Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

Similar documents
Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

Temposonics. M-Series Analog Redundant. Absolute, Non-Contact Positions Sensors. Temposonics MT Measuring length mm

Temposonics. M-Series Analogue / SIL2* Absolute, Non-Contact Position Sensors. Temposonics MH Measuring Length mm

Temposonics. M-Series PWM. Absolute, Non-Contact Position Sensors. Temposonics MH Measuring Length mm. Document Number Revision B

Temposonics. M-Series Analog. Absolute, Non-Contact Position Sensors. Temposonics MH Measuring length mm. Compact Sensor for Mobile Hydraulics

Temposonics. Absolute, Non-Contact Position Sensors. MH Series. Temposonics MB Analog. Technical Data / Description

Temposonics. MH-Series Analog Redundant. Absolute, Non-Contact Positions Sensors. Temposonics MT Measuring length mm

Temposonics. Absolute, Non-Contact Position Sensors. MH Series. Temposonics MH Analog /Digital. Technical Data / Description

R-Series Rod Model RS. Data Sheet. Model RS Rod-style sensor with IP68/IP69K Super Shield Housing. Interrogation Return wire.

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors

Temposonics. M-Series Analog. Magnetostrictive Position Sensors. Temposonics MH Measuring length mm SENSORS

Temposonics. Absolute, Non-Contact Position Sensors. MH Series. Temposonics MH 200. Technical Data / Description. Compact sensor for mobile hydraulics

ANALOG. PARAMETER SPECIFICATION Measured Variable: Displacement, Velocity (magnitude only) 16 bit or mm, whichever is greater

Temposonics. Magnetostrictive, Absolute, Non-contact Linear-Position Sensors. R-Series Models RP and RH Ethernet POWERLINK.

Temposonics. Magnetostrictive, Absolute, Non-contact Linear-Position Sensors. R-Series Models RP and RH DeviceNet Output.

Temposonics. Magnetostrictive Linear Position Sensors. MH-Series MH5 Analog Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. MHRM Analog Data Sheet. For embedded or externally threaded installation

Temposonics. G-Series Analog Redundant. Magnetostrictive Position Sensors. Redundancy for enhanced safety

Temposonics. Magnetostrictive Linear-Position Sensors. R-Series Model RP and RH Sensors Synchronous Serial Interface (SSI) Output D

SSI. Synchronous Serial Interface

CANBUS G. Up to mm ( in.) < ± 0.01% of full stroke or ± 0.04 mm ( in.), whichever is greater*

Temposonics. E-Series Analog + Start / Stop. Magnetostrictive Position Sensors. Temposonics EP Measuring range mm / mm SENSORS

Temposonics. R-Series DeviceNet. Magnetostrictive Position Sensors. Intelligent Design. Temposonics RP and RH Measuring length mm SENSORS

Temposonics. Magnetostrictive Linear Position Sensors. TH Analog Data Sheet

Temposonics. G-Series Analog or Start/Stop. Absolute, Non-Contact Position Sensors. Temposonics GP and GH Stroke length mm depends on output

Temposonics. Magnetostrictive Linear Position Sensors. TH CANbus Data Sheet

Temposonics ATEX. Magnetostrictive Linear Position Sensors. DATA SHEET High Pressure Housing (HPH) The Measurable Difference

L E V E L P L U S M - S E R I E S ANALOG

Temposonics. Magnetostrictive Linear Position Sensors. DATA SHEET GBS Analog

Temposonics. Magnetostrictive Linear Position Sensors. TH Analog SIL 2 capable Data Sheet

Temposonics. Magnetostrictive Linear Position Sensors. MH-Series Flexible MH Installation Manual

Part No Rev. E

958A Compact. Series 958 Compact Housing LDT. Housing ABSOLUTE PROCESS CONTROL KNOW WHERE YOU ARE... REGARDLESS

Temposonics Magnetostrictive Linear-Position Sensors

958A Compact Housing Linear Displacement Transducer

Level Plus. Magnetostrictive Liquid Level Transmitters with Temposonics Technology. LP-Series SE Replacement Installation Manual

High temperature pressure transmitters for heavy-duty applications MBS 2200 and MBS 2250

Temposonics Magnetostrictive Linear Position Sensors. Temposonics GB-Series Brief Instructions

Data Sheet for Linear Sensors

Pressure transmitters for heavy duty applications MBS 3200 and 3250

Temposonics. R-Series Analog. Absolute, Non-Contact Position Sensors. Temposonics RP and RH Stroke length mm

PRODUCT SELECTOR GUIDE

Pressure transmitters for heavy-duty applications MBS 2000 and MBS 2050

Pressure transmitter for industrial applications Type MBS 4500

958A Embedded Linear Displacement Transducer. THEINSIDER the most trusted information comes from INSIDE

Pressure transmitter for general industrial purposes MBS 3000 and MBS 3050

Pressure transmitter for marine applications MBS 3100 and MBS 3150

Pressure transmitters for industrial applications Type MBS 4510

Pressure transmitter for general industrial purposes Type MBS 3000 and MBS 3050

0 to 100 up to 0 to PSI (gage) Packard Electric Metri-Pack 150 Series, M12-4 Pole* 1/4-18 NPT ma, VDC, 0-5 VDC, 0-10 VDC

PRODUCT SELECTOR GUIDE

Pressure transmitter for general purpose Type MBS 1700 and MBS 1750

Temposonics Magnetostrictive Linear Position Sensors. Temposonics E-Series Brief Instructions

Pressure transmitter for industrial applications Type MBS 4510

Temposonics. Temposonics R-Series. Instruction Manual. EtherCAT Interface. Absolute, Non-Contact Position Sensors. Rod model Temposonics-RH

Technical Data Measuring principle Thin-film-on-steel Media temperature -40 C C

Data Sheet P1A Pressure Sensor

Pressure transmitter for marine applications Type MBS 5100 and MBS 5150

Profibus-DP Output. Profibus-DP output: Standard Profibus-DP signal. Profibus Output

Pressure transmitter for marine applications MBS 33M

Solid State Electronic Pressure Switch with Integral LED Display Model PSD-10

OEM Pressure Transmitters for heavy-duty applications Type MBS 1200 and MBS 1250

DA 15 N 06 BLDC 250 DA 15 N 12 BLDC 250

OEM Pressure transmitter for industrial applications Type MBS Technical brochure

Pressure transmitters for heavy duty applications Type MBS 3250

Temposonics. Magnetostrictive Linear Position Sensors. GB-Series Analog Operation Manual

Intrinsically safe presure transmitters for hazardous environments Type MBS 4201, MBS 4251, MBS 4701 and MBS Technical brochure

Data Sheet P265 Stainless Steel Pressure Transducer

Pressure transmitters for heavy duty applications MBS 8200 and MBS 8250

TURCK Inc Campus Drive Minneapolis, MN Application Support: Fax: (763) M2

MS-13SR series Spring Return Linear Potentiometers

MBS 1200 and MBS 1250

Electronic Pressure Switches

P500 Pressure Sensor. Description. Features. Applications MAIN FEATURES

Electronic Pressure Switches

OBSOLETE. Data Sheet P1E Oxygen Service Pressure Sensor. Main Features. Typical Applications. Attributes. Description

ACTUATORS POSITION SENSOR

INDUCTIVE SENSORS FOR UTILITY VEHICLES. Sense it! Connect it! Bus it! Solve it!

Temposonics Absolute, Non-Contact Position Sensors

GIB TECHNICAL DATA MECHANICAL DIMENSIONS SINGLE/DUAL AXIS ENTRY LEVEL TILT SENSOR (XY/Z) ENTRY LEVEL tilt sensor with MEMS technology.

Data Sheet P4055 Pressure Transducer

Temposonics. R-Serie Catalog. 0.5 μm. Absolute, Non-Contact Position Sensors. The Measurable Difference

P255 Stainless Steel Pressure Transducer

Temposonics. R-Series Analog. Absolute, Non-Contact Position Sensors. Temposonics RP and RH Measuring length mm

Linear-Transducer LMP48 - A

P1A Pressure Sensor. Description. Features. Applications MAIN FEATURES

Pressure Transmitter for wind turbine applications MBS 8200 and MBS 8250

DA 15 T 06 BLDC 1000 DA 15 T 12 BLDC 1000

Data Sheet P255 Stainless Steel Pressure Transducer

JUMO MIDAS S05 Pressure transmitter Type

Powerful, durable and quick to mount. Magnetic and cylinder sensors from ifm electronic.

SRS SEALED ROTARY SENSORS

LMK 387. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO

HX-P420 SERIES 4 to 20 ma OUTPUT

M5200 Industrial Pressure Transducer

Electronic Pressure Switches

Temposonics Absolute, Non-Contact Position Sensors

SATRON VDt Differential Pressure Transmitter

Weatherproof Tubular Slip Ring Assembly

Transcription:

Temposonics Magnetostrictive, Absolute, Non-contact Linear-Position Sensors MH-Series Mobile Hydraulic in-cylinder Sensor Model MH Analog Output Data Sheet SENSORS Document Part Number 550824 Revision K MH-Series Model MH Sensor Cylinder Application Example FEATURES Linear, Absolute Measurement in Hydraulic Cylinders Non-Contact Sensing Technology Superior Accuracy, < ± 0.04% F.S. Hysteresis < ± 0.1 mm Repeatability, < ± 0.005% F.S. Compact Design for Embedded Cylinder Applications Direct Analog Output: 0.25 to 4.75 Vdc, 4 to 20 ma Stroke length: 50 mm (2 in.) to 2500 mm (98 in.) Voltage input: 12/24 Vdc Shock Rating: 100 g (single hit) / IEC 68-2-27 Vibration Rating 25 g / 10-2000 Hz/IEC 68-2-6 200 V/m EMI Immunity Product overview The MH-Series Model MH sensor is designed with the mobile world in mind. The Model MH sensor is validated in the field by customers worldwide. Performance is second-to-none with high EMI resistance of 200 V/m. Ruggedness is designed in ; 100 g shock and 25 g vibration rating. The model MH analog sensor can be fully sealed and embedded in a cylinder to ensure a long operating life. Direct connection to the Temposonics M12x1 connector system and other proven mobile connectors are available. BENEFITS Rugged Mobile Sensor Direct Analog Output (Fully reversible) APPLICATIONS Continuous Operation In Harsh Mobile Conditions High Pressure Conditions For Welded and Tie-rod Cylinder Applications TYPICAL INDUSTRIES Construction Agriculture Off-highway Machinery All specifications are subject to change. Contact MTS for specifications and engineering drawings that are critical to your application. Drawings contained in this document are for reference only. Go to http://www.mtssensors.com for the latest support documentation and related media.

Product Specifications and Output Options Product specifications Parameters OUTPUT Measured variable: Specifications Linear Position measurement Resolution: Range: Resolution: Outputs: Stroke length: Linearity uncorrected: Repeatability: Hysteresis: Outputs: Operating voltage: Power consumption: ELECTRONICS Electrical isolation: 50 to 500 mm 750 mm 1,000 mm 1.250 mm 1,750 mm Voltage: 0.25 to 4.75 Vdc 0.5 to 4.5 Vdc with failure output signal Load resistance: > 10kΩ ± 0.10 mm ± 0.18 mm ± 0.24 mm ± 0.30 mm ± 0.42 mm Current: 4 to 20 ma Load resistance: 250Ω at 12/24 Vdc power supply 50 mm to 2500 mm (2 in. to 98 in.) Measured in 5 mm (0.20 in.) increments < ± 0.04% full stroke (minimum ± 0.100 mm 0.003 in.) < ± 0.08% full stroke (for short damping zone) < ± 0.005% of full stroke ± 0.1 mm (0.003 in.) Direct Analog: Voltage: 0.25 to 4.75 Vdc, 0.5 to 4.5 Vdc 4.75 to 0.25 Vdc, 4.5 to 0.5 Vdc Current: 4 to 20 ma, 20 to 4 ma 12/24 Vdc (8-32 Vdc) 1 W Polarity protection: Up to -36 Vdc Overvoltage protection: Up to 36 Vdc 500 Vdc (DC ground to machine ground) Parameters ENVIRONMENTAL Operating conditions: EMI test: Specifications Operating: -40 C (-40 F) to +105 C (221 F) Storage: -30 C (-22 F) to +105 C (221 F) 90% relative humidity, no condensation 200 V/m: ISO 11452-5 ISO 14982 - Agriculture and forest machinery Shock rating: 100 g (single hit)/iec standard 68-2-27 (survivability) Vibration rating: 25 g / 10 to 2000 Hz /IEC standard 68-2-6 WIRING Connection type: One 4-wire with the M12x1 connector and flange (provides IP69K environmental protection when installed in a cylinder). ROD STYLE SENSOR (Model MH) material: Sensor rod: Stainless steel 1.4306 / AISI 304L Housing: Stainless steel 1.4305 / AISI 303 Mechanical assembly: Flange housing 48 mm (1.89 in.) dia., O-ring 40.87 x 3.53 mm NBR 80, backup ring 42.6 x 48 x 1.4 PTFE Sealing: IP67 (IP69k when installed inside a cylinder with M12 x 1 in. connection type) Pressure rating: Sensor rod, 10 mm (0.39 in.): Operating, 350 bar (5076 psi) Peak, 530 bar (7687 psi) Sensor rod, 7 mm (0.27 in.): Operating, 300 bar (4350 psi) Peak, 400 bar (5800 psi) Magnet type: Ring magnet, Output range is factory programmable through entire stroke and is fully reversible. Output options The MH-Series Model MH position analog sensor provides direct analog outputs: Voltage; 0.25 to 4.75 Vdc, 0.5 to 4.50 Vdc (reverse acting: 4.75 to 0.25 Vdc, 4.5 to 0.5 Vdc) Current; 4 to 20 ma (reverse acting: 20 to 4 ma) Product Data Sheet, Document Part No.: 550824, Revision K 1/12, 5/12, 8/12, 12/12, 6/13 (US) 2

Model MH sensor dimension references MH-Series Model MH Analog Sensor Dimension and Magnet References Model MH, rod-style Sensor Drawing is for reference only, contact applications engineering for tolerance specific information. Figure 1. MH-Series Model MH rod-style sensor dimension reference Standard magnet selections (Model MH) SELECTION OF POSITION MAGNETS (MAGNET AND MAGNET SPACER MUST BE ORDERED SEPARATELY) A choice of three magnets are available with the Model MH rod-style sensor. Magnets must be ordered separately with Model MH position sensors. The standard ring magnet (part number 201542-2) is suitable for most applications. STANDARD RING MAGNET Part number 201542-2 MAGNET SPACER Part number 400633 (used with magnet part no.: 201542-2) RING MAGNET Part number 400533 RING MAGNET Part number 401032 Material: Ferrite PA I.D.: 13.5 mm (0.53 in.) O.D.: 33 mm (1.3 in.) Thickness: 8 mm (0.3 in.) Operating temperature: - 40 C (-40 F) to - 105 C to (221 F) Material: Non-ferrous, used with ring magnet (part no.: 201542-2) I.D.: 14 mm (0.56 in.) O.D.: 32 mm (1.25 in.) Thickness: 3.2 mm (0.125 in.) Material: Ferrite PA I.D.: 13.5 mm (0.53 in.) O.D.: 25.4 mm (1 in.) Thickness: 8 mm (0.3 in.) Operating temperature: - 40 C (-40 F) to - 105 C to (221 F) Material: Ferrite PA I.D.: 13.5 mm (0.53 in.) O.D.: 17 mm (0.68 in.) Thickness: 8 mm (0.31 in.) Operating temperature: - 40 C (-40 F) to - 105 C to (221 F) 3 Product Data Sheet, Document Part No.: 550824, Revision K 1/12, 5/12, 8/12, 12/12, 6/13 (US)

Model MH Rod-Style Sensor Installation Model MH sensor installation references The robust Temposonics Model MH sensor s new stainless-steel position sensor is designed for direct stroke measurement in mobile hydraulic cylinders. The Temposonics Model MH sensor can be installed from the head side or the rod side of the cylinder depending on the cylinder design. Installation Notes: 1. Use a non-ferrous circlip to fix the magnet. 2. The piston rod bore is dependent on hydraulic pressure and piston velocity. Minimum drilling for a (10 mm rod) should be 13.5 mm. 3. There should be no less than 3 mm clearance between the end of the sensor rod and the bottom of the rod bore at full retraction. Model MH, rod-style sensor mechanical installation Drawing is for reference only, contact applications engineering for tolerance specific information. Figure 2. MH-Series Model MH rod-style sensor mechanical installation example Model MH, rod-style sensor installation Drawings are for reference only, contact applications engineering for tolerance specific information. Installation methods are possible in magnetic and non-magnetic applications (shown in Figures 3 and 4) and are entirely dependent on the cylinder design. While the most common method of installation is from the rod side of the cylinder, installation from the head side of the cylinder is also possible. In both installation methods, the sensor seals the cylinder by using an O-Ring and backup ring which is installed on the sensor housing. Magnetic material installation reference Set screw detail Figure 3. Model MH installation in magnetic material using a non-ferrous magnet spacer. Non-magnetic material installation reference Figure 4. Model MH installation in non-magnetic material shown without magnet spacer Product Data Sheet, Document Part No.: 550824, Revision K 1/12, 5/12, 8/12, 12/12, 6/13 (US) 4

Connections and wiring Model MH Rod-Style Sensor Connections, Wiring and Mounting CONNECTION TYPE The Temposonics M12 connector system (shown in Figures 7, 8, 9 and 10 ), meets the most stringent protection requirements important for the difficult environmental conditions of mobile hydraulics applications. Protection type IP69K makes the robust metal housing not only completely dust and waterproof, even the harshest cleaning measures cannot damage the sensor. Model MH, rod-style sensor connector and pin assignments Drawings are for reference only, contact applications engineering for tolerance specific information. Pin Assignment (e.g. N06G) (1) Power Supply +12/24 Vdc (2) N.C. (3) 0 Vdc (4) Output: ma, Vdc 4 3 1 2 Pin Assignment (e.g. N06E) (1) N.C. (2) Power Supply +12/24 Vdc (3) 0 Vdc (4) Output: ma, Vdc Pin Assignment (e.g. N06H) 0 Vdc 0 Vdc (1) Power Supply +12/24 Vdc (2) Output: ma, Vdc (3) 0 Vdc (4) N.C. 0 Vdc Figure 5. Model MH sensor connection dimensions Figure 6. M12 x 1 connector system pin assignments MOUNTING THE CONNECTOR SYSTEM TO THE CYLINDER Figure 7. The MH sensor is delivered by MTS together with the new connector system: The connector insert carrier is already connected to the sensor electronics, i.e. no soldering, any color or connection mistake. Figure 8. The connector insert is taken out of the cylinder through a bore hole. The flange housing can be snapped into position easily from outside. Figure 9. Four standard screws must be tightened to mount the connector system on the cylinder. Figure 10. With a corresponding mating molded plug the connector system fulfills a ingress rating of IP69K. 5 Product Data Sheet, Document Part No.: 550824, Revision K 1/12, 5/12, 8/12, 12/12, 6/13 (US)

Model MH Rod-Style Sensor Ordering Information MH-Series Model MH ordering information Use the table below to configure your sensor part number. M H M 3 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 SENSOR MODEL = M H 1-2 MH = Rod-style with pressure fit flange housing 48 mm (1.88 in.) dia. SENSOR STYLES = 3 C = Rod-style 10 mm (0.39 in.) dia. damping zone 63.5 mm (2.49 in.) F = Rod-style 7 mm (0.27 in.) dia. reduced damping zone 36.5 mm (1.44 in.) D = Rod-style 7 mm (0.27 in.) dia. damping zone 63.5 mm (2.49 in.) E = Rod-style 10 mm (0.39 in.) dia. reduced damping zone 36.5 mm (1.44 in.) STROKE LENGTH (ORDER LENGTH) = 4-8 M = Millimeters 50 to 2500 mm (in 5 mm increments) CONNECTION TYPE = 9-12 N _ = Wire exit Integral 'single wires', Each conductor: 0.5 mm 2 (20 AWG) Termination type: N A = Pigtail (stripped conductors) no termination N E = 4 single wires, M12x1 IP69K, 4 pin (pin assignment 2-3-4) N G = 4 single wires, M12x1 IP69K, 4 pin (pin assignment 1-3-4) N H = 4 single wires, M12x1 IP69K, 4 pin (pin assignment 1-2-3) Wire length: 06 = 60 mm (2.36 in.) min. wire length 25 = 250 mm (9.84 in.) max. wire length Cable exit: T 4 conductor / cable; integral PUR cable, pigtailed, 4 cables, shielded. Cable length ( first digit x 1m., second digit x 0.1 m.) 10 = 1.0 m length (standard all other lengths require minimum order quantities; 0.5 m min. to 9.9 max.: 0.1 m increments). Termination type: A = Pigtail (stripped conductors) for wire termination, contact factory. INPUT VOLTAGE = 3 13 3 = 12/24 Vdc OUTPUT = 14-16 Voltage: V11 = 0.25 to 4.75 Vdc V12 = 0.5 to 4.5 Vdc V13 = 4.75 to 0.25 Vdc V14 = 4.5 to 0.5 Vdc Current: A01 = 4 to 20 ma A04 = 20 to 4 ma Product Data Sheet, Document Part No.: 550824, Revision K 1/12, 5/12, 8/12, 12/12, 6/13 (US) 6

Magnet selections and optional Test kit Model MH Rod-Style Sensor Ordering Information Magnets and the MH-Series Analog/PWM tester must be ordered separetely. Refer to the table below for ordering information. Magnet selections Part no. Ring magnet, O.D. 17.4 mm (0.68 in.) 401032 Ring magnet, O.D. 25.4 mm (0.99 in.) 400533 Ring magnet, O.D. 33 mm (1.29 in.) 201542-2 Magnet spacer 400633 Optional accessory MH-Series Analog/PWM Tester The MH-Series Tester includes: MH-Series analog / PWM Tester 12 Vdc battery charger with (adapter main plug North America, adapter main plug EU or adapter main plug UK) Cable with M12 x 1 connector Cable with pigtailed wires Carrying case CD-Rom with user s guide Part no. 280618 MH-Series Analog/PWM Tester, part no.: 280618 7 Product Data Sheet, Document Part No.: 550824, Revision K 1/12, 5/12, 8/12, 12/12, 6/13 (US)

Document Part Number: 550824, Revision K, 1/12, 05/12, 8/12, 12/12, 6/13 (US) MTS and Temposonics are registered trademarks of MTS Systems Corporation. All other trademarks are the property of their respective owners. Printed in USA. Copyright 2013 MTS Systems Corporation. All Rights Reserved in all media. SENSORS MTS Systems Corporation Sensors Division 3001 Sheldon Drive Cary, North Carolina 27513, USA Tel.: +1-800-633-7609 Fax: +1-919-677-2343 +1-800-498-4442 e-mail: sensorsinfo@mts.com http://www.mtssensors.com MTS Sensor Technologie GmbH & Co. KG Auf dem Schüffel 9 D - 58513 Lüdenscheid, Germany Tel.: +49-2351-9587-0 Fax: +49-2351-56491 e-mail: info@mtssensor.de http://www.mtssensor.de Technology Corporation 737 Aihara-cho, Machida-shi Tokyo 194-0211, Japan Tel.: +81-42-775-3838 Fax: +81-42-775-5516 e-mail: info@mtssensor.co.jp http://www.mtssensor.co.jp