Short Circuit. Sizes 0, 1, 2, and 690 Volt ratings - 32A through 630A All ratings include striker. 0% Lead

Low-Peak 600V Class RK1

General Purpose US Fuses

Gears & Fuse Gears. Medium Voltage Fuses Clips. Clip lock design for CL-14 series. Mounting Details for Clip Lock Cat. No.

TELECOMMUNICATIONS SPECIAL PURPOSE FUSES

PSC SQUARE BODY 690/700 Volt SEMICONDUCTOR PROTECTION FUSES

3.5. Current Limiting Fuses. Contents. CLPT and NCLPT Type Fuses. CLPT and NCLPT Type Fuses

Mica Element Support. Compacted Quartz Sand. Length B

LPSRK100SP 100A 600V TD Dual Elem Class RK1 Low Peak Fuse

LPSRK30SP 30A 600V TD Dual Elem Class RK1 Low Peak Fuse

Medium Voltage Fuses

Special Purpose Fuses

IEC Standard Back-Up Fuse-Links

3.6. Current Limiting Fuses. Contents. ACLS, BCLS, CLS, HCLS and NCLS Type Fuses. ACLS, BCLS, CLS, HCLS and NCLS Type Fuses

BUSSMANN. 8.3kV E-Rated SERIES. Medium voltage fuses for feeder circuit, switchgear and transformer. protection. Technical Data 10352

Secondaries. arc flash note Introduction. By Mike Lang, engineer and. Services Supervisor

6,3* 1,6 No Printed circuitboard Brass, Nickel plated MR 5-6 Y Yes Yes 5x20 &6x32

DIN HV Distribution. DIN HV fuses are partial-range high voltage currentlimiting fuses for use in distribution circuits from kV.

British BS 88 Fuses. High Speed Fuses. Introduction. General Information

D Type (DIAZED) FUSE-LINKS & SCREW CAP HOLDERS. EURO/IEC Fuses & Accessories 500 VOLT D TYPE DIAZED FUSE-LINKS, SCREW CAPS AND FUSE BASES

FX Full-Range Current-Limiting Fuse

Accessories. For product data sheets, visit

Fusetron FRN-R Class RK5 250Vac/125Vdc A, dual element, time-delay fuses

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.

Protistor size 14x51 ar 690VAC (IEC) / 700VAC (UL)

North American Power Fuses

NH Solid Blades 690 VAC sizes 000 to 3

PT Medium voltage fuses for potential and small power transformers

LENRK/LESRK CLASS RK1 DUAL ELEMENT TIME-DELAY FUSES

N0N A 250V One-Time Class H Fuse

LPCC3 3A 600V TD Class CC Low Peak Fuse. Features amperage rating. Dimensions and Weight. Long Description. Manufacturer Information

NH fuse-links gg 690VAC top indicator/live gripping-lugs size 4 and 4a

X-Limiter full-range current-limiting fuse

Section Contents. Page. Introduction... 72

Low-Peak LPJ Class J 600Vac/300Vdc, 1-60A, dual element, time-delay fuses

Medium Voltage. Section Contents. Page. Introduction...100

Subject: Trans-Guard EX Full-Range Current-Limiting Capacitor Fuses Date: 4/10/09 File: PCUP _EX

K-Limiter high ampere Companion II fuse

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

Limitor -G General Purpose Fuses

Medium Voltage Metal-Enclosed Switches

FRNR A 250V TD Class RK5 Dual Elem Fuse-Fusetron

Product Selection Guide

Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A

Amp-Trap 2000 Fuses FOR TYPE 2, NO DAMAGE CIRCUIT PROTECTION IN ALL THE CONFIGURATIONS YOU NEED. Class J / AJT...A2. AJT Reducer Fuses...

Low voltage, branch circuit fuses

Descriptive bulletin. Medium voltage load interrupter switchgear Reliable, low maintenance and economical for distribution applications

NH fuse-links am VAC with striker, size 0, 1, 2, 3, 4

NH fuse-links am 690VAC top indicator/live tags size 4, 4a

A. Submit manufacturer's literature and technical data before starting work.

NH fuse-links gg 500VAC top indicator/live gripping-lugs size 4, 4a

Applications. Distribution transformers up to 2000 kva High-voltage motors up to 3 MW Capacitors up to1200 kvar MV voltage transformers Cable feeders

BUSSMANN. LIMITRON FNQ-R Class CC 600Vac, A, time-delay fuses SERIES. Technical Data Carton quantity: Catalog symbol: Dimensions - in:

LOW-PEAK Time-Delay Fuses KRP-C Class L 600 Volt A

PROTECTION AND CONTROL

Semiconductor Fuses European Fuses

onlinecomponents.com

High Speed Fuses. Section Contents Page

Low Voltage, Branch Circuit Rated Fuses

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Selection Guide. HHD-BPT, DIN Style, Current-Limiting, Back-Up, Potential Transformer Protection

For Type 2, No Damage circuit protection in all the configurations you need. A Amp-Trap 2000 Fuses

SWITCHGEAR DIVISION PRODUCT PROFILES

High voltage current limiting Fuse links type CEF

T CLASS T FUSE BLOCKS

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS

R-Rated medium voltage fuses for motor circuit protection

R-Rated medium voltage fuses for motor circuit protection

Guide Specification. Three-Phase Solid Dielectric Trident-SR with SafeVu Integral Visible Break

Product Catalog Medium Voltage Fuses. Circuit Protection

Fuses for Semiconductor Protection - European Standard. Class: Voltage ratings: Current ratings: Standards: Approvals: Features and Benefits

NX indoor current-limiting fuses

Protistor size 70 gr 690VAC (IEC)

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

Industrial Control Transformers

Medium Voltage Metal-Enclosed Switches

Fuse/Var Technical Data

Medium voltage fuses - European Fuses

Each of these factors, as they apply to the selection of Types CLE and CLS current limiting fuses, is briefly outlined on the following pages.

R-MAG. Vacuum Circuit Breaker with Magnetic Actuator Mechanism

Semiconductor (AC) fuses

NH fuse-links gg 400VAC double indicator/live gripping-lugs size 000, 00, 1, 2, 3

Bussmann. Circuit Protection Solutions

QO and QOU Miniature Circuit Breakers QOU Miniature Circuit Breakers

SPECIFICATION BULLETIN

Ferrule fuses. High Speed Fuses

YOUR ELECTRICAL SYSTEM IS YOUR LIFELINE AMP-TRAP 2000 FUSES

Critical Power Switchboards. Selection and Application Guide

Protistor size 31 ar 690VAC (IEC) / 700VAC (UL)

3.2. Current Limiting Fuses. Contents

R-MAG Vacuum Circuit Breaker with Magnetic Actuator Mechanism 15.5 kv - 27 kv; 1200 A A

www. ElectricalPartManuals. com

Transcription:

SRIS -RATD / MDIUM VOLTAG FUSS 5kV AND 15kV CLIP-LOCK MOUNTD FUSS Amp-trap -rated 5kV and 15kV fuses have 3" diameter barrels and mount in unique cam-locking clips, for superior connections as well as easy installation and replacement. They are UL listed as general purpose current-limiting fuses and are for use indoors (or outdoors in a weatherproof enclosure). The unique time-current characteristic of Ferraz Shawmut -rated fuses allows them to be closely sized to transformer full load rated current, as recommended by I guidelines, without being affected by normal magnetizing inrush current. CL- 14 fuses are typically sized at transformer rated current of 133%, thereby providing superior overall protection. HIGHLIGHTS: -Rated UL Listed 5.5kV Complies with ANSI C37.46 APPLICATIONS: Protection for 5.5kV or 15.5kV transformers or distribution systems Features/ Benefits UL Listed for compatibility with UL listed equipment Clip-Lock mounting for reliable high integrity connection into circuit Current limiting for superior equipment protection Blown-fuse indicator gives positive identification of open fuse Non-venting for silent operation Metal mbossed Catalog Number and manufacturing date for lasting identification Ratings Approvals DFINITIONS: -rating -rated fuses operate as follows: 100 or less - must melt in 300 seconds (5 mins.) at 200 to 240% of (ampere) rating. Over 100 - must melt in 600 seconds (10 mins.) at 220 to 264% of (ampere) rating. xample - A 100 fuse must melt in 300 seconds with an applied current of 200 to 240 amperes. General Purpose Current-Limiting Fuse A general purpose current-limiting power fuse is one that is capable of interrupting all currents from its rated interrupting rating down to the current that causes melting of the fusible element in one hour. A055C AC: 10 to 600 5.5kV, 63kA I.R. Sym. A155C AC: 10 TO 300 15.5kV, 50kA I.R. Sym Clip-Lock Clips for Fuses: 228-700-520 (One pair of clips) UL Listed to JG, Fuses Over 600 Volts 15

-RATD / MDIUM VOLTAG FUSS / A055C 5.5kV Clip-Lock Mounted Catalog Numbering System A 0 5 5 C 2 D 0 R 0-4 5 0 Ampere Rating Revision/No. Special Features Diameter (D=3 ) No. of Barrels Style (C= Clip Lock Mount) Max. Voltage Rating (055=5.5kV) Amp-trap Fuse Indicator Flush with Surface in Untripped Position Blown Fuse Indicator Figure A Figure B Figure C Catalog Numbers, Ratings, Dimensions, Series, 5.5kV DIMNSIONS Inches (mm) INTRRUPTING NW CATALOG OLD CATALOG AMPR NUMBR OF FIG. RATING NUMBR NUMBR RATING BARRLS A B C RMS SYM.* AMPRS 5.5kV Max. Clip-Lock Style 15.25 (387mm) Clip Centers 3 (76.2mm) Barrel Diameter A055C1DORO-10 225-007-937 10 15 938 15 20 939 20 25 940 25 30 941 30 1 A 16.81 16.12 0.5 63,000 40 942 40 (427) (410) (13) 50 943 50 Tripped 65 944 65 Force 80 945 80 2 lbs. 100 946 100 125 947 125 150 948 150 5.5kV Max. Clip Lock Style 21.25 (540mm) Clip Centers 3 (76.2mm) Barrel Diameter A055C1DORO-200 225-007-949 200 250 950 250 300 951 300 1 A 22.81 22.12 0.5 63,000 400 952 400 (580) (562) (13) Tripped A055C2DORO-450 953 450 Force 500 954 500 2 B 2 lbs. 600 955 600 * RMS ASYM. AMPRS = RMS SYM. AMPRS x 1.6 16

-RATD / MDIUM VOLTAG FUSS / A055C A055C1DORO 10 to 400 and A055C2DORO 450 to 600 Total Clearing Time Current Data, 5.5kV Fuses Minimum Melting Time Current Data, 5.5kV Fuses A055C1DORO 10 to 400 and A055C2DORO 450 to 600 17

-RATD / MDIUM VOLTAG FUSS / A055C A055C1DORO 10 to 400 and A055C2DORO 450 to 600 Peak Let-Thru Current Data, 5.5kV Fuses Maximum Instantaneous Peak Let-Thru Amperes Available Current in RMS Symmetrical Amperes 18

-RATD / MDIUM VOLTAG FUSS / A155C 15.5kV Clip-Lock Mounted Catalog Numbering System A 1 5 5 C 1 D 0 R 0-8 0 Ampere Rating Revision/No. Special Features Diameter (D=3 ) No. of Barrels Style (C= Clip Lock Mount) Max. Voltage Rating (155=15.5kV) Amp-trap Fuse Indicator Flush with Surface in Untripped Position Blown Fuse Indicator Figure A Figure B Figure C Catalog Numbers, Ratings, Dimensions, Series, 15.5kV DIMNSIONS Inches (mm) INTRRUPTING NW CATALOG OLD CATALOG AMPR NUMBR OF FIG. RATING NUMBR NUMBR RATING BARRLS A B C RMS SYM.* AMPRS 15.5kV Max. Clip-Lock Style 18.25 (464mm) Clip Centers 3 (76.2mm) Barrel Diameter A155C1DORO-10 225-007-967 10 15 968 15 19.81 19.12 0.5 20 969 20 (504) (486) (13) 25 970 25 1 A Tripped 50,000 30 971 30 Force 40 972 40 2 lbs. 50 973 50 15.5kV Max. Clip-Lock Style 21.25 (540mm) Clip Centers 3 (76.2mm) Barrel Diameter A155C1DORO-65 225-007-974 65 80 975 80 1 A 22.81 22.12 0.5 100 976 100 (580) (562) (13) A155C2DORO-125 977 125 2 B Tripped 50,000 Force A155C3DORO-150 978 150 2 lbs 200 979 200. 250 980 250 3 C 300 981 300 * RMS ASYM. AMPRS = RMS SYM. AMPRS x 1.6 19

-RATD / MDIUM VOLTAG FUSS / A155C A155C1DORO 10 to 100 / A155C2DORO 125 / A155C3DORO 150 to 300 Minimum Melting Time Current Data, 15.5kV Fuses Total Clearing Time Current Data, 15.5kV Fuses A155C1DORO 10 to 100 / A155C2DORO 125 / A155C3DORO 150 to 300 20

-RATD / MDIUM VOLTAG FUSS / A155C A155C1DORO 10 to 100 A155C2DORO 125 A155C3DORO 150 to 300 Peak Let-Thru Current Data, 15.5kV Fuses Maximum Instantaneous Peak Let-Thru Amperes Available Current in RMS Symmetrical Amperes 21