On/Off- Solenoid to RL 94/9/EG (ATEX 95) G HP E Pamphlet

Similar documents
On/Off- Solenoid to RL 94/9/EG (ATEX 95) G HP E

Proportional Solenoid for Hydraulics ATEX + IECEX

Proportional Solenoids for Hydraulics G RC Y 037, 045, 063

Electromagnetically actuated shotbolt lock unit G SC X... B01

Proportional solenoid valve for pneumatic application V PR M

DC Single-Acting High Performance Solenoids

Proportional solenoid valve for pneumatic application V PR M

Type 60,61L. Electric Bolt Lock - Industrial

Solenoid Operator 0516 / 1216

Solenoid Operator 0513 / 1213

Proportional Solenoids

Pilot-Operated Directional Control Valves Series D3 - D11

3/2 Way Valve G1/8. Data Sheet No E. Characteristics Symbol Unit Description General Features Spool valve.

Solenoid System KNURLED NUT TOP CORE GUIDE TUBE PLUNGER

Directional Control Valve Series D3W Soft Shift

MN-06. Standardized valve series 3/2-way acc. to NAMUR, 750 Nl/min (0.762 Cv) Technical data for series. Order code MN HN-142

Series 26d Ball Valve

GEMÜ 205 Electrically operated solenoid valve

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm

3/2 and 4/2 directional seat valves with solenoid actuation

COMBISTOP NEW. Spring applied brakes

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

MN-06. Standardized valve series 3/2-way acc. to NAMUR, 750 Nl/min (0.762 Cv) Technical data for series. Order code MN HN-142

p max (see table of performances) Q max (see table of performances) bar Maximum flow l/min see par

System 8. Solenoid Coils Armature Assemblies Valve Systems. Nass Controls LP Nass Magnet GmbH Precision Controls Kft.

For double-acting actuators. Crossover-free switching. Safety function in the event of power failure provided by mechanical return spring

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

Lifting / Lowering valve type HSV and HZV

3/2-way Solenoid Valve for pneumatics

For single and double operated actuators. Exhaust air recirculation (3/2 way function)

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator

Solenoid System FLANGE MOUNTING VERSION

3/2-way Rocker Solenoid Valve for pneumatic systems

System Line. AC Single-Stroke Solenoids

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

4/3 proportional directional control valve, without position control, with on-board electronics (OBE)

97100 NAMUR. Technical data

Technical Data Sheet

Installation and Operating Instructions for ROBA-stop -silenzio Type 896. _. Sizes

4/3, 4/2 and 3/2 Directional Valve with Wet-pin AC or DC Solenoid

Pilot Operated Directional Control Valves Series D31DW, D41VW - D111VW

Lifting / Lowering valve type HSV

To order, quote model number from table overleaf, e. g for a DN 25 valve.

Directional Control Valve Series D1VW

2/2 or 3/2-way Solenoid Valve, with pivoted armature and isolating diaphragm

Installation and Operational Instructions for ROBATIC -clutch Types _.0 and _.0 Sizes 3 7

Lenze. Drives with worm gearboxes 52.

Our policy is one of continued research and development. We therefore reserve the right

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

Holtumsweg 13, D Weeze, Tel /9134-0, Fax /1444

4/3-4/2 Proportional directional valves L5080 solenoid (LC04P) operated (for open loop control) L5080 (LC04P)

Type 3761 Pneumatic or Electropneumatic Positioner for Rotary Actuators. Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

EVI 5 S13 Solenoid System

3-Way Solenoid Valve - Direct Acting

Operating instructions Solenoid interlock EX-AZM About this document. Content

Special valves. Series. Solenoids. IP65 (with connector) Zones 1, 21 II 2 G II 2 GD EEx me IP64. Aluminium. Operation. Page no. EEx me IP65.

Electrically Released Brakes ERS VAR11-01 FT = 4100 N

DL /118 ED SOLENOID OPERATED DIRECTIONAL CONTROL VALVE COMPACT VERSION SUBPLATE MOUNTING ISO p max 280 bar Q max 50 l/min

Miniature coil (3W) encapsulated in synthetic material. Connection with 3-pin DIN type B plug. Degree of protection IP 65.

COMBIBOX. Program Schedule. Design. COMBIBOX clutch-brake-combination type 10 / 09 / 06. Attachments

Type 0283, Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-way solenoid valve 2/2-Wege-Magnetventil Électrovanne 2/2 voies

Drain ball valve BR 21a

15 mm Pilot Valve. More technical specifications are reported in the following pages. 1

HERION SERIES Indirect solenoid actuated soft seal

Solenoid valve VDHT standard BSP (British Standard Pipe)

System 13. ü ( System 13

Ex m Solenoid Operator Type 0519

Valves For Process Industry. Engineered Pneumatic Solutions.

Solenoid valves VZWM-L, NPT

3/2 and 4/2 directional seat valves with solenoid actuation

Solenoid System. The coil is also in conformity with 94/9/EC ATEX for electrical apparatus of group II, category 3 (Ex na II 3 GD T4 or T5).

System 6. Solenoid Coils Armature Assemblies Valve Systems

Installation and Operating Instructions for ROBA-stop -silenzio Type 896._3_. Sizes

2/2-way valves DN 8 to DN 50

High-pressure switch for gas, air, flue gases and combustion products GW A4/2 HP

System 6. ü ( System 6

4/3, 4/2 proportional directional valves solenoid operated (for open loop control)

Installation and Operational Instructions for ROBA-stop Holding Brake Type _._

APPLICATION OF SYSTEM 8

Delta HE 35-XX, 55-XX

Pilot Operated Directional Control Valves Series D31DW, D31NW, D*1VW

97100 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT

Pneumatic or Electropneumatic Positioner for Rotary Actuators Type Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

Our policy is one of continued research and development. We therefore reserve the right

BUSCHJOST SERIES

Operating Instructions

97105 Inline. Ordering information. Technical data. Accessories See page 5

Data sheet. Solenoid valves 2/2-way direct-operated Type EV210B. February 2002 DKACV.PD.200.A B1504

2/2-way proportional seat valve

/2-way piston valves

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Pilot control unit with end position lock for the remote control of directional valves

Solenoid valve type 150 direct action

Type 5411, Operating Instructions. Bedienungsanleitung Manuel d utilisation

Limit switch attachments DAPZ

BR 26d Ball valve. Stainless Steel. Application: Versions: Special versions:

2/2-way Solenoid Valve with servo diaphragm, G 3/8 - G 2

Mounting and Operating Instructions EB 8111/8112 EN. Valve Series V2001 Globe Valve Type 3321

Solenoid valves VUVS/valve manifold VTUS, NPT

Transcription:

SPECIALISTS IN ELECTROMAGNETIC SOLENOIDS DEVICESAND SOLUTIONS On/Off- Solenoid to RL 94/9/EG (ATEX 95) 4 Product Group G HP E Pamphlet To DIN VDE 0580 and RL 94/9/EG (ATEX 95) Pressure-tight armature space, rated operating pressure 250 bar Magnetic force/stroke characteristic Quick floating times Pushing type Mounting via central thread Simple exchange of the coil without opening the hydraulic circuit Coil winding to insulation classification H Electrical connection and protection class if mounted properly: Connection cable Li12Y11Y 3 x 1.5 Protection class to DIN VDE 0470/EN 60 529 - IP67 Explosion protection II 2G EEx m II T4 Supplementation of permission for dust guard, 2D, is being prepared. Manual override Modifications and special designs on request Application examples: Actuation of hydraulic and special valves Fig. 1: G HP E 037 AMX A01 Magnet-Schultz GmbH Limited & Co. Postfach 3-4 Capital 1665 Park D 87686 Memmingen Old Woking Allgäuer Surrey Straße 30 GU22 D 87700 9LD Memmingen UK Phone: Telefon ++44 ++49 (0) (08331) 1483 794700 104-0 Fax: Telefax ++44 (0) ++49 1483 (08331) 757298 104-333 sales@magnetschultz.co.uk VTF@msmsm.com www.magnetschultz.co.uk www.msmsm.com

SOLENOIDS AND SOLUTIONS sales@magnetschultz.co.uk Technical Data G HP E 037 AMX A01 Operating mode S1 (100 %) FM N Rated Voltage UN Rated Current IB Rated Power P20 Ambient temperature Ta 24 V 0.72 A 17.3 W - 20 to + 50 C 80 70 60 50 40 30 Mounting on hydraulic valve with multiple mounting in single operation: minimum size: 46 x 46 x 66 mm on base plate material: iron or material with equal, or better heat derivation respectively. The indicated technical data refer to a power supply from the A.C. mains supply via bridge rectifier. By appropriate measures it is to be ensured that the given maximum values, especially the control current level, are not exceeded. On request the coil winding can be adjusted to other current and resistance values. The magnetic-force values in the diagram refer to 90 % of the rated voltage (UN = 24 V) and in hot condition, according to DIN VDE 0580. For other voltages the magnetic force may deviate. Owing to natural dispersion the magnetic-force values may deviate by + 10 % from the listed values. On request, the armature space can be de-aerated and the pushrod can be adjusted. Mech. modifications of the flange are possible on request. The solenoid interior and armature bearing are resistant to all neutral fluids that are commonly used in hydraulics. 20 10 0 0 0,5 1,0 1,5 2,0 2,5 3,0 3,5 4,0 s mm Fig. 2: magnetic force / stroke characteristic G HP E 037 AMX A01 Please notice the relevant operating manuals which are delivered with each device. An EC declaration of conformity of the manufacturer is enclosed once. Please be sure that this device ist suitable for your application. We kindly ask to notice the DIN EN 60079-14 for the application. Please contact us if you intend to use other operating media. 2 Data may be changed without The notice edition of dimensions the present pamphlet not guaranteed. cancels the former Subject ones. to our Standard Conditions

sales@magnetschultz.co.uk SOLENOIDS AND SOLUTIONS Magnetic Body (dimensions for your information) disc min. 0.1 jutted out Fig. 3: Coil 924618 (FHMPE037924618) inscription according to LB924617 37 Tube (dimensions for your information) closing torque 12 tp 14 Nm emergency manual override actuation force max. 20 N without pressure energized armature Fig. 4: Tube 923692 (FHTP037923692) Data may be changed without notice dimensions not guaranteed. Subject to our Standard Conditions 3

sales@magnetschultz.co.uk SOLENOIDS AND SOLUTIONS Proportional Solenoid, complete cable + end sleeve DIN 46228 - A 1.5-7 connecting line Li12Y11Y 3 x 1.5 mm² round sealing ring 19 x 2.5 70 Sh-A NBR FHTS923692 FHMSE037924617 fixing nut closing torque 5 +1 Nm fitting socket wrench set SW 26 (12 kt DIN 3124) Wiring diagram Fig. 5: Proportional Solenoid G HP E 037 AMX A01 Data may be changed without notice dimensions not guaranteed. Subject to our Standard Conditions 4

sales@magnetschultz.co.uk SOLENOIDS AND SOLUTIONS Single Components consecutive number quantity description Ident-No. 1 1 magnetic body f. 24 VDC FHMSE924617-001 2 1 tube FHTS037923692 3 1 round sealing ring 19 x 2.5 70 Sh-A NBR 781754 4 1 fixing nut 472793 Fixing Nut Fig. 6: Fixing Nut 472793 suitable socket wrench SW26 (bihex DIN 3124) O-Ring to be used: 19 x 2.5 70 Shore A closing torque 5 +1 Nm Data may be changed without notice dimensions not guaranteed. Subject to our Standard Conditions 5

SOLENOIDS AND SOLUTIONS sales@magnetschultz.co.uk Type code Equipment group Basic construction Modifications Size Arrangement Basic protection Design number G HP E 037 A MX A01 Only available as complete unit! Order Example Type Voltage Operating mode G HP E 037 AMX A01 24 V DC S1 (100% ED) Specials Special designs and modifications are available on request for which full application conditions should be specified in accordance with our -Technical Explanations. Data may be changed without notice Subject dimensions to our standard not guaranteed. conditions. Subject to our Standard Conditions 6 Printed in Germany 0804/04 Ss