HYDRUS ULTRASONIC METER

Similar documents
HYDRUS ULTRASONIC METER

CORONA E ELECTRONIC METER MULTI-JET

WESAN WPV E ELECTRONIC METER WOLTMAN

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

CORONA ER ELECTRONIC METER MULTI-JET

RAY COMPACT ENERGY METER MECHANICAL

RAY MECHANICAL COMPACT METER. 4 MID approved class 2 from DN 15mm qp 0,6m3/h up to DN 40mm qp 10m3/h

SHARKY FS 473 ULTRASONIC FLOW SENSOR

SonoMeter 30 Energy Meters

SonoMeter 30 Energy Meters

EW447-EW452 Series Mechanical Heat Meters FOR HEATING AND COOLING APPLICATIONS

SonoSensor 30 Ultrasonic flow sensor

WESAN WP 222. Bulk Water Meter Woltman

EW130 Series Multijet Water Meters DN15 40 FOR COLD AND WARM POTABLE WATER APPLICATIONS

WZMC-402 Ultrasonic Apartment Energy Meters

US-S/FFL. Ultrasonic energy meters. Function. Flexible design. Connection. Mounting. High reliability

TOPAS PMW-basic. Customer benefits. Product features

aquaconcept Product features Customer benefits

WESAN WP WOLTMAN METER

Metering systems 0578EN January 2014 Thermal energy meters, ultrasounds type for use in a boiler room GE552-1 series

Domestic Water Meter. Elin Wasserwerkstechnik. Contact Water Meter MTM for cold water. Features

Datasheet PDCSY-MW-U. Technical Overview. Features. Product warranty and total quality commitment.

MULTICAL 62 DATA SHEET. Application

WSTH/WPTH. Woltmann type combined energy meter. Measuring distance. Function. Connection. High reliability. Mounting.

Superstatic 440. Static Heat Meter, Static Cooling Meter. Application

STUF-280W. Features: Ultrasonic Water Meter, DN15~DN40. Ultrasonic Water Meter DN50~DN600

Horizontal Distribution Units - HDU Multi-port

Screw-type and measuring capsule heat meter with IrDA interface and an interface for retrofitting external modules or with integrated communication.

TOPAS PMW-basic Hot water meter

a q u a c o n c e p t Applications Features Benefits

Hello, I am the new Zelsius C5 heat meter. The new generation of ultrasonic heat and cooling meters for precise energy consumption measurement.

Fluidic Oscillation Compact Heat Meter

Water Metering THE WORLD S MOST ACCURATE COMMERCIAL HYBRID METER

MagFlux Q 8200 Series

Compact Static Heat Meter of High-Tech Composite

Residential Water Meters

Supercal 539 Universal compact heat meter

Heat Meter Integrator

WATERFLUX 3070 Technical Datasheet

Superstatic 440. Static Heat- and Cooling Meter. Application

Superstatic 749. Fluidic Oscillation Compact Heat Meter

Fluidic Oscillation Compact Heat Meter of High-Tech Composite

WSTH/WPTH. Woltmann type combined energy meter. Woltmann flow meters for large nominal flows combined with calculator and temperature sensors.

Electronic Water Meters

Installation & Maintenance Instructions MULTICAL 403. Supplied by. .com. Call us on +44 (0)

FH8500. Metering Solution for Custody Transfer Applications. One Step Ahead in Ultrasonic Flowmetering. Main Applications

Magnetic Paddle Flow Sensor/Switch for Easy On/Off Control

Measuring capsule heat meter G54 / G55

Service instructions. MAGNA Series 2000

SERIES PR90H PROGRAMMABLE INCREMENTAL HOLLOW SHAFT ENCODER FOR INDUSTRIAL APPLICATIONS REFERENCE PR90H - C C - C. External diameter 58 mm

WATERFLUX 3070 Technical Datasheet

SensoStar C. Installation and Operating Instructions Heat Meter Calculator Heat/Cooling Meter Calculator Cooling Meter Calculator

Supercal 539. Compact thermal energy meter

BERMAD Waterworks. Insertion Flow Meter Device (IFM)

IFX-M4-03 IFX-M4-03_D_E_2017_05_REV.0

Paddle-wheel flow controller with optical principle for On/Off control

Ultrasonic heat meter

Options guide. Electromagnetic flowmeters. M9xx

tprime TM Series 280T

HYDROMETER. Operating Instructions Edition 03/ Revision 05. Ultrasonic flowmeter type SHARKY 475 [ ] A5E HYDRO.PS.022.Q5.

Series 7000 Torque Sensor for PTO-shafts

Compact Heat Meters. Features. -A Pulsed output. -B M-Bus output. Accessories. UK Sales Tel: International Tel:

UL6300 SONICMAX. Ultrasonic Clamp-on Flowmeter OUTLINE FEATURES STANDARD SPECIFICATION. Common specification

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

Installation & User Guide. Multical 801. (Heating & Cooling) Supplied by. .com. Call us on +44 (0)

ProMinent Sigma/ 1 Motor Diaphragm Metering Pumps

ULTRASONIC HEAT METER

Heating Cost Allocation Valve with local acquisition of the flow temperature

BAYLAN AUTOMATED TEST BENCH

ProMinent Sigma/ 3 Motor Diaphragm Metering Pumps

Marsh McBirney Flo-Dar

ULTRASONIC FLOW SENSOR IFX-M4-01

MULTICAL 6M2. Data sheet

Series 7000 Torque Sensor for PTO-shafts

Application. Battery. Public Grid GS HYBRID INVERTER

ThermoPro TM Series TP10

Heat / Chill Meter PolluCom M Installation and Operating Instructions. PolluCom M. Installation and Operating Instructions. M H 1210 INT, Page 1

VZ-01. Features. Oil Counter for Light to Heavy Fuel Oil. Description: Application: / Mounting on pressure or suction side

Product information. MIRA-P Poultry computer

Analog Input Terminal

The Polaris MA1 is the first liquid flow meter offered by Magnetrol, expanding the already diverse level and flow measurement portfolio that has been

fluid technology temperature sensors 1600 intelligent temperature sensor membrane keyboard, USB opto interface

Datasheet PDCSY-MW-CHM. Technical Overview. Features. Product warranty and total quality commitment. General Information.

SonoSelect and SonoSafe energy meters

CB-005N Circuit Board

Magnetic Inductive Flowmeter EP / UMF2 (B)

MULTICAL 602. & ULTRAFLOW 14 Cooling. Cooling meter with unlimited communication

Datasheet. Multical 402. (Heating & Cooling) Supplied by. .com. Call us on +44 (0)

Uninterruptible Power System

Automated Precision Weighing

Type Electronic Limit Switch

Model TUR-200D Turbine Flowmeter

Special voltages: Voltage >500 V AC are only permissible with external control box. 3-phase AC Voltages/frequencies. 1-phase AC Voltages/frequencies

ProMinent S i g m a / 3 Motor Diaphragm Metering Pumps

CONTOIL VZFA/VZOA , versions for higher requirements / applications

CONA -control Monitoring system for steam traps

Technical Data Sheets

Electronic Limit Switch Type

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control. Benefits.

T O PA S Applications Features Your benefits

Transcription:

APPLICATION Static ultrasonic water meter for accurate measuring and recording for all applications of water supply. FEATURES 4 Real data communication, open metering telegram 4 Long-term stability under difficult conditions 4 Unlimited system capability 4 Leak detection 4 Higher performance than class D requirements 4 No calming sections required 4 No measurement of air 4 Insensitive against sedimentation 4 Mounting in any installation position, battery lifetime up to 16 years 4 Suitable for outdoor installation 4 Displaying of error and alarm codes 4 No over-run perfomance 4 No magnetic influence 4 Data logger for consumption values

GENERAL Medium temperature range C 1... 50 Temperature safety (medium) C 1... 90 Ambient operating temperature C 1... 70 Ambient storage temperature C -20... +70 (>35 C max. 4 weeks) Nominal pressure PN bar 16 Power supply One or two 3.6 VDC lithium batteries (second battery not possible at M-Bus) Battery lifetime Up to 12 years (one battery), up to 16 years (two batteries) Interfaces Optical, radio 434 or 868 MHz, M-Bus, L-Bus, pulse Data storage For events and for consumption values Protection class IP 68 TECHNICAL DATA DISPLAY Display indication LCD, 8-digit Units DN 15 - DN 32 Flow and volume (m³ + 3 digits after the comma) Units DN 40 + DN 50 Flow (m³ + 3 digits after the comma); Volume (m³ + 2 digits after the comma) Values displayed (depending on configuration) 1 : Display according to approval (always on) Volume 1 - flow - mediums temperature - display test 1 - current error and alarm status 1 - date - primary and secondary address - radio signal ON/OFF - battery lifetime 1 - accounting day - error hour counter - pulse values - software checksum 1 INTERFACES - OVERVIEW Optical For configuration of display and radio telegram, to switch to the various displays Radio 434 or 868 MHz, real data telegram (configurable), Open Metering Standard M-Bus 2400 Baud (adjustable to 300 Baud), configurable telegram, cable length 1.5 m Pulse (Open collector) Two configurable pulse outputs, cable length 1.5 m VOLUME- / PULSE OPEN COLLECTOR Max. frequency Hz 20 Max. input voltage V 30 Max. input current ma 27 Max. voltage drop at active output V/mA 2/27 Max. current through inactive output μa/v 5/30 Max. reverse voltage without destroying outputs V 6 Min. pulse duration ms 25 (at max. frequency of 20 Hz) Min. pulse pause ms 25 28.05.2014 2

DN 15-20 TECHNICAL DATA* Nominal flow rate Q 3 m³/h 1.6 1.6 1.6 1.6 1.6 2.5 2.5 Nominal diameter DN mm 15 15 15 20 20 15 15 Overall length L mm 110 165 170 130 190 110 165 Overload flow rate Q 4 m³/h 2 2 2 2 2 3.125 3.125 Transition flow rate Q 2 l/h 10.24 10.24 10.24 10.24 10.24 16 16 Minimum flow rate Q 1 l/h 6.4 6.4 6.4 6.4 6.4 10 10 Starting flow rate l/h 1.3 1.3 1.3 1.3 1.3 2.6 2.6 Pressure loss at Q 3 bar 0.6 0.6 0.6 0.6 0.6 0.33 0.33 Nominal flow rate Q 3 m³/h 2.5 2.5 2.5 4 4 4 Nominal diameter DN mm 15 20 20 20 20 20 Overall length L mm 170 130 190 130 175 190 Overload flow rate Q 4 m³/h 3.125 3.125 3.125 5 5 5 Transition flow rate Q 2 l/h 16 16 16 25.6 25.6 25.6 Minimum flow rate Q 1 l/h 10 10 10 16 16 16 Starting flow rate l/h 2.6 2.6 2.6 4.3 4.3 4.3 Pressure loss at Q 3 bar 0.33 0.25 0.25 0.3 0.3 0.3 * at dynamic range R 250 APPROVAL DN 15-20 Approval MID LNE 14586, OIML R49, EN 14154, TVO, KTW, ACS Dynamic range (Q 3/Q 1) - Q 31.6 m³/h R 160 / 200 / 250 Dynamic range (Q 3/Q 1) - Q 32.5-4 m³/h R 160 / 200 / 250 / 315 / 400 PULSE INTERFACE - SPECIFICATION DN 15-20 Pulse rates l/pulse Decadic 0.1... 100 Display 3 digits after comma Pulse value 1 l/pulse 0.1 (factory setting) Pulse value 2 l/pulse 1 (factory setting) Pulse variants Two forward pulses; pulse and direction signal Note: In the field the pulse values can be configured as desired in the specified value range. 28.05.2014 3

DN 15-20 DIMENSIONS Nominal flow rate Q 3 m³/h 1.6 1.6 1.6 1.6 1.6 2.5 2.5 Nominal diameter DN mm 15 15 15 20 20 15 15 Overall length L mm 110 165 170 130 190 110 165 Counter length L1 mm 88 88 88 88 88 88 88 Counter width B mm 94 94 94 94 94 94 94 Overall length with coupling L2 mm 186 240 245 225 290 186 240 Connection thread on meter Inch G¾B G¾B G¾B G1B G1B G¾B G¾B Connection thread of coupling Inch R½ R½ R½ R¾ R¾ R½ R½ Height H1 mm 67 67 67 65 65 67 67 Weight without coupling (approx.) kg 0.8 1 1 0.9 1.1 0.8 1 Weight with coupling (approx.) kg 1 1.4 1.4 1.3 1.5 1 1.4 Height H mm 32 32 32 34 34 32 32 Nominal flow rate Q 3 m³/h 2.5 2.5 2.5 4 4 4 Nominal diameter DN mm 15 20 20 20 20 20 Overall length L mm 170 130 190 130 175 190 Counter length L1 mm 88 88 88 88 88 88 Counter width B mm 94 94 94 94 94 94 Overall length with coupling L2 mm 245 225 290 225 295 290 Connection thread on meter Inch G¾B G1B G1B G1B G1¼B G1B Connection thread of coupling Inch R½ R¾ R¾ R¾ R1 R¾ Height H1 mm 67 65 65 65 65 65 Weight without coupling (approx.) kg 1 0.9 1.1 0.9 1.1 1.1 Weight with coupling (approx.) kg 1.4 1.3 1.5 1.3 1.7 1.5 Height H mm 32 34 34 34 34 34 28.05.2014 4

DN 15-20 PRESSURE LOSS GRAPH / TYPICAL ERROR GRAPH Pressure loss graph Typical error graph 28.05.2014 5

DN 25-50 TECHNICAL DATA* Nominal flow rate Q 3 m³/h 6.3 6.3 6.3 10 10 10 10 Nominal diameter DN mm 25 25 32 25 25 32 40 Overall length L mm 175 260 260 175 260 260 200 Overload flow rate Q 4 m³/h 7.87 7.87 7.87 12.5 12.5 12.5 12.5 Transition flow rate Q 2 l/h 50.4 50.4 50.4 80 80 80 80 Minimum flow rate Q 1 l/h 31.5 31.5 31.5 50 50 50 50 Starting flow rate l/h 10 10 10 10 10 10 16 Pressure loss at Q 3 bar 0.25 0.25 0.25 0.55 0.55 0.55 0.1 Nominal flow rate Q 3 m³/h 10 16 16 16 16 25 25 Nominal diameter DN mm 40 40 40 50 50 50 50 Overall length L mm 300 200 300 270 300 270 300 Overload flow rate Q 4 m³/h 12.5 20 20 20 20 31.25 31.25 Transition flow rate Q 2 l/h 80 128 128 128 128 200 200 Minimum flow rate Q 1 l/h 50 80 80 80 80 125 125 Starting flow rate l/h 16 16 16 25 25 25 25 Pressure loss at Q 3 bar 0.1 0.24 0.24 0.1 0.1 0.25 0.25 * at dynamic range R 200 APPROVAL DN 25-50 Approval MID LNE 14586, OIML R49, EN 14154, TVO, KTW, ACS Dynamic range (Q 3/Q 1) - Q 36.3 m³/h R 40 / 80 / 160 / 200 Dynamic range (Q 3/Q 1) - Q 310 m³/h R 40 / 80 / 160 / 200 / 250 Dynamic range (Q 3/Q 1) - Q 316 m³/h R 40 / 80 / 160 / 200 / 250 / 315* / 400* Dynamic range (Q 3/Q 1) - Q 325 m³/h R 40 / 80 / 160 / 200 / 250 / 315 / 400 * not for DN 50 PULSE INTERFACE - SPECIFICATION DN 25-50 Pulse rates l/pulse Decadic for DN 25, DN 32, DN 40 (1... 1000), decadic for DN 50 (10... 1000) Display 2 digits after comma Pulse value 1 l/pulse 10 (factory setting) Pulse value 2 Direction (factory setting) Pulse variants Pulse and direction signal Note: In the field the pulse values can be configured as desired in the specified value range. 28.05.2014 6

DN 25-50 DIMENSIONS Nominal flow rate Q 3 m³/h 6.3 6.3 6.3 10 10 10 10 Nominal diameter DN mm 25 25 32 25 25 32 40 Overall length L mm 175 260 260 175 260 260 200 Counter length L1 mm 92 92 92 92 92 92 92 Counter width B mm 94 94 94 94 94 94 94 DIMENSIONS - THREAD....... Overall length with coupling L2 mm 295 380 380 295 380 380 340 Connection thread on meter Inch G1¼B G1¼B G1½B G1¼B G1¼B G1½B G2B Connection thread of coupling Inch R1 R1 R1¼ R1 R1 R1¼ R1½ Height H1 mm 84 84 84 84 84 84 87 Weight without coupling (approx.) kg 1.29 1.6 1.8 1.29 1.6 1.8 2.4 Weight with coupling (approx.) kg 1.89 2.2 2.4 1.89 2.2 2.4 3.6 DIMENSIONS - FLANGE....... Flange diameter D mm - 115 140-115 140 - Hole circle diameter K mm - 85 100-85 100 - Number of screwholes pcs - 4 4-4 4 - Screwhole diameter D1 mm - 14 18-14 18 - Height H mm - 50 62.5-50 62.5 - Height H mm 26 26 26 26 26 26 31 Height H1 mm - 84 84-84 84 - Width F mm - 100 125-100 125 - Weight with flanges (approx.) kg - 3.45 4.7-3.45 4.7-28.05.2014 7

DN 25-50 Nominal flow rate Q 3 m³/h 10 16 16 16 16 25 25 Nominal diameter DN mm 40 40 40 50 50 50 50 Overall length L mm 300 200 300 270 300 270 300 Counter length L1 mm 92 92 92 92 92 92 92 Counter width B mm 94 94 94 94 94 94 94 DIMENSIONS - THREAD....... Overall length with coupling L2 mm 440 340 440 390-390 - Connection thread on meter Inch G2B G2B G2B G2½B - G2½B - Connection thread of coupling Inch R1½ R1½ R1½ R2 - R2 - Height H1 mm 87 87 87 90-90 - Weight without coupling (approx.) kg 3.05 2.42 3.05 3.9-3.9 - Weight with coupling (approx.) kg 4.25 3.62 4.25 5.5-5.5 - DIMENSIONS - FLANGE....... Flange diameter D mm 148-148 163 163 163 163 Hole circle diameter K mm 110-110 125 125 125 125 Number of screwholes pcs 4-4 4 4 4 4 Screwhole diameter D1 mm 18-18 18 18 18 18 Height H mm 69-69 73.5 73.5 73.5 73.5 Height H mm 31 31 31 41-41 - Height H1 mm 87-87 90 90 90 90 Width F mm 138-138 147 147 147 147 Weight with flanges (approx.) kg 6.67-6.67 7.23 7.47 7.23 7.47 PRESSURE LOSS GRAPH / TYPICAL ERROR GRAPH Pressure loss graph Typical error graph 28.05.2014 8