REQUEST FOR QUOTATION

Similar documents
Supply of Batteries

Ref:CL/Mech./ Cal /BID-01(13-14) Date: 10 July 2013

TECHNICAL SPECIFICATIONS

TECHNICAL BID T 3627

Tender documents for supply, erection & commissioning of Plante Type Battery to 2x210 MW IB Thermal Power Station.

Section VI: List of Requirements (REVISED)

THE ORIENTAL INSURANCE CO.LTD. REGIONAL OFFICE: IDA Building 4 th Floor, 7,Race Course Road, Indore (M.P.) REQUIREMENT

Open Tender Enquiry OUTSOURCING OF PHOTOCOPY WORK AT SCOOTERS INDIA LIMITED SINGLE BID SYSTEM. SCOOTERS INDIA LIMITED Page 1

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

INVITATION FOR QUOTATION. TEQIP-II/2015/GJ1G02/Shopping/M-EE-09

INDIAN MARITIME UNIVERSITY KOLKATA CAMPUS

/ Telefax : No: 1(2)2015-E/ Battery& Charger TVH/ Dated:

CERTIFICATE OF ACCREDITATION

SPECIFICATIONS FOR MOTOR OPERATED VALVES

Certificate of Accreditation

TECHNICAL SPECIFICATION FOR 11 KV AUTOMATIC CAPACITOR SWITCH

TECHNICAL BID T 3610

Calitron Calibration Laboratory, U1: 207, Kohinoor Arcade, Tilak Chowk, Nigdi, Pune, Maharashtra

Dakshin Gujarat Vij Company Limited

Solar Energy Corporation of India Limited New Delhi Expression of Interest for Setting up of Solar PV Manufacturing Capacities in India

Alcalab Private Limited, 3rd Floor, Ashiana Trade Centre, Adityapur, Jamshedpur, Jharkhand. Discipline Mechanical Calibration Issue Date

TENDER FOR DG SET. Tender for DG SET. POCKET-14, SECTOR-8, PHASE-1, DWARKA, NEW DELHI Website: TENDER DOCUMENTS FOR

INDIAN INSTITUTE OF TECHNOLOGY, KANPUR DEPARTMENT OF ELECTRICAL ENGINEERING

NATIONAL CENTER FOR COMBUSTION RESEARCH AND DEVELOPMENT (NCCRD) INDIAN INSTITUTE OF TECHNOLOGY MADRAS CHENNAI , INDIA

Supply, Installation and Commissioning of 1 No 50 Watt LED. based SPV SLS at Nadia District Library, Krishna Nagar, Nadia.

GUJARAT ENERGY TRANSMISSION CORPORATION LTD. TECHNICAL SPECIFICATIONS. 110 V, 100 Ah / 250 Ah & 220 V, 250 Ah / 350Ah TUBULAR LEAD ACID BATTERY SETS

Page : 1 of 16. FIELD OF TESTING : Calibration and Measurement CALIBRATION & MEASUREMENT CAPABILITY EXPRESSED AS AN UNCERTAINITY *

BIDDERS SHOULD SUBMIT THE DOWNLOADED DOCUMENTS, DULY FILLED, STAMPED AND SIGNED, AS PER THE INSTRUCTIONS GIVEN HEREUNDER.

REQUEST FOR PRICE QUOTATION FOR Laser Toner Cartridges. DATE BIDS REQUESTED: June 24, 2009 WEDNESDAY 10:30 A.M BID # RETURN TO:

: Material Description Quantity UOM


Tender No:- MTL/PUR/213/Elect/ (K)/9. 2 NEW Moulded case Circuit Breaker with O/L & S/C No 02

INVITATION FOR QUOTATION. TEQIP-III/2018/uceo/Shopping/48

INVITATION FOR QUOTATION. TEQIP-III/2017/uiet/Shopping/35

ARAI/TA(4G_RV)/HORIBA/MEXA 584L/ Dated 25 Mar 2014

ARAI/TA(4G_RV)/SMS/D680/ Dated 21 st Mar 2015 CERTIFICATE FOR COMPLIANCE TO THE CENTRAL MOTOR VEHICLES RULES

SPECIFICATION FOR REWIRABLE FUSES (KITKAT FUSES) 100A & 200A SPECIFICATION NO.: DIST/ A- KIT /

Guaranteed Technical Particulars(GTP) Deviation/Remarks Specify if any. Computerized Motor testing system suitable to test LV 3 phase motors

ANNEXURE XI. (Ni Cd Battery Bank) TECHNICAL SPECIFICATIONS OF 125V STATION BATTERY BANK OF GTG I.

SPECIFICATIONS FOR 50 V, 600 AH LEAD ACID BATTERY

QA Tech (A Division of GMP Technical Solutions Pvt. Ltd.), L-73, Verna Industrial Estate, Verna Salcette, Goa

ARAI/TA (4G)/AIRVISOR/AVG500/ Dated 17 th Apr 2017

4.1 Type of the valve and materials of construction of body and trim shall be as specified in valve Data sheet.

MAHARASHTRA NATURAL GAS LIMITED

CENTRAL UNIVERSITY OF JHARKHAND, RANCHI

AIRPORTS AUTHORITY OF INDIA OFFICE OF THE AIRPORT DIRECTOR ल. ग. ब. हव ई L G B I AIRPORT, GUWAHATI TECHNICAL DIRECTORATE क ट शन

SAVE ENERGY FOR BENEFIT OF SELF AND NATION

Technical Specifications

Hi-Tech Calibration, 307, 3rd Floor, Govinda Complex, Char Rasta, Vapi, Gujarat. Discipline Mechanical Calibration Issue Date

TECHNICAL BID T

TENDER DOCUMENT BHARAT HEAVY ELECTRICALS LIMITED, HEEP, RANIPUR, HARIDWAR

Regional Office: Vijayapura Plot No6, Trimurthy Nagar Managuli Bypass Road, Vijayapura Diesel Generator Required on Rental Basis

INVITATION FOR QUOTATION. TEQIP-III/2018/gcej/Shopping/50

NLC INDIA LIMITED (formerly Neyveli Lignite Corporation Limited) ('NAVARATNA'-Government of India Enterprise) MATERIALS MANAGEMENT COMPLEX

ARAI/TA(4G)/SMS/D680/ Dated 28 Jan 2010

Accurate Measurements, Plot No.103, D Block, Meethapur Ext., Badarpur, New Delhi. Discipline Mechanical Calibration Issue Date

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2017 & ANSI/NCSL Z

(LAST DATE OF SUBMISSION: ) QUOTATION FOR ANNUAL MAINTENANCE CONTRACT OF SERVERS, COMPUTERS, PRINTERS, NETWORKING AND LAN

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

Supply of 63 kva DIESEL GENERATOR SET WITH AMF

NLC INDIA LIMITED (formerly Neyveli Lignite Corporation Limited) ('NAVARATNA'-Government of India Enterprise) MATERIALS MANAGEMENT COMPLEX

NIT No.:-10/WEX/MCR/HYD. PRESS/2-303/ /Dt

CERTIFICATE OF ACCREDITATION

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 & ANSI/NCSL Z

RAJIV GANDHI UNIVERSITY OF KNOWLEDGE TECHNOLOGIES BASAR Nirmal District, Telangana Ref: RGUKT-B/Proc/Elec,Maint/Q08/2018, dated

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT

Department of Community Medicine

UNIVERSITY OF CALCUTTA Centre for Research in Nanoscience and Nanotechnology JD-2, Sector-III, Salt Lake City Kolkata

ARAI/TA(4G)/GEN-MAINT/EXOSCAN-V/ Dated 26 th Mar 2009 CERTIFICATE FOR COMPLIANCE TO THE CENTRAL MOTOR VEHICLES RULES

TECHNICAL BID. T 4329 (E-Tender I.D. No. ) Subject: Supply of Various Measuring Instruments for TMD-6 of 500 MW Unit No.6 of GSECL Ukai TPS.

SKID MOUNTED PORTABLE DIESEL ENGINE DRIVEN CENTRIFUGAL SUMP PUMP SET INSTALLATION& COMMISSIONING 10 INSTALLATION& COMMISSIONING 1 AU

Institute for Design of Electrical Measuring Instruments, Swatantryaveer Tatya Tope Marg, Chunabhatti, Sion, Mumbai, Maharashtra

OIL INDIA LIMITED Fax (A Govt. of India Enterprise) Udyan Vihar, Narengi, Guwahati, Assam

SPECIFICATION FOR HARDWARE FITTINGS SUITABLE FOR TENSION STRING TO BE USED FOR 11KV/22KV LINE

To Date: 23/03/2017. Respective Bidders,

IMPORTANT NOTE (C) SENIOR ADVISER(CONTRACT & PURCHASE), OIL INDIA LIMITED, PLOT NO. 19 SECTOR 16A NOIDA

Autocal Solutions Pvt. Ltd., Plot No. BG-74, Gala No. 1 & 2, Jai Tulja Bhavani Indl. Premises, Telco Road, MIDC Bhosari, Pune, Maharashtra

NLC INDIA LIMITED (formerly Neyveli Lignite Corporation Limited) ('NAVARATNA'-Government of India Enterprise) MATERIALS MANAGEMENT COMPLEX

Inviting Tenders for Supply, Installation, Testing and Commissioning of 500 KVA DG Set for Temperature Controlled Warehouse at Medchal, Hyderabad.

: Material Description Quantity UOM

CITY AND COUNTY OF SAN FRANCISCO. SPECIFICATION FOR Copier Lease Agreement Last revision 03/03/2016

Delivery Schedule. Specification. Delivery Schedule. Specification

Q-Tech Engineering Services, S-134, C/o, Precision Engineering Works, MIDC, Bhosari, Pune, Maharashtra

Palabora Copper REQUEST FOR PROPOSAL SUPPLY AND DELIVERY OF BEARINGS AND ACCESSORIES RFP.PC.2017/18 PART 1 PROPOSAL INFORMATION AND CONDITIONS

REQUEST FOR PROPOSAL


A Guide to Dry Block Calibration

Technical Specification for Electric Motor Driven, Skid Mounted Chemical Dosing Pump:

Shriram Institute For Industrial Research, 14-15, Sadarmangala Industrial Area, Whitefield Road, Bangalore, Karnataka

BANGALORE ELECTRICITY SUPPLY COMPANY LIMITED

TECHNICAL SPECIFICATION FOR 11 KV CAPACITOR BANK

BHARAT HEAVY ELECTRICALS LIMITED Industrial Valves Plant Goindwal (AMRITSAR) Enquiry Date:

PROMPT ENGINEERING P.O. BOX BARWA VILLAGE, WAKRA, BUILDING NO. 6 SHOP NO. 19 AND 20 DOHA QATAR

File No. EL/EE/NAD/Tech/1-13/2018/822 Dated: 29/08/2018 OFFICE OF THE EXECUTIVE ENGINEER NORTH ANDAMAN DIVISION ELECTRICITY DEPARTMENT DIGLIPUR

Request for Quotation

REQUEST FOR QUOTATION (RFQ) FOR PROCUREMENT OF FORKLIFT FOR CENTERAL WAREHOUSE -UNDP GLOBAL FUND

SAKHALIN ENERGY INVESTMENT COMPANY LTD. INVITATION TO TENDER

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT

Ref No : ETPL/GGSIPU/SNUTS/ Date : Nov 15, 2017

Transcription:

REQUEST FOR QUOTATION TO, GAIL WEBSITE VENDOR India Vendor Code - 101019938 RFQ No.: GAIL/08/RJ19140/3300025749/ Dated : 23.07.2008 Kind Attn : Mr/Ms Dear Sir/Madam, GAIL (India) Ltd. invites you to submit your offer in sealed envelope superscribing RFQ No. & Due date for the following services in complete accordance with enquiry documents/attachments: Name of work : Annexure-1 attached for Scope of work and Special condition of contract,annexure-2 Technical Details of Masters Bid Due Date & Time Opening of Bids on Validity of Offer Upto : 30.12.2008 Date of Pre Bid Conference : at Hrs : 13.08.2008 at 14:00 Hrs : 13.08.2008 at 15:00 Hrs (In case of Two Bid system tender,unpriced bids shall be opened.) Instruction to Bidders : OFFERS ARE REQUIRED TO SUBMIT IN 2 BID SYSTEM. TECHNICAL BID AND PRICE BID SEPARATELY AND BOTH SHOULD BE IN ONE ENVELOPE TO SR MANAGER(C&P), AV APPA RAO ROAD, GAIL INDIA LTD, RAJAHMUNDRY. ANDHRA PRADESH. 533103. IF YOU ARE NOT PARTISIPATING PL RETURN THE TENDER DOCUMENT WITH THE REASONS FOR OUR RECORDS Delivery/Completion Scheduele : ONE YEAR FROM THE DATE OF FOI Terms of Payment : 100% AFTER CALIBRATION OF INSTRUMENTS AND SUBMISSION OF INVOICE Price Reduction Schedule : LD WILL BE APPLICABLE 0.5% PER WEEK MAXIUM OF 5% ON TOTAL ORDER VALUE.

RFQ No.: GAIL/08/RJ19140/3300025749/ Dated : 23.07.2008 Other Contractual Stipulations: AS PER RFQ AND TENDER DOCUMENT. General Conditions of Contract : AS PER GCC AND TENDER DOCUMENT Special Conditions of Contract : AS PER ENCLOSED Bid Evaluation Criterion: AS PER ENCLOSED Bids complete in all respects should reach office of Incharge (C&P), GAIL (India) Ltd., at the above address on or before 14.00 hrs of the scheduled date. Bids received after the due date and time are liable to be rejected. GAIL reserves the right to accept or reject any or all tenders received at its absolute discretion without assigning any reason whatsoever. Thanking You, Yours truly, For & on behalf of GAIL (India) Ltd. (Authorised Signatory)

Tender No.: 08/RJ19140 SCHEDULE OF RATES Out. lev. Item No. Service Description Qty. UOM Rate Amount ITEM 00001 Calibration of Masters at NABL Lab Plant : 3130,NG Transmission - Rajamundhry 10 TEMPERATURE BATH 1 EA Model MP40R,Make-Nagman, -40~123degc 20 MULTIFUNCTION CALIBRATOR 20DPC 1 EA Model:Microcal20DPC Make:Eurotran, External High Pr.Sensor 0~160 Bar,External low Pr.Sensor: -1~2bar 30 MULTIFUNCTION CALIBRATOR CA100 1 EA Model:CA100-255701 Make:Yokogawa generation Function:18 ranges,measurement Function:8ranges 40 RTD TEMPERATURE CALIBRATOR 1 EA 100DEGC Model:18591 PDG Make:Apex : 0~100degc 50 RTD TEMPERATURE CALIBRATOR 1 EA 300DEGC Model:18591 PDG Make:Apex, :0~300degc 60 BORE GAUGE 35~60 MM 1 EA S.L No:573778 Make:Mitutyo,:35~60 MM, No of Pins:7, No of washers:4 70 BORE GAUGE 50~150 MM 1 EA S.L No:591580 Make:Mitutyo,:50~150 MM, No of Pins:10, No of washers:4 80 BORE GAUGE 160~250 MM 1 EA S.L No:620199 Make:Mitutyo,:160 ~ 250 MM, No of Pins:7, No of washers:7 90 BORE GAUGE 250~400 MM 1 EA S.L No:602136 Make:Mitutyo,:250~400 MM, No of Pins:5, No of washers:4 100 DIGIMATIC DIGITAL INDICATOR 1 EA S.L No:44408 Make:Mitutyo,: 0 ~ 12.7 mm, 110 VERNIER CALIPER 0~300 MM 1 EA Model:Digital Make:Mitutyo,: 0 ~ 300 mm,internal Dia,External Dia,Depth 120 VERNIER CALIPER 0~150 MM 1 EA Model:Digital Make:Mitutyo,: 0 ~ 150 mm,internal Dia,External Dia,Depth Quotation Item 00001 Total Value : TOTAL QUOTATION VALUE : Page 1

Bid Evaluation Criterion: i. Bidders calibration lab must be NABL accredited laboratory Bidder should submit copy of NABL accreditation certificate along with the scope of accreditation. Conditions of Contract: 1.0 SCOPE: The Calibration of Master measuring Instruments (DUC) as per the list is to be done against Master instruments with calibration Reference standards traceable to National, International Standards. The Test instrument validity period of calibration need to be mentioned in the certificate after the calibration is completed. The Accuracy of reference masters after considering uncertainty Compared to instrument under calibration should be better than at least 4:1 ratio. Necessary Calibration certificates shall be issued separately for each instrument, duly certified by the testing authority. The calibration certificate should invariably contain the following information i. Allowable deviation or error of each measurement value as per manufacturer specification. ii. Deviation found for each measured value of DUC w.r.t reference standard, iii. Expanded uncertainty for each parameter in the unit of measured value. iv. Coverage factor (K) and measurement confidence level. v. TUR (test uncertainty ratio) for each measured. vi. General details of DUC. vii. Details of reference master including Accuracy/validity of calibration/uncertainty/certificate number issued by primary master laboratory/s.l.no/make/model. viii. Environment conditions like temperature, relative humidity in which calibration is done. ix. General impression of laboratory for the usability of DUC for calibrations x. The agency should also issue the copy of the original calibration certificates of all Master Reference calibrators used for calibration as a reference purpose. xi. However calibration agency can submit separate additional sheet for TUR, uncertainty value and other calibration parameter if their standard format is not fully accommodating the required details. 2.0 PERIOD OF CONTRACT: Period of contract will be one year from the date of issue of work order. 3.0 PAYMENT: 100% payment shall be released after calibration of test Instruments by effecting statutory deductions. Payment shall be released through e-banking mode only. Please furnish your following details to facilitate e-payment. i) Bank Account No. ii) Bank Name

iii) iv) Branch Code Address of the Branch 4.0 TAXES: Service Tax at the prevailing rate shall be paid against the submission of proof of service tax registration no. of the agency. 5.0 SPECIAL CONDITIONS: i) The tentative calibration schedule of the instruments to be calibrated is indicated as given under. ii) The instrument will be dispatched to the lab before the due date of calibration on through courier or in person iii) iv) After calibration dispatch of the instrument is under the scope of vendor, if the instrument is dispatched through courier then packing and handling should be through a reputed agency with wooden crate packing. In case of any deviation in the instrument the same should be adjusted to bring it within the allowable limit. v) The instruments need to be calibrated in all aspects and to be handed back to GAIL along with calibration certificate within 1 week on receipt of the Instruments at agency's laboratory 6.0 OTHER CONDITIONS: 1. The Agency has strictly to be a certified testing laboratory. 2. The agency's testing laboratory shall hold a valid NABL accredited certificate for the instruments under test. 3. The testing should be done strictly as per the relevant National standards confirming to the vendors document for the particular instrument under test and the uncertainty calculations should be as per relevant ISO standards and the same should be mentioned in the calibration certificate provided after the calibration. However calibration agency can submit separate additional sheet for TUR, uncertainty value and other calibration parameter if their standard format is not fully accommodating the required details. 4. The agency should ensure that their master Reference Calibrators should have the calibration validity as on the date of calibration traceable to National and international primary Laboratory.

5. Agency shall provide a sticker indicating the status of calibration with validity to each instrument. 6. The instrument should be handled properly during the calibration. The agency will be responsible for any problem created out of negligent handling of calibrating instruments. The agency is required to report the same to GAIL immediately in such cases. 7. During the course of calibration if any damage or theft occurred to the instrument, appropriate recovery shall be made from the agency at the sole discretion M/s GAIL. 8. Transit insurance is in the scope of M/s GAIL. 9. Documentary proof should be submitted for the following: i. SCOPE OF ACCREDIATION BY NABL ii. TRACEABILITY OF CALIBRATION TO NATIONAL, INTERNATIONAL STANDARDS. iii. TRACEABILITY CERTIFICATES OF MASTERS USED FOR CALIBTRATION SHOULD BE SUBMITTED ALONG WITH CALIBRATION CERTIFICATES AFTER COMPLETION OF CALIBRATION. Enclosures: 1. Data Sheet for Accuracy s, 2. GCC, 3. Health Safety and Management Conditions, Agreed upon Terms & Conditions: As per tender terms and conditions.

Calibration schedule S.No INSTRU-MENT NAME S.NO. OF INSTRU-MENT Make 01 MULTIFUNCTION CALIBRATOR Generation Function:18 ranges Measurement function:8 ranges 02 TEMPERATURE BATH (-40 ~123) ºC 03 RTD TEMPERATURE CALIBRATOR 0~100 ºC 04 RTD TEMPERATURE CALIBRATOR 0~300 ºC 05 BORE GAUGE (35~60)mm, with 7 pin and 4 washer 06 BORE GAUGE (50~150)mm, with 10 pin and 4 washer 07 BORE GAUGE (160~250)mm, with 7 pin and 7 washer 08 BORE GAUGE (250~400)mm, with 5 pin and 4 washer 09 DIGIMATIC DIGITAL INDICATOR 0~12.7mm 10 VERNIER CALIPER 12 INCH for (3 ranges) 11 VERNIER CALIPER 06 INCH for (3 ranges) 12 Multifunction calibrator with pressure module, External Sensor High Pressure 0~160 bar Low Pressure -1~2 bar 2557AGA733H MP060211562 Yokogawa CA-100 NAGMAN MP-40R 0495801 (ALTOP) 00000 (ALTOP) 573778 Mitutoyo 591580 Mitutoyo 620199 Mitutoyo 602136 Mitutoyo 44408 Mitutoyo 069167 Mitutoyo 04034952 Mitutoyo S/N: 72334 Eurotran, 20 DPC

Multifunction calibrator : Make: Druck, Unomat Model: TRX-II Serial Number: T3286 a) Pressure Module: Sr no Item to be Calibration Max. Allowable deviation calibrated 1) Pressure -1 ~ 2 bar g ± 0.05% fs Module P1 2) Pressure Module P2 0 ~ 160 bar g ± 0.05% fs b) Generation Function (Source): Srno Item to be Calibration Max. Allowable deviation calibrated 1) DC mv -10~ 100 mv ± 0.01% DC V 0 ~ 12V ± 0.01% 2) DC ma 0 ~ 24mA ± 0.02% 3) Ω 0 ~ 400Ω ± 0.005% 400 2000Ω ± 0.005% 4) RTD ( PT 100,IEC) -200~ 850 ± 0.3 c) Measurement Function: Sr no Item to be Calibration Max. Allowable deviation calibrated 1) DC mv 0 600 mv ± 0.02% DC V 0 6V ± 0.025% DC V 6 60V ± 0.05% 2) DCmA 0 52mA ± 0.02% 3) Resistance Ω 0 400Ω ± 0.005% 400 2000Ω ± 0.005% 4) RTD ( PT 100,IEC) -200to 850 ±0.25 Multifunction calibrator: 1

Make: Yokogawa Model: CA-100-255701 Serial Number: 2557GA733H a) Generation Function: Sr.no Item to be calibrated Calibration Max. Allowable deviation 1) DC mv 0 100 mv ± 0.02% DC V 0 1V ± 0.02% DC V 0 10V ± 0.02% 2) DC A 0 20mA ± 0.025% 3) RTD ( PT 100,IEC) -200to 850 (-200 0 ) 0.3 (0 400 ) 0.5 (400-850) 0.8 4) Ω 0 500Ω ± 0.02% Ω 0 5kΩ ± 0.05% Ω 0 50kΩ ± 0.1% 5) Frequency 1-100 HZ 1 digit 100-1000 HZ 1 digit 1-10 KHZ 1 digit 10 50 KHZ 1 digit 6) Thermocouple Type K -210 1372 (-200 100 ) 0.6 (-100 400 ) 0.5 (400-1200) 0.7 (1200-1372) 0.9 Thermocouple Type F -250 1000 (-250 200 ) 1.2 (-200 100 )0.6 (-100-600)0.5 (600-1000)0.6 Thermocouple Type J -210 1200 (-210 100 ) 0.6 (-100 800 )0.5 (800-1200)0.7 (600-1000)0.6 Thermocouple Type T -250 400 (-250-200 ) 1.5 (-200 400 )0.5 Thermocouple Type N -200 1300 (-200 100 ) 1.0 (-100 900 )0.7 (900-1300) 0.8 Thermocouple Type R -40 1767 (-40 100) 1.5 (-100 1767)1.2 Thermocouple Type B -400 1820 (400 600) 2.0 (600 800)1.5 (800-1820)1.1 b)measurement Function: Sr no Item to be Calibration Max. Allowable deviation 2

calibrated 1) DC mv -500 500 mv ± 0.02% DC V -5 5V ± 0.02% DC V -35 35V ± 0.02% 2) DCmA -20 20mA ± 0.025% DCmA 0 100mA ± 0.04% 3) RTD ( PT 100,IEC) -200to 850 0.3 Resistance Ω 0 500Ω ± 0.05% Resistance Ω 0 5kΩ ± 0.05% DIGITAL VERNIER CALIPER Make: Mitutoyo 3

Size: 12 S.L No Calibration Parameters Max. Allowable deviation 1 Internal Dia Measurement 0 ~ 300 mm ±(0.03mm) 2 External Dia Measurement 0 ~ 300 mm ±(0.03mm) 3 Depth Measurement 0 ~ 300 mm ±(0.03mm) DIGITAL VERNIER CALIPER Make: Mitutoyo Size: 6 S.L No Calibration Parameters Max. Allowable deviation 1 Internal Dia Measurement 0 ~ 150 mm +/- 0.021 mm 2 External Dia Measurement 0 ~ 150 mm +/- 0.021 mm 3 Depth Measurement 0 ~ 150 mm +/- 0.021 mm RTD Temperature Test Kit Make Model Working Max. Allowable deviation Make Model Working Max. Allowable deviation I APEX 18591 PDG -50 ~ 225 Deg C 0 ~ 100 Deg C ± 0.1 Deg c II APEX 18591 PDG -50 ~ 600 Deg C 0 ~ 300 Deg C ± 0.1 Deg c BORE GAUGE 4

Make: Mitutoyo Repeatability: 0.002 mm S.L No S.L NO Max. Allowable deviation 1 35 ~ 60 mm 573778 ± 2 micro meter 2 50 ~ 150 mm 591580 ± 2 micro meter 3 160 ~ 250 mm 620199 ± 2 micro meter 4 250 ~ 400 mm 602136 ± 2 micro meter DIGIMATIC DIGITAL BORE DIAL INDICATOR Make: Mitutoyo S.L.No: 44408 : 0 ~ 12.7 mm Max. Allowable deviation: ± 1 micro meter Repeatability: 0.5 micro meters Least Count: 0.001 mm Technical specifications for Temperature Bath: 5

Type Dry block portable microprocessor based temperature bath Make Nagman Model MP 40 R S.L NO MP 060211562-40 o C about ambient to +123 o C Max. Allowable deviation +/- 0.3 o C Stability +/- 0.05 o C Display type Digital Display 0.1 o C resolution Heating slope Programmable rate of 10-15 rate o C / min Cooling slope Programmable rate of 5-10 rate o C / min Temperature 7 min stability time Well diameter inserts of 4 mm to 12 mm dia Tester depth 100 mm depth Analog O/P Volt 10 mv DC / o C Accuracy +/- (0.03% fs) 0.003 V Measure DC Current 0 ~ 25 ma Accuracy +/- (0.05% fs) 0.01 ma Supply Volt to TX 24 V Dc Power supply 230 V AC, 50 Hz, Multifunction calibrator : Make : Eurotron 6

Model: Microcal 20 DPC Serial Number: 72334 a) Pressure Module: Sr.no Item to be calibrated 1) External Pressure Module 2) Internal Pressure module Calibration Accuracy 0 ~150 bar ± (0.025% range) Resolution 0.001 bar -900~2000 mbar ± (0.025% range) Resolution 0.01mbar b) Generation Function(Source): Srno Item to be Calibration Accuracy (% of Reading ) calibrated 1) DC mv -20 ~200 mv ± (0.01% of Reading +3 µ Volt) Res: 1µ Volt DC V -0.2 ~ 2V ± (0.01% of Reading +10 µ Volt) Res: 10µ Volt DC V -2.0 ~ 20V ± (0.01% of Reading +0.1 m Volt) Res: 100µ Volt 2) DC ma 0 ~ 50mA ± (0.01% of Reading +0.4 µ A) Res: 0.1µ Amp 3) Ω 0 500Ω ± (0.02%of Reading +20mΩ) Res: 1 mω Ω 0 5kΩ ± (0.02%of Reading +200mΩ) Res: 10 mω 4) RTD ( PT 100,IEC) -200 ~ 850 ± (0.01% +0.05) Res: 0.01 c)measurement Function: Srno Item to be Calibration Accuracy (% of Reading ) calibrated 1) DC mv -20 ~200 mv ± (0.02% of Reading +3 µ Volt) Res: 1µ Volt DC V -0.2 ~ 2V ± (0.02% of Reading +10 µ Volt) Res: 10µ Volt DC V -2.0 ~ 20V ± (0.02% of Reading +0.1 m Volt) Res: 100µ Volt 2) DCmA -5.0 ~ 50mA ± (0.01% of Reading +0.4 µ A) Res: 0.1µ Amp 3) Ω 0 500Ω ± (0.02%of Reading +12mΩ) Res: 1 mω 7

Ω 0 5kΩ ± (0.02%of Reading +120mΩ) Res: 10 mω 4) RTD ( PT 100,IEC) -200 ~ 850 ± (0.01% +0.05) Res: 0.01 8