pump PMW. Air-actuated multiplunger pump

PPU, PHU Piston Pumps for progressive grease and oil systems, pneumatically or hydraulically actuated

EUGEN WOERNER GmbH & Co. KG Postfach 1661 DE Wertheim Am Eichamt 8 DE Wertheim

Models CHASSIS LUBE ELECTRIC GREASE PUMP Series "C" - 13C MAY FORM Page. Section - Q3

HDI Range Electric Lubrication Pumps

OPTIONS AUTOMATIC LUBRICATION SYSTEM

Grease-lubricating pump FF... DSK US (05.05)

MultiPort II Lubricator

Electronic Pressure Switches

AUTHORIZED DISTRIBUTOR DPX PROGRESSIVE DIVIDERS

QUICKLUB. Owner Manual Technical Description. LINCOLN GmbH Postfach 1263 D Walldorf Tel +49 (6227) 33-0 Fax +49 (6227) Tx

LUBRICATION PUMP UCD

LUBRICATION PUMP VEG CENTRAL LUBRICATION

lubrication systems PEGPEO 5N-10N-25N-210N pumps for progressive systems

Flow limiter SP/SMB 8... DSK US (09.04)

DPL MONOBLOCK PROGRESSIVE DIVIDERS

Contact Dial Thermometer

Quicklub. Pump Model 203 with Power Supply for VAC and Printed Circuit Board M08-M23. Owner Manual Technical Description

Model CHASSIS LUBE ELECTRIC GREASE PUMP Series "C"

LUBRICATION PUMP ACF CENTRAL LUBRICATION

Block metering device VPB. Block feeder for use in oil or grease lubrication systems

System description for cylinder lubrication and valve seat lubrication on large 4-stroke diesel engines

Piston Distributors, Metering Units

Product series DSA, DSB, DSC, DSD

Electronic Pressure Switches

LUBRICATION PUMP PMP CENTRAL LUBRICATION

Panel-mounted Thermostats

Chain lubrication, accessories Nozzles, oiling-brushes, reservoirs and other accessories for the chain lubrication EN

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

PSG product series. Modular feeder. For oil and grease For use in SKF ProFlex progressive and SKF CircOil circulating centralized lubrication systems

Flow limiter SP/SMB3 Flow limiter SP/SMB6

Catalog. Accessories Separ-Filter. Catalog: Accessories Separ-Filter Page 1 of 13

FZ-A Lubricator. Electric, Oil & Grease. General. Application. Operation. Features. Adjustment of Discharge Rate R2 03/09

Pneumatic High Temperature Clamps and Grippers

Proximity switches and switch brackets

Maintenance Instructions & Parts List

TWO-LINE ELECTRIC CHANGE-OVER VALVE

PROGRESSIVE DISTRIBUTOR PRA,PRB

Pump Autolub-M. Product description APPLICATION PRODUCT CHARACTERISTICS FUNCTION

lubrication systems CME Electric pump for oil and soft grease volumetric

Block feeder SPVS Used in oil or grease lubrication systems

LUBRICATION PUMP PMP CENTRAL LUBRICATION

Automatic Lubrication Systems

Piston Pumps with Reservoir

HIGH PERFORMANCE LUBRICATION SYSTEM

Rotary-Linear Actuator HSE4 Hydraulic / 100 Bar

PROGRESSIVE BLOCK DISTRIBUTOR BVA-N

Transmitters: Relay Valve VR4151/4152

CLP - Cartridge Lube Pump

REV lubrication systems PEGPEO Electropumps for progressive systems

Electric grease pump series L-EGP 230VAC / 400VAC

PTEX extruder pumps Pneumatic extruder pump for drums of grease up to NLGI grade 2

Block feeder SPVS Used in oil or grease lubrication systems

SERVICE & MAINTENANCE MANUAL

Grease lubricating pump FB DSK US (06.02)

Precision Lubrication

Components Parts of Quicklub Pumps P 223 and 233

DUOFLEX lubrication pumps

Manual. Air-hydraulic Drilling Unit Series BE 33. Read this manual before installation and commissioning of the product. Keep for future reference.

Electronic Pressure Switches

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation

IPVP High-pressure Internal Gear Pumps for Variable Speed Drives

Wedge clamps

INDECO LUBEMAXX. Operating and Assembly Manual INDECO LUBEMAXX

MultiPort II Lubricator

Flow limiter SP/SMB US

Grease Lubrication Pump FK

EUGEN WOERNER GmbH & Co. KG Postfach 1661 D Wertheim Am Eichamt 8 D Wertheim

MOTION GUARD - AUTOMATIC LUBRICATOR

Operating Instructions

Grease Pump Units For progressive and multiline systems, manually, pneumatically or hydraulically actuated

Transcription:

The BEKA-MA central lubrication pump model EP-1 is electrically actuated and has up to a maximum of independently operating lubricant outlets. A separate pump element is required for each outlet. Three pump elements with different flow rates are available, as well as a flowadjustable pump element (see page 7). This enables the grease quantity to be adapted to the requirement of the individual progressive distributor circuits. These pumps enable the delivery of commercial lubricants up to NLGI-class 2 at a working pressure of maximum 280 bar (adjusting of pressure relief valve). Electric pump with 1.9 kg reservoir: The EP-1 series pumps differ in reservoir size and control type. EP-1 can be controlled externally e. g. via PLC or an additional control unit S-EP 6. The pump can also be delivered with a number of different integrated controllers Integrated controllers: EP-tronic EP-tronic T1 BEKA-troni1 EP-T2 Electric pump EP-1 with 4 kg reservoir and integrated electronic controller: Technical data: Motor: Operating voltage: 12 V DC / 24 V DC Revolutions: 15 rpm Current consumption: Idling at + 20 C: 0.8A/ 0.4A Full load at + 20 C: 2.2A/ 1.1A Fuse: 5A/ A Pump: Max. operating pressure: 50 bar Adjusting of pressure relief valve 280 bar Permissible operating temperature: -5 C to +70 C (depending on the grease type) Reservoir size: Transparent reservoir: 1.9 kg, 2.5 kg, 4 kg 8 kg or 16 kg Steel reservoir: 2 kg or 4 kg Stirrer direction: counterclockwise Mounting position: Reservoir in vertical position Delivery rates: depending on pump element (see page 7) Protection type: IP5K9K as per DIN 40050 FU2152011112EN Lubricant: Greases up to NLGI-cl. 2 (excluding solid lubricants) 2 Mineral oils from 40 mm /s (cst) Integrated controller 1

Operation A DC motor (10) continually operates the eccentric cam (5) and pressure ring (6). This eccentricity effects the suction and pressure strokes of the delivery piston (7), whereby the integrated non-return valve (8) prevents the delivery media from being sucked back out of the main line. The stirrer (2) pushes the lubricant out of the supply container (1) through a screen (4), which reduces any air bubbles, to the suction area in the pump housing (). A scraper on the stirrer (2) enables a visual check of the lubricant volume still present in the transparent supply container (1). The pressure relief valve (9) is pre-set to 280 bar. 1 2 4 7 5 8 9 10 Pump element is drawing in: Pump element is delivering: 6 2

Connecting cable and terminal plan In standard configuration, the electric pump EP-1 is supplied directly connected via a 10 m cable. View from below with the cable directly connected: Terminal diagram: brown Ground, terminal 1 blue Ignition, terminal 15 Optional equipment, lower shell with bayonet connector: View from below with bayonet connector: At request, the electric pump EP-1 can also be delivered with bayonet connector with 10 m cable connected to the lower motor half-shell. This facilitates the replacement of the connection cable, e. g. after a cable break. The special design with bayonet connector must be specified in the order (see order key on page 1). Terminal diagram: brown blue Ground, terminal 1 Ignition, terminal15 2-wire connecting cable, length 10 m, with bayonet connector: Order-no: FAZ02499-22

Installation dimensions Reservoir models and installation dimensions: The electric pump EP-1 is available with 5 transparent reservoir sizes and with 2 steel reservoir sizes. Transparent reservoir models: Option with screw-on lid 1.9 kg reservoir Ø15 Ø150,5 Option with screw-on lid 2.5 kg reservoir 4 kg reservoir Ø180 174 12 209,5 255 Ø9,5 Pipe connection dia. 6 12 Ø9,5 Pipe connection dia. 6 29 Connecting cable, length 10 m 29 Connecting cable, length 10 m 152 152 10 107 185 10 107 197 172,5 25 14 172,5 25 14 4

Installation dimensions Transparent reservoir: 16 kg reservoir Ø225 8 kg reservoir Ø225 Z 525,5 0,5 212 281,5 M8 1 12 Ø9,5 Pipe connection dia. 6 7,5 107 29 14 152,5 Connecting cable, length 10 m (112,5) Z 9 10 152 Ø9,5 49,5 5

Installation dimensions Steel reservoir models: Ø146 4 kg reservoir 2 kg reservoir 152 10 182,5 12 185 02,5 107 Ø9,5 Pipe connection dia. 6 172,5 14 25 29 Connecting cable, length 10 m View from below with bayonet connector: 14,5 29 172,5 14 25 6

Pump elements Pump elements PE-60, PE-120 and PE-170: Technical data: Delivery rate Order-no (cm / stroke or revolution) (with pressure relief valve) PE-60 0.06 2152 99067 0000 PE-120 0.12 2152 99061 0000 PE-170 0.17 2152 99069 0000 Order-no Pressure relief valve 2152 0062 Pump element PE-120: Pressure relief valve set at 280 bar permanently Pump element PE-120 V: Delivery rate: - All pump element are set to full stroke by the manufacturer - max. delivery rate 0.12 cm at full stroke - Reduction 0.01 cm per notch = 1/2 revolution M 20 x 1.5 SW 24 Pipe dia. 6 66 Adjusting the delivery rate: - Remove plug screw (2) withallen key (SW 5). - Turn adjusting screw () with a screwdriver. - Turn clockwise to reduce delivery rate. - Turn counterclockwise to increase delivery rate. - Maximum stroke of adjusting screw is 2.4 mm = 6 notches. - 1 turn of adjusting screw is 0.8 mm = 2 notches. - Tighten plug screw (2) incl. sealing ring. Pump element PE-120 V: Pressure relief valve set at 280 bar permanently SW 24 M 20 x 1.5 2 Techical data: Delivery rate: 0.04 to 0.12 cm / stroke Regulation of delivery rate: 6 detents each 1/2 revolution Reduction: 0.01 cm per notch Delivery media: Greases from NLGI-Cl. 00/000 to NLGI-Cl. 2 Piston return: forced Order-no (with pressure relief valve): 2152 9906 0000 Order-no for pressure relief valve of PE-120 V: 2152 006 Installation of pump elements in electric pump EP-1: - Only install / remove when pump is off - Install pump unit with piston partially extended (4) insert at angle in top of housing bore (see diagrama). - When the piston head rests on pressure ring - move pump element into vertical position (see diagram B). - Piston head must run in guide ring groove. - Tighten pump element. - For removal, reserve above sequence. - When removing the pump element, ensure that the piston (4) is not left behind in the pump housing. Delivery rate (cm³) 0,12 0,11 0,10 0,09 0,08 0,07 0,06 0,05 0,04 0,0 0,02 0,01 0 0 1 2 4 5 6 Notches 0 0,5 1 1,5 2,0 2,5,0 Revolutions Installation instructions: Diagram A: Diagram B: 4 2 Pipe dia. 6 7

Special accessories malfunction indicator on pressure relief valve The pump elements for the electric pump EP-1 can be equipped with a visual malfunction indicator. If a malfunction occurs in the central lubrication system and operating pressure rises to 280 bar, the red control pin becomes visible. The grease escaping through the pressure relief valve is returned to the reservoir. Once the malfunction is rectified, the red control pin must be pushed back in. For ordering, the malfunction indicator must be selected by means of a special variant number (see order key on page 1). Subsequent installation is not possible. In case of damage, the parts of the malfunction indicator can also be ordered as parts or spare parts. A straight connector (see on right side) is used to connect a torn return hose. Pump element with visual malfunction indicator: 0.1 m Polyamide tube Order no: 100120068 and Double end connector Order no: 04060759 to reservoir to reservoir red control pin all OK Malfunction Malfunction indicator on pressure relief valve Order no: 215299061000 consisting of: Control pin and Control pin mounting device 8

Special accessories pressure relief valve with microswitch The microswitch located on the pressure relief valve is used to the monitor the maximum operating pressure in the central lubrication system. If a malfunction occurs in the system, the microswitch is triggered. The microswitch signal can be processed by any signal encoder already present, e. g. an on-board processor, or by an external or integrated controller. Pump element with microswitch: Technical data: Operating voltage: 10 to 60 V DC Maximum current load: I = 1.7A Contact type: 1 changeover switch Temperature range: -25 C to +85 C Protection type: IP 67 Connection: Cable, length 0.5 m, heat-sealed Opening pressure: preadjusted to 280 bar Pressure relief valve with micro switch for PE-60 to PE-170. Article-no.: 2152990610028 Microswitch Order-no: 1000 91 10 Pressure relief valve with micro switch and elbow plug connection M12 for PE-60 to PE-170. Article-no.: 215299119 approx. 82 M14x1,5 approx. 82 M14x1,5 Terminal diagram to connecting the microswitch to a external control unit: Apparent ohmic resistance NO (normally open contact) NC (normally closed contact) black blue brown 9

Special accessories grease level controller The electric pump EP-1 can be equipped with an electronic grease level controller to control the minimum grease level. A capacitive proximity switch is built into the pump reservoir for this purpose. This emits a signal as long as there is sufficient grease in the reservoir (standard). If the grease level sinks below a certain level, the proximity switch switches off the signal. The proximity switch can be evaluated by an external control unit or PLC or an integrated control unit. When connecting the grease level control to an intelligent controller (e. g. on-board computer, PLC), it must be taken into account that the grease level signal is only evaluated after a delay of 10 sec., meaning that only if the signal of the capacity proximity switch is missing permanently for over 10 sec., that lubricant reservoir is empty and the pump should be switched off (NO contact - black wire connected). If the white wire is connected (NC contact), the pump may only be switched OFF once the proximity switch issues a permanent signal for more than 10 sec. To ensure wire break monitoring, the NO contact should be used preferentially! for 2.5 kg reservoirs for 4 kg reservoirs for 8 kg reservoir Capacitive proximity switch Capacitive proximity switch min. grease level min. grease level Technical data: Operating voltage: 10 to 60 V DC Connecting method: PNP-turnkey Maximum current load: 250 ma Protection type: Switch: IP 67 Protection type: Plug: IP 54 Ambient temperature range: -25 C to +70 C Connection: 4-pole M12x1, plugable Capacitive proximity switch min. grease level Connection diagram: + U brown b Break contact white Masse Make contact blue black The brown wire (+U b) and the blue one (ground) are used for the voltage supply of the sensor. If the black wire is used as output of the sensor, it works as NO contact and signals +Ub as long as there is still grease in the reservoir (OK signal, no line rupture). If the white wire is connected to +U b, a signal is received when the grease level sinks below a minimum (NC contact) in the reservoir (empty signal). 10

Cable for connection of the grease level control The connection cable for the grease level control must be ordered separately. Two different cable types are available: To connect the grease level control, connection cables no. 1 with straight socket M12x1 with cable lengths of 2 m, 5 m and 10 m can be used: Socket M12x1 for connection to the grease level control Cable length 2 m 5 m 10 m Order-no. 1000 91 2458 1000 91 127 1000 91 2457 Similarly, the connection cable no. with right-angle socket M12x1 and a cable length of 5 m can be used: Socket M12x1, angular, to connect the grease level control Order-no.: 1000 912997 11

Filling the pump a) Standard filling via lubrication nipple with manual or pneumatic grease gun: Filling lubrication nipple b) Filling via filling socket: Remove lubrication nipple replace with filling socket for grease Order-no:2159 0061 006 Filling socket for grease Order no: 2159 006 009 Coupling box Order no: 2159 0062 009 c) Filling via filling press: Filling press Order no: 2081 00 26 Filling joining, straight Order no: 2152 0150 12

Order key Construction type Motor voltage without plug with bayonet connector Voltage Code 12 V 01 24 V 02 12 V 0 24 V 04 2152.... 000 Pump elements without PE-60 PE-120 PE-120 V PE-170 Outlet No 1 2 0 0 0 1 1 1 2 2 2 4 4 4 Fig. 000 001 002 00 004 010 011 012 01 014 020 021 022 02 024 00 01 02 0 04 040 041 042 04 044 Code 00 A1 A A4 A5 B0 B1 B2 B B4 C0 C1 C2 C C4 D0 D1 D2 D D4 E0 E1 E2 E E4 Fig. 100 101 102 10 104 110 111 112 11 114 120 121 122 12 124 10 11 12 1 14 140 141 142 14 144 Code F0 F1 F2 F F4 N0 G1 G2 G G4 H0 H1 H2 H H4 H5 H6 H7 H8 H9 J0 J1 J2 J J4 Special variants 000 Fig. 200 201 202 20 204 210 211 212 21 214 220 221 222 22 224 20 21 22 2 24 240 241 242 24 244 Code 01 K1 K2 K K4 L0 L1 L2 L L4 02 M1 0 M M4 52 N1 N2 5 N4 P0 P1 P2 P P4 Fig. 00 01 02 0 04 10 11 12 1 14 20 21 22 2 24 0 1 2 4 40 41 42 4 44 Code 41 Q1 Q2 Q Q4 R0 R1 R2 R R4 S0 S1 S2 S S4 42 T1 T2 4 T4 U0 U1 U2 U U4 Fig. 400 401 402 40 404 410 411 412 41 414 420 421 422 42 424 40 41 42 4 44 440 441 442 44 444 Code V0 V1 V2 V V4 W0 W1 W2 W W4 0 1 2 4 Y0 Y1 Y2 Y Y4 Z0 Z1 Z2 Z Z4 Reservoir size (kg) without grease level control with LM min. plug connection M12x1 in reservoir cover Special variants: 028 = Pump elements with microswitch 257 = Pump elements with malfunction indicator and grease repatriation Ordering example pump elements: 1 PE-120 installed in outlet position 1: Fig. = 200 -> Code = 01 Transparent reservoir Steel reservoir 1,9 2,5 4 8 16 2 4 8 27 25 51 0 52 5 5 7 1 26 6 2 1 1