RotorFlow Sensors Provide Visual Indication, Continuous Sensing and Accurate Switching

Similar documents
RotorFlow Sensors Provide Visual Indication, Continuous Sensing and Accurate Switching

RotorFlow Sensors Provide Visual Indication, Continuous Sensing and Accurate Switching

Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual

Flow Switches INTRODUCTION

Flow Switches INTRODUCTION

Shuttle Type Switches For Moderate to High Liquid Flow Rates

Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual

8000 Series Liquid Flow Meters

M Series. Feature rich flow meter and switch with in-line. flow

MODEL 106F TEFLON LIQUID FLOW SENSOR

PSF50 Paddle flow switch

100 Series Flow Switches Technical Reference Manual

8000 Series Liquid Flow Meter

G2 Industrial Grade Meters

200 Series Flow Meters

BASIC IN-LINE LIQUID FLOW RATE MONITORS. Data Sheet No. B-699. Select from aluminum, brass or stainless steel to meet system and liquid requirements.

Axial Turbine Flow Sensor Series Turbotron VTH 25 / VTI 25 / VTM 25

100 Series Flow Switches

DPT TARGET TYPE FLOWMETERS

MAX FLUID TEMPERATURE

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.

KEL DIFFERENTIAL PRESSURE FLOWMETERS

Flow Meters & Instruments. Insertion Paddle Wheel & Magnetic Flow Meters Flow & Anaytical Instruments. Technical Catalogue

Positive displacement flowmeter for continuous flow measurement

EZ-View. Flow Meters ISO CERTIFIED 9001

Pipe fittings MUST be installed by a certified welder only. +GF+ SIGNET will not assume liability of any kind for improper fitting installations.

Table of Contents. Automatic Section A B V. Coil Piping Packages A B P P. Water Source Heat Pump Hose Kits A B H K

500 SERIES METERING FLOW SWITCHES TECHNICAL REFERENCE MANUAL. Proteus Industries Inc. Proteus 5-Year Warranty

PRESSURE TRANSDUCERS. Specifications. Individual Specifications

EZ-View Flow Meters. With Flow-Alert TM Flow Switch REDUCE MAINTENANCE COSTS TEL

SSI Technologies Application Note PS-AN7 MediaGauge (Model MG-MD) Digital Pressure Gauge Product Overview

TECHNICAL SPECIFICATIONS. Measuring Accuracy ±2% of full scale. Repeatability ±0.5% of full scale

RCM - Direct Reading Flowmeters

Signet 2517 Brass Paddlewheel Flow Sensor * *

INSERTION flow sensor for continuous flow measurement

MX-SERIES OVAL GEAR FLOW METERS

Paddle-wheel flow controller for On/Off control

BI-DIRECTIONAL INSERTION FLOW TRANSDUCER

EZ-View Flow Meters. General Design Features OPERATING PRINCIPLE

NBK-M - Economical Level Indicator

MODEL U801 PTFE Flo-Controller for UHP Liquid Applications. uhp

A1 Commercial Grade Meters

KOBOLD DF-MA Flow Transmitter. User Instructions

INSERTION flowmeter with paddle wheel, ELEMENT design

IP80-Series FLOW SENSOR INSTRUCTIONS IP81 IP :2008 ISO CERTIFIED COMPANY IP80-SERIES FLOW SENSOR INSTRUCTIONS

IP800-Series FLOW SENSOR INSTRUCTIONS IP810 IP :2008 ISO CERTIFIED COMPANY IP80-SERIES FLOW SENSOR INSTRUCTIONS

M-61-F. Fixed Set Point Flow Switch. Description. Operating Principle. Application Examples.

display on the wall or in a panel away from the inline sensor SE30 for easy meter reading.

PISTON STYLE GAUGE. For Installation and Operation Manuals Please Visit: Mid-West Instrument

KOBOLD DF-WM Flow Monitor. User Instructions

Paddle-wheel flow controller for On/Off control

PISTON STYLE GAUGE. Mid-West Instrument

MINI-NBK ECONOMICAL LEVEL INDICATOR

Signet 2536 Rotor-X Paddlewheel Flow Sensors

RCM. Direct Reading Flowmeter. for Liquids or Gases

Ultra Compact UHP Liquid Flow Controllers

F-2000 MODEL RT INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

Flow Monitors Excess Flow Valves Flow Meters. ChemTec.com

Mid-West Instrument. Piston Type Differential Pressure Gauges Switches & Transmitters Model 122

Turbotron // VTH15, VTM15, VTP15, VTI15

Type 2712 (8630) Continuous TopControl System. General data Compatibility Materials of wetted parts Body Rotor Shaft Seal

SM-00. Features. Impeller Flowmeter for Small Volumes of Fluid. Description: Application:

Thermo Scientific Gilmont

Pipe fi ttings MUST be installed by a certifi ed welder only. Signet will not assume liability of any kind for improper fi tting installations.

IP800-Series FLOW SENSOR INSTRUCTIONS IP810 IP :2008 ISO CERTIFIED COMPANY IP800-SERIES FLOW SENSOR INSTRUCTIONS

DIGIFLO ELECTRONIC FLOWMETER

PRESSURE TRANSDUCERS. Specifications. Individual Specifications

Flowmeters & Monitors

DTK. OEM Pelton Wheel Flow Sensor

PKX MA/A. Characteristics

M-50/55 Series. Fixed setting flow switch with in-line flow

OMP POSITIVE DISPLACEMENT FLOWMETERS

Mid-West Instrument. Diaphragm Type Differential Pressure Gauge & Switch Model 130. Shown here with Range 0-5 H2O

Simple Set COMMERCIAL. Pressure Independent Control Valves 2 Way 1/2-2 02/16/18 COMMERCIAL

A1 SERIES COMMERCIAL GRADE METERS A1 SERIES COMMERCIAL GRADE METERS

Compact Electric Actuated Ball Valves PVC Body, Teflon/EPDM Seals 1/2 to 1 inch Pipe

Tracer VMA with AutoReg

2100 Turbine Flow Sensor

L-Series: LIQUID LEVEL FLOAT SWITCH. Single-Point, Vertically-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

J Series Filters HIGH PRESSURE FILTERS. J88 Mini In-Line (Replaceable Filter) J85 Tee-Type. J82 Mini In-Line. J83 In-Line

RP-CS 2-98 CERTA-SEAL LIQUID BAG FILTERS WITH THE MATCHED PERFORMANCE DESIGN. Products

A1 Commercial Grade Meters

Pressure Instrument Testing Equipment

MICROPUMP MAG-DRIVE GEAR PUMPS

Oscillating Pumps. Product Overview

System 350 P352AB Electronic Pressure Control Series

L007 LIQUID LEVEL FLOAT SWITCH. Side-Mounted Liquid Level Float Switch INSTALLATION AND OPERATIONS MANUAL

ProMinent Beta Solenoid Diaphragm Metering Pumps

OM SERIES OVAL GEAR METERS. OM SERIES Oval Gear Meters

SES. Stainless Single-Jet Meter Instructions PROUDLY MADE IN THE USA

700 Series FluidVision

Oscillating Pumps. 180 Hines Ave. Bellville, OH PH: FAX:

TX80-Series FLOW SENSOR INSTRUCTIONS TX81 TX :2008 ISO CERTIFIED COMPANY TX80-SERIES FLOW SENSOR INSTRUCTIONS

SRX R. Remediation Pumps. Simply Reliable

Installation Instructions

Operating Instruction for Plastic Vortex Flow Transmitter. Model: UV

High Performance Turbine Technology

M-200 Series. High flow, Adjustable flow switch with right-angle flow

TYPE MP OSCILLATING PISTON FLOWMETER

Installation Instructions

Transcription:

ROTORFLOW INTRODUCTION RotorFlow Sensors Provide Visual Indication, Continuous Sensing and Accurate Switching Bright, visual indication with choice of pulsed DC output, or adjustable 1 amp switched output Flow ranges from.1 GPM to 0.0 GPM Compact inline housings Available in high performance plastic, brass, or stainless steel housings RotorFlow Series Sensors are U.L. Recognized File No. E4518. Determined to provide you with the most versatile line of flow sensors available, we ve continued a non-stop refinement process for the entire RotorFlow Series. GEMS new generation of RotorFlow sensors, the RF-2500 Series, have been totally re-engineered with a one piece composite rotor, stronger unibody construction, ceramic shaft and better sealing. The results are greater durability with broader chemical, temperature and pressure capabilities. Today s RotorFlow Series is state-of-the-art and offers more options, better performance and durability than ever before...all at an affordable price geared for high volume, OEM applications. 7/1 Hex Hub Select the RotorFlow sensor that is right for your application by choosing one of our three distinct configurations. You ll find details on each of these configurations inside. RotorFlow Switch Types For specific flow setpoint switching, RotorFlow RFS type switches are one of the most reliable flow switches available. Setpoints are fully adjustable over the specified flow range. The dynamic operation of the rotor guards against jamming and false actuation. RotorFlow Output Types For flow rate monitoring or metering applications. RotorFlow RFO Type sensors provide a pulsed DC voltage output that is proportional to the rate of flow. The operating range of 4.5 to 24 VDC pulsed output is easily integrated into most digital logic units. RFA Type RotorFlow sensors provide a continuous 0-10 VDC analog output. RotorFlow Indicator Types For those who want simple visual confirmation of flow, RotorFlow RFI indicators provide the durable, low-cost answer. A bright, orange spinning rotor provides visual flow confirmation at a glance. High Resolution or High Visibility Rotors. Heavy Duty, Buna N O-Rings Now for line sizes up to 1! Ceramic Shaft Brass, Stainless Steel or High Performance, Polypropylene Bodies New wide-body senses flow up to 0 GPM. 3/4 and 1 line models. F-1

Flow Set Point Switching RFS Types Combines visual confirmation of flow with dynamic, electronic switch operation Easy, adjustable switch point calibration: a local LED signals when set point is reached RotorFlow Switches build an extra level of reliability and protection into your equipment. By principle of operation, the rotor cannot be deceived into indicating a positive flow situation when no flow actually exists. Once set to a desired actuation point, RotorFlow will switch to a no-flow condition should the rotor stop for any reason. Typical Applications Protect expensive electronic equipment from coolant flow failure on... Semiconductor Processing Equipment Lasers Medical Equipment X-Ray and Other High Power Tubes Robotic Welding Equipment File No. E4518 Wetted Materials Brass, 31 Stainless Steel or Polypropylene (Hydrolytically Stable, Glass Reinforced) Rotor Pin Ceramic Rotor PPS Composite, Black Lens Polysulfone O-Ring Viton (Alloy Bodies); Buna N (Polypropylene ) Low Flow Adaptor Glass Reinforced Polypropylene Operating Pressure, Maximum Brass or Stainless Steel 200 PSIG (13.8 bar) @ 70 F (21 C), 100 PSIG (.9 bar) Max. @ 2 F (100 C) 1 Polypropylene 100 PSIG (.9 bar) @ 70 F (21 C), 40 PSI (2.8 bar) Max. @ 180 F (82 C) Operating Temperature, Brass or Stainless Steel -20 F to 2 F (-29 C to 100 C) Polypropylene -20 F to 180 F (-29 C to 82 C) Electronics 150 F (5 C) Ambient Viscosity, Maximum 200 SSU Input Power 24 VDC or 115 VAC Relay Contact Ratings (SPDT) 1 Amp, 24 VDC Resistive; 0.3 Amp, 110 VAC Current Consumption No Load Load (Relay Energized) 24 VDC 20mA 35mA 115 VAC 45mA 95mA Repeatability 2% Maximum Deviation Set Point Accuracy (Factory Set) ± 5% Set Point Differential 15% Maximum Electrical Termination 20 AWG PVC-Jacketed, 24 Cable. Color Codes: Red = +VAC/VDC, Black = Ground, White = N.O. Contact, Brown = N.C. Contact, Green = Common Note: 1. Optional pulsed output available with RFS. Consult factory. Polypropylene Bodies 3.0 (77.7 mm) VDC.80 (20.3 mm) 2.38 (0.5 mm) 3.01 (7.4 mm).87 (22.1 mm) 2.32 (58.9 mm) 1.0 (2.9 mm) 2.50 (3.5 mm) 3.94 (100 mm).4 (1.3 mm) 2.37 (0.2 mm) 4.7 (0.9 mm) 2.37 (0.2 mm) VAC.80 (20.3 mm) 4.50 (114.3 mm) Brass and Stainless Steel Bodies -.25 and.50 Port VDC VAC 1/4 PORTS =.80 (20.3 mm) 1/2 PORTS =.87 (22.1 mm) 4.50 (114.3 mm) Brass and Stainless Steel Bodies -.75 and 1.00 Port VAC VDC 1.0 (2.9 mm) 2 (50.8 mm) F-2

RFS TYPE Switch Set Point Calibration With LED Signal (RFS Type) With the unit installed in the line and power supplied, complete the following steps to calibrate switch actuation point with proper flow rate. A small flat-blade screwdriver is the only tool required. 1. Adjust liquid flow in the line to the rate at which switch actuation is desired. 2. Insert screwdriver into opening on backside of housing and fit blade into the potentiometer adjustment screw inside. 3. If LED is not illuminated, slowly turn screwdriver counterclockwise and stop as soon as LED illuminates. 4. If LED is illuminated, turn screwdriver clockwise until LED light goes out. Then, slowly turn screwdriver counterclockwise and stop as soon as LED illuminates. 1/2" STRAIN RELIEF HOLE LED INDICATOR IS ILLUMINATED WHEN RELAY SWITCH IS CLOSED. AIDS FIELD CALIBRATION SET POINT ADJUSTMENT CABLE OUTPUT How To Order Specify Part Number based on desired body material, port size and input power rating. Port Size Flow Ranges GPM Input Part Material NPT Low Range* Standard Range Power Number Polypropylene.25 0.1 to 1.0 0.5 to 5.0.50 1.5 to.0 4.0 to 20.0.25 0.1 to 1.0 0.5 to 5.0 24 VDC 155425 115 VAC 15587 24 VDC 155485 115 VAC 15588 24 VDC 1525 115 VAC 152.50 1.5 to.0 4.0 to 20.0 24 VDC 1528 Brass 115 VAC 1529.75 5.0 to 30.0 1.00 8.0 to 0.0 9/1-18** 0.1 to 1.0 0.5 to 5.0 24 VDC 180395 115 VAC 18039 24 VDC 18188 115 VAC 18189 24 VDC 15073 115 VAC 15074 Stainless 24 VDC 15077 Steel.50 1.5 to.0 4.0 to 20.0 115 VAC 15078.75 5.0 to 30.0 1.00 8.0 to 0.0 * With use of Low Flow Adapter supplied. See Page F-8 for more information. ** Straight thread with O-ring seal. 24 VDC 18191 115 VAC 18192 24 VDC 18193 115 VAC 18194 Special Requirements: GEMS caters to OEM needs with special configurations for potable water and enhanced chemical capabilities. Consult factory for further details. High Resolution Black Rotor PPS composite. Each of the six rotor arms is magnetized. A PTFE loaded bushing ensures long life. Pressure Drop-Typical Standard Flow Range 9 1/4 Units Ports 1/2 Ports 3 0 0 1 2 3 4 5 10 15 20 25 Flow Rate GPM PSI PSI 9 Low Flow Range Units High Flow Units PSI 3 1/4 Ports 1/2 Ports 0 0.1.2.3.4.5..7.8.91.0 2 3 4 5 10 15 Flow Rate GPM 9 3 3/4 Ports 1.0 Ports For higher pressure/temperature ratings, stainless face plates are available. Consult factory. 0 0 10 20 30 40 50 0 70 80 90 100 110 Flow Rate GPM F-3

Ro HS Flow Rate Monitoring RFO Type 4.5 to 24 VDC Pulsed Output GEMS Sensors popularized the RotorFlow s paddlewheel design by combining high visibility rotors with solid-state electronics that are packaged into compact, panel mounting housings. They provide accurate flow rate output with integral visual confirmation...all with an unprecedented price/performance ratio. RFO Types feature a VDC pulsed output. Typical Applications Water Purification/Dispensing Systems Chemical Metering Equipment Lasers and Welders Water Injection Systems Semiconductor Processing Equipment Chillers and Heat Exchangers Wetted Materials Brass, 31 Stainless Steel or Polypropylene (Hydrolytically Stable, Glass Reinforced) Rotor Pin Ceramic Rotor PPS Composite, Black Lens Polysulfone 1 O-Ring Viton (Alloy Bodies); Buna N (Polypropylene ) Low Flow Adaptor Glass Reinforced Polypropylene Operating Pressure, Maximum Optional SS Face Plate 500 PSI Brass or Stainless Steel 200 PSIG (13.8 bar) @ 70 F (21 C), 100 PSI (.9 bar) Max. @ 2 F (100 C) 1 Polypropylene 100 PSIG (.9 bar) @ 70 F (21 C), 40 PSI (2.8 bar) Max. @ 180 F (82 C) Operating Temperature, Brass or Stainless Steel -20 F to 2 F (-29 C to 100 C) Polypropylene -20 F to 180 F (-29 C to 82 C) Electronics 150 F (5 C) Ambient Viscosity, Maximum 200 SSU Input Power 4.5 VDC to 24 VDC Output Signal 4.5 VDC to 24 VDC Pulse. (Sourcing) Pulse Rate Dependent on Flow Rate, Port Size and Range. Current Consumption 8 ma, No Load Current Source Output, Max. 70 ma Frequency Output Range 15 Hz (Low Flow) to 225 Hz (High Flow) Accuracy See Table Below Electrical Termination 22 AWG PVC-Jacketed, 24 Cable. Color Coded: Red = +VDC; Black = Ground; White = Signal Output Notes: 1. For higher pressure/temperature ratings, stainless face plates are available. Consult factory. Polypropylene Bodies 3.0 (77.7 mm) 3.01 (7.4 mm) File No. E4518.4 (1.3 mm) 1/4 PORTS = 80 (20.3 mm) 1/2 PORTS = 87 (22.1 mm) Ro HS.80 (20.3 mm) 2.38 (0.5 mm) Brass and Stainless Steel Bodies -.25 and.50 Ports Brass Bodies.75 and 1.00 NPT Ports 2.32 (58.9 mm) How To Order For standard configurations, specify Part Number based on desired body material and port size. F-4 Material Polypropylene Brass Stainless Steel Port Size NPT Low Range* (Accuracy) Flow Range GPM Standard Range (Accuracy) Part Number.25 0.1 to 1.0 (±7.0%) 0.5 to 5.0 (±7.0%) 155421.50 1.5 to.0 (±7.0%) 4.0 to 20.0 (±15.0%) 155481.25 0.1 to 1.0 (±7.0%) 0.5 to 5.0 (±7.0%) 1521.50 1.5 to.0 (±7.0%) 4.0 to 20.0 (±15.0%) 1522.75 5.0 to 30.0 (±15.0%) 19471 1.00 8.0 to 0.0 (±15.0%) 19472 9/1-18** 0.1 to 1.0 (±7.0%) 0.5 to 5.0 (±7.0%) 15071.50 1.5 to.0 (±7.0%) 4.0 to 20.0 (±15.0%) 15075.75 5.0 to 30.0 (±15.0%) 19473 1.00 8.0 to 0.0 (±15.0%) 19474 2.50 (3.5 mm) 3.94 (100 mm) High Resolution Black Rotor PPS composite. Each of the six rotor arms is magnetized. A PTFE loaded bushing ensures long life. 1.0 (2.9 mm) 2.95 (74.9 mm) Note: Improved accuracy can be achieved by calibrating the individual RFO unit. * With use of Low Flow Adapter supplied. See Page F-8 for more information. ** Straight thread with O-ring seal.

RFO TYPE Operating Principle FLOW OUT PARTIAL CUTAWAY HALL EFFECT SENSOR SENDS A VOLTAGE PULSE WITH EACH PASS OF MAGNETIC FIELD MAGNETIZED ROTOR FLOW IN 1. As liquid passes through the RotorFlow body, the magnetic rotor spins at a rate proportional to flow. This causes a series of magnetic fields (the rotor vanes) to excite the Hall Effect sensor, producing a series of voltage pulses. 2. The output pulses (RFO) are at the same voltage level as the input (4.5-24 VDC) with a frequency proportional to the flow rate. The output signal can be utilized by digital rate meters totalizers or other electronic controllers. RFA Type analog sensors condition the output signal to 0-10 VDC. 3. RotorFlow Indicators may be mounted with flow entering either port. Performance is optimized by positioning ports at the top of the unit, in a horizontal plane. Pressure Drop-Typical Standard Flow Range Units Low Flow Range Units High Flow Units PSI PSI PSI 9 1/4 Ports 1/2 Ports 3 0 0 1 2 3 4 5 10 15 20 25 Flow Rate GPM 9 3 1/4 Ports 1/2 Ports 0 0.1.2.3.4.5..7.8.91.0 2 3 4 5 10 15 Flow Rate GPM 9 3 3/4 Ports 1.0 Ports Frequency vs. Flow Rate-Typical Flow Rate (GPM).25.25 with Adapter* Output Frequency Hz RFO Model Based on Port Size.50.50 with Adapter*.75 1 0.10 13 0.25 41 0.50 15 90 0.75 137 1.0 34 18 1.5 54 17 2.0 73 25.9 2.5 90 34 3.0 110 43 3.5 8 4.0 148 34 0 4.5 18 5.0 185 44.8 7.7 24.0 55 94 7.0 5.9 111 8.0 7 9 22 9.0 87.5 147 10 99 15 1 30 11 110 185 2 204 13 135 14 147 15 158 93 43 1 170 17 183 18 195 19 207 20 220 8 0 25 13 74 30 19 91 35 107 40 3 45 137 50 153 55 170 0 185 *Low Flow Adapter 0 0 10 20 30 40 50 0 70 80 90 100 110 Flow Rate GPM Signal Output Output signal for RFO Types is an on/off pulse of the DC voltage supplied to the unit, it is compatible with all digital logic families. Input voltage range is 4.5 to 24 VDC. Frequency of the output pulse is proportional to the flow rate and ranges from approximately 15 Hz at low flow to 225 Hz at high flow. Example: +VDC Low Flow High Flow 0 0 TIME TIME Note: Consult factory for flow rate/frequency curves. +VDC F-5

Flow Rate Monitoring RFA Types 0 to 10 VDC Analog Output GEMS Sensors popularized the RotorFlow s paddlewheel design by combining high visibility rotors with solid-state electronics that are packaged into compact, panel mounting housings. They provide accurate flow rate output with integral visual confirmation...all with an unprecedented price/performance ratio. RFA Types feature a 0 to 10 VDC analog output which is proportional to flow rate. Wetted Materials Brass, 31 Stainless Steel or Polypropylene (Hydrolytically Stable, Glass Reinforced) Rotor Pin Ceramic Rotor PPS Composite, Black 1 Lens Polysulfone O-Ring Viton (Alloy Bodies); Buna N (Polypropylene ) Low Flow Adaptor Glass Reinforced Polypropylene Operating Pressure, Maximum Brass or Stainless Steel 200 PSIG (13.8 bar) @ 70 F (21 C), 100 PSIG (.9 bar) @ 2 F (100 C) 2 Polypropylene 100 PSIG (.9 bar) @ 70 F (21 C), 40 PSI (2.8 bar) Max. @ 180 F (82 C) Operating Temperature, Brass or Stainless Steel -20 F to 2 F (-29 C to 100 C) Polypropylene -20 F to 180 F (-29 C to 82 C) Electronics 150 F (5 C) Ambient Viscosity, Maximum 200 SSU Input Power 24 VDC, ±10% Output Signal 0-10 VDC Analog Signal @ 1mA, Max. Current Consumption 25 ma, Max. Current Source Output, Max. 10 ma Accuracy See Table Below Electrical Termination 22 AWG PVC-Jacketed, 24 Cable. Color Coded: Red = +VDC; Black = Ground; White = Signal Output Notes: 1. Standard on Stainless Steel bodies. 2. For higher pressure/temperature ratings stainless steel face plates are available. Consult factory. How To Order For standard configurations, specify Part Number based on desired body material and port size. Material Polypropylene Brass Stainless Steel Port Size NPT Low Range (Accuracy) Flow Ranges GPM Part Number Standard Range (Accuracy) Part Number.25 0.1 to 1.0 (±7.0%) 23020 0.5 to 5.0 (±7.0%) 230205.50 1.5 to.0 (±7.0%) 230207 4.0 to 20.0 (±15.0%) 230201.25 0.1 to 1.0 (±7.0%) 230209 0.5 to 5.0 (±7.0%) 230202.50 1.5 to.0 (±7.0%) 230210 4.0 to 20.0 (±15.0%) 230203.75 5.0 to 30.0 (±10.0%) 2302 1.00 8.0 to 0.0 (±15.0%) 230214 9/1-18 0.1 to 1.0 (±7.0%) 230211 0.5 to 5.0 (±7.0%) 230204.50 1.5 to.0 (±7.0%) 23021 4.0 to 20.0 (±15.0%) 230208.75 5.0 to 30.0 (±10.0%) 230213 1.00 8.0 to 0.0 (±15.0%) 230215 Typical Applications Water Purification/Dispensing Systems Chemical Metering Equipment Lasers and Welders Water Injection Systems Semiconductor Processing Equipment Chillers and Heat Exchangers Polypropylene Bodies 3.0 (77.7 mm) 3.01 (7.4 mm) 2.50 (3.5 mm) 3.94 (100 mm).4 (1.3 mm) 1/4 PORTS = 80 (20.3 mm) 1/2 PORTS = 87 (22.1 mm) 1.0 (2.9 mm) 2.95 (74.9 mm).80 (20.3 mm) 2.38 (0.5 mm) Brass and Stainless Steel Bodies -.25 and.50 Ports Brass Bodies.75 and 1.00 NPT Ports High Resolution Black Rotor PPS composite. Each of the six rotor arms is magnetized. A PTFE loaded bushing ensures long life. 2.32 (58.9 mm) F-

Ro HS RFA/RFI TYPES Visual Indicators RFI Types This is RotorFlow in its most basic form a bright orange rotor turning with fluid flow. Simple, direct and reliable. Flow rate is estimated, or simply confirmed, by viewing the speed of the turning rotor. Either port may be used for incoming flow, and bayonet mounting lens is easily removed for quick cleanout. RFI Type RotorFlow sensors are easy to see, easy to install and easy to afford. Typical Applications Visual flow confirmation on heat exchangers Plastic injection molding equipment Wetted Materials Rotor Pin Rotor Lens O-Ring Low Flow Adaptor Operating Pressure, Brass or Stainless Steel Polypropylene Operating Temperature, Brass or Stainless Steel Polypropylene Material Polypropylene Brass Stainless Steel Port Size NPT Low* Range Brass, 31 Stainless Steel or Polypropylene (Hydrolytically Stable, Glass Reinforced) Ceramic High Visibility Orange, Molded Nylon Polysulfone Viton (Brass ); Buna N (Polypropylene ) Glass Reinforced Polypropylene 100 PSIG (7 bar) @2 F (100 C) 200 PSIG (13.8 bar) Max. @ 70 F (21 C) 100 PSIG (.9 bar) at 70 F (21 C), 40 PSI (2.8 bar) Max. @ 180 F (82 C) -20 F to 2 F (-29 C to 100 C) -20 F to 180 F (-29 C to 82 C) Operating Principle 1. As liquid passes through the RotorFlow body, the rotor spins at a rate proportional to flow. 2. RotorFlow Indicators may be mounted with flow entering either port. At low flow rates, performance is optimized by positioning ports at the top of the unit, in a horizontal plane. How To Order Specify Part Number based on desired body material and port size. Flow Ranges GPM Standard Range Part Number.25 0.1 to 1.0 0.5 to 5.0 155420.50 1.5 to.0 4.0 to 20.0 155480.25 0.1 to 1.0 0.5 to 5.0 142541.50 1.5 to.0 4.0 to 20.0 142542.75 5.0 to 30.0 180392 1.00 8.0 to 0.0 18181 9/1-18** 0.1 to 1.0 0.5 to 5.0 17459.50 1.5 to.0 4.0 to 20.0 173138.75 5.0 to 30.0 18182 1.00 8.0 to 0.0 18183 * With use of Low Flow Adapter supplied. See Page F-8 for more information. ** Straight thread with O-ring seal. Polypropylene Bodies 3.0 (77.7 mm) 3.01 (7.4 mm) 2.50 (3.5 mm) 3.94 (100 mm).4 (1.3 mm).80 (20.3 mm).30 (7. mm) 1.37 (34.8 mm) 1/4 PORTS = 80 (20.3 mm) 1/2 PORTS = 87 (22.1 mm).30 (7. mm) 1.37 (34.8 mm) 1.0 (2.9 mm) 2 (50.8 mm) Ro HS Brass and Stainless Steel Bodies -.25 and.50 Ports Brass.75 and 1.00 Ports High Visibility Orange Rotor Constructed of Molded Nylon for good general purpose compatibility with a wide range of fluids. Offers high visibility. F-7

Easy Installation and Maintenance A proper installation will enhance RotorFlow sensor performance. Install using standard pipe fitting tools; horizontal fluid lines are recommended. For further installation and maintenance recommendations, refer to one of the following instruction bulletins: RFO Types Part Number 157258; RFI Types Part Number 157259; RFS Types Part Number 15721. Since their function is to monitor dynamic fluid flow, naturally the rotor will react to turbulence, pulsation, entrained air, and other flow anomalies induced in the flow stream by other process hardware. For optimum performance, install RotorFlow units where nominal flow conditions exist with ports located at the top. Incoming flow may be placed to either port; a minimum of 8 inches (20 cm) of straight pipe on the inlet side is required. When operating in the low flow range, the supplied Low Flow Adapter must be installed in the incoming port. 8 MIN (20 CM) Panel Mounting Plastic Bodies. Two (2) mounting ears are provided at the body center line to receive #8 self-tapping screws to accommodate panel mounting of the plastic RotorFlow units. Note: ANSI T type 23 self-tapping screws are recommended. They may be replaced with standard machine screws if re-installation should be required. Brass and Stainless Steel Bodies. Two (2) mounting holes are provided on the body centerline, as shown below. #8-32UNC-2B screws are required for mounting. Incoming Flow Low Flow Adapter Except for straight-thread versions, RotorFlow sensors connect to piping via NPT mating thread forms. The use of an appropriate thread sealant is necessary to assure a leak-tight connection. Permatex No More Leaks or 2 wraps of Teflon tape are the only sealants recommended for GEMS flow sensors. Straight-thread versions require an O-ring for sealing. 150 micron filtration is recommended. However, should foreign particles enter the RotorFlow sensor, accumulation is easily cleared by removing the lens from the body. The lens is removed by turning its 7/1 hex center hub 45 counter-clockwise with a standard socket wrench. To reinstall the lens, simply reverse the process. Pressure must be relieved from the system prior to sensor clean-out. O-rings should be lubricated prior to re-assembly. Low Flow Applications A low flow adapter is supplied with all Rotorflow units. It is used to produce accurate response at low flow rates. Install the adapter, as shown above, in the port selected for incoming flow. RotorFlow Sensor Special Capabilities are Yours for the Asking. Gems caters to OEM needs with special configurations that go beyond the standards in this catalog. We can provide RotorFlow sensors with enhanced chemical compatibility, higher temperature and pressure capabilities, and alternate electrical terminations. Other Capabilities Available to OEMs: Electrical outputs: Combined switch and frequency; transistor switching; 0-10 VDC analog. Custom face plate (cast stainless steel face plate pictured) Buna N, Viton, EPDM, Silicon or Other Material O-Rings Polysulfone, Stainless Steel or Polypropylene Lens RotorFlow Maintenance Kits Rebuild your RotorFlow Sensors and Switches in less than 5 minutes with one of these kits. Includes: Ceramic Rotor Pin -Pole Magnetic Rotor with PPS/PTFE Bushing Buna N or Viton O-Ring Polysulfone Lens Rotorflow Type Line Size 1/4 & 1/2 Material O-Ring Material in Kit Part Numbers RFA/RFO/ RFS RFI Plastic Buna-N 155870 155872 Brass/SS Viton 1734 127 3/4 & 1 Brass/SS Viton 15718 157187 PPS Composite with Teflon or Nylon Loaded Bushing Panel Mounting Tabs Long-Life Ceramic Rotor Pin RF-2500 Sensors Hydrolytically Stable Polypropylene, Stainless Steel or Brass We are committed to providing our customers with the product that best meets the requirements of their applications. Please call us and tell us what you need, and ask us about Swagelok tube fittings, faceplate options, and 9/1 and 3/4 straight-thread versions. Call 800-378-100 F-8

Ro HS TURBOFLOW FT-110 Series TurboFlow Economical Flow-Rate Sensors Low Cost Plus High Accuracy ±3% of Reading Measures Low Liquid Flow Rates of.1 to 8 GPM Lightweight Plastic Design Enables Mounting in any Position Gems Hall Effect turbine flow rate sensor is ideal for OEM applications involving low flow liquid monitoring. The low cost coupled with 1/2% repeatability makes it an ideal candidate for replacing dispensing timer systems. Unlike existing timing systems, turbine technology is not influenced by changes in system pressure caused by aging filters. The sensor s standard power and output specifications make it easy to retrofit to existing controllers. Ro HS Wetted Materials Nylon Turbine Bearings Operating Pressure Burst Pressure Operating Temperature Viscosity Filter Input Power Output (Hz) Accuracy Repeatability Flow Range Pulses per Frequency 3/8 NPT Part Number GPM Liters/m Gallon Liter Output Spade Cable.13-1.3.5-5.0 2200 900 58-575 Hz 173931 173931-C.13-2.0.5-7.5 17400 400 38-575 Hz 173933 173933-C.2-2.7 1-10 500 3300 55-550 Hz 173932 173932-C.2-4.0 1-15 8300 2200 37-550 Hz 173934 173934-C.2-. 1-25 3800 1000 1.7-41 Hz 173935 173935-C.53-9.2 2-35 250 700 23-408 Hz 23425 23425-C Description Nylon Composite PTFE/15% Graphite 200 PSIG 2500 PSIG -4 F to 2 F (-20 C to 100 C) 32 to 81 SSU (.8 to 1 Centistokes) <50 Microns 5 to 24 VDC @ 8mA NPN Sinking Open Collector @ 20mA Maximum Leakage Current 10µA (Pull-Up Resistor Required) ±3% of Reading 0.5% of Full Scale Electrical Connection Spade Terminals.110 /.248 x.031 (2.8/.3 x.8 mm) or 3 ft. cable Inlet/Outlet Ports How To Order Standard Models Specify Part Number based on flow range. FT-110 Accessories Consult factory for special customized OEM versions. 3/8 NPT Male (3/8 G Male also available) Part Number Mating connector w/3 feet, 3 conductor, PVC pigtail cable 173941 Mating connector w/10 feet, 3 conductor, PVC pigtail cable 173942.8 (22.0 mm).118 (30.0 mm) PRESSURE DROP (PSID).197 (5.0 mm) Wiring Cable Wire Code: 18 1 14 10 8 4 2 0.9 (17.0 mm) FLOW.524 (13.3 mm) 2.15 (55.0 mm).110 (2.8 mm) White.248 (.3 mm) Red 3/8 MNPT OR 3/8 G White Black Red = 5 to 24 VDC Black = Ground Brown = Signal Output Pressure Drop Typical.70 (17 mm) (-).393 (10.0 mm).197 (5.0 mm).315 (8.0 mm) (17 mm) OUTPUT O Vdc 2k-20k ohms CUSTOMER SUPPLIED (+) 5-24Vdc 0.25.50 1 2 2.5 3 4 5 7 8 FLOW RATE - GPM Tests conducted with water flow at 8 F (20 C). A) Part # 173931 173932 173933 A B B) Part # 173934 173935 F-9

Ro HS FT-210 Series TurboFlow Low Flow Turbine Sensor Low Flow Rates.1 to 2.5 LPM and High Accuracy ±3% of Reading Lightweight Turbine Ensures Fast Startup Mounts In Any Orientation Gems FT-210 features proven turbine technology in a small package for low flow applications. The turbine technology provides a highly repeatable sensor ideally suited for measurement of either volume dispensing and/or flow rate applications. The small turbine reacts quickly to on/off dispensing applications. Each sensor is 100% tested, ensuring years of service life. Wetted Materials Nylon (Grilamid TR55) Turbine Nylon Composite Bearings PTFE/15% Graphite Operating Pressure 350 PSI (24 bar) Burst Pressure 1400 PSI (97 bar) Flow Range.02-.5 gallons/minute 0.1-2.5 liters/minute 3.4-84.5 ounces/minute Pulses 83,200 per gallon 22,000 per liter 50 per ounce Frequency Output 3.-917 Hz Operating Temperature -4 F to 2 F (-20 C to 100 C) Viscosity 32 to 70 SSU (.8 to 1 Centistokes) Filter <50 Microns Input Power 5 to 24 VDC Output (Hz) NPN Sinking Open Collector @ 20mA Maximum Leakage Current 10μA (3K-30K Pull up resistor required) Accuracy ±3% of Reading Repeatability 0.5% of Full Scale Electrical Connection 9.4mm Spacing 3-pole DIN Connector (1 high) Inlet/Outlet Ports 1/4 NPT (1/4 G Male also available) How To Order Specify a Part Number for the Port Connection AND a Part Number for the DIN Electrical Connection. Two Part Numbers are required for a complete part assembly. FT-210 Sensor Material Port Size Part Number Nylon 1/4 NPT 245 1/4 G 240.11 (2.8 mm) Wiring.43 (11.0 mm) 1.77 (45.0 mm) Pin Code: 1 = Output 2 = Supply 4 = Common.83 (21.2 mm) 1.11 (28.2 mm) 1/4 NPT OR 1/4 G (+) (-) Ro HS.7 (17.0 mm) 3k-30k Ohms CUSTOMER SUPPLIED 5-24Vdc O Vdc For Mating DIN Connector P/N 2404 Function DIN Termination V+ 1 Output 2 Pressure Drop Typical OUTPUT Electrical Connection Description Part Number 1 meter DIN PVC Cable Assembly with 10K pull-up resistor 218572 Mating DIN Connector 2404 P MBAR 400 350 300 250 200 150 100 50 GPM 0.13 0.2 0.40 0.53 0. 0 0 0.5 1 1.5 2 2.5 3 FLOW RATE - L/MIN 5.0 4.4 3. 2.9 2.2 1.5 0.7 PSI F-10

TURBOFLOW FT-330 Series NSF Approved Materials High Accuracy: ±2% of reading High repeatability: ±0.5% of reading Overmolded electronics with integral cable strain reinforcement Measures flow rates from.2 to 4 GPM Lightweight plastic design for multiple mounting positions Ro HS The FT-330 is a highly accurate and repeatable, Hall Effect turbine flow sensor designed for low flow OEM applications. This low cost, NSF Std. 1 listed flow sensor is ideal for water or beverage dispensing applications or any application with water based liquids. The 31SS shaft coupled with Delrin bearings allows for accurate measurements during quick dispensing cycles. The sensor s standard power and output specifications make it easy to retrofit existing controllers. Materials Turbine Axle Bearings Inlet/Outlet Ports Pressure Operating Burst Operating Temperature Viscosity Recommended Filtration Input Power Output (Hz) Accuracy Repeatability Electrical Connection Approvals Wiring FT-330 SENSOR How To Order GPM Flow Range LPM Glass Reinforced PPO (Noryl) PA Composite (Nylon) 31 Stainless Steel Delrin (Polyoxymethylyne, POM) 3/8 NPT Male 200 PSIG 1000 PSIG -4 F to 17 F (-20 C to 80 C) 32 to 81 SSU (1.8 to 1 Centistokes) < 50 Microns 5 to 24 VDC @ 8mA NPN Sinking Open Collector @ 25mA Maximum leakage current 10µA (5k to 30k Pull-Up Resistor Required) ±2% of reading ±0.5% of reading 3 ft PVC cable #22 AWG NSF Std. 1 listed, RoHS Frquency Out WHITE OUTPUT BLACK 0 VDC 10k Ohms CUSTOMER SUPPLIED RED 5-24 VDC Specify Part Number based on flow rate measuring capability. Pulses Per Gallon Pulses Per Liter Part Number 0.2 to 2 0.8 to 7. 34 to 343 Hz 10,313 2724 22000 0.4 to 4 1.5 to 15 29 to 343 Hz 4,994 1319 22100 K-factor Chart* - Part Number 22000 K FACTOR (pulses per gallon) PRESSURE DROP (PSI) 000 10000 8000 000 4000 2000 18 1 14 10 8 4 2 2.23 0 0 0.2 0.4 0. 0.8 1 1.2 1.4 1. FLOW RATE (GPM) * Consult factory for P/N 22100 K-factor chart Pressure Drop Typical 22000 NSF approved 0.70 CABLE 34-3" EXTENDED 3 COND. PVC 3/8 NPT 22100 0.89 REF. 0 0 1 2 3 4 5 Q (GPM) F-11

NOTES F-