STYLE 3491 Severe Duty Electric Mining Water Cannon INSTALLATION, AND OPERATING INSTRUCTIONS

Similar documents
STYLE 3463 FireFox. With Position Feedback Potentiometer

( Versions Available)

The following is intended to provide the basic instructions for installation, operating and maintenance of the Severe Duty Monitor.

STYLE 3462 FORESTRY BUMPER MONITOR INSTALLATION, OPERATING and MAINTENANCE INSTRUCTIONS

STYLE 3440 DECKMASTER ELECTRIC MONITOR WITH POSITION FEEDBACK INSTALLATION, OPERATING, AND MAINTENANCE INSTRUCTIONS

STYLE 3440 DECKMASTER ELECTRIC MONITOR INSTALLATION, OPERATING, AND MAINTENANCE INSTRUCTIONS

Severe Duty Water Cannon Styles 3491 & 3492 Electric & Hydraulic

Severe Duty Water Cannon Styles 3491 & 3492 Electric & Hydraulic

STYLE 5148 MERCURYMASTER OSCILLATING NOZZLE INSTALLATION, OPERATING, AND MAINTENANCE INSTRUCTIONS

STYLE 5148 MERCURYMASTER OSCILLATING NOZZLE INSTALLATION, OPERATING, AND MAINTENANCE INSTRUCTIONS

STYLE 624, 638 QUICK-ATTACK FOAM TUBE INSTALLATION, OPERATING, AND MAINTENANCE INSTRUCTIONS

ELECTRIC ACTUATOR AND CONTROLLER FOR AKRON BUTTERFLY VALVES INSTALLATION INSTRUCTIONS

: 1250 gpm in the deck mode : 800 gpm while operating in the ground base - Dual Inlet : 1000 gpm while operating in the ground base - Single Inlet

3061, 3096, 3126 foam systems gpm Installation Instructions

Product Ratings Electrical Specifications

Maximum Flow: 600 GPM (3800 LPM) Portable Base 1250 GPM (4800 LPM) Direct Mount. Maximum Pressure: 200 PSI (1380 Kpa, 13.8 BARS)

STYLE 9300 FLOW/PRESSURE METER INSTALLATION & OPERATING INSTRUCTIONS

3061, 3096, 3126 foam systems gpm Installation Instructions

3061, 3096, 3126 FOAM SYSTEMS GPM INSTALLATION INSTRUCTIONS

HALLMARK INDUSTRIES INC

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL

ULX210 COLOR CHANGING LED UNDERCAR LIGHTING SYSTEM

Users Manual Certified Series Direct Drive Pump 1-7 LPM

Spreader and Vehicle Battery Kits

DEMA MODEL 692T FOAM STATION I INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTIONS

Installation Instructions for P/N HD Water Injection Kit with 5 Gallon Tank

PPM EO-100 TM. Operation Manual

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

AKRON BRASS COMPANY PH ( ) FAX ( )

Service Guide JATCO Environmental Protection Tank Model J-7000

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Model CP420/CP425. Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual

INSTALLATION INSTRUCTIONS

4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

INSTALLATION INSTRUCTIONS

Premium Series Grease Dispensing Handle One and Two Piece Body Styles

MANUAL: Twister and BubbleCup Nozzles

This document describes:

INSTALLATION INSTRUCTIONS

Series 957, 957N, 957Z, 957RPDA, 957NRPDA, 957ZRPDA

INSTALLATION INSTRUCTIONS

Model LA 4300 Time Delay OFF Controller

Operator s Manual. Automatic Electric Jack Leveling. The leveling system shall only be operated under the following conditions:

INSTALLATION INSTRUCTIONS

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

Colt Series C400, C500

ETF-600 Sensor Operated Lavatory Faucet

INSTALLATION INSTRUCTIONS, PARTS LIST AND CONFIGURATION GUIDE FOR THE CARBONATOR. Large Model No

This document describes:

Model LA 4100 Time Delay OFF Controller

INSTALLATION INSTRUCTIONS

Installation, Operation and Maintenance Manual

WORKHORSE. Assembly / Operation Instructions / Parts

ULX210. Register your product. Send us your photos. Warranty COLOR CHANGING LED UNDERCAR LIGHTING SYSTEM. Installation Manual

For electronically controlled E4OD and 4R100 automatic transmissions ** READ ALL INSTRUCTIONS BEFORE INSTALLATION **

SUNC3000 / Item #40885

DEMA MODELS P203CTC.PI.1,.2,.3 INSTALLATION INSTRUCTIONS

DEMA MODEL 693T FOAM STATION II INSTALLATION INSTRUCTION

INSTRUCTIONS AND SERVICE MANUAL WITH PARTS LIST

DI-SP/TP. Operators Guide SUBMERSIBLE HYDRAULIC PUMPS HDI Inc. PO Box 1671 Gresham OR (FAX)

Dispenser & Warmer RIC-1909 RIC-1909EXP

INSTALLATION INSTRUCTIONS

G8 Portable Fuel Transfer Pump Owner s Manual

ISIS Power Manual and Installation Guide Race Car Replicas- Superlite Coupe

USER MANUAL. NEMA 48C Flange Mounted, Enclosed, Clutch Brake. FMCBE Model 500 FORM NO. L A (i)

LUBRICATOR GUN INSTRUCTIONS-PARTS LIST. 10,000 psi (700 bar) Maximum Delivery Pressure. Detachable-type

Single Post Caliper Brake VC500

Installation Instructions for / Universal Water/Methanol Injection Kit

Model LA 4400 Time Delay OFF Controller

TFT HAND HELD AUTOMATIC PRESSURE CONTROL NOZZLES

P SERIES PUMPS. 18mm Versions Nickle-Aluminum Bronze Models: P , P , P , P , P , P , P

Intended Use: Explanation of Signal Word Consequences

Artesian Owners Manual

Cyclone II. Cyclone. and OPERATOR S MANUAL IMPORTANT- READ OPERATOR S MANUAL BEFORE USE.

INSTALLATION INSTRUCTIONS

SOLAR ELECTRIC SUBMERSIBLE PUMP D.C. POWERED OWNERS MANUAL

TALCO FIRE SYSTEMS. LSF Start-Up Instructions. 1) IMPORTANT: Inspect the unit for damage. Report any damage to the freight carrier immediately.

Automatic Electric Jack Leveling

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Elgin Hydraulic Clutch-Brake ECB-240, Product Number FORM NO. L F FORM NO. L F-0704

Series CP200. Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual. For Models: CP218 CP219 CP220 CP230

Installation & Operation Manual. IMPORTANT: This manual contains important information. READ AND KEEP FOR REFERENCE.

EF SERIES MOTORS OPERATION & PARTS MANUAL

MODEL NUMBER: MEDIUM DUTY ONBOARD AIR SYSTEM

CAPACITOR ACTUATED PORTABLE STARTER CAPS USER GUIDE. INST048 Doc 3.01

Owner s Manual & Safety Instructions

Setup and Configuration Guide Universal Switch Interface

OWNER S MANUAL. ROTARY SURFACE CLEANER Models 105C, 105F, 105CW, & 105FW. Revision 2.01

QUALITY MISTING PUMPS

Operating Instructions and Parts Manual AHR-50 Auto Rewind Hose Reel

Tracer VM with User Interface

INSTALLATION INSTRUCTIONS

GARDEN HOSE UTILITY PUMP

Transcription:

STYLE 349 Severe Duty Electric Mining Water Cannon INSTALLATION, AND OPERATING INSTRUCTIONS Australian Only The following is intended to provide the basic instructions for installation, operating and maintenance of the Severe Duty Monitor. Tools Required o Utility knife o Medium flat screwdriver o Medium Phillips screwdriver o Small flat screwdriver o Small Phillips screwdriver o / inch hex head wrench o Electrician s pliers (multipurpose, stripping and crimping) PRODUCT RATINGS Maximum motor current draw: volt versions 5.0 amps each for elevation and rotation motors 3.0 amps for nozzle pattern motor 4 volt versions 7.5 amps each for elevation and rotation motors.5 amps for nozzle pattern motor Normal operating current (depending on operating conditions - pressure, flow, etc.): volt versions 3-0 amps each for elevation and rotation motors 0.7 amps for nozzle pattern motor 4 volt versions - 5 amps each for elevation and rotation motors 0.4 amps for nozzle pattern motor Minimum Voltage: (Truck engine must be operating for proper voltage requirement.) All volt motors:.5 volts while operating All 4 volt motors: 3 volts while operating Mass: 57 lbs. (6 kg) Maximum Flow: 750 GPM (40 lpm) Maximum Pressure: 00 PSI (4 bar) Noise Emission: 9 Db @m with maximum flow PRODUCT WARNINGS The maximum flow of the Severe Duty is 750 GPM. The center of the waterway outlet is.5 inches from the bottom of the inlet. Ensure these values and an appropriate safety factor is used to determine a proper support structure. Aim the Severe Duty in a safe direction before pumping water through it. Although the logic box includes a water resistant coating it is important to keep water out of the logic box. Prolonged exposure to water will cause damage. When the cover of the logic box is removed check that the O-Ring under the cover is intact and free of dirt and debris. The Severe Duty uses current limiting for both the monitor and nozzle stops. Use only appropriate Akron Brass nozzles. Make the connection of the vehicle and auxiliary battery the final step. If any tags or bands are worn or damaged and cannot be easily read, they should be replaced. 0956

Disconnect power and disable flow before maintenance. Keep all personnel out from the front of the outlet of the monitor when the water source is attached. Dangerous flow velocities can cause serious injury. The Severe Duty monitor contains moving parts. Keep hand, finger and objects away from pinch points. Not designed for explosive environments. Exceeding the maximum pressure and flow of the monitor or nozzle may cause damage. WARRANTY AND DISCLAIMER We warrant Akron Brass products for a period of one () year after purchase against defects in materials or workmanship. Akron Brass will repair or replace product which fails to satisfy this warranty. Repair or replacement shall be at the discretion of Akron Brass. Products must be promptly returned to Akron Brass for warranty service. We will not be responsible for: wear and tear, any improper installation, use, maintenance or storage: negligence of the owner or user; repair or modification after delivery; failure to follow our instructions or recommendations; or anything else beyond our control. WE MAKE NO WARRANTIES, EXPRESS OR IMPLIED, OTHER THAN THOSE INCLUDED IN THIS WARRANTY STATEMENT, AND WE DISCLAIM ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. Further, we will not be responsible for any consequential, incidental or indirect damages (including, but not limited to, any loss of profits) from any cause whatsoever. No person has authority to change this warranty. GENERAL INSTRUCTIONS Review the instructions, wiring diagram, component layout and rotational stops diagram before installing this unit. This unit operates on volt DC or 4 volt DC depending on the unit chosen. All electrical current flows through the wires. The monitor does not act as a ground. For use with water or standard fire fighting foams only. After use with foam, flush with fresh water. Drain the Severe Duty monitor and nozzle after use to prevent freeze damage in cold weather. Ensure that the thread in the nozzle swivel matches the thread on the Severe Duty outlet. Do not overtighten the nozzle onto the Severe Duty Monitor. The Severe Duty monitor, nozzle, logic box, control boxes, optional battery, and field adjustable rotation stops are made for optimal performance, Do not alter in any manner. Do not install shutoffs on the outlet of the Severe Duty. Mount the logic box, control boxes out of range from the monitor travel. INSTALLATION INSTRUCTIONS A. ELECTRICAL INSTALLATION STEP Plug the joystick cable connector into the logic box connector marked JOYSTICK STEP Plug the monitor harness connector to the logic box connector marked MONITOR STEP 3 Connect vehicle power to the logic box connector marked POWER NOTE: Adequately sized wire must be used based on the current requirements of the monitor. See Chart below (Figure ) Based on Vehicle Power of 3.V (V system) and 7.6V (4V system) and max currents of 30A (V system) or 5A (4V system). Wire Size (AWG) Wire Lengths (Ft.) V 4V 0 4 6 0 4 30 0 40 0 50 0 FIGURE STEP 4 Connect optional water valve harness to logic box connector marked VALVE if supplied.

B. MECHANICAL MONITOR ATTACHMENT The Monitor is to be mounted on the waterway with a NPT thread. The monitor may have an optional 3 or 4 flange with a short nipple. THE ROTATIONAL AND ELEVATION STOPS SET THE BOUNDARIES FOR THE AREA IN WHICH THE MONITOR IS ALLOWED TO TRAVEL. The monitor is shipped with rotation stops at 90 right, and at 90 left, 30 can be achieved by switching the factory set stop and the plug in the desired stop location. Both the stops and the plugs have a / inch hex head. Refer to Page 7 to determine which stop location is needed for the desired rotation. The elevation stop sets the upper limit of the elevation. The monitor is shipped with elevation stops at 90 above horizontal and 65 below horizontal. An optional stop at 0 below horizontal can be achieved by switching plugs and stops to the desired locations as indicated in figure 5. OPERATING INSTRUCTIONS A. JOYSTICK WITH TRIGGER FOR VALVE To change the nozzle pattern toward the straight stream or fog press the corresponding button on top of the Joystick. To change the horizontal position right or left move the Joystick towards the appropriate direction. To change the vertical position up or down move the Joystick forward for down and backwards for up. To open and close the valve, press the trigger to open the valve and release the trigger to close the valve. The valve can be maintained open by pressing the valve switch towards open. Note: When valve is maintained open, the trigger will not operate the valve. B. LEARN MODE (OPTIONAL) The stow position can learn a new position by pressing and holding the Stow button. When the monitor reaches the default stowed position (Straight Out), continue to hold the Stow button while operating the up or down button until the desired position. Let go of just the up or down button and that will be the new elevated stow position. While continuing to hold the stow button operating the left or right button until the desired position. Release both buttons. This will be the new stowed position. If the stowed button is released at any time during the process, stop and restart the sequence. MAINTENANCE INSTRUCTIONS Your Severe Duty monitor and nozzle should be inspected prior to and after each use, to ensure it is in good operating condition. The monitor joints were greased and sealed at assembly, there is no greasing to be done while in use. SITUATIONS THAT MAY CAUSE IRRERPAIRABLE DAMAGE Operating above maximum rated pressure and flow. Not draining, and allowing water to freeze inside. Prolonged exposure to temperatures above 30 F (54 C), or below -5 F (-3 C). Having the nozzle hit a fixed object during operating or transportation. Also there are many tell tale signs that indicate repair is in order, such as: Controls that are either inoperable or difficult to operate. Excessive wear. Poor discharge performance. Water leaks. If any of the above situations are encountered, the Severe Duty should be taken out of service, repaired, and tested by a qualified technician before placing it back in service. To replace either the horizontal or vertical rotational motors, see the technical service manual (#0960) for detailed instructions on motor and joint replacement.

Figure 4-/ 90 Left Stop Right Side Plug -/" NPT FEMALE (DO NOT PAINT) 3-9/6 Elevation Movement: +90-65 (Standard) Can Be Changed By Customer To +90-0 Front -/" NH THREAD DO NOT PAINT THIS AREA 30 Stop 90 Right Stop Right Plug Left NOTE: For 30 rotation remove both 90 Stop pins and replace with plugs. Remove plug at 30 location and install stop pin. 4-3/6 Back

Figure 3-9/3 4-/ (ROTATED 90 ) 9/3 THRU, TYP. 4 0-9/3-7/ 0 9-/ 9-/3-7/64 OPEN TRIGGER VALVE FOG STREAM READ OPERATING INSTRUCTIONS BEFORE USE -3/4

PROG RUN Figure 4 ROTATION ELEVATION PATTERN DIP SWITCHES JOYSTICK VALVE AB P/N & REV No. 4V MONITOR MFG S/N OR BATCH CODE ELEVATION ROTATION AB P/N & REV MFG S/N OR BATCH CODE LOGIC BOX DWG. D-4447 P/N 349000 DEUTSCH IPD-USA DTM04-P EXTENSION CABLE DWG. D-4449 P/N 70756 (0 FT. ) P/N 70757 (33 FT. ) P/N 7075 (40 FT. ) JOYSTICK DWG. D-4450 P/N 34900 WIRING HARNESS DWG. D-444 P/N 479

AUTO-LEVEL AUTO-LEVEL AUTO-LEVEL ON/OFF ROT OSC ON (BLK) INPUT SWITCH STOW (WHT) ROT SPEED 60% INPUT SWITCH RIGHT (BLK) ROT SPEED 0% INPUT SWITCH LEFT (RED) ELEV SPEED 60% INPUT SWITCH (BLU) ELEV SPEED 0% INPUT SWITCH (GRN) INPUT SWITCH STREAM (YEL) INPUT SWITCH FOG (BRN) FOR 40% SPEED, USE BOTH 60% & 0% INPUTS 4 3 MASTER + SYSTEM VDC VEHICLE BATTERY (+) SLAVE FROM VALVE MOTOR FROM MONITOR STYLE 3463 FIREFOX MONITOR - - + + SYSTEM VDC POWER IN AUTO-LEVEL GROUND AUTO-LEVEL +/4 VOLT (PUR) MAINTAINED INPUT SWITCH VALVE (ORG) MOMENTARY INPUT SWITCH VALVE TB3 0 3 4 5 6 7 9 0 3 4 5 6 7 7 6 5 4 3 0 9 7 6 5 TB 4 3 0 +SYSTEM VDC OUT TO SPEED SWITCH +SYSTEM VDC OUT TO SWITCHES (WHT) OSC LED (RED) VALVE LED (GRY) OSC OFF (BRN) 3 4 5 6 7 9 9 7 6 5 4 3 (BLK) VEHICLE GROUND (-) () VALVE MOTOR OPEN (ORG) ROT. MOTOR LEFT (BLK) VALVE MOTOR CLOSED (BLU) ROT. MOTOR RIGHT ELEV OSC ON (BLK) ELEV. MOTOR (RED/BLK) ROT. LIMIT SWITCH (RED) ELEV. MOTOR (GRN/BLK) ELEV. LIMIT SWITCH (GRN) PATTERN MOTOR FOG (WHT/BLK) +SYSTEM VDC OUT TO LIMIT SWITCHES (WHT) PATTERN MOTOR STREAM BLUE YELLOW ORANGE FROM CONTROL BOX/ JOYSTICK FROM JOYSTICK CONTROL BOX (WITH STOW OPTION ONLY ) FACTORY USE ONLY RUN MODE DIP FUNCTIONS = ON Water ON Only if Deployed RIGHT/LEFT Cancels Auto-osc Enable Slow Speeds Return to Stream During Stow Wide Auto-oscillation Range Use the Learned Positions Enable LEARN Mode FROM LOW SPEED SWITCH +V BULK BROWN 3 4 5 6 7 Figure 5 RED GREEN BROWN GRAY- TO VALVE LED PURPLE- TO PANEL VALVE SWITCH GRY YELLOW ORANGE GRAY -FOG - SS BROWN - TRIGGER PUR BLK RED WHT WHT GREEN GN/BK WH/BK LOCATION - LOCATION - LOCATION - LOCATION - ORANGE/ - NOT USED, CUT OFF RED RD/BK ORANGE BLUE WIRING HARNESS JOYSTICK Factory Settings 6 AWG, 0 COND. DWG D4670 LABEL REV TB RIGHT LEFT TO PANEL SWITCHES PURPLE OPEN GRAY VALVE LED +V bulk 4 AWG, COND. 4 AWG, COND. 0 AWG AWG, 4 COND.

Figure 6 STOP FOR 90fl ABOVE HORIZONTAL (STANDARD) OPTIONAL STOP LOCATION FOR -0fl BELOW HORIZONTAL -65fl BELOW HORIZONTAL (STANDARD) OPTIONAL STOP LOCATION FOR 30 ROTATION (USES ONLY STOP) STOP FOR 90 TO THE LEFT (STANDARD) STOP FOR 90 TO THE RIGHT (STANDARD) PHONE: 330.64.567 or 00..6 I FAX: 330.64.944 or 00.53.7335 I akronbrass.com revised: 6/0 WARRANTY AND DISCLAIMER: We warrant Akron Brass products for a period of five (5) years after purchase against defects in materials or workmanship. Akron Brass will repair or replace product which fails to satisfy this warranty. Repair or replacement shall be at the discretion of Akron Brass. Products must be promptly returned to Akron Brass for warranty service. We will not be responsible for: wear and tear; any improper installation, use, maintenance or storage; negligence of the owner or user; repair or modification after delivery; damage; failure to follow our instructions or recommendations; or anything else beyond our control. WE MAKE NO WARRANTIES, EXPRESS OR IMPLIED, OTHER THAN THOSE INCLUDED IN THIS WARRANTY STATEMENT, AND WE DISCLAIM ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE. Further, we will not be responsible for any consequential, incidental or indirect damages (including, but not limited to, any loss of profits) from any cause whatsoever. No person has authority to change this warranty. ISO 900 REGISTERED COMPANY Akron Brass Company. 000 All rights reserved. No portion of this can be reproduced without the express written consent of Akron Brass Company.