KDG/KDF - Flow Meter and Flow Switch

Similar documents
GA 24 Heavy-duty variable area flowmeter

KDM ARMORED FLOW METER & SWITCH

DPT TARGET TYPE FLOWMETERS

Coriolis Flowmeters. Coriolis Flowmeters. KCM C-flow series Coriolis mass flowmeter

INSTALLATION AND OPERATION

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases

DW PADDLE-BELLOWS FLOWMETER & SWITCH

DW PADDLE-BELLOWS FLOWMETER & SWITCH

Brooks GT1000 Series. Industrial Glass Tube Variable Area Flowmeters. GT1000 Series. Data Sheet DS-VA-GT1000-eng January, 2008

RCM - Direct Reading Flowmeters

SINGLE TUBE FLOW METERS

F300 - PITOT TUBE ACRYLIC FLOWMETERS

Thermo Scientific Gilmont

King Instrument Company opened its doors in 1983 with one major goal:

ISTEC MAGNETIC METERS

Plastic tube variable area flowmeter for liquids and gases

Variable Area Flowmeters Ori-Flowrator TM Meters

mass flowmeter for compressed air

KOBOLD VKA FLOWMETER/SWITCH. User Instructions. Manual-VKA_03-04

COVOL. Operating Data. Areas of Application. Measuring Ranges. Method of Operation. Fields of operation. Features. Installation information

Variable Area Flowmeters VA Master TM Indicating Flowrator Meters 10A4500

magnetic flow meters Johannesburg (Head Office) Technical Data Safmag Wafer Type

DW PADDLE-BELLOWS FLOWMETER & SWITCH

PORTER FLOWMETERS & FLOW CONTROLLERS. Technology you can trust

DG01. Flow indicator with or without rotor, with wiper for cleaning of sight glass. Flow Metering and Monitoring Systems

Glass Tube Flowmeter Model GT1000

TECHNICAL INFORMATION LOW FLOW METER. (ethylene propylene rubber) optional. Valve trim (seat and stem) is 316 stainless.

TUBE FLOW METERS. design features INTERCHANGEABLE. 150 mm Meter with CV TM Valve

V-100 product information. Variable area flowmeters for gases and liquids

MAGNETIC LEVEL GAUGES

Ultrasonic Flowmeter. M-1500 Plus Non-invasive Inline DSP Ultrasonic Flowmeter. Operating Principle. Features

UNIVERSAL. Flow Monitors Inc. INSITE Series PX - IS - TX Flow Rate Indicators and Switches

Electromagnetic Flow Monitor magphant

RCM. Direct Reading Flowmeter. for Liquids or Gases

VA 40. Variable-area flowmeter. For explosion protected devices please refer to Supplementary Installation an Operating Instructions:

OMP Positive Displacement Flowmeters

KOBOLD SV FLOWMETER/SWITCH. User Instructions

Assembly and operating Instructions. Bypass Flow Meter DST

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet

Assembly and operating Instructions Bypass Flow Meter DST

Magnetic-inductive flow meter for hazardous areas

Distributed by: M&M Control Service, Inc Installation Instructions F-440N

BFS-10-O G1/4: BFS-10-O G1/2: BFS-10-O G1: Contact rating: BFS-10-O G1/4

Glass Tube Full-View Flowmeters

ZDM Positive Displacement Flow Meter User Instructions

Liquid filters _ 302. Deaerators. Product Bulletin

PSG5xx ATM to Medium Vacuum Gauge

Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids

QB4 PRESSURE CONTROL VALVE INSTALLATION & MAINTENANCE INSTRUCTIONS

SECTION METERS AND GAUGES FOR HVAC PIPING

INSERTION flow sensor for continuous flow measurement

Orifice plate flowmeters Series PR By-pass flowmeter for liquids, gases and steam

SINGLE-ACTING ACTUATORS FOR DOUBLE-ACTING & SERIES 65 POSITIONERS PNEUMATIC & ELECTRO-PNEUMATIC. The High Performance Company

UNIVERSAL Flow Meters

ELECTRONIC CONTROLLER

SECTION CONTROL VALVE ACTUATORS

V-Flow Line product information. Variable area flowmeters and high-precision control valves for gases and liquids

OMP POSITIVE DISPLACEMENT FLOWMETERS

Transmitting Transducer. Gas/Air Velocity Range:

Baumann Pneumatic Pressure Controller (for Industrial and Sanitary Applications)

Motorised Valve Range

PROCESS & AUTOMATED VALVES

Type 2712 (8630) Continuous TopControl System. General data Compatibility Materials of wetted parts Body Rotor Shaft Seal

Metal tube flowmeters Series M21 Variable area flowmeter for low flows of liquids, gases and steam

Positive displacement flowmeter for continuous flow measurement

ITT Conoflow Process Control Solutions

Electromagnetic Flow Monitor magphant

Model Connections Max. Flow Range (H 2 O) 10A A3220 Horizontal ¼ NPT 100 l/h. 10A3225/55 Vertical ¼ NPT 100 l/h. Vertical 1 NPT Vertical 1 G

Installation and Operating Manual

Industrial OG meter series IOG Inline and flanged oval gear meter

M-50/55 Series. Fixed setting flow switch with in-line flow

ProFlow TO BE REALLY SURE. Vane Meters. Experience in flow measurement. Introduction

KSR Flow Switches

FPD1001 thru FPD1003, FPD1102 and FPD1103, FPD1201 thru FPD1203 (includes -R Option) Positive Displacement Flowmeters

KRAL Volumeter - Turbine Fuel and Water Injection Measurement

ReguLATOR. Your Platform for Scientific Cooling SM. from. ELTA-Q Precision Flow Regulator. General Description. Features and Benefits

KEL. Heavy Duty Differential Pressure Flowmeters

Flow limiter SP/SMB10 Dual flow series

Hot Tap Insertion Vortex

Installation Instructions F-440N. Model No. F F F F F F F /16 157mm. Inline.

SECTION J CONTENTS OPTIONAL CONFIGURATIONS DESCRIPTION

Level switches Series LC40 Float level switch for liquids

CVS Rack and Pinion Pneumatic Actuator

Assembly and operating Instructions RA 60 / FA 60

Magnetic Level Gauges

BGN. All Metal Variable Area Flow Meter. Technical Data Sheet

A1 Commercial Grade Meters

PSF50 Paddle flow switch

Variable Area Flowmeters Armored Purgemeter

Paddle-wheel flow controller for On/Off control

Exercise 4-1. Flowmeters EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Rotameters. How do rotameter tubes work?

EASTERN ENERGY SERVICES PTE LTD.

Short-tube VA flow meter SGK 1-3

Flow meters, Flow switches and Flow transmitters

MT SERIES PNEUMATIC ROTARY ACTUATORS

Flow Sensors & Instruments

Flap-Type Flow Meter Prall

Flowmeters with Float. Flow Measurement of Gases & Clear Liquids with Float Series 6001 & Series 6001/ Measurement Principle.

pneumatic function fittings

NBK-M - Economical Level Indicator

Transcription:

Integral Flow Control Valve Easy to Read Scale Brass, SS, or PVDF Process Connections Direct Reading Scales for Water and Air Compact Economical Design Optional Panel Mounting Kit Optional Flow Switch output for Low Flow The KDG/KDF micro flowmeters operate on the float principle and are designed to measure low gas and liquid flows. Flow can be set exactly within the measuring range using the integral precision metering valve. The contrasting color background of the scale permits accurate data readings. Additionally, 1 or 2 adjustable switches may be mounted to identify certain flow conditions. A panel mounting kit is available as an option. Options 1. Limit Switches All meter ranges which have a stainless steel float can be fitted with optional, adjustable switches. Two types are available: Monostable: Switch activates momentarily as the stainless steel float passes by on rising flow. Bistable: Switch stays activated until the float falls past the switch on decreasing flow. Switch Specifications Output Type: NAMUR per DIN 19234 (use EX-3001 or EX-3002 as isolation relay, sold separately) 2. Junction Box A junction box is available for flowmeters with switches. The Junction-box contains a terminal block to facilitate making wiring connections. Flowmeters with switches which do not have a junction box will have wiring connections made via wire-leads fed through the bottom of the meter body. 3. Constant Flow Controllers Two types of constant flow controllers are available. Types RE and NRE upstream pressure controllers. They hold flowrate constant when there is a varying downstream pressure and constant upstream pressure. All regulators are available in nickel-plated steel or brass. 4. Panel Mounting Kit All flowmeters are available with an attached panel mounting plate and mounting hardware. The mounting plate is made of anodized Aluminum. The panel cut-out required to accommodate the panel mounting plate is 3.15 x 1.57 (80mm X 40 mm). 5. Custom Scales Custom, direct reading scales are available for the KDG and KDF series. The custom scales allow for a direct reading, calibrated for specific gravity, viscosity operating pressure or temperature. Any desired measuring units are possible. Page 1/5

Accuracy: ±2.5% full scale Repeatability: ±0.6% full scale Connection: NPT 1/4 Mounting position: Vertically, media flow from bottom to top. Max. Pressure Brass or SS Fitting: 145 PSIG PVDF Fitting: 85 PSIG Max. Temperature: 210 F Fittings: brass, 316-Ti SS, or PVDF Measuring cone: Borosilicate glass with yellow background Float stop: PVDF Gaskets: Viton, or Chemraz Valve: 316-Ti SS Contact: (optional) bistable or monostable proximity switch for units with SS floats. Page 2/5

Page 3/5

Page 4/5

Bi-stable Switch Operation Contacts are bistable ring initiators, with 2 initiators located one above the other in one housing. This pairing permits identification of the direction of movement of the float. The ring initiator thus provides bistable switch function based on the position of the float, whether above or below the initiator block. The direction of action can be reversed by turning the ring initiators around (change over top and bottom). One transistor relay (order no. Ex 3011) is required for each circuit (double version not available). Connection Diagram Page 5/5