KS Pump Stations. Engineering Submittal Sheet. Installation Sets for Collectors

Similar documents
Valves, controls + systems Valves and controls for solar installations Regusol-180

UNIT TAG: TYPE OF SERVICE: SUBMITTED BY: APPROVED BY: ORDER NO.: UP B5. Circulator pumps. Motor Data Flow: Head: Efficiency: Pump Data

Installation instruction

COMPONENTS FOR SOLAR THERMAL SYSTEMS

Solar Thermal. Grant Solar Pump Station Installation & Servicing Instructions

Product range Solex Technical data and dimensioning. 5 Years

OPERATION AND INSTALLATION

UNIT TAG: TYPE OF SERVICE: SUBMITTED BY: APPROVED BY: ORDER NO.: MAGNA F N. Pump Data

SOLAR HEATING SYSTEM

SOLAR THERMAL EQUIPMENT

Pump Stations for Heating Circuits

INSTALLATION AND COMMISSIONING MANUAL CONTENTS. Function. Product range. Technical specifications. Characteristic components

CIRCO5SolarCirculationUnit

Air-to-water heat pump for indoor installation - LIK 8TES. Spare parts list

INSTALLATION AND COMMISSIONING MANUAL CONTENTS. Function. Important Product range Technical specifications

BULLETIN BAQSOLO AQUAVAR SOLO CONSTANT PRESSURE CONTROLLERS FOR: 1Ø 3-WIRE MOTORS, 1Ø 2-WIRE CENTRIPRO MOTORS, 3Ø MOTORS

COMPONENTS FOR SOLAR THERMAL SYSTEMS

This catalog contains the following geothermal accessory products and specification guides:

earth safe Fuel Systems for Critical Power

CALEFFI. Solar pump stations 01166/14 NA. 278 and 279 series 01264/16 NA

.2 Section Waste Management and Disposal..5 Section Thermometers and Pressure Gauges Piping Systems.

SECTION PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY

SECTION VALVES PART 1 -GENERAL

DWO DWO DWO DWO

DISTRIBUTION GROUP WITH THERMOSTATIC REGULATION. Upper connections G1 F Without fittings Fittings with running connection* Without pump

SECTION COMPRESSED-AIR PIPING FOR LABORATORY FACILITIES

IsoTherm FlowGuards Mini Ball Valves Gauges Aquastats Unions

SECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING

CDU. Model CDU Contents. EBARA Stainless Steel Centrifugal Pumps

Submittal Data 3450 RPM 60 Hertz JOB or CUSTOMER:

LK Manifold Shunt VS 2-2,5

Selection Chart Project: Model: Chk d: Date: C C V V V A CAPACITY

SECTION GENERAL-SERVICE AIR COMPRESSOR PART 1 - GENERAL

Datasheet. Flamcomat - Pressureless Expansion System

Item No. Specifications Selection Performance Pump Sectional View Chart Curve Dimensions

A. American National Standards Institute: 1. ANSI Z Relief Valves for Hot Water Supply Systems.

LK Manifold Shunt VS2

Catalogue Solar stations DN 20. Solar thermal solutions. Valid for the UK

1. Air Handler Features Page Physical data Page Available kits Page Model nomenclature Page 5

FFW/FSW/FHW SERIES FLOOR EXPOSED VERTICAL FAN COIL UNITS

Solar water pumping system Goulds, 0.75HP 230Vac, 120psi Test Report -

Supply Return. Pumping station 2-way "Solar 2" _!':'! _. Directions for the use of the flowmeter to fill the installation:

Mercy Hospital of Buffalo Catholic Health System 2 nd Floor Patient Holding Center 3 rd Floor Locker Rooms Shaflucas Architects, PC Project No.

4-Way Mixing Panel Submittal - Page 1 of 6

GUIDE FOR CHOOSING AN ACCUMULATOR TANK

Multi-Tank Submersible Pump Install Manual

Single-Valve Powerstation

PRESSURE CONTROL VALVES SABS 198

G03 Mono-Block Series

PRODUCT CATALOG. Alternate Energy Technologies, LLC

JE1, JE1 4 SERIES CONTENTS: Stainless Steel Construction Closed impeller Flow: 8 to 95 GPM Head: to 144 ft. Range of HP: to 3 HP

Pilot Operated Pressure Relief Valve Series R5V (Denison)

2CDU70/206-2HP 2CDU70/306-3HP CDU120/306-3HP 2CDU200/506-5HP 607

XCITE Owner s Manual. Reso-not TM Damping System XCITE 1502C HYDRAULIC POWER SUPPLY

AIR OPERATED DOUBLE DIAPHRAGM PUMP

G04 Series. Maximum Flow Rate: 11.2 l/min (2.9 gpm) Maximum Pressure: 200 bar (2900 psi) for Metallic Pump Heads. G04 with Stainless Steel pump head


G20 Series. G20 Close-coupled with Brass pump head ATEX. G20 Version 1 01/15

Underground Tank Applications Installation Guide

Valves, controls + systems Stations for the connection heat generator/heating circuit

Residential R.O. components

G20 Series. 24 bar (350 psi) for Non-metallic Pump Heads. G20 Close-coupled with Brass pump head ATEX. G20 Version 5 10/16

AIR OPERATED OIL PUMPS AND KITS

Fleck Epoxy Lined Section 2 Steel Softeners

EVOTRON SAN WET ROTOR ELECTRONIC CIRCULATORS TECHNICAL DATA

G15 Series API bar (2500 psi) for Metallic Pump Heads. G15 for horizontal installations shown with Stainless Steel pump head.

Air-Cooled Screw Compressor Chiller

G10 Series API bar (350 psi) for Non-metallic Pump Heads. G10 with Cast Iron pump head

Zone manifold DN 25, DN 32, DN 50. Mounting and operating instructions

B Series Multi-Position & Hydronic Air Handlers Electric or Hot Water Heat, with available Variable-Speed High Efficiency ECM Motor

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS

FIRE PUMPS F AI LISTED R LISTED N K S MOR S E P U IT Y S Y S T E M CE R T IF IE D

ADVANCE. 2 Pole Impeller PUMPS PUMPS

AIR OPERATED OIL PUMPS AND KITS

D05 Directional Control Valves

Atomizer 36-DC User Guide

Check Valves Check Valves are the simplest form of directional control valves, but they can also be used as pressure controls.

LACT MEASUREMENT. Total Head = Or PSI = S.G. 2.31

A13 AVILA RANCH DEVELOPMENT PLAN SITE PLAN. Typical 58 R-1 Residential Street Section STREET SECTION. July 19, 2016 #

Raptor 085HB-270HB & 155CB Submittal

P.T.O. INSTALLATION 1 2 For manual shift transmissions, drain transmission fluid. For automatic transmissions, do NOT drain transmission fluid. Remove

SBS Manual for the specialised craftsman. Filling and flushing station. Connection Operation. en Manual

SOLAR WORLD, INC. INSTALLATION MANUAL

GRUNDFOS PRODUCT GUIDE LM, LP. Single-stage close coupled in-line circulating pumps 60 Hz

RA / Pressure Reducing Valve, Pilot Operated Model DR (Series 5X) Ordering code 1/ PSI (350 bar) GPM (400 L/min)

UPGRADE PROGRAM. V141 Series Pumps vs Turbo-301 Series Pumps. Technical Memo

Multi-Institutional Academic Health Science & Research Center Evansville, IN

SP 700 EC-TH / 730 EC-TH / 730 EC-EV

HORIZONTAL MULTISTAGE CENTRIFUGAL ELECTRIC PUMPS

S1 SERIES TECHNICAL DATA INFORMATION PACKET

Hot Water Generator Systems Water to Water Steam to Water. Horizontal or Vertical Jacketed & Insulated

RSV Series In-Line Vertical Multi-Stage, Ring Section Pump September 2013

INLINE 1100 COMPACT, MULTI-PUMP SYSTEM. franklinwater.com

Non-Imaging Concentrator based Solar System Operations & Maintenance Manual

SECTION GENERAL-DUTY VALVES FOR HVAC. A. Section includes valves for building services piping.

Foaming of Lubricating Oils (manual)

Product Instructions. Mixing Station. Features. Specifications. Materials

HORIZONTAL SPLIT CASE SINGLE STAGE DOUBLE SUCTION Type AE CHECKING LIST

AV 23 Balancing valves SETTER Inline

AXIAL PISTON MOTORS SHMF

Transcription:

Engineering Submittal Sheet Installation Sets for Collectors Layout legend S Supply from collector to storage R Return from storage to collector 1 Ball valve with thermometer and integrated gravity break Position 0 = gravity brake ready for operation, ball valve open Position 45 = gravity brake manually open Position 90 = ball valve closed 2 Compression ring fitting (all flow and return connections) 3 Safety relief valve 4 Pressure gauge 5 Connection for diaphragm expansion vessel 6 Fill & drain valve 7 Solar circuit pump 8 Flow volume indicator 9 Air separator Engineering Specifications The following shall be the specifications for the solar pump station. The solar pump station shall be a KS0105, KS0110, KS0120, or KS0150. The station shall have a rear and a front insulation with the following dimensions: Height 14, Width 11-1/2, Depth 9-1/4. The pump station shall be equipped with a 120V 60Hz Grundfos solar pump 15-58 (KS0105 and KS0110), Grundfos UPS 25-99 (KS0120), and UPS 25 120 (KS0150). The pump station shall be equipped with a supply and a return shutoff ball valve with thermometer integrated into the handle. Furthermore it shall have a manual air separator, a flow check/ gravity brake, flow setter with volume flow indicator, 87 psi rated safety relief valve, and ¾ expansion vessel connection (KS0150: 1 ). 1 of 6

KS Pump Station Specifications Technical Specifications KS0105 KS0110 KS0120 KS0150 Part number 7747021981 7747021982 7747021983 8718530311 Max. recommended # of collectors 5 10 20 50 Copper pipe connection size (compression fitting) Supply/Return ½ ¾ 1 1 Expansion tank connection ¾" ¾" ¾" 1 Safety relief valve (bar) 87 psi (6) 87 psi (6) 87 psi (6) 87 psi (6) Circulation pump type Grundfos Solar 15-58 Grundfos Solar 15-58 Grundfos UPS 25-99 Grundfos UPS 26-120 Circulation pump finished length (mm) 5 ⅛" (130) 5 ⅛" (130) 7 1/16" (180) 7 1/16 (180) Electrical power supply 120 V AC 120 V AC 120 V AC 120 V AC Frequency 60 Hz 60 Hz 60 Hz 60 Hz Max. power consumption 60 W 125 W 195 W 215 W Max. current load 0.25 A 0.54 A 0.85 A 2.15 A Throughput limiter adjusting range (L/min) ⅛ - 1½ gpm (0.5-6) ½ - 4¼ gpm (2-16) 2-7 gpm (8-26) 5-11 gpm (20-42.5) Weight (kg) 16 lbs. (7.1) 16 lbs. (7.1) 21 lbs. (9.3) 22 lbs. (10.0) KS Pump Station Dimensions KS Pump Station Dimensions Dimension (mm) KS0105 KS0110 KS0120 KS0150 Height 14" (355) 14" (355) 14" (355) 14" (355) Width (B) 11½" (290) 11½" (290) 11½" (290) 11½" (290) Depth (T) 9 ¼" (235) 9 ¼" (235) 9 ¼" (235) 9 ¼" (235) (A) 5 ⅛" (130) 5 ⅛" (130) 5 ⅛" (130) 5 ⅛" (130) (C) 3 ⅛" (80) 3 ⅛" (80) 3 ⅛" (80) 3 ⅛" (80) (E) 2" (50) 2" (50) 2" (50) 2" (50) 2 of 6

KS 105 and KS 110 Pump Curve 20 18 16 14 HI MED Without Check Valve With Check Valve Head (ft.) 12 10 8 LOW 6 4 2 0 0 2 4 6 8 10 12 14 16 18 Flow (GPM) KS 105 and KS 110 Technical Data Flow range 0 17.5 gpm Head range 0 19' Motors 2 pole, single phase Maximum fluid temperature ( C) 230 F (110) Minimum fluid temperature ( C) 36 F (2) Maximum working pressure 145 psi 3 of 6

KS 120 Pump Curve 30 25 20 HI MED Without Check Valve With Check Valve Head (ft.) 15 LOW 10 5 0 0 5 10 15 20 25 30 35 Flow (GPM) KS 120 Technical Data Flow range 0 34 gpm Head range 0 32' Motors 2 pole, single phase Maximum fluid temperature ( C) 230 F (110) Minimum fluid temperature ( C) 36 F (2) Maximum working pressure 145 psi 4 of 6

KS 150 Pump Curve KS 150 Technical Data Flow range 0 19 gpm Head range 0 38' Motors 2 pole, single phase Maximum fluid temperature ( C) 230 F (110) Minimum fluid temperature ( C) 36 F (2) Maximum working pressure 145 psi 5 of 6

Pressure Drop Curve for n-collectors 6 of 6