Centrifugal Separator Operations & Maintenance Manual

Similar documents
Separator Systems Operations & Maintenance Manual

Corrosion Coupon Rack Operations & Maintenance Manual

Bypass / Filter Feeders Operations & Maintenance Manual

Industrial Gly-Pack Feed Systems Operations & Maintenance Manual

GLYCOL FEED SYSTEMS OPERATION & MAINTENANCE MANUAL

CT SEPARATOR SYSTEM OPERATION & MAINTENANCE MANUAL

COMPACT GLYCOL FEED SYSTEMS OPERATION & MAINTENANCE MANUAL

SEPARATOR PURGE KIT OPERATION & MAINTENANCE MANUAL

SAMPLE COOLER and SLUDGE TRAP OPERATION & MAINTENANCE MANUAL

GENERAL PURPOSE MIXERS

Corrosion Coupon Rack

HTX-HTH SEPARATORS I&O MANUAL

CHEM-FEED. Engineered Skid Systems. ProSeries. by Blue-White Ind.

Electric Reciprocating Compressor. Installation Guide

Enclosed Electric Rotary Screw Compressor Installation Guide

Manual. Economy Glycol Feeder. Installation Maintenance Repair Manual

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

GLOBE FLOWCELL. Operating Manual. Rola-Chem Flowcell PN /01/2013 page: 1 of 8

MicroTron Series C. Manual. Installation Maintenance Repair. Manual. Chemical Metering Pump

Fluid Coil Installation, Operation and Maintenance

Wastewater Combination Air Valve. Operation, Maintenance and Installation Manual

Mini Pure. User Manual. Model Number:

QUALITY MISTING PUMPS

6. Electrical. 7. Settings. 8. Quick

DUST COLLECTOR (BOTTOM REMOVAL BAG & CAGE) INSTALLATION AND OPERATING INSTRUCTIONS

SUMMIT PUMP Horizontal End Suction Pump Close Coupled and Frame Mounted

65 Series. Valve Operation Manual

VSP SERIES Installation, Operation and Maintenance Manual

QPET, QPETXU Battery Chargers

OWNER S MANUAL. Model: SK-61-4R ( ) (60 Gallon Skid Sprayer w/5.5 HP Engine, 4-Roller Pump & Deluxe Handgun) Assembly Instructions

INSTRUCTION MANUAL G-Surge Tank #40007, #40008 & #40009

Manual. MicroTron. Series C. Installation Maintenance Repair Manual. Chemical Metering Pump

Ford Meter Box Test Bench Installation Instructions

Val-Matic Air / Oil Hydraulic Panel Pump Control System. Operation, Maintenance and Installation Manual

Instruction Manual. Series R Peristaltic Pump. For file reference, please record the following data:

VEGETABLE OIL DISPOSAL UNIT (MSDU) OPERATOR & SERVICE MANUAL

General Installation Instructions for Valves and Gates

2460 / 2472 / Series Simplex Grinder Systems

OWNER S TECHNICAL MANUAL OWNER S TECHNICAL MANUAL

Installation Manual. Q Series Quadplex Grinder Systems. Contents

Standard Service / Installation / Operation Manual Type W & P Water / Glycol Heat Transfer Coils

OIL SMART PLUG AND PLAY SYSTEM, Model #OSS-100

Installation Operation Maintenance ADDENDUM BULLETIN No. PS-IOM-HYP-0203-H

Installation Manual. D3600- Series Duplex Grinder Systems. Contents

PENBERTHY MODELS GL AND GH GAS OPERATED JET PUMPS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

QUALITY MISTING PUMPS

TITAN FLOW CONTROL, INC.

Open Frame Gas/Diesel Engine Driven Rotary Screw Compressor. Installation Guide

Wastewater Air Release Valve Models 48A, 49A

70.03 Victaulic Vortex TM

PRODUCT NUMBERING SYSTEM SERIES PHASE. 1: Single Phase 3: Three Phase

Manual. MicroTron. Series B. Installation Maintenance Repair. Manual. Chemical Metering Pump

DIFFERENTIAL PRESSURE RELIEF REGULATOR TYPE A4AL Port Size 3/4"- 4" (20-100mm) For Ammonia, R-22, R134a, R404a, R507 and other common refrigerants.

Val-Matic 1-4 Combination Air Valve (Single Housing Type)

LG-60-3PT-WP-309-BL-TSC

advanced FLOW engineering Instruction Manual P/N: , & , &

OWNER S MANUAL. Model GALLON SPRAYER REVISION 11/11

Model G14SD Vapor Management System

Val-Matic 1-4 Combination Air Valve (Single Housing Type)

Mizer Single Pump and Starter Box

Cartridge Filter Housings Nowata A Series

Grundfos Variable Speed GRUNDFOS INSTRUCTIONS. Installation and Operation

NECO Pumping Systems

advanced FLOW engineering Instruction Manual P/N: E Make: RAM Model: 2500/3500 HD Year: Engine: L6-6.7L (td)

WORKHORSE. Assembly / Operation Instructions / Parts

Installation Instructions

Low Profile Wrenches Operation and Maintenance Manual

ARAG Modular Electric Valve Operating Instructions and Parts Manual

Model 8309WC Barrier Free Shower & Eye/Face Wash

245 W. Roosevelt Road Building 12, Suite 83 West Chicago, IL

Water treatment services product catalog

AIR COMPRESSOR OPERATING INSTRUCTION AND PARTS LIST

Installation, Operation and Maintenance Manual

OWNER S MANUAL. Model: LG-30-TRL ( ) (30 Gallon Lawn & Garden Trailer Sprayer)

S003 LIQUID LEVEL FLOAT SWITCH. Single or Multi-Point, Vertically-Mounted, Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

M-3025CB-AV Fuel Pump

Operators Manual. Recirculating Chiller /06/08

9 VOLT ALKALINE. not included

Model 8309WC Barrier Free Shower & Eye/Face Wash

Operators Manual. Model 3370 Air Cooled Recirculator rev.8/98

RUFNEX Series Low Profile Wrenches Operation and Maintenance Manual

(SDU 50, SDU 90, and BKSDU) Shortening Disposal Unit * * Installation, Operation, Service, and Parts Manual

Open Frame Reciprocating Gas/Diesel Engine Driven Compressor. Installation Guide

IBT Series Square Drive Torque Wrenches


ActuLink ABS Module - ABS-MOD-400

Model 6518FR. NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

Mudhen Portable Slurry System Owners Manual

ProFlo FatBoy

SUPPLEMENTAL MANUAL FOR THE INSTALLATION, OPERATION AND MAINTENANCE OF THE XL234 FILTER VESSEL

DFA Series. Rainwater/Graywater Filtration Systems. Installation, Operation and Maintenance Manual DFM-2F-180 DFM-3F-180 DFM-3F-350

INSTALLATION/OPERATION/MAINTENANCE INSTRUCTIONS FOR ARCHON MODELS WD2010L, WD2010, WD2010H WASHDOWN STATIONS. ARCHON Industries, Inc.

INSTRUCTIONS FOR HYDRAULIC FILTER UNITS NEF PPE SOUTH

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL WELKER SAMPLE / INJECTION PUMP

Val-Matic QuadroSphere Trunnion Mounted Ball Valve

READ AND SAVE THESE INSTRUCTIONS

Val-Matic 4-20 Air/Vacuum Valve

Outdoor Bottle Fillers

AMERICAN AVK COMPANY TABLE OF CONTENTS

ILCS EDGE Jr EDP Installation Manual

Transcription:

Centrifugal Separator Operations & Maintenance Manual Record Your Model, Serial Number and Other Information on the back of this document. Manufacturing: Bypass & Filter Feeders, Glycol Feed Packages, Separators & Separator Systems, Tanks, Tank Stands, Chemical Batch Mixers, Corrosion Coupon Racks, Packaged Feed Systems and Custom Systems P.O. Box 8697, Brea, CA 92822-5697 Phone: 714) 257-9165 113 Viking Ave., Brea, CA 92821 Fax: 714) 257-9215 www.gtpcompany.com customerservice@gtpcompany.com O&M Manual INSTSEP Rev. 0115, Page 1 of 5

Contents Page 1.0 Introduction 2 2.0 Warranty 2 3.0 Unpacking 2 3.1 Order Verification 3 4.0 Location and Environment 3 5.0 Installation 3 5.1 Connecting to system 4 6.0 Pressure and Temperature Limitations 4 7.0 Routine Maintenance 4 7.1 Maintaining Recovery Tank 5 7.1 Setting Optional Purge Timer 5 8.0 Parts Listing 5 9.0 Wiring 5 10.0 Trouble Shooting 5 11.0 Notes 5 12.0 Product Label, Model Number, Serial Number and Pressure Settings 5 *** WARNING BEFORE YOU GET STARTED *** 1) All fasteners & fittings should be inspected and secured before operation as they may be loosened in transit 2) Personnel safety practices should apply at all times 3) Safety glasses or face shields and gloves should be worn 4) Do not service glycol feed package with out disconnecting power 5) Close isolation valve and release pressure before servicing any components on the system 6) All liquids in system should be drained before servicing 1.0 INTRODUCTION Thank you for choosing General Treatment Products Centrifugal Separators. These industrial centrifugal separators are design to remove heavier than water solids system flow. Utilizing centrifugal force, tangential entry and GTP proprietary features, such as vortex tube stabilizers and solids velocity hood, solids are removed through a series of chambers and eventually collected in an extended purge chamber at bottom of separator. Infrequent purging of the chamber is all that is required for effective solids maintenance. For further information, please contact us at customerservice@gtpcompany.com or call us at the phone number on the cover. 2.0 WARRANTY General Treatment Products Centrifugal Separators are guaranteed for five years from date of shipment against manufacturing defects in material and workmanship that develop in the service for which they are designed. We will repair or replace a defective part of this system when returned to our factory with freight prepaid; providing that the part is found to be defective upon inspection. We assume no liability for labor and/or other expenses in making repairs or adjustments. 3.0 UNPACKING Upon receipt of order, inspect package thoroughly. In the event there was damage incurred in transit you must notify the freight company within 3-5 days of receipt of order. Once inspected for damage and received in good condition, store indoors until installing. O&M Manual INSTSEP Rev. 0115, Page 2 of 5

3.1 ORDER VERIFICATION Model Numbering STX -0038 /CO2-RD04 Options CO * Clean out port added to purge chamber RD * Removable dome for accessing separator body RPC * Removable purge chamber for accessing purge LP22 Low profile mounting, 22.5 o LP45 Low profile mounting, 45 o ASME Separator welded to ASME code S316 Separator constructed of 316 stainless steel Line Size 0038 3/8 line connections 0050 1/2" line connections 0075 3/4" line connections 0100 1 line connections 0125 1 1/4" line connections 0150 1 1/2" line connections 0200 2 line connections 0250 2 1/2" line connections 0300 3 line connections 0400 4 line connections 0500 5 line connections 0600 6 line connections 0800 8 line connections 1000 10 line connections 1200 12 line connections 1400 14 line connections 1600 16 line connections 1800 18 line connections 2000 20 line connections Base Model STX Threaded MNPT line connections SVX Grooved End Victaulic line connections SFX Flanged 150# line connections Note: Not all options and sizes available on all separators. See pricing for details. 4.0 LOCATION AND ENVIROMENT Although there are no power requirements, centrifugal separators should not be exposed to direct elements. Separators when coupled with purging systems can require power. These installations require dry locations to validate warranty. In the case there is no dry location that is convenient to install the centrifugal separators. A shelter, awning or shed should to be installed to extend product life. 5.0 INSTALLATION Once location is decided on, separator needs to be securely mounted to concrete base. Be sure that mounting pad and anchoring bolts comply with local building codes. Automated purge packages come standard with an 8FT power cord. Power supply with no less than 10 amps should be within 8FT of package. Extension cords should not be used at anytime. Systems can be hardwired, if need. Have only an experienced electrician hardwire system. Wiring diagrams are provided in section 9.0. O&M Manual INSTSEP Rev. 0115, Page 3 of 5

5.1 CONNECTING TO THE SYSTEM Separators can be installed in a number of applications, these applications can determine how the separator is connected to the system. See diagrams below, if your installation / application is not listed below, contact factory before proceeding. Side Stream Applications: The side stream application shown in the diagram, the separator is installed in the discharge line of the recirculation pump. Separator sizing is typically 10% of system flow. Isolation valves will help control amount of flow through separator. This will vary depending on the pump head, design pressure and piping runs. Liquid filled pressure indicators will show pressure drop across the separator with should not exceed 12PSI. By throttling the inlet isolation valve you can adjust the amount of flow. Using a simple calculation, you can determine the exact amount of flow through the separator. By opening the purge valve, solids can be collected or discarded. Full Stream Installations:The full stream application shown in the diagram, the separator is installed in the discharge line of the recirculation pump. Separator sizing will at full systems flow. Unlike the side stream above, all of the system water is being seen by the separator. This is best when the system is frequently dirty, near an open field or has very critical needs on the solids removal. Separator pressure drop needs to be considered when installing. Making sure there is enough pressure left to keep the system operating properly. A recovery tank being used, will trap all the heavier and water solids from the systems and allow the system to recapture all the vital system fluid. No wasting water or chemicals. 6.0 PRESSURE AND TEMPERATURE LIMITATIONS: Separators maximum operating perimeters are 200PSI @ 200F. Some optional fittings, as noted in descriptions, may change limitations, contact factory for assistance. MATERIAL SHORT TERM TEMPERATURE OPERATING TEMPERATURE OPERATING PRESSURE Polyethylene (PE) 160 o F/69 o C 85 o F/36 o C N/A Polyvinylchloride (PVC) 140 o F/60 o C 85 o F/36 o C 100PSI/6.9BAR Chlorinated Polyvinylchloride (CPVC) 180 o F/77 o C 120 o F/49 o C 100PSI/6.9BAR Polypropylene (PP) 180 o F/77 o C 100 o F/49 o C 100PSI/6.9BAR Carbon Steel (CS) 200 o F/93 o C 200 o F/93 o C 150PSI/10.3BAR Cast Iron (CI) 200 o F/93 o C 200 o F/93 o C 150PSI/10.3BAR Brass (BR) 200 o F/93 o C 200 o F/93 o C 150PSI/10.3BAR Stainless Steel (SS) 200 o F/93 o C 200 o F/93 o C 150PSI/10.3BAR Note: Minimum Fluid Temperature is 50 o F/10 o C. 7.0 ROUTINE MAINTENANCE Routine maintenance for a centrifugal separator is quit simple. Once installed and started up, all the is need is scheduled inspection for leaks. 7.1 RECOVERY TANK Recovery tanks provided continual purging and reclaim the water that would otherwise be discarded with conventional mechanical purge systems. At start up, the system can be dirty from construction O&M Manual INSTSEP Rev. 0115, Page 4 of 5

and needs constant attention, but once the system is cleansed, recovery tank clean up should weekly or even monthly depending on environment and system cleanliness. (Dirty systems will need more frequent purges then systems that are clean, determine frequency by monitoring results) 7.2 SETTING OPTIONAL PURGE TIMER Optional purge cycle timer, automatically opens a motorized valve (based on time) and removes the collected solids from the purge chamber of the separator. During the purge the solids and system water is sent to drain. Set the time indicated by the days and hours on dial. Trip the switches for the days and hours you wish the timer to open the valve. (Dirty systems will need more frequent purges then systems that are clean, determine frequency by monitoring results) Inside the control panel, your duration has been preset for 10 minutes. Open the front cover and change as needed. 8.0 PARTS LISTING Separators do not carry many replacement parts, with the exception of accessories items like pressure gauges and recovery tank filters. Contact factory for help. 9.0 WIRING The only wiring needed is for the purge systems. Very simple diagrams are provided with each purge system. For help, please contact the factory or visit our website www.gtpcompany.com. 10.0 TROUBLE SHOOTING PROBLEM POSSIBLE CAUSE / ACTION Improper installation Low/Excessive Pressure Drop Improperly sized Installed backwards Installed backwards No solids removal Improperly sized Not enough flow rate If you are still having trouble, contact us at repairs@gtpcompany.com, or you can call us at the number on the front of the Instruction manual. 11.0 NOTES 12.0 PRODUCT LABEL Model: Serial Number: O&M Manual INSTSEP Rev. 0115, Page 5 of 5