Variable Area Flowmeters Ori-Flowrator TM Meters

Similar documents
Variable Area Flowmeters VA Master TM Indicating Flowrator Meters 10A4500

Model Connections Max. Flow Range (H 2 O) 10A A3220 Horizontal ¼ NPT 100 l/h. 10A3225/55 Vertical ¼ NPT 100 l/h. Vertical 1 NPT Vertical 1 G

INSTRUCTION MANUAL. VARIABLE AREA FLOWMETERS 10A2235 Rev.5 RATOSIGHT FLOW RATE INDICATORS

Variable Area Flowmeters Armored Purgemeter

ABB Automation. Variable Area Dial Flow Indicator Series 10A2227. Series 10A2227 Variable Area Dial Flow Indicator

Field IT Electro-Magnetic Flowmeters Sensors

Electro-Magnetic Flowmeters Sensors MagMaster MFE

INSTRUCTION MANUAL. with Parts List FLOW PRODUCTS 10A4500/10A4600 DESIGN LEVEL B V/A MASTER FLOWMETERS PN ABB Instrumentation

RCM - Direct Reading Flowmeters

Differential Pressure - Primary Flow Element Wedgemeter II Series WM: C/F/P

Glass Tube Full-View Flowmeters

Brooks GT1000 Series. Industrial Glass Tube Variable Area Flowmeters. GT1000 Series. Data Sheet DS-VA-GT1000-eng January, 2008

BYPASS ROTAMETERS FOR MEASURING RATE OF FLOW IN LARGE PIPELINES

Liquid filters _ 302. Deaerators. Product Bulletin

RCM. Direct Reading Flowmeter. for Liquids or Gases

Glass Tube Flowmeter Model GT1000

MEMFlo MFTV METAL BODIED FLOW METER WITH CLEAR TOP

VAREA-METER FLOW MEASUREMENT BY-PASS TYPES

KDM ARMORED FLOW METER & SWITCH

ORIFICE PLATE flow meters

Analytical Instruments Two-Electrode Conductivity Sensors

GA 24 Heavy-duty variable area flowmeter

Metal tube flowmeters Series M21 Variable area flowmeter for low flows of liquids, gases and steam

WP Series Hydraulic & Pneumatic Flow Monitors Illustrated Price List

BASIC IN-LINE LIQUID FLOW RATE MONITORS. Data Sheet No. B-699. Select from aluminum, brass or stainless steel to meet system and liquid requirements.

Model 788DVC DIGITAL CONTROL VALVES

User Guide IM/TORBAR-EN Rev. D. Averaging pitot tubes

ABB Instrumentation. MagMaster MFE Series Electromagnetic Sensors. Specifications. MagMaster - bringing unsurpassed flowmetering performance

KDG/KDF - Flow Meter and Flow Switch

VALFONTA PRESSURE REGULATOR WITHOUT AUXILIARY ENERGY EXCESS PRESSURE VALVE (PRESSURE RELIEF VALVE) MODEL S1 MAIN CHARACTERISTICS

Introduction Parker are designed for uni-directional flow control of fluids and gases in industries such as chemical processing, oil and gas productio

Actuators & Positioners Pneumatic Actuators Series UP1/2/3/4/5/6

Series 105 Simplex Strainer Cast Iron Swing Bolt O-Ring Closure, Flanged Connection Class 125 ANSI Flat Face Flange Rating VENT 'A' FLOW

Field Variable Area Flowmeters BFP Global Purgemaster

RUN ACCUM. TOTAL STOP BAT LOW HIGH

KB Series self averaging pitot flowmeter for gas, liquids and steam flows

Bray/McCannalok High Performance Butterfly Valves Technical Manual

Variable area flowmeter H 250

SECTION Pressure & Temperature Control

UniMag DT Series Electromagnetic Flow Tubes

P200 Pressure Regulator

Satellite photo of cloud vortices caused by a mountain (Courtesy of our friends at NASA) tekvorx Operation Showing Simplified Construction

Adjustable Port Valves for HOT or COLD AIR, GAS, OIL, WATER, STEAM

VLM20 In-line Vortex Flowmeter

Vortex Flowmeter Model DVE

METAL VAREA-METER STRAIGHT THROUGH TYPE ROTAMETER

TRANSMITTER ATTACHES TO THIS SURFACE

Fisher 2506 and 2516 Receiver Controllers

SECTION METERS AND GAGES FOR HVAC PIPING

F-2700 SERIES INSERTION VORTEX FLOW METER

P95H Regulator Applications P95H Part Matrix Specifi cations Materials of Construction P95H Flow Coeffi cients Wide Open Coeffi cients

F-2700 SERIES INSERTION VORTEX FLOW METER

Model 5400 / 5450 Control Valve

The readings you need, right where you need them. AX Series Vortex Meters

ANGLE SEAT AIR ACTUATED VALVES 2 Way (2/2)

Electromagnetic flowmeters for water and seewage

P200 Pressure Regulator

Vortex Eggs Delta Flowmeter

P200 Pressure Regulator

ORIFLO CONTENTS COST EFECTIVE FLOW MEASUREMENT FOR LIQUIDS AND GASES INTEGRATED ORIFICE FLOWMETERS GENERAL FEATURES MAIN APPLICATIONS

Accutubes. Accuracy True double averaging design +1% of rate accuracy +0.1% repeatability Tested and certified by independent flow labs

Check Valves (C Series) Catalog 4130-C Revised, July 2004

FloCheck is a precision engineered, twin plate check valve suitable for product or service lines, wherever non-return protection is required.

ISTEC MAGNETIC METERS

O-100 Series GLASS TUBE TYPE ORIFLOMETER BEST COST EFFECTIVE FLOW MEASUREMENT EVEN FOR LARGE SIZE LINES GENERAL STANDARD SPECIFICATION MODEL CODE

DPT TARGET TYPE FLOWMETERS

TUBE FLOW METERS. design features INTERCHANGEABLE. 150 mm Meter with CV TM Valve

Applications Closed Head Foam-Water Sprinkler Systems Aircraft Hangars Flammable Liquid Warehouses, Drum Storage Facilities

FUNDAMENTALS OF ORIFICE METERING Ken Embry FMC Measurement Solutions

O-1000 Series ORIFLOMETER MOST COST EFFECTIVE FLOW MEASUREMENT GENERAL STANDARD SPECIFICATIONS TYPES AND FUNCITON

Rosemount 1195 Integral Orifice Primary Element

Multivariable Vortex Flow Meter

O-180/780 Series ORIFLO METER COST EFECTIVE FLOW MEASUREMENT FOR LIQUIDS AND GASES GENERAL FEATURES MAIN APPLICATIONS

F-2600 SERIES INLINE VORTEX FLOW METER

Dual Chamber Orifice Fitting

King Instrument Company opened its doors in 1983 with one major goal:

VORTEX FLOW METTER DVH. Despriction. Advantages of the DVH Vortex Flow Meter

Armstrong In-Line and Insertion Vortex Flow Meters

Baumann Series Sanitary Regulators

WAFER STYLE ILBP PROPORTIONING MODULES WITH CHECK VALVE. NPR160 Approvals: UL, ULC

MODEL 106F TEFLON LIQUID FLOW SENSOR

Positive displacement flowmeter for continuous flow measurement

Pro-V Multivariable Flowmeter Model M24 In-line Vortex

PORTER FLOWMETERS & FLOW CONTROLLERS. Technology you can trust

Innova-Mass Model 240 & 241. Multivariable Mass Vortex Flow Meter. For information online...

The PL Series Pressure Air Release Valves. Sizes 1 thru 6 Available Compound Lever System Adjustable Buna-N Rubber Plunger. Crispin.

Mark 695 Series. Pressure Regulators Mark 695 Piloted Tank Blanketing Regulators. Piloted Tank Blanketing Regulator 3/4"- 1" Optional Features

Actuators & Positioners Electro-Pneumatic Converters I/P Signal Converters - TEIP 11 Model without Booster Stage

GRINNELL Model B303 Grooved End Butterfly Valves with Gear Operators or Lever-Lock Operators General Description

OMP POSITIVE DISPLACEMENT FLOWMETERS

Introduction Parker are designed for uni-directional flow control of fluids and gases in industries such as chemical processing, oil and gas productio

ELECTRONIC CONTROLLER

Multivariable Vortex Flow Meter

Insertion magnetic inductive flowmeter

SATRON VDt Differential Pressure Transmitter

Flowrite 599 Series Two-Way Valves, 1/2 to 2- inch Bronze Body, ANSI 250

INSTRUCTION MANUAL. INTEGRAL ORIFICE FLOW ELEMENT with Upstream & Downstream Piping and Threaded Connections. 1330L Series, Model A IB-04H104_8

GRINNELL Model B302 and Model BN302 Grooved End Butterfly Valves with Gear Operators or Lever-Lock Operators General Description

RIM20 Rotor Insertion Flowmeter

Installation, Operation and Maintenance Manual. TOM WHEATLEY Piston Check Valve TOM WHEATLEY

Transcription:

Data Sheet (US) Variable Area Flowmeters Ori-Flowrator TM Meters 10B4000 Low installation cost Linear indication over 12-1/2 to 1 flow range Inexpensive method of measuring large flow rates in direct flow units Polycarbonate shield protects personnel from glass fragments in the event of accidental tube rupture. Rotatable end fittings Universal threaded process connections Metering tube can be removed for range change or cleaning with meter in line All stainless steel construction Ori-Flowrator TM Meters Series 10B4000

ORI-FLOWRATOR METERS The ABB Series 10B4500 Ori-Flowrator Meter is a variable area flowmeter used to measure large flows of liquids or gases in conjunction with a primary orifice plate. This meter is mounted in a by-pass line around the primary orifice. A ranging orifice, integral with the meter, proportions the by-pass flow to the main line flow. A 1/2-inch size meter is used to measure flow regardless of the main line pipe size. Since the float position in a variable-area flowmeter is linear with flow rate, the Ori-Flowrator meter can be used to indicate main line flow rate in direct flow units on a linear scale. Standard scales are graduated 8-100 percent full scale. A factor tag is permanently attached to each meter to convert scale reading to flow rate for primary elements with the same differential. Special scales graduated in direct flow units are available. The Ori-Flowrator meter is available with nonadjustable differential ranges of 0-25, 0-50, 0-100, 0-150, 0-200, 0-300 and 0-400 inches of water. (6.25 0-12.5, 0-25, 0-37.5, 0-50, 0-75, 0-100 kpa). Engineering Specifications Differential Ranges: 0-25, 0-50, 0-100, 0-150, 0-200, 0-300 and 0-400 inches water column (0-6.25, 0-12.5, 0-25, 0-37.5, 0-50, 0-75, 0-100 kpa) Performance Repeatability: 0.5% of full scale. Accuracy: ±4 per cent full scale reading when main line orifice plate is sized and installed as recommended. Materials of Construction Tube: Beadguided Borosilicate Glass Float and Range Orifice: 316 Stainless Steel 0 rings: Standard Buna N, Viton, EPR Packing (10B4600 only): Standard - neoprene; Optional - molded Teflon liner. Fittings: Stainless steel. Float Stops: Teflon Tube Rest Gaskets: Standard Klinger-Sil; Optional Teflon (10B4600 only) Glands (10B4600 only): Stainless steel Compression Screws (10B4600 only): stainless steel Meter Body: Type 304L stainless steel Tube Retainer Spring: Armco 17-7 ph stainless steel, external to fluid stream in 0 ring meters. Shield: Polycarbonate Scales Length: 10 inches (254 mm) Type: Standard Percentage on tube. Optional direct reading on external scale with blank tube. Mounting: Pipe line mounted is standard Connections: 1/2-inch NPT internal threaded Weight: 4 pounds (1,8 kg) Service Limits: Glass tube meters are not recommended for continuous service on alkalis above 100 F (38 C) or more than 20% concentrations; nor for fluorine, hydrofluoric acid, water above 200 F (93 C), steam, slurries, or molten metal. Range: 12-1/2 to 1(7 to 1 for 25-inch differential meters). Operational Limits: Maximum Pressure: 300 psig at 100 F (2070 kpa at 38 C) Minimum Temperature: 32 F (0 C) Maximum Temperature: 250 F (121 C) 2

WARNING These meters must not be operated without the shield in place. To do so could result in injury to personnel. CAUTION It is important that the 0 ring material be compatible with the process fluid. Meter tube breakage can occur if the wrong materials is used. For example VITON 0 RINGS MUST NEVER BE USED FOR AMMONIA SERVICE. Capacity The following capacities are offered as a guide only. The values shown are the maximum flow obtainable through a square edge concentric orifice. Span of maximum values shown are those obtainable by varying the main line orifice diameter ratio between 0.3 and 0.7. Range is 12-1/2:1 in all cases except for 25-inch (6.25 kpa) Differential which is 7:1. Nominal Capacity Guide Maximum GPM Water Main Line Maximum Differential Pressure Pipe Size Inches water kpa Inches (mm) 25 (6.25) 50 (12.5) 100 (25) 150 (37.5) 200 (50) 300 (75) 400 (100) 2 (50) 18 42 25 60 25 85 25 100 30 120 30 150 30 170 3 (76) 20 92 25 130 30 180 35 220 40 260 50 320 60 370 4 (102) 25 157 35 200 50 310 62 380 70 450 85 550 100 620 6 (152) 56 360 80 500 115 720 140 860 160 1000 200 1200 260 1400 8 (203) 100 615 140 870 200 1250 240 1500 280 1750 340 2100 400 2500 10 (254) 168 1000 230 1400 300 1950 380 2400 420 2800 510 3400 600 4000 12 (305) 225 1400 310 2000 390 2800 550 3400 630 4000 770 4960 800-5500 To obtain flow in scfm of air at 14.7 psia & 70ºF multiply values in table by 4.12. To obtain flow in m 3 /hr of air 101.4 kpa abs and 21ºC multiply values in table by 7.0. To obtain flow liters/min. of water multiply values in table by 3.785. 3

Typical Installations Typical Orifice Flange Unions (A.G.A. STD) Recommended Installation for Flange Taps Recommended Installation for VENA Contracta Taps (Main LIne 4 (DN100) or Larger) Notes: 1. Use flange or Vena Contracta Taps. Pipe Taps are not recommended. 2. Measure pressure at the downstream tap when required measure temperature 3-5 diameters downstream or 10-15 diameters upstream. 3. When metering liquids, provide air vents at the high points. 4. Lag Oriflowrator meter piping when necessary. 5. All dimensions are in inches; dimensions in parentheses ( ) are in millimeters, unless otherwise specified. TABLE A Pipe sizes for installation of Oriflowrator Meter distance from Orifice is applicable for Flange or Vena Contracta Taps Pipe Size ANSI DIN Allowable Equiv. Length of Oriflowrator Piping 90º EL Equiv. Pipe Length of Fittings, ft. 45º EL Valve Union ½ 15 Up to 10 feet (3m) 1.5 0.8 0.35 0.17 ¾ 20 Up to 20 feet (6m) 2.0 1.0 0.45 0.19 1 25 Up to 60 feet (20m) 2.5 1.2 0.60 0.21 Notes: Keep number of fittings to a minimum. Use necessary reducing fittings at orifice conns. and meter. Pipe to be free of burns, friction losses based on schedule 40 pipe. 4

METER TUBE 1/2 SIZE DIM INCH mm A 19-5/16 490 B 16-1/2 419 C 1-13/32 37 D 3-1/2 89 E 3-3/8 86 F 2-5/8 67 G 8-1/4 210 L 1-1/2 38 M 1-1/4 32 N ½ 13 P ¾ 19 Q ½ 13 METER TUBE 1/2 SIZE DIM INCH mm A 18-9/16 471 B 20-5/8 524 C 2-21/32 68 D 1-5/8 41 E 3-3/8 86 F 2-5/8 67 G 7-21/32 194 L 1-1/2 38 M 1-1/4 32 N ½ 13 P ¾ 19 Q ½ 13 5

For Detailed specifications, refer to Product Specification D-FV-10B4000 Product Code A Base Price includes fittings of material shown, 316 SST float and Range Orifice, percent on Metal Scale, factor tag, Buna "N" O-rings or Neoprene packing with 303 SST packing glands. ALARMS: Price adder includes bracket assembled to meter body, alarm float, amplifying relay and minimum and/or maximum switches with 5.5 feet of lead wire. (Only available for 200 inches of water differential). Code Variable Area Master Ori-Flowmeter Model 10B4000 For quantity greater than 5 call 10B4 1 : Seals O-Ring Pressure 55 Packing Gland Type Pressure 65 2 : Connection Designation 1/2 in. NPT Horizontal 5 1/2 in. NPT Vertical 7 3 : Scale Type Percent on Tube Direct Reading on Tube Direct Reading Metal Scale and Percent on Tube Percent on Metal Scale Direct Reading Metal Scale Dual Direct Reading Metal Scales 4 : Panel Mounting Line Mounted Front Panel Mounted Rear (Flush) Panel Mounted 5 : Design Level B 6 : Connection Size Connector, Size 1/2 In. Tube Size 1/2 In. 7 : Fitting Material AISI 316 SST (1.4401) X Y E P S D X Y Z B H C 8 : Seal Material Packing Gland Design Neoprene (Note: 1) E Packing Gland Design Teflon (Note: 1) D O-Ring Design Buna-N (Note: 2) F O-Ring Design Viton (Not used with Ammonia) (Note: 2) H 9 : Connection Type 1/2 in. NPT B 10 : Alarms Not Required X 11 : Orifice Differential 25 Inches B 50 Inches C 100 Inches D 150 Inches E 200 Inches F 300 Inches G 400 Inches H 6

10B4 Code 12 : Inlet Connection Orientation Front (Note: 3) 1 Back (Note: 3) 2 Right (Note: 3) 3 Left (Note: 3) 4 Bottom Vertical (Note: 4) 5 13 : Outlet Connection Orientation Front (Note: 3) 1 Back (Note: 3) 2 Right (Note: 3) 3 Left (Note: 3) 4 Top Vertical (Note: 4) 5 14 : Float Code 25,50,100,150 Inches H2O; 1/2-GUSVT-413 (Note: 5) 83 200,300,400 Inches H2O; 1/2-GUSVT-414 (Note: 6) 84 15 : Tube Code FP-1/2-27-G-10 A3 16 : Float Material 316 Stainless Steel (standard) 1 Additional Ordering Code 17 : External Needle Valve (316 sst) & Nipple (unassenbled) 1/2 In. NPT; p/n 614C068U03 V3 18 : Certifications Certificate of Conformance; per order 19 : Material Certifications Material Certifications; "typicals", per material 20 : Pressure Test Hydrostatic pressure test; 1/8 In. 1/2 In. diameter 21 : Tags Stainless Steel Tags (wired on) per meter D1 M1 H1 T1 Note 1: Not available with Seals code 55 Note 2: Not available with Seals code 65 Note 3: Not available with Connection Designation code 7 Note 4: Not available with Connection Designation code 5 Note 5: Not available with Orifice Differential code H, G, F Note 6: Not available with Orifice Differential code B, C, D, E 7

Ordering Information To eliminate any delays in the processing of orders and to insure prompt delivery, please specify: Model number Maximum Differential Pressure Main Line Flow Rate Range and Unit of Flow Accuracy desired Materials of Construction (end fittings, O-rings or packing, glands or screws) Options or accessories desired Operating conditions Fluid measured Fluid density or specific gravity Fluid viscosity Operating and maximum temperature Operating and maximum pressure ABB has Sales & Customer Support expertise in over 100 countries worldwide www.abb.com The Company s policy is one of continuous product improvement and the right is reserved to modify the information contained herein without notice. Printed in USA (04.17.09) ABB 2003, 2009 ABB Inc. 125 East County Line Road Warminster, PA 18974 USA Tel: +1 215 674 6000 Fax: +1 215 674 7183 (US) 8