Temposonics ATEX. Magnetostrictive Linear Position Sensors. DATA SHEET High Pressure Housing (HPH) The Measurable Difference

Similar documents
Temposonics. Magnetostrictive Linear Position Sensors. TH Analog Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. TH CANbus Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. TH Analog SIL 2 capable Data Sheet

Temposonics. MH-Series Analog Redundant. Absolute, Non-Contact Positions Sensors. Temposonics MT Measuring length mm

Temposonics Magnetostrictive Linear Position Sensors. Temposonics E-Series Brief Instructions

Temposonics. G-Series Analog or Start/Stop. Absolute, Non-Contact Position Sensors. Temposonics GP and GH Stroke length mm depends on output

Temposonics. Absolute, Non-Contact Position Sensors. MH Series. Temposonics MB Analog. Technical Data / Description

Temposonics. Magnetostrictive Linear Position Sensors. DATA SHEET GBS Analog

R-Series Rod Model RS. Data Sheet. Model RS Rod-style sensor with IP68/IP69K Super Shield Housing. Interrogation Return wire.

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

Level Plus. Magnetostrictive Liquid Level Transmitters with Temposonics Technology. LP-Series SE Replacement Installation Manual

Temposonics Magnetostrictive Linear Position Sensors. Temposonics GB-Series Brief Instructions

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

Temposonics. Magnetostrictive Linear Position Sensors. MH-Series MH5 Analog Data Sheet

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

Temposonics. Magnetostrictive Linear Position Sensors. MHRM Analog Data Sheet. For embedded or externally threaded installation

Temposonics. G-Series Analog Redundant. Magnetostrictive Position Sensors. Redundancy for enhanced safety

Temposonics. M-Series PWM. Absolute, Non-Contact Position Sensors. Temposonics MH Measuring Length mm. Document Number Revision B

Temposonics. Absolute, Non-Contact Position Sensors. OPERATION MANUAL R-Serie Analog. The Measurable Difference

Temposonics. M-Series Analog Redundant. Absolute, Non-Contact Positions Sensors. Temposonics MT Measuring length mm

Temposonics. M-Series Analog. Absolute, Non-Contact Position Sensors. Temposonics MH Measuring length mm. Compact Sensor for Mobile Hydraulics

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

Temposonics. E-Series Analog + Start / Stop. Magnetostrictive Position Sensors. Temposonics EP Measuring range mm / mm SENSORS

Temposonics. M-Series Analog. Magnetostrictive Position Sensors. Temposonics MH Measuring length mm SENSORS

ANALOG. PARAMETER SPECIFICATION Measured Variable: Displacement, Velocity (magnitude only) 16 bit or mm, whichever is greater

Temposonics. M-Series Analogue / SIL2* Absolute, Non-Contact Position Sensors. Temposonics MH Measuring Length mm

Temposonics. Absolute, Non-Contact Position Sensors. MH Series. Temposonics MH Analog /Digital. Technical Data / Description

Temposonics. R-Series Analog. Absolute, Non-Contact Position Sensors. Temposonics RP and RH Measuring length mm

SSI. Synchronous Serial Interface

Temposonics. Absolute, Non-Contact Position Sensors. MH Series. Temposonics MH 200. Technical Data / Description. Compact sensor for mobile hydraulics

Temposonics. R-Series DeviceNet. Magnetostrictive Position Sensors. Intelligent Design. Temposonics RP and RH Measuring length mm SENSORS

Temposonics. Magnetostrictive, Absolute, Non-contact Linear-Position Sensors. R-Series Models RP and RH DeviceNet Output.

Temposonics. Magnetostrictive Linear Position Sensors. MH-Series Flexible MH Installation Manual

CANBUS G. Up to mm ( in.) < ± 0.01% of full stroke or ± 0.04 mm ( in.), whichever is greater*

Temposonics. Magnetostrictive, Absolute, Non-contact Linear-Position Sensors. R-Series Models RP and RH Ethernet POWERLINK.

Terminal Boxes Series 8125

L E V E L P L U S M - S E R I E S ANALOG

Control Buttons / Switches for Panel Mounting Series 8003

Temposonics. Magnetostrictive Linear-Position Sensors. R-Series Model RP and RH Sensors Synchronous Serial Interface (SSI) Output D

Temposonics Magnetostrictive Linear-Position Sensors

PRODUCT SELECTOR GUIDE

PRODUCT SELECTOR GUIDE

Assembly. Trunk IN + - S U, I U, I. Spur 1

Part No Rev. E

Ex Pressostat EXPK 944/947/953. Applications. Features

ABG Cable Glands Installation Procedure

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Differential pressure transmitter PASCAL Ci4 Delta P

EEX Line Spring-applied single-disc brake for potentially explosion hazardous areas

Temposonics. Magnetostrictive Linear Position Sensors. ET Start / Stop ATEX / IECEx / CEC / NEC Certified Operation Manual

Compact Sheet-Steel Light Fittings Series 6114/1

Position Switches Series 8060/2

Terminal Boxes Series 8125

Sentronic PLUS 614 Series

Position Switches Series 8074/2

Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF)

Position Switches Series 8070/2

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

HKH Series. HAZCON Controls for Harsh and Hazardous Environments

Linear fluorescent luminaire LED V-CG-S

Direct-acting 2/2-way plunger valve

New products Ex Equipment 2015

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

Accessories for pneumatic stroke and rotary actuators CLASSIC and ELEMENT process valves

Temposonics. Magnetostrictive Linear Position Sensors

Flow switches Series AD/VH

Type MR 783 Magnetic level switch

Direct-acting 3/2 way plunger valve

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC

HKH Series. HAZCON Controls for Harsh and Hazardous Environments

Control switch/load disconnect switch Series 8008

Compact Sheet-steel Emergency Light Fitting Series 6118/1

Floodlight LED Series 6525

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

V82 series - Redundant valve manifold systems - Compact 1oo2 Safety, 2oo2 Availability and 2oo3 Safety and Availability

Kopex-Ex cable glands offer superior protection in hazardous environments

INSTRUCTION MANUAL (ATEX / IECEx)

Temposonics. Magnetostrictive Linear Position Sensors

Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip

SATRON VDt Differential Pressure Transmitter

Linear luminaire with LED Series EXLUX 6002

Resistance thermometer For additional thermowell, flameproof enclosure (Ex d) Model TR10-L

COMBUSTION AND ENERGY

Thermocouple For additional thermowell, flameproof enclosure (Ex d) Model TC10-L

Thermocouple For additional thermowell Model TC10-B

Ex m Solenoid Operator Type 0519

E II 3 (1) G Ex na [ia Ga] IIC/IIB T4 Gc

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Fieldbus Segment Protector F2-SP-IC* Features. Assembly. Function. Connection. Zone 2 Div. 2

Resistance thermometer Without thermowell Model TR10-H

Emergency Light Fitting for Fluorescent Lamps Series 6009

Operating Instructions

Terminal Boxes in Stainless Steel SLS**.T

Linear Luminaire with LED Series EXLUX 6002

Linear Luminaire with LED Series EXLUX 6402/2

Floodlight LED Series 6125

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases

STAINLESS STEEL PANEL MOUNT

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

Transcription:

Temposonics Magnetostrictive Linear Position Sensors DATA SHEET (HPH) ATEX The Measurable Difference

PRECISION POSITION MEASUREMENT HPH This (HPH) is ATEX-IECEx as well as UL and cul approved for use in hazardous locations with Temposonics position sensors. The ATEX, UL and cul approvals cover flammable gases, vapors, liquids and dust. This housing is made to fit Temposonics G-Series analog + start/stop sensors and R-Series sensors with analog and digital outputs. Both fixed cable and connector versions can be used. When using a standard sensor in this housing you get a cost efficient solution for use in hazardous locations which also allows easy sensor replacement. Several design combinations are available to fit your application: M18 or ¾"UNF mounting flange M20 or ½" NPT cable gland thread top mounted or single/dual side-mounted See design combination chart. All parts are made of 316L stainless steel. The housing is also available in non-approved versions ensuring an outstanding protection to the sensor when used in rigged applications with high humidity and agressive gases. HPH ROTATION ADAPTOR This adaptor allows you to adjust the position of the side opening when the HPH housing is mounted in a cylinder. The adaptor is pressure tested to 600 bar/8400 psi. RTA-M18 is for use with the standard M18 housing thread and has a M30 1.5 mounting thread. RTA-3/4" UNF is for use with the 1¾" UNF housing thread and has a 1 1/16" UNF mounting thread. 253 961 is for use with the 3/4 UNF housing thread and has a 1 ¼ UNF mounting thread. TECHNICAL DATA ATEX, IECEx TÜV 13 ATEX 121172 X IECEx TUN 13 0011 X II 1/2 G Ex d IIC T5 Gb II 1/2 D Ex tb IIIC T100 C Db T amb -40 to +75 C (1) In accordance with EN 60079-0, EN 60079-1, EN 60079-31 Only with ATEX and IECEx approved cable glands Class 1, Devision 1, Groups A, B, C, and D hazardous locations, temperatur code T5 As to fire, electrical shock and explosion hazards only UL certificated no. 2PD0. In accordance with UL 1203 standard. Only with UL approved cable glands Material Stainless steel AISI 316L (1.4404) Cable gland threads M20 1.5 or ½" NPT Ingress protection code IP68 (only with IP68 approved cable gland) Approved sensors G-Series Analog+Digital R-Series Analog R-Series Profibus R-Series CANBUS R-Series SSI R-Series DeviceNet Mounting flange M18 1.5 or ¾" - 16UNF - 3A Pressure rating 350 bar Peak pressure 530 bar Magnet type Ring magnets Level measurement Float on request Operating temperature 40 +75 ºC (1) 1/ T amb + is limited to max T amb + of used sensor 10ºC I 2 I

TECHNICAL DRAWING 147 198 19.5 Ø 85 Ø 60 Mounting Zone 51 Measuring Length 50 7500 25 Damping Zone *64 Ø 10 M5 M18 or 3/4" Zone 1 Zone 0 * Measuring length > 5000 mm = 66 mm M20 or 1/2" NPT Top mounted cable gland Ø 85 Ø 64 Side mounted cable gland Ø 85 Ø 64 86 Short top 158 / Long top 198 M20 or 1/2" NPT 25 25 86 Short top 147 / Long top 187 Ø 69 56 Ø 69 All dimensions in mm I 3 I

ACCESSORIES Position magnet Cable connectors Ø 32.8 Ø 23.8 Ø 13.5 7.9 Ø 4.3 Ø 17.3 ~ 60.5 Standard ring magnet Part no. 201 542-2 Female, straight, 6 pin Part no. 370 423 Female, straight, 6 pin with 10 m PUR cable Part no. MTS-A-370423-1000-530052 Material: PA ferrite GF20 Weight: ca. 14 g Operating temperature: 40 +100 C Surface pressure: max. 40 N/mm 2 Fastening torque for M4 screws: max. 1 Nm Housing: zinc nickel plated Termination: solder Contact insert: silver plated Cable clamp: PG9 Cable Ø: 6 8 mml Spanner tool Cable glands ATEX Spanner tool Part no. DIN 1018A AMF 80-90 mm M20 1.5 Part no. CG-816679 M20 1.5 Part no. CG-816609 1/2 NPT cable gland ATEX/CSA US, 180 C; Part no. 403 042 Type no. ADE1F-4 4 8.5 mm cable diameter, stainless steel Type no. ADE1F-6 8.5 16 mm cable diameter, stainless steel Type no. A3LF/16 1/2 NPT 4.0 8.4 mm cable diameter, nickel plated brass HPH rotation adapters For M18, M30 1.5 Part no. RTA-M18 For 3/4" UNF; 1 1/16 Part no. RTA-3/4" UNF-2 For 3/4" UNF; 1 ¼" Part no. 253 961 See document 551444 for further accessories. I 4 I

ORDER CODE H P H X X X X X X X X X X X X X X X a b c d a Design combination X X X X Choose a design combination from the chart below b Stroke length X X X X 50 7500 mm Example: Aproved short housing with M18 mounting threads and one side mounted cable gland with M20 threads and a measuring length of 650 mm: HPH-0900-0650-A c Version A Approved N Non approved d Type of approval for version 1000 A T E X ATEX U L / c U L UL/cUL DELIVERY Please order separately: Basic sensor and accessories DESIGN COMBINATION CHART Bottom Top Approval ATEX ATEX ATEX UL and cul ATEX 0100 0900 1000 ATEX 1000 UL/cUL 1300 0300 2100* * upon request I 5 I

Document Part Number: 551612 Revision A (EU.EN) 01/2015 LOCATIONS GERMANY MTS Sensor Technologie GmbH & Co. KG Auf dem Schüffel 9 58513 Lüdenscheid, Germany Tel. + 49 2351 9587-0 Fax + 49 2351 56491 info.de@mtssensors.com USA MTS Systems Corporation Sensors Division 3001 Sheldon Drive Cary, N.C. 27513, USA Tel. +1 919 677-0100 Fax +1 919 677-0200 info.us@mtssensors.com FRANCE MTS Systems SAS Zone EUROPARC Bâtiment EXA 16 16/18, rue Eugène Dupuis 94046 Creteil, France Tel. + 33 1 58 4390-28 Fax + 33 1 58 4390-03 info.fr@mtssensors.com ITALY MTS Systems Srl.Sensor Division Via Diaz,4 25050 Provaglio d Iseo (BS), Italy Tel. + 39 030 988 3819 Fax + 39 030 982 3359 info.it@mtssensors.com LEGAL NOTICES MTS and Temposonics are registered trademarks of MTS Systems Corporation. All other trademarks are the property of their respective owners. Printed in Germany. Copyright 2015 MTS Sensor Technologie GmbH & Co. KG. Alterations reserved. All rights reserved in all media. No license of any intellectual property rights is granted. The information is subject to change without notice and replaces all data sheets previously supplied. The availability of components on the market is subject to considerable fluctuation and to accelerated technical progress. Therefore we reserve the right to alter certain components of our products depending on their availability. In the event that product approbations or other circumstances related to your application do not allow a change in components, a continuous supply with unaltered components must be agreed by specific contract. JAPAN MTS Sensors Technology Corp. 737 Aihara-machi, Machida-shi, Tokyo 194-0211, Japan Tel. + 81 42 775-3838 Fax + 81 42 775-5512 info.jp@mtssensors.com CHINA MTS Sensors Room 504, Huajing Commercial Center, No. 188, North Qinzhou Road 200233 Shanghai, China Tel. +86 21 6485 5800 Fax +86 21 6495 6329 info.cn@mtssensors.com