INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Similar documents
INSTALLATION, OPERATION AND MAINTENANCE MANUAL

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Low Pressure Fluid Filters

DFA Series. Rainwater/Graywater Filtration Systems. Installation, Operation and Maintenance Manual DFM-2F-180 DFM-3F-180 DFM-3F-350

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES

TITAN FLOW CONTROL, INC.

MetroPrime 22MPC Self-Priming Centrifugal Pump

3M Housings CH Series

TITAN FLOW CONTROL, INC.

DeZURIK 2 20" BOS BUTTERFLY VALVES

Instruction Sheet SRSR SERIES. Rotating Sliding Rail System

Manufacturing Facility is ISO9001:2000. Welded Steel Pipe Conform to ASTM A53. Threads Conform to ASME B1.20.1

STAINLESS STEEL FORGED FITTINGS 3000lb 304/304L & 316/316L Forged Stainless Steel Fittings Product Specifications

ECONOMAIR SERIES CYLINDERS

Dual/Triple Manifold Water Filtration Systems Instruction Manual

FOLD N STORE. Table Tennis Table. Assembly Instructions Model , DS, DS CONTACT INFO Hours.

Instruction Sheet DWRSR-ZL. Zero Clearance Latch

Model P-40 & Model P-25 POWER PUSHER

FOLD N STORE. Table Tennis Table. Assembly Instructions Model DS, DS CONTACT INFO Hours.

PFS Rotameter. Variable Area Flowmeter. Instruction Manual PFS-RM200, RM230, RM250

DeZURIK 24 and Larger BHP High Performance Butterfly Valves WITH (FB) FYRE-BLOCK SEAT

OWNER S MANUAL Z SERIES TRACKS. Rev. 355_05

Lubricator Gun: 10,000 psi (700 bar) Maximum Delivery Pressure when disconnected from Dispenser

OWNER S MANUAL. LOEGERING th Street SE Casselton, ND USA Fax:

Scale Feeder Manifold Water Filtration System Instruction Manual

3 Station Bike Rack Organization Center

GRINNELL Model B302 and Model BN302 Grooved End Butterfly Valves with Gear Operators or Lever-Lock Operators General Description

Installation Instructions Receiver Rack (Part # 7700) Universal Application

AVK SERIES 41 SWING CHECK VALVE FIELD MAINTENANCE AND INSTRUCTION MANUAL FOR SWING CHECK VALVES 3" - 12"

CLIF MOCK TM. Model 5030 Orifice Fitting. User Manual. Manual No , Rev. B

Operating and Installation Instructions

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES

Dual Flow Manifold Systems Instruction Manual

L DODGE CUMMINS MK-2 + BLK APPS Mount

DODGE CUMMINS Arctic-Heat Grid Relocation Kit

Installation, Operating & Maintenance Instructions. Series 081, DN (I.D. 2½" - 4") Hot surfaces; do not touch!

APCO CVS-6000 CONVERTIBLE SWING CHECK VALVES

Pneumatic Cylinder 14 Bore X 22 Stroke Part No. R (Formerly P )

MODEL 200 MULTI-JET FLOW METER

Colt Series C400, C500

Installation Instructions GOOSENECK MOUNTING KIT Chevrolet/GMC 1500/2500/3500 All except 4-door Crew-Cab

Dual Port Manifold Water Filtration Systems Instruction Manual

Nilfisk-CFM SS Vapor Vacuum Instructions for Use and Spare Parts Manual

WJ-Series. Turbine Meter Instructions ISO. 6 Meter. 3 Meter. Precision Flow Measurement. An ONICON Brand 9001:2008. if ie

LUBRICATOR GUN INSTRUCTIONS-PARTS LIST. 10,000 psi (700 bar) Maximum Delivery Pressure. Detachable-type

Nor East. Instructions Safety Messages. Inspection. Parts. DeZURIK Service. Type 05 Pneumatic Actuator Used With Globe Valves

GA Industries, LLC 9025 Marshall Road Cranberry Township, PA USA Telephone (724) Fax (724)

MODEL L/R/EF Sectional Tire Spreader

Installation, Operation & Service Manual. PPL Bag Filter Housings. Table of Contents Page No. Eaton Filtration, LLC

Pneumatic Cylinder 14 Bore X 21 Stroke Part No. P Replaces Part No. P

DODGE CUMMINS GDP Twin CP-3 Big Line Kit

DeZURIK 2-24 (50-600mm) KGC ES or HD KNIFE GATE VALVES

APCO CVS-250/250A SWING CHECK VALVES

Model AS-RC3260 TV Cart. Rolling Cart for Audio Mount System & Flat Panel TVs

APCO SRG-6500 SURGE RELIEF GLOBE VALVES

DeZURIK KUL KNIFE GATE VALVES

Spray Nozzle Adapters

MODEL 200 MULTI-JET FLOW METER

Air Control Kit INSTRUCTIONS-PARTS LIST. Table of Contents HIGH VOLUME. 250 psi (1.7 MPa, 17.2 bar) Maximum Air Inlet Pressure

MODEL 900 IMPELLER-TYPE FLOW METER

Installation Instructions SRC Over-Size Tire Carrier Jeep Wrangler/Unlimited Part # 2743

AVK SERIES 41 SWING CHECK VALVE FIELD MAINTENANCE AND INSTRUCTION MANUAL FOR SWING CHECK VALVES 3" - 12"

RSV16 Retro-Fit Cartridge Acorn Controls SV16 Valve Cartridge

Service Guide JATCO Environmental Protection Tank Model J-7000

DeZURIK 2-24 (50-600mm) KGN-RSB BI-DIRECTIONAL CAST STAINLESS STEEL KNIFE GATE VALVES

Pro Shot Grease Dispense Valve

Pellicon 2 and 3 Mini Holder. User Guide

CBR lv. Prizelawn COMMERCIAL BROADCAST SPREADER MODEL CBR IV MODEL CBR IVSS. Part# OWNER S MANUAL

DODGE CUMMINS GDP Big Line Kit

½ DODGE CUMMINS OEM BYPASS LIFT PUMP KIT Installation Instructions Part #

ADJUSTABLE COMFORT ASSEMBLY INSTRUCTIONS

Installation Instructions

Val-Matic Air / Oil Hydraulic Panel Pump Control System. Operation, Maintenance and Installation Manual

INSTALLATION AND OPERATING MANUAL

Tiller Lock Assembly

SUPPLEMENTAL MANUAL FOR THE INSTALLATION, OPERATION AND MAINTENANCE OF THE XL234 FILTER VESSEL

PARTS AND INSTALLATION MANUAL


7.3L Ford PowerStroke

MODEL G300 BRAKE BLEEDER

DODGE CUMMINS Air-Boss CR Intake Plenum

Installation Instructions

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

Installation Instructions

PNEUMATIC PIPING DEVICES Service Information

Sample Pro 3/4" Portable MicroPurge Pump. User's Guide P/N REV The World Leader in Air Powered Pumps

MULTIPOSITION AIR CYLINDER

THD-2-FM CONTROLAIR VALVE

HOW TO INSTALL YOUR BOV

HATCHGRIP Installation Instructions/Operation and Maintenance Manual

USER MANUAL. NEMA 48C Flange Mounted, Enclosed, Clutch Brake. FMCBE Model 500 FORM NO. L A (i)

APCO ACS-1200/1700 COMBINATION SLOW CLOSING AIR/VACUUM VALVE

Air-Boss VP Intake Plenum

Using the power override wire. LED Interior Light System (Optional) Adjusting the shelves: TIPS:

DeZURIK 24" THRU 36" RESILIENT BUTTERFLY VALVES

PCC O P E R A T I O N S. Pump Cycle Counter M A N U A L. Environmental Systems

1 2-Inch Station Outlet Valves

Transcription:

PAGE: 1 of 6 INSTALLATION, OPERATION AND MAINTENANCE MANUAL ROSEDALE PRODUCTS, INC. DUPLEX MODEL 4 150 PSIG RATED FILTER UNIT Table of Contents I. Installation....................................................................... 2 II. Operation........................................................................ 3 III. Spare Parts List................................................................... 4 IV. Spare Parts Diagram............................................................... 5 Rosedale Engineering Standards are the property of A Rosedale standard or copy thereof shall not be distributed (except with express approval of Rosedale

PAGE: 2 of 6 I. Installation Please remove all shipping and crating materials carefully. Be sure to remove the plugs from the inlet and outlet openings. Dispose of all crating materials safely. After positioning the Model 4 Duplex Filter unit in its proper location, secure the adjustable tripod leg assemblies to the floor or platform. (Some installations may not require the adjustable tripod leg assemblies.) The duplex system is normally supplied with the inlet-outlet connections in a horizontal orientation (facing in opposite directions) as shown on the last page of this manual. However, the inlet-outlet orientations can be varied depending on your application. The inlet service line should be connected to the inlet flange or NPT coupling located near the top of the units (above basket level). The outlet service line should be connected to the outlet flange or NPT coupling, located near the middle or bottom of the units (below basket level). There are two 1/4" NPT ports, one on the inlet tee and one on the outlet tee, of the Model 4 Duplex Filter unit. Additionally, there is one 1/4" NPT port in each cover of the Model 4 Duplex Filter unit. These ports can remain plugged or used for pressure gauges, or special fittings as your application requires. Some installations require electrical grounding of all equipment, be sure to provide adequate grounding where necessary. After completing installation be sure to double check connections for integrity. Your Model 4 Duplex Filter unit has been factory pressure tested leak free, therefore, any seepage problems usually occur from improper installation connections. You are now ready to install the filter baskets and bags. (Your Rosedale Model 4 Duplex Filter unit consists of two Rosedale Model 4 Filter units. They are designed for continual flow through one unit while servicing the other). Remove cover by loosening the cover eyenuts on one of the filters. The eyenuts in the slotted corners should be loosened sufficiently to swing free. Loosen the third eyenut sufficiently to allow the top cover and closure assembly to swing away from the top of the unit. Place the basket into the filter housing, make sure the basket flange is firmly seated on top of the basket collar. Insert bag into the bag basket making sure filter bag ring is firmly seated on top of the basket flange. For best results, be sure filter bag is installed fully extended to the bottom of the basket. Before replacing cover assembly, inspect cover seal gasket (replacing as necessary). Close cover and alternately tighten the three clamp assemblies evenly to ensure a leak proof seal between the cover and housing body. The ft-lbs recommended torque value for 1/2"-13 closure assemblies is 30-45. Repeat the above steps for installing the filter basket and bag for the other unit. Your Rosedale Model 4 Duplex Filter unit is now ready for operation! Rosedale Engineering Standards are the property of A Rosedale standard or copy thereof shall not be distributed (except with express approval of Rosedale

PAGE: 3 of 6 II. Operation Filter System Start-Up Procedure: Prior to turning on the flow to the inlet service, please make the following checks: 1. Check inside filter unit to be sure basket and filter bag (if applicable) are in housing and do not require cleaning or replacement. If necessary install a clean filter basket and bag (if applicable). 2. Check that filter unit cover is securely fastened to housing. You are now ready to open the flow to the inlet service line. Slowly open the inlet service line approximately 25% of normal operational flow (open slowly as not to displace filter bag inside the housing). After filter unit is pressurized and vented, slowly open outlet service line unit valve until completely open. Complete opening of inlet service line until desired flow rate is reached. Once the desired service flow has been established, the filter will operate efficiently until dirty. However, under no circumstances should more than 15 PSI Differential Pressure through the filter be obtained. Operating the filter unit with a high differential may cause filter bags to rupture and/or cause damage to filter system and downstream equipment. To prevent excessive drop through the filter unit, regular inspection of the filter media is required. Monitoring of differential pressure through the housing can be utilized as a means of determining whether or not the filter media needs cleaning or replacement. Filter Media Cleaning/Replacement Procedure (Side of duplex not in service): The duplex system features continuous filtering capabilities. When it becomes necessary to clean or replace filter media during continuous operating conditions, follow the procedure outlined below: 1. Open balancing valve, if applicable, to equalize pressure in both housings. 2. Unlock mechanical valve actuator assembly by removing the lynch pin. 3. Slowly move the mechanical valve actuator lever 90( to divert the flow to the clean filter vessel. 4. Replace lynch pin to prevent accidental switching of fluid flow to filter being serviced. 5. Close balancing valve, if applicable. 6. Relieve the pressure from the filter vessel being serviced. WARNING CONTENTS UNDER PRESSURE Relieve Pressure in accordance with Manufacturer s instructions before opening Filter Vessel. FAILURE TO DO SO MAY RESULT IN SERIOUS BODILY INJURY. 7. Drain housing sufficiently to access filter basket. 8. Remove cover by loosening the cover eyenuts. The eyenuts in the slotted corners should be loosened sufficiently to swing free. Loosen the third eyenut sufficiently to allow the top cover and closure assembly to swing away from the top of the unit. 9. Remove filter basket and clean thoroughly, remove the filter bag (if applicable) and throw away. Rosedale Engineering Standards are the property of A Rosedale standard or copy thereof shall not be distributed (except with express approval of Rosedale

PAGE: 4 of 6 (Cleaning and reusing the filter bag is not recommended.) 10. Remove debris and sludge from inside the inlet portion of housing to avoid interference with cover seal or flow of fluid being filtered. 11. Remove basket seal (if applicable) and inspect, replace if necessary. 12. Install clean filter basket and filter bag (if applicable). Place the basket into the filter housing, make sure the basket flange is firmly seated on the basket collar. If applicable, insert bag on top of the bag basket flange making sure filter bag ring is firmly seated inside the basket flange. For best results, be sure filter bag is installed fully extended to the bottom of the basket. 13. Inspect cover gasket for cuts or other signs of failure and make sure it is properly seated. 14. Move cover back into position, and alternately tighten the three clamp assemblies evenly to ensure a leak proof seal between cover and housing body. The recommended torque value for 1/2"-13 closure assemblies is 30-45 ft-lbs. Your Rosedale Model 4 Duplex Filter unit is now ready for continuous operation during the next filter media cleaning/replacement maintenance cycle. III. Spare Parts List Your Rosedale Model 4 Duplex Filter unit will give you many years of reliable service provided periodic inspections are made of various components and replacement of worn parts are made promptly. The following is meant to be a recommended spare parts list, these parts are illustrated on the following page. SPARE PARTS LIST Balloon Description Part Number Time-Frame 1 Cover Seal 4300CG-* as needed 2 Basket Seal 4BG-* as needed 3 Cover 4*300 as needed 4 Eye Nut 4ENNI as needed 5 Rod End 4RENI as needed 6 Clevis Pin Assembly 4CPNI as needed 7 Filter Bag (See Order) as needed 8 Filter Basket (See Order) as needed 9 Tripod Legs 4T14*S as needed 10 Duplex Valve Package D#** as needed * Select Material Designation: C=Carbon Steel B=Buna N S=304 Stainless Steel E=Ethylene Propylene S316=316 Stainless Steel V=Viton TEV=Teflon Encapsulated Viton # Select Valve Size: 2-3-4-6-8-...-14 TSW=Teflon Solid White Rosedale Engineering Standards are the property of A Rosedale standard or copy thereof shall not be distributed (except with express approval of Rosedale

PAGE: 5 of 6 IV. Spare Parts Diagram Rosedale Engineering Standards are the property of A Rosedale standard or copy thereof shall not be distributed (except with express approval of Rosedale

PAGE: 6 of 6 Important Notice Warranty: In the event any filtration product is found to be defective in material, workmanship, or not in conformance with any express warranty for a specific purpose, Rosedale s only obligation and your exclusive remedy, shall be to repair, replace or refund the purchase price of such parts or products upon timely notification thereof and substantiation that the product has been stored, maintained and used in accordance with Rosedale s written instructions. EXCLUSIONS TO WARRANTY: THIS WARRANTY IS EXCLUSIVE AND IS IN LIEU OF ANY IMPLIED WARRANTY OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE OR OTHER WARRANTY OF QUALITY, EXCEPT OF TITLE AND AGAINST PATENT INFRINGEMENT. LIMITATION OF LIABILITY: Except as provided above, Rosedale shall not be liable or responsible for any loss or damage, whether direct, indirect, incidental, special or consequential, arising out of sale, use or misuse of Rosedale filtration products, or the user s inability to use such products. THE REMEDIES SET FORTH HEREIN ARE EXCLUSIVE. 3730 West Liberty Road USA 734-665-8201 800-821-5373 Fax. 734-665-2214 Email: filters@rosedaleproducts.com http://www.rosedaleproducts.com Rosedale Engineering Standards are the property of A Rosedale standard or copy thereof shall not be distributed (except with express approval of Rosedale