Temposonics. G-Series Analog or Start/Stop. Absolute, Non-Contact Position Sensors. Temposonics GP and GH Stroke length mm depends on output

Similar documents
Temposonics. G-Series Analog Redundant. Magnetostrictive Position Sensors. Redundancy for enhanced safety

Temposonics. R-Series DeviceNet. Magnetostrictive Position Sensors. Intelligent Design. Temposonics RP and RH Measuring length mm SENSORS

Temposonics. E-Series Analog + Start / Stop. Magnetostrictive Position Sensors. Temposonics EP Measuring range mm / mm SENSORS

Temposonics. M-Series Analog. Magnetostrictive Position Sensors. Temposonics MH Measuring length mm SENSORS

Temposonics. M-Series Analog. Absolute, Non-Contact Position Sensors. Temposonics MH Measuring length mm. Compact Sensor for Mobile Hydraulics

Temposonics. Absolute, Non-Contact Position Sensors. MH Series. Temposonics MB Analog. Technical Data / Description

Temposonics. M-Series Analog Redundant. Absolute, Non-Contact Positions Sensors. Temposonics MT Measuring length mm

Temposonics. M-Series PWM. Absolute, Non-Contact Position Sensors. Temposonics MH Measuring Length mm. Document Number Revision B

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

Temposonics ATEX. Magnetostrictive Linear Position Sensors. DATA SHEET High Pressure Housing (HPH) The Measurable Difference

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

Temposonics. M-Series Analogue / SIL2* Absolute, Non-Contact Position Sensors. Temposonics MH Measuring Length mm

Temposonics. R-Series Analog. Absolute, Non-Contact Position Sensors. Temposonics RP and RH Measuring length mm

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

Temposonics. Magnetostrictive, Absolute, Non-contact Linear-Position Sensors. R-Series Models RP and RH Ethernet POWERLINK.

Temposonics. R-Series Analog. Absolute, Non-Contact Position Sensors. Temposonics RP and RH Stroke length mm

Temposonics. MH-Series Analog Redundant. Absolute, Non-Contact Positions Sensors. Temposonics MT Measuring length mm

Temposonics. Magnetostrictive, Absolute, Non-contact Linear-Position Sensors. R-Series Models RP and RH DeviceNet Output.

R-Series Rod Model RS. Data Sheet. Model RS Rod-style sensor with IP68/IP69K Super Shield Housing. Interrogation Return wire.

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

Temposonics. Magnetostrictive Linear Position Sensors. DATA SHEET GBS Analog

ANALOG. PARAMETER SPECIFICATION Measured Variable: Displacement, Velocity (magnitude only) 16 bit or mm, whichever is greater

Temposonics. Magnetostrictive Linear-Position Sensors. R-Series Model RP and RH Sensors Synchronous Serial Interface (SSI) Output D

Temposonics. Magnetostrictive Linear Position Sensors. MHRM Analog Data Sheet. For embedded or externally threaded installation

Temposonics. Magnetostrictive Linear Position Sensors. MH-Series MH5 Analog Data Sheet

Temposonics. Absolute, Non-Contact Position Sensors. MH Series. Temposonics MH Analog /Digital. Technical Data / Description

Temposonics. Magnetostrictive Linear Position Sensors. TH Analog Data Sheet

SSI. Synchronous Serial Interface

Temposonics. Magnetostrictive Linear Position Sensors. TH CANbus Data Sheet

Temposonics. Absolute, Non-Contact Position Sensors. OPERATION MANUAL R-Serie Analog. The Measurable Difference

Temposonics. Absolute, Non-Contact Position Sensors. MH Series. Temposonics MH 200. Technical Data / Description. Compact sensor for mobile hydraulics

Temposonics. Magnetostrictive Linear Position Sensors. TH Analog SIL 2 capable Data Sheet

Temposonics Magnetostrictive Linear Position Sensors. Temposonics GB-Series Brief Instructions

Temposonics Absolute, Non-Contact Position Sensors

CANBUS G. Up to mm ( in.) < ± 0.01% of full stroke or ± 0.04 mm ( in.), whichever is greater*

Temposonics. R-Serie Catalog. 0.5 μm. Absolute, Non-Contact Position Sensors. The Measurable Difference

Temposonics Absolute, Non-Contact Position Sensors

Temposonics. Magnetostrictive Linear Position Sensors. GB-Series Analog Operation Manual

Temposonics Magnetostrictive Linear Position Sensors. Temposonics E-Series Brief Instructions

Level Plus. Magnetostrictive Liquid Level Transmitters with Temposonics Technology. LP-Series SE Replacement Installation Manual

Profibus-DP Output. Profibus-DP output: Standard Profibus-DP signal. Profibus Output

L E V E L P L U S M - S E R I E S ANALOG

Temposonics. Magnetostrictive Linear Position Sensors. MH-Series Flexible MH Installation Manual

Part No Rev. E

TECHNICAL PAPER. Magnetostrictive Position Transducers in Medical Applications. David S. Nyce. Introduction

Temposonics. Temposonics R-Series. Instruction Manual. EtherCAT Interface. Absolute, Non-Contact Position Sensors. Rod model Temposonics-RH

Temposonics. Magnetostrictive Linear Position Sensors. R-Series Ethernet/IP TM Operation Manual

Temposonics Magnetostrictive Linear-Position Sensors

958A Compact Housing Linear Displacement Transducer

ACTUATORS POSITION SENSOR

JUMO MIDAS S07 MA. OEM Pressure Transmitter - Maritime Approved. Applications. Brief description. Special features.

Magnetostriction in Automotive Position Measurement

958A Compact. Series 958 Compact Housing LDT. Housing ABSOLUTE PROCESS CONTROL KNOW WHERE YOU ARE... REGARDLESS

JUMO MIDAS S05 Pressure transmitter Type

Data Sheet for Linear Sensors

PRODUCT SELECTOR GUIDE

PRODUCT SELECTOR GUIDE

Powerful, durable and quick to mount. Magnetic and cylinder sensors from ifm electronic.

JUMO DELOS SI. Precision pressure transmitter with switching contacts and display. Application. Brief description. Key features.

JUMO MIDAS S06. OEM-Pressure Transmitter Low Pressure. Applications. Brief description. Customer benefits. Special features

JUMO MIDAS C18 SW. OEM pressure transmitter - seawater. Applications

Your Global Automation Partner. LTX Linear Position Sensors with SSI Interface. Operating instructions

Temposonics. Magnetostrictive Linear Position Sensors. R-Series Profinet IO RT Operation Manual

JUMO MIDAS S05. OEM Pressure Transmitter Universal. Applications. Brief description. Customer benefits. Special features

Temposonics GENERATION THE NEW I AM. Magnetostrictive Linear Position Sensors. Temposonics R-Series V Profinet RT & IRT Operation Manual

Solid State Electronic Pressure Switch with Integral LED Display Model PSD-10

Type A-10 General Purpose Pressure Transmitter

Linear Position Sensing and Measurement. The appropriate measuring principle for the optimal solution

Temposonics. Magnetostrictive Linear Position Sensors. E-Series IO-Link Operation Manual

Differential Pressure Sensors

Linear-Transducer LMP48 - A

Electric Mini Slides MSC-EL

Standard cylinders DDPC, with measured-value transducer DADE

Pressure Transmitter. Pressure transmitter with compact design Model EDC-K. Electronic. Applications. Special Features.

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

DCT 533. Industrial Pressure Transmitter with IO-Link Interface. Stainless Steel Sensor

Electronic Sensors Solid State, Reed and Proximity Sensors Feedback Packages

PRM7-04. Functional Description HA /2012. Proportional Directional Control Valves. Replaces HA /2009

3RG4 BERO Inductive Proximity Switches

Rotary Sensor potentiometric Heavy-duty. Series IPX-7900

PRM7-06. Functional Description HA /2006. Proportional Directional Control Valves. Replaces HA /2002

PRM7-06. Functional Description HA /2014. Proportional Directional Control Valves. Replaces HA /2013

Low Profile DC Power Supply with Zero Voltage Soft Switching

Pneumatic cylinders, piston-ø 8 25 mm Single acting DIN ISO 6432

Power Plugs for Proportional Valves (12 volt supply)

Differential Pressure Sensors

DA-053 Series. Overview. Applications. Features & Benefits. Datasheet. 53lb-in (6 Nm), Non-Spring Return Damper Actuators

Paddle-wheel flow controller with optical principle for On/Off control

fluid technology temperature sensors 1600 intelligent temperature sensor membrane keyboard, USB opto interface

CD34CNFLFxxx. Capacitive sensor, Foreground Suppression. Main features. Main functions. Description

Sentronic LP IO-Link CLASS A 617 Series. Proportional Technology

PROPORTIONAL VALVES. G1/4, G3/8 and G1/2 tapped body or subbase mounted body with digital pressure control

CTE7000 / CTU7000 Series Miniature pressure transmitters

PROPORTIONAL VALVES Sentronic D - G 1/8 to G 3/8 tapped body or G 1/8 - G 1/4 subbase mounted body with digital pressure control

CTE9000 / CTU9000 Series OEM pressure transmitters for industrial media

HUMIDITY / TEMPERATURE TRANSMITTER

8710 EN. Potentiometric Displacement Sensors. Models 8710, 8711

0 to 100 up to 0 to PSI (gage) Packard Electric Metri-Pack 150 Series, M12-4 Pole* 1/4-18 NPT ma, VDC, 0-5 VDC, 0-10 VDC

SAX Electronic Valve Actuator

STT280 SEALED TILT SENSOR

Transcription:

Temposonics Absolute, Non-Contact Position Sensors G-Series Temposonics GP and GH Stroke length 50...7600 mm depends on output C GP GH Position ~ Time Output signal indicating to magnet's position Sensor element Signal converter The Temposonics linear position transducers are based on magnetostriction technology. Magnetostriction is a ferromagnetic material phenomenon which relates a dimensional change of the material to its magnetization properties. It is the product of a general coupling between the magnetic and elastic transport properties of the materials crystal lattice. This affect is typically on the scale of a few parts per million. It is quasi linear with the material s magnetization, may be positive or negative, and reaches a maximum at magnetic saturation. It is reversible, but exhibits a hysteretic affect if the magnetization does so. Magnetostriction was characterized in the late 19th century, the longitudinal version is called the Joule effect, the torsional version is called the Wiedemann effect, and the reciprocal effect where mechanical stress changes the magnetic properties is referred to as the Villari effect. The extremely robust sensor, ideal for continuous operation under harshest industrial conditions is completely modular in mechanic and electronic design. - A profile or rod-shaped sensor housing protects the sensing element in which gives rise to the measurement signal. - The sensor head accommodates the complete modular electronic interface with active signal conditioning. Double encapsulation ensures high operating safety and optimum EMC protection. - The position transmitter, a permanent magnet - fixed at the mobile machine part - drives contactlessly over the sensor s stroke and starts measuring through the housing wall.

Measuring variables position, liquid level Stroke length - Analog profile/rod models: 50...2500 mm (longer stroke lengths are available on a custom basis) - Start/Stop profile model: 50...5000 mm, rod model: 50...7600 mm Voltage Current Start/Stop pulse 0...10 / 10...0 / -10...+10 / +10...-10 VDC (min. load controller: > 5 kohms) 4(0)...20 ma / 20...4(0) ma (min/max. load: 0/500 Ohms) RS422 serial differential signal Position measurement: - Null/Span adjustment 100 % of electrical stroke (min. range 50 mm) - Resolution analog: infinite digital (start/stop): 0.1 mm; 0.01; 0.005 mm (controller dependent) - Linearity 1 < ± 0.02 % F.S. (minimum ± 50 μm) - Repeatability < ± 0.001 % F.S. (minimum ± 2.5 μm) - Hysteresis < 4 μm - Update time analog: < 1 ms typical digital (start/stop): controller and stroke dependent - Ripple < 0.01 % F.S. Magnet speed Operating temperature Dew point, humidity Ingress protection 2 Shock test Vibration test EMC test Diagnostic display LEDs beside connector Profile model: aluminum Sensor stroke aluminum magnet slider or removable U-magnet Rod model: aluminum Rod with flange stainless steel 1.4301 / AISI 304 -Pressure rating 350 bar, 700 bar peak Ring magnets, U-magnets any -40 C...+80 C 90% rel. humidity, no condensation profile: IP 65, rod: IP 67, IP 68 for cable outlet 100 g single hit, IEC-Standard 60068-2-27 15 g / 10...2000 Hz, IEC-Standard 60068-2-6 (resonance frequencies excluded) Electromagnetic emission EN 61000-6-4 (for use in industrial environment) Electromagnetic immunity EN 61000-6-2 The sensor meets the requirements of the EC directives and is marked with CE Mounting position Profile Rod Connection type Supply voltage - Polarity protection - Overvoltage protection Current drain Ripple Electric strength any orientation movable mounting clamps or T-slot nuts in base channel threaded flange M18 x 1,5 or 3/4" -16 UNF-3A, hex nut M18 mounting plate and screws from antimagnetic material 6 pin connector 24 VDC (-15 / +20 %); UL Recognition requires an approved power supply with energy limitation (UL 61010-1), or Class 2 rating according to the National Electrical Code (USA) / Canadian Electrical Code. up to -30 VDC up to 36 VDC 100 ma typical < 0.28 Vpp 500 VDC (DC ground to machine ground) mm + 0,3 + 0,2 + 0,1 0,0-0,1-0,2-0,3 0 100 200 300 400 500 600 700 800 900 1000mm Sensor Temposonics 1 with position magnet # 251 416-2. 2 The IP rating is not part of the UL recognition I 2 I

Temposonics Temposonics GP offers modular construction, flexible mounting configurations and easy installation. Position measurement is contactless via two versions of permanent magnets. - A sliding magnet running in profile housing rails. Connection with the mobile machine part is via a ball jointed arm to taking up axial forces. - A floating magnet, mounted directly on the moving machine part, travels over the profile at a low distance. Its air-gap allows the correction of small misalignments at installation. Null Position Magnet slider 49 12 45 9,5 Ø 5,5 e. g. for M5x20 35,6 50 68 Connector outlet D60 2 EMC M16 12 75 28 28 Mounting clamp, movable Null Position U-Magnet antimagnetic support M4 Active stroke Stroke length 50...5000 depends on output 14,5 inactive 66 28 Cable outlet R02 Cable outlet H02 30 (not included in delivery, please order separately) Magnet slider S Magnet slider V Part no. 252 182 Part no. 252 184 43 14 20 57 M5 14 M5 U-Magnet OD33 Part no. 251 416-2 60º Ø 4,3 on bolt circle Ø 24 24 40 Rotation: Vertical 18º Horizontal 360º 24 Rotation 18º 13.5 Ø 33 Height: 8 mm GFK, Magnet Hardferrite Ball joint CuZn39Pb3 nickel plated Weight ca. 30 g -40... +75ºC GFK, Magnet Hardferrite Ball joint CuZn39Pb3 nickel plated Weight ca. 30 g -40... +75ºC Composite PA-Ferrite-GF20 Weight ca. 11g -40... +100ºC Surface pressure max. 90 N/mm 2 Fastening Torque for M4 screws max. 1 Nm All dimensions in mm I 3 I

Temposonics Temposonics GH with a pressure-resistant stainless steel flange and sensing rod is suitable for use in hydraulic cylinders and externally in all applications where space is a problem. Position measurement is done via ring or U-magnets travelling along the sensing rod without any mechanical contact. the completely operable sensor cartridge can be replaced for servicing easily without opening the fluid circuit. 49 25 Null Position Ring magnet Rod Ø 10 44 Connector outlet D60 12 10 80 Active stroke inactive 51 Stroke length 50...7600 63,5 / 66 * depends on output * > 5000 * >5000 mm mm stroke length EMC M16 Cable outlet R02 Cable outlet H02 (see profile style) 30 Option: : Oil-resistant sensor with fluorelastomer housing-seal Threaded flange M18x1,5 or 3/4"-16 UNF-3A Hex. 46 Ring magnet (not included in delivery, please order separately) Ø 4,3 on bolt circle Ø 24 Height: 8 mm 60º Ø 4,3 on bolt circle Ø 24 Height: 8 mm Ring magnet OD33 Part no. 201 542-2 U-magnet OD33 Part no. 251 416-2 Ø 33 Ø 13,5 Composite PA-Ferrite-GF20 Weight ca. 14 g -40... +100ºC Surface pressure max. 40 N/mm 2 Fastening Torque for M4 screws max. 1 Nm Ø 33 Ø 13,5 Composite PA-Ferrite-GF20 Weight ca. 11 g -40... +100ºC Surface pressure max. 40 N/mm 2 Fastening Torquefor M4 screws max. 1 Nm Ø 25,4 Height: 8 mm Ring magnet OD25,4 Part no. 400 533 Composite: PA-Ferrite Ø 13,5 Weight ca. 10 g -40... +100ºC Surface pressure max. 40 N/mm 2 All dimensions in mm I 4 I

Temposonics MTS Sensors is proud to introduce our new G-Series linear position sensors utilizing our next generation technology platform. G-Series sensors feature a microprocessor-based design with enhanced diagnostics and programmability to maximize backwards compatibility. Temposonics G-Series with analog outputs provide direct analog outputs including voltage and current, forward or reverse acting. All outputs allow full adjustment of Null and Span setpoints (minimum range 50 mm between setpoints) inside the active electrical stroke length. Since the outputs are direct, no signal conditioning electronics are needed when interfacing with controllers or meters. Integrated LEDs (green/red) provide basic visual feedback for normal sensor operation and troubleshooting. LED ON OFF Normal function ON Flashing Missing external start signal ON ON Magnet not detected Flashing OFF Serial programming mode Position Pin Pin 1 GY V/mA Stop (-) Pin 2 PK DC ground Stop (+) Pin 3 YE USB-programmer Start (+) Pin 4 GN USB-programmer Start (-) Pin 5 BN +24 VDC (-15/+20 %) The digital Temposonics G-Series is equipped with a start/stop output. The sensor requires a start signal from an external indicator in the control system and returns a stop signal corresponding to the magnet s position. The time elapsed between the two signals is proportional to the position. Time measurement is done by the control unit and used for calculating the position value. Option multi-magnet measurement: One Sensor can detect the positions of several magnets simultaneously. Displacement ~ Time Pin 6 WH DC ground (not included in delivery, please order separately) 54 54 Ø 18 38 Ø 19.5 Housing: zinc, nickel-plated Termination: solder Contact insert: silver plated Max. cable-ø: 6...8 mm Housing: zinc, nickel-plated Termination: solder Contact insert: silver plated Max. cable Ø: 6...8 mm All dimensions in mm I 5 I

Normally, the sensor is firmly installed - fixed on a straight surface of the machine with movable mounting clamps or M5 screws in base channel - whilst the magnet is mounted at the mobile machine part. Mounting clamp with screws M5x20 Tightening torque: max. 5 Nm T-slot Nut in base channel max. 5 mm When used for direct stroke measurement in fluid cylinders, the sensor s high pressure, stainless steel rod should be installed into a bore in the piston head/rod assembly as illustrated. That guarantees a longlife and trouble-free operation - independent from the used hydraulic fluid. The sensor cartridge can be removed from the flange and rod housing while still installed in the cylinder. This procedure allows quick and easy sensor cartridge replacement, without the loss of hydraulic pressure. Flange with tube becomes a permanent part of the cylinder 1 2 Do not exceed max. gap of 3 mm (± 1) M5 1 U-Magnet 2 Mounting plate and screws non-ferrous material Mount the sensor via flange thread or a hex nut. If possible, non-magnetizable material should be used for mounting support (dimensions as shown). With horizontal mounting, longer sensors (from 1 meter) must be provided with mechanical support. Recommended is sealing of the flange facing with O-Ring (e.g. 22,4 x 2,65) in a cylinder cover nut or an O-Ring 15,3 x 2,2 in undercut. Electronic head + sensor element, easy to replace in field with two screws M4 (2.5 mm hexagon socket) Fastening torque 1.3 Nm With installation of the position magnet into a float, the application range of G- series extends substantially. These highly precise float sensors supply exact level values or - provided with suitable floats - interface heights e.g. in the processindustry or laboratory technology etc. - Density 720 kg/m3 - Material 1.4571 polished AISI 316 Ti - Pressure < 25 bar On delivery: O-Ring 15,3 x 2,2 See ISO 6149-1 All dimensions in mm I 6 I

Temposonics G GP - Profile GH - Hydraulic rod 2 or 3 digits Profile Temposonics GP: S - Magnet slider, joint at top V - Magnet slider, joint at front - U-magnet, OD33 Rod Temposonics GH: - Flange M18 x 1,5 (Standard) V - Flange M18 x 1,5 (Fluorelastomer housing-seal) S - Flange 3/4" - 16 UNF - 3A - Profile/Rod 0050...2500 mm - Profile: 0050...5000 mm / Rod: 0050...7600 mm Standard: up to 1000 in 50 mm, greater 1000 in 250 mm steps Other lengths upon request - 6 pin male receptacle M16-2 m PVC cable w/o connector, option: R01...R10 (1...10 m) - 2 m PUR cable w/o connector, option: H01...H10 (1...10 m) - +24 VDC = 0...10 VDC = 10...0 VDC = -10...+10 VDC = +10...-10 VDC = 4...20 ma = 20...4 ma = 0...20 ma = 20...0 ma = Start/Stop - Option: R0X = If more than 1 magnet, denotes number (2...9 pcs.) for start/stop multi-magnet measurement Sensor,, 2 mounting clamps up to 1250 mm + 1 clamp for every additional 500 mm Sensor, O-ring, please order magnets separately. Magnet slider type»s«252 182 Magnet slider type»v«252 184 U-Magnet OD33 251 416-2 Ring magnet OD33 201 542-2 Ring magnet OD25.4 400 533 Magnet float 251 447 Collar 560 777 Hex nut 500 018 Mounting clamp 400 802 T-slot nut M5 for base channel mounting 401 602 6 pin female cable connector M16 370 423 6 pin 90 -female cable connector M16 370 460 PVC-cable 3 x 2 x 0.14 mm 2 530 032 PUR-cable 3 x 2 x 0.25 mm 2 530 052 MTS-Servicetools Analog Hand-Programmer G 253 853 Analog USB-Programmer G, incl. power supply 253 145-1 100...240 VAC / 24 VDC, connection cable and CD-ROM Digital USB-Programmer G, incl. power supply 253 146-1 100...240 VAC / 24 VDC, connection cable and CD-ROM 500 mm 25 mm 500...2500 mm 50 mm 2500...5000 mm 100 mm > 5000 mm 250 mm < 500 mm 5 mm 500...750 mm 10 mm 750...1000 mm 25 mm 1000...2500 mm 50 mm 2500...5000 mm 100 mm > 5000 mm 250 mm I 7 I

Document Part Number: 551383 Revision C (EN) 06/2014 MTS and Temposonics are registered trademarks of MTS Systems Corporation. All other trademarks are the property of their respective owners. Printed in Germany. Copyright 2014 MTS Sensor Technologie GmbH & Co. KG. Alterations reserved. All rights reserved in all media. No license of any intellectual property rights is granted. The information is subject to change without notice and replaces all data sheets previously supplied. The availability of components on the market is subject to considerable fluctuation and to accelerated technical progress. Therefore we reserve the right to alter certain components of our products depending on their availability. In the event that product approbations or other circumstances related to your application do not allow a change in components, a continuous supply with unaltered components must be agreed by specific contract. MTS Sensor Technologie GmbH & Co. KG Auf dem Schüffel 9 58513 Lüdenscheid, Germany Tel. + 49-23 51-95 87 0 Fax + 49-23 51-5 64 91 E-Mail: info.de@mtssensors.com www.mtssensors.com MTS Systems Corporation Sensors Division 3001 Sheldon Drive Cary, N.C. 27513, USA Tel. + 1-919-677-0100 Fax + 1-919-677-0200 E-Mail: info.us@mtssensors.com www.mtssensors.com MTS Sensors Technology Corp. 737 Aihara-cho, Machida-shi, Japan Tel. + 81-42-775-3838 Fax + 81-42-775-5516 E-Mail: info.jp@mtssensors.com www.mtssensors.com