ø10 A1 Series Miniature Control Units

Similar documents
ø8 A8 Series Miniature Control Units

ø12 A2 Series Miniature Control Units

Bright illumination face and snap-action switching.

Miniature Switches & Pilot Devices

UP Series Miniature Pilot Lights

A series Switches & Pilot Lights

AP/UP Series Miniature Pilot Lights UZ Series Miniature Buzzer

Oiltight Switches & Pilot Devices

A Series. Miniature Control Units

RU Series Universal Relays

Switches & Pilot Devices

XA Series Emergency Stop Switches (w/removable Contact Block)

AP Series / UP Series Miniature Pilot Lights UZ Series Miniature Buzzer

HS5D Miniature Interlock Switches

MW Series Control Units

ø22mm HW Series Control Units

HS5E Miniature Interlock Switches with Solenoid

[ Bezel size ] [ From panel front ] [ Shape ] [ Contact rating ] [ Action ] Unibody

Style Contact Type No. Button Color Code ø40mm Mushroom 1NC YW1B-V4E01R YW1B-V4E21R. Gasket ø40 YW1L-V4E11Q0R 2NC YW1L-V4E02Q➂R 6 (12V AC/DC)

Relays & Sockets. RR Series Power Relays. Part Number Selection. Key features: Sockets IDEC (4332) USA & Canada

XW Series Emergency Stop Switches

22mm Push Buttons and Switches

We Make It Easy! 3. All of our switches are shipped complete, just as ordered. No incomplete or partial deliveries of subcomponents and accessories

Distinctive Characteristics

Distinctive Characteristics

NO NO NO. Standard Interlock Safety Switches HS6B. HS5E-K Key Locking Safety Interlock Switches

Lighted Pushbutton Switch

Relays. Industrial Automation Catalog Section - U906. Selection Guides. General Purpose Relays RU Series RR Series

Distinctive Characteristics

LW Series offer flexibility in space-saving package

EXCEL CELL ELECTRONIC CO., LTD. NO. A S P E C I F I C A T I O N Edition 2 Page 1

ø22mm HW Series Control Units Control Units

Distinctive Characteristics

HMI Components. Series. Indicator Illuminated pushbutton Mushroom-head pushbutton Key lock switch

HS5E Miniature Interlock Switches with Solenoid

HS1L Interlock Switches with Solenoid

Lighted PushButton Switch

Emergency Stop Switch A165E. Ordering Information. Mounting Aperture of 16 mm

Switches & Pilot Devices

HS6E Subminiture Interlock Switches with Solenoid

HS1E Interlock Swithes with Solenoid

Relays & Sockets. RQ Series PCB Relays

Standard Interlock Safety Switches

Switches & Pilot Devices

MC SERIES. Illuminated Control Units. Super LED or Incandescent Illumination Removable Contact Blocks

10 AMP POWER RELAY. Breakdown voltage* 2. Operate time* 3 (at nominal voltage) Shock resistance. Vibration resistance. Unit weight

HS1C-P Interlock Plug Unit with Door Lock

HS1C Interlock Switches with Solenoid

A165-E. Ordering Information. Emergency Stop Switch. For Panel Cutout of 16 mm

HS1E-K Interlock Switches with Solenoid (3-circuit)

Oiltight Switches & Pilot Devices

HL (AZH) LIMIT SWITCHES

Features. Emergency Stop Switch A22E. Install in 22-dia. or 25-dia. Panel Cutout. Safety Lock Mechanism to Prevent Misuse.

General Purpose Relay

Non-illuminated Push Buttons

RY2L Series Miniature Magnetic Latching Relays. E Release Time. 60N (0 6G); Maximum frequency 55Hz

HS5D Miniature Interlock Switches

Sealed type washable 1C H-1C-C 812H-1C-V 812H-1C-S (SPDT) F 812H-1C-C F 812H-1C-V F 812H-1C-S F

SG-B1 SERIES / SG-A1 SERIES

Switches & Pilot Devices

A22NK. Key-type Selector Switches

Oiltight Switches & Pilot Devices

HS1C Series Full Size Interlock Switch with Locking Solenoid. GS-ET-15 BG standard in Germany. HS1C Series Functionality

Emergency Stop Switches Selection Guide

Safety Products. Safety Products. HS5E Series. HS5E Series Miniature Solenoid Locking Switch

Mounting type Contact form PCB terminals Screw terminals Quick-connect terminals

Door Interlock Switches

HS1E Series Full Size Solenoid Locking Switches

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions Accessories

General Specifications

Emergency Stop Switches

Distinctive Characteristics

Distinctive Characteristics

HL (AZH) Limit Switches

Enabling Switches Grip Style Enabling Switches

YB2 Panel Seal. New Square Actuator Option. Series YB2. Contact No Thin Flush Mount Pushbuttons. 24mm Square Panel Seal Pushbuttons

Model Number Structure

3.2. Pushbuttons. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents

HS1E Series Full Size Interlock Switch with Locking Solenoid

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions...

1 Form A 5A small size power relay for interface

HS2B N B - R. Door Interlock Switches. HS2B Series. Full Size Interlock Switch. Part Number. HS2B features: Part Number Key.

A22/M22. Specifications. Specifications Common to All. Complete Assemblies

General Specifications

General Specifications

Load Resistive load (p.f. = 1) Inductive load (p.f. = 0.40, L/R = 7 ms) Rated load 5 A at 250 VAC, 30 VDC 2 A at 250 VAC, 30 VDC

Ordering Information. Snap Action Switch D2F. Subminiature Snap Action Switch D2F- Model Number Legend. Snap Action Switch D2F 31

Door Interlock Switches

Series AV. Pushbutton Switches NUT O-RING HOW TO ORDER

HS1B R - R. Door Interlock Switches. HS1B Series. HS1B Series Full Size Interlock Switch. Part Number. HS1B features: Part Number Key.

Miniature Switches & Pilot Devices

panasonic.net/id/pidsx/global Solve issues related to machine safety and other safety measures with a safety door switch with key!

Emergency Stop Pushbutton Switches (22-dia. or 25-dia.) A22E/A22NE-P

Power PCB Relay. Type Contact material Contact form Construction Part number General purpose AgCdO SPDT Semi-sealed G2R-1

Section. Safety Products Selection Guide...B-2

Safety Interlock Switches

FLAT/VERTICAL TYPE HIGH POWER BIFURCATED CONTACT

Indicator body single with two independent lamp bases, raised, rectangular, black plastic, screw terminals, without bezel. Part No

Subminiature Basic Switch

Type Terminal Coil Contact form Model

Transcription:

A1 ø10 A1 Series Miniature Control Short 22-mm-long body miniature control unit series with LED illumination face and snap-action switching. Bright and clear LED illumination. All series have terminals on the same plane. UL recognized, CSA certified Applicable Standards Mark File No. or Organization UL508 UL Recognition File No. E55996 CSA C22.2 No.14 CSA File No. LR 21451 Flush Silhouette Switches & Pilot Lights Lights LED Safety Products Contact Ratings (Contact Block) Rated Insulation Voltage 250V Rated Thermal Current 3A Operating Voltage (AC/DC) 24V 110V 220V AC 50/60 Hz Resistive Load 1.0A 0.5A Inductive Load 0.7A 0.5A DC Resistive Load 1.0A 0.2A Inductive Load 0.7A 0.1A Contact Material Silver Minimum applicable load: 5V AC/DC, 3 ma (applicable range may vary with operating conditions and load types) Weight Weight (approx.) AL1M-M11: 3g AL1M-P1: 3g AB1M-M1: 3g Specifications Operating Temperature 25 to +55 C (no freezing) Storage Temperature 30 to +80 C (no freezing) Operating Humidity 45 to 85% RH (no condensation) Contact Resistance 50 m maximum (initial value) Insulation Resistance 100 M minimum (500V DC megger) Between live and dead metal parts: 2,000V AC, 1 minute Between terminals of different poles: 2,000V AC, 1 minute Switch Unit Dielectric Between terminals of the same pole: Strength 1,000V AC, 1 minute Between contact and lamp terminals: 1,500V AC, 1 minute Between live part and ground: Unit 2,000V AC, 1 minute Damage Limits, Operating extremes: Vibration Resistance 5 to 55 Hz, amplitude 0.75 mm Damage limits: 500 m/s Shock Resistance 2 (50G) Operating extremes: 200 m/s 2 (20G) Mechanical Durability Momentary: 200,000 operations (minimum operations) Maintained: 100,000 operations Momentary: 100,000 operations Electrical Durability Maintained: 50,000 operations (minimum operations) (Switching frequency 1200 operations/h) Degree of Protection IP40 (IEC 60529) Terminal Blocks Comm. Terminals AS-Interface Relays & Timers Sockets Circuit Protectors Power Supplies PLCs & SmartRelay Operator Interfaces Sensors LED Ratings (LAD-S) Built-in LED Part No. LAD-SA LAD-SG LAD-SR LAD-SY Base Exclusive for A series control units Forward Current (If) 20 ma Forward Voltage (Vf) (nominal) 2.2V 2.1V 1.7V 2.2V Reverse Voltage (Vr) 4V Color A G R Y LED Color Amber Clear Yellow Diffused Red Clear Yellow Clear Applicable Lens Color Amber Green Red Yellow and White Base Plastic Color Red LED Life (reference value) Approx. 50,000 hours (The illuminance reduces to 50% of the initial intensity when used on complete DC.) Operating Voltage & External Current-limiting Resistor (recommended value) (Note) 5V DC: 150, 1/2W 6V DC: 200, 1/2W 12V DC: 510, 1W 24V DC: 1.1 k, 1W Control Stations Explosion Protection References Internal Circuit (+) ( ) Note: When LED lamps are used on voltages other than the above, external resistor value R is determined by the following formula: R = (operating voltage Vf) / If LED lamps do not have a current-limiting resistor, and external resistors of recommended values for each voltage must be provided. Connect a current-limiting resistor in series, otherwise LED lamps will be damaged. Because no protection diode is contained, ensure the correct polarity is observed. (+) Current Limiting Resistor Terminal (+) ( ) Terminal ( ) 157

ø10 A1 Series Illuminated Pushbuttons & Pilot Lights Illuminated Pushbuttons & Pilot Lights Shape Operation Contact Part No. IP40 AL1M Momentary SPDT AL1M-M11 Lens Color Code Package Quantity: 1 LED Part No., Rated Current (External Resistor Recommended Value) Maintained SPDT AL1M-A11 Pilot Light AL1M-P1 AL1Q Momentary SPDT AL1Q-M11 Maintained SPDT AL1Q-A11 Pilot Light AL1Q-P1 AL1H Momentary SPDT AL1H-M11 Specify a color code in place of in the Part No. A: LAD-SA G: LAD-SG R: LAD-SR W/Y: LAD-SY Rated Current: 20 ma 5V DC: 150, 1/2W 6V DC: 200, 1/2W 12V DC: 510, 1W 24V DC: 1.1 k, 1W Maintained SPDT AL1H-A11 Pilot Light AL1H-P1 LED lamps do not have a current-limiting resistor. Connect a current-limiting resistor in series, otherwise LED lamps will be damaged. AP1M series pilot lights (round bezel only) with built-in current-limiting resistor are also available. Dimensions (+) ( ) Panel Thickness 0.5 to 6 Locking Ring Terminal Width 1.8 0.4t 12 6 5.5 16 c12 5.5 22 9 Terminal Arrangement (bottom view) NC Mounting Hole Layout / Terminal (+) NO COM Terminal ( ) 16 min. Note: Determine mounting centers to ensure easy operation. 158

A1 A1 Series Pushbuttons ø10 Pushbuttons AB1M AB1Q AB1H Shape Button Style Operation Contact Button Lens Button Lens Button Lens Specify a color code in place of or in the Part No. Dimensions Part No. IP40 Momentary SPDT AB1M-M1 Maintained SPDT AB1M-A1 Momentary SPDT AB1M-M1L Maintained SPDT AB1M-A1L Momentary SPDT AB1Q-M1 Maintained SPDT AB1Q-A1 Momentary SPDT AB1Q-M1L Maintained SPDT AB1Q-A1L Momentary SPDT AB1H-M1 Maintained SPDT AB1H-A1 Momentary SPDT AB1H-M1L Maintained SPDT AB1H-A1L Package Quantity: 1 Color Code B black S: blue B black S: blue B black S: blue Flush Silhouette Switches & Pilot Lights Lights LED Safety Products Terminal Blocks Comm. Terminals AS-Interface Relays & Timers Sockets Circuit Protectors Power Supplies PLCs & SmartRelay Panel Thickness 0.5 to 6 Operator Interfaces Locking Ring Terminal Width 1.8 0.4t Sensors 12 Control Stations 6 5.5 5.5 22 9 16 c12 Explosion Protection Terminal Arrangement (bottom view) Mounting Hole Layout References / NC NO COM 16 min. Note: Determine mounting centers to ensure easy operation. 159

ø10 A1 Series Accessories Accessories Locking Ring Wrench Shape Material Part No. 60 Lens Removal Tool Metal (nickel-plated brass) Ordering No. Package Quantity MT-003 MT-003 1 Remarks Used to tighten the locking ring when installing the A1 control units into a panel. Stainless Steel MT-101 MT-101 1 Used to remove lens and button. 60 Holder Tool Rubber OR-66 OR-66 1 Used to remove and install LED lamps. 70 Switch Guard 90 open For round/ square unit For rectangular unit AL-K1 AL-K1 1 AL-KH1 AL-KH1 1 Used to protect pushbuttons from inadvertent operation. See page 161 for dimensions. (remains 90 open) Socket Terminal Cover Mounting Hole Plug Solder Terminal AL-C1 AL-C1 1 PC Board Terminal AL-C1V AL-C1V 1 Nylon AL-V1 AL-V1PN10 10 Snaps on the rear of the A1 series control units. (see page 161 for dimensions) When wiring the terminals, insert the lead wires into the terminal cover holes before soldering. Terminal cover is not attached and must be ordered separately. Degree of protection: IP65 Nitryl rubber (black) AL-B1 AL-B1PN05 5 2 4.4 160

A1 A1 Series Maintenance Parts ø10 Dimensions Switch Guard Flush Silhouette For / (AL-K1) 12 For (AL-KH1) 16 Panel Thickness 24.5 0.5 to 5 Switches & Pilot Lights 10 10 Lights 1 20.5 min. 1 20.5 min. 12.5 LED 13 min. 17 min. Socket (AL-C1, AL-C1V) Safety Products 33 7.3 33 Terminal 0.8 0.3t 7.3 Terminal Arrangement NC Terminal Blocks NO Comm. Terminals 17 5 11 17 3 5-1.0 0 Holes Terminal (+) COM Terminal ( ) AS-Interface Terminal Cover Solder Terminal (AL-C1) PC Board Terminal (AL-C1V) (PC Board Terminal Mounting Hole Layout) (Bottom View) Relays & Timers 17.3 Sockets ø10.8 Note: When wiring the terminals, insert the lead wires into the terminal cover holes before soldering. Circuit Protectors 33.5 Power Supplies Maintenance Parts PLCs & SmartRelay Shape Part No. Ordering No. Marking Plate AL1M-W AL1M-WPN05 AL1Q-W AL1Q-WPN05 AL1H-W AL1H-WPN05 Package Quantity 5 White Color Code Lens Unit AL1M-LK1- AL1M-LK1- PN02 Specify a color code in place of in the Part No. AL1Q-LK1- AL1Q-LK1- PN02 A (amber), G (green), R (red) AL1H-LK1- AL1H-LK1- PN02 W (white), Y (yellow) 2 Button Unit AB1M-BK1- AB1M-BK1- PN02 Specify a color code in place of in the Part No. AB1Q-BK1- AB1Q-BK1- PN02 B (black), G (green), R (red) AB1H-BK1- AB1H-BK1- PN02 S (blue), W (white), Y (yellow) LED Current-limiting resistor is not contained. 5.3 9.0 ø4.0 color: amber color: green color: red color: yellow LAD-SA LAD-SG LAD-SR LAD-SY LAD-SA 1 LAD-SAPN10 10 LAD-SG 1 LAD-SGPN10 10 LAD-SR 1 LAD-SRPN10 10 LAD-SY 1 LAD-SYPN10 10 Lens color Amber Green Red White/ Yellow LED color: amber clear LED color: yellow diffused LED color: clear red LED color: yellow clear Operator Interfaces Sensors Control Stations Explosion Protection References 161

ø10 A1 Series Instructions Safety Precautions Turn off the power to A series control units before starting installation, removal, wiring, maintenance, and inspection of the control units. Failure to turn power off may cause electrical shocks or fi re hazard. To avoid burning your hand, use the lamp holder tool when replacing lamps. For wiring, use wires of a proper gauge to meet the voltage and current requirements. Failure to tighten terminal screws may cause overheating and create a fi re hazard. Operating Instructions Replacement of Lens and Marking Plate Removal Remove the lens assembly (color lens, marking plate, lens holder, and spring) by holding the color lens recesses with the Lens Removal Tool (MT-101) and pulling it out. Remove the marking plate by disengaging the latches between the color lens and lens holder. The marking plate must be engraved on the front side as shown below. Note: Make sure that the spring is inserted in the correct direction. The base of spring must fit the groove in the holder. Installation Place the marking plate on the lens holder in the correct direction, and press the color lens onto the lens holder to engage the latches. Put the spring on the lens holder and insert the lens holder into the housing in the correct direction. Installing Non-illuminated Button Non-illuminated pushbuttons contain a marking plate like illuminated units. Be sure to install the marking plate when replacing the button. Marking For A series illuminated pushbuttons, legends and symbols can be engraved on the built-in marking plates, or printed fi lm can be inserted under the lens. Marking Plate & Lens Built-in Marking Plate ø 0.8 Latches Color lens Marking Plate Size: ø8.5 must be made on the engraving area less than 0.5mm deep. The marking plate is made of white acrylic resin. Replacing the LED 0.8 Spring Lens Retaining Holder Groove Removal Use the lamp holder tool (OR-66) to remove lamps. Do not use pliers. Installation Use the lamp holder tool (OR-66) to install lamps. Note the correct side of the tool for removal or installation. Holder Tool OR-66 (ø8, ø10, series) Size: 8.5 Spring 0.8 11.5 Size: 12.5 x 8.5 Panel Mounting When mounting the control units into a panel, use the optional locking ring wrench (MT-003) to tighten the locking ring. Do not use pliers. Tightening torque must not exceed 0.29 N m. Excessive tightening will damage the locking ring. Wiring Solder the terminal at 350 C within 3 seconds using a 60W soldering iron. Sn-Ag-Cu is recommended when using lead-free solder. When soldering, do not touch the control unit with the soldering iron. Also ensure that no tensile force is applied to the terminal. Do not bend the terminal or apply excessive force to the terminal. Use non-corrosive rosin fl ux. Installing the Socket Install the socket on the control unit with the TOP markings on the control unit and the socket placed in the same direction. Operating Voltage of LED s The operating voltage is measured at complete DC. When using a pulsating voltage such as a full-wave rectifi cation voltage, keep peak currents within the forward current If. Peak currents exceeding the If may shorten the LED lamp life. Other Notes Close Proximity Mounting When mounting pilot lights or illuminated pushbuttons collectively or lighting them continuously, heat may cause the ambient temperature to rise above the rated operating temperature. When the mounting panel is not made of metal or when the control units are mounted in an enclosed panel, provide for ventilation or lower the operating voltage. Replacement of Buttons (Illuminated/Non-illuminated) Do not replace buttons of maintained action units while the button is in the locked position. Replacing the button in the locked position may damage the internal mechanism. Be sure to release the button before replacing. Operating and Storage Environment 1. Make sure that the operating/storage temperature and humidity are within the ratings. 2. Do not use enclosed type units in an environment subject to oil, water or dust accumulation. Microswitch Contacts Do not connect NO and NC contacts of the microswitch to different voltages or different power sources to prevent a dead short-circuit. For removing lamps For installing lamps 162