SEries 41 check valve installation, operation & maintenance manual

Similar documents
Installation Operation Maintenance

AVK SERIES 854 BALL FLOAT VALVE FIELD MAINTENANCE AND INSTRUCTION MANUAL FOR BALL FLOAT VALVES

Swing Check Valves - Series 41

MUELLER ECCENTRIC PLUG VALVE

A. This Section includes general duty valves common to several HVAC piping systems.

Installation Operation Maintenance

TABLE OF CONTENT. 7-Operating mechanisms of Non-return valve with hydraulic damping cylinder

SECTION VALVES

Operating Instructions ROCO Butterfly Valve with SKG Slider-crank Mechanism, with Electric Multi-turn Actuator

Flow Control. Before installation or maintenance, these instructions must be fully read and understood.

SECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING

RESILIENT SEATED GATE VALVE FAF 6200

SECTION VALVES PART 1 - GENERAL

SECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING

PROJECT TITLE : LUSAIL EXPRESSWAY PROJECT CODE : (2012/18) P-003

AVK SERIES 41 SWING CHECK VALVE FIELD MAINTENANCE AND INSTRUCTION MANUAL FOR SWING CHECK VALVES 3" - 12"

MODEL 106/206-PG POWER OPERATED GLOBE VALVE Sizes 1/2" to 8" (106-PG) 3" to 10" (206-PG) Installation, Operating and Maintenance Instructions

Herpteraium SECTION VALVES GENERAL

KEYSTONE Figure 990/991 Butterfly valves Installation, operation and maintenance instructions

AVK SERIES 41 SWING CHECK VALVE FIELD MAINTENANCE AND INSTRUCTION MANUAL FOR SWING CHECK VALVES 3" - 12"

OPTIMAL VALVE SOLUTIONS FOR OIL AND GAS PLANTS

KTM Hindle Series 300 Ultra-Seal two piece metal seated ball valves Installation and Maintenance Instructions

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

SWING CHECK VALVES SERIES 52-SC SERIES 600

Operating Instructions

USER INSTRUCTIONS. Kämmer SmallFlow - Series / Low and Micro Flow Valves. Installation Operation Maintenance. Experience In Motion

INSTALLATION, OPERATION & MAINTENANCE MANUAL. 0.- Description Handling Installation Actuators Maintenance...

Dura Gas Butterfly Valve

CUSTOM COMBINATION AIR VALVE

series BUTTERFLY VALVE DOUBLE ECCENTRIC FLANGED FAF 3800 PRODUCTION STANDARDS DN100 DN2000 PN Design EN 593 EN ISO Flanged

Michigan State University Construction Standards. GENERAL-DUTY VALVES FOR PLUMBING PIPING Page

AWWA C504. Double Eccentric AWWA C504

FRP Ball Valves INSTALLATION & MAINTENANCE MANUAL

BCV30 DN20 - Blowdown Control Valve Installation and Maintenance Instructions

Dura Water Wafer Butterfly Valve

AEL6 Series Smart Electric Linear Actuators for DN15 to DN100 Control Valves

AEL6 Series Smart Electric Linear Actuators for DN15 to DN100 Control Valves

PN9000 Series Pneumatic Actuators Installation and Maintenance Instructions

Mounting and Operating Instructions EB 8111/8112 EN. Series V2001 Valves Type 3321 Globe Valve

INSTALLATION, OPERATION & MAINTENANCE MANUAL MODEL BC.

Tilting-disc Check Valves Short Body

26 Series Stainless Steel 2-way Ball Valves

QLM and QLD Series DN125 to DN200 Three Port Control Valves

BUTTERFLY VALVE WITH WELDED ENDS INSTALLATION AND MAINTENANCE MANUAL

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

740G Double Disc Check. Valve. Operation / Maintenance Manual. General Information 2. Installation/Operation 3

AVK SERIES 55 AND 06 GATE VALVES, DN 450/500/600


INSTALLATION, OPERATION & MAINTENANCE MANUAL Description Handling Installation Actuators...

Standard Valves Series Globe Valves Series Angle Valves Series Way-Valves

Installation, Operation and Maintenance Guide II NIBCO High Performance Butterfly Valves Series 6822 and 7822

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

FASANI ASSISTED SWING CHECK VALVE BOLTED BONNET INSTALLATION AND MAINTENANCE INSTRUCTIONS

INSTALLATION, OPERATION AND MAINTENANCE MANUAL OF KNIFE GATE DURGA VALVES PVT. LTD. ICHAPUR ROAD, CANAL SIDE, SANTRAGACHI, HOWRAH

'C' Series Control Valves

2-12 Grooved End Dual Disc Check Valve. Operation, Maintenance and Installation Manual

DN15 DN250 PN 16. Corrosion Protection

Ideal Installation. I & M Mark 67 (1/2 6 ) Control Line. Installation & Maintenance Instructions for Mark 67 Pressure Regulators

Installation Operation Maintenance. LSSN Butterfly Valve AGA Approved 50MM - 150MM. QAD#IM6055.REVA

ROM Series. Keeping the World Flowing. Installation Manual. Valve Actuators

SECTION GENERAL-DUTY VALVES FOR HVAC. A. Section includes valves for building services piping.

740G Double Disc Check Valve

GBV-G Balancing Valves

Water Supply and Sewerage Approved Products Manual - February 2006

VALVCHEQ BACKFLOW PREVENTERS FIGURE DC03

Fisher 3024C Diaphragm Actuator

AEL5 Series Electric Linear Actuators

IOM Manual. IOM Manual. Series 76/77.

SECTION (15110) - GENERAL DUTY VALVES FOR PLUMBING PIPING

720A Wafer & 821A Globe Style

OPERATION AND MAINTENANCE MANUAL 2-66 SERIES 2500 RESILIENT WEDGE GATE VALVE

Technical changes kept in reserve INSTALLATION, OPERATION & MAINTENANCE MANUAL. 0.- Description Handling Installation...

Size : Ends : Min Temperature : Max Temperature : Materials : Cast iron body. Certificate 3.1

Series 820 AWWA Butterfly Valves

QLM and QLD Series DN15 to DN100 Three Port Control Valves

720G Wafer and 821G Globe Style Silent Check Valves

Front mechanical suspensions

EL5600 Series Electric Linear Actuators

Cast Iron Valves. Product Information. It s all at Albion

LC149 SERIES BUTTERFLY VALVE INSTALLATION, OPERATION, & MAINTENANCE

LOWER MACUNGIE TOWNSHIP COMMUNITY CENTER ADDITIONS AND RENOVATIONS

Maintenance Manual Reduced Pressure Assembly Models 860 & 880V 2 1 /2" 10"

Static Balancing Valve

Mounting and Operating Instructions EB 5868/5869 EN

GROOVED END FLO-TREX COMBINATION VALVE

BUTTERFLY VALVE - WAFER FAF 3500

Mounting and Operating Instructions EB 8135/8136 EN. Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil

Iron Check Valves Illustrated Index

Keystone Series GR resilient seated butterfly valves GRW/GRL Installation and operation manual

Installation and Maintenance Instructions for Morin MRP Pneumatic Rack and Pinion Actuators

Installation & Operation Manual

APT14 Automatic Pump Trap Installation and Maintenance Instructions

Double Offset High Performance Butterfly Valve

DeZURIK " BAW AWWA BUTTERFLY VALVES WITH EPOXY-RETAINED SEAT

EL5600 Series Electric Linear Actuators Installation and Maintenance Instructions

Description. Functions. Technical data. Applications. Tests. Level control float valve, enabling the control of the filling level.

Crispin Valves Operating Guide. Crispin

Michigan State University Construction Standards. GENERAL-DUTY VALVES FOR HVAC PIPING Page

Gearbox Installation Manual

ROM Series. Established Leaders in Flow Control. Installation Manual. Valve Actuators

Transcription:

Instruction for use Thank you for selecting an AVK product. With correct use, it will give long and reliable service. This manual has been prepared to assist you install, operate and maintain the valve to the maximum efficiency. For ease of reference, it has been divided into sections covering all aspects of use, and it is in the users best interests to read it and ensure that it is fully understood. Health and Safety It is always recommended that wherever work is being carried out on a valve that the valve is fully depressurised prior to carrying it out, and for the convenience draining of the line may be beneficial. It is essential that the user of the valve is aware of the weight of the components and/or assembles that must be handled and manipulated during installation and maintenance. It is the users responsibility to ensure that safe working practices are followed at all times. Whenever AVK products are installed, operated, or maintained, it is essential that the staff that undertake these operations be adequately trained. The hazards of pressurised liquids and gases can be severe, and it is the responsibility of the users to ensure that trained, competent staff undertake these duties. This manual has been designed to assist, but it can never fully replace quality training in the workplace. AVK technical staff will always be available to answer any questions relating to specific problems that may not be covered by this manual. AVK products are designed and manufactured to be fit for purpose, and to a high and reliable standard. This provides a safe product with minimum risk to health when used correctly for the purpose for which it was designed. However, this assumes that the equipment is used and maintained in accordance with the manual, and the user is advised to study this manual, and to make it available to all staff that may need to refer to it. AVK cannot be held responsible for any incidents arising from incorrect installation, operation or maintenance. The responsibility for this must rest wholly with the user.

Storage The valve should not come into contact with any contaminative substances prior to installation Valve end protectors (if supplied) should not be removed unless necessary for inspection or installation. Protection against weather should be provided. Ideally, valves should be kept indoors with the actual valve temperature always higher than the dew point, particularly for valves fitted with actuators. If outdoor storage is unavoidable the valves should then be supported off the ground and protected by a weatherproof cover, from dust-laden damp or saline conditions and at an ambient temperature. If long term storage is envisaged, then it may be considered prudent to have a AVK engineer inspect the valve prior to installation. Handling A basic consideration in handling protected valves should be to avoid damaging the coating protection and valves should never be thrown or dropped. Valves whose size requires handling by crane or lift truck should be slung or rigged carefully to avoid damage to exposed valve parts. Handwheels, bypass, actuators and gearboxes in particular, should not be used as lifting or rigging points for valves.

1. Introduction The AVK series 41 Swing Check Valves are designed for horizontal or vertical flow (not suitable for down-flow applications). The design permits full bore flow and enables correct alignment of the resilient seated disc to the body seating surface. The valve comes equipped with a bolted bonnet which can be removed while the valve is in the line. Materials: Body and bonnet Ductile Iron to AS 1831 Coating Electrostatically applied epoxy resin to AS 4158 - Internally and externally Shaft Stainless Steel Bonnet gasket EPDM rubber Bushing Copper alloy AS/NZS 1567 Hexagon bolt, washer and pin Stainless Steel Resilient seated disc EPDM rubber with a steel insert Hinge DN 80-200: Stainless steel DN 250-300: Ductile Iron to AS 1831 Accessory kit: Weight, hinge lever and weight Ductile Iron to AS 1831 Cam Stainless Steel

Component list 1. Body 2. Bushing closed 3. Bonnet 4. Hexagon bolt 5. Washer 6. Bushing open 7. Lever 8. Nut 9. Washer 10. Weight 11. Grub screw 12. O-ring 13. O-ring 14. O-ring 15. Shaft 16. Bonnet gasket 17. Tab washer 18. Nut 19. Washer 20. Bushing 21. Hinge 22. Rubber disc 23. Hexagon bolt 24. Shaft protector 25. Connector 26. Key 27. Retaining washer 28. Spacer 1 2 3 4 5 6 7 17 8 9 H 10 11 Dt Dh D ds Lever and weight as optional extras 18 19 20 21 22 23 L 12 13 14 15 25 26 27 28 16 DN80, 100, 150 and 200 24 DN250-300

2. Installation a) When installing the check valves, ensure that the seats and the flange faces are clean. b) When valves are provided with lifting lugs, plates or eye nuts, these must be used to lift the valve. c) To ensure adequate sealing it is important to select the correct type of gasket for the medium concerned, gaskets with the correct flange size must be used. d) Place valve between pipe flanges, and insert the bolts. e) Tighten bolts loosely. f) Tighten bolts in a diagonal sequence to ensure flanges are pulled parallel. g) Finally tighten bolts to correct torque levels as recommended in WSA 109. 2.1. Bolts 2.1.1 Bolt size The following table shows bolt size you should use for which valve dimensions. as 2129 as 2129 table B5 table E table F DN Bolts Quantity Bolts Quantity Bolts Quantity 50 M16 4 M16 4 M16 4 80 M16 4 M16 4 M16 8 100 M16 4 M16 8 M16 8 150 M16 8 M20 8 M20 12 200 M16 8 M20 8 M20 12 225 M16 8 - - - - 250 M16 8 M20 12 M24 12 300 M20 12 M24 12 M24 16 375 M24 12 M24 12 M27 16 400 M24 12 M24 12 M27 20

Horizontal Mounting Front View Direction of Flow Top View Vertical Mounting Direction of Flow Rear View Front View

Lever & weight positions Open Position Direction of Flow Closed Position Horizontal Mounting Open Position Closed Position Direction of Flow Vertical Mounting

3. Operation Series 41 Swing Check Vlaves are suitable for use with wholesome (potable) water and low solids sewage up to 70oC. Minimum liquid temperature must be above freezing. Insulation is recommended for external temperatures from 0oC to -10oC. They can have a Lever & Weight option, Right Hand as standard. Design Constraints Please consider the following points when selecting your valve: Consideration should be given at the design stage where valves will be located to give access for operation, adjustment, maintenance and repair. If a valve is installed less than 5 pipe diameters upstream or downstream of any pump elbow or tee etc., it will experience very high-localised velocities that are far in excess of the average velocity. This high velocity will result in excessive turbulence within the valve and variations in performance may be experienced, therefore installation in this area should be avoided. Valves must be provided with adequate support. Adjoining pipework must be supported to avoid the imposition of pipeline strains on the body which may impair its performance. Full flow is achieved with the disc positioned in the bonnet cavity, this occurs when velocity is greater than 1.5m/s. Velocities above 4.5m/s can result in disc flutter reducing pump efficiencies and reducing the life of the valve. For disc to seal a static pressure differential of a minimum of 70kpa is required.

4. Maintenance The valve is designed for use with minimum maintenance and requires no lubrication. In the event of a spares replacement becoming necessary, the recommended procedure is as follows: SAFETY PRECAUTIONS a) Procedures must NOT be carried out whilst the valve is installed in a live main under pressure. b) Ensure main will NOT be recharged before all work on the valve is completed. 4.1 Replacement of Brass Sealing Bushes with 'O' Ring Seals. Component list 1. Body 2. Bushing closed 3. Bonnet 4. Hexagon bolt 5. Washer 6. Bushing open 7. Lever 8. Nut 9. Washer 10. Weight 11. Grub screw 12. O-ring 13. O-ring 14. O-ring 15. Shaft 16. Bonnet gasket 17. Tab washer 18. Nut 19. Washer 20. Bushing 21. Hinge 22. Rubber disc 23. Hexagon bolt 24. Shaft protector 25. Connector 26. Key 27. Retaining washer 28. Spacer 1 2 3 4 5 6 7 17 8 9 10 11 H Dt Dh D ds Lever and weight as optional extras 18 19 20 21 22 23 L 12 13 14 15 25 26 27 28 16 DN80, 100, 150 and 200 24 DN250-300 This can only be carried out when there is no pressure in the pipeline. a) If fitted remove nut (8), washer (9) and lever (7) with weight (10). NOTE: position of lever relative to body (1) for re-assembly. b) Unscrew either bushing (2) or (6) and replace with new bushing complete with 'O' ring seals. c) Repeat step b) with opposite side bushing. d) Where necessary, refit lever (7), weight (10), washer (9) and nut (8).

4.2 Replacement of Complete Bonnet Assembly (complete with Shaft, Hinge, Disc and Bushings). Component list 1. Body 2. Bushing closed 3. Bonnet 4. Hexagon bolt 5. Washer 6. Bushing open 7. Lever 8. Nut 9. Washer 10. Weight 11. Grub screw 12. O-ring 13. O-ring 14. O-ring 15. Shaft 16. Bonnet gasket 17. Tab washer 18. Nut 19. Washer 20. Bushing 21. Hinge 22. Rubber disc 23. Hexagon bolt 24. Shaft protector 25. Connector 26. Key 27. Retaining washer 28. Spacer 1 2 3 4 5 6 7 17 8 9 10 11 H Dt Dh D ds Lever and weight as optional extras 18 19 20 21 22 23 L 12 13 14 15 25 26 27 28 16 DN80, 100, 150 and 200 24 DN250-300 This can only be carried out when there is no pressure in the pipeline. a) Remove bonnet (3) by removing hexagon screws (4) and washers (5) and lift completed assembly from body (1). (NOTE: Screws are different lengths.) NOTE: If bushings only are to be replaced, follow steps in 4.1. Check free movement of hinge prior to re-assembling of body. a) Ensure that seat area in body is clean. b) Fit hexagon screws (4) and washers (note different lengths) (5) through bonnet (1) and fit bonnet gasket (16) over screws (4). Fit bonnet (3) into body (1) with disc (23) facing correct way. c) Tighten bonnet screws (4) in a diagonal sequence using torque wrench set at 25Nm to 30Nm. Reset the torque Wrench at 40Nm to 50Nm and re-tighten the screws following a circumferential sequence. d) Slowly re-charge the main and check integrity of seals.

4.3 Adding Lever & Counterweight to Series 41 Free End Shaft Valves (DN50 up to DN300). Component list 1. Body 2. Bushing closed 3. Bonnet 4. Hexagon bolt 5. Washer 6. Bushing open 7. Lever 8. Nut 9. Washer 10. Weight 11. Grub screw 12. O-ring 13. O-ring 14. O-ring 15. Shaft 16. Bonnet gasket 17. Tab washer 18. Nut 19. Washer 20. Bushing 21. Hinge 22. Rubber disc 23. Hexagon bolt 24. Shaft protector 25. Connector 26. Key 27. Retaining washer 28. Spacer 1 2 3 4 5 6 7 17 8 9 10 11 H Dt Dh D ds Lever and weight as optional extras 18 19 20 21 22 23 L 12 13 14 15 25 26 27 28 16 DN80, 100, 150 and 200 24 DN250-300 Safety Precaution : This can only be carried out, when there is no pressure in the pipeline. Fitting of the parts: a) Remove shaft protector (24) from free end of shaft (15). b) Attached the lever (7) to the shaft (15) and secure with washer (9) and nut (8). NOTE: The lever (7) must be aligned on the hexagon flats on the shaft (13) to ensure correct closure of the disc (22) and clearance to a guard, if fitted. The alignment is also important with respect to the installation position of the valve, either vertical or horizontal. c) Mount the counterweight (10) onto the lever (7) and lock its position with the set screw (11). (DN250 & DN300 may have more than one counterweight fitted). The weight can be moved on lever to adjust closing speeds. DO NOT adjust weight while system is in operation. d) Re-connect the flow and slowly fill the valve to check for correct operation.

4.4 Assembly of Cam Switch a) Using M5 Tap clean out bracket bolt holes on side of valve body. Ensure that the holes tapped are on the same side as the exposed stem. b) Using an Allen key attach the limit switch bracket to the valve body with 2 x M5 screws. c) Attach limit switch to bracket with 2 x M4 socket head bolts. Ensure flat washer is behind bolt head and spring washer is behind nut. d) With the valve in the fully closed position slide the cam over the valve stem and rotate until switch is engaged. Pull the stem in and out ensuring that it remains in contact with the switch at all times Once positioned correctly apply a small amount of thread locking compound (Loctite 277) to the grub screw and lock the cam into position. e) Check the switch operation ensuring that when the valve is closed the switch remains engaged on the cam. If this does not occur return to step d) and reposition the cam.

4.5 Installation of Proximity Switch a) If not already fitted, fit the standard mechanical switch mounting bracket using two M5 Button Head screws to the side of the valve that the switch will be mounted b) Fit the proximity mounting bracket to the mechanical switch bracket using the two M4 socket screws, nuts and washers. Note: Ensure the screw, washer and bracket arrangement is assembled correctly in the order of socket screw, flat washer, proximity bracket, mechanical switch bracket, spring washer, nut. With the grub screw inserted into the proximity cam mount the proximity cam and grub assembly onto the shaft and positioning it centrally to the aperture of the proximity bracket, lightly tighten the grub screw to clamp the cam in a preliminary position. d) Insert the proximity switch through the mounting bracket and fit the lock nuts. Adjust the proximity switch position in relation to the cam lobe and set the sensing gap to 3mm. Tighten lock nuts to secure the proximity switch in position. Lock the M5 grub screw in the cam to secure the position and check to ensure the cam does not contact with the proximity switch. 3mm e) Fit the lever and weight assembly (if required) to the shaft and secure with the locknut and washer. This completes the proximity switch mounting.