Vortex Eggs Delta Flowmeter

Similar documents
/OVAL OPERATION MANUAL. Eggs DELTA Pulse. Vortex Flow Monitor MODEL : FLP? L A G 1 2 FLP? L?

F-2500 SERIES VORTEX METER

Armstrong In-Line and Insertion Vortex Flow Meters

F-2600 SERIES INLINE VORTEX FLOW METER

F-2700 SERIES INSERTION VORTEX FLOW METER

F-2700 SERIES INSERTION VORTEX FLOW METER

VORTEX IN-LINE FLOW METERS

SIGNET 7002 Vortex Flow Sensor ENGLISH

Vortex In Line Flow Meter

F-2600 SERIES INLINE VORTEX FLOW METER

VIM20 Vortex Insertion Flowmeter

Multivariable Vortex Flow Meter

Vortex In Line Flow Meter

VORTEX FLOW METTER DVH. Despriction. Advantages of the DVH Vortex Flow Meter

VLM20 In-line Vortex Flowmeter

The readings you need, right where you need them. AX Series Vortex Meters

Multivariable Vortex Flow Meter

Pro-V Multivariable Flowmeter Model M24 In-line Vortex

Vortex Flow Meter Model DVH

Signet 7000/7001 Vortex Flow Sensors * *

Features/Benefits INSTALL IT & FORGET IT FEATURES & BENEFITS

Digital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series

Vortex Flowmeter Model DVE

Model 5000 Vortex Meter

The readings you need, right where you need them. AX Series Vortex Meters

Series 8000 Vortex Flow Meter

VIM20 Vortex Insertion Flowmeter

Hydro-Flow Model 2300 Installation and Operation Guide B

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

F-1500 SERIES INSERTION TURBINE FLOW METER

VIM20 Vortex Insertion Flowmeter

RCM - Direct Reading Flowmeters

Hydro-Flow Model 3100

Model 1000 Vortex Meter

KDM ARMORED FLOW METER & SWITCH

SIGNET Vortex Flow Sensors ENGLISH

DVH. Vortex Flowmeter. Measuring range: Nm³/h. Accuracy: ± 0,7% of reading (liquids) ± 1% of reading (gases and steam) p max

Hydro-Flow Model 3100 Retractable Insertion Vortex Flowmeter Installation and Operation Manual

Accurate measurement of compressed air consumption and detection of leaks. Measuring the individual consumption per customer / cost centre

G2 Industrial Grade Meters

Hot Tap Insertion Vortex

Satellite photo of cloud vortices caused by a mountain (Courtesy of our friends at NASA) tekvorx Operation Showing Simplified Construction

PanaFlow MV80. In-line Multivariable Flowmeter for Mass, Temperature, and Pressure. GE Sensing. Applications. Key Benefits

Hydro-Flow Model 2200 Fixed Insertion Vortex Flowmeter Installation and Operation Manual

MODEL 106F TEFLON LIQUID FLOW SENSOR

SITRANS FX300 4/289. System Overview. Overview

Inline Flow meter for compressed air and gases DN15 (1/2 ) - DN80 (3 )

Hydro-Flow Model 2200 Installation and Operation Guide B

Innova-Mass Model 240 & 241. Multivariable Mass Vortex Flow Meter. For information online...

To avoid injury, death of personnel ordamage to instrument, the operator must refer to an explanation in the User smanual.

Hydro-Flow 2200 Fixed Insertion Vortex Flow Meter

mass flowmeter for compressed air

MEMFlo MFTV METAL BODIED FLOW METER WITH CLEAR TOP

mass flowmeter for compressed air

HLX771/772. Inline Flowmeter for compressed air and gases DN15 (1/2 ) - DN80 (3 ) Typical Applications

Vortex Flowmeters VFM 3100 F-T VFM 3100 W-T

Low Profile Insertion Vortex

Digital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series. Bulletin 01F06A02-00E.

Hydro-Flow 2300 Fixed Insertion Vortex Flow Meter

imag 4700 SERIES FLANGED MAGMETER

Flow Measurement & Control Solutions

InnovaMass 240 & 241. Multivariable Mass Vortex Flow Meter. FEATURES DESCRIPTION

VFM4070C SWIRLMAX. Vortex Flowmeter OUTLINE FEATURES OPERATING PRINCIPLE STANDARED SPECIFICATION. General Specification. Sensor Specification

FLOW METER ULTRASONIC-VOLTEX FLOW METER ASUSV SERIES IMPELLER FLOW METER ASIP80 SERIES IMPELLER FLOW METER ASSPX SERIES

RCM. Direct Reading Flowmeter. for Liquids or Gases

SITRANS F flowmeters SITRANS F US. SITRANS FUT1010 Ultrasonic flowmeter. Overview. Application

Transmitting Transducer. Gas/Air Velocity Range:

BYPASS ROTAMETERS FOR MEASURING RATE OF FLOW IN LARGE PIPELINES

OMP POSITIVE DISPLACEMENT FLOWMETERS

Fundamental Training. Flow Con t

Vortex Flowmeter. digitalyewflo. Vortex Flowmeter. Series. Bulletin 01F06A02-00E.

Weather-Proof Thermal Mass Flow Meter for Pipe - Duct

RIM20 Rotor Insertion Flowmeter

BI-DIRECTIONAL INSERTION FLOW TRANSDUCER

DW PADDLE-BELLOWS FLOWMETER & SWITCH

Principle of Operation

Signet 2536 Rotor-X Paddlewheel Flow Sensors

VersaFlow Vortex 100 Vortex Flow Meter Specifications

Appendix. Clearance. Skewed profiles. Application Schematics

Vortex Plate. Model VP General Specification. Product Features

DW PADDLE-BELLOWS FLOWMETER & SWITCH

Positive displacement flowmeter for continuous flow measurement

SITRANS F X SITRANS FX300 3/355

ISTEC MAGNETIC METERS

METAL VAREA-METER STRAIGHT THROUGH TYPE ROTAMETER

CATALOG KVFN. Vortex Flowmeter

Model Q45H/ Residual Chlorine Monitor...

CATALOG KVFN. Vortex Flowmeter

Insertion turbine INSTRUCTION SHEET. TECHNICAL PRODUCT

display on the wall or in a panel away from the inline sensor SE30 for easy meter reading.

SMARTLINK METER. Digital Self-checking Thermal Mass Flow Meter

DW PADDLE-BELLOWS FLOWMETER & SWITCH

LTX RF LEVEL SENSOR. Instruction Manual

Excellent Vortex Flowmeter INSERTION Type SMART EX DELTA

Product Data Sheet. VN2000 Flow Meters. Wafer Plate Inline Meter DESCRIPTION BENEFITS OPERATION APPLICATIONS SIZING SOFTWARE

OMP Positive Displacement Flowmeters

Mobrey 003 Ultrasonic Liquid Level Switch

The Polaris MA1 is the first liquid flow meter offered by Magnetrol, expanding the already diverse level and flow measurement portfolio that has been

Electromagnetic Flowmeters. Product Overview.

Model DFX Doppler ultrasonic flow meter

Transcription:

Product Data Sheet PDS-FLM Vortex Eggs Delta Flowmeter Technical Specifications (Liquid, Gas & Air) Easy to read Free positioning EEPROM DESCRIPTION The unique sensor body and transmitter design makes Eggs DELTA one of the most compact, light weight vortex meters in the industry. The injection molded design provides a smooth surface for cleanliness and better chemical compatibility. It is an ideal measurement and monitoring device for most gases, liquids and air applications. PRINCIPLE OF OPERATION The Eggs DELTA measures flow rate based on Karman's vortex shedding principle. The stationary trapezoidal object (bluff body) placed into the path of the flow stream sheds vortices downstream at a frequency proportional to the velocity of flowing media. A piezoelectric sensor detects the vortices and creates electrical impulse signals which is proportional to the fluid flow rate. APPLICATIONS The simple unique construction without any moving parts enables Eggs DELTA to measure liquid, air and gas flow measurements with very little head loss. Common applications include: deionized water (RO/DI skids) ultra pure water distribution in medicare, biotech, semiconductor and pharmaceutical market segment chemical feed air consumption control in compressed air distribution systems gas flow (nitrogen, oxygen, argon, etc) measurements and monitoring. sanitary cleaning process flow cooling water (PPS) polyphenylene sulphide material is compatible with nearly all gases & liquids Sparling/Oval Eggs Delta is manufactured by Oval Corporation in Japan. /OVAL

STANDARD FEATURES Sizes include1/8", 1/4", 1/2" and 1" with injection molded plastic construction. Single molded one-piece meter and bluff body construction with no moving parts. Instantaneous flow rate totalizer. NEMA-4X enclosure. Optional 4-20mA or pulse output with external power. Each unit is battery powered, which eliminates the need of an external power source and saves wiring and installation cost. The meter will provide a low battery display in case meter needs battery replacement. Unique coupling design allows "Free Positioning" of the transmitter for ease of reading regardless of meter body orientation. Each meter has built in EEPROM which stores meter parameters and totalizer reading. Two separate totalizers with one reset switch keeps the count of individual readings. Two separate indicators display the flow rates in GPM and GPH as required. GENERAL SPECIFICATIONS Accuracy: Repeatability: Process Fluid: Ambient Temp: Max. Operating Pressure: Flow Ranges: ± 1% full scale on 1/2" & 1" (liquid only) ± 3% full scale ±.5% full scale -4 o F to +176 o F -4 o F to +140 o F 150 psi See Tables Pressure Loss: Water:.05-4.56 (1/8"), (PSI).018-5.04 (1/4" - 1") Air:.02-0.103 (1/8"),.009-0.22 (1/4" - 1") Construction Material: PPS (Polyphenylene sulphide) Display: 8 digit totalizer with two separate 4 digit indicators showing flow rate per hour and minute HOW TO ORDER EGGS DELTA Base Model Number FLM Eggs DELTA Applicable Fluids 2 Liquid 3 Gas Size S 1/8" (4mm) 0 1/4" (8mm) 1 1/2" (15mm) 2 1" (25mm) Indicator 1 with indicator/totalizer Output 0 None (battery drive) 1 Factored pulse 2 Analog (4-20mA on full scale) Construction W NEMA-4X Output: 4-20mA output: Scaled electronic Pulse: Power: External Power Supply: Enclosure rating: Process: Connections: 7 digit reset totalizer True two wire requiring external power supply - 12-45 VDC(Use 4 conductor shielded cable) Three wire system requiring external power supply Pulse width: 30 ms Allowable max. current: 20 ma Max. voltage impressed: 30V Battery (3.6V lithium) powered if no output (other than display of rate or totalizer) is required (4 years of life at room temperature, also provide power reduction alarm) 12-45 VDC required for 4-20mA or scaled pulse output NEMA-4X NPT threaded adapters: R 3/8-19...1/8" NPT female R 1/2-14...1/4" NPT female R 3/4-14...1/2" NPT female R1 1/4-11...1" NPT female Accessories NPT Threaded Adapters (PVC) NPT Threaded Adapters (PPS) FLM --

FLOW RANGES Table 1 - Liquids (gallons per minute) Model # Flow Totalizer Min. Max. Size Indicator Rate (scaled pulse output) Flow (4mA) Flow (20mA) 1/8" (4mm) FLM2S x.01 gpm x.01 gallons.105 1.05 1/4" (8mm) FLM20 x.01 gpm x.01 gallons.31 3.96 1/2" (15mm) FLM21 x 0.1 gpm x 0.1 gallons.75 11.44 1" (25mm) FLM22 x 1 gpm x 1 gallon 2.20 35.14 Above table is based on water measurements at 70 o F measurement Table 2 - Air / Gas (standard cubic feet per minute) Model # Flow Totalizer Min. Max. Size Indicator Rate (scaled pulse output) Flow (4mA) Flow (20mA) 1/8" (4mm) FLM3S x.01 scfm x.001 scf.254.59 1/4" (8mm) FLM30 x 0.1 scfm x.01 scf.65 3.178 1/2" (15mm) FLM31 x 1 scfm x 0.1 scf 1.94 8.994 1" (25mm) FLM32 x 1 scfm x 1 scf 5.9 30.176 Above table is based on air measurements at 68 o F and atmospheric pressure (14.7 psia) Flow range may vary under different process conditions such as density and viscosity of the process fluid. Meter L W H1 H2 *L H Model Size I.D. in. in. in. in. in. in. FLM_S 1/8" (4mm) 4mm 3.15 1.26 1.14 4.02 5.12.57 FLM_0 1/4" (8mm) 8mm 3.15 1.26 1.14 4.02 5.12.57 FLM_1 1/2" (15mm) 14mm 3.35 1.26 1.14 4.02 5.12.57 FLM_2 1" (25mm) 24.5mm 4.72 1.81 1.81 4.69 7.48.906 *L = with adapters

EGGS DELTA-PULSE TYPE NEW REYNOLD'S NUMBER A Reynolds Number is a dimensionless number used to determine the effects of viscosity, specific gravity and velocity on flow sensor performance. To maintain system accuracy, a Reynold's Number greater than 3,000 is required. N R = Reynold's Number: N R = V x D S V - velocity in ft./sec. D - inside diamedter (in ft.) S - kinematic viscosity in centistoke Applications: liquid, gas & air Sizes: 1/8", 1/4", 1/2" and 1" Temp. Range: -4 o F to +140 o F Accuracy: ±3% of full scale Power:12-45 VDC Eggs Delta-Pulse is a light weight, small, low cost flow monitoring vortex meter made out of PPS resin. Its simple design and material makes it suitable for a wide variety of flow applications. It has no moving parts and the injection molded design provides a smooth surface for cleanliness and better chemical compatibility. (Ask for PDS-FLP for specifications) EX DELTA SERIES Smart EX DELTA WAFER OR FLANGED WITH FIXED OR REPLACEABLE SENSOR Smart EX DELTA INSERTION TYPE Applications: gas, steam, air or liquid Sizes: 1/2"- 6" (wafer), 2"-12" (flanged with fixed or replaceable sensor) 150 & 300 psi Temp. Range: max 788 o F Accuracy: ±1% of rate Power: battery powered with no outputs or 12-45 VDC with 4-20mA or pulse Rugged yet simple construction in wafer or flanged end connections with fixed or replaceable sensor. Unique bluff body design with piezo-electric sensor has no moving parts and provides complete isolation of sensor from process fluid. Unit is available as loop powered for different outputs or battery powered with local display of rate or totalization. The EX DELTA DIA is also available for dirty liquid applications where sensor is located apart from the bluff body for isolation from any build up. Applications: gas, steam & liquid Sizes: 8" - 80" (fixed type) & 16" - 80" (hot tap type) Temp. Range: -14 o F to 572 o F Accuracy: ±2% of full scale Power: battery powered with no outputs or 12-45 VDC with 4-20mA or pulse Insertion vortex meters are a low cost alternative to in-line flow meters. The probe with a piezo-electric sensor and bluff body is inserted in the pipeline and detects the velocity in the line to obtain a total flow rate. Sparling not only offers fixed type, but hot tap type installation where in-line measurements of a continuous vital process where the where the flow cannot be interrupted. 4097 N. Temple City Blvd. P.O. Box 5988 El Monte, CA USA 91731 Ph (626) 444-0571 Fx (626) 444-2314 Internet: http://www.sparlinginstruments.com E-mail: sales@sparlinginstruments.com 05/01 Printed in U.S.A. 2001 Sparling Instruments, Inc. All rights reserved PDS-FLM

Vortex Eggs Delta-Pulse Flowmeter Technical Specifications DESCRIPTION Eggs Delta-Pulse is a light weight, small, low cost flow monitoring vortex meter made out of PPS resin. Its simple design and material makes it suitable for a wide variety of flow applications. It has no moving parts and the injection molded design provides a smooth surface for cleanliness and better chemical compatibility. (Liquid, Gas & Air) APPLICATIONS (PPS) polyphenylene sulphide material is compatible with nearly all gases & liquids. Common applications include: deionized water (RO/DI skids) ultra pure water distribution in medicare, biotech, semiconductor and pharmaceutical market segment cooling water chemical feed alcohol air consumption control in compressed air distribution systems gas flow (nitrogen, oxygen, argon, etc) measurements and monitoring. sanitary cleaning process flow PRINCIPLE OF OPERATION The Eggs DELTA measures flow rate based on Karman's vortex shedding principle. The stationary trapezoidal object (bluff body) placed into the path of the flow stream sheds vortices downstream at a frequency proportional to the velocity of flowing media. A piezoelectric sensor detects the vortices and creates electrical impulse signals which is proportional to the fluid flow rate. Sparling/Oval Eggs Delta is manufactured by Oval Corporation in Japan. STANDARD FEATURES Sizes include1/8", 1/4", 1/2" and 1" with injection molded plastic construction. Single molded one-piece meter and bluff body construction with no moving parts. NEMA-4X enclosure. Open collector unsealed pulse output with 12-24 VDC loop power. NPT threaded connection for simple installation. GENERAL SPECIFICATIONS Accuracy: ±1% full scale on 1/2" & 1" (liquid only) ±3% full scale Repeatability: +/-.5% full scale Process Fluid: -4 o F to +176 o F Ambient Temp: -4 o F to +140 o F Max. Operating Pressure: 150 psi Flow Ranges: See Table Pressure Loss: Water:.05-4.56 (1/8"), (PSI).018-5.04 (1/4" - 1") Air:.02-0.103 (1/8"),.009-0.22 (1/4" - 1") Construction Material: PPS (Polyphenylene sulphide) Output: Open collector unscaled pulse Max 30 VDC, allowable current: 20mA Pulse width duty 1:1 Cable: 3 cores shield cable (3 ft.std.) Transmission Length:3,280 feet Power Supply: 12-24 VDC Enclosure rating: NEMA-4X Process Connections: NPT threaded adapters: R 3/8-19...1/8" NPT female R 1/2-14...1/4" NPT female R 3/4-14...1/2" NPT female R1 1/4-11...1 1/4" NPT female /OVAL

FLOW RANGES Factored Pulse Max Frequency Liquid Flow Gas Flow Size Units pulse units (Hz) (gpm) (scfm) (ml/pulse) Liquid Gas Min. Max. Min. Max. 1/8" (4mm) 0.0890 749 3180.105 1.1.254.59 1/4" (8mm) 0.441 567 3400.31 4.0.65 3.2 1/2" (15mm) 2.36 306 2000.75 11.4 1.9 8.9 1" (25mm) 12.7 175 1120 2.2 35.1 5.9 30.2 1 ml = 2.642 x 10-5 gal. Above table is based on water measurements at 70 o F measurement Above table is based on air measurements at 68 o F and atmospheric pressure (14.7 psia) Flow range may vary under different process conditions such as density and viscosity of the process fluid. HOW TO ORDER EGGS DELTA PULSE Base Model Number FLP Eggs DELTA-Pulse Size 04 1/8" (4mm) 08 1/4" (8mm) 15 1/2" (15mm) 25 1" (25mm) Applicable Fluids G Gas L Liquid Frequency Division 1 1/1: Liquid (always "1") 2 1/10: Gas (always "2") Material for Connection Adapters P NPT Threaded Adapters (PPS) V NPT Threaded Adapters (PVC) Version A Always "A" FLP A Meter L W H1 H2 *L H Size I.D. in. in. in. in. in. in. 1/8" (4mm) 4mm 3.15 1.26 1.14 2.7 5.12.57 1/4" (8mm) 8mm 3.15 1.26 1.14 2.7 5.12.57 1/2" (15mm) 15mm 3.35 1.26 1.14 2.7 5.12.57 1" (25mm) 25mm 4.72 1.81 1.81 3.3 7.48.906 *L = with adapters 4097 N. Temple City Blvd. P.O. Box 5988 El Monte, CA USA 91731 Ph (626) 444-0571 Fx (626) 444-2314 Internet: http://www.sparlinginstruments.com E-mail: sales@sparlinginstruments.com 05/01 Printed in U.S.A. 2001 Sparling Instruments, Inc. All rights reserved PDS-FLP