COUPLING NX5 SERIES COMBINED 3-PHASE COUPLING/DECOUPLING NETWORKS FOR BURST AND SURGE TESTING UP TO 5.5 KV

Similar documents
COUPLING NX5 SERIES COMBINED 3-PHASE COUPLING/DECOUPLING NETWORKS FOR BURST AND SURGE TESTING UP TO 5.5 KV

YOUR PARTNER FOR IMPULSE EMC EMC PARTNER PRODUCT RANGES. Immunity Lightning Component Emission Automation

Typical electrical schematic Maximum continuous operating voltage: 250V, 50/60Hz

Indoor Linear 50W Driver SI-CU WW

High Performance Vector Control Drive Manual Supplement

Output Current Input Current Reflected Ripple. VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf %

Surge-Trap Pluggable STPT2 Series - 40kA

Power Quality Products FN 5040 HV. LC Sine Wave Filter for 600 VAC and 690 VAC Motor Drives Applications. Typical applications. Features and benefits

Output Current Input Current Reflected Ripple. Efficiency (typ.) (Range) VDC VDC ma ma(typ.) ma(typ.) ma(typ.) VDC μf % MTQZ50-72S05

Output Current Input Current Reflected Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S033

6,000 on-off operations according to UL 1054, TV5 10,000 on-off operations according to ENEC. Features and benefits

VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S

Dual stage filter Ultra compact design Rated currents up to 10A. Dual fuse holder 2-pole rocker switch

Output Current Input Current Over Load VDC VDC ma ma(typ.) ma(typ.) VDC μf %

C B. Operating up to 5000m altitude 5 year product warranty Models

Technical specifications

3 Phase Power Systems - Designed for Canada

General Performance EMC/EMI Filter with Earth Line Choke

Outdoor 200 W 2 Channel SL-L2701B0N1KR

Output Current Input Current Reflected Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma (typ.) VDC μf % MKW40-12S033

Efficiency (typ.) (Range) Output Voltage Current. Input Current Load VDC VDC ma ma ma(typ.) ma(typ.) ma(typ.

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

Output Voltage Current. Input Current Ripple. Efficiency (typ.) Load VDC VDC ma ma ma(typ.) ma(typ.) ma(typ.) μf % 2.

(typ.) (Range) Input Specifications Parameter Model Min. Typ. Max. Unit 12V Input Models Input Surge Voltage (100ms.

Products and solutions for photovoltaic applications

EMC Filter FC-CxxD Series

Open Frame Power Supplies

Installation Manual. YASKAWA AC Drive Option Back-up Capacitor Unit for Momentary Power Loss. Type: P0010, P0020

PDL09-48 S 05 M Series Name Input Output Output Case Voltage Quantity Voltage Option PART NUMBER STRUCTURE

Electronic Braking Systems

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter

Type AVS SMT Aluminum Electrolytic Capacitors - General Purpose, 85 C

EUROTHERM ONTROLS. Two phase thyristor power switches. Product data

EMC/EMI Filter for PV Inverters

Advanced Small Cell with XP Technology

Switching Power Supplies

Load (2) Single or Dual

UV- TECHNOLOGY. Technical Documentation ELC N6 / ELC N8 / ELC N10

Power Generation for the Offshore Oil & Gas Industry. C175 Offshore Generator Set

S24SP series 40W Single Output DC/DC Converter

IRT 4000 AT-S/M/L. Technical Manual. quality IN MOTION. quality IN MOTION

XM2-HP and XM2 CableUPS

GB60S 60W Single Output General Purpose Series

PU SERIES 1W UNREGULATED

The first in the world!

Smart Battery Systems. for Energy Storage

(typ.) (Range) Load

DC/DC Converter URB1D_LMD-10WR3 Series

(typ.) (Range) ±18 330# 89 MPW MPW

FHSCP-UNV-10P-L-SD SPECIFICATIONS

LBC S102G 8000 W Ethernet CAN bus on request. LBC S101G W CAN bus Ethernet on request

SolarMax 20C/25C/30C/35C. Proven reliability.

EPS/ELA-Series User Manual EPS/ELA 250W

Phoenix Inverter

DEWS SERIES 25W-30W WIDE INPUT RANGE

MODEL POWER BATTERY VOLTAGE COMMUNICATION. LBC SxxxG* 8000 W 110 V CAN or Ethernet. LBC SxxxG* W 110 V CAN or Ethernet

FINHRM FINHRM5 FINHRMA FINHRMAC

Valve monitoring system VDK 200 A S02

-Shape the Future with Manufacturing Technology

Motor Starter Reverse MSR22-FBP

HS6B Subminiature Interlock Switches

SolarMax 330TS-SV. The all-round solution for large-scale PV installations.

Combined instrument transformers

Industrial Power Supplies

RPS TL-UL System. Solutions for the North American Solar Market

Alpha EM DC Multi-Function DC Energy Meter. Technical Datasheet. Compact DC Energy Meter

DH50 SERIES. DATASHEET Rev. A

DC/DC Converter URF48_QB-200W(F/H)R3 Series

Agilent 4UHV Ion Pump Controller. For Ultra High Vacuum

PRODUCT SPECIFICATION File: EA-520H1U-01 Date: Apr., 7, 2005

RDL06-48 S 05 W - M3 Series Name Input Output Output Input Operating ambient Voltage Quantity Voltage Range temperature PART NUMBER STRUCTURE

Uninterruptible power supply (UPS) S8BA & BU_2RWL series

Switching Power Supplies

1 second start up, no external components 220µF <1 second start up + diode protection circuit 6800µF

SDS05-48 S 05 W H Series Name Input Output Output Input Isolation Voltage Quantity Voltage Range Option PART NUMBER STRUCTURE

SolarMax S series (United Kingdom) Maximising solar plant yields can be so easy.

MOTOMAN-EPH and EP Series

Application. Battery. Public Grid GS HYBRID INVERTER

Maxwell s Highest Power and Energy Cell

Power Supplies POWER SUPPLIES TRANSIENT VOLTAGE SUPPRESSORS POWER LINE FILTERS. AC to DC Power Supply Units. AC to 24VDC Regulated Primary Switching

ISO Interface. Large capacity. Light weight. Accommodates enclosure IP65. Solenoid Valve (with M Connector) Conforming to ISO

Tel: &

ESS Batteries by Samsung SDI

PDL03-48 S 05 W H Series Name Input Output Output Input Isolation Voltage Quantity Voltage Range Option PART NUMBER STRUCTURE

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

Applications. Overview. Technical Specifications

3 Uninterruptible Power Systems

GE Energy Industrial Solutions. EV Charging Station. Application Guide. imagination at work

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,

MAKING MODERN LIVING POSSIBLE. UniLynx Indoor Installation Manual. ULX 1800i ULX 3000i ULX 3600i ULX 5400i SOLAR INVERTERS

MMA. Insertion Resistance Thermometers. with, or without transmitter. OEconomically-priced O thermometers with optional plug-on display

Uninterruptible Power Supplies

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

High performance Vector Control. Ratings. System configuration

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

Multi Function Efficient Dynamic Altitude Simulation MEDAS

TOP SMART intelligent position monitor:

Uninterruptible (ATX) Switching Power Supply. MODEL eups-350

CBI All in One DC UPS Power Solutions

Liebert PowerSure PSI UPS

Transcription:

COUPLING NX5 SERIES COMBINED 3-PHASE COUPLING/DECOUPLING NETWORKS FOR BURST AND SURGE TESTING UP TO 5.5 KV FOR TESTS ACCORDING TO... > EN 50121 > EN 50121-3-2 > EN 50121-4 > EN 50121-5 > EN 61000-4-4 > EN 61000-4-5 > EN 61000-6-1 > EN 61000-6-2 > EN 61543 > IEC 60601-1-2 > IEC 61000-4-12 > IEC 61000-4-4 > IEC 61000-4-5 > IEC 61008-1 > IEC 61009-1 > IEC 61326 > IEC 61850-3 > ITU-T K.20 > ITU-T K.21 > ITU-T K.45 COUPLING/DECOUPLING NETWORKS FOR EFT/BURST AND SURGE The three-phase coupling/decoupling networks of the coupling NX series are used to couple EFT/Burst pulses and Surge pulses on DC-lines or to three-phase (4-wire or 5-wire) mains supply systems for voltages up to 1,000 VDC / 3 x 690 VAC. This includes the more and more common testing of inverters used in the area of renewable energies (e.g. photovoltaic systems, wind power stations, electric cars). Full compliance over a wide range of EUT current, within 16A, 32 A, 63 A, 125 A and settings. Higher current ratings on request. HIGHLIGHTS > Automatic coupler for Burst and Surge APPLICATION AREAS INDUSTRY RESIDENTIAL MEDICAL RENEWABLE ENERGY > Model with range selection 32, 63, 125 and > Meet requirements for 3x690 VAC and 1,000 VDC > LEDs indicate active mode and coupling > Automatic selection of Surge impedance > Fully remote controlled by EM TEST compact NX BROADCAST TELECOM > Option for railway application as per EN 50121 EM TEST > PAGE 1/8

BENEFITS COUPLER FOR RAILWAY APPLICATION The coupling NX-series coupling/decoupling networks are built fully compliant to the standard requirements of EN/IEC 61000-4-4 and EN/IEC 61000-4-5. Residual voltage levels are carefully considered as well as the value of the decoupling inductors in order to meet the requirements with regard to voltage drop at the rated current of each type of CDN. For surge testing according the railway standard EN 50121 an additional coupling RC impedance of 0.5 µf and 40 ohm is required. Being fully controlled by the related generators, couplings of the coupling NX are set automatically as selected for the test (either by manual operation or via software). When performing surge tests the generators will automatically set the required source impedance depending on the standard and the coupling mode. This special impedance network is already implemented in the 3-phase couplers for railway application. This railway coupling is automatic offeed in the menu of the NX generators and the iec.control software. Figure A shows the coupling with the special railway coupling impedance module of 0.5 µf /40 ohm. Figure B shows the standard surge coupling with 18 µf for line to line coupling and the coupling impedance for line to ground coupling using 9 µf /10 ohm. Models are available with multiple current ranges with waveshape specification that are fully compliant to IEC 61000-4-5. in each selectable EUT current range. Offering the advantage that nearly all EUT's can be tested with just one CDN! EM TEST > PAGE 2/8

MODEL OVERVIEW MODELS FOR RAILWAY APPLICATION GENERAL INFORMATION FOR ALL CDN GENERAL INFORMATION FOR ALL RAILWAY CDN Burst EN/IEC 61000-4-4, up to 5.5 kv Coupling Surge EN/IEC 61000-4-5, up to 5 kv * <32 A: 0 A to 32 A 63 A: >32 A to 63 A 125 A: >63 A to 125 A : >125 A to built in module with 0.5 µf / 40 Ohm for railway applications according EN 50121; Burst EN/IEC 61000-4-4, up to 5.5 kv Surge EN/IEC 61000-4-5, up to 5 kv *s <32 A: 0 A to 32 A 63 A: >32 A to 63 A 125 A: >63 A to 125 A : >125 A to MODELS FOR 3 X 480 VAC (P-P) Model 16 A coupling NX5 bs-3-480-16 32 A coupling NX5 bs-3-480-32 MODELS FOR 3 X 480 VAC (P-P) 63 A coupling NX5 bs-3-480-63 Model 125 A coupling NX5 bs-3-480-125 16 A coupling NX5-R bs-3-480-16 with additional current ranges* 32 A coupling NX5-R bs-3-480-32 coupling NX5 bs-3-480-63.1 with additional current ranges* coupling NX5 bs-3-480-125.1 coupling NX5-R bs-3-480-63.1 coupling NX5 bs-3-480-200.1 coupling NX5-R bs-3-480-125.1 coupling NX5-R bs-3-480-200.1 MODELS FOR 3 X 690 VAC (P-P) Model MODELS FOR 3 X 690 VAC (P-P) 16 A coupling NX5 bs-3-690-16 32 A coupling NX5 bs-3-690-32 Models with additional current ranges* coupling NX5-R bs-3-690-63.1 coupling NX5-R bs-3-690-125.1 coupling NX5-R bs-3-690-200.1 with additional current ranges* coupling NX5 bs-3-690-63.1 coupling NX5 bs-3-690-125.1 coupling NX5 bs-3-690-200.1 MODELS FOR 3 X 690 VAC (P-P); 1,000 VDC MODELS FOR 3 X 690 VAC (P-P); 1,000 VDC Model 16 A coupling NX5 bs-3-690-16.2 32 A coupling NX5 bs-3-690-32.2 with additional current ranges* Models with additional current ranges* coupling NX5-R bs-3-690-63.3 coupling NX5-R bs-3-690-125.3 coupling NX5-R bs-3-690-200.3 coupling NX5 bs-3-690-63.3 coupling NX5 bs-3-690-125.3 RAILWAY COUPLER FOR MANUAL APPLICATION coupling NX5 bs-3-690-200.3 PCN 7-R s-1 Manual Coupling network, 7 kv surge pulse, EUT max. 690 VAC Coupling: 0.5 uf / 40 Ohm, Decoupling: Generator internal CDN EM TEST > PAGE 3/8

(480 V MODELS) (480 V MODELS WITH ADDITIONAL RANGES) COUPLING NX5 BS-3-480-16 3 x 480 V, 16 A, 50/60 Hz IN : MC Safety plug 4 mm, Size: 19" / 6 HU, 448 x 286 x 500 mm, Weight: approx. 30 kg COUPLING NX5 BS-3-480-63.1 3 x 480 V, 63 A, 50/60 Hz s* <32 A, 63 A IN : CEE 480/63, Weight: approx. 100 kg COUPLING NX5 BS-3-480-32 3 x 480 V, 32 A, 50/60 Hz IN : MC Safety plug 4 mm, Size: 19" / 6 HU, 448 x 286 x 500 mm, Weight: approx. 45 kg COUPLING NX5 BS-3-480-125.1 3 x 480 V, 125 A, 50/60 Hz s* <32 A, 63 A, 125 A IN : CEE 480/125, Weight: approx. 180 kg COUPLING NX5 BS-3-480-63 3 x 480 V, 63 A, 50/60 Hz IN : CEE 480/63, Size: RAC 25 IEC included, Weight: approx. 100 kg COUPLING NX5 BS-3-480-125 3 x 480 V, 125 A, 50/60 Hz IN : CEE 480/125, Size: RAC 25 IEC included, Weight: approx. 200 kg COUPLING NX5 BS-3-480-200.1 3 x 480 V,, 50/60 Hz s* <32 A, 63 A, 125 A, IN : MC Safety plug 10 mm, OUT: MC Safety plug 10 mm Weight: approx. 200 kg EM TEST > PAGE 4/8

GENERATORS FOR 690 V CDN'S (690 V MODELS WITH ADDITIONAL RANGES) GENERATOR REQUIREMENTS FOR 690 V MODEL CDN'S AC voltage requirements Coupling/decouplung networks for 3 x 690 VAC require a transient gerator rated for 400 VAC voltage. compact NX series Suitable generators for 3 x 690 VAC CDN's: - compact NX5 bsp-1-400-16, - compact NX5 bsp-1-400-32, - compact NX5 bspt-1-400-32 COUPLING NX5 BS-3-690-63.1 3 x 690 V, 63 A, 50/60 Hz s* <32 A, 63 A N : CEE 690/63, Weight: approx. 120 kg (690 V MODELS) COUPLING NX5 BS-3-690-125.1 COUPLING NX5 BS-3-690-16 Burst up to 5.5kV 3 x 690 V, 125 A, 50/60 Hz 3 x 690 V, 16 A AC s* <32 A, 63 A, 125 A IN : MC Safety plug 4 mm, N : CEE 690/125, Size: 19" / 6 HU Weight: approx. 30 kg Weight: approx. 190 kg COUPLING NX5 BS-3-690-32 COUPLING NX5 BS-3-690-200.1 3 x 690 V, 32 A, 50/60 Hz 3 x 690 V,, 50/60 Hz IN : MC Safety plug 4 mm, s* <32 A, 63 A, 125 A, Size: 19" / 6 HU Weight: approx. 30 kg IN : MC Safety plug 10 mm, OUT: MC Safety plug 10 mm Weight: approx. 220 kg EM TEST > PAGE 5/8

(690 VAC AND 1,000 VDC MODELS) (690 VAC AND 1,000 VDC MODELS WITH ADDITIONAL RANGES) COUPLING NX5 BS-3-690-16.2 3 x 690 V, 16 A, 50/60 Hz, 1,000 VDC, 16 A IN (AC): CEE 690/16, IN (DC): MC Safety plug 4 mm, Weight: approx. 120 kg COUPLING NX5 BS-3-690-32.2 3 x 690 V, 32 A, 50/60 Hz 1,000 VDC, 32 A IN (AC): CEE 690/32, IN (DC): MC Safety plug 4 mm, Weight: approx. 140 kg COUPLING NX5 BS-3-690-63.3 3 x 690 V, 63 A, 50/60 Hz 1,000 VDC, 63 A IN (AC): CEE 690/63, IN (DC): MC Safety plug 6 mm, s* <32 A, 63 A Weight: approx. 180 kg COUPLING NX5 BS-3-690-125.3 3 x 690 V, 125 A, 50/60 Hz 1,000 VDC, 125 A IN (AC): CEE 690/125, IN (DC): MC Safety plug 6 mm, s* <32 A, 63 A, 125 A Weight: approx. 250 kg COUPLING NX5 BS-3-690-200.3 3 x 690 V,, 50/60 Hz, 1,000 VDC, IN (AC): MC Safety plug 10 mm, IN (DC): MC Safety plug 10 mm, OUT: MC Safety plug 10 mm s* <32 A, 63 A, 125 A, Weight: approx. 290 kg EM TEST > PAGE 6/8

FOR MODEL FOR DC APPLICATION GENERAL DATA INTERFACES COUPLING FOR DC APPLICATION coupling NX5-DC bs-1-1000-32 1-phase 5 kv coupling/decoupling network for the compact NX5 & NX7 series,,, Coupling DC+, DC- and PE (all combinations), Nominal voltage 1.000 VDC, Nominal current 32 A, With TEST ON function sys.link 26 pin high density connector to control an external devices connector EUT supply 3 x 480 V, CEE plug, 16 A to 125 A, 3 x 690 V, CEE plug, 16 A to 63 A, plugs for all other current ratings connector to EUT up to 32 A: 4 mm safety plug, 63 A: 6 mm safety plug, 125 A: 6 mm safety plug, : 10 mm safety plug MAINS (CONTROL) OPTIONS OPTIONS RAC 25 IEC RAC 34 IEC RAC 38 IEC Rack 19", 25 HU, 1317 x 553 x 800 mm (HxWxD), for coupling NX and one generator (e.g. compact NX5) Supply voltage 85 V - 264 V Frequency 50/60 Hz Power approx. 75 W Standby: 100 ma Fuses 115 V: 2 x 4 A slow blow, 230 V: 2 x 2 A slow blow SAFETY Safety standard IEC/EN 61010 Rack 19", 34 HU, 1717 x 553 x 800 mm (HxWxD), for coupling NX and one generator (e.g. compact NX5) or several standalone generators Security circuit Control input (24 VDC) Warning lamp Floating contact (max. 60 V/2 A) Rack 19", 38 HU, 1895 x 553 x 800 mm (HxWxD), for coupling NX for and one generator (e.g. compact NX5) or several standalone generators Temperature 10 C to 35 C Humidity 30 % to 75 %, non condensing Atmospheric pressure 86 kpa (860 mbar) to 106 kpa (1,060 mbar) ENVIRONMENT SAFETY OPTIONS ESS 1 Emergency switch (short circuit), cable 3 m SWL AD Safety warning lamp adapter, voltage free contact SWL Safety warning lamp, red / green requires ext supply 24 VDC, 1,6 A EM TEST > PAGE 7/8

COMPETENCE WHEREVER YOU ARE CONTACT EM TEST DIRECTLY Switzerland P.R. China AMETEK CTS GmbH > Sternenhofstraße 15 > 4153 Reinach > Switzerland Phone +41 (0)61 204 41 11 > Fax +41 (0)61 204 41 00 Internet: www.ametek-cts.com > E-mail: sales.conducted.cts@ametek.com AMETEK Commercial Enterprise (Shanhai) Co. Ltd.> Beijing Branch> Western Section, 2nd floor> Jing Dong Fang Building (B10)> Chaoyang District>Beijing, China, 100015 Phone +86 10 8526 2111 > Fax +86 (0)10 82 67 62 38 Internet: www.ametek-cts.com > E-mail: chinasales@ametek.com Germany AMETEK CTS Europe GmbH > Customer Care Center EMEA > Lünener Straße 211 > 59174 Kamen > Germany Phone +49 (0) 2307 26070-0 > Fax +49 (0) 2307 17050 Internet: www.ametek-cts.com > E-mail: info.cts.de@ametek.com Poland AMETEK CTS Europe GmbH > Biuro w Polsce > ul. Twarda 44 > 00-831 Warsaw > Poland Phone +48 (0) 518 643 12 Internet: www.ametek-cts.com > E-mail: Infopolska.cts@ametek.com USA / Canada AMETEK CTS US > 52 Mayfield Ave > Edison > NJ 08837 > USA Phone +1 732 417 0501 Internet: www.ametek-cts.com > E-mail: usasales.cts@ametek.com Republic of Korea EM TEST Korea Limited > #405 > WooYeon Plaza > #986-8 > YoungDeok-dong > Giheung-gu > Yongin-si > Gyeonggi-do > Korea Phone +82 (31) 216 8616 > Fax +82 (31) 216 8616 Internet: www.emtest.co.kr > E-mail: sales@emtest.co.kr Singapore AMETEK Singapore Pte. Ltd > No. 43 Changi South Avenue 2 > 04-01 Singapore 48164 Internet: www.ametek-cts.com > E-mail: singaporesales.cts@ametek.com Great Britain AMETEK GB > 5 Ashville Way > Molly Millars Lane > Wokingham > Berkshire RG41 2 PL > Great Britain Phone +44 845 074 0660 Internet: www.ametek-cts.com Information about scope of delivery, visual design and technical data correspond with the state of development at time of release. Subject to change without further notice. EM TEST > PAGE 8/8