Terminator DP/FAK-5 and FAK-5L

Similar documents
Terminator DP/FAK-4 and FAK-4L for In-Line Splice of Electrically Heated TubeTrace Bundles INSTALLATION PROCEDURES

Terminator DP/FAK-5LHT Kit for Tee Splice of Electrically Heated TubeTrace Bundles INSTALLATION PROCEDURES

Terminator DP/FAK-4LHT Kit for In-Line Splice of Electrically Heated TubeTrace Bundles INSTALLATION PROCEDURES

Terminator DP/FAK-2 and FAK-2L. Elbow Splice Kit for Electrically Heated TubeTrace Bundles INSTALLATION PROCEDURES

Terminator ZP/FAK-5 and 5L

Terminator ZP/FAK-1 Kit Electrically Heated TubeTrace Bundles

Terminator ZP/FAK-4L Kit Electrically Heated TubeTrace Bundles

Terminator. DP Power Connection Kit INSTALLATION PROCEDURES

Terminator TM DL Lighted Power Connection/End Termination Kit INSTALLATION PROCEDURES. For Power Connection or End Termination Applications

TracePlus. PCA Power Connection Kit INSTALLATION PROCEDURES. PCA-H for BSX, HTSX, KSX, HPT, FP PCA-V for RSX, TSX, VSX

TracePlus. VIL-6 End of Circuit Light Kit INSTALLATION PROCEDURES. VIL-6-H for BSX, HTSX, KSX, HPT, FP VIL-6-V for RSX, TSX, VSX

Terminator DL-S for use with BSX *, HTSX, KSX self-regulating, HPT power-limiting, and FP constant watt heating cables

PETK Power and End Termination Kit

SCTK INSTALLATION PROCEDURES. Splice Connection Termination Kit. SCTK-1 for BSX, RSX, VSX SCTK-2 for KSX, HTSX SCTK-3 for HPT, FP

PETK Power and End Termination Kit

FAK-7HTS High Temperature Tubing Bundle End Seal Kit INSTALLATION PROCEDURES

ZP-XP Power Connection Kit. Terminator. The Heat Tracing Specialists INSTALLATION PROCEDURES

Power Connection Kit Installation Instructions. Terminator DP-M for use with TEK and HTEK series constant watt heating cables

In-Line / T-Splice Kit Installation Instructions. Terminator DS-L for use with RSX, TSX, VSX self-regulating heating cables

PETK Power and End Termination Kit

SCTK Splice Connection Termination Kit

Power Connection Kit Installation Instructions. Terminator ZP-M for use with TEK and HTEK series constant watt heating cables

Electric Heat Tracing INSTALLATION PROCEDURES

TubeTrace Tubing Bundles

DEVI EasyConnect Heating Cable Connection System

Electric Heat Tracing INSTALLATION PROCEDURES

C Power Connection Kit

ET-PWR-END-KIT Installation Instructions (part #JSR00)

FLX TM Self-Regulating Winterization/Freeze Protection INSTALLATION PROCEDURES

DEF-Trac. Design and Installation Guide. August 2015

C A Heating Cable Gland Kit Installation Instructions

UPC Power Connection Kit

C A HEATING CABLE GLAND KIT INSTALLATION INSTRUCTIONS

PMKG-JS POLYMATRIX SPLICE CONNECTION KIT INSTALLATION INSTRUCTIONS

JBM-100-STB NEMA 4X-rated connection kit Installation Instructions

PRO-Tect Pipe Freeze Protection Self-Regulating Heating Cable Install Manual (PT-Series)

DEF-Trac. Design and Installation Guide. August 2014

SERGE BARIL HA-S HAZARDOUS AREA SEAL KIT

Products and Accessories. Information Guide

TSRT TSRT Tee Splice Kit Installation Instructions

PMKG-J2LP PolyMatrix Powered Splice Kit Installation Instructions

SRK02 Hard Wire Power Connection Kit. Installation, Operation and Maintenance Instructions

RT FlexiPanel TM Tank and Vessel Heating Panel

JBS-100-A, A6 SINGLE ENTRY POWER CONNECTION WITH JUNCTION BOX INSTALLATION INSTRUCTIONS

HTP PTP/ PTJ Power Connection Kit for Pipes

JBS-100-STB Single Entry Power Connection with Junction Box Installation Instructions

SPC-P Smart Power Connection with Temperature Monitoring Transmitter Pipe Mounted Installation Instructions

AutoMatrix Power Connection Kit. (1) This type 4X enclosure is intended for indoor or outdoor use primarily to. (2) May be required (see step 1).

EMK-XP ElectroMelt Power Connection and End Seal Kit Installation Instructions

Power Connection Kit installation instructions

Installation Instructions

CONTENTS. This Product is Certified by CANADIAN STANDARDS ASSOCIATION and Bears the Mark:

WarmTrace TM HSX Hot Water Temperature Maintenance INSTALLATION PROCEDURES

WarmlyYours ET-SR Series Heating Cable Installation Manual for Roof & Gutter Deicing

Specification for Heated Instrument Tubing in Process Applications* (March 29, 2007)

Ecoflex potable PEX plus pre-insulated pipe system Installation guide

Installation & Operation Instructions. Type USL Signal Light Kit for Self-Regulating Constant Wattage Heating Cables. Constant Wattage Grommet

UES-LL End Termination Kit

Universal Super Shield & Ultimate Aluminum w/electric Drive Conversion Kits , , Installation Instructions

POWERHEAT TYPE AHT TERMINATION INSTRUCTIONS. Ref TK/AHT Issue C Date 16 August 1999

Installation Instructions CONSTANT WATT (CW) AND SELF-REGULATING (SR) PIPE TRACING CABLES

PRODUCTS&ACCESSORIES INFORMATION GUIDE SELF-REGULATING HEATING CABLES HTSXTM BSXTM VSXTM RSXTM KSRTM KSXTM

TOYOTA VENZA 2009 TRAILER WIRE HARNESS Procedure

SPECIAL INSTALLATION INSTRUCTIONS

Nuheat WEATHER-READY HEAT TRACE PIPE FREEZE PROTECTION SYSTEM. Self-Regulating Heating Cable Installation Guide. UV Resistant Polyolefin Outer Jacket

Air Conditioner for M915 A0/A1 Truck

Assembly Instruction EL OCHITO WHITE CONTACTS 1000BASE-T/10GBASE-T TYPE I: PIN /SKT CABLE: S/FTP

Splicing Procedures 4. 2 Insert the new wire between the parted strands. If more than one wire is being spliced, wrap them in opposite directions. Use

WARNING TAKE NOTE OF THE FOLLOWING: THIS PRODUCT MUST BE INSTALLED EXACTLY AS PER THESE INSTRUCTIONS USING ONLY THE HARDWARE SUPPLIED.

TOYOTA VENZA 2009 TRAILER WIRE HARNESS Procedure

SynergEX Panelboards for Hazardous Locations

Installation Instructions

Pole Mount COD Installations (PMCOD)

Heating Cable. Description

Selection Guide. Freeze Protection Heating Cable. Thermwire - Wrap. Thermwire - Wrap Pre-Assembled. Thermwire - Comp. Thermwire - Melt.

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

LED Garage Light INSTALLATION INSTRUCTIONS. *Model number noted on carton label

Installation Instructions Electric Heaters 5 20 kw

Fiber Connector Shelf (CCS)

Installation Instructions Electric Heaters 5 20 kw

Installation Instructions

Type HLT Self-Regulating Heater Cable For use in Ordinary and Hazardous (Classified) Locations

Severe Duty Oil Filter Relocation Kit (OC-9)

MIQ MINERAL INSULATED HEATING CABLE INSTALLATION INSTRUCTIONS

COYOTE STP (Service Termination Point)

IP65 COOLEDGE TILE EXTERIOR R2 INSTALLATION MANUAL. Exterior TILE Jumper Cable. Exterior Cutout TILE. Cable Clamp. T-Cable.

SLiC Aerial Terminal and Spiral End Seal for use with AMP* Quiet Front Terminal Blocks

SWX-100-INT-PCR Internal Isolation Switch

3M Self Regulating Heating Cables

Power-Limiting Cables

MX Cable Connector Kit Manual Manual for Trimming the Cable and Connecting the Connector to an MX8031 Extension Cable

Product Installation Instructions. Raychem Corporation Electrical Products 8000 Purfoy Road Fuquay-Varina, NC 27526

LED Flat Panel Installation Instructions For 1 x4, 2 x2, and 2 x4 LED Flat Panels (FP Series)

PIPE FREEZE PROTECTION AND FLOW MAINTENANCE XL-TRACE SYSTEM

TOYOTA RAV TRAILER WIRE HARNESS Section I Installation Preparation

* * Inside Toyota Avalon. Tools Required IMPORTANT

AquaLumin III - Nicheless Light Installation Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Installation and Service Instructions for Self Adjust Brakes 81,000 Series

COYOTE CLOSURE ADOBE SERIES FOR UNDERGROUND, AERIAL, AND BURIED SPLICES 6.0" x 22" 8.5" x 22" (152.4 mm x mm mm x 558.

Rated for use on 110/120VAC 60Hz and 220/240VAC 60Hz applications

Transcription:

for T-Splice of Electrically Heated TubeTrace Bundles INSTALLATION PROCEDURES

The following installation procedures are suggested guidelines for the installation of the Terminator DP/FAK-5 and FAK-5L: T-Splice kit. Dimensions... A Receiving, Storing and Handling... 1. Inspect materials for damage incurred during shipping.. Report damages to the carrier for settlement.. Identify parts against the packing list to ensure the proper type and quantity has been received.. Store in dry location. Terminator DP/FAK-5 Kit Contents... 1 5 Terminator DP /FAK-5 A B B C 8-/ ( mm) 11-/ (99 mm) 11-5/8 (95 mm) C 6 Terminator DP /FAK-5L 10-1/ (67 mm) 11-/ (99 mm) 15-5/8 (97 mm) 7 9 10 11 1 1 Required: Order Separately for each heater to be fabricated. PETK Power and End Termination Kits (one req d. per heater) PETK-1D PETK-D PETK-D for BSX, RSX, VSX for KSX, HTSX for FP, HPT 1 5 8 1 15 6 Item Quantity Description 1 1 Expediter Assembly: Flat Mount, Grommet, Threaded Grommet Compressor, and Support Cap with O-Ring 1 Junction Box Lid 1 Junction Box with O-Ring 1 Nut 5 5 Terminal Block (Typical) 6 1 Junction Box Cord 7 1 () 8 1 () 9 1 Pan Head S.S. Screws, #10- x / 10 1 KEPT S.S. Nuts, #10-11 M5 Screw 1 M5 Lock Washer 1 1 Heat Refl ective Tape 1 1 Glass Fiber Tape 15 RTV Sealant Tube Item Quantity Description 1 1 RTV Sealant Tube 1 TBX Power Connection Boots 1 ET End Cap 1 Tape Strip Tefl on 6" (PETK-D only) 5 1 End Termination Caution Label 6 1 GRW-G Grommet (PETK-D only) Tools Required... Box Cutter Hacksaw Screwdriver Pliers

INSTALLATION PROCEDURES The Terminator DP/FAK-5 and FAK-5L T-Splice Kit is designed to make a waterproof seal over the end of TubeTrace at the t-splice connection. Review instructions prior to installation. Kit will make one splice connection (Tube fi ttings not included). See separate instructions for details on splicing heat tracing. Terminator DP Certifications/Approvals... IP66 NEMA/Type X -60 C Ta +55 C Ordinary & Hazardous Locations Class I, Division, Groups A, B, C, & D, Zone IIC Class II, Division, Groups F & G, Class III Listed System 17M Installation Precautions... To minimize the potential for arcing and ground-fault protection. The National Electrical Code (NEC) and Canadian Electrical Code (CEC) require ground-fault protection of equipment for each branch circuit supplying electric heat tracing. Installation must comply with Thermon requirements and be installed in accordance with the NEC, CEC, or any other applicable national and local codes. Component approvals and performance ratings are based on the use of Thermon specifi ed parts only. User supplied power connection fi ttings must be listed or certifi ed for intended use. De-energize all power sources before opening enclosure. Keep ends of heating cable and kit components dry before and during installation. Individuals installing these products are responsible for complying with all applicable safety and health guidelines. Proper personal protective equipment, or PPE, should be utilized during installation. Contact Thermon if you have any additional questions. Trim as Required for Connection 8mm (1.5 ) 8mm (1.5 ) Insulation Insulation 05mm -81mm (1-15 ) Bus Connection Indentation (Zone Heater Only) 05mm -81mm (1-15 ) 1. Remove outer jacket and insulation from tubing bundle to the required length for making connections. Do not cut or damage the heat trace or sampling tube. CAUTION (Found on TubeTrace SE/ME bundles) Self-Regulating. Trim heat tracing to within 05mm-81mm (1-15 ) of the end of the insulation. If selfregulating heat trace proceed to step. For Zone type heat trace continue with identifi cation of bus connection on step a. Zone Type a. Strip back bundle jacket and insulation 8mm (1-1/ ) to 76mm ( ) beyond bus connection indentation of each heat tracing. If bus connection indentation is less than 05mm-81mm (1-15 ) from end of the heat tracing, proceed stripping the bundle jacket and insulation to the next indentation. Glass Fiber Tape Heat Refl ective Tape Heat Refl ective Tape Tube Fitting. Make tube connections with appropriate fi ttings (provided by others). Test fi ttings for leaks before proceeding.. Wrap tube and heat trace with 1 pass of refl ective tape (5% overlap), then wrap with passes of glass fi ber tape (50% overlap), or until fi ber tape is equal to original bundle insulation thickness. 5. Complete with additional passes of heat refl ective tape.

Cut and Remove End Pieces to Fit Splice Cover Mounting Screws and Washers O-Ring Expediter RTV Sealant 6. Cut splice cover top and base to match outside diameter of tubing bundle and remove end pieces. Weep Hole 7. Mount Expediter with O-Ring to splice cover base using () mounting screws and lock washers. Punch out weep hole. 8. Form a gasket by applying RTV sealant to splice cover base and along radius of splice cover top as shown. Ground Braid Power Connection Boot Dimple for Center Line Drilled thru (1) Wall 9. Assemble splice cover top, tubing bundle, and splice cover base together as shown using 10- x / pan head screws and KEPT nuts. 10. Terminate heat tracing with appropriate PETK termination kit. Refer to PETK installation instructions for details (not addressed here). 11. For power connection applications: Use dimple molded into side of junction box base to locate center hole, drill for user supplied power connection fi tting per manufacture s recommendations. Align Slot Terminal Blocks (Typical) 1. Mount junction box on expediter making sure to align slots to properly orient junction box base. 1. Install quick mount terminal blocks twist to position and tighten screws. 1. Complete system wiring between fabricated heat tracing and power supply wiring. See wiring diagrams on Page 5.

INSTALLATION PROCEDURES 0º Power Connection (1 to Cables). For cable power connections, additional terminal blocks will be required when using 10mm (#8 AWG) power supply wiring. In-Line Splice and T-Splice 15. Install junction box lid and twist hand tight. Insert screwdriver into ratchet slot located on side of junction box base to tighten. Lid will rotate 0º. Splice Cover Junction Box 16. Lid latch mechanism fully engaged. To remove lid, repeat steps 15 and 16 but in opposite direction. 17. Completed Terminator DP/FAK-5 for T-Splice of Electrically Heated TubeTrace Bundles. (Installation shown is to feed power in kit junction box. Many installations will be for splice only, without power feed to the electrical heat tracing circuits.) THERMON... The Specialists 100 Thermon Dr. PO Box 609 San Marcos, TX 78667-0609 Phone: 51-96-5801 Facsimile: 51-96-67 1-800-80-HEAT In Canada call 1-800-56-861 For the Thermon offi ce nearest you visit us at... www.thermon.com Specifi cations and information are subject to change without notice. Form PN50058-061