Truck Hydraulics Auxiliary valves. Technical Information Ordering information and Drawings...60

Similar documents
- BPV-F1-25 and BPV-F BPV-F1/-T BPV-T BPV-L, line mounted BPV-VP

Truck Accessories. Fittings, Adaptor kits and accessories for F1, F2, T1 and VP1 pumps

Truck Hydraulics. F1 F2 T1 VP1 PTO info Accessories. Fixed and Variable Displacement Pumps, Motors and Accessories. Catalogue HY /UK April 2003

Hydraulic Pump Series F1plus Fixed Displacement

Installation and Startup Manual Hydraulic Pumps Series VP1-095 /-110/ -130

Hydraulic Pump Series VP1 Variable Displacement

Truck Hydraulics. Series GPA, GP1, F1, F2, T1, VP1, Fixed and Variable Displacement Pumps, Motors and Accessories

Truck Hydraulics. Serie VP1 Variable Displacement Pumps

Contents Page Chapter. - Volvo PTO s Scania PTO s Universal for Scania ED 90 engines for Scania ED 120 engines...

Truck Hydraulics. Series GPA, GP1, F1, F2, T1, VP1, Fixed and Variable Displacement Pumps, Motors and Accessories

Truck Hydraulics. Series GPA, GP1, F1, T1, F2, F3, VP1, Fixed and Variable Displacement Pumps, Motors and Accessories. parker.

Hydraulic Pump VP1-120

Truck Hydraulics. Series F1, F2, T1 Fixed Displacement Pumps

September 2012 JLe HIGH PRESSURE PUMP HPW 1600/ (LS)

Hydraulic Motor Series V12 Variable Displacement

SPECIFICATIONS AND OUTLINE DIMENSIONS

MODEL DIMENSIONS, mm WEIGHT OIL FILL L W H A B C D E kg l HK 450/ x ,9

MODEL DIMENSIONS, mm WEIGHT OIL FILL L W H A B C D E kg l HK 450/ x ,9

GENERAL PUMPA member of the Interpump Group

SPECIFICATIONS AND OUTLINE DIMENSIONS

HWB Series GENERAL PUMP. Hydraulic Drive Triplex Plunger Pump INDUSTRIAL INDUSTRIAL FEATURES

TXV - Characteristics

Hydraulic Motors. Series V12, V14, T12 Variable Displacement

P2060 P2075 P2105 P2145 P3105 P3145

Gear Pumps. Series PGP Fixed Displacement Pumps, Cast-Iron Designs

Series P2/P3 Variable Volume Piston Pumps

Section 35 Chapter 2 HYDRAULIC SYSTEM HOW IT WORKS AND TROUBLESHOOTING NH

POWERSHIFT TRANSMISSION

Hydraulic Motor/Pump. Series F11/F12 Fixed Displacement. parker.com/pmde

HPV-15 AXIAL PISTON PUMPS

HPV-10 AXIAL PISTON PUMPS

OUTLINE DIMENSIONS HIGH PRESSURE PUMP HDF 40/40-8 1/6. High pressure pump HDF 40/40-8. HYDRAULIC FLOW l/min, max. 10. HYDRAULIC PRESSURE bar, max.

PARTS & ASSEMBLY DRAWINGS SECTION 1. Jacket

Hydraulic Motors. Series V12, V14, T12 Variable Displacement

HPV-15 AXIAL PISTON PUMPS

COMPRESSORS 09/97 CB-5C-050. Suggested Spare Parts for LB601 and LB601A Compressors: Qty./ Unit

Hydraulic Motor/Pump. Series F11/F12 Fixed Displacement. parker.com/pmde

Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI

Hydraulic Motor/Pump. Series F11/F12 Fixed Displacement. parker.com/pmde

Hydraulic Motor/Pump. Series F11/F12 Fixed Displacement

MP18/SIC & SIO Stacking Valve System Technical Information Manual

Section 6.1. Implement Circuit - General System. General: TF Configuration TB Configurations Implement Control Valve:

CDM CREEPDRIVE MOTOR

Mobile Motor/Pump. Accessories

Pilot-Operated Directional Control Valves Series D3 - D11

LHD. Spare parts list 23 M. Rock drills Construction Tools PC AB No

Extremely compact in size to allow direct flange-mounting on vehicle engine or gearbox PTOs.

Modular Unit 6MB HYDRANOR MODULAR UNIT 6MB GENERAL DESCRIPTION. 6MB-200-**-2C General Arrangement. Rev

HYDRAULIC OIL PUMPS AND MOTORS PRODUCT CATALOG. Hybel - Hydraulic Oil Pumps and Motors

Gear Pumps / Motors. Series PGP / PGM Fixed Displacement Pumps, Cast-Iron and Aluminium Designs

Vickers. Overhaul Manual. Vane Pumps. Small and Large Series Combination Pumps VC(K)(S)-**-(*)*D*-6(1) VC(K)(S)-**-(*)-*-*D*-5(1)

HOT WATER PRESSURE WASHER

Service Manual Series F12

CS-SCB Sander Control Block Manual

Torque Converter, Transmission Pump, Screen And Filter

Variable Displacement Pumps

Introduction. General Information. Systems Operation

MP18 Stacking Valve System Technical Information Manual

Catalog HY /US SERIES CAVITY DESCRIPTION FLOW PRESSURE PAGE NO. LPM/GPM BAR/PSI

Hydrostatic Power Train

Solenoid valve VDHT standard BSP (British Standard Pipe)

Slip-in Cartridge Valves Series CE, CP. General Description. Features. Pilot Control for Directional Functions

SD3E-B2. Functional Description. 2/2 Way Solenoid Operated Directional Control Valves Poppet Type HA /2012. Replaces HA /2010

Produktová rada MP1. Miroslav Chmatil.

Solenoid valve VDHT standard BSP (British Standard Pipe)

DISAB P 210/ ADR

VARIABLE PUMPS FOR CLOSED LOOP OPERATION type HV-02

CUMMINS ENGINE ISX15 ISX CM2250 Service Workshop Manual

Hyva Hoses & Adapters Introduction

HYDRAULIC VARIABLE PUMPS

Spare parts for SMC & TSMC 108 Mk3 Type S-L and E

HP3V SERIES. Swash-plate Type Axial Piston Variable Displacement Pump

Directional Seat Valve Series D4S (Denison)

Service and Parts Manual. Minimum Filtration Required:

Hydraulic Motor/Pump Series F11/F12 zp12

Yarway 7100 Series ARC Valve non-filtered design Installation and maintenance instructions

Spare parts list. Hydraulic Power Pack PAC P 13. Chicago Pneumatic Construction Tools

Miniature coil (3W) encapsulated in synthetic material. Connection with 3-pin DIN type B plug. Degree of protection IP 65.

LOAD SENSE SECTIONS. Series 20. Directional Control Valves NEED NEW PIC VALVES STANDARD FEATURES SPECIFICATIONS

Pyrolance, LLC PTO-HYDRAULIC DRIVEN ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B 2000 M-P

XPi series. the intelligent pump. fixed displacement bent axis design. XPi - Presentation ADVANTAGES

Spare parts list. Centrifugal pumps CP

Dash8-200/300 - Auxiliary Power Unit APU CONTROLS AND INDICATORS. Page 1

LB361B PARTS LIST COMPRESSORS CB-5E /06. Bulletins Needed For Complete Parts List. Gasket Set, Repair Kits and Special Tools

Spare parts list. Hydraulic Power Pack PAC P 18. Chicago Pneumatic Construction Tools

Hand-operated Hydraulic Control Valve 4- way 2-position 4 Ports

Series 810: 2 Way Angle Body Valves: 1/4 to 3 NPT

Output flow In l/min at 1500 min

Spare parts manual. HPX700Mk5 Reciprocating compressor unit

LB601B PARTS LIST COMPRESSORS CB-5E /06. Bulletins Needed For Complete Parts List. Gasket Set, Repair Kits and Special Tools

TPV 1000 (Ex 6-18) Variable Displacement Closed Loop System Axial Piston Pump HY-TRANS THE PRODUCTION LINE OF HANSA-TMP HT 16 / M / 109 / 1008 / E

GENSET ENGINE-G25/30. ITEM PART NO. DESCRIPTION QTY QTY REMARKS No. G25 G30

Section 10. Pressure Adjustments For: L90F-622 LUMBERJACK

MICRO RAIN 50,58,&63 SPARE PARTS MANUAL JANUARY 1, 2005

PM 1744 B49/B54/58T FM PARTS MANUAL

SERIES GARDEN TRACTORS 1992 PARTS CATALOGUE CONTENTS

Series 90 Axial Piston Motors. Technical Information

Sectional Directional Control Valve RSQ 240

CHARACTERISTICS ACCESSORIES. High Efficiency Pilot Operated Safety Valves

2.3 MEDIUM HEAVY DUTY SERIES

Transcription:

Index Auxiliary Valves Bypass Valves and Unloading Valves for F1, F2, T1 and VP1 pumps Contents Page BPV-F1 and BPV-T1 bypass...59...59 Ordering information and Drawings...60 BPV-F1 and BPV-T1 Bypass without manual override...60 BPV-F1 Bypass with manual override...60 BPV-F2 bypass...61 Ordering information and Drawings...62 BPV-F2 Bypass without manual override...62...62-63 Ordering information and Drawings...62-63 BPV-F2 Bypass with manual override...63 BPV-F1, -T1 and -F2 Accessories / Spare Parts...64 BPV-L line mounted bypass...65 BPV-VP1 unloading...66 58 Parker Hannifin

BPV-F1 and BPV-T1 bypass The bypass is mainly utilised in applications where the F1 pump is driven from the crank-shaft through a cardan shaft, or when it is installed on an engine PTO. The BPV bypass should be engaged during transportation when the pump is operating constantly and the engine is running at max rpm; the hydraulic system is not sized for the large flow that would otherwise go through it. The BPV substantially reduces the energy loss during transportation. The installs directly on top of the pump end cap with a pressure port banjo fitting and an inlet port spacer bushing with two cap screws; refer to the illustration to the right. As the BPV is symmetrical, it can be turned 180 to prevent interference with chassis components; it can be utilised for either left hand or right hand pumps. The function must only be activated or released (by means of the 24 VDC solenoid) at no-load (below 20 bar) system pressure. IMPORTANT INFORMATION - In order to secure a cooling flow through the system, a separate drain line must be connected from the BPV-F1 drain line fitting directly to tank; (shown in the Installation Information Bulletin HY30-8227-INST/UK/ DE) refer also to the schematic. - The pressure connector must be tightened (to 50 Nm) before the suction fitting clamp screws are tightened. Pilot operated check Solenoid Directional control ( open centre ) F1 pump Valve block Drain port (External line) Bypass schematic. Suction adapter Holddown clamp (x2) O-ring (x3) Spacer bushing Pump suction port q BSP 1" (BSP 3/4") Pressure connector Valve body 39 (39) O-ring (x2) (F1 end cap) Pump pressure port 12 59 Parker Hannifin

Ordering information and Drawings BPV-F1 and BPV-T1 Bypass Without manual override Bypass, type Max pressure, continuous intermittent Solenoid voltage (option) Power requirement Operating mode Bypass BPV-F1, BPV-T1 Voltage 24 VDC 12 VDC 24 VDC 12 VDC Drain fitting kit F1-025 Drain fitting kit other F1, T1 and F2 Ordering number 378 7201 378 7202 378 7203 378 7204 1) Torque pressure connector to: For F1 and T1 size F1-25, -41, -51, -61 and T1-81 F1-81, -101 and T1-121 BPV-F1 and BPV-T1 Bypass With manual override Bypass, type Max pressure, continuous intermittent Solenoid voltage Power requirement Operating mode BPV-F1-25 to -101 and BPV-T1-81 and -121 350 bar 400 bar 24 VDC, (12 VDC) 14 W Activated solenoid: Check closed Torque 1) 50 Nm 100 Nm 378 1640 Contains a drain line fitting a bonded seal and nozzle. 378 3039 Contains a drain line fitting and a bonded seal. BPV-F1-25 to -101 and BPV-T1-81 and -121 350 bar 400 bar 24 VDC 14 W Activated solenoid: Check closed Solenoid Valve housing Drain port (plugged); BSP 1/4" Hold-down clamp (x2) Cap screw (x2) NOTE: 105 (103) Dimensions are shown for BPV-F1-81 (those for BPV-F1-25 are in parenthesis) 110 (109) IMPORTANT: Always tighten the pressure connector before tightening the cap screws. Also, see table to the left. BPV-F1 and -T1 installation and cross section without manual override Connector (included) Solenoid Connector (included) Manual override Bypass BPV-F1, BPV-T1 Voltage Ordering number For F1 and T1 size 24 VDC 378 4179 F1-25, -41, -51, -61 and T1-81 24 VDC 378 4180 F1-81, -101 and T1-121 Drain fitting kit F1-025 Drain fitting kit other F1, T1 and F2 1) Torque pressure connector to: Torque 1) 50 Nm 100 Nm 378 1640 Contains a drain line fitting a bonded seal and nozzle. 378 3039 Contains a drain line fitting and a bonded seal. Valve housing Drain port (plugged); BSP 1/4" Hold-down clamp (x2) Cap screw (x2) 105 (103) 110 (109) IMPORTANT: Always tighten the pressure connector before tightening the cap screws. Also, see table to the left. NOTE: Dimensions are shown for BPV-F1-81 (those for BPV-F1-25 are in parenthesis) BPV-F1 installation and cross section with manual override 60 Parker Hannifin

BPV-F2 bypass An F2 twin pump fitted with a bypass can be utilised in applications where the pump is operating constantly i.e. when the pump is driven from the crankshaft through a cardan shaft, or when it is installed on an engine-pto. In addition, it can be used when, temporarily, one of the two circuits is not required; the power loss is thus reduced as the non-required flow is not forced through lines and open center s. The BPV bypass should be engaged during transportation when the pump is operating constantly and the engine is running at max rpm; the hydraulic system is not sized for the large flow that would otherwise go through it. The BPV connects the outlet and inlet ports of the pump, and only a small oil flow goes through the system and to the reservoir. The is installed directly on top of the pump port surface with banjo fittings and two cap screws (refer to the split view to the right). As the BPV is symmetrical it can be turned 180 so as not to interfere with chassis components.the can accommodate left hand as well as right hand rotating pumps. The can only be engaged or disengaged ( through the 24 or 12 VDC solenoid) at low system pressures (below 20 bar). F2-twin-flow pump A B Pilot operated check Solenoid (24 or 12 VDC) BPV-F2 Bypass circuit schematic (example). Directional control s ( open centre ) Separate drain line BPV_F2plus_schem_GB.eps IMPORTANT INFORMATION - In order to secure a cooling flow through the system, a separate drain line must be connected from the BPV-F2 drain line fitting (shown in the split view) directly to tank; refer also to the schematic. - The pressure connectors must be tightened (to 50 Nm) before the suction fitting clamp screws are tightened. 12 61 Parker Hannifin

Ordering information and Drawings BPV-F2 Bypass Without manual override Bypass, type Max pressure, continuous intermittent Solenoid voltage (option) Power requirement Operating mode Bypass Voltage Ordering 1) number BPV-F2, 24 VDC 12 VDC 378 7424 378 7425 1) The BPV-F2 kit contains parts designated 1 in the split view to the right. 2) A suction fitting kit (parts designated 2 in the split view) is not included with the F2 pump; it must be ordered separately (refer to chapter 11). 3) Torque pressure connector to: BPV-F2 350 bar 400 bar 24 VDC, (12 VDC) 14 W (each solenoid) Activated solenoid: Check closed For F2 size Torque 3) 42/42, 53/53, 55/28, 70/35, 70/70 50 Nm 1 -BPV-F2 kit Cap screw 1) Pressure connector (x2) 1) 2 - Suction fitting kit Suction fitting 2) Hold-down clamp (x2) 1) Drain line (not included) to be connected directly to tank O-ring 2) Drain line fitting 1) (BSP 1/4") Bonded seal 1) Valve blocksub-assy 1) Solenoid (x2) 1) ; (connector included) O-ring (x4) 1) Plug with bonded seal 1) Spacer bushing 1) O-ring (x2) 1) Bypass split view without manual override (with F2 end cap). NOTE: A suction fitting kit (parts designated 2 in the split view) is not included with the F2 pump; it must be ordered separately (refer to chapter 11). 62 Parker Hannifin

Ordering information and Drawings BPV-F2 Bypass With manual override Bypass, type Max pressure, continuous intermittent Solenoid voltage Power requirement Operating mode Bypass For F2 size Torque 3) 1) Voltage Ordering number BPV-F2, 24 VDC 378 4377 42/42, 53/53, 55/28, 70/35, 70/70 50 Nm 1) The BPV-F2 kit contains parts designated 1 in the split view to the right. 2) A suction fitting kit (parts designated 2 in the split view) is not included with the F2 pump; it must be ordered separately (refer to chapter 11). 3) Torque pressure connector to: BPV-F2 350 bar 400 bar 24 VDC 14 W (each solenoid) Activated solenoid: Check closed 1 -BPV-F2 kit Cap screw 1) Pressure connector (x2) 1) 2 - Suction fitting kit Suction fitting 2) Hold-down clamp (x2) 1) Drain line (not included) to be connected directly to tank O-ring 2) Drain line fitting 1) (BSP 1/4") Bonded seal 1) Valve blocksub-assy 1) Solenoid (x2) 1) ; (connector included) Manual override O-ring (x4) 1) Plug with bonded seal 1) Spacer bushing 1) O-ring (x2) 1) Bypass split view with manual override (with F2 end cap). NOTE: A suction fitting kit (parts designated 2 in the split view) is not included with the F2 pump; it must be ordered separately (refer to chapter 11). 12 Manual override 63 Parker Hannifin

BPV-F1, -T1, -F2 and -F3 Accessories / Spare Parts Part No Description Remarks 3787496 Solenoid 24V Incl. new connector 3787497 Solenoid 12V Incl. new connector 3787494 Cartridge Incl. new connector assy 24V 3787495 Cartridge Incl. new connector assy 12V 3785948 Nut for cartridge 3787488 Male contact kit Solenoid Male contact kit Nut Tighten to 8 ± 1 Nm Cartridge assy Tighten to 46 ± 3 Nm Remember to lubricate the seal on the cartridge before assembly in the block. Part No Description Remarks 3781480 Inlet union screw F2 (all sizes) 3781082 Inlet union screw F1-25, -41, -51, -61 and T1-81 3781094 Inlet union screw F1-81, -101, T1-121, and F3-81, -101 3780641 O-ring kit For F1, T1, F2 and F3 (all sizes) 3782439 Hold-down clamp Suction fitting 1) For BPV F1, T1, F2 and F3 1) Hold-down clamp for suction fitting on bypass for F1, T1, F2 and F3 (parts designated 1 in the split view). Flange clamp 1) Inlet union screw O-ring Screw 1) O-ring 1) 64 Parker Hannifin

BPV-L line mounted bypass The unloading BPV-L is utilised in hydraulic systems where the fixed displacement pump is engaged constantly and no flow is required, i.e. during transportation. The flow is directed through the unloading which has a low pressure loss and less heat is being generated in the system. When the solenoid is activated the unloading closes and the pump flow is directed to the directional control or other user. Unloading Gauge port G Directional control ( open centre ) Solenoid Unloading, type BPV-L Max operating pressure [bar] 350 Max flow [l/min] 250 Solenoid voltage [VDC] 24 Required power [W] 14 Operating mode Activated solenoid: Check closed Ordering number 378 1487 Solenoid (24 VDC standard); connector included φ 9 (x2) 100 62 'UT' 50 45 10 10 45 100 'IN' BSP 1"(x2) Gauge port (BSP 1/4") 12 65 Parker Hannifin

VP1 installation on an engine PTO BPV-VP1 unloading The BPV-VP1 unloading is utilized in hydraulic systems where the pump is in constant operation. The protects the pump from being overheated in the off-load mode by allowing a small flow through the pump. When load sensing function is engaged, the bypass flow is cut off (as port X is being pressurized). The will also de-air the suction line and the pump body after a long standstill. (The pump is assembled above the oil-tank and during the standstill some of the oil in the pump housing has been drained back to the oil-tank) Valve type Ordering number BPV-VP1 379 8799 NOTE: - BPV-VP1 with VP1-45 or -75 and - BPV-VP1 with VP1-095, -110 or -130, see next page. BPV-VP1 unloading 30 S 51.5 X 32 T P 8.5 40 41 53 BSP 1/4" φ 6.5 (x3) (x2) 92 BPV-VP1 unloading. For more information also see HY30-8226-INST/UK, Installation Information Unloading Valve BPV for VP1 9 66 Parker Hannifin

T T BVP-VP1 with VP1-45/75 pumps Port T (BSP 1/4") Must be connected directly to tank! Port LS (BSP 1/4") Pressure port (BSP 1") VP1-045 or -075 pump Fitting with orifice (included) BPV-VP1 unloading (5 bar) Load sensing Suction port (BSP 1 1/4") Port M (BSP 1/4") NOTE: - Install the fitting (included) in port M and connect it, in turn, to port S of the unloading (see schematic). - An orifice is included in the fitting. S X P T Load sensing (LS) line BPV-VP1 installation schematic with VP1-45/-75 pump. VP1-45/-75 end view (showing ports). BPV-VP1 with VP1-095/-110/-130 pumps Port M (BSP 1/4") Install fitting! VP1-095/ -110/-130 pump Fitting with orifice (included) BPV-VP1 unloading (5 bar) Load sensing M Pressure port (BSP 1") LS S X T P T Left hand rotating pump Suction port Right hand rotating pump VP1-095/-110/-130 main ports (with fitting installation). Load sensing (LS) line BPV-VP1 BPV-VP1-095_schematic.ai installation with VP1-095/-110/-130 pump. NOTE: - Install the fitting (included) in port M and connect it, in turn, to port S of the unloading (see schematic). - An orifice is included in the fitting. LS Port LS (BSP 1/4") Alternative Port T (BSP 1/4"); 12 LS port Must be connected directly to tank! VP1-095/-110/-130 control ports. 67 Parker Hannifin