HIGH VOLTAGE MODULE TEST SYSTEM

Similar documents
Impulse Voltage Test System, Q Structure, kV

W SERIES IMPULSE VOLTAGE TEST SYSTEM APPLICATION FEATURES

HV9000 High Voltage Modular Training Set

Current accuracy class. Sensor principles

High Voltage Engineering

B kv Gas-insulated Substations

Outdoor vacuum breaker for railway applications - FSK II

A novel synthetic test system for thyristor level in the converter valve of HVDC power transmission

September 2008 TEC, INTELLIGENT MONITORING SYSTEM

Energy Transmission & Distribution Services - Italy. SVEPPI laboratory...our services for your success. Answers for energy.

Raising the bar. UHV switchgear and components

ELECTRIC MACHINES EUROLAB 0.3 kw

B kv T&D GAS INSULATED SWITCHGEAR

Control System for a Diesel Generator and UPS

Tips & Technology For Bosch business partners

CHAPER 5 POWER FLOW STUDY IN THE INTEGRATED GRID NETWORK

INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement.

CAST RESIN TRANSFORMERS

POWER QUALITY SEMINAR OF IRAN, 2 ND MARCH 2017 Power Quality Seminar. Abel-Zhang,Power Quality Center Manager

Independent Testing Laboratory for High Voltage Equipment

ABB PTTR SPAIN. Zaragoza. The product: Cast coil transformers

List of major equipment in Electrical Enginerring Department Labs

Technical Specifications (In-Cash Procurement)

SolarMax 330TS-SV. The all-round solution for large-scale PV installations.

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,

FALL-OF-POTENTIAL GROUND RESISTANCE TESTER

Advanced Test Equipment Rentals ATEC (2832)

HIGH POWER SOLENOID DRIVER 1

Deutsche Akkreditierungsstelle GmbH

Photovoltaic Solar Energy Modular Trainers

NXPLUS C Single busbar. Maintenance-free for lifetime

1 Low-voltage Power-factor Correction capacitors KNK APPLICATION DESIGN

Table of Contents. 95 IMS 25 flexible manufacturing line with 5 stations. 104 IMS 26 flexible manufacturing line with 6 stations

16kA Solid Dielectric, Triple Option Reclosers Catalog VLT12

OTCF. Grid Solutions. Capacitor Voltage Transformers 72.5 kv to 800 kv. Quality Product Design. Seismic Withstand Capability.

ZF SERIES HV GAS INSULATED SWITCHGEAR (GIS) tgood.com. Energy. Fast.

CAST RESIN DISTRIBUTION TRANSFORMERS 2016 EDITION

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

Motor-Generator and Transformer Construction Application AEL-MGTC

Small wonder. Station service voltage transformers for small power requirements

SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv

Evolution of the standard CISPR25 to the Ed4. Impact on the design of vehicle component chambers and Frankonia solution EDTC

HIGH VOLTAGE SURGE ARRESTER SPECIFICATION

DEPARTMENT OF ELECTRICAL ENGINEERING DIT UNIVERSITY HIGH VOLTAGE ENGINEERING

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

Solid Dielectric, Three Phase Reclosers CATALOG VS11

The comprehensive portfolio of the testing laboratories at Schaltwerk Berlin siemens.com/energy/psw

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

HEIDENHAIN Measuring Technology for the Elevators of the Future TECHNOLOGY REPORT. Traveling Vertically and Horizontally Without a Cable

Table of Contents. Table of Contents UniTrain UniTrain courses UniTrain mechatronic courses IMS 23/24 with 3/4 subsystems

Technical Data. Low Voltage Regulation System LVRSys. Flexible solution for power utilities. Voltage stabilization for industrial grids

PURE PHYSICS ELECTRICITY & MAGNETISM (PART I)

INTRODUCTION. AC motor operations, most widely used motor is three phase induction motor. This type of motor does not require any starting device

Product Overview. Transformers & Reactors. Proficient. Innovative. Customer-orientated. Transformers up to 8MVA AC/DC Reactors up to 3000A

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide

Product catalogue. Power Resistors. variable and fixed resistors wirewound resistor elements steel grid resistors. Power resistors

Transparent and Functional Motors Application AEL-FTM

In any of the 5 star hotels. The exact venue will be informed once finalized.

Voltmeter. for Experiments with the fischertechnik Expansion Kit. Order No

Analog input module. Brief description. Page 1/8. Data Sheet

EPS/ELA-Series User Manual EPS/ELA 250W

Minimum Ignition Energy Test Apparatus for Dust Cloud

Energy Storage and Other Energy Control Solutions

Power System Solutions (PSS)

Power Management in a Green Factory. March 20, 2013 Mike Lin Delta Products Corp.

3TM Vacuum Contactors

WELCOME! Today we d like to Introduce you to your North American Rotary UPS Solutions Partner!

More Precision. mainsensor Magneto-inductive displacement sensor

CTT & WPU CABLE TEST TERMINATIONS & WATER PROCESSING UNIT. H I G H V O LTA G E TEST SOLUTIONS

ES09 ELECTRICAL MACHINES TECHNICAL SPECIFICATIONS

Solid Dielectric, Single Phase Recloser

HIGH POWER RECTIFIER SYSTEMS

Q pole Pole Mounted Capacitor System

UNIT 4 IGNITION SYSTEMS

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

NZQA registered unit standard version 3 Page 1 of 5. Demonstrate and apply knowledge of electrical machines

Design and Reliability of a High Voltage, high Current Solid State Switch for Magnetic Forming Applications

SF6 free high-voltage GIS installation in Zürich, CH.

P2 : About Us. P3 : Elsewedy Transformers. P4 : Why Elsewedy Dry Type Transformer? P6 : Cast Resin Dry Transformers. P7 : Technical Data Sheets

1ZSE en, Rev. 7. Transformer bushings, type GOB Technical guide

Power Voltage Transformers for Air Insulated Substations

SWITCHGEAR FOR SERVICE UP TO 36kV (CABLE AND OVERHEAD CONDUCTOR CONNECTED)

INTELLIGENT FLANGE STRÖTER. Magnetic pulse generator

MECHATRONICS LAB MANUAL

DELTA4000 Accessories

Safety Sensor CSS 180 Product Information

Chapter 1: Battery management: State of charge

White Paper. Application of Resistive/Reactive Load Banks for kva Testing

ENGINEERED TO ORDER SOLUTIONS

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

SF 6 Gas Insulated Switchgear Type SDH314 / SDHa314 for 72.5 to 145 kv

ADVISE DESIGN IMPLEMENT FOR ELECTROTECHNICAL EXCELLENCE

Grounding systems for power supply facilities

Electronic Ballast EVG 2000-T

High Voltage and Extra High Voltage Cables

Thermal Overcurrent Circuit Breaker 3120-F...

Modernisation of a Bucket-Wheel Excavator at the Welzow-South lignite mine, Lausitzer Braunkohle AG, Germany (1996)

Schedules 1 to 4, Lot B: Extension of the Lessos Substation

Switchgear Type SIMOSEC, up to 24 kv, Air-Insulated, Extendable

Brake Pack SB50W. Standard AC Motors A-143. Standard AC Motors Intro duction. Brake Pack. AC Speed Control Motors Inverter.

Transcription:

HIGH VOLTAGE MODULE TEST SYSTEM 4.0/4 Module Test Systems n AC, DC, and impulse testing n Factory testing n R&D n Education / training

MODULES FOR VOLTAGE GENERATION Test transformers for 100 and 200 kv The oil-insulated transformer T 100 is built in an insulating, fibreglass reinforced tube with steel covers. Two transformers T 100 can be switched in series to the cascade type T 200 for 200 kv. The transformer is designed for continuous power of 6.6 kva and 11 kva for one hour per day. HV capacitors for 100 kv AC/135 kv DC The capacitors C 01 to C 10 (0.1 to 10 nf) of liquid-impregnated foil-paper insulation are used for voltage measurement, PD coupling, DC and impulse voltage generation. HV resistors for 140 kv The resistors R 025 to R 5000 (0.25 to 5000 kω) are used for impulse generation, current limitation, protection or discharging. HV blocking impedance for 150 kv The HV impedance is used for sensitive PD-measurements. HV rectifier for 135 kv DC The rectifier G 270 is designed for a reverse voltage of 270 kv which is necessary for the generation of 135 kv DC voltage. For quick and convenient polarity reversal, the rectifier element can be simply turned within a casing. Spark gaps for 100 kv AC/135 kv DC The two spheres of the spark gap are arranged in an insulating frame. The spark gap is available as a motor driven type TF and alternatively as a manually adjusted type VF. Both units are used as a trigger spark gap for impulse voltage generation. They are equipped with a trigger generator. The drive (Type TF) and the trigger generator are controlled via fibre-optic links. Compressed-gas capacitor for 100 kv AC A standard capacitor MCP 100 with a capacitance of 100 pf is applied for precise voltage and dielectric loss measurements. It is filled with SF of a pressure of 4 bar. 6 Divider resistor for 135 kv DC The resistor MR 250 (250 MΩ) is designed for resistive voltage dividers for 135 kv, 270 kv (two in series) and 350 kv (three in series). The dividers MRT 250, MRT 500 und MRT 750 are completed by the LV measuring branch, a base element FE 1 and the junction element KE.

MECHANICAL MODULES Junction element The junction element KE is a PD-free polygon electrode of six plates that are screwed into an internal cross. The KE 1 with plates of 125 mm diameter can be used up to 240 kv peak. For higher voltages up to 350 kv peak, the KE 2 with 250 mm plates are available. The components are connected to the junction elements by bolted connections. Insulating and connecting elements The insulating element IE serves as a support insulator (up to 140 kv peak) or a spacer (up to 270 kv peak). The connecting element VE is an electrical connection. Both functions can be performed by the combined insulating/connecting element VES, which is installed on an insulating frame where a connecting element can be plugged in or removed. Base and base connecting elements Base elements (FE 1) and base connecting elements (FV 1) ensure the stable assembly of the modules and the reliable earthing of the HV circuit. An additional LV measuring branch MC including cable connection can be fixed on the base element. Elements for earthing and discharge Earthing rods ES are available for voltages up to 200 kv AC. For discharging capacitors the rods ERS are completed by a resistor applicable up to 350 kv DC. For automatic or damped earthing up to 150 kv peak, magneticdriven earthing devices (EE 150, ERE 150) are available. They are equipped with an electric magnet that is actuated by the control. The magnet is switched on for de-earthing, but for earthing it is switched off and the rod moves into the correct position by the gravity. Storage trolley The trolley LW is intended to store up to six HV modules that are not in use in the HV test circuit.

HIGH VOLTAGE MODULE TEST SYSTEM Fig. 1 Combined AC, DC, and impulse test system, type WGSBS 5.8/100-135-135, 100 kv AC, 135 kv DC, 135 kv impulse voltage facts IN BRIEF The high voltage module test system is able to generate AC, DC, and impulse test voltages up to 200 kv AC, 350 kv DC, 110 kv LI, and 100 kv SI. The test system has a modular design. Its main component is a 100 kv AC test system. It can effortlessly be extended by additional components for higher AC voltages or even different voltage shapes such as DC or impulse. The rearrangement of the test system, for example from AC testing to impulse testing, requires only minimal adjustments without special training. Due to its modular design and high flexibility it is not only widely used for factory and on-site testing of components in distribution networks, but also for research, development, training, and education. The core of the control of the HV module test system is the industrially proven SIMATIC S7. Even the basic control enables operators to flexibly operate the test system manually and it allows a simple automatic operation of the test system. It can be improved by a computer control that allows automatic testing, easy data handling, and reporting. Furthermore, additional measuring devices such as for PD measurement can easily be implemented in this control. BENEFITS n EASY HANDLING n WIDE RANGE OF APPLICATIONS FROM FACTORY TESTING TO R&D n MANY TEST ARRANGEMENTS AS FOR AC, DC, AND IMPULSE VOLTAGEs n FAST REARRANGEMENT WITHOUT SPECIAL SKILLS

Impulse alternative 3 4 5 6 7 8 9 1 2 DC 3 5 6 Test Object 11 AC 10 Test Object 11 13 1234 U 15 17 16 Fig. 2 Block diagram for different test set ups as AC, DC, and impulse testing Application The high voltage module test system allows a wide range of applications, e.g.: Training Education Diagnostic on-site testing Research works Development Factory testing of equipment for the distribution network The basic control SIMATIC S7 is sufficient for simple applications as pure voltage measurement. In case of frequent measurements or combined measurements of voltage and PD, we recommend using a computer control. It offers a variety of advantages as semi- or fully-automatic testing even of advanced test sequences, data storage, and report generation. In R&D, where very often a large number of tests with specific conditions and subsequent statistical evaluations have to be performed, the HV module test system is your first choice. The advantages of the simple and modular design will stand out especially during training and education. The easy modification, which can be done without special skills, and the easy operation of the test system result in an effective training approach. n STANDARDIZED COMPONENT GRID DIMENSIONS n OPTIONAL COMPUTER CONTROL FOR FAST AND FULLy-AUTOMATIC TESTING n OPTIONAL INTEGRATION OF OTHER MEASUREMENT SYSTEMs ( FOR PD MEASUREMENTS )

Power supply 10 Test Object 11 1 2 Power module HV circuit Transformer 3 Rectifier 4 Charging resistor 5 Charging capacitor 6 Resistive voltage divider 12 7 8 Trigger spark gap Damping resistor 9 Impulse capacitance 10 Capacitive voltage divider 12 Impulse current shunt Control system 13 Operator panel, PLC 14 Remote access module 15 Industrial PC 1234 MiAS 18 16 17 18 Bus system/control cables Measuring system AC/DC peak voltmeter Transient measuring system 14 Power connections Communication / measurement 11 Transformers, bushings, cables etc. System and components The HV module test system is charged and controlled by a power module (1). It can be connected to a simple 230 V CE socket. The power module regulates the output voltage and is directly connected to the HV transformer (2). Power module and HV transformer are the basic components for each set up. All other components depend on the final test configuration as AC, DC, or impulse testing (Fig. 2). The HV components of the module test system have a standardized length to ensure a fast and easy rearrangement of the test set up. This fixed distance can easily be kept by the base elements which have exactly the same dimension. The HV components can be flexibly arranged in a linear as well in a rectangular shape (Fig.1). Individual components of the module test system are effortlessly connected via junction elements. The junction element is designed as a polygon electrode. The interconnection between the HV components and the junction elements is realized by union nuts fixed by hand. This results in a much more stable arrangement in comparison to other solutions such as plug-in. The base elements will carry the low voltage measuring branches or connection boxes for measuring cables. An interconnection of all base elements and its connection to a single earthing point will result in low inductive earthing for the complete HV module test system. A save and easy operation of the HV module test system is ensured by the use of the basic control which is based on programmable logic controllers (PLC), type SIMATIC S7 (13). It is connected via fibre-optic cables to avoid electromagnetic interferences. Optionally the basic control can be improved by a computer control (15). This computer control allows beside advanced testing and reporting also remote diagnosis (14). The voltage is measured by individual dividers for AC (10), DC (6), and impulse voltage (10). The corresponding AC/DC peak voltmeter (17) is arranged in the power module. For impulse measurement a transient measuring system (18) is integrated.

MODULES FOR CONTROL Operator device The operator device BG is the interface between the operator and the test system. The BG contains the operator panel that is connected by fibre-optic ETHERNET to the PLC control mainly arranged in the power module (see below). The control enables manual and simple automatic test procedures. The corresponding status messages are indicated on the display. Most operator functions, such as pre-selection of the test voltage, are implemented by soft keys. The operator device can be delivered as a single unit in a case or as plug-in device for a rack or desk. Power module including peak voltmeter The power module LM is available for continuous power of 5.8 and 11 kva, corresponding to 25 and 48 A at 230 V. Both types contain a regulating transformer that is PLCcontrolled. The PLCs are connected by fibre-optic ETH- ERNET to the operator device and controlled from there. An integral part of the power module is the AC/DC peak voltmeter MU. The measured voltages are displayed on the operator device (see above). The power module has to be completed by the extension unit LMO for impulse voltage generation. The power module (rear view in the picture) can be arranged in the control room or within the HV test area. Computer control and measuring systems The manual or simple automatic control by the operator device can be completed by an industrial PC to a computer control and measuring system CMS to allow fullyautomatic operation. This control can be expanded by a partial discharge measuring system or for impulse voltage measurement by a digital impulse analyzer. Both control and measurement can be handled via the industrial PC. All preselected parameters and measured values are stored by the computer for further processing and test reports. The computer control can also be connected to the computer network (LAN) and for remote service, software updates, etc. via Internet to the HIGHVOLT Service Center. The computer control and measuring system can be supplied as a unit for rack or desk installation. INSTRUCTION FOR HV EXPERIMENTS The HV module system is very well suited for student training and is already considered an essential part of teaching HV engineering at universities, technical institutes, and professional schools. HIGHVOLT is ready to offer consultancy for the layout of laboratories and can deliver shielding systems.

HIGH VOLTAGE MODULE TEST SYSTEM TECHNICAL PARAMETERS The HV modules allow the construction of the following standard HV test systems: Alternating voltages, type WBS (Data Sheet 4.01) (1-stage) (2-stage) Rated AC voltage 100 kv 200 kv Rated power continuous 5.8 kva 5.8 kva Rated power short time (1 h ON/23 h OFF) 11 kva 11 kva Remark: All test system versions are available with circuit for PD measurement and/or C-/tanδ measurement also. Direct voltage, type GBS (Data Sheet 4.02) (1-stage) (2-stage) (3-stage) Rated AC voltage 135 kv 270 kv 350 kv Rated DC current 14 ma 10 ma 8 ma Remark: The test system version 135 kv/14 ma is available with circuit for PD measurement also. Alternating and direct voltage, type WGBS (Data Sheet 4.03) (1-stage) (2-stage) (3-stage) Rated AC voltage 100 kv 200 kv Rated power continuous 5.8 kva 5.8 kva Rated power short time (1 h ON/23 h OFF) 11 kva 11 kva Rated DC voltage 135 kv 270 kv 350 kv Rated DC current 14 ma 10 ma 8 ma Impulse voltages, type SBS (Data Sheet 4.04) Rated charging voltage Rated energy Output lightning impulse voltage (at no-load) 135 kv 100 J 110 kv LI Output switching impulse voltage (at no-load) 100 kv SI Remark: This system is mainly for demonstrations in student s training. For higher voltages and energies, as necessary for real testing and research work the HIGHVOLT series L of impulse voltage test systems is recommended for both, technical and economic reasons. AC, DC and impulse voltages, type WGSBS (Data Sheet 4.08) (1-stage) (2-stage) (3-stage) Rated AC voltage 100 kv 200 kv Rated power continuous 5.8 kva 5.8 kva Rated power short time (1 h ON/23 h OFF) 11 kva 11 kva Rated DC voltage 135 kv 270 kv 350 kv Rated DC current 14 ma 10 ma 8 ma Rated charging voltage Rated energy Output lightning impulse voltage (at no-load) 135 kv 100 J 110 kv LI Output switching impulse voltage (at no-load) 100 kv SI Remark: This universal system is especially designed for student s training and well introduced to the practice of universities and technical institutes. For further information please contact: HIGHVOLT Prüftechnik Dresden GmbH Marie-Curie-Straße 10 01139 Dresden Germany Phone +49 351 8425-700 Fax +49 351 8425-679 E-mail sales@highvolt.de Web www.highvolt.de HIGHVOLT Prüftechnik Dresden GmbH 2012/08 4.03/4.pdf Subject to change without prior notice